Professional Documents
Culture Documents
Method Statement For Drainage System
Method Statement For Drainage System
Automatic Zoom
METHOD STATEMENT FOR DRAINAGE SYSTEM
PRECAST U-DRAIN 600mm x 600mm
CASCADE DRAIN
1. Excavation for cascading drain shall be carried out to the dimensions
as shown in the drawing.
2. To compact base and lay fabric reinforcement A7 raised on chair.
3. To concrete base to a thickness of 125mm and lay half round precast
concrete drain in steps.
3. 225mm thick brickwall complete with plastering on both sides of wall.
PIPE CULVERT CLASS 2 (600mm dia – 1800mm dia)
1. Excavation for pipe culvert shall be carried out to the dimensions and
size as shown in the drawing complete with strutting and formwork.
2. To lay and compact hardcore for bedding and to lay 50mm thc lean
concrete.
3. To lay 150mm thc concrete bedding, the pipes shall than be laid with
ends true to lines and gradient.
4. The annular gap shall be filled with cement sand mortar (1:3) with
sufficient water added to ensure adequate workability.
5. Backfill the pipe culvert with suitable earth stockpiled.