TURKISH STANDARD
TS EN 13230-3
Ocak 2004
ICS 45.080
Ön söz
– Bu standard, Türk Standardları Enstitüsü tarafından ilgili Avrupa standardı esas alınarak Türk Standardı
olarak kabul edilmiştir.
EUROPEAN STANDARD EN 13230-3
NORME EUROPÉENNE
EUROPÄISCHE NORM December 2002
ICS 45.080
English version
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
© 2002 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13230-3:2002 E
worldwide for CEN national Members.
EN 13230-3:2002 (E)
Contents Page
Foreword .......................................................................................................................................................4
Introduction...................................................................................................................................................5
1 Scope ................................................................................................................................................5
2 Normative references .......................................................................................................................5
3 Definitions.........................................................................................................................................5
4 Product testing .................................................................................................................................5
4.1 Test arrangements ...........................................................................................................................5
4.1.1 Symbols ............................................................................................................................................6
4.1.2 Rail seat section ...............................................................................................................................7
4.2 Test procedures ...............................................................................................................................9
4.2.1 Test loads .........................................................................................................................................9
4.2.2 Static test........................................................................................................................................10
4.2.3 Dynamic test...................................................................................................................................13
4.3 Acceptance criteria ........................................................................................................................15
4.3.1 Static test........................................................................................................................................15
4.3.2 Dynamic test...................................................................................................................................15
4.3.3 Value of coefficients.......................................................................................................................15
4.4 Design approval tests ....................................................................................................................15
4.4.1 Bending moment evaluation ..........................................................................................................15
4.4.2 Concrete .........................................................................................................................................16
4.4.3 Product inspection .........................................................................................................................16
4.4.4 Fastening system ...........................................................................................................................16
4.5 Routine tests ..................................................................................................................................16
4.5.1 Static rail seat positive load test....................................................................................................16
4.5.2 Concrete .........................................................................................................................................16
5 Steel connecting bar ......................................................................................................................16
5.1 General............................................................................................................................................16
5.2 Steel ................................................................................................................................................16
5.2.1 Chemical composition ...................................................................................................................16
5.2.2 Mechanical properties....................................................................................................................17
5.3 Geometry ........................................................................................................................................17
5.4 Appearance of the steel connecting bar .......................................................................................17
6 Design criteria for incorporating the steel connecting bar...........................................................18
6.1 Length of the connecting bar.........................................................................................................18
6.2 Orientation of the connecting bar..................................................................................................18
6.3 Position of the connecting bar ......................................................................................................18
7 Manufacturing.................................................................................................................................18
7.1 Manufacturing rules .......................................................................................................................18
7.2 Other manufacturing rules.............................................................................................................19
Annex A (normative) Steel connecting bar defects..................................................................................20
A.1 Surface burn ...................................................................................................................................20
A.2 Tear at the end................................................................................................................................21
A.3 Unclean cut.....................................................................................................................................21
A.4 Seam ...............................................................................................................................................22
A.5 Split.................................................................................................................................................23
A.6 Deformation of ends.......................................................................................................................23
A.7 Scale ...............................................................................................................................................24
2
EN 13230-3:2002 (E)
3
EN 13230-3:2002 (E)
Foreword
This document EN 13230-3:2002 has been prepared by Technical Committee CEN/TC 256 “Railway
applications”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by June 2003, and conflicting national standards shall be withdrawn at
the latest by June 2003.
This European Standard is one of the series EN 13230 "Railway applications - Track Concrete sleepers
and bearers" which consists of the following parts:
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark,
Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,
Spain, Sweden, Switzerland and the United Kingdom.
4
EN 13230-3:2002 (E)
Introduction
This part of this European Standard defines the specific requirements relating to twin-block reinforced
sleepers.
These are additional requirements to EN 13230-1 and are necessary to have a complete standard dealing
with twin-block reinforced sleepers.
1 Scope
This part of this European Standard defines technical criteria and control procedures relating to the design
and manufacture of twin-block reinforced concrete sleepers.
2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other publications.
These normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to
this European Standard only when incorporated in it by amendment or revision. For undated references the
latest edition of the publication referred to applies (including amendments).
EN 10002-1, Metallic materials - Tensile testing – Part 1: Method of test at ambient temperature
EN 13230-1:2002, Railway applications - Track – Concrete sleepers and bearers – Part 1: General
requirements.
EN ISO 6506-1, Metallic materials - Brinell hardness test. Part 1:Test method (ISO 6506-1:1999)
3 Definitions
For the purpose of this standard, the following definitions apply.
4 Product testing
The test arrangements for the rail seat section tests are defined in this clause.
5
EN 13230-3:2002 (E)
4.1.1 Symbols
Fro initial reference test load for the rail seat section, in kN ;
Fron negative initial reference test load at rail seat section, in kN; Fron = ½ Fro ;
Frr test load which produces first crack formation at the bottom of the rail seat section, in kN ;
Frrn negative test load which produces first crack formation at the top of rail seat, in kN ;
Fr0,05 test load for which a crack width of 0,05 mm at the bottom of the rail seat section persists
after removal of the load, in kN ;
Fr0,05n test load for which a crack width of 0,05 mm at the top of rail seat section persists after
removal of the load, in kN ;
Fr0,5 test load for which a crack width of 0,5 mm at the bottom of the rail seat section persists
after removal of the load, in kN ;
FrB test load at the rail seat section which cannot be increased, in kN ;
FrBn test load on the top of rail seat section which cannot be increased, in kN ;
Fru lower test load for the rail seat section dynamic test Fru = 50 kN;
Lp design distance between the centre line of the rail seat to the edge of the sleeper at the
bottom
Lr design distance between the articulated support centre lines for the test arrangement at the
rail seat section.
6
EN 13230-3:2002 (E)
The arrangement for the rail seat positive load test is shown in Figure 1.
Key
1 Rigid support
2 Articulated support (see annex B for details)
3 Resilient pad (see annex B for details)
4 Reinforced concrete block
5 Standard rail pad as defined by the purchaser
6 Tapered packing (see annex B for details)
7 Lateral stop
Figure 1 — Test arrangement at the rail seat section (positive bending moment)
7
EN 13230-3:2002 (E)
The test arrangement for the rail seat negative load test is shown in figure 2.
Key
1 Rigid support
2 Articulated support (see annex B for details)
3 Resilient pad (see annex B for details)
4 Reinforced concrete block
5 Special tapered packing
6 Special tapered packing
Figure 2 — Test arrangement at the rail seat section (negative bending moment)
Lp in m Lr in m
8
EN 13230-3:2002 (E)
Fro is calculated from the geometry given in Figure 1 and values from Table 2, using the following equation:.
4Md r
Fro = in kN.
L r − 0,1
9
EN 13230-3:2002 (E)
The static test procedure at the rail seat section for design approval and routine tests is shown in Figures 3.1,
3.2 and 4.
Key
1 Load
2 Time
3 Crack checking
A Required part of test
B Optional part of test
Figure 3.1 — Static test procedure at the rail seat section for positive design approval test
10
EN 13230-3:2002 (E)
Key
1 Load
2 Time
A Required part of test
B Optional part of test
Figure 3.2 — Static test procedure at the rail seat section for positive routine test
Loading in the routine test may be continued to first crack to determine Frr and provide information on the
margin between Fr0 and Frr. This is not part of the pass/fail criteria.
11
EN 13230-3:2002 (E)
Key
1 Load
2 Time
3 Crack checking
A Required part of test
B Optional part of test
Figure 4 — Static test procedure at the rail seat section for negative design approval test
12
EN 13230-3:2002 (E)
The dynamic test procedure at the rail seat section is shown in Figure 5.
The test is carried out on only one block after cutting the steel connecting bar.
Key
1 Load
2 Time
3 5000 load cycles
4 Maximum time for examination 5 minutes
5 Frequency (f) between 2 Hz and 5 Hz
Figure 5a
13
EN 13230-3:2002 (E)
Key
1 Load
2 Time
Note: typical cycle
Figure 5b
14
EN 13230-3:2002 (E)
The tests are managed according to the rules of EN 13230-1. The crack width is measured following the rules
of EN 13230-1:2002 – 7.2.
The acceptance criteria for the static tests at the rail seat section are as follows:
The acceptance criteria for the dynamic test at the rail seat section are as follows:
FrB > k2d x Fro or (according to the requirements of the purchaser) Fr0,5 > k2d x Fro.
The design approval tests to be carried out on the sleeper and concrete comprise the following tests:
each concrete sleeper block shall be used for one test only.
These tests are carried out in accordance with the test arrangements shown in Figures 1 and 2 and the test
procedures in 4.2.
a) static tests
both rail seat sections on 3 sleepers for the positive bending moment;
both rail seat sections on 3 sleepers for the negative bending moment (optional test carried out at the
request of the purchaser).
b) dynamic test
15
EN 13230-3:2002 (E)
4.4.2 Concrete
Product inspection shall be carried out on all sleepers required for design approval tests including dimensions
and tolerances in accordance with EN 13230-1:2002 - Table 1 and the surface finish of the sleeper in
accordance with EN 13230-1:2002 - 6.3.
The tests shall be carried out in accordance with EN 13230-1 or as required by the purchaser.
The routine tests are carried out in order to find any variation in the quality of the concrete sleeper leading to
an unacceptable quality level.
The number of samples and rates of tests are given in the quality plan for the manufacturing unit.
The routine tests to be carried out on the product and concrete are defined in this standard or another
European Standard.
This test is carried out in accordance with the test arrangement shown in Figure 1 and the test procedures
shown in Figure 3.2.
4.5.2 Concrete
5.1 General
This clause specifies the properties and the quality control requirements for the hot-rolled steel connecting bar
for twin-block reinforced sleepers.
5.2 Steel
The chemical composition of the steel shall be within the following limits:
0,28 ≤ C ≤ 0,80 %
0,45 ≤ Mn ≤ 1,40 %
P ≤ 0,08 %
16
EN 13230-3:2002 (E)
S ≤ 0,08 %
Si ≤0 ,50 %
The mechanical properties (conventional yield strength at 0,2 % tensile strength, percentage elongation at
fracture) shall be maintained within the following limits:
The Brinell hardness (HBW) shall be 160 ≤ HBW ≤ 300 when tested according to EN ISO 6506-1.
5.3 Geometry
The dimensions, cross-section, minimum inertia (vertical and horizontal) and shape shall be agreed by the
purchaser.
When determining dimensions, shape and cross-section, the following criteria shall be taken into account:
avoidance of any excessive negative moment in the steel connecting bar due to the bearing of its centre
part on the ballast;
The acceptance criteria of the steel connecting bar are defined in annex A.
17
EN 13230-3:2002 (E)
The connecting bar length Lcb shall be at least greater than the distance L1 (EN 13230-1:2002 - Figure 2)
unless approved by the purchaser.
If the connecting bar is not protected against corrosion, the orientation and shape shall avoid retention of
water.
For handling purposes, the minimum distance "e" (Figure 6) shall be at least 40 mm.
7 Manufacturing
Before starting production, the manufacturer shall complete a production file for manufacturing data which
shall be submitted in confidence to the purchaser and shall include the following:
characteristic compressive and tensile strength of concrete samples after 7 days and after 28 days;
18
EN 13230-3:2002 (E)
The sample sleepers submitted for design approval tests shall comply with the manufacturing data.
The manufacturing shall ensure a tolerance of ± 5 mm in all directions on the positioning of reinforcement
grids with regard to the design position.
Welding to a connecting bar is not allowed unless the welding procedures, including controlled heating and
cooling of the whole section of the connecting bar, have been approved by the purchaser.
19
EN 13230-3:2002 (E)
Annex A
(normative)
A surface burn is represented by localized small cracks on the edges of the section. It is caused by accidental
overheating of the metal.
A surface burn is accepted if its depth does not exceed 3 mm over a maximum length of 500 mm at each end
which is embedded in the concrete.
20
EN 13230-3:2002 (E)
A tear at the end results from shearing stresses (incorrect entry, loose or worn shear blades)
A tear at the end is accepted if its depth does not exceed 20 mm and it is not present on more than 5 % of the
bars in the same batch.
This kind of cut is accepted under the same conditions as a tear at the end (A.2).
21
EN 13230-3:2002 (E)
A.4 Seam
A seam caused during rolling is a longitudinal crack which has the appearance of a line parallel to the edge of
the bar.
A seam is accepted if it appears only on the external faces of the bar and if its dimension E is greater or equal
to the minimum tolerance on thickness and:
22
EN 13230-3:2002 (E)
A.5 Split
A split at the ends of the bars can be accepted if its length does not exceed 500 mm at each end of the bar
and if its depth is less than 5 mm.
Deformation of the ends of the bar is accepted if over a length of 500 mm at each end (the part embedded in
the concrete), the deformation "d" does not exceed 5 mm over a length "l " less than 100 mm.
23
EN 13230-3:2002 (E)
A.7 Scale
Except for the part embedded in concrete, scale shall be removed by grinding and its depth shall not exceed
0,5 mm.
24
EN 13230-3:2002 (E)
Annex B
(normative)
Dimensions in millimetres
Key
1 Minimum length = bottom width of the concrete sleeper at the rail seat + 20 mm
2 High pressure lubricant
Material: steel: minimum Brinell hardness: HBW > 240
General tolerances: ± 0,1 mm
25
EN 13230-3:2002 (E)
Dimensions in millimetres
Key
1 Minimum length = bottom width of the concrete sleeper at the rail seat + 20 mm
Material: elastomer
Static stiffness (C) measured between 0,3 MPa and 2 MPa : 1 ≤ C ≤ 4 N/mm
3
26
EN 13230-3:2002 (E)
Dimensions in millimetres
Key
27
EN 13230-3:2002 (E)
Bibliography
28