Typical One Way Slab Details: Chair Bar

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

MAIN REINF.

(SEE TABLE)

4
L/
BAR "C" ALONG BAR "B" ALONG
SHORT DIRECTION SHORT DIRECTION MAIN BEAM OR STAIR LANDING BEAM
L 200.00
EXTEND 1 OF EVERY TOP REINF.: 4 - 16mm Ø
BOT. REINF.: 4 - 16mm Ø
3 BARS FULL LENGTH STIRRUPS: 10mm Ø @ 0.15M

350.00
12mm Ø NOSING
BARS

4
L/

TH EE T
(S
IC
MAIN REINF.

KN ABL
DISCONTINUOUS EDGE
(SEE TABLE)

ES E)
DISCONTINUOUS EDGE

S,
t
CONTINUOUS EDGE

CONTINUOUS EDGE
MAIN BEAM OR STAIR LANDING BEAM 200.00
TOP REINF.: 4 - 16mm Ø SUPPORT
BOT. REINF.: 4 - 16mm Ø (BEAM OR R.C. WALL)
STIRRUPS: 10mm Ø @ 0.15M FORMING BARS

350.00
12mm Ø @ 0.30M O.C.

BAR "A" ALONG FOR FOOTING F2' & F3' SECONDARY REINF.
SHORT DIRECTION 10mm Ø @ 0.30M O.C.
CHAIR BAR
SCALE: 1/10 METERS
TYPICAL STAIR DETAIL
SUPPORT
TEMP. BARS ALONG TEMP. BARS ALONG (BEAM OR R.C. WALL)
LONG DIRECTION STAIR SPAN (SEE TABLE)
LONG DIRECTION

A B C D E F

TOP BARS LAYOUT BOTTOM BARS LAYOUT


TYPICAL ONE WAY SLAB DETAILS 2C1

3 2G2
2G1
2G1
S1 2G1
2G2
S1
S1 S1

2G2

2G2

2G2

2G2
NOTES: 2B3 2B3
1. BARS ALONG THE SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG THE LONGER SPAN AT
MIDSPAN AND OVER THE LONGER SPAN AT SECTIONS NEAR SUPPORT (COLUMN LINE).
2. BAR SPACING ALONG COLUMN STRIP CAN BE APPROXIMATELY 1-1/2 TIMES OF THE MIDDLE STRIP BUT IN NO 2B1 2B1 2B1
S1 S1

2G2
CASE GREATER THAN 3 TIMES THE SLAB THICKNESS.

2G2
2B1
S1 S1 S1
BAR "A" ALONG BAR "A" ALONG
LONG DIRECTION SHORT DIRECTION
DISCONTINUOUS EDGE DISCONTINUOUS EDGE 2B3 2B3 S2
2
BAR "B" ALONG
LONG DIRECTION
2G1 2G1 2G1 2G1 2G2
S2
DISCONTINUOUS EDGE

2C1
S1 S1 S1 S1
DISCONTINUOUS EDGE

2B1
CONTINUOUS EDGE

BAR "C" ALONG


CONTINUOUS EDGE

2G2

2G2

2G2

2G2

2G2
SHORT DIRECTION
BAR "B" ALONG
SHORT DIRECTION

2B1 2B1 2B1 2B1

BAR "C" ALONG S2


LONG DIRECTION
S1 S1 S1 S1

2B1
CONTINUOUS EDGE CONTINUOUS EDGE

1
2G2 2G1 2G1 2G1 2C1

TOP BARS LAYOUT BOTTOM BARS LAYOUT


TYPICAL TWO WAY SLAB DETAILS

THIRD FLOOR FRAMING PLAN


SCALE: 1/75 METERS

PROJECT TITLE/ LOCATION: SHEET CONTENT: PREPARED BY: DESIGNED BY: CHECKED & REVIEWED BY: APPROVAL RECOMMENDED BY: APPROVED BY: SHEET NUMBER:
TYP. ONE WAY SLAB DETAIL, TYP. TWO WAY SLAB
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
OFFICE OF THE DISTRICT ENGINEER
LP: LOCAL INFRASTRUCTURE PROGRAM - BUILDINGS
AND OTHER STRUCTURES - MULTIPURPOSE / FACILITIES -
DETAIL, ROOF BEAM FRAMING PLAN, TYP. STAIR
DETAIL, CHAIR BAR S09 S11
CEBU 6th DISTRICT ENGINEERING OFFICE REHABILITATION OF MULTI-PURPOSE BUILDING
A.C. CORTES AVENUE, MANDAUE CITY
(BARANGAY HALL) , BARANGAY TAYUD,
CONSOLACION, CEBU RAYMUND JAY C. ALFORQUE HELEN C. BASALLO ALEXIS MAY M. DY WILMA B. CAMPOS DAISY B. TOLEDO, D.M., ASEAN Eng. 36 83
DRAFTSMAN ENGINEER II CHIEF_PLANNING & DESIGN SECTION ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER DATE: 2020

20HN0102