Professional Documents
Culture Documents
Hunter Fan Manual
Hunter Fan Manual
1326
PA G E
PA G E
PA G E
PA G E
We are proud of our work and
appreciate the opportunity to Downrod Wiring Canopy Blades
supply you with the best ceiling fan
available anywhere in the world.
PA G E
PA G E
PA G E
PA G E
Save your receipt for proof of purchase.
Operation,
Switch Housing Light Kit Remote Control Maintenance & Cleaning Troubleshooting
? ?
14 15 17 18 ? 20
PA G E
PA G E
PA G E
PA G E
PA G E
1
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
What to Expect with Your Installation www.HunterFan.com 1.888.830.1326
3
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
34O CEILING
OPTION 1
If you have a flat ceiling:
Hang your fan by a standard downrod (included). Standard Support Support
WALL
OPTION 2
If you have an angled ceiling:
Ceiling
1. You will need a longer downrod (sold separately). Outlet Box
2. If your ceiling angle is greater than 34°, you will Angled (required)
Mounting Standard Ceiling
also need an Angled Mounting Kit (sold separately). Angled
Mounting Outlet Box
Style (required) Mounting
Style
Use the three steps below to determine if your ceiling angle is greater than 34°
1 2 3
34°
Guide Touches Guide Touches Wall Use Standard Mounting Use Angled Mounting
BOTH Ceiling & Wall but NOT Ceiling or Low-Profile Mounting to hang the fan from a
You need ONLY You need BOTH to hang the fan from a flat ceiling. vaulted or angled ceiling.
1 2
ON ON
a Longer a Longer
Downrod Downrod &
I
an Angled
SITUAT
SITUAT
4
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Ceiling Bracket www.HunterFan.com 1.888.830.1326
r
owe
rnP
Tu
OFF
For angled ceilings, point
opening toward peak.
Make sure all four bumpers are If you are unable to do this,
still attached. call Technical Support at To avoid possible electrical shock, before
1-888-830-1326. installing your fan, disconnect the power by
Refer to warning w.1 on pg. 2 turning off the circuit breakers to the outlet
box associated with the wall switch location.
5
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Downrod www.HunterFan.com 1.888.830.1326
Option 1
Standard
Downrod skip to next page
for ceilings 8-10’ high
Option 3
Longer Steps 1-5 to remove standard downrod pipe
Downrod
1 2 3 4 5
(pre-assembled)
for angled
ceilings or
ceilings 10’ or
Included
higher
Option 2
Shorter
Slide
Slide
Downrod
for fans installed
close to ceiling
Sold Separately
Included
10 9 8 7 6
Steps 6-10 to reassemble with new pipe
6
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Downrod (continued) www.HunterFan.com 1.888.830.1326
Hanger
Ball
KEEP!
KEEP
!
Adapter
Cover
Slide the adapter cover onto the downrod Remove the pre-installed setscrew so that Hand tighten the downrod (at
until it rests against the hanger ball. the downrod can be inserted. least 4-5 full turns) until it stops.
CUT
STRIP
3/8”
&
(not to scale)
8”
The wires can be cut, but leave at least 8” Tighten the setscrew with pliers. Lower the adapter cover until it rests
extending from the top of the downrod. DO NOT HAND TIGHTEN. flush against the motor housing.
8” 3/8”
If the setscrew is not tightened
securely, the fan may fall.
8
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Downrod (continued) www.HunterFan.com 1.888.830.1326
Put the wires and downrod through the DO NOT PICK THE FAN UP BY THE
canopy. Let the canopy sit loosely on top CANOPY OR WIRES. Place the downrod
of the fan. ball into the slot in the ceiling bracket.
9
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Wiring Note: To connect the wires, hold
www.HunterFan.com 1.888.830.1326
stripe (grounding)
green/yellow
from the hardware bag:
Connect the 3 grounding wires OM FAN
FR
Receiver (green, green/yellow stripe, or bare
copper) coming from the ceiling,
downrod, and ceiling bracket. green/yellow stripe
stripe
green/yellow
Place the receiver on top of the downrod
assembly as shown.
T
O
FR
KE
M
Tip: If you have difficulty fitting the receiver CEIL AC
ING BR
into place, make sure you have cut the excess
wires from the fan. See page 8 for more details.
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
Refer to CAUTION c.1 on pg. 2 the outlet box and the ungrounded wires on the other side of the outlet box.
10
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Wiring (continued) Note: If you have a dual switch,
www.HunterFan.com 1.888.830.1326
Using the orange wire connectors Using the orange wire connectors
yellow
blue
(ungrounded)
black
white (grounded)
from the remote control hardware bag: from the hardware bag:
• Connect the yellow wire from • Connect the black (ungrounded) OM FAN
FR
the receiver to the black wire wire from the ceiling to the black
from the fan. wire from the receiver.
white
• Connect the blue wire from the • Connect the white (grounded)
receiver to the blue wire (or wire from the ceiling to both the
possibly black with white stripe white wire from the receiver and
black
blue
black
white
wire) from the fan. the white wire from the fan.
FR
FRO OM ER
M FA N RECEIV
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
Refer to CAUTION c.1 on pg. 2 the outlet box and the ungrounded wires on the other side of the outlet box.
11
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Canopy www.HunterFan.com 1.888.830.1326
Screw
Holes
Position the canopy so that, when Lift the canopy into place so that Insert the two canopy screws
lifted into place, the canopy fits into the screw holes are aligned. found in the hardware bag.
the hanging bracket as shown.
13
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Switch Housing www.HunterFan.com 1.888.830.1326
Partially install two light kit assembly Feed the 9-pin plug connector coming from Align the keyhole slots in the top of
screws, found in the hardware bag, the bottom of the motor housing through the light kit assembly with the partially
halfway into the motor housing as the center hole in the light kit assembly. installed assembly screws. Wrap the
shown. It does not matter which two Connect it to the plug connector found keyhole slots around the screws and
screw holes you choose. in the switch housing area of the light kit twist counterclockwise.
assembly. Make sure to line up the colored
markings on the connectors. Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing fixture falling.
14
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Light Kit www.HunterFan.com 1.888.830.1326
Insert a third light kit assembly screw, Carefully push all switch housing
found in the hardware bag, into place components into the switch housing,
and tighten all three screws securely. then install the switch housing plate
using two light kit assembly screws,
found in the hardware bag.
Tab
Notch CONGRA
Bulb
YOU’RETULATIONS!
DONE!
Install a light bulb in each socket. Position the notches in the outer rim of
When necessary, replace with bulbs of the globe so they line up with the tabs on
the same wattage. the inside surface of the light fixture rim.
Carefully lift the globe up inside the light
fixture as far as it will go. Rotate the globe
in a clockwise direction until it is held
See next page for fan
tightly in place by the three tabs. operation instructions.
16
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Remote Control www.HunterFan.com 1.888.830.1326
r
owe
r nP
Battery Tu
Door
ON
Phillips
Head
Screw
To access the battery compartment, The remote transmitter should already be paired
remove the small Phillips head screw that to the receiver and ready to use.
secures the battery door to the transmitter Note: If your need to pair your remote, turn fan
assembly. The battery should be installed power off and back on at the wall switch. Within 3
with the positive (+) side up. Replace with a minutes, press and hold both the Fan Off button
CR2032 battery when necessary. and the High button for 4 seconds to pair the
remote. To prevent faulty operation, please
ensure all other ceiling fans within range are
turned off at the wall switch while pairing.
17
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Operation, Maintenance, & Cleaning www.HunterFan.com 1.888.830.1326
Medium
Speed
Fan
Off High
Speed
Light
Low
Speed
Reverse
Switch
Removed Tabs Rocker- Style Plate
To turn on fan, press a fan speed button. Speeds To install the transmitter cradle, remove the To switch the direction of air flow, move the
range from off (0) to high (3). Quickly press the two screws holding the switch cover plate. Do reverse switch to the opposite position. You
Light button to turn the lights off and on. not remove the cover plate. Orient the cradle will need to remove the glass to do so.
by lining up the two mounting holes with
those on the cover plate. Insert and tighten
the screws. Do not over tighten.
Note: For rocker-style cover plates, break off
the tabs by pushing outward.
18
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Operation, Maintenance, & Cleaning (continued) www.HunterFan.com 1.888.830.1326
Safe-Exit
19
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company
Troubleshooting www.HunterFan.com 1.888.830.1326
20
M3599-01 • 08/11/17 • © 2017 Hunter Fan Company