THE LEADER IN SWITCHGEAR
& SYSTEM SOLUTIONS

L&T is India's largest switchgear manufacturer, Typically, L&T engineers conduct a detailed study of the
customer's system, and provide a professional analysis of the
Inventor to convert design conceptualization to manufacturing
drawings. Every design is vetted using ANSYS software for its
application along with recommended cost-benefit solutions. shock and vibration withstand capability.
offering wide product ranges for virtually every application. The spectrum:
• Innovative and Totally Re-engineered solutions Quality assurance – Facilities have secured ISO 9001-2008
• Retrofit solutions certification and are NABL accredited.
Leveraging its technological resources, L&T is committed to offer • System up-gradation
L&T had entered into a long term partnership with M/s
indigenously engineered system solutions to customers. L&T's switchgear spectrum stretches from Push Buttons to Air Servowatch, UK for execution of IPMS projects. M/s
Circuit Breakers. L&T's leadership goes far beyond the range to Servowatch has a rich experience of over 35 years in IPMS and
include a number of factors like: equivalent projects. They have proven track records in many
• Volume – L&T manufactures over 36,000 ACBs and 32,000 navies including U.K., Australia, New Zealand, Thailand, U.S.A.,
switchboard panels every year. Portugal etc. Together, L&T and Servowatch have ushered in
• Sophistication of indigenous manufacturing facilities. cutting-edge technology in the Indian Navy with Servowatch
providing the state-of-the-art technology and L&T spearheading
Investment in R&D – facilities include 85kA test station that is Indigenisation and Life Cycle Support in line with the country's
NABL accredited and certified by KEMA. A camera taking drive in attaining Self Reliance in Critical Defense Projects.
33000 frames per second to study dynamic behavior. Subsequently, L&T has acquired Servowatch & is a subsidiary
Concurrent engineering with a sophisticated set-up uses Pro-E/ company of L&T.

The expansive range of switchgear offered by L&T. ACB Assembly Shop where over 36000 ACBs are manufactured per year.

1 2
THE LEADER IN SWITCHGEAR
& SYSTEM SOLUTIONS

L&T is India's largest switchgear manufacturer, Typically, L&T engineers conduct a detailed study of the
customer's system, and provide a professional analysis of the
Inventor to convert design conceptualization to manufacturing
drawings. Every design is vetted using ANSYS software for its
application along with recommended cost-benefit solutions. shock and vibration withstand capability.
offering wide product ranges for virtually every application. The spectrum:
• Innovative and Totally Re-engineered solutions Quality assurance – Facilities have secured ISO 9001-2008
• Retrofit solutions certification and are NABL accredited.
Leveraging its technological resources, L&T is committed to offer • System up-gradation
L&T had entered into a long term partnership with M/s
indigenously engineered system solutions to customers. L&T's switchgear spectrum stretches from Push Buttons to Air Servowatch, UK for execution of IPMS projects. M/s
Circuit Breakers. L&T's leadership goes far beyond the range to Servowatch has a rich experience of over 35 years in IPMS and
include a number of factors like: equivalent projects. They have proven track records in many
• Volume – L&T manufactures over 36,000 ACBs and 32,000 navies including U.K., Australia, New Zealand, Thailand, U.S.A.,
switchboard panels every year. Portugal etc. Together, L&T and Servowatch have ushered in
• Sophistication of indigenous manufacturing facilities. cutting-edge technology in the Indian Navy with Servowatch
providing the state-of-the-art technology and L&T spearheading
Investment in R&D – facilities include 85kA test station that is Indigenisation and Life Cycle Support in line with the country's
NABL accredited and certified by KEMA. A camera taking drive in attaining Self Reliance in Critical Defense Projects.
33000 frames per second to study dynamic behavior. Subsequently, L&T has acquired Servowatch & is a subsidiary
Concurrent engineering with a sophisticated set-up uses Pro-E/ company of L&T.

The expansive range of switchgear offered by L&T. ACB Assembly Shop where over 36000 ACBs are manufactured per year.

1 2
PRODUCT
RANGE
Machinery Control Systems (Motors & Starters) Features of Custom-built Switchboards

• Composite offering of Starters along with Naval • Rated up to 6000A


Duty Motors • 690V / 440V / 380V / 230V Voltage Levels
• Direct-On-Line Starter • Fault withstand capacity up to 100kA
• Star-Delta Starter • Compatible with intelligent systems
• Soft Starter (AC & DC application) • Designed to offer highest operational safety and
• Designed as per EED-Q-071 & IEC 60947 reliability
• Microprocessor based Motor Protection Unit • Customized dimensions and arrangement to suit
• IPMS-compliant customers requirements
• Relay based/PLC based controls available • Integrated with APMS
• Ready for IPMS integration
Custom-built Switchboards • Available in Aluminum, Stainless steel, & Mild steel
enclosures
Switchboards are designed and manufactured up to
Type approved Marinised Switchgear
690V, 6000A, 100KA

Air Circuit Breakers (ACB) • Germanischer Lloyds (GL)


• RINA
A product list indicative of L&T's comprehensive range
• Nippon Kaiji Kyokai (NK)
of products and systems certified for naval application
(JSS55555).
Moulded Case Circuit Breakers (MCCB)
• 630-9000A range
• Three & four pole version • 16-1250A range
• Fixed and draw-out version • Three & four pole versions
• Manual or electrically operated version • Separate ranges for different breaking capacities
• Breaking capacity up to 100kA • Fixed, plug-in and with-drawable versions
• Supported with range of protection releases • Manual, rotary and electrical operation
• Replaceable arcing contacts, safety shutters for • Low let-through energy
extended life & safety • Low watt loss
• Complying with IEC 60947-2, EN 60947 -2 • Compact design
• AC & DC application • Common & easy to fit accessories
• Use of environmental friendly material
Protection Relays • Comply with IEC 60947-2, EN 60947-2
• AC & DC application
• Generator protection Energy Distribution Center Range of standardized starters - DOL, Star Delta, Soft Starter
• Auto-synchronization
• Load sharing / shedding
• Motor protection Relays (IPMS Compatible)

Changeover Systems
• Manual
• Automatic with fast changeover switches (<15 msec
Changeover time)

L&T Switchgear is Certified by:


• Director General of Quality Assurance (DGQA)
Indian Navy
• American Bureau of Shipping (ABS)
• Indian Register of Shipping (IRS)
• Det Norske Veritas (DNV)
• Lloyd's Register of Shipping (LRS)
• Bureau Veritas (BV) Type approval Certification

Main Switchboard with APMS functionality

3 4
PRODUCT
RANGE
Machinery Control Systems (Motors & Starters) Features of Custom-built Switchboards

• Composite offering of Starters along with Naval • Rated up to 6000A


Duty Motors • 690V / 440V / 380V / 230V Voltage Levels
• Direct-On-Line Starter • Fault withstand capacity up to 100kA
• Star-Delta Starter • Compatible with intelligent systems
• Soft Starter (AC & DC application) • Designed to offer highest operational safety and
• Designed as per EED-Q-071 & IEC 60947 reliability
• Microprocessor based Motor Protection Unit • Customized dimensions and arrangement to suit
• IPMS-compliant customers requirements
• Relay based/PLC based controls available • Integrated with APMS
• Ready for IPMS integration
Custom-built Switchboards • Available in Aluminum, Stainless steel, & Mild steel
enclosures
Switchboards are designed and manufactured up to
Type approved Marinised Switchgear
690V, 6000A, 100KA

Air Circuit Breakers (ACB) • Germanischer Lloyds (GL)


• RINA
A product list indicative of L&T's comprehensive range
• Nippon Kaiji Kyokai (NK)
of products and systems certified for naval application
(JSS55555).
Moulded Case Circuit Breakers (MCCB)
• 630-9000A range
• Three & four pole version • 16-1250A range
• Fixed and draw-out version • Three & four pole versions
• Manual or electrically operated version • Separate ranges for different breaking capacities
• Breaking capacity up to 100kA • Fixed, plug-in and with-drawable versions
• Supported with range of protection releases • Manual, rotary and electrical operation
• Replaceable arcing contacts, safety shutters for • Low let-through energy
extended life & safety • Low watt loss
• Complying with IEC 60947-2, EN 60947 -2 • Compact design
• AC & DC application • Common & easy to fit accessories
• Use of environmental friendly material
Protection Relays • Comply with IEC 60947-2, EN 60947-2
• AC & DC application
• Generator protection Energy Distribution Center Range of standardized starters - DOL, Star Delta, Soft Starter
• Auto-synchronization
• Load sharing / shedding
• Motor protection Relays (IPMS Compatible)

Changeover Systems
• Manual
• Automatic with fast changeover switches (<15 msec
Changeover time)

L&T Switchgear is Certified by:


• Director General of Quality Assurance (DGQA)
Indian Navy
• American Bureau of Shipping (ABS)
• Indian Register of Shipping (IRS)
• Det Norske Veritas (DNV)
• Lloyd's Register of Shipping (LRS)
• Bureau Veritas (BV) Type approval Certification

Main Switchboard with APMS functionality

3 4
Retrofitted Main Switchboard with APMS Console Integrated Bridge System

Switchboard for shore support facility MCR Console with Platform Management System Machinery Control System Machinery Control Console

MV Switchboards • Dual Redundant Network Alarm Monitoring System (AMS) The status of following parameters will be monitored
• Navigation and communication equipment for by alarm & monitoring system:
• Type approved MV Panel up to 36 kV system voltage centralized monitoring and control The Alarm system provides the following facilities:
• Temperature sensors (PT 100, thermocouple)
• Complete range from 630A to 4000A • Interface with IPMS, Machinery Data • User Configurable Alarm Parameters
• Pressure transmitters (4 ~ 20 mA)
• Short time rating up to 40 kA for 3sec • Alarm Status (Active / Reset, Acknowledged)
• Pressure switches
• Metal clad, fully compartmentalized panel Integrated Platform Machinery Control System • Alarm Message (Text description, time & date)
• Speed sensors
• Internal arc compliant as per IEC 62271-200 (IPMCS) • Online alarm printing
• Temperature switches
• In-built comprehensive safety interlocks • Database for Alarm list & Event List
Control and Monitoring of: • Level switches (Float type)
• Integrated with hybrid as well as eectric propulsion • Engineers Call system
• Main Propulsion Machinery and associated systems • Level transmitters
system • Alarm Acknowledgment by individual alarm or
• Auxiliary Propulsion Machinery and associated systems
alarm page
• Auxiliary machinery and systems
Automated Power Management System (APMS) • Power Management System • Online event printing
• Battle Damage Control System • Comprehensive Alarm
• Automatic Generator synchronizing & load sharing
• Bilge & tank levels • Event browsing facilities
• Load Shedding
• Fire Alarm and Flood Level Indications • Alarm Blocking
• Islanding
• Vibration Monitoring • Tagging for selected signals
• Generator Protection
• Event Logging Features The Alarm Monitoring System architecture is laid out in
• Fault/Alarm History • Integrated Onboard Training Simulator 3 levels of architecture:
• Trending • Online Health Monitoring • Data acquisition level
• Blackout Recovery • Performance Prediction • Network level
• Dynamic Analysis & Engine Performance • HMI
Integrated Bridge System (IBS) • Mimics providing sensor information and control
function for machinery and other equipment.
• Centralized Control of Navigation Equipment: • Common Dual Redundant Gigabit Network for all
Radar functions viz. IPMS, IBS and APMS.
ECDIS • Standard RTU configuration for all function viz. IPMS,
• Integrated GMDSS and Communication Equipment IBS and APMS
• Redundancy of workstation
• Expandability
Standalone IBS Console

5 6
Retrofitted Main Switchboard with APMS Console Integrated Bridge System

Switchboard for shore support facility MCR Console with Platform Management System Machinery Control System Machinery Control Console

MV Switchboards • Dual Redundant Network Alarm Monitoring System (AMS) The status of following parameters will be monitored
• Navigation and communication equipment for by alarm & monitoring system:
• Type approved MV Panel up to 36 kV system voltage centralized monitoring and control The Alarm system provides the following facilities:
• Temperature sensors (PT 100, thermocouple)
• Complete range from 630A to 4000A • Interface with IPMS, Machinery Data • User Configurable Alarm Parameters
• Pressure transmitters (4 ~ 20 mA)
• Short time rating up to 40 kA for 3sec • Alarm Status (Active / Reset, Acknowledged)
• Pressure switches
• Metal clad, fully compartmentalized panel Integrated Platform Machinery Control System • Alarm Message (Text description, time & date)
• Speed sensors
• Internal arc compliant as per IEC 62271-200 (IPMCS) • Online alarm printing
• Temperature switches
• In-built comprehensive safety interlocks • Database for Alarm list & Event List
Control and Monitoring of: • Level switches (Float type)
• Integrated with hybrid as well as eectric propulsion • Engineers Call system
• Main Propulsion Machinery and associated systems • Level transmitters
system • Alarm Acknowledgment by individual alarm or
• Auxiliary Propulsion Machinery and associated systems
alarm page
• Auxiliary machinery and systems
Automated Power Management System (APMS) • Power Management System • Online event printing
• Battle Damage Control System • Comprehensive Alarm
• Automatic Generator synchronizing & load sharing
• Bilge & tank levels • Event browsing facilities
• Load Shedding
• Fire Alarm and Flood Level Indications • Alarm Blocking
• Islanding
• Vibration Monitoring • Tagging for selected signals
• Generator Protection
• Event Logging Features The Alarm Monitoring System architecture is laid out in
• Fault/Alarm History • Integrated Onboard Training Simulator 3 levels of architecture:
• Trending • Online Health Monitoring • Data acquisition level
• Blackout Recovery • Performance Prediction • Network level
• Dynamic Analysis & Engine Performance • HMI
Integrated Bridge System (IBS) • Mimics providing sensor information and control
function for machinery and other equipment.
• Centralized Control of Navigation Equipment: • Common Dual Redundant Gigabit Network for all
Radar functions viz. IPMS, IBS and APMS.
ECDIS • Standard RTU configuration for all function viz. IPMS,
• Integrated GMDSS and Communication Equipment IBS and APMS
• Redundancy of workstation
• Expandability
Standalone IBS Console

5 6
• Minesweepers precise measurement of small fields in arbitrary
• Destroyers magnetic environment.
• Offshore Patrol Vessels
• Submarines The objectives of the land range are:
• Retrofitment projects • Reduction of the magnetic signature of components
• Measurement and analysis of magnetic stray fields of
Our offerings: military covering the range from DC to over 3 kHz.
• Degaussing coil design and layout • Formulation and analysis of new magnetic treatment
• Completely indigenized yet fully type tested and compensation methods
hardware including • Analysis of magnetic stability
- Command and Control Unit • Fundamental research for generating small magnetic
- Power amplifier signatures
- Degaussing Coils
• Degaussing software - custom built as per the A complete Degaussing Range comprises:
magnetic signature of the vessel
• Magnetic Multi Channel Measurement System
• Master Control Unit
Salient features
• Software
• A promised Degaussing ON/OFF Ratio 1:10 for all the
• Magnetic Field Simulator
solutions over time
• Magnetic Degaussing Unit
• Modular distributed architecture resulting in
• Nonmagnetic Building
reduction in MTTR
• Nonmagnetic Trolley System
• Easy and fast installation, maintenance and repair of
• Nonmagnetic Rail Guiding System
the system
• Crane System
• Cost effective
• High reliability
DEPERMING RANGE
• Geo Mag maps based control
• Provision of Magnetometer Sensing Modes A Deperming Facility removes the permanent
(Auto & Manual) signatures or generation of well defined permanent
• Communication through Ethernet or RS 485 signatures of naval vessels after ascertaining the
• Configurable regarding expected Degaussing Ratio magnetic signature levels.
• Warnings and alarms management
The facility can also be used to calibrate onboard
LAND DEPERMING RANGE Degaussing systems to ensure minimal signatures.
A Land Magnetic Deperming Range is a facility for
magnetic treatment of machine parts to minimize their
Typical architecture for IPMS / AMS
magnetic signature caused by magnetic stray fields.
This requires both, generating high magnetic fields and

Vessel Management System (VMS) Alarm annunciation and displays will be in the
following formats:
The Vessel Management System (VMS) has a provision
• LED Annunciator display at each DACU
for continuous monitoring and time-based records of
• 2 line LCD Operator Interface Unit at each DACU
various parameters like temperature pressure level, etc
• Tracker ball controlled PC monitors
for ship systems like Main Engine and Diesel
• Engineers Alarm System
Generators, Bilge System, Advanced Fire Detection
• Dead Man Alarm System
Systems (AFDS), Pressure Air System, Thruster System
and so on. The System has DACU (Data Acquisition
Degaussing -
Control Unit), rugged PC workstation (for monitoring
The magnetic signature control system
and controlling), and communication network. The
system monitors various parameters like Temperature, Sea mines and torpedoes detect a vessel's magnetic
Pressure, Speed, etc. and generates Audio Visual alarms signature and attack the particular type of vessel based
Software Representation of the actual Ship to Derive Coil Design Data
in case of their abnormality; it also helps to take on its specific magnetic signature.
appropriate action for safe navigation of ship. VMS also
controls various motors and pumps. To save a vessel from these attacks, a counter-magnetic
field has to be generated onboard vessel. This system
Key Advantages:
which generates required counter-magnetic field in
• Modular System Approach
three axes is a Degaussing System.
• Dual Redundancy For Key Functions
• Fully Type Approved Equipment
L&T has successfully indigenized the degaussing system
• Tested, Certified System dispatch
to suit naval vessels operating at various locations
• Redundant Array of Independent Disk (RAID) in the
throughout the globe. The indigenized solution reduces
Machinery Control Room offering comprehensive
the cost of the system substantially and also reduces
monitoring and control of the ships services.
MTTR for such an important system. Our Degaussing
• Expansion flexibility, allowing continual network
system can be custom built for:
upgrade and development.
• Frigates
• Life Cycle Support.
• Air Defence Ships
• Corvettes Degaussing Power Amplifier Cubicle with Control & Command Unit Deperming Calculations for Submarine

7 8
• Minesweepers precise measurement of small fields in arbitrary
• Destroyers magnetic environment.
• Offshore Patrol Vessels
• Submarines The objectives of the land range are:
• Retrofitment projects • Reduction of the magnetic signature of components
• Measurement and analysis of magnetic stray fields of
Our offerings: military covering the range from DC to over 3 kHz.
• Degaussing coil design and layout • Formulation and analysis of new magnetic treatment
• Completely indigenized yet fully type tested and compensation methods
hardware including • Analysis of magnetic stability
- Command and Control Unit • Fundamental research for generating small magnetic
- Power amplifier signatures
- Degaussing Coils
• Degaussing software - custom built as per the A complete Degaussing Range comprises:
magnetic signature of the vessel
• Magnetic Multi Channel Measurement System
• Master Control Unit
Salient features
• Software
• A promised Degaussing ON/OFF Ratio 1:10 for all the
• Magnetic Field Simulator
solutions over time
• Magnetic Degaussing Unit
• Modular distributed architecture resulting in
• Nonmagnetic Building
reduction in MTTR
• Nonmagnetic Trolley System
• Easy and fast installation, maintenance and repair of
• Nonmagnetic Rail Guiding System
the system
• Crane System
• Cost effective
• High reliability
DEPERMING RANGE
• Geo Mag maps based control
• Provision of Magnetometer Sensing Modes A Deperming Facility removes the permanent
(Auto & Manual) signatures or generation of well defined permanent
• Communication through Ethernet or RS 485 signatures of naval vessels after ascertaining the
• Configurable regarding expected Degaussing Ratio magnetic signature levels.
• Warnings and alarms management
The facility can also be used to calibrate onboard
LAND DEPERMING RANGE Degaussing systems to ensure minimal signatures.
A Land Magnetic Deperming Range is a facility for
magnetic treatment of machine parts to minimize their
Typical architecture for IPMS / AMS
magnetic signature caused by magnetic stray fields.
This requires both, generating high magnetic fields and

Vessel Management System (VMS) Alarm annunciation and displays will be in the
following formats:
The Vessel Management System (VMS) has a provision
• LED Annunciator display at each DACU
for continuous monitoring and time-based records of
• 2 line LCD Operator Interface Unit at each DACU
various parameters like temperature pressure level, etc
• Tracker ball controlled PC monitors
for ship systems like Main Engine and Diesel
• Engineers Alarm System
Generators, Bilge System, Advanced Fire Detection
• Dead Man Alarm System
Systems (AFDS), Pressure Air System, Thruster System
and so on. The System has DACU (Data Acquisition
Degaussing -
Control Unit), rugged PC workstation (for monitoring
The magnetic signature control system
and controlling), and communication network. The
system monitors various parameters like Temperature, Sea mines and torpedoes detect a vessel's magnetic
Pressure, Speed, etc. and generates Audio Visual alarms signature and attack the particular type of vessel based
Software Representation of the actual Ship to Derive Coil Design Data
in case of their abnormality; it also helps to take on its specific magnetic signature.
appropriate action for safe navigation of ship. VMS also
controls various motors and pumps. To save a vessel from these attacks, a counter-magnetic
field has to be generated onboard vessel. This system
Key Advantages:
which generates required counter-magnetic field in
• Modular System Approach
three axes is a Degaussing System.
• Dual Redundancy For Key Functions
• Fully Type Approved Equipment
L&T has successfully indigenized the degaussing system
• Tested, Certified System dispatch
to suit naval vessels operating at various locations
• Redundant Array of Independent Disk (RAID) in the
throughout the globe. The indigenized solution reduces
Machinery Control Room offering comprehensive
the cost of the system substantially and also reduces
monitoring and control of the ships services.
MTTR for such an important system. Our Degaussing
• Expansion flexibility, allowing continual network
system can be custom built for:
upgrade and development.
• Frigates
• Life Cycle Support.
• Air Defence Ships
• Corvettes Degaussing Power Amplifier Cubicle with Control & Command Unit Deperming Calculations for Submarine

7 8
3D Layout for Cable Tray Arrangement Compartment Layouts 3D Modelling of Switchboard 3D Modelling of Console

Preparation and Submission of Load Analysis Antennae and Mast Layouts ANSYS (Shock & Vibration) Analysis Onboard Installation of electrical components including cabling and lighting

Turnkey solutions §Wiring drawings for the Integrated Platform §Engine Order Telegraphs, UPS, Flood Alarm System, §Galley & Laundry Equipment
Management System / Alarm Monitoring System Fire Detection System, Tank Gauging System, Soft §Office & SRE Equipment
• Finalization of DG set capacity and load distribution
§As fitted drawings for all electrical sub-systems control for Main Engines and other auxiliary §WT & Decorative Light fittings, switch-sockets.
after approval of load analysis and single line
• Design of wiring drawings for yard-supplied machineries i.e. bilge pumps, ventilation fans, • Supply & Installation of Electrical Equipment
drawing by classification society / owners
equipment salvage pumps, FM 200 including hot-work
• Design & Supply of Class / Navy approved Main
§Main Engines, Main DG sets, Emergency DG Set, §Equipment Health Monitoring System & Dynamic §Cable Trays, Cable Hangers, Multi Cable Transits
Switchboards, Group Starter Panels, Distribution
STP, AC Plant, Pumps & other machineries Analysis (MCTs)
boards, Transformers, TRUs, DCDBs, NLCP etc.
§External Communication Equipment – VHF/UHF §Naval Ships - Battle Damage Control System, §Equipment Foundation for Switchboards, Electrical
• Design of shipboard electrical
sets, VLF sets, HF sets, etc. Degaussing System equipment, Antennae, Lighting fixtures, IPMS
§Short Circuit Calculation, Protection Co-ordination
§Manufacturing, Installation and Trials of • Design, Supply & Installation of Integrated Bridge equipment, etc.
§ANSYS Analysis
Electrical & Automation Systems System §External Communication Equipment
§Cable tray layouts and cable schedules
• Design, Supply & Installation of Integrated Propulsion §Bridge Management System including RADAR, §Hydrographic Equipment
§Equipment Location layouts, Lighting calculations
and Machinery Control System (IPMCS) and Auto Conning and ECDIS operation • Additional Services
and lighting layouts
Power Management System (APMS) / Alarm §Navigation & Communication Equipment i.e. §Installation of Hydrographic / External
§Compartment layouts for Galley, Chart Room,
Monitoring System (AMS) RADAR, Gyro Compass, Magnetic Compass, AIS, Communication Equipment
Bridge, MCR, Gyro cum ECP room, WT Office,
§Remote Terminal Units (RTUs) with VME / PLC Navtax, Weather Chart Facsimile, INMARSAT C, §Completion of Alignment Survey for installation of
Antennae Layout as per IMO guidelines
technology INMARSAT M, etc. Hydrographic equipment
§Finalization of navigation & communication
§Drop-in plate for engine control with VME / PLC §Intercom System, Auto Telephone System, Talk §Setting of voltage and frequency droops for DG
equipment in accordance with SOLAS requirements
based control Back System sets & Manual Paralleling of DG sets
§COLREG-compliant LSS plan
§MCR Console, Bridge Console and APMS • Supply & Installation of electrical equipment
§FMEA analysis for switchboards / control system
standalone consoles including COTS items

9 10
3D Layout for Cable Tray Arrangement Compartment Layouts 3D Modelling of Switchboard 3D Modelling of Console

Preparation and Submission of Load Analysis Antennae and Mast Layouts ANSYS (Shock & Vibration) Analysis Onboard Installation of electrical components including cabling and lighting

Turnkey solutions §Wiring drawings for the Integrated Platform §Engine Order Telegraphs, UPS, Flood Alarm System, §Galley & Laundry Equipment
Management System / Alarm Monitoring System Fire Detection System, Tank Gauging System, Soft §Office & SRE Equipment
• Finalization of DG set capacity and load distribution
§As fitted drawings for all electrical sub-systems control for Main Engines and other auxiliary §WT & Decorative Light fittings, switch-sockets.
after approval of load analysis and single line
• Design of wiring drawings for yard-supplied machineries i.e. bilge pumps, ventilation fans, • Supply & Installation of Electrical Equipment
drawing by classification society / owners
equipment salvage pumps, FM 200 including hot-work
• Design & Supply of Class / Navy approved Main
§Main Engines, Main DG sets, Emergency DG Set, §Equipment Health Monitoring System & Dynamic §Cable Trays, Cable Hangers, Multi Cable Transits
Switchboards, Group Starter Panels, Distribution
STP, AC Plant, Pumps & other machineries Analysis (MCTs)
boards, Transformers, TRUs, DCDBs, NLCP etc.
§External Communication Equipment – VHF/UHF §Naval Ships - Battle Damage Control System, §Equipment Foundation for Switchboards, Electrical
• Design of shipboard electrical
sets, VLF sets, HF sets, etc. Degaussing System equipment, Antennae, Lighting fixtures, IPMS
§Short Circuit Calculation, Protection Co-ordination
§Manufacturing, Installation and Trials of • Design, Supply & Installation of Integrated Bridge equipment, etc.
§ANSYS Analysis
Electrical & Automation Systems System §External Communication Equipment
§Cable tray layouts and cable schedules
• Design, Supply & Installation of Integrated Propulsion §Bridge Management System including RADAR, §Hydrographic Equipment
§Equipment Location layouts, Lighting calculations
and Machinery Control System (IPMCS) and Auto Conning and ECDIS operation • Additional Services
and lighting layouts
Power Management System (APMS) / Alarm §Navigation & Communication Equipment i.e. §Installation of Hydrographic / External
§Compartment layouts for Galley, Chart Room,
Monitoring System (AMS) RADAR, Gyro Compass, Magnetic Compass, AIS, Communication Equipment
Bridge, MCR, Gyro cum ECP room, WT Office,
§Remote Terminal Units (RTUs) with VME / PLC Navtax, Weather Chart Facsimile, INMARSAT C, §Completion of Alignment Survey for installation of
Antennae Layout as per IMO guidelines
technology INMARSAT M, etc. Hydrographic equipment
§Finalization of navigation & communication
§Drop-in plate for engine control with VME / PLC §Intercom System, Auto Telephone System, Talk §Setting of voltage and frequency droops for DG
equipment in accordance with SOLAS requirements
based control Back System sets & Manual Paralleling of DG sets
§COLREG-compliant LSS plan
§MCR Console, Bridge Console and APMS • Supply & Installation of electrical equipment
§FMEA analysis for switchboards / control system
standalone consoles including COTS items

9 10
Major Orders Major orders
Naval Switchboards & Control Systems Naval Switchboards & Control Systems

Yard/ No. of Year of Yard/ No. of Year of


Customer Type of Vessel/Owner Scope of supply in brief Customer Type of Vessel/Owner Scope of supply in brief
Hull No. Vessels Supply Hull No. Vessels Supply

o Main switchboards with Indian Navy RE Class of ship of o Main Switchboards - 1 2008
Automated Power Management System 1194 Indian Navy o Local Control Panel
Naval Offshore Patrol o Emergency Switchboard 1195 4 2008 - Indian Navy Minesweepers of o Main Switchboards - 6 2005-
Vessel for Indian Navy o Energy Distribution Centers 1196 2010 Indian Navy 2008
Goa Shipyard Ltd. o 440V Power Panels 1211 Shalimar Works 500T Fuel Barge for o Main Switchboard 766 2 2009
o Integrated Platform Management System Indian Navy 767
Offshore Patrol Vessel o Emergency Switchboard 1203 3 2009 Cochin Shipyard Indian Air Craft Carrier o Main Switchboard S-071 1 2012
for Indian Coast Guard 1204 Limited (P71) for Indian Navy o Feeder section
1205 o Energy Distribution Centers
ASW Corvettes for o Degaussing System 3017- 4 2009 o Power Distribution Boards
Garden Reach Indian Navy o Converted Supply Switchboard 3020 2008 Hindustan Shipyard 50T Bollard Pull Tug for o Alarm Monitoring System 11160 to 5 2011 to
Shipbuilders & Water Jet fast o Main Switchboard 2057- 10 2008 Limited Indian Coast Guard 11164 2013
Engineers Ltd. Attack Craft 2066 o Main Switchboard
Indian Coast Guard o Main Switchboard 2072- 8 2010 o Distribution Boards
Inshore Patrol Vessel 2079 Bharti Shipyard 200T Water Barge o Group Starter panels 431 to 3 2013
Mauritius o Main Switchboard for Indian Navy o Battery chargers 433
Offshore Patrol Vessel o Emergency Switchboard 3021 1 2012 & o Starters
o Addressable Fire Detection System 2013 o Main Switchboard
Complete Electrification including supply of all o Distribution Boards 35001 Delivered
electricals like : o Group Starter panels to for first
o Main Switchboard o Battery chargers 350036 54 twenty six
Alcock Ashdown Naval Survey Vessel o Emergency Switchboard L&T Shipbuilding Interceptor Boats o Addressable Fire Detection System & 36001 ships since
(Gujarat) Limited for Indian Navy o Group Starter Panels 257- 6 Delivered for Indian Coast Guard o Flood detection system to 2011 to
o Galley & pantry Equipment 262 for first o Consoles 36018 2014
o Cables & accessories two ships o General Alarm System
o Integrated Platform Management System in 2009 o Tank Gauging system
o Auto Power Management System o Main Switchboard
o Integrated Bridge System o Distribution Boards
o Main Switchboards with Automated o Group Starter panels
Power Management System Temba 10T Tug for Indian Navy o Battery chargers 145 to 6 2011
o Feeder Sections o Galley equipments 150 to 2013
o Energy Distribution Centers o Consoles
o Local Control Panel o Communication equipment
Mazagon Dock Destroyers for o Shore connection box 12701 o Main Switchboard
Limited Indian Navy o Converted Supply Switchboard 12702 3 2006 - o Distribution Boards
o Helo-Starting rectifier 12703 2008 Hindustan Shipyard Fleet Support Vessel o Group Starter panels 11184 1 Supply
o Bridge Console Limited o Battery chargers still to
o Power panels o Integrated Platform commence
o Starter & Control panels Management System
Indian Navy Underwater o Switchboards - 2 2011 - o Addressable Fire Detection System - 4 2014
Platforms o Power Equipment 2012 Indian Navy SNF Class o Helo Starting Rectifier

11 12
Major Orders Major orders
Naval Switchboards & Control Systems Naval Switchboards & Control Systems

Yard/ No. of Year of Yard/ No. of Year of


Customer Type of Vessel/Owner Scope of supply in brief Customer Type of Vessel/Owner Scope of supply in brief
Hull No. Vessels Supply Hull No. Vessels Supply

o Main switchboards with Indian Navy RE Class of ship of o Main Switchboards - 1 2008
Automated Power Management System 1194 Indian Navy o Local Control Panel
Naval Offshore Patrol o Emergency Switchboard 1195 4 2008 - Indian Navy Minesweepers of o Main Switchboards - 6 2005-
Vessel for Indian Navy o Energy Distribution Centers 1196 2010 Indian Navy 2008
Goa Shipyard Ltd. o 440V Power Panels 1211 Shalimar Works 500T Fuel Barge for o Main Switchboard 766 2 2009
o Integrated Platform Management System Indian Navy 767
Offshore Patrol Vessel o Emergency Switchboard 1203 3 2009 Cochin Shipyard Indian Air Craft Carrier o Main Switchboard S-071 1 2012
for Indian Coast Guard 1204 Limited (P71) for Indian Navy o Feeder section
1205 o Energy Distribution Centers
ASW Corvettes for o Degaussing System 3017- 4 2009 o Power Distribution Boards
Garden Reach Indian Navy o Converted Supply Switchboard 3020 2008 Hindustan Shipyard 50T Bollard Pull Tug for o Alarm Monitoring System 11160 to 5 2011 to
Shipbuilders & Water Jet fast o Main Switchboard 2057- 10 2008 Limited Indian Coast Guard 11164 2013
Engineers Ltd. Attack Craft 2066 o Main Switchboard
Indian Coast Guard o Main Switchboard 2072- 8 2010 o Distribution Boards
Inshore Patrol Vessel 2079 Bharti Shipyard 200T Water Barge o Group Starter panels 431 to 3 2013
Mauritius o Main Switchboard for Indian Navy o Battery chargers 433
Offshore Patrol Vessel o Emergency Switchboard 3021 1 2012 & o Starters
o Addressable Fire Detection System 2013 o Main Switchboard
Complete Electrification including supply of all o Distribution Boards 35001 Delivered
electricals like : o Group Starter panels to for first
o Main Switchboard o Battery chargers 350036 54 twenty six
Alcock Ashdown Naval Survey Vessel o Emergency Switchboard L&T Shipbuilding Interceptor Boats o Addressable Fire Detection System & 36001 ships since
(Gujarat) Limited for Indian Navy o Group Starter Panels 257- 6 Delivered for Indian Coast Guard o Flood detection system to 2011 to
o Galley & pantry Equipment 262 for first o Consoles 36018 2014
o Cables & accessories two ships o General Alarm System
o Integrated Platform Management System in 2009 o Tank Gauging system
o Auto Power Management System o Main Switchboard
o Integrated Bridge System o Distribution Boards
o Main Switchboards with Automated o Group Starter panels
Power Management System Temba 10T Tug for Indian Navy o Battery chargers 145 to 6 2011
o Feeder Sections o Galley equipments 150 to 2013
o Energy Distribution Centers o Consoles
o Local Control Panel o Communication equipment
Mazagon Dock Destroyers for o Shore connection box 12701 o Main Switchboard
Limited Indian Navy o Converted Supply Switchboard 12702 3 2006 - o Distribution Boards
o Helo-Starting rectifier 12703 2008 Hindustan Shipyard Fleet Support Vessel o Group Starter panels 11184 1 Supply
o Bridge Console Limited o Battery chargers still to
o Power panels o Integrated Platform commence
o Starter & Control panels Management System
Indian Navy Underwater o Switchboards - 2 2011 - o Addressable Fire Detection System - 4 2014
Platforms o Power Equipment 2012 Indian Navy SNF Class o Helo Starting Rectifier

11 12
Major orders Major Orders
Naval Switchboards & Control Systems Commercial Switchboards & Control Systems

Yard/ No. of Year of Yard/ No. of Year of


Customer Type of Vessel/Owner Scope of supply in brief Customer Type of Vessel/Owner Scope of supply in brief
Hull No. Vessels Supply Hull No. Vessels Supply

o Main Switchboard o 690V Main Switchboard


o Distribution Boards o 440V Main Switchboards
o Group Starter panels Converteam UK Flexible Pipelay Vessel o 220V Main Switchboards 602 1 2009
Temba 25T Tug for Indian Navy o Battery chargers 151 4 2012 Ltd./EZRA Lewak Crusader (134m) o 440V & 220CV Emergency Switchboards

o Consoles to to 2013 Marine, Singapore o 440V, 220V AC & 24V DC DBs

o Galley equipment 154 o Distribution Transformers

o Communication equipment o Starters (DOL & Soft)

o Main Switchboard o Main Switchboard

o Group Starter Panels o Emergency Switchboard


ABG o Group Starter Panels
o Distribution Boards & Starters
Shipyard/Tanker 80T Anchor o Distribution Boards (AC & DC) 327 2 2009
Modest 500T Fuel Barge o Cables & accessories 316 to 7 2011 -
Pacific, Handling Tug o Navigation Lighting Panel 328
Infrastructure for Indian Navy o SRE system, Engineers call system, AFDS 322 2013
Singapore o Distribution Transformers
o Luminaries
o Alarm Monitoring System
o Alarm monitoring system
o Main Switchboard
o Main Switchboard
o Emergency Switchboard
o Power Management System
L&T RoRo LoLo Ships o Group Starter Panels 81001 3 2009
Indian Navy P25 o Distribution Boards - 4 2013
Shipyard/Rolldock, o Distribution Boards (AC & DC) 81002
o Changeover Switches
Netherlands o Navigation Lighting Panel 81003
o Transformers
o Shore Supply Box
o Degaussing System
Greatship Global Multirole & ROV o 690V Main Switchboard 314 - 4 2009
o Main Switchboard
Offshore Services Support Vessel o 1050kW Soft starters 344
Mazgaon Dock Destroyers (P15B) o Energy Distribution Centers 12704 4 Supply
Pte Ltd., Multi-Purpose Survey o 690V Main Switchboard 26775 2 2009
Limited for Indian Navy o DA Local Control Panel to still to Sinagapore Vessels o 1050kW Soft starters 26784
o Automated Power Management System 12707 commence o Main Switchboard
o Integrated Platform Management System o Emergency Switchboard
Turnkey Electrical Package including: L&T Shipyard/ Big Lift Cargo Vessel o Group Starter Panels 81007 1 2011
o Main & Emergency Switchboard Big Lift, o Distribution Boards (AC & DC)
ABG Shipyard Cadet Training Ship o Group Starter Panels 397, 3 Supply Netherlands o Navigation Lighting Panel
for Indian Navy o Distribution Boards 398 & still to o Distribution Transformers
o Helo Starting rectifiers 423 commence o TRUs
o Integrated Platform Management System o Alarm Monitoring System
o Integrated Bridge System ABG Shipyard/ 130T BP Anchor o Alarm Monitoring System 343, 344 4 Delivered
Garden Reach Landing Craft Utility o Integrated Platform Management System 2092 8 First shipset Vardha Marine, Handling Tug & 354, for two

Shipbuilders & for Indian Navy to delivered in Norway 355 ships in 2011

Engineers Ltd. 2099 Aug 2014 ABG Shipyard/ 130T BP Anchor o Switchboards/Electricals 355 1 2012

Pipavav Defence Naval Offshore Patrol o Main & Emergency Switchboard 001 to 5 Supply Marnavi, Italy Handling Tug

Offshore and Vessels for Indian Navy o Energy Distribution Centers 005 still to Punj Lloyd Mahesh 1 Barge o Main Switchboard - 1 2012
Hindustan Shipyard 50T BP Tug o Main Switchboard 11173 2 Supply
Engineering Co. Ltd. o Navigation Light Control Panel commence
Limited / Kandla o Distribution Boards & 11174 still to
o Starters
Port Trust o Starters commence

13 14
Major orders Major Orders
Naval Switchboards & Control Systems Commercial Switchboards & Control Systems

Yard/ No. of Year of Yard/ No. of Year of


Customer Type of Vessel/Owner Scope of supply in brief Customer Type of Vessel/Owner Scope of supply in brief
Hull No. Vessels Supply Hull No. Vessels Supply

o Main Switchboard o 690V Main Switchboard


o Distribution Boards o 440V Main Switchboards
o Group Starter panels Converteam UK Flexible Pipelay Vessel o 220V Main Switchboards 602 1 2009
Temba 25T Tug for Indian Navy o Battery chargers 151 4 2012 Ltd./EZRA Lewak Crusader (134m) o 440V & 220CV Emergency Switchboards

o Consoles to to 2013 Marine, Singapore o 440V, 220V AC & 24V DC DBs

o Galley equipment 154 o Distribution Transformers

o Communication equipment o Starters (DOL & Soft)

o Main Switchboard o Main Switchboard

o Group Starter Panels o Emergency Switchboard


ABG o Group Starter Panels
o Distribution Boards & Starters
Shipyard/Tanker 80T Anchor o Distribution Boards (AC & DC) 327 2 2009
Modest 500T Fuel Barge o Cables & accessories 316 to 7 2011 -
Pacific, Handling Tug o Navigation Lighting Panel 328
Infrastructure for Indian Navy o SRE system, Engineers call system, AFDS 322 2013
Singapore o Distribution Transformers
o Luminaries
o Alarm Monitoring System
o Alarm monitoring system
o Main Switchboard
o Main Switchboard
o Emergency Switchboard
o Power Management System
L&T RoRo LoLo Ships o Group Starter Panels 81001 3 2009
Indian Navy P25 o Distribution Boards - 4 2013
Shipyard/Rolldock, o Distribution Boards (AC & DC) 81002
o Changeover Switches
Netherlands o Navigation Lighting Panel 81003
o Transformers
o Shore Supply Box
o Degaussing System
Greatship Global Multirole & ROV o 690V Main Switchboard 314 - 4 2009
o Main Switchboard
Offshore Services Support Vessel o 1050kW Soft starters 344
Mazgaon Dock Destroyers (P15B) o Energy Distribution Centers 12704 4 Supply
Pte Ltd., Multi-Purpose Survey o 690V Main Switchboard 26775 2 2009
Limited for Indian Navy o DA Local Control Panel to still to Sinagapore Vessels o 1050kW Soft starters 26784
o Automated Power Management System 12707 commence o Main Switchboard
o Integrated Platform Management System o Emergency Switchboard
Turnkey Electrical Package including: L&T Shipyard/ Big Lift Cargo Vessel o Group Starter Panels 81007 1 2011
o Main & Emergency Switchboard Big Lift, o Distribution Boards (AC & DC)
ABG Shipyard Cadet Training Ship o Group Starter Panels 397, 3 Supply Netherlands o Navigation Lighting Panel
for Indian Navy o Distribution Boards 398 & still to o Distribution Transformers
o Helo Starting rectifiers 423 commence o TRUs
o Integrated Platform Management System o Alarm Monitoring System
o Integrated Bridge System ABG Shipyard/ 130T BP Anchor o Alarm Monitoring System 343, 344 4 Delivered
Garden Reach Landing Craft Utility o Integrated Platform Management System 2092 8 First shipset Vardha Marine, Handling Tug & 354, for two

Shipbuilders & for Indian Navy to delivered in Norway 355 ships in 2011

Engineers Ltd. 2099 Aug 2014 ABG Shipyard/ 130T BP Anchor o Switchboards/Electricals 355 1 2012

Pipavav Defence Naval Offshore Patrol o Main & Emergency Switchboard 001 to 5 Supply Marnavi, Italy Handling Tug

Offshore and Vessels for Indian Navy o Energy Distribution Centers 005 still to Punj Lloyd Mahesh 1 Barge o Main Switchboard - 1 2012
Hindustan Shipyard 50T BP Tug o Main Switchboard 11173 2 Supply
Engineering Co. Ltd. o Navigation Light Control Panel commence
Limited / Kandla o Distribution Boards & 11174 still to
o Starters
Port Trust o Starters commence

13 14
One-stop Solution
Marine Switchboards
and Control Systems

CBMC/PRD/082016

Larsen & Toubro Limited, Marine Switchboards & Control Systems Regd. Office:
6A North, T.T.C. Industrial Area L&T House, N. M. Marg
Ballard Estate
MIDC, Rabale, Navi Mumbai 400 701. Maharashtra, INDIA Mumbai 400 001, INDIA
Tel : +91 22 27649501 Fax : +91 22 27649301 Tel: +91 22 6752 5792 / 841
Email : ravindra.mahajan@LNTEBG.com
Web : www.Lntebg.com
CIN: L99999MH1946PLC004768

You might also like