EMERGENCY MANUAL GENERAL FORM

Card No Emcy-003B Version 01 2021-09-14 Page 1 of 2


Tactical firefighting plan: Fire in GALLEY
Safety officer shall use the applicable tactical firefighting plan.
Caution: All tactical firefighting plans shall be available and ready to use in in each meeting point (such as: Bridge, Fire
stations, ECR…).

DECK “B”
1 - 3

ACCOMMODATION

CLOSE FLAPS
1. C-deck port E-5 Manual closing
2. C-deck starboard E-6 Manual closing
3. Galley fire damper port Manual closing
4. Galley fire damper starboard Manual closing
5. Galley fire damper Manual closing
6. Remote control starboard Manual closing
7. Remote control alleyway Manual closing

STOP VENTILATION
1 5 1. Stop for ventilation Alleyway

1
FIRE FIGHTING SQUAD HOSES
Fire control station
Number of hoses 1 length
7 2

FIRE SUPPORT SQUAD FIRE HOSES


Machinery fire station
4 Hose split NO
Fire fighting 2 lengths
Outside cooling 3 lengths

CUT OFF POWER


6 Deck B
1. Emergency stop for galley ES-5

Engine control room

LOCAL FIRE FIGHTING SYSTEM


1. CO2 release Alleyway
2. Wet chemical – deep fat fryer Galley

1
EMERGENCY MANUAL GENERAL FORM
Card No Emcy-003B Version 01 2021-09-14 Page 2 of 2
Tactical firefighting plan: Fire in GALLEY

DECK C: GALLEY STORE UPPER DECK – C deck: CREW CABINS 2, 3,4,5


RISK CLASS A (plastic, wood …)

FORWARD: OUTSIDE STARBOARD: OFFICER’S PANTRY


RISK No specific risk identified RIS No specific risk identified
K

GALLEY

PORT: CREW MESSROOM AFT: ALLEYWAY


RISK CLASS A (plastic, carton, wood …) RISK CHIMNEY EFFECT

LOWER DECK – A deck: GYMNASIUM, DRY STORE


RISK CLASS A (plastic, carton, wood …)

Completed