D05 High Flow Parallel Manifolds
D05 High Flow Parallel Manifolds
D05 High Flow Parallel Manifolds
T
T
3.22 2.72
[81.7] [69.2]
4.13 T T
5.00 [104.8]
[127.0] P P
P
P
B A GA B A
0.44
[11.1] 1.56 3.25 [82.6] TYP Flow Curve
25
[39.7] 5.00 [127.0] TYP
B B B P
05H
Velocity (fps)
-D
15 s age 5HP
1.38 All mounting hardware a s - 0
D
0.44 4.13 3.13 GA P p assage
[34.9] A A A is supplied. See page T p
[11.1] [104.8] [79.4] 1.50 5
1.38 [38.1] 64 for itemized list.
[34.9] 3.19 15 30 45
5.00 Flow (gpm)
0.44 0.56 [81.0]
[127.0] 0.88 Rated flow Pressure 25 gpm @ 15 fps
[11.1] [14.3] [22.2] Rated flow Tank 41 gpm @ 15 fps
No. of stations * 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
“A” length (code 3 spa.) 3.25 6.50 9.75 13.00 16.25 19.50 22.75 26.00 29.25 32.50 35.75 39.00 42.25 45.50 48.75 52.00 55.25 58.50 61.75 65.00 68.25
inch [mm] [82.6] [165.1] [247.7] [330.2] [412.8] [495.3] [577.9] [660.4] [743.0] [825.5] [908.1] [990.6] [1073.2] [1155.7] [1238.3] [1320.8] [1403.4] [1485.9] [1568.5] [1651.0] [1733.6]
apx. weight alum 7 12 17 22 27 33 38 43 48 53 58 63 68 74 79 84 89 94 99 104 110
lb [kg] [3] [5] [8] [10] [12] [15] [17] [20] [22] [24] [26] [29] [31] [34] [36] [38] [40] [43] [45] [47] [50]
apx. weight ferrous 19 38 57 75 85 113 132 151 170 189 208 226 245 264 283 302 320 339 358 377 396
lb [kg] [9] [17] [26] [34] [39] [51] [60] [69] [77] [86] [94] [103] [111] [120] [128] [137] [145] [154] [162] [171] [180]
“A” length (code 5 spa.) 8.25 13.25 18.25 23.25 28.25 33.25 38.25 43.25 48.25 53.25 58.25 63.25 68.25
inch [mm] -- [209.6] [336.6] [463.6] [590.6] [717.6] [844.6] [971.6] [1098.6] [1225.6] [1352.6] [1479.6] [1606.6] [1733.6] Port code Valve mtg. Manifold mtg.
apx. weight alum 18 26 33 41 48 56 63 71 79 87 95 103 111 0.25-20 UNC x 0.38-16 UNC x
lb [kg] -- [8] [12] [15] [19] [22] [25] [29] [32] [36] [39] [43] [47] [50] P, S 0.75 [19] DP 0.75 [19] DP
apx. weight ferrous 48 77 106 135 164 188 222 251 280 309 338 367 396 M6 ISO 6H x M10 ISO 6H x
lb [kg] -- [22] [35] [48] [61] [74] [85] [101] [114] [127] [140] [153] [166] [180] B, M, T 0.75 [19] DP 0.75 [19] DP
* Length of 01 station with relief cavity is 4.50 [114.3]. Gauge port not available on 01 station. Specifications, descriptions, and dimensional data are subject to
correction or change without notice or incurring obligation.
Download latest catalog page revisions at www.daman.com.
Material Valve
Pattern
Circuit No. of
Stations
Valve
Spacing
Port
Threads
/ Options
28
Daman Products Company, Inc. • 1811 North Home Street • Mishawaka, IN 46545-7267
Tel: 800.959.7841 574.259.7841 • Fax: 800.241.7664 • Email: sales@daman.com • www.daman.com
Products
Custom
Options - D05 High Flow Parallel Manifold
Manifolds
Standard
Pilot port location dimensions vary on (1) station manifolds
and manifolds with isolations. Contact Daman for cavity
ISOLATIONS
Parallel Circuit with X & Y Daman isolation options allow a manifold
locations if critical.
to have two independent pressure and/or
Pilot port: Valve cavity location when tank ports. Isolations are drilled rather
X on option 2 and 24, cavity, or cavity-isolation
Y on option 3 and 13, 1.00 than plugged to ensure a leakproof and
combination L or D is specified.
L on option 5. [25.4] failproof isolation.
Ordering * Isolation is Available #
3.25 code letter: between stations: of stations:
[82.6] T T
Plates
Cover
Valve cavity location P P
3.25 [82.6] spacing
X for cavity-isolation A 01 & 02 02-10
combination R or D.
4.00 B 02 & 03 03-11
"A" (See chart previous page)
[101.6] Y X B A GA B A C 03 & 04 04-12
D 04 & 05 05-13
T
T
Adaptors
P
J 09 & 10 10-18
P
Valve
0.75 5.00 [127.0] spacing
Pilot port: [19.1]
X on option 1 and 13, A 01 & 02 02-07
B B B B
Y on option 4 and 24. T T B 02 & 03 03-08
Y
GA C 03 & 04 04-09
A A A A D 04 & 05 05-10
2.00 P P
[50.8] E 05 & 06 06-11
L B A GA B A F 06 & 07 07-12
* Stations are numbered left to right.
Subplates
Parallel Circuit with Cavity Parallel Circuit with Isolations Cavity & Isolation Combinations
NOTES:
1) The GA port is not available
on a (1) station manifold.
2) The GA port is not available
T T T T T T when a pressure isolation is
located between stations 1 & 2.
P P P P P P
B A GA B A B A B A B A B A B A B A B A 3) Some cavity and isolation
Servo Valve
combinations are not possible.
Subplates
Valves with P in the nose and T out the Manifold shown with P isolation between 1 Option code L Option code R Consult factory to determine
side must be used. & 2 (PA), and T isolation between 2 & 3 (TB). Cavity left of isolation Cavity right of isolation availablity.
Option code D includes both cavities
Ordering Information
... /
Cavity &
Pressure
Tapping
Pilot Ports Cavity Tank Isolation Isolation
Plates
Isolation Combinations
DIN Cartridge
Valve Bodies
Omit if pilot ports not required Omit if cavity not required Omit if T isolation not required Combinations
Pilot ports available from 01-11 stations (3.25
4
Y port ISO 4401-05-05 Pressure Isolation D
Two relief cavities, one
NFPA T3.5.1-D05 Alt-A each side of isolation.
Omit if P isolation not required
X & Y ports ISO 4401-05-05
24 NFPA T3.5.1-D05 Alt-A Available with
PA...PJ spacing code 3
L ports
5 Available with
Proportional valves
PA...PF spacing code 5
Information
29
Technical
Daman Products Company, Inc. • 1811 North Home Street • Mishawaka, IN 46545-7267
Tel: 800.959.7841 574.259.7841 • Fax: 800.241.7664 • Email: sales@daman.com • www.daman.com