CLADDING PROFILES
Steel building envelope products that add beauty and durability to your designs
Sub-girts............................................................................. 22
Project Gallery.................................................................... 23
BELLARA TM
Mountain Cedar
Our extensive line of Roofing and Cladding products provides you with the choice you desire in
planning your project and the ability to make your vision a reality.
4 www.vicwest.com
HIDDEN FASTENER WALL PROFILES
R - Ribbed SR - No Rib
Exposed side
pre-painted
(Dim.) = mm
AD150 AD200-R
5 29/32” 5 29/32” AD200-R is 7 7/8” 3 15/16”
(150 mm) (150 mm) also available (200 mm) (100 mm)
without
Painted Side stiffener ribs Painted Side
AD200-SR
1 9/16” 1 9/16”
(40 mm) (40 mm)
AD275-R AD300-R
AD275-R is 10 13/16” 1” AD300-R is 11 13/16”
also available (275 mm) (25 mm) also available (300 mm)
without Painted Side without Painted Side
stiffener ribs stiffener ribs
AD275-SR AD300-SR
1 9/16” 1 9/16”
(40 mm) (40 mm)
.59” 96
(15 mm) ˚
96
˚
CHANNELWALL (CAN ONLY BE USED AS A WALL CLADDING) CL508 (CAN ONLY BE USED AS A WALL CLADDING)
CHANNELWALL 32” (813 mm) CL508 is the 32” (813 mm)
is the reverse reverse of 6 3/8” (162 mm)
of CL508 6 3/8” (162 mm) Painted Side CHANNELWALL Painted Side
CL7015-R (CAN ONLY BE USED AS A WALL CLADDING) CL815-R (CAN ONLY BE USED AS A WALL CLADDING)
CL7015-R is 29 3/4” (755 mm) CL815-R is
the reverse of the reverse of 29 3/4” (755 mm)
CL815-R 4 1/4” (108 mm) Painted Side CL7015-R 4 1/4” (108 mm) Painted Side
CL3035 (CAN ONLY BE USED AS A WALL CLADDING) CL435 (CAN BE USED FOR ROOF AND WALLS)
CL3035 is the CL435 is
reverse of CL435 39 31/32” (1015 mm) 39 31/32”
the reverse (1015 mm)
13 5/16” (338 mm) Painted Side of CL3035
Painted Side
1 3/8”
(35 mm)
CLCL3070
3070 (CAN ONLY BE USED AS A WALL CLADDING) CL470 (CAN BE USED FOR ROOF AND WALLS)
CL3070 is the CL470 is 33 7/16”
reverse of CL470 33 7/16” (850 mm)
the reverse (850 mm)
Painted Side of CL3070 Painted Side
2 3/4”
(70 mm)
6 www.vicwest.com
EXPOSED FASTENER PROFILES (continued)
CL - Cladding Lap R - Ribbed SR - No Rib Exposed side
**APPLICATION NOTE: Please consult your Vicwest representative for maximum length recommendations for this product. pre-painted
Exposed fastened roofs should be installed on slopes greater than 3:12. Please consult your Vicwest Representative for slopes lower than 3:12. (Dim.) = mm
CL3100 (CAN ONLY BE USED AS A WALL CLADDING) CL400 (CAN BE USED FOR ROOF AND WALLS)
33 3/32” 33 3/32”
CL3100 is (840 mm) CL400 is
the reverse the reverse (840 mm)
of CL400 Painted Side of CL3100 Painted Side
3 15/16”
(100 mm)
CL5022-SR (CAN ONLY BE USED AS A WALL CLADDING) CL622-R (CAN BE USED FOR ROOF AND WALLS)
CL5022 is the CL622 is the 37 3/8”
37 3/8” (950 mm) (950 mm)
reverse of CL622 reverse of CL5022
7 1/2” (190 mm) Painted Side
Available with Painted Side CL622 is also
stiffener ribs available without
CL5022-R stiffener ribs
CL622-SR
Minimum thickness required for CL5022-SR 1 7/16” Minimum thickness required for CL622-SR 7 1/2”
1 3/8” (35 mm) (36 mm) please contact your Vicwest Sales Representative (190 mm)
please contact your Vicwest Sales Representative
CL6025-SR (CAN ONLY BE USED AS A WALL CLADDING) CL725-R (CAN BE USED FOR ROOF AND WALLS)
CL6025 is the CL725 is
35 7/16” (900 mm) the reverse 35 7/16”
reverse of CL725 (900 mm)
5 7/8” (150 mm) of CL6025
Available with Painted Side
CL725 is also Painted Side
stiffener ribs available without
CL6025-R stiffener ribs
CL725-SR
CL7040 (CAN ONLY BE USED AS A WALL CLADDING) CL840 (CAN BE USED FOR ROOF AND WALLS)
CL7040 is 36 13/16” (935 mm) CL840 is 36 13/16” (935 mm)
the reverse the reverse
of CL840 5 1/4” (134 mm) Painted Side of CL7040 5 1/4” (134 mm) Painted Side
DR30 (CAN ONLY BE USED AS A WALL CLADDING) DR36 (CAN ONLY BE USED AS A WALL CLADDING)
30” (762 mm) 36” (914 mm)
6” (152 mm) Painted Side 6” (152 mm)
Painted Side
CL938 (CAN ONLY BE USED AS A WALL CLADDING) CL439 (CAN BE USED FOR ROOF AND WALLS)
35 7/16” (900 mm) 39 3/8” (1000 mm)
13 1/8” (333 mm) Painted Side
1 1/2”
(38 mm)
5 7/8” 1 3/8” (34 mm) Standard for West region. Please verify the feasibility
(150 mm) with Vicwest for Central, East and Maritime Regions.
8 www.vicwest.com
EXPOSED FASTENER PROFILES (continued)
CL - Cladding Lap R - Ribbed SR - No Rib Exposed side
**APPLICATION NOTE: Please consult your Vicwest representative for maximum length recommendations for this product. pre-painted
Exposed fastened roofs should be installed on slopes greater than 3:12. Please consult your Vicwest Representative for slopes lower than 3:12. (Dim.) = mm
CL4012 (CAN ONLY BE USED AS A WALL CLADDING) GRAND RIB (CAN BE USED FOR ROOF AND WALLS)
CL4012 is 30” (762 mm) Grand Rib is 30” (762 mm)
the reverse the reverse
of Grand Rib 7 1/2” (190.5 mm) of CL4012 7 1/2” (190.5 mm) Painted Side
Painted Side
ULTRAVIC (CAN BE USED FOR ROOF AND WALLS) SUPERVIC (CAN BE USED FOR ROOF AND WALLS)
36” (914 mm)
30” (762 mm)
9” (228.6 mm) Painted Side 10” (254 mm) Painted Side
3/4”
(19 mm)
Hole Size & Spacing % Open Air Hole Size & Spacing % Open Air
10 www.vicwest.com
ROOF SYSTEM PROFILES
NOTE: Minimum roof slope can vary between profiles. Please consult your Vicwest Representative
Exposed side
pre-painted
(Dim.) = mm
1 1/2”
(38 mm)
1 1/2”
(38 mm)
Available in Prestige-SR 16 (without rib)
15 3/4” 17 23/32”
(400 mm) (450 mm)
Painted Side
Painted Side
1 1/2”
(38 mm) 1 25/32”
(45 mm)
Painted Side
2 3/4”
(69 mm)
RD938/RD938-CL/HB938/HB938-CL RD306/RD306-CL/HB306/HB306-CL
Edmonton 35 7/16” Deck Lap Shown Deck Lap Shown
(900 mm) 24” (609 mm)
1 1/2”
(38 mm)
3”
Exposed Surface (76 mm)
5 29/32”
(150 mm) Exposed Surface 6”
(152 mm)
Cladding Lap Shown
RD306-CL used as a prefinished profile. Available only in 18" coverage (not shown).
RDS938/RDS938-CL/HBS938/HBS938-CL Contact your Vicwest representative for additional information.
1 1/2”
(38 mm)
3”
(76 mm)
Exposed Surface Exposed Surface
36” 24” (609 mm)
(914 mm)
12 www.vicwest.com
TRIMS & ACCESSORIES
Exposed side
pre-painted
(Dim.) = mm
REFERENCE
200 Series - CL508/CHANNELWALL, CL7015/815 and 1/2” CORRUGATED
500 Series - SUPERVIC, DIAMOND RIB All flashings/trims are available 10’-0” long.
700 Series - ELITE, 7/8” CORRUGATED Custom flashings to specific requirements are
1100 Series - CL7040/840, CL6025/725, CL5022/622, available upon request.
CL3035/435 and AD150/200/275/300 Please consult your Vicwest representative.
1800 Series - CL3100/400
3000 Series - Generic
Clip Closure
1-1/2”
2-3/8”
(60)
(38)
Minimum
1-1/2” (38)
5/8”
(16)
C
B
C D C D
5/8” 1-1/2” 215 3/4” 5/8” 4-1/4” 2” 2” 1” 3” 3”
207 (16)
1107 (38) (19) (16) (108) (50) (51) (25) (76) (76)
7/8” 2-3/4” 515 1” 1” 2-3/4” 2-1/4”
507 1407 (25) (25) (70) (57)
(22) (70)
1-1/8” 1807 4” 715 1-1/2” 1” 4-3/4” 2-1/4”
707 (29) (102) (38) (25) (121) (57)
C
B
C
* to be specified
B
C
3/4” 3/4” 3”
216 (19) (19) (76)
C C
11/16” 5/8” 2-3/16” 2” 1” 2-1/2” 1-1/8” 3/4” 5-1/4”
220 1120 516 (29) (19) (133)
(17) (16) (56) (51) (25) (64)
1” 1” 2-5/8” 1-1/2” 3/4” 4-1/2”
520 (25) (25) (67) 716 (38) (19) (108)
1-1/2” 1” 3” 2” 3/4” 3-1/2”
720 (25) (76)
1116 (51) (19) (89)
(38)
Drip Drip
A A
C
B
C
* 3/4” (19), 1” (25), 1-1/2” (38), * 3/4” (19), 1” (25), 1-1/2” (38),
2” (51), 3” (76), 3-1/2” (89), 4” (102), 2” (51), 3” (76), 3-1/2” (89), 4” (102),
5” (127), 6” (152), 9” (229) to be specified
* 5” (127), 6” (152), 9” (229) to be specified *
C C
3/4” 3/4” 3/4” 3/4”
217 (19) (19)
+/- 3” (76) 218 (19) (19) +/- 3” (76)
1-1/8” 3/4” 1-1/8” 3/4”
517 (29) (19) +/- 3-1/4” (83) 518 (29) (19) +/- 4” (102)
14 www.vicwest.com
TRIMS & ACCESSORIES (continued)
See REFERENCE on Page 13
Exposed side
pre-painted
(Dim.) = mm
Drip Drip
A
A
C
B
C
B
C C
3/4” 3/4” 2” 3/4” 3/4” 4-1/2”
219 (19) (19) (51) 222 (19) (19) (108)
1-1/8” 3/4” 2-3/4” 1-1/8” 3/4” 3-3/4”
519 (29) (19) (70) 522 (29) (19) (95)
1-1/2” 3/4” 3-1/4” 1-1/2” 3/4” 3”
719 (38) (19) (83) 722 (19) (76)
(38)
2” 3/4” 2-3/4” 2” 3/4” 5”
1119 (51) (19) (70) 1122 (51) (19) (127)
5/8” 5/8”
(16 mm) (16 mm)
DSC-4
DSC-6
B
1” (25)
6” (153)
1” (25)
4” (103)
1” (25)
1-1/2” (38)
4” (103)
)
95
”(
* Specify Angle ‘X’
4
3/
3-
(Req’d. 2’-0” C/Cs)
79535
1/8”
(3)
D
C
C D C D
11/16” 1” 3/4” 2-1/8” 1-5/8” 1” 7/8” 2-1/2” 5/8” 1-3/4”
201 208 1108
(17) (25) (19) (54) 1101 (41) (25) (22) (64) (16) (44)
15/16” 1” 3/4” 1-15/16” 1” 3”
501 (24) (25) (19) (49) 508 (25) 1408 (76)
1 1/8” 1” 7/8” 3” 708 1-1/4” 1808 4-3/16”
701 (29) (25) (22) (76) (32) (106)
Inside Corner
2-1/2”
IN-1 (64)
4”
IN-2 (102)
Walls: 7/8" CORRUGATED Architects:
Waterloo Fire Station, Waterloo, ON alaimo architecture inc.
16 www.vicwest.com
TRIMS & ACCESSORIES (continued)
Exposed side
pre-painted
(Dim.) = mm
Jamb Jamb
C
A
C
A
* 3/4 (19), 1” (25), 1-1/2” (38), 2” (51),
3” (76), 4” (102), 5” (127), 6” (152),
9” (229) to be specified* B
A
C
C
A
B
B
C C
D
C
B
B
C D C D
5/8” 3/4” 2-3/4” 1-7/8” 1-5/8” 1” 3-1/2” 2-3/4” 5/8” 2-3/4” 1-3/4” 3-1/2”
204 (16) (19) (70) (48) 1104 (41) (25) (89) (70) 206 (16) (70) (44) (89)
15/16” 1” 2-3/4” 2-13/16” 1” 2-3/4” 3” 5”
504 (24) (25) (70) (71) 506 (25) (70) (76) (127)
1-1/8” 1” 3-1/2” 2-3/8” 1-1/4” 3-1/2” 4-3/16” 5-1/2”
704 706 (32) (89) (106) (140)
(29) (25) (89) (60)
A A
D
C
2-1/2”
EX-1 (64)
4”
EX-2
B
(102)
C D
Walls: AD300 Vertical, 5/8” 1-1/4” 3/4” 1-3/4”
and TRADITION 100 200 (16) (32) (19) (44)
15/16” 1-3/4” 1” 2-3/16”
Northlands Exposition Centre 500 (24) (44) (25) (56)
Edmonton, AB
1-1/8” 2-1/4” 1” 3-1/4”
Architects: DIALOG 700 (29) (57) (25) (83)
18 www.vicwest.com
TRIMS & ACCESSORIES (continued)
Exposed side
pre-painted
(Dim.) = mm
A
5-3/8” A
FA-6 (136)
8” 2-7/16”
FA-8 (203) To specify FR-6 (62)
11” 3-13/16” To specify
FA-12 (279) FR-8 (97)
A
4-1/2” (114)
To specify
To specify
3” (76)
3/4”(19)
3/4” (19)
To specify
3/4”(19) )
” (140
5-1/2
* 6” (152), 9” (229),
* 9-1/8” (232), 12-1/8” (308) 12” (305), 15” (381)
B
Vicwest Vented Ridge
allows damp warm air to
circulate out of attics that
would otherwise assist in the
deterioration of insulation and roof
structures.
7”
223 3/4” 2-1/2” 1123 2” 5”
(19) (64) (51) (127)
2”
Rows of Total Opening Area 523 1-1/8” 3-3/4”
Perforations per 10’-0” Section 4” 2-3/4” (29) (95)
12-3/4” 723 1-1/2” 3”
4 68.88 sq. ins. (38) (76)
95˚
2-1/2”
(64)
3/4” (19)
C D
A&B
A
* to specify 3002
20 www.vicwest.com
AD300 TRIMS & ACCESSORIES
Exposed side
pre-painted
(Dim.) = mm
2-1/2”
(64)
“J Trim” AD300 Vertical
1-1/2”
(38)
1-3/8”
(29) ADT-C
1-1/8”
(29) 1-1/2”
(38)
C
B
A
No. “X” dimension “Y” dimension “YY” dimension
5/8” 13/16” 1-1/2”
H-62 (16 mm) (21 mm) (38 mm)
3/4” 1” 1-1/2”
H-75 (19 mm) (25 mm) (38 mm)
1” 3/4” 1-1/2”
H-100 (25 mm) (19 mm) (38 mm)
1-1/2” 1-1/16” 1-1/2”
H-150 (38 mm) (27 mm) (38 mm)
C
2” 3/4” 2”
H-200 (51 mm) (19 mm) (51 mm)
2-1/2” 21/32” 2-1/2”
H-250 (64 mm) (17 mm) (64 mm)
* Notched sub-girts are also available.
Vicwest reserves the right to change dimensions, 3” 1-3/8” 3”
(except the “x” dimension), without notice. H-300 (76 mm) (35 mm) (76 mm)
For other lengths and/or dimensions, please consult Vicwest.
22 www.vicwest.com
PROJECT GALLERY
Roof and Exterior Walls: TRADITION 150 Walls: 7/8" CORRUGATED
Interior Walls and Ceiling: AD300-R
Dalhousie University,
Canada 150 Pavillion Life Sciences Building
London, ON Halifax, NS
Matter Architectural
Studio Inc. Architects: WHW
Architects Inc.
Roof: TRADITION
*Head Office
(no manufacturing facility)