ULTRASONIC GENERATOR/POWER SUPPLY
LS-E
User’s Manual
ISO 9001
Products are manufactured in ISO
registered facilities.
www.dukane.com/us
Copyright © 2014 Dukane Intelligent Assembly Solutions
2900 Dukane Drive
St. Charles, IL 60174 USA
Notice of Rights:
All rights reserved. No part of this manual including the interior design, cover design and icons may be
reproduced, transmitted or utilized in any form or by any means, electronic, mechanical, photocopying,
recording, or by any information storage and retrieval system, without written permission from Dukane
Corporation.
Notice of Liability:
The information contained in this manual is distributed on an “As is” basis, without warranty. While ev-
ery precaution has been taken in the preparation of this manual, Dukane Corporation shall not have any li-
ability to any person or entity with respect to any liability, loss, or damage caused or alleged to be caused
directly or indirectly by the instructions contained in this manual, or by the hardware products described
herein.
This user’s manual documents product features, hardware, and controls software available
at the time this user's manual was published.
Dukane ultrasonic equipment is manufactured under one or more of the following U.S. Patents:
(* = Inactive)
3,780,926 * 4,131,505* 4,277,710* 5,798,599 5,880,580 6,984,921 7,225,965 7,475,801,
7,819,158 and, 8,052,816
Revision Revision
Number Summary Date
Continued
SECTION 1
Introduction
Generator Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Key Generator Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
tables are numbered separately. The figures use Arabic
sequence numbers (e.g. 1, 2, 3) while the tables use ro-
man sequence numerals (e.g. I, II, III). As an example,
Figure 3- 2 would be the second illustration in Section 3
while Table 3- II would be the second table in Section 3.
Condition Electrical Hearing
or Practice Hazard Protection
SECTION 2
Health and Safety
General Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Plastics Health Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Domestic Power Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Page
6 Dukane Manual Part No. 403-588-00
Section 2 – Health & Safety
Continued
Do Not Wear Loose Clothing or Jewelry - They can Parts being joined ultrasoni-
become caught in moving parts. cally will at times vibrate at
audible frequencies. Wear ear
Stay Alert - Watch what you are doing at all times. Use protectors to reduce annoy-
common sense. Do not operate the press when you are ing or uncomfortable sounds. In addition,
tired or distracted from the job at hand.
ultrasound baffles, sound enclosures, or
Do Not Operate the Equipment - Your judgement or materials that absorb sound may be lo-
reflexes could be impaired while taking prescription medi- cated to surround the system. Ultrasound
cations. If so, do not operate the equipment. Be familiar pressure level could exceed 110dB. See
with warning labels and recommended activity restrictions Ultrasonic Pressure, Table 13-III, Page 120.
that accompany your prescription medications. If you have
any doubt, do not operate the equipment.
emit fumes and/or gases that may be hazardous to the
operator’s health. Proper ventilation of the work station Keep head, hands, limbs and
should be provided where such materials are processed.
body at least six inches (152
Inquiries should be made to the U.S. Department of Labor
concerning OSHA regulations for a particular plastic prior mm) away from an operating
to processing with Dukane ultrasonic equipment. press/thruster. A vibrating,
descending horn can cause burns and/or
crushing injuries.
Electrical Safety
The iQ Series generator provides the operating power
and power returns. Make sure the generator is grounded
properly.
Continued
Page
8 Dukane Manual Part No. 403-588-00
Section 2 – Health & Safety
Electrical Safety
CAUTION
Domestic Power Grounding If you have a two-prong elec-
For safety, the power cords used on this product have a trical receptacle, we strongly
three-wire, grounding-type power cord. Figure 2-1 il- recommend that you replace
lustrates the appropriate electrical outlet to use with the it with a properly grounded
power cord that is included with systems shipped to North three-prong type. Have a qualified elec-
America. trician replace it following the National
Electric Code and any local codes and ordi-
nances that apply. See Figures 2-1 and 2-2.
SECTION 3
Installation
Before Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
When to Use Lockout/Tagout Devices . . . . . . . . . . . . . . . 13
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RFI Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Proper Handling of Cable Slack . . . . . . . . . . . . . . . . . . . . . . 16
Connecting Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Manually Operated Probe System . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Power Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Before Installation
As you plan for the installation of your generator,
please consider these important subjects as listed
below:
Electrical safety hazards
exist inside the generator
chassis. Before making
any internal adjustments
to the generator, apply
a lockout/tagout (LOTO)
device to the generator
chassis.
Continued
Unpacking
Carefully open your shipping container, and make sure
it contains the items shown on the shipping documents. CAUTION
Inspect all items, and report any damage immediately.
Allow 5 inches for air ven-
tilation at the cooling air
Placement inlet and at the exhaust
Generator placement and cable routing should permit air outlet. The fan draws
easy access and not interfere with normal system opera- in fresh air to cool the in-
tion. ternal components, reduce thermal
Allow at least 5 inches (13 cm) of space on both ends of gradients and increase component life.
the generator chassis for air circulation. Allow a 3 inch
space (8 cm) at the rear of the chassis for cable clear- If excessive dust accumulates in the
ance. slots, wipe or vacuum them clean.
See Section 13 - Specifications, for generator drawings.
Do not use compressed air as this
may force the dust inside the chassis.
17.16
[435.86]
5.19
[131.82]
EXHAUST AIR
OUTLET COOLING AIR
INLET
OPERATOR
IN OPERATOR CONTROLS
DISPLAY
[mm]
NOTE
Active Seismic Region Placement -
If the generator will be put in an active
seismic region, please refer to Application
Note 511 at:
http://www.dukane.com/us/DL_ApplData.asp
To m i n i m i z e e l e c t r i -
tioned, proper grounding at the generator power cord is
essential for the effective suppression of electrical noise
cal noise and eliminate
or RFI (Radio Frequency Interference). Every ultrasonic ground currents, ground
generator contains a RFI filter which blocks noise on the the chassis as shown.
AC power line from entering the system control circuitry. Use a STAR configuration
This filter also prevents ultrasonic frequency noise from (illustrated below). Do not
being fed back into the AC power line. In order for the RFI DAISY CHAIN the grounds.
filter to operate properly, it is necessary to correctly ground
the system. Run a grounding wire from the grounding stud
Chassis Grounding
connection to the nearest grounded metal pipe or equiva- Stud Fixed Probe Mount
or 2nd Chassis
lent earth ground, and secure it with a ground clamp. Grounding Stud
See Figure 3-6 on Page 18. #14 Gauge
Recommended protective Stranded or
earth ground connection Solid Wire
wire color: green or green
Proper Handling of Cable Slack with yellow stripe.
3rd Chassis
Grounding
Coil Extra Slack Earth
Ground
Stud
Figure 3-4 Cable Slack Take-up - Correct Figure 3-5 Cable Slack Take-up - Incorrect
Connecting Cables
(Quick Start Guide)
Details about the various system connectors and their pin
assignments are covered in Section 4.
CAUTION
The power cord is equipped
Manually Operated Probe System with a three-prong, ground-
(Hand Probe) ed-type plug for your safety.
1. Ground the generator chassis using the supplied Whenever a two-slot re-
14-Gauge wire, and attach it to the grounding stud: ceptacle is encountered, we strongly
A in Figure 3 -4. recommend that it is replaced with a
properly grounded three-lead receptacle.
2. Attach the hand probe’s HD–15 system input connec-
tor to J2 on the I/O panel: B in Figure 3 -4.
Have a qualified electrician do the
3. Attach high–voltage coaxial cable to J1, the ultra- replacement in accordance with the
sound output connector: C in Figure 3 -4. National Electrical Code and local
4. Connect the AC power cord to the IEC power inlet c odes and ordinanc es. DO NOT
connector on the ultrasonic generator (D in Figure cut of f the power cord grounding
3 -4), and plug the other end into an approved AC out- prong or alter the plug in any way.
let.
Power Cords
Detached Cords
The AC line cords supplied with the standard generators
are matched to the ultrasonic output power rating and the
continent of specified use. See Table 3-I. NOTE
Continent of Use Power Cord Power Refer to Section 11, Options for informa-
Part Number tion about optional features.
200 - 1110 240V, 15A
North America
200 - 1541 240V, 10A
200 - 1111 240V, 16A
Continental Europe
200 - 1542 240V, 10A
Table 3 - I Standard IEC AC Power Cord Part Numbers
Attached Cords
100/120 Volt AC Systems - The power cord (including
strain relief) supplied with the 100/120VAC systems is
permanently attached to the rear of the generator.
240 Volt Systems - High power generators with power
ratings above 2400W also use permanently attached power
cords.
I
MADE IN U.S.A.
J2
J7
C US
UL: 1012:2010
0 LINE VOLTAGE:
200-240 Vac
CSA: C22.2 61010-1-12
IEC: 61010-2012
J9 J3 OUTPUTS
50/60Hz, 10A
-WARNING-
POWER LINE OUTLET
MUST BE GROUNDED J1
DISCONNECT LINE POWER
BEFORE REMOVING COVER
U.S. PATENTS 7,475,801
J4
PE
7,819,158 AND 7,225,965
AC POWER GROUNDING
INLET STUD
ULTRASOUND OUTPUT
SECTION 4
Standard Connections
Page 20
Dukane Manual Part No. 403-588-00
Section 4 – Standard Connections
B H D
DUKANE CORP.
ST. CHARLES IL. 60174
MADE IN U.S.A.
I
C US
UL: 1012:2010
E
0 LINE VOLTAGE:
200-240 Vac
CSA: C22.2 61010-1-12
IEC: 61010-2012
50/60Hz, 10A
-WARNING-
POWER LINE OUTLET
MUST BE GROUNDED
DISCONNECT LINE POWER
BEFORE REMOVING COVER
PE U.S. PATENTS 7,475,801
7,819,158 AND 7,225,965
A C K G F
Figure 4 - 1 Generator Rear Panel
Ethernet/IP Connector
H Ethernet/IP Connector – Provides for communication
between the iQ generator and an automation network.
0
CSA: C22.2 61010-1-12
systems include a non-detachable power cord.
LINE VOLTAGE:
200-240 Vac IEC: 61010-2012
50/60Hz, 10A
-WARNING-
An appropriately rated power cord must be securely at- POWER LINE OUTLET
MUST BE GROUNDED
DISCONNECT LINE POWER
tached to the welding system’s IEC inlet connector. If the PE
BEFORE REMOVING COVER
U.S. PATENTS 7,475,801
correct power cord configuration is not included with the 7,819,158 AND 7,225,965
Page 22
Dukane Manual Part No. 403-588-00
Section 4 – Standard Connections
Continued
Pin 6 (Remote Setup Selection Bit 3 Input) Figure 4 - 4 HD-15F, Generator Input Connector
Pin 6 is the Remote Setup Selection Bit 3, which is the
second most significant bit used to select different weld-
ing setups with an automation control system. This input 1 2 3 4 5
is also used to select different channels when a Multiple
Probe Controller (MPC) Interface option board is in- 6
10
stalled.
11 12 13 14 15
Pin 7 (Remote Setup Selection Bit 4 Input)
(Not used on the basic model generator) Figure 4 - 5 HD-15M, Generator Input Cable
Connector
Pin 7 is the Remote Setup Selection Bit 4, which is
the most significant bit used to select different welding
setups and can only be used with an advanced control
system. This bit will not be used when a Multiple Probe
Controller (MPC) Interface option board is installed.
Continued
Page 24
Dukane Manual Part No. 403-588-00
Section 4 – Standard Connections
Page 26
Dukane Manual Part No. 403-588-00
Section 4 – Standard Connections
when the welding parameters recorded during the Figure 4 - 7 DB-25M, Generator Output Cable
previous welding cycle are outside of the programmed Connector
suspect part limits. This output will be an open circuit
after a welding cycle when a suspect part has not been
detected.
Pin 24 (Isolated Common)
Pin 24 is electrically isolated from chassis ground.
Pin 25 (Not Used)
Pin 25 is an open connection.
Continued
Page 28
Dukane Manual Part No. 403-588-00
Section 4 – Standard Connections
CAUTION
The ultrasonic output from
this connector (that drives the
attached ultrasonic load) is a
very high AC voltage. At high
power levels this can exceed 2 amperes of
current and must be securely terminated
via the ultrasound cable for safe operation.
Use original equipment ultrasound cables
for safe and reliable system operation.
Improperly assembled ultrasound cables
can result in high voltage arcing and will
destroy the ultrasound connectors.
Page 30
Dukane Manual Part No. 403-588-00
Section 4 – Standard Connections
Continued
Page 32
Dukane Manual Part No. 403-588-00
Section 5 – Standard System Status and Controls
SECTION 5
Standard System Status
and Controls
Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Screen Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Page 34
Dukane Manual Part No. 403-588-00
Section 5 – Standard System Status and Controls
INFO Key
Navigation Keys (4)
Active Hot Key Indicator Lighted Power Indicator
Soft Keys (3)
Page 36
Dukane Manual Part No. 403-588-00
Section 5 – Standard System Status and Controls
+
INF
navigation ( ) keys to move the display’s
cursor left or right respectively. ENTER
Press the up and down navigation keys ( + or - ) to scroll EL
NC
through menu lists. Also, use the keys to CA Navigation Key (4)
move to a digit and change the value of a selected digit
with the + or - keys. Figure 5-4 Navigation Keys (4), with Enter, Info and
Cancel
ENTER Key
Press ENTER to confirm and store a selection in memory.
SYSTEM INFO INFO MENU ONLINE
Example: After entering a time value, press ENTER.
NOTE
For more information about the INFO
Soft Keys Bordering the menus, please see Section 6 - Operation.
Display (3)
Use the three keys bordering the left side of the display to
make selections from the choices shown on the display.
ONLINE
AMPLITUDE 100%
Active Keys WELD
Page 38
Dukane Manual Part No. 403-588-00
Section 5 – Standard System Status and Controls
CAUTION
Lighted Power Indicator
This front panel lighted power indicator glows after the If an alarm indicates there is an
rear panel AC power switch/circuit breaker is turned
overload fault, verify that the
ultrasonic stack is not damaged.
ON:
Screen Basics
Making Selections
Figure 5-8 below shows there are several ways to show
that an item has been selected:
• An area of white highlights a selected item.
DISTANCE
ENERGY TIMETIME
0.0000 in ENERGY
> ENERGY
0J > DISTANCE
PEAK POWER
White area high- MAX
MAX TIME POSITION
lights selected item 30.000s
30.000s GROUND DETECT
SECONDARY PRESS ENTER
PRESS ENTER TO
TO ACCEPT
ACCEPT
WELD CONTROL PRESS CANCEL TO ABORT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Interpreting
On-screen Arrows
Arrows pointing up and down, give visual cues that more
text is available in the direction the arrow points. An
example is shown below in Figure 5-9. For this screen,
the + and - (up or down) navigation keys are used to
move in the direction of the on-screen arrow.
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Page 40
Dukane Manual Part No. 403-588-00
Section 5 – Standard System Status and Controls
Continued from Previous Page
Setup Identification
Setup identification can be seen at the top of the screen
as shown in the figure below.
Page 42
Dukane Manual Part No. 403-588-00
Section 6 – Operation
SECTION 6
Operation
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Start-up Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Stopping the Weld Cycle . . . . . . . . . . . . . . . . . . . . . . 47
Using the Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
AMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
PRE-WELD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
WELD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
POST-WELD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
LIMITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
SETUPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
OPERATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
LIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
IN CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Using the INFO Menus . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Page 44
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Overview NOTE
The iQ Series generator, model LS-E, is typically part of a
The acoustic stack, and tooling will require
system. Major components of the system would be:
their own individual adjustments as those
• iQ generator, components are integrated into your par-
• Probe and horn, or hand probe and horn,or ticular system.
• Customer supplied automation equipment
Helpful information on a wide variety of
including probe and horn.
assembly equipment, processes and
Tthe user controls nearly all aspects of the welding techniques can be found at the Dukane
process through the front panel of the iQ LS-E generator. website:
http://www.dukane.com/us/PPL_upa.htm
Continued
Start-up Sequence
After all connections have been completed, (ON)
1. Push the rear panel AC breaker switch to ON.
(OFF)
The generator begins its self-diagnostics sequence.
Lighted Power
Indicator
AUTO
DUKANE 01 CORPORATION/IAS
SETUP #01DIVISION ONLINE
iQ LS-E SERIES PART COUNT:GENERATOR
ULTRASONIC 0
WELD
Model# 20HB1201W TIME : 0.000s
Serial # xxxxxx
ENERGY: 0J
Front Panel Code v1.xx.xx
PEAK POWER : 201xxxxxxxxxxx 0W
Motherboard Code v3.xx.xx
DISTANCE 201xxxxxxxxxxx 0in
www.dukane.com/us
PROCESS
Boot Code MB vxx.xx / FP vxx.xx
STATISTICS
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
NOTE
A welding cycle cannot be started when the
mode is OFFLINE because the ultrasound
output signal is disabled.
Continued
Page 46
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Continued from Previous Page
4. The start-up sequence is finished when the power LED
turns a steady GREEN and the OPERATE screen is
displayed.
See Figure 6-3.
Emergency Conditions
Manual System
Press OFFLINE to stop the ultrasound signal. This
may be done under any condition.
Automated System
Customer-supplied external controls provide the
means to stop the cycle for an automated system.
An auxiliary cable connects these external controls
to the iQ generator at connector J2.
Control input labeled, “Automation Cycle Stop
Input” (Pin 15) when activated will stop the weld
cycle if configured as “End of Weld”.
Menu Access
Page 66
Hot Keys INFO
Weld
System Info
Page 49 AMP Afterburst (If Afterburst is enabled.)
Start (If Trigger by Power is enabled.)
Regional Settings
Operating Mode
Advanced Settings
Page 52 PRE-WELD
Trigger
Time
Page 55 WELD Energy
NOTE
Peak Power
The unique hardware configuration of
the generator determines what menus
Hold are available.
Page 56 POST-WELD
Afterburst
iQ System
Erase Setup
Page 48
Dukane Manual Part No. 403-588-00
Section 6 – Operation
NOTE
For all menus - When a button is pressed to access the menu, the last accessed
parameter will be selected and ready to change if applicable.
Example: If the PRE WELD button is pressed, and the MODE was the setting
last accessed in that menu, then MODE is selected and ready to change.
NOTE
On screen Prompts - Watch for and follow on screen prompts where they appear.
AMP
The menu in Figure 6-5 is the default display showing ONLINE
Continued
shown to the right. This menu has START as the top soft AMPLITUDE 100%
WELD
key. The setting last accessed is selected and ready to
be changed. In the example shown in Figure 6-7, that is PRESS ENTER TO ACCEPT
AFTERBURST
START > AMPLITUDE. PRESS CANCEL TO ABORT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
NOTE
Amplitude Range = 20 -100%
NOTE
To enable Trigger by Power:
1. PREWELD button is pressed.
2. Mode is iQ Controlled Probe.
3. TRIGGER soft key has been pressed,
Press ENTER.
4. Select POWER, and press ENTER.
5. Select POWER parameters (AMPLITUDE,
POWER, and MAX TIME)
Continued
Page 50
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Continued from Previous Page
Remote Amplitude Board
If a remote amplitude board is detected, the choices shown
in Figures 6-8, 6-9 and 6-10 to the right are displayed. START ONLINE
iQ AMPLITUDE
AMPLITUDE
100%
100%
WELD
WELD REMOTE AMPLITUDE DISABLED
PRESS ENTER
PRESS TO
ENTER TOACCEPT
ACCEPT
PRESS CANCEL
PRESS TOTOABORT
CANCEL ABORT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
START ONLINE
iQ AMPLITUDE
AMPLITUDE
100%
100%
WELD
WELD REMOTE AMPLITUDE DISABLED
START ONLINE
iQ AMPLITUDE 100%
100%
AMPLITUDE
WELD
WELD REMOTE AMPLITUDE ENABLED
PRESS ENTER TO ACCEPT
PRESS ENTER TO ACCEPT
PRESS CANCEL
PRESS CANCELTO
TOABORT
ABORT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
PRE-WELD
The PRE WELD menu is shown in Figure 6-11. The se- MODE ONLINE
AUTOMATED PROBE
lected mode is highlighted (AUTOMATED PROBE). To iQ CONTROLLED PROBE
change to a different mode, move arrow to desired mode, MANUAL PRESS
AUTOMATED PRESS
and press ENTER. The PROBE DELAY soft key is avail-
PROBE DELAY
able in this mode. PRESS ENTER TO SELECT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
MODE ONLINE
TIME 0.0000s
PROBE DELAY
PRESS ENTER TO SELECT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
PROBE DELAY menu is shown in Figure 6-12 at right. Figure 6-12 Pre Weld Menu, Probe Delay
NOTE
PROBE DELAY is only available in
AUTOMATED PROBE MODE.
Continued
Page 52
Dukane Manual Part No. 403-588-00
Section 6 – Operation
TRIGGER
PRESS ENTER TO SELECT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
MODE ONLINE
TYPE DISABLED
TRIGGER
PRESS ENTER TO CHANGE
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
MODE ONLINE
DISABLED
POWER
Making the selection of trigger type is shown in Figure
6-15.
TRIGGER
PRESS ENTER TO CHANGE
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
MODE ONLINE
TYPE POWER
AMPLITUDE 100%
POWER 0W
TRIGGER BY POWER has been chosen as the trigger MAX TIME 0.000s
type as shown in Figure 6-16.
TRIGGER
PRESS ENTER TO CHANGE
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Continued
Page 54
Dukane Manual Part No. 403-588-00
Section 6 – Operation
WELD
The WELD menu seen in Figure 6-19, shows the message ONLINE
that is displayed if the MODE was set to AUTOMATED
WELD CONTROLLED BY AUTOMATION
PROBE.
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
TIME
ENERGY > TIME
TIME ONLINE
0.000s > ENERGY
The WELD menu shown in Figure 6-21 has the MODE 0J ENERGY
PEAK POWER
set to iQ CONTROLLED PROBE. This probe generator MAX TIME
30.000s
supports time and energy.
SECONDARY PRESS
USE +/-ENTER TO ACCEPT
TO SELECT
WELD CONTROL PRESS
PRESSCANCEL TO
ENTER TO ABORT
CHANGE
This is the only choice that has a SECONDARY WELD PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
CONTROL soft key. Because energy is the primary weld
method, ENERGY is not a possible choice as the second- Figure 6-21 Weld Menu, Mode: iQ Controlled Probe,
ary choice. Probe Generator has Time and Energy
TIME
POWER > TIME WELD CONTROL
SECONDARY ONLINE
The menu shown in Figure 6-22 at the right appears when 0.000s
0W ENERGY
TIME
the MODE is iQ CONTROLLED PROBE. A secondary MAX TIME > PEAK POWER
30.000s
weld control, PEAK POWER has been selected.
PRESS ENTER
USE +/- TO ACCEPT
TO SELECT
PRESS
PRESSCANCEL TOCHANGE
ENTER TO ABORT
MAX TIME, a secondary parameter, can be programmed AMP
PRE
WELD
POST
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
in its range of 0-30.00 seconds.
Figure 6-22 Weld Menu, Mode: iQ Controlled Probe
with Secondary Weld Control
POST-WELD NOTE
Hold HOLD and AFTERBURST are not avail-
able as soft keys if AUTOMATED PROBE
MODE was selected in the PRE WELD
menu.
DISTANCE
MAX TIME
AFTERBURST
POSITION 0.000s
30.000s GROUND DETECT
PRESS ENTER TO ACCEPT
PRESS ENTER TO ACCEPT
PRESS
PRESSCANCEL
CANCEL TO ABORT
TO ABORT
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
NOTE
When the POST WELD key is pressed, the
parameter last accessed is selected, and
it is ready to be changed.
Continued
Page 56
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Continued from Previous Page
Afterburst
The menu shown in Figure 6-25 at the right appears if the TIME
HOLD > TIME ONLINE
ONLINE
0.000s ENERGY
AFTERBURST DISABLED
AFTERBURST soft key has been pressed in the POST
AFTERBURST
WELD menu.
USE +/- TO SELECT
PRESS ENTER TO CHANGE
PRESS ENTER TO CHANGE
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
LIMITS
BAD
BAD WELD
TIME TIME
>>TIME ONLINE
ONLINE
DISABLED
DISABLED
The LIMITS menu seen in Figure 6-27, shows what is ENERGY
Bad Limits
BAD
DISABLED
DOWNSTROKE
TIME TIME ONLINE
ONLINE
DISABLED TRIGGER DELAY TIME
To enable Bad Limits, press the BAD soft key and select >
BAD PART
TIME
LIMIT
ENABLED. The display will appear like the one in Figure SUSPECT
ENABLED
DISABLED
ENERGY
HOLD TIME
6-28. TOTAL CYCLE TIME
DISPLAY
ENABLED
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Suspect Limits
To enable Suspect Limits, press the SUSPECT soft key,
and select ENABLED. The display will appear like the one
shown in Figure 6-29.
BAD
DISABLED
DOWNSTROKE
TIME TIME ONLINE
ONLINE
DISABLED DOWNSTROKE
SUSPECT DIST
PART LIMIT
> TIME
SUSPECT
ENABLED
DISABLED
ENERGY
WELD DISTANCE
WELD END POSITION
DISPLAY TOTAL CYCLE TIME
ENABLED
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Continued
Page 58
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Continued from Previous Page
Setting Upper and Lower Limits
BAD
UPPER LIMIT
DISABLED
DOWNSTROKE
TIME TIME
TIME ONLINE
ONLINE
DISABLED DOWNSTROKE DIST
Setting upper and lower limits for both bad and suspect 30.000s SUSPECT
SUSPECT
> TIME
PART
PART LIMIT
LIMIT
parts uses the same procedure.
SUSPECT
ENABLED
LOWER LIMIT
DISABLED
ENERGY
WELD DISTANCE
0.000s WELD END POSITION
As an example, Figure 6-30 to the right shows how the DISPLAY
DONE
TOTAL CYCLE TIME
Press the UPPER LIMIT soft key, and enter a value using
the +/- keys to choose digits. Press ENTER when finished.
When limits have been entered, Press the DONE soft key. NOTE
TIME has a range of 0.000 seconds to
Continue in this way setting upper and lower limits for any 30.000 seconds.
other parameters in your process. 30.000s is the upper limit for this parameter.
SETUPS
Setup Control
IQ SYSTEM > SETUP CONTROL ONLINE
NAME SETUP
The SETUPS menu seen in Figure 6-31, shows that iQ COPY SETUP
ERASE SETUP
SYSTEM is the default setup control setting for this menu. AUTOMATION
SELECT SETUP
SELECT SETUP is the bottom soft key in this case.
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
If AUTOMATION is selected, the bottom soft key would
be: EDIT SETUP. Figure 6-31 Setups Menu, Default Display
Press SELECT SETUP, and a screen similar to the one SELECT SETUP > # 1 - SETUP# 1 ONLINE
# 2 - SETUP# 2
shown in Figure 6-32 to the right is displayed. # 3 - SETUP# 3
# 4 - SETUP# 4
# 5 - SETUP# 5
When the > is next to the desired setup, press the SELECT # 6 - SETUP# 6
# 7 - SETUP# 7
SETUP soft key, or the ENTER key.
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Then, the previous screen will be displayed.
Figure 6-32 Setups Menu, Select Setup
Pressing CANCEL would display the previous screen
without any setup being chosen.
Name Setup
SETUP NAME SETUP CONTROL ONLINE
SETUP #1 > NAME SETUP
The menu shown to the right in Figure 6-33 is displayed COPY SETUP
ERASE SETUP
when the > is moved to NAME SETUP.
The name of the current setup that is being edited (depen- ERASE NAME
PRE
dent on SETUP CONTROL) is highlighted and ready AMP
WELD
POST
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
for editing.
Figure 6-33 Setups Menu, Name Setup
Pressing ENTER saves the name.
Continued
Page 60
Dukane Manual Part No. 403-588-00
Section 6 – Operation
COPY SETUP
The current setup being used or edited is displayed under
PRE
POST
COPY FROM. AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Copy From
SELECT SETUP > # 1 - SETUP# 1 ONLINE
# 2 - SETUP# 2
When the COPY FROM soft key is pressed, a list of setups, # 3 - SETUP# 3
as shown in Figure 6-35 to the right, is displayed. #
#
4
5
-
-
SETUP#
SETUP#
4
5
# 6 - SETUP# 6
Use the + and - keys to scroll through the list. # 7 - SETUP# 7
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Press ENTER to make the setup the COPY FROM selec-
tion. Figure 6-35 Setups Menu, Copy From/To Setup
Copy To
SETUP COPIED
Press ENTER to make the setup the COPY TO selection.
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
When the COPY SETUP soft key is pressed, the screen
shown in Figure 6-36 is displayed - for about 5 seconds. Figure 6-36 Setups Menu, Setup Copied
Confirmation
The next screen displayed is the COPY SETUP screen as
shown in Figure 6-34 above.
Continued
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
The current setup or all setups can be erased.
Figure 6-37 Setups Menu, Erase Setup
Confirm Erase
When YES is pressed, the screen shown in Figure 6-39 PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
is displayed for about 5 seconds. Then, the ERASE setup
menu is shown.
Figure 6-39 Setups Menu, Confirm Erase
Page 62
Dukane Manual Part No. 403-588-00
Section 6 – Operation
OPERATE
Name of setup being edited if in
Automation Mode, Otherwise the
setup is in use.
Process Characteristics
Continued
BACK
Percentages shown are of the total part count.
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Example: Number of GOOD parts divided by the total
PART COUNT multiplied by 100 equals the percentage Figure 6-41 Operate Screen - 2
of GOOD parts.
Page 64
Dukane Manual Part No. 403-588-00
Section 6 – Operation
LIVE
When the LIVE hot key is pressed, the display as shown
in Figure 6-42 to the right is seen. AUTO 01 ONLINE
SETUP #01
IN CYCLE IN CYCLE
AUTO 01 ONLINE
When the LIVE hot key has been pressed, and the genera- SETUP #01
tor is in cycle, the screen shown in Figure 6-43 is dis- AMPLITUDE 100%
POWER 0W
played. OPERATING FREQUENCY 19,900Hz
DISTANCE 0.0000in
The screen shows the current value of the parameters PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
shown.
Figure 6-43 In Cycle Screen
TEST
When the TEST soft key has been pressed, and the AUTO 01 TEST ONLINE
generator is online, the screen shown in Figure 6-44 is SETUP #01
ADVANCED SETTINGS
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
DUKANE CORPORATION/IAS
DUKANE CORPORATION/ DIVISION
IAS DIVISION ONLINE
ONLINE
iQLE
iQ xx SERIES
SERIESULTRASONIC
ULTRASONIC GENERATOR
GENERATOR
SYSTEM INFO - To display information about Model# 20HS2401ZP5
XXXXXXXXX Serial# XXXXXX
Model# Serial# 236853
the generator hardware, press the SYSTEM INFO Front Panel
Front Panel Code
Codev1.XX.XX
v1.00.00 XXXXXXXXXXXXXX
button. Figure 6-46 shows an example display of that Motherboard Code
Motherboard Codev3.XX.XX
vXX.XX.XX XXXXXXXXXXXXXX
www.dukane.com/us
www.dukane.com
information. Boot Code:
Boot Code MBMBvXX.XX
v1.03 // FP
FPvXX.XX
v1.00
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
BACK
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Continued
Page 66
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Continued from Previous Page
ADVANCED SETTINGS - This part of the
INFO menu gives access to the three sub-menus,
Adv Process Control, System Status IO, and
Miscellaneous and their menu items as shown below in
Figure 6-49.
Frequency Tracking
Free Run Frequency CAUTION
Scan Stack
• Adv Process Control Freq Lock and Hold Modifying Advanced Set-
System Freq Limits tings may damage the unit
Ramp Up Time or the ultrasonic stack.
Ramp Down Time
Buzzer
• Miscellaneous External Control
Restore Factory Defaults
Continued
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Continued
Page 68
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Continued from Previous Page
Adv Process Control Sub-menu Items
The six sub-menu items - Frequency Tracking, Free
Run Freq, Freq Lock and Hold, System Freq Lim-
its, Ramp Up Time, and Ramp Down Time and their ADV PROCESS CONTROL Online
corresponding displays are shown to the right and on the TRACKING
next page. Descriptions are provided below.
ENABLED > FREQUENCY TRACKING Disabled
FREE RUN FREQ 20000Hz
TRACKING Disabled
1) Frequency Tracking DISABLED
FREQ LOCK AND HOLD
SYSTEM FREQ LIMITS Normal
When enabled, at the end of each cycle the operating RAMP UP TIME 0.150s
RAMP DOWN TIME 0.000s
frequency is applied to the Free Running Frequency
setting. It’s based on a 16 point average. Therefore,
after 16 cycles, the actual operating frequency will be
the Free Running Frequency setting. If the generator
FREE RUN ADV PROCESS CONTROL Online
has not been cycled for a minimum of 5 minutes, the
19900HZ FREQUENCY TRACKING Disabled
generator will request that the stack be scanned in order > FREE RUN FREQ 20000Hz
to verify the optimum Free Running Frequency setting. SCAN Disabled
FREQ LOCK AND HOLD
STACK
For more information about Frequency Tracking, refer SYSTEM FREQ LIMITS Normal
RAMP UP TIME 0.150s
to our Application Note 513 on the Dukane website at: 0.000s
RAMP DOWN TIME
http://www.dukane.com/us/DL_ApplData.asp
2) Free Run Freq
Free run is the frequency at which the generator Figure 6-53 Advanced Process Control Sub-menu
drives the ultrasound output pulses until a valid Items A
feedback signal is detected. Typically this value
should be below the operating frequency of the stack
Adjust manually within the prescribed limitations for
SCAN STACK Online
your particular generator model. SCAN
PRESS SCAN TO TEST STACK FOR
Scan Stack OPTIMAL FREQUENCY, PRESS BACK
TO RETURN TO PREVIOUS SCREEN
To scan the stack: Scroll to Free Run Frequency
in the displayed list and select the Scan Stack soft BACK
key. Follow the displayed instructions. See Figure AMP
PRE
POST
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
WELD
6-54 to the right.
Figure 6-54 Scan Stack - 1
When scan is complete, the scan results appear as in
the example shown in Figure 6-55.
FREQUENCY CHECK Online
For more detail on the Scan Stack feature please SCAN
refer to our website to download: PRESS SCAN TO TEST STACK FOR
OPTIMAL FREQUENCY, PRESS BACK
Application Note 512 at http://www.dukane.com/ TO RETURN TO PREVIOUS SCREEN
us/DL_ApplData.asp RESONANT FREQUENCY = 20096
BACK
until the end of the weld. PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Enable or Disable this feature.
Figure 6-55 Scan Stack - 2
Continued
200Hz.
Normal, Narrow, or Wide - Enter Upper and TIMERESTOREADV PROCESS
> ADV CONTROL Online
ONLINE
CONTROL
PROCESS
Lower Limits within prescribed limitations for DEFAULTS FREQUENCY
0.150s PHASE SHIFTTRACKING DISABLED 0°
FREE RUN FREQ
FREQ
your particular generator. FREE RUN
FREQ LOCK AND
AND HOLD
HOLD
20000Hz
FREQ LOCK DISABLED
Manual - In Manual mode the user sets the upper SYSTEM FREQ LIMITS
SYSTEM FREQ
RAMP UP TIME LIMITS NORMAL
and lower frequency limits. To be valid, the set- > RAMP
RAMP UP TIME
DOWN TIME 0.150s
RAMP DOWN TIME 0.000s
tings must be within the maximum and minimum
values for the generator and at least 25Hz greater
than the "upper" free run frequency and 25Hz less TIMERESTORE ADV PROCESS
> ADV CONTROL
PROCESS CONTROL Online
ONLINE
than "lower" free run frequency. DEFAULTS FREQUENCY
0.000s PHASE SHIFTTRACKING DISABLED 0°
FREE RUN FREQ
FREQ
Manual - Enter Upper and Lower Limits. FREE RUN
FREQ LOCK AND HOLD
20000Hz
FREQ LOCK AND HOLD DISABLED
SYSTEM FREQ LIMITS
SYSTEM FREQ
RAMP UP TIME LIMITS NORMAL
RAMP UP
RAMP TIME
DOWN TIME 0.150S
> RAMP DOWN TIME 0.000s
Page 70
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Continued from Previous Page
6) Ramp Up Time
Ramp up time increases the amplitude linearly in NOTE
the programmed time period at the start of the weld, Ramp Down Time
from zero to the programmed amplitude level. This
brings the stack up to operating amplitude smoothly
Ramp Down Time extends the service life
preventing shock stress.
of complex acoustic stacks by minimizing
stresses encountered during the process
Factory setting is 0.150 seconds. of shutting off the ultrasound. It is espe-
Range is 0.000 to 1.250 seconds. cially recommended for very large horns,
or when the ultrasound is shut off in air.
7) Ramp Down Time
Ramp down time decreases the amplitude linearly to
zero in the programmed time period following the
end of the weld, when ultrasound is shutting off.
Factory setting is 0.000 seconds.
Range is 0.000 to 0.250 seconds.
RESTORE >SYSTEM STATUS I/O ONLINE
SYSTEM STATUS I/O Sub-menu DEFAULTS AUTO START INPUT SOLID STATE
AUTO STOP INPUT END OF CYCLE
J3 PIN 4 E-STOP
The SYSTEM STATUS I/O sub-menu is displayed in J3 PIN 5 HOLD
Figure 6-57. OUTPUT DURATION MAINTAINED
YES ONLINE
ARE YOU SURE YOU WANT TO RESTORE
ALL SYSTEM STATUS
If the RESTORE DEFAULTS key is pressed while, NO I/O SETTINGS TO DEFAULT VALUES?
the SYSTEM STATUS I/O sub-menu is displayed, the
screen shown in Figure 6-58 is seen.
ONLINE
4) J3 Pin 5
Choose the output signal for J3 Pin 5:
ONLINE
SYSTEM STATUS I/O
Hold, In Cycle, or In Cycle No AB HOLD
AUTO START INPUT SOLID STATE
AUTO STOP INPUT END OF CYCLE
IN J3 PIN 4 E-STOP
CYCLE
> J3 PIN 5 HOLD
OUTPUT DURATION MAINTAINED
5) Output Duration IN CYCLE
NO AB
Choose either Maintained, or 100mS Pulse.
MAINTAINED SYSTEM STATUS I/O ONLINE
AUTO START INPUT SOLID STATE
100 ms AUTO STOP INPUT END OF CYCLE
PULSE J3 PIN 4 E-STOP
When > is next to OUTPUT DURATION, and the J3 PIN 5 HOLD
> OUTPUT DURATION MAINTAINED
down key (minus) is pressed, the next sub-menu
item for SYSTEM STATUS I/O appears. This is
NETWORK.
Continued
Page 72
Dukane Manual Part No. 403-588-00
Section 6 – Operation
Network Settings
The Network Settings screen as seen in Figure 6-61 has
five elements:
DHCP NETWORK ONLINE
1. DHCP - These initials stand for Dynamic Host Configu- ENABLED ENABLED
> DHCP
ration Protocol. The protocol was established for assigning IP ADDRESS 172. 16.100.111
DHCP
dynamic IP addresses to devices on a network. DISABLED SUBNET MASK 255.255 0. 0.
EIP CONN: NONE
DHCP is enabled by default, this ensures no network
address contention will happen in the event that the
generator is plugged into a network before the user assigns
Figure 6-61 Network Settings
a static address. Most commonly DHCP is disabled and
a statically assigned IP addresses are used in industrial
networks.
When DHCP is enabled, the static IP address/subnet mask
setting is ignored. You may need to contact your network
administrator if you do not know whether to enable or
disable DHCP.
2. IP ADDRESS - This Internet Protocol address is a
number unique to a piece of equipment acting as an
identifier when the equipment is connected to a network.
This field is editable when DHCP is disabled.
You may need to contact your network administrator if
you do not know what address to use.
3. SUBNET MASK - defines the subset of the
network address which applies to the locally defined
subnetwork. Generally, this setting must match other
entities on the network. This field is editable when DHCP
is disabled.
You may need to contact your network administrator if
you do not know what mask to use.
4. EIP CONN: - Indicates the IP address of the
controlling Ethernet/IP connection.
5. LINK: - Indicates the state of the Ethernet link. (up/
down (plugged in or not), 10/100 Mbps, half/full duplex)
ONLINE
Page 74
Dukane Manual Part No. 403-588-00
Section 6 – Operation
ALARMS
Terminology: Alarm refers to any fault, or error the gen-
NOTE
erator might produce.
Go to this web address:
An alarm condition may occur. Figure 6-63 shows the http://www.dukane.com/easyalarm
format for a typical alarm display. for more information about the alarm’s cause
and remedy.
The list below gives general reference information for
each alarm condition.
POWEROVERLOAD
FREQUENCY NOT OK FAULT ONLINE
FAULT 1 Online
FAULTFault ID # Uxxx
ID # Uxxx Serial # xxxxxx
SERIAL # xxxxxx
VISIT WWW.DUKANE.COM/EASYFAULT
VISIT www.dukane.com / easyalarm FORFOR
FAULT INFORMATION
FAULT AND TROUBLESHOOTING TIPS,
AND TROUBLESHOOTING
OR CONSULT YOUR MANUAL
TIPS OR CONSULT YOUR MANUAL
PRESS ENTERPRESS
TO CLEAR
ENTER TO CLEAR
PRE
POST
AMP
WELD
WELD
WELD
LIMITS
SETUPS
OPERATE
LIVE
Page 76
Dukane Manual Part No. 403-588-00
Section 7 – Process Control Settings
SECTION 7
Process Control Settings
Page 78
Dukane Manual Part No. 403-588-00
Section 7 – Process Control Settings
Page 80
Dukane Manual Part No. 403-588-00
Section 8 – System Operational Testing
SECTION 8
System Operational Testing
Page 82
Dukane Manual Part No. 403-588-00
Section 8 – System Operational Testing
1. Plug in the AC line cord to the correct AC power out- MADE IN U.S.A.
0 LINE VOLTAGE:
CSA: C22.2 61010-1-12
IEC: 61010-2012
tion.
BEFORE REMOVING COVER
PE U.S. PATENTS 7,475,801
7,819,158 AND 7,225,965
System Test
To test the system’s ultrasound operation, perform the
CAUTION
following steps.
1. For this test, the generator must be ONLINE. Make Any unusually loud noise
sure ONLINE appears in the upper right corner of the from the probe stack in-
display. dicates that it has been
improperly assembled.
2. Connect a probe to the generator ultrasonic output.
Check the probe stack
3. Place the probe so that the tip of horn is not in contact for correct assembly
with anything. If you are using a hand probe, you may a n d p r o p e r t o r q u e.
feel a slight vibration or sensation in your hand. This
is normal. There should not be any loud or unusual
noise.
4. Momentarily press the TEST key (C in Figure 8-3). C
D
5. The first segment LED of the SYSTEM POWER
OUTPUT LEVEL bar graph (D in Figure 8-3) turns
white. The probe will operate as long as the TEST key
is pressed.
6. When the TEST key is released, the SYSTEM POW-
ER OUTPUT LEVEL bar graph turns off (no white
in the bar graph area). This test cannot be performed
with the generator OFFLINE. Figure 8 - 3 System Test
Page 84
Dukane Manual Part No. 403-588-00
Section 8 – System Operational Testing
Page 86
Dukane Manual Part No. 403-588-00
Section 9 – Troubleshooting
SECTION 9
Troubleshooting
No Ultrasonic Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Operate Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Welding Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Weak Welds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Excess Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Inconsistent Welds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
No Ultrasonic Output
Probe
Make sure that the probe coaxial cable is connected to the
generator ultrasonic output connector J1. Basic generator
models have the BNC connector on the rear panel. Also,
make sure the probe stack was properly assembled.
Cables
Make sure that both the U/S coaxial and system I/O cables
are securely connected. You must activate the ultrasound
activation input to Pin 8 on the system input HD-15
connector either by the hand probe’s control cable or
with a custom automation input signal. Refer to Table 4-I,
Generator Input Signals, for details.
Operate Input 1 2 3 4 5
If you are using a hand probe, make sure the control cable
6
and adapter cable are securely connected to the system I/O 10
connector. The trigger switch on the hand probe activates
the ultrasonic output through the control cable. 11 12 13 14 15
Figure 9- 1 Cable End of System I/O Connector
Welding Problems
Weak Welds
Weak welds, or underwelding, is caused by insufficient
energy being transmitted to the part. You can increase
the weld pressure, increase the weld time or change to a
higher gain booster to increase the amplitude to increase
the energy delivered to the weld.
Excess Flash
The energy director may be too large. You can try to
reduce the weld pressure and/or weld time. The parts
may have too much shear interferences or a nonuniform
joint dimension.
Inconsistent Welds
Variations in plastic due to filler materials and moisture
absorption may lead to inconsistent welds. Fillers can
be especially troublesome if they are not uniformly
distributed, the content is too high or it contains too
much or poor quality regrind or degraded plastic.
Check the horn and fixture alignment and parallelism.
Check the alignment of the mating parts, shifting during
welding or residual mold release on the parts.
Try welding by energy. This eliminates many
inconsistencies. There should be no unusual or loud
noise from the acoustic stack. If there is, disassemble
the stack and reassemble.
Exchange the probe with another unit to see if the problem
disappears. If not, exchange the generator with another
unit to try and isolate the problem.
The horn amplitude may not be uniform if it has been
machined, altered or damaged. All of these will change
the resonant frequency of the horn. You can have the
horn analyzed.
Page 90
Dukane Manual Part No. 403-588-00
Section 10 – Maintenance
SECTION 10
Maintenance
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Control Keys/Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Sheet Metal Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
I/O Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
AC Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Page 92
Dukane Manual Part No. 403-588-00
Section 10 – Maintenance
Display WARNING
Do not apply any pressure to the display.
Never operate the gen-
erator with the cover
Control Keys/Buttons off. This is an unsafe
Control keys/buttons will respond to firm, gentle finger practice and the high
pressure. Please do not use sharp objects on the keys/ voltage present may
buttons. cause injury.
Chassis
Sheet Metal Cover
The cover is preformed to fit over the chassis and has
protective grills over the cooling air vents. Keep the cover
on at all times because there are high voltages present
which could cause injury. The internal case also contains
capacitors which continue to hold a high electrical charge,
even after the power is shut off.
Page 94
Dukane Manual Part No. 403-588-00
Section 11 - Options
SECTION 11
Options
Page 96
Dukane Manual Part No. 403-588-00
Section 11 - Options
240V Systems
Generators with power ratings above 2400 Watts also
have fixed power cords.
10 6
15 14 13 12 11
Page 98
Dukane Manual Part No. 403-588-00
Section 11 - Options
Multi- Probe Control (MPC) In addition to completing these first four or six steps,
complete the two steps below to wire the MPC Control
Interface and EtherNet/IP Inputs/Status Outputs as described.
Part Number - 110- 4251 Details about the various system connectors and their
pin assignments are covered below.
This optional module combines the EtherNet/IP and
MPC interfaces. See Pages 31-32 for information on the
EtherNet/IP connector. • MPC I/O - MPC control/input signals and status
The MPC Interface circuit board powers and controls an output signals are carried in the I/O cables that
should already be connected - See Inputs (J2) and
external MPC module. This external module, (that can
Outputs (J3) in Figure 11-3.
be ordered with a minimum of two probe controls up to
a maximum of 16 probe controls), must be purchased in
addition to a basic generator for a fully functional MPC • MPC INTERFACE - Attach one end of the MPC
system. Interface cable (Dukane # 200-1408-XX) to the MPC
Connections needed for the MPC Interface board and INTERFACE connector on the iQ generator panel -
MPC Interface in Figure 11-3. Connect the other end
those required for the external MPC module are described
of the cable to the MPC INTERFACE connector on
below. the right rear of the MPC module.
J2
C US
UL: 1012:2010
CSA: C22.2 61010-1-12
0 LINE VOLTAGE:
200-240 Vac IEC: 61010-2012
50/60Hz, 10A J9 MPC INTERFACE
-WARNING- J3
POWER LINE OUTLET
ETHERNET J1
MUST BE GROUNDED
DISCONNECT LINE POWER
BEFORE REMOVING COVER J8
PE U.S. PATENTS 7,475,801
J4 U/S
7,819,158 AND 7,225,965
Continued
Page 100
Dukane Manual Part No. 403-588-00
Section 11 - Options
0.25
[6.35] C
(6 PLCS) C/2
MPC1610
MPC1612 18.25 1.75 18.00 2.25
MPC1614 [464 mm] [45 mm] [457.2 mm] [57.2 mm]
MPC1616
Continued
30kHz 41A60R-129
200-615-XX
40kHz 41A40
B A C
Figure 11 - 5 MPC Interface Rear Connectors
Continued
Page 102
Dukane Manual Part No. 403-588-00
Section 11 - Options
Continued
Generator’s MPC
Ready Status Yes
Output deactivates.
Move probes to
the welding
position.
Move probes to part
loading position.
Generator processes
the weld according to
its hardware and
MPC Ready software settings.
No Status Output
active?
Yes
Generator Ready
PLC activates No Status Output
active? Yes
generator’s binary
code inputs to select
active probe.
Page 104
Dukane Manual Part No. 403-588-00
Section 11 - Options
current loop compliance voltage is 6 volts minimum. Figure 11-9 Current Loop Transfer Function Graph
Failure to provide at least 4mA of loop current is sensed as a
fault and will produce minimum amplitude output.
The current loop fault indicator is a bi–color LED. It is green
when the current is between 4 and 20mA and red when the
current is below 2mA.
SYSTEM INPUTS
J2
SYSTEM OUTPUTS
SHIELD
NEG
POS
AGE:
J9
A
ETHERNET J3
J7 U/S
STATUS CONFIGURATION
E-STOP CURRENT LOOP J1
INPUT
PE
J4
Figure 11-10 Generator Rear View - Optional Remote Amplitude Control Module
Continued
LANGUAGE
REGIONAL SETTINGS MENU ONLINE
iQ Amplitude
IMPERIAL 100%
Weld
UNITS
Remote Amplitude
METRIC
Disabled
LANGUAGE
REGIONAL SETTINGS MENU ONLINE
iQ Amplitude 100%
IMPERIAL
Remote Amplitude
METRIC Disabled
Weld
UNITS
LANGUAGE
REGIONAL SETTINGS MENU ONLINE
iQ Amplitude 100%
IMPERIAL
Remote Amplitude
METRIC Enabled
Weld
UNITS
Page 106
Dukane Manual Part No. 403-588-00
Section 11 - Options
DUKANE CORP.
I
ST. CHARLES IL. 60174
MADE IN U.S.A.
J2
C US
UL: 1012:2010 J3
CSA: C22.2 61010-1-12 J9
0 LINE VOLTAGE:
IEC: 61010-2012 ETHERNET J5
J6
200-240 Vac
50/60Hz, 10A
-WARNING-
POWER LINE OUTLET J4 J1
MUST BE GROUNDED
DISCONNECT LINE POWER ABORT BASIC THRUSTER
BEFORE REMOVING COVER
PE U.S. PATENTS 7,475,801 U/S
7,819,158 AND 7,225,965
Figure 11-12 Generator Rear View - Optional Automation Thruster Control Module
1
9
5 1
18 10
9 6 26
19
Figure 11-13 DB-9 Connector with Pin Locations (J6) Figure 11-14 HD-26 Connector with Pin Locations (J5)
Page 108
Dukane Manual Part No. 403-588-00
Section 11 - Options
TM
Control Parameters Available via RS-232
(Time and Energy option)
iQLinQ communication options allow automated systems
1. Set weld method to Time, Energy, or Peak Power. Set
to monitor and change settings in iQ generators. These
associated values in seconds, joules, or watts.
options provide machine builders the ability to integrate
the generator into an electrical cabinet and to use the 2. Set Amplitude, Ramp Up Time, and Ramp Down
Time.
machine’s HMI to program or monitor weld settings.
3. Enable and set Trigger by Power parameters.
All Dukane iQ LS-E generators include the EtherNet/IP
Interface connector, which can be used to set amplitude 4. Enable and set Hold Time.
and monitor power. Using this interface avoids adding 5. Enable and set Afterburst delay and duration.
expensive analog cards into PLC racks. (See Pages 31-32 6. Enable checking for Suspect Parts. Set maximum and
for more information about the EtherNet/IP connector.) minimum values for Time, Power and/or Energy.
iQLinQ also provides a cost effective solution for adding
7. Enable checking for Bad Parts. Set maximum and
the Weld by Energy feature that is only available in the
minimum values for Time, Power and/or Energy.
more advanced iQ generators. In addition to EtherNet/IP,
iQLinQ is also available for PROFIBUS and the RS-232 8. Configure advanced hardware settings including Phase,
Free Run Frequency, Frequency Lock and Hold, and
interface.
Frequency Limits.
iQLinQ solutions are available to provide complete
ladder logic and HMI screens that can be dropped into
Parameters that can be Obtained via RS-232
Allen Bradley (RSLogix 5000) and Siemens (Step 7) PLC
(Time and Energy option)
projects. Contact your local Dukane representative for
more information about the iQLinQ options. 1. All control parameters that are configured via RS-
232.
iQLinQ RS-232 Interface Option 2. Real time data that includes welder state (ultrasound
The RS-232 Interface option allows the iQ generator to active or not), frequency, power, and amplitude.
connect to a PLC’s serial port. Each generator requires a 3. Weld cycle data from previous weld that includes:
dedicated connection to automation, so it is not possible to
• Cycle Count
daisy-chain or bus multiple generators on a single RS-232
connection. • Good, Bad, and Suspect Part information
• Process Limit setting exceeded or not reached if
Control Parameters Available via RS-232 Bad or Suspect Part checking is enabled
(Time [only] option)
• Weld Time
1. Set these parameters: Weld Time, Amplitude, Ramp Up
Time, and Ramp Down Time. • Weld Energy
2. Configure advanced hardware settings including Phase, • Peak Power
Free Run Frequency, Frequency Lock and Hold, and
For information on how to control and/or monitor specific
Frequency Limits.
parameters, iQ Generator RS-232 Communication and
Control documentation is available.
Parameters that can be Obtained via RS-232
(Time [only] option) Signing a non-disclosure agreement is required to obtain
1. All control parameters that are configured via RS- this documentation.
232.
2. Real time data that includes welder state (ultrasound
active or not), frequency, power, and amplitude.
Control Parameters Available via PROFIBUS • Process Limit setting exceeded or not reached if Bad
or Suspect Part checking is enabled
1. Set weld method to Time, Energy, or Peak Power. Set
• Weld Time
associated values in seconds, joules, or watts.
• Weld Energy (Time and Energy option)
2. Set Amplitude, Ramp Up Time, and Ramp Down
Time. • Peak Power
3. Enable and set Trigger by Power parameters. For information on how to control and/or monitor specific
4. Enable and set Hold Time. parameters, iQ Generator PROFIBUS Communication and
Control documentation is available.
5. Enable and set Afterburst delay and duration.
Signing a non-disclosure agreement is required to obtain this
6. Enable checking for Suspect Parts. Set maximum and
documentation.
minimum values for Time, Power and/or Energy.
7. Enable checking for Bad Parts. Set maximum and
minimum values for Time, Power and/or Energy.
8. Configure advanced hardware settings including
Phase, Free Run Frequency, Frequency Lock and
Hold, and Frequency limits.
DUKANE CORP.
ST. CHARLES IL. 60174
I MADE IN U.S.A.
J2
C US
LINE VOLTAGE: UL: 1012:2010
CSA: C22.2 61010-1-12
0
200-240 Vac
J16
50/60Hz, 15A IEC: 61010-2012 BUS ERROR
-WARNING- J3
POWER LINE OUTLET J1
MUST BE GROUNDED PROFIBUS
DISCONNECT LINE POWER
BEFORE REMOVING COVER
PE
U.S. PATENTS 7,475,801
J4 U/S
7,819,158 AND 7,225,965
PROFIBUS
Module
Figure 11-15 Generator Rear View - Optional PROFIBUS Communications Module
Page 110
Dukane Manual Part No. 403-588-00
Section 12 - Contacting Dukane
SECTION 12
Contacting Dukane
Page 112
Dukane Manual Part No. 403-588-00
Section 12 - Contacting Dukane
Contacting Dukane
Identify Equipment
When contacting Dukane about a service–related
problem, be prepared to give the following information:
• Model number, line voltage and serial number
• Alarm/Fault indicators from the display
• Software version (Press INFO. With selection indica-
tors at System Information, press ENTER to get this
data.)
• Problem description and steps taken to resolve it
Many problems can be solved over the telephone, so it is
best to call from a telephone located near the equipment.
Intelligent Assembly
Solutions
Mailing Address: Dukane Ultrasonics
2900 Dukane Drive
St. Charles, IL 60174 USA
E-Mail: ussales@dukane.com
Fax:
Main (630) 797–4949
Website
The website has information about our products,
processes, solutions, and technical data. Downloads are
available for many kinds of literature. This is our main
web address:
www.dukane.com/us/
Page 114
Dukane Manual Part No. 403-588-00
Section 13 - Specifications
SECTION 13
Specifications
Page 116
Dukane Manual Part No. 403-588-00
Section 13 - Specifications
Weights
High Profile Low Profile High Power 3600W High Power 4800W
lb kg lb kg lb kg lb kg
Generator
25 11.3 23 10.4 32 14.5 34 15.4
Only
Generator
+ Packing 30 13.6 28 12.7 37 16.8 39 17.7
Materials
Table 13–I iQ Generator Weights
Operating Environment
Operate the generator within these guidelines:
Temperature: 40°F to 100°F (+4°C to +38°C)
Air Particulates: Keep the equipment dry
Minimize exposure to moisture, dust, dirt, smoke
and mold
Humidity: 5% to 95% Non–condensing @ +5°C to +30°C
Page 118
Dukane Manual Part No. 403-588-00
AC Power Requirements
Page 119
Section 13 - Specifications
Generator
The AC line voltage and current needed depend on whichever generator has been chosen for your system. See the table below.
Overload
Power Input AC Power Requirements North America/ Output Output
Operating Generator
Ratings Nominal AC Volt Japan Voltage Current
Frequency Model Number
@ Maximum RMS Current AC Outlet Rating (Max) (Max)
(Watts)
15kHz 15HB360-2♦-XX-XX 3600 200-240V 50/60 Hz @ 25 Amps 1400 VAC 5A
30 Amps
15kHz 15HB480-2♦-XX-XX 4800 200-240V 50/60 Hz @ 30 Amps (Nominal) (Nominal)
20kHz 20HB120-1♦-XX-XX 1200 **100-120V 50/60 Hz @ 15 Amps
20kHz 20HB120-2♦-XX-XX 1200 200-240V 50/60 Hz @ 8 Amps 700 - 1300 VAC 1.5 - 3 A
15 Amps
20kHz 20HB180-2♦-XX-XX 1800 200-240V 50/60 Hz @ 12 Amps (Nominal) (Nominal)
20kHz 20HB240-2♦-XX-XX 2400 200-240V 50/60 Hz @ 15 Amps
20kHz 20HB360-2♦-XX-XX 3600 200-240V 50/60 Hz @ 25 Amps 1400 VAC 5A
30 Amps
20kHz 20HB480-2♦-XX-XX 4800 200-240V 50/60 Hz @ 30 Amps (Nominal) (Nominal)
30kHz 30HB090-1♦-XX-XX 900 100-120V 50/60 Hz @ 8 Amps
30kHz 30HB090-2♦-XX-XX 900 200-240V 50/60 Hz @ 8 Amps
30kHz 30HB120-1♦-XX-XX 1200 **100-120V 50/60 Hz @ 15 Amps
30kHz 30HB120-2♦-XX-XX 1200 200-240V 50/60 Hz @ 8 Amps
30kHz 30HB180-2♦-XX-XX 1800 200-240V 50/60 Hz @ 12 Amps
700 - 1300 VAC 1.5 - 3 A
40kHz 40HB060-1♦-XX-XX 600 100-120V 50/60 Hz @ 8 Amps 15 Amps
(Nominal) (Nominal)
40kHz 40HB060-2♦-XX-XX 600 200-240V 50/60 Hz @ 5 Amps
40kHz 40HB090-1♦-XX-XX 900 100-120V 50/60 Hz @ 15 Amps
Ultrasonic Pressure
Ultrasonic Pressure
iQ Generator Models - kHz 15 20 30 40 50
Useful Beam 360 degrees
Ultrasonic Pressure @ Operator's Position - dB 125 140 130 130 130
Ultrasonic Pressure 1 m from the Equipment- dB 110 130 110 105 110
NOTE
All measurements taken with Data Physics
Dynamic 4-Channel Signal Analyzer with
calibrated 377C01 Microphone and 426B02
Preamplifier.
Page 120
Dukane Manual Part No. 403-588-00
iQ Probe Generator Model Number Codes
Page 121
Section 13 - Specifications
2 0 H B 2 4 0 2 W R 1
Nominal U/S Frequency Power Level System Process Control
15 = 15kHz 480 = 4800 Watts Probe System Options
20 = 20kHz 360 = 3600 Watts G = LS-E Graphic LCD w/iQLinQ™ EIP (Time
30 = 30kHz 240 = 2400 Watts Only)
40 = 40kHz 180 = 1800 Watts W = LS-E Graphic LCD w/ iQLinQ™ EIP (Time
50 = 50kHz 120 = 1200 Watts and Energy)
090 = 900 Watts
060 = 600 Watts
018 = 180 Watts
Chassis Style - Power Switch Configuration Options Slot #1
HB = Horizontal Bench Chassis - Probe Generators LS-E Probe Series (G and W)
R1 = Remote Amplitude Control Module
R2 = Remote Amplitude Control Module (3600/4800W)
C1 = iQLinQ™ Profibus Interface Module (W Only)
P0 = Automation Thruster Control Module
AC Line Input
2 = 200-240V for 5.25” Tall chassis
1800W and 2400 W only
2 = 200-240V for 3.5” Short chassis
Figure 13- 2
Energy Controller and a Remote Control option board. The system
power cord (if needed) is listed as a separate line item on the sales
order to match the user’s specific AC line power outlet configuration.
iQ Series, Ultrasonic Generator/Power Supply LS-E User’s Manual
IP Rating CAUTION
The iQ generator has an IP (International Protection)
rating from the IEC (International Electrotechnical DO NOT make any modi-
Commission). fications to the generator
or associated cables as
The rating is IP2X, in compliance with finger-safe
the changes may result
industry standards.
in violating one or more
regulations under which
this equipment is manufactured.
Page 122
Dukane Manual Part No. 403-588-00
Section 13 - Specifications
Default Frequency Independent Settings
Amplitude Setting for Weld and Test (Percent) 100% (maximum user adjustment limit)
Output Activation Duration Process Status Maintained (activates until next weld cycle starts)
Cycle Start Input Delay Time Solid State (0.0msec. delay time)
Programmable Status Output #1 Default Assignment OVERTEMP Status (J3 Pin 4 System Output)
Programmable Status Output #2 Default Assignment Hold Status (J3 Pin 5 System Output)
Table 13-V Default Frequency Independent Settings
Continued
Page 124
Dukane Manual Part No. 403-588-00
Appendices
APPENDICES
Page 126
Dukane Manual Part No. 403-588-00
Appendices
Page 128
Dukane Manual Part No. 403-588-00
Appendices
Continued from Previous Page
Page 130
Dukane Manual Part No. 403-588-00
Index
Index
Page 132
Dukane Manual Part No. 403-588-00
Index
G I
Generator 4 Installation
Features 4 Active Seismic Region 15
AC Power Inrush 4 Automation Controlled Probe System 18
Automatic Tuning 4 Before Installation 13
CE Certification 4 Connecting Cables 17
Control Board Option Modules 4 Placement 15
Flow Through Cooling Tunnel 4 Power Cords 17
High Line Voltage Power Supply 4 RFI Grounding 16
ISO 9001 Certification 4 System Outputs Connector 25
Linear Ramp Soft-Start 4 Unpacking 15
Line Voltage Regulation 4 When to Use Lockout / Tagout Devices 13
Load Regulation 4 International Power Grounding 9
Low Line Voltage Power Supply 4 IP (International Protection) Rating 122
Multiple Electronic Overload 4 iQ LinQ 109
Process Limits 4 PROFIBUS Communications Module 110
Process Parameters 4 RS-232 109
Program 4 ISO 9001 Certification 4
Pulse Width Modulation 4
L
TUV Certification 4
No Ultrasound Output 89 Lifting the Equipment 10
Overview 4 Lighted Power Indicator 39
Start-up Sequence 46 LIMITS 58
Testing 83 Linear Ramp Soft-Start 4
Generator Menu Overview 48 List of Figures 127
List of Tables 130
H
Load Regulation 4
Health and Safety 5 Low Line Voltage Power Supply 4
Electrical Safety 8
M
Domestic Power Grounding 9
International Power Grounding 9 Maintenance
General Considerations 7 Front and Rear Panels 93
How to Lift Safely 10 Manual Welding 79
Plastics Health Notice 8 Menus 48
Recommendations 7 Multiple Electronic Overload 4
High Line Voltage Power Supply 4
N
Hot Keys 38
How to Lift Safely 10 Navigation Keys 37
Networking
Network Settings 73
Network Settings 73
Page 134
Dukane Manual Part No. 403-588-00
Index
Continued
S Continued U
System Parameter Settings 123 Ultrasound Output Connector 30
Ultrasonic Pressure 120 User Information 3
Standard Connections 19 Drawings and Tables 3
AC Power Inlet Panel 22 Notes, Cautions and Warnings 3
Start-up Sequence 46 Read the Manual First 3
Status Output Signals 79 Using the INFO Menus 66
Stopping the Ultrasound Output 85 Advanced Settings
Stopping the Weld Cycle 47 Adv Process Control Sub-menu Items 69
System Freq Limits 70 Miscellaneous Sub-menu Items 74
System I/O Panel 22 Network Settings 73
Configuration Port Connector 31 SYSTEM STATUS I/O Sub-menu 71
EtherNet/IP Port Connector 31 ADVANCED SETTINGS 67
System Inputs Connector 22 Using the Menus 48
System Inputs Signal Descriptions 23 Amp
Ultrasound Output Connector 30 Remote Amplitude Board 51
System Operating Mode Keys 36 AMP 49
System Outputs Connector 25 IN CYCLE 65
System Power Output Level 39 LIVE 65
System Status I/O POST-WELD 56
Auto Start Input 72, 74 PRE-WELD 52
Auto Stop Input 72 MPC Module Installed 54
J3 Pin 4 72 Remote Amplitude Board 51
J3 Pin 5 72 SETUPS 60
Output Duration 72 TEST 65
SYSTEM STATUS I/O 71 Using the INFO Menus 66
System Test 84 WELD 55
System Verification Tests 83
W
T
Weld
TEST 65 Weld Cycle
Troubleshooting MAX TIME 55
No Ultrasonic Output 89 WELD 55
Welding Problems 90 Welding Problems 90
TUV Certification 4 When to Use Lockout /
Tagout Devices 13
Page 136
Dukane Manual Part No. 403-588-00
Dukane ISO
ISO CERTIFICATION
Dukane chose to become ISO 9001 certified The ISO 9001 standard establishes a minimum
in order to demonstrate to our customers our requirement for these requirements and starts
continuing commitment to being a quality ven- transitioning the company from a traditional
dor. By passing its audit, Dukane can assure inspection–oriented quality system to one
you that we have in place a well–defined and based on partnership for continuous improve-
systematic approach to quality design, manu- ment. This concept is key in that Dukane no
facturing, delivery and service. This certificate longer focuses on inspection, but on individual
reinforces Dukane's status as a quality vendor processes.
of technology and products.
Dukane's quality management system is based
To achieve ISO 9001 certification, you must on the following three objectives:
prove to one of the quality system registrar 1. Customer oriented quality. The aim is to
groups that you meet three requirements: improve customer satisfaction.
1. Leadership 2. Quality is determined by people. The aim
2. Involvement is to improve the internal organization and
3. Quality in Line Organizations and Quality cooperation between staff members.
System Infrastructure. 3. Quality is a continuous improvement.
The aim is to continuously improve the
internal organization and the competitive
position.
ISO 9001
CERTIFIED
Dukane products are manufactured in ISO
registered facilities.
www.dukane.com/us/sales/intsales.htm