485SD9R Startup

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Product Overview Pinouts

485SD9R DB9 Female DTE


Signal DB9 Pin # RS-232 Connector
RS-485 Side Data A(-) 2 or 8
Data B (+) 3 or 7 Pin 2 - RD 2
Signal Ground 4 or 6
Pin 3 - TD 3
DB9F Pinout
485SD9R RS-485 2-Wire Device Pin 5 - SG 5
5 4 3 2 1
9 8 7 6 Data (A) - Data - Pin 7 - RTS 7
(2 or 8)

Data (B)+ Data + Pin 8 - CTS 8


(3 or 7)
GND
RS-232 Side (4 or 6)
GND Pin 6 - DSR 6

Pin 1 - DCD 1

Pin 4 - DTR 4
485SD9R DB9 Female
1 RS-232 Side RS-485 2-Wire Connector
Connector: DB-9 female.
Pin 2 - Data A(-) 2 Note: TD is also used to power
Signals: Passes through pins 3 (TD) and 2 (RD). the converter
Pins 7 (RTS) and 8 (CTS) are tied together. Pin 8 - Data A(-) 8
Pins 4 (DTR), 6 (DSR), and 1 (CD) are tied
together.
Pin 3 - Data B(+) Note: Control signals are
3 looped back as shown. they
2 RS-485 Side are not used for flow control.
Pin 7 - Data B(+) 7 However, they provide
Connector: DB-9 female. power to the converter. We
recommend connecting all
Signals: 2 wire, half-duplex operation only. Pin 4 - SG 4 control signals.
Automatic control circuit enables driver only when
transmitting. Pin 6 - SG 6
Receiver is disabled when transmitting to prevent
echo back to RS-232 device.
Q uick
Technical Notes Recommended Accessories Start
Guide
Although the 485SD9R uses handshake lines to
9PAMF3
power the converter, no handshaking is required DB9 Male To DB9 Female,
to control the RS-485 driver. The RS-485 driver is
automatically enabled during each spacing state 3 Ft Serial Cable
on the RS-232 side. During the marking or idle http://www.bb-elec.com/Products/Power-
state, the RS-485 driver is disabled and the data Supplies-Accessories/Serial-Cables/DB9-
lines are held in the marking state by the 4.7K to-DB9.aspx
ohm pull-up and
pull-down resistors. 4WSD9OTB
See B+B SmartWorx free RS-422/RS-485 Isolated Universal
Application Note for more information on Converter
termination and DC biasing of an RS-485
http://www.bb-elec.com/Products/
network.
Serial-Connectivity/Serial-Converters/
Isolated-Serial-Converters-and-
No external power is required if two RS-232
Repeaters/4WSD9OTB.aspx
output handshake lines are available. If the
handshake lines are raised and no termination is
used, the power efficiency is greatly increased.
Less than 3mA is required to operate the 485SD9R
485SD9R plus the load current.
Fast Easy Answers... Port-Powered RS-232 to RS-485 Converter

You can use your


smart phone to access complete
documentation
on our website. Simply
scan the code to the right.

First Things First...


Before you begin, be sure you
have the following:
485SD9R

Additional items required but not included:


Serial Cables

1-888-948-2248 | Europe: +353 91 792444

www.bb-smartworx.com

707 Dayton Road | PO Box 1040 | Ottawa, IL 61350


Phone: 815-433-5100 | Fax: 815-433-5109

Document number – pnxxx_485SD9R_R0_1714qsg © 2015 B+B SmartWorx Fast and easy on the web: www.bb-smartworx.com

You might also like