Parameter

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Hybrid.zm2 - v0.

0 Tit le

Program information
Author : Author
Project name : Title
Version : 0.0
Module : SR2B121BD
Cycle time in the module : 5 x 2 ms
WATCHDOG action : Inactive
Type of Hardware Input Filtering : Slow (3ms)
Locking of module front panel

Date format : dd/mm/yyyy


Daylight Saving Time change activated
Zone : Europe
Change to Daylight Saving Time : March, Last Sunday
Return to winter time : October, Last Sunday

Author 03/02/2023 1/6


Hybrid.zm2 - v0.0 Tit le

Program diagram

B026
B022 B008
I1 Q1
L26 B027 L39 L39
0 = MAN PLN / INV
1 =AUTO L26 L30 B029 B024 B030
L30 L26 Q2
B021
I2
PLN BYPASS
MANUAL MODE . 0 = PLN, 1 = INV B031

B023
I3
B051 B037
B009 Q3
0 = PLN ByPass L67
L39 L67
1 = PLN + INV
PLN

B035 B036
B062 B042
B038
B019 L39 Q4
I4
B044
B041 INVERTER
Batt. Cadangan
Ena. / Dis.
B045
B077
B000 B006
IB L119
PLN SENSING L119 B049
PLN sensing KALIBRASI B050

B007 B017
B075
B005
Limit Max. PLN volt

Limit Min.PLN volt B016


B001 B074 B012 B015
IC B068
L115 L115 Batt. Cadangan
INVERTER SENSING B010 Set point
INV sensing
KALIBRASI
B065
Limit Max. INV volt B013 B052

B011 B064

Limit Min. INV volt B014 B066


B002 B076
ID B069
Batt. cutoff set
BATT. sensing BATTERYSENSING
KALIBRASI B063

B053
B003
IE
B091
B070 B033 L133
PV sensing

PV SENSING
KALIBRASI B054 B090
B080 B032
L133
L26
L67
B079
B094
L30 ALARM
L119 L67 B092
L115 L134 BATTERY LOW
B082 L134
B085
L39 L136
L26 B096 L119
PLN L115
L133 AUTO mode
L134 L136
PLN
B081
Manual Mode
B095
B086 L30
L119
L115 L39
L135 B093
B087
B097 L135
INVERTER L137
B084 L119
L133 AUTO mode L135 L137
L115
B089

INVERTER
B083 Manual Mode

L119
L115

B088
PARAMETER
L133

Author 03/02/2023 2/6


Hybrid.zm2 - v0.0 Tit le

Physical inputs
Input No Symbol Function Lock Parameters Comment

No parameters 0 = MAN
I1 B022 Contact ---
1 = AUTO
MANUAL MODE . 0 = PLN, 1 = INV
I2 B021 Discrete input --- No parameters

No parameters 0 = PLN ByPass


I3 B023 Contact ---
1 = PLN + INV

No parameters Batt. Cadangan


I4 B019 Contact ---
Ena. / Dis.

Electrical connection at input : 0 - 10 V PLN sensing


Filtered analog
IB B000 --- Cut-off frequency : 50.09 Hz
input

Filtered analog Electrical connection at input : Potentiometer INV sensing


IC B001 --- Cut-off frequency : 50.09 Hz
input
Filtered analog Electrical connection at input : Potentiometer
ID B002 --- Cut-off frequency : 0.06 Hz BATT. sensing
input
Filtered analog Electrical connection at input : Potentiometer
IE B003 --- Cut-off frequency : 0.06 Hz PV sensing
input

Physical outputs
Output No Symbol Function Comment
Normally open
Q1 B008 PLN / INV
contact
Normally open
Q2 B030 PLN BYPASS
contact
Green indicator
Q3 B037 PLN
light
Green indicator
Q4 B038 INVERTER
light

Configurable functions
No Symbol Function Lock Latching Parameters Comment
Numerical Value of the constant : 190
B005 No --- Limit Min.PLN volt
constant
Comparison MIN ON in the zone
B006 --- ---
=< value =< MAX
Numerical Value of the constant : 245
B007 No --- Limit Max. PLN volt
constant
Numerical Value of the constant : 245
B010 No --- Limit Max. INV volt
constant
Numerical Value of the constant : 180
B011 No --- Limit Min. INV volt
constant
Comparison MIN ON in the zone
B012 --- ---
=< value =< MAX

Author 03/02/2023 3/6


Hybrid.zm2 - v0.0 Tit le

No Symbol Function Lock Latching Parameters Comment


Comparison of 2 VALEUR 1 VALEUR 2
B013 --- ---
values
Numerical Value of the constant : 20
B014 No --- Batt. cutoff set
constant
Numerical Value of the constant : 24 Batt. Cadangan
B016 No ---
constant Set point
Comparison of 2 VALEUR 1 VALEUR 2
B017 --- ---
values
Numerical Value of the constant : 90 Min. Volt PV
B032 No ---
constant untuk aktive bypass
Comparison of 2 VALEUR 1 VALEUR 2
B033 --- ---
values
On time : 0H 0M 30S
B041 Timer No No Off time : 0H 0M 0S

On time : 0H 0M 1S
B049 Cyclic timing No No Off time : 0H 0M 1S
Function Li - Duration of flashes : 0H 0M 30S
On time : 0H 0M 0S
B052 Timer No No Off time : 0H 0M 30S

Comparison of 2 VALEUR 1 VALEUR 2


B053 --- ---
values
Numerical Value of the constant : 27 LEVEL BATTERY
B054 No ---
constant READY TO LOAD

B062 RS switching --- --- Priority : RESET has priority

B064 RS switching --- --- Priority : RESET has priority

On time : 0H 0M 1S
B066 Cyclic timing No No Off time : 0H 0M 1S
Function Li - Duration of flashes : 0H 0M 30S
Gain = A/B x Gain: y = (200/255) x + 0 PV SENSING
B070 No --- Range: 0 <= y <= 300
value + C KALIBRASI
Gain = A/B x Gain: y = (255/131) x + 0 INVERTER SENSING
B074 No --- Range: 0 <= y <= 500
value + C KALIBRASI
Gain = A/B x Gain: y = (100/255) x + 0 BATTERY SENSING
B076 No --- Range: 0 <= y <= 100
value + C KALIBRASI
Gain = A/B x Gain: y = (255/131) x + 0 PLN SENSING
B077 No --- Range: 0 <= y <= 500
value + C KALIBRASI

See details below PLN


B079 Text --- ---
AUTO mode
INVERTER
B081 Text --- --- See details below AUTO mode

See details below PARAMETER


B083 Text --- ---

Author 03/02/2023 4/6


Hybrid.zm2 - v0.0 Tit le

No Symbol Function Lock Latching Parameters Comment


On time : 0H 0M 5S
B084 Cyclic timing No No Off time : 0H 0M 5S
Function Li - Continuous flashing

See details below ALARM


B090 Text --- ---
BATTERY LOW
On time : 0H 0M 1S
B091 Cyclic timing No No Off time : 0H 0M 1S
Function Li - Duration of flashes : 0H 0M 30S
PLN
B092 Text --- --- See details below Manual Mode

See details below INVERTER


B093 Text --- ---
Manual Mode

FBD TEXT (Text)

PLN
B079 Text
AUTO mode
D D . M M . Y Y Y Y H H : M M
P L N : * * # 4 * * V a c
I N V : * * # 5 * * V a c
M o d e P L N A U T O
Modification not authorized for #4 B077 Calculation output
Modification not authorized for #5 B074 Calculation output
Modification not authorized for DD.MM.YYYY Date
Modification not authorized for HH:MM Hour

INVERTER
B081 Text AUTO mode

D D . M M . Y Y Y Y H H : M M
P L N : * * # 4 * *
I N V : * * # 5 * *
M o d e I N V E R . A U T O
Modification not authorized for #4 B077 Calculation output
Modification not authorized for #5 B074 Calculation output
Modification not authorized for DD.MM.YYYY Date
Modification not authorized for HH:MM Hour

PARAMETER
B083 Text
P L N : * * # 4 * * V a c
I N V : * * # 5 * * V a c
B A T T : * * # 6 * * V d c
P V : * * # 7 * * V d c
Modification not authorized for #4 B077 Calculation output
Modification not authorized for #5 B074 Calculation output
Modification not authorized for #6 B076 Calculation output
Modification not authorized for #7 B070 Calculation output

ALARM
B090 Text
BATTERY LOW
D D . M M . Y Y Y Y H H : M M
B A T T E R Y L O W
* * # 4 * * V o l t
Modification not authorized for #4 B076 Calculation output
Modification not authorized for DD.MM.YYYY Date
Modification not authorized for HH:MM Hour

Author 03/02/2023 5/6


Hybrid.zm2 - v0.0 Tit le

PLN
B092 Text Manual Mode

D D . M M . Y Y Y Y H H : M M
P L N : * * # 4 * * V a c
I N V : * * # 5 * * V a c
M o d e P L N M A N U A L
Modification not authorized for #4 B077 Calculation output
Modification not authorized for #5 B074 Calculation output
Modification not authorized for DD.MM.YYYY Date
Modification not authorized for HH:MM Hour

INVERTER
B093 Text
Manual Mode
D D . M M . Y Y Y Y H H : M M
P L N : * * # 4 * * V a c
I N V : * * # 5 * * V a c
M o d e I N V E R . M A N U A L
Modification not authorized for #4 B077 Calculation output
Modification not authorized for #5 B074 Calculation output
Modification not authorized for DD.MM.YYYY Date
Modification not authorized for HH:MM Hour

Author 03/02/2023 6/6