Totally Integrated

Automation Portal

Main [OB1]
Main Properties
General
Name Main Number 1 Type OB
Language LAD Numbering Automatic
Information
Title DEN GIAO THONG Author Comment
Family Version 0.1 User-defined
ID

Name Data type Default value Comment


Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Network 1: SETTING THOI GIAN THUC

RD_SYS_T T_CONV
DTL DTL TO Time_Of_Day
EN ENO EN ENO
%MW10 "readtime". "readtime".
RET_VAL "Tag_1" readtime IN OUT daytime

"readtime".
OUT readtime

Network 2: CHE DO BAN DEM


Totally Integrated
Automation Portal

"readtime". "readtime". "readtime". %M6.0


readtime.MONTH readtime.MONTH daytime
"CD DEM"
>= <= >=
USInt USInt Time_Of_Day
1 6 TOD#22:00:00

"readtime".
daytime
<=
Time_Of_Day
TOD#5:30:00

"readtime". "readtime". "readtime".


readtime.MONTH readtime.MONTH daytime
>= <= >=
USInt USInt Time_Of_Day
7 12 TOD#22:00:00

"readtime".
daytime
<=
Time_Of_Day
TOD#6:00:00

Network 3: KHOI KHOI DONG

%M5.0 %M5.1 %M6.2


"START" "STOP" "SYSTEM"

%M6.2
"SYSTEM"

Network 4: THOI GIAN BINH THUONG

%DB2
"IEC_Timer_0_DB"
%M6.2 %M6.0 "IEC_Timer_0_ TON
"SYSTEM" "CD DEM" DB".Q Time
IN Q
T#130S PT %MD10
ET "Tag_2"

Network 5: THANG LUONG 1


Totally Integrated
Automation Portal

%M6.2 %M6.0 "IEC_Timer_0_ %Q0.0


DB".ET
"SYSTEM" "CD DEM" "X1"
<=
Time
T#40S

"IEC_Timer_0_ "IEC_Timer_0_ %M0.0


DB".ET DB".ET
"vang1(ngay)"
> <=
Time Time
T#40S T#45S

"IEC_Timer_0_ "IEC_Timer_0_
%Q0.2
DB".ET DB".ET
"Đ1"
> <=
Time Time
T#45S T#130S

Network 6: RE LUONG 1

"IEC_Timer_0_ "IEC_Timer_0_
%M6.2 %M6.0 %Q0.3
DB".ET DB".ET
"SYSTEM" "CD DEM" "TX1"
> <=
Time Time
T#40S T#60S

"IEC_Timer_0_ "IEC_Timer_0_ %M0.1


DB".ET DB".ET
"tr.vang(ngay)"
> <=
Time Time
T#60S T#65S

"IEC_Timer_0_
%Q0.5
DB".ET
"TĐ1"
<=
Time
T#40S

"IEC_Timer_0_ "IEC_Timer_0_
DB".ET DB".ET
> <=
Time Time
T#65S T#130S

Network 7: che do vang luong 1 ( ngay va dem)


Totally Integrated
Automation Portal

%M0.0 %Q0.1
"vang1(ngay)" "V1"

%M1.0
"vang1(dem)"

%M0.1 %Q0.4
"tr.vang(ngay)" "TV1"

%M1.0
"vang1(dem)"

Network 8: THANG LUONG 2

%M6.2 %M6.0 "IEC_Timer_0_ %Q1.2


DB".ET
"SYSTEM" "CD DEM" "Đ2"
<=
Time
T#60S

"IEC_Timer_0_ "IEC_Timer_0_
DB".ET DB".ET
> <=
Time Time
T#105S T#130S

"IEC_Timer_0_ "IEC_Timer_0_
%Q1.0
DB".ET DB".ET
"X2"
> <=
Time Time
T#60S T#100S

"IEC_Timer_0_ "IEC_Timer_0_ %M0.2


DB".ET DB".ET
"vang2(ngay)"
> <=
Time Time
T#100S T#105S

Network 9: RE LUONG 2
Totally Integrated
Automation Portal

%M6.2 %M6.0 "IEC_Timer_0_ %Q1.5


DB".ET
"SYSTEM" "CD DEM" "TĐ2"
<=
Time
T#100S

"IEC_Timer_0_ "IEC_Timer_0_
DB".ET DB".ET
> <=
Time Time
T#125S T#130S

"IEC_Timer_0_ "IEC_Timer_0_
%Q1.3
DB".ET DB".ET
"TX2"
> <=
Time Time
T#100S T#120S

"IEC_Timer_0_ "IEC_Timer_0_ %M0.3


DB".ET DB".ET
"tr.vang2(ngay)"
> <=
Time Time
T#120S T#125S

Network 10: che do vang luong 2 ( ngay, dem)

%M0.2 %Q1.1
"vang2(ngay)" "V2"

%M1.2
"vang2(dem)"

%M0.3 %Q1.4
"tr.vang2(ngay)" "TV2"

%M1.3
"tr.vang2(dem)"

Network 11: SETTING CHE DO DEM

%DB3
"IEC_Timer_0_
DB_1"

%M6.2 %M6.0 "IEC_Timer_0_ TP


"SYSTEM" "CD DEM" DB_1".Q Time
IN Q
T#3S PT %MD0
ET "DEM"
Totally Integrated
Automation Portal

Network 12: CHE DO DEM

"IEC_Timer_0_
%M6.2 %M6.0 %M1.0
DB_1".ET
"SYSTEM" "CD DEM" "vang1(dem)"
<=
Time
T#1S_500MS
%M1.1
"tr.vang1(dem)"

%M1.2
"vang2(dem)"

%M1.3
"tr.vang2(dem)"

You might also like