21 - ENG - 102715 Practical 03
21 - ENG - 102715 Practical 03
INSTALLATION
2
Total charge is = 227.65*2 + 290 + 804.75 + 1856.00 + 13230.00
= 16636.05
N L
14. 5 A and 15 A
15. 13 A
3
Practical Works
Part 3 – Domestic Electrical installation
5. a.
Components Corresponding Components Corresponding
label in figure 1 label in figure 1
Part 4
1. 13A socket and plug outlet or type G sockets.
2. Energy meter, MCB, RCCB, Single pole MCBs in distribution board, Switch,
Sockets, Electronic appliances and bulbs.
3. Rated voltage: 230 V, Rated current 5 - 40 A
No if cannot use to measure the reactive power consumption.
4. When the excess current flow through the MCB, bimetallic strip will heat and bend
and release a latch. That latch will turn off the MCB.
Swich is use to turn on and off the circuit and hasn’t any mechanism to react to the
overflow current.
5. Advantage: It is very cheaper than the MCB.
Disadvantage: Not much sensitive than the MCB.
6. There is a permanent magnet with winded coil around it in the RCD. When the fault
signal received due to the earthing, coil will use to generate magnetic field that can
reject the field of permanent magnet. When the magnetic field disabled, RCD will
trip.
4
7. Because it can control and supply the amperage to each sub systems. Easy to ensure
the security separately against the short circuits.
8. Circuit shorts: MCB
Earthing: RCB
9.
RING TYPE
E
L
N
RADIAL TYPE
5
10.
It is better to supply the power using separate MCB for the ac unit. Suitable MCB is
15A one.
Indoor Unit
MCB 15A
Outdoor Unit
L N E