Warrior EXTREME

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

NO MORE COLD BLOOD & FLUIDS

Warrior EXTREME
(Q1210S0000)

Top performance yet genuinely portable


blood and IV fluid warmer for mid- and
long-haul critical care transports

:
June 2019 | Version 2

TREME:

Key Benefits:
brid: • Simple to Operate: One button operation; simple setup
• Portable: Can fit small transport platforms such as Bell
407
• Immediate Warming: Warm fluids in less than 11 seconds
• At Any Input Temperature: Even at 4˚C / 39˚F fluid
C: input temperature
• Even At High Flow Rates: Up to 200ml/min for the full
warming range (4˚C-38˚C / 39.2˚F-100.4˚F)
• Highly Efficient Technology: 3-5 liters of warmed
fluids with a single battery
• Highest Regulatory Envelope: IEC 60601-1-12 and IEC
and visual notifications; aluminum free (heat exchanger
60601-1-2:2014 (EMC standard 4th edition) certified; MIL-
using medical grade stainless steel)
STD 461G RE102 & RS103 compliant
• Field Proven Technology: In commercial use since early
• Mountable: To pole, rail or stretcher
2014 with hundreds of end users
• Communicative: Built-in display
• Affordable Consumables: Cost effective consumable
• No Calibration: No need for periodic calibration design
• Practically Zero Maintenance: 5 years between service • Multipurpose Consumables: The same consumable
cycles fits all protocols
• Patent-Protected Technology: Patented warming • Unique Continuum of Emergency Care Proposition:
technology & controls Same consumable can be used across the entire
• Safe Technology: Gradual warming; real-time continuum of emergency care, simplifying patient
temperature sensing with auto-adjustments and audio handoff between emergency settings and reducing costs

For more information: info@qinflow.com


11 Ha'avoda st. Rosh Ha'ayin 4801761 Israel | 2305 Coit Dr., Suite A, Plano, TX 75075 USA | www.qinflow.com
lite:

NO MORE COLD BLOOD & FLUIDS

Warrior EXTREME EXTREME:

(Q1210S0000)

Core Components:
Performance: Hybrid:
EXTREME Base Unit (QPORT110012)
Set-Point Temperature 38°C (±2°C) / 100.4°F (±3.6°F) Hosts the control module and user indications
Warming Time Up to 11 seconds (audio, visual). Connects with the battery and
the Disposable Unit (note: Standard Base Unit
Minimum Delivery Rate KVO or 2 ml/min configuration available as well; contact your
Maximum Delivery Rate at Up to 200 ml/min QinFlow representative for details)
4°C/39.2°F Input [1] [2] AC:
Enhanced Battery (QPORT1180)
Maximum Delivery Rate Up to 290 ml/min Rechargeable, Li-ion, 22.2V (nominal), 4,600mAh
at 20°C/68°F Input [1] [2]
Battery Capacity 3 liters
at 4°C/39.2°F Input Disposable Unit Options:
Battery Capacity 5 liters Standard Disposable Unit (QPORT1200)
at 20°C/68°F Input Standard sterile disposable unit; hosts the
warming apparatus
Physical Characteristics:
Compact Disposable Unit (QPORT0500)
Dimension (W x L x H) 7.8 x 15.6 x 23.2 cm Compact sterile disposable unit for space
3.07” x 6.14” x 9.13” constrained
Weight 1,720 g / 3.79 lb

Electrical Characteristics: Charging Components:


Battery Characteristics Rechargeable, Li-ion, 22.2VDC (nominal), Charger (FY-17036-ADT or MASCOT9940Li)
4,600mAh
Adapter (QPORT1330)
Battery Charging Input Voltage 100–240 VAC | 50–60 Hz | Max 2.0 A | 12/24V

Target Regulatory Envelope: Accessories:


Certifications CE, FDA & Health Canada Mounting (QPORT1010)
Mounting option to pole, rail or stretcher
IEC • IEC 60601-1
• IEC 60601-1-2:2014 (EMC standard 4th edition) Extension Cable (QIF-CBL00019)
• IEC 60601-1-12 To extend the connection between the base unit
Compliance • EN1789 and the disposable unit
• MIL-STD 461G RE102 & RS103
Soft Carrying Bag (QPORT1410)
Environmental Specifications: Hard Carrying Case (QPORT1400)
Storage Conditions -30⁰C to 70⁰C (-22⁰F to 158⁰F) [3]

Operating Conditions -5°C to 40°C (23⁰F to 104⁰F)


Transient operating conditions -20°C to 50°C (-4°F to 122°F) & 90% RH
Atmospheric Pressure /Altitude 549 to 1,060 hPa / -400 to 4,572 meter
(-1,312 to 15,000 ft) [4]
Ingress Protection (IP) IP56

[1] Using standard IV kit and a 14G Venflon; blood products’ flow rate may differ to their viscosity.
[2] This document is based on EU-approved spec. For the USA-cleared version, please refer to the IFU or to your QinFlow representative.
[3] Under EN1789:2007 +A2:2014.
[4] In compliance with IEC60601-1-11:2010 section 4.2.2c.

Note: the information provided in the Instructions ˚C = degree in Celsius cm = centimeter hPa = hecto Pascal (100 Pascal) lb = Libra (Pound)
For Use (IFU) shall govern in case of conflict .This ˚F = degree in Fahrenheit Standard DU = Disposable Unit IEC = International Electrotechnical Commission MIL-STD = Military Standard
document is adjusted to CE approvals; for exact “ = Inch EN = European Norms IFU = Instructions for Use ml/min = milliliter per minute
specifications of the USA-cleared version, please AC = Alternate Current FDA = Federal Drug Administration IP = Ingress Protection rating RH = Relative Humidity
refer to the relevant IFU or contact your QinFlow BU = Base Unit Ft = Feet IV = Intravenous W x L x H = Width x Length x Height
representative. CDU = Compact Disposable Unit g = gram KVO = Keep Vein Open

For more information: info@qinflow.com


11 Ha'avoda st. Rosh Ha'ayin 4801761 Israel | 2305 Coit Dr., Suite A, Plano, TX 75075 USA | www.qinflow.com