2. SPECIFICATION
2. SPECIFICATION
ITEM SPECIFICATION
-5-
-5-
For Authorized Service Technician
-6-
For Authorized Service Technician
LDF8874 / LDF8764
3-2. Display Panel
<ZI][M:MNZM[P;\MIUၦხཅ૬ᅰ
CONTROL PANEL (steam models)
-7-
For Authorized Service Technician
LDF7774 / LDS5774
<ZI][M:MNZM[P6WV[\MIUၦხཅ૬ᅰ
CONTROL PANEL (non-steam models)
Z][<W]KP8T][-6/ีුጎჭᅎ8TI\Mၦხཅ૬ᅰ
Display varies by model (LDF7774)
Cycles Normal
This cycle is for normally soiled, everyday loads.
Select your desired cycle.
Quick & dry
Auto
This is a shortened cycle that is intended for washing and dry-
This cycle senses the load size, soil amount and soil tough- ing recently used dishes or lightly soiled loads. During this
ness. This cycle is optimized to achieve the best cleaning. cycle, both spray arms will run at the same time.
Heavy
Rinse only (LDS5774)
This cycle is for heavily and hard soiled dishes.
This cycle is a quick rinse for dishes that will not be washed
Delicate immediately. This cycle will rinse dishes that have excess soil
to soften dried on residue. Rinsing the dishes will help pre-
The cycle is intended for effectively cleaning delicate items
vent odors in the dishwasher. No detergent should be used.
such as fine china and stemware.
-8-
For Authorized Service Technician
CONTROL PANEL
Spray (INTENSITY)
First, select the desired cycle. Press the Spray button repeat- note
edly until the desired spray intensity is selected. • The estimated time shown in the display does not in-
Soft ( ), Medium ( ), Strong ( ) clude delay times for heating water, etc.
• If Delay Start is selected, the display shows the delay
time in hours.
Half load • Time may vary depending on the soil level of your load.
For small loads, you may use just the upper or lower rack to
save energy. Each press of the Half Load button cycles be- Energy saving
tween upper rack only and lower rack only.
The Energy Saving option saves energy by using less water.
Delay start This option should only be used with light to medium soiled
The Delay Start feature allows you to delay the start of a se- dishes.
lected cycle. Each time the Delay Start button is pressed, the
delay time will increase an hour. The delay start time can be note
set from 1 to 19 hours, in one-hour increments. The RINSE AID symbol indicates that the rinse aid
High Temp ON/OFF needs to be refilled.
Raises the main wash temperature to improve cleaning.
Press and hold the Extra Dry and Rinse buttons simultane- POWER
ously for approximately three seconds. • Press the Power button to turn on the control panel. If no
cycle is selected within four minutes, the dishwasher will
Child lock power off.
• After the cycle is complete, the power automatically turns
The Child Lock feature helps prevent your settings from be-
off for purposes of safety and economy.
ing changed during a cycle. Selecting this feature locks all
• If there is a power surge, power outage, or disruption of
of the buttons, except for the POWER button, on the control
any kind, the PF indicator will display and power will be au-
panel. This feature does not lock the door.
tomatically turned off for safety. The cycle will need to be
To activate the Child Lock: restarted.
1. Open the dishwasher door.
Smart diagnosis
2. Press the Power button.
Should you experience any problems with your dishwasher,
3. Select the cycle (and desired options). it has the capability of transmitting data to your Smart Phone
4. Press and hold the Rinse and Spray buttons for three sec- using the LG Smart Laundry & DW Application or via your
onds. The Child Lock indicator will illuminate in the display telephone to the LG call center.
once the Child Lock is activated.
5. Close the door to begin the cycle.
warning
Digital display Steam can cause burns. Use caution in the area of the steam noz-
zle, on the left side of the dishwasher, if the door is opened during
The Digital Display on the control panel shows the ESTIMAT-
the steam portion of a cycle. Contact with the steam or the steam
ED cycle time. When the dishwasher is powered up, the dis-
nozzle can cause burns.
play will be blank. When the cycle and options are selected,
the display will show the total estimated time to complete
those selections. During operation, the display shows the re-
maining estimated operating time.
-9-
For Authorized Service Technician
LDS5774
CONTROL PANEL
LDF8874/LDF8764
3-3. TEST MODE
CHECK PROGRAM
- 11 -
For Authorized Service Technician
LDF7774/LDS5774
CHECK PROGRAM
HALF LOAD +
No3/U02/D01 All LEDs are LDS5774
DELAY START 1 TIME Either
(Version) lighting Series only
+ POWER
Sump Sump
4 TIME All LEDs Closed
Temp(℃) Thermistor
Delay Start 5 TIME Pump RPM Drain Pump All LEDs Either
- 12 -
For Authorized Service Technician
5. PARTS
4. PARTS NAME
NAME
14
6
15
1 7
2 8
9
3 16
10 17
4 11
18
5 12
19
13
1. CONTROL PANEL
2. DOOR HANDLE
Mesh filter
3. FRONT COVER
4. LOWER COVER
5. LEVELING FEET 20 Outer filter
6.
Upper STS
7. BASE filter
- 11 -
- 13 -
For Authorized Service Technician
- 14 -
For Authorized Service Technician
LDF7774/LDS5774
Program Chart
- 15 -
For Authorized Service Technician
6. HOW
7. HOW TO
TO DISASSEMBLE
DISASSEMBLE
BEFORE DISASSEMBLING THE DISHWASHER ;
1) Remove the cord from electric outlet to avoid electric shock.
2) Close the Water Tap (faucet).
3) Remove all dishes and items in the dishwasher.
4) Remove the Lower Rack and the Upper Rack.
5) Remove the inlet hose and drain hose connetion to avoid the hose damages.
6) Prepare some towels to avoid floor wet by the water left in the dishwasher.
Lower Cover
2. Tub Felt
1) Tub Felt
- 13 -
- 16 -
For Authorized Service Technician
(LDF**** Series)
3. Door Assembly
1) Front Cover
Open the door.
Remove 2 screws at the bottom.
Remove 12 screws(stainless).
Controller
- 17 -
- 14 -
For Authorized Service Technician
(LDS**** Series)
Controller Latch
Assembly
Controller
- 18 -
For Authorized Service Technician
3) Fan Assembly
Gasket Inner Cover
Open the door.
Detergent
Dispenser Remove 4 screws and a earth screw for
Fan Assembly Door Bracket.
Remove the wire connetions.
Air Duct Remove the Air Duct.
Turn the Inner Cover counterclockwise.
Hose
4) Detergent Dispenser
Flange
Close the door
Remove the wire connections.
Door Hinge Remove 6 screws with brackets.
Push the Detergent slowly pulling up the
the Flange by Standard Screwdriver.
Door Bracket
6) Door Liner
Open the door.
Pull the Door Liner and take it off from
the Hinge Supporter.
Hinge Supporter
- 15 -
- 19 -
For Authorized Service Technician
4. Lower Frame
1) Press the holder hook as shown in figure.
2) Remove 4 screws.
3) Hold the lower frame by one hand.
Push the base cabinet inside from other hand.
Pull the lower frame out.
Lower Frame
Lead Wire Holer
5. Tub Assembly
1) Rack
① Remove the top. rack and the
upper / lower rack
- 16 -
- 20 -
For Authorized Service Technician
3) Sump Assembly
① Remove the wire connections.
② Remove 2 hoses assembly.
. between sump and tub.
③ Rotate 2 holders
④ Lift up sump assembly.
⑤ Remove the wire connections in the back
of the sump assembly.
- 17 -
- 21 -
.
.
For Authorized Service Technician
6) Steam Nozzle
① Remove side 4 screws.
② Push the steam nozzle.
- 18 -
- 22 -
For Authorized Service Technician
Nut
Foot
- 20 -
- 23 -
For Authorized Service Technician
7. Sump Assembly
1) Heater
① Remove the wire connections.
② Pull the heater out of the sump after
releasing the nut.
4) Vario Valve
① Remove 6 screws on the nozzle holders.
② Lift up nozzle holders.
③ Lift up Vario Valve.
- 21 -
- 24 -
For Authorized Service Technician
7. TROUBLESHOOTING
8.TROUBLE SHOOTING METHODS
METHODS
A. TROUBLE SHOOTING ACCORDING TO DISPLAYED ERROR MESSAGE
DRAIN ERROR The Drain Hose kinked or blocked. Remove the cause of kink or block.
Wiring connection is OK? Check the wiring connection.
The drain outlet of sump is Measure the electric resistance of
blocked. Drain Motor. (20-40 )
The Drain Pump/Motor or circuit is Replace the Drain Motor or repair
displayed troubled. the Circuit.
No drainage though drain pump is Remove all the water remained in
Condition working properly? Air in the the drain hose that is connected to
Not fully drained out in impeller of the drain pump might the drain pump / motor.
spite of 5 min. drain cause this case. Keep the unit upright, don't lay it
operation down.
Cautious about leaking on the floor.
The Air gap is clogged. Clean the air gap.
Knockout plug of garbage disposal Remove knock out plug.
not removed.
LEAKAGE ERROR Water leakage in Hose connections. Replace the connections of Hose.
Water is leaked by damages. Check the point of damages and
repair or replace the related parts.
or The Motor Water Seal leakage of Read the Installation Instructions
Sump assembly. (page 44) and fix it to the
displayed recommended Height.
The height of Drain Hose connection Replace the Impeller of the
Condition (sink-Drain Hose) is not over 20 . Washing Pump.
The excessive RPM of Impeller of the Washing Pump is Change the float assembly.
Washing Motor worn away.
happened during Wash The float assembly is not working. Replace the lower tub gasket.
cycle due to water
leakage. The lower tub gasket came ※ Remove water near the Float
loose or fell off. ASM before the repair.
--
2225- -
For Authorized Service Technician
THERMAL ERROR The Inlet Water Temperature is Check the temperature. (Test Mode)
very high. (over 194 ) If the temperature is displayed,
adjust the Inlet Water
Wiring connection is OK? Temperature to 120 .
displayed The Thermistor is OK? If the temperature is not
displayed,
Condition check the wiring connection.
The resistance of ther- check the electric resistance
mistor not normally out put. of Thermistor.
(11~14k at 77 )
Replace the PCB.
HEATER ERROR The Circuit of Heater is troubled. Repair the Circuit of Heater.
The Thermistor is troubled. Replace the Thermistor.
The Heater is shorted. Replace the Heater.
displayed
The Relay Circuit is troubled. Repair the Relay Circuit..
Condition
The water is not heated or
the temperature in the Tub
is overheated to over 194ßF
- 26 -
For Authorized Service Technician
Steam Generator Error mode is not displayed in normal condition and it can be confirmed
by following additional operation.
To confirm steam generator error, press the SPRAY and HALF LOAD buttons simultaneously.
When Steam Generator is out of order, dishwasher operates the selected cycle without
steam.
The generator heater temperature Check the water level sensor and
SE1 is high. (over 239 ) thermistor check.
Not reached to the normal water Check the inlet valve and sensor
SE3 level. connection. .
- 24 -
- 27 -
For Authorized Service Technician
Inlet Error
Condition.
Not reached to the normal water level
in spite of 10 min. water supply.
Is displayed?
Yes
Yes
Yes
Is the water pressure
very low or high?
Yes Install the pressure pump.
No (below 0.5kgf/㎠(20bar),
above12kgf/㎠(120bar))
No
Yes
- 28 -
For Authorized Service Technician
Drain Error
Condition.
Is displayed? Not fully drained out in spite of 5 min.
drain operation.
Yes
Yes
Is the resistance vales between
connectors out of range?
No Replace the drain
(range is 4~5Ω) motor
(Yellow 3P, pin1~pin2~pin3)
Yes
Is the connector connected to
drain motor disconnected Yes Reconnect or
or disassembled? repair the connector.
- 29 -
For Authorized Service Technician
Leakage Error
Condition.
Is or The water level in Tub goes down
displayed? during operation or standby mode.
Yes
Is the water flooded
in the base?
Water is not flooded Water is flooded
in the base. in the base.
How to check.
Disassembly the lower cover.
- 30 -
For Authorized Service Technician
Excess Error
Condition.
Is displayed? Excessive water is supplied than normal water
level. (Automatically drain Pump operated.)
No
Is the voltage between connectors
out of range? (NA8 pin1 ~ pin2) No Replace the main
- After remove terminal position PCB assembly
assurance (TPA) of connector,
check the voltage when water is
injected.
(The voltage is 2.5V AC (±15%)
Yes
- 31 -
For Authorized Service Technician
Thermal Error
Condition.
Is displayed? The resistance of thermistor not
normally out put.
Yes
No
No Is the thermistor operated
Yes Replace the
properly?
Is the resistor between Yes Replace the (range is 12~13kΩ)
thermistor.
connectors out of range? main PCB
(RD6 pin2 ~ pin3) assembly.
- After remove the
connector from the PCB,
check the resistor.
(range is 12~13kΩ)
No
- 32 -
For Authorized Service Technician
Heater Error
Condition.
The water is not heated
or the temperature
Is displayed? in the inner tub is
overheated to over 95℃
Yes
Is the heater resistance
Measured properly?
Yes (range is 11~12.5Ω) No
No
When door is closed, check
No Reconnect or
the resistor between repair the
X1 4pin and X2 4pin. trans cable.
`
Yes
- 33 -
For Authorized Service Technician
Yes
- 34 -
For Authorized Service Technician
Yes
Replace the
Is the voltage between connectors Yes main PCB
out of range? assembly.
(WH4 pin1 ~ WH4 pin4)
- After remove terminal
Main PCB assembly : WH4 position assurance (TPA)
of connector, check the voltage,
Yes when just power
on. (The voltage is 8~15V)
Replace the
Is the resistance vales Yes main PCB
short? (0~50Ω) assembly.
(After pull out the RD3
connector, check the
housing connector
(Pin1~Pin2, Pin2~Pin3,
Pin3~Pin1) individually.
No
Remove the
Yes cause of
Is the motor blocked?
block or
replace the
motor.
No
- 35 -
For Authorized Service Technician
Nozzle(Vario) Error
Condition.
The position of vario cam is not
Is displayed?
properly.
Yes
Check the connectors below. No Reconnect Does the vario S/W assembled properly? Yes Reassemble
Is the connector or repair the vario S/W.
disconnected or disassembled? connector.
(BL4 : vario motor,
NA8 : Vario S/W sensing)
No
Yes
Yes
- 36 -
For Authorized Service Technician
No Power
Yes
Yes
No Replace the
Is the current rating of multi-outlet power No Alternate
with
Is LED on while the power is on? main PCB
assembly.
strip enough? explanation.
(Avoid connecting several electric devices )
Yes
Yes
Is nine pin wire of display Yes Replace the
display PCB
PCB Assembly broken? (CON1)
assembly. Is the connector connected to PCB/Noise No Reconnect
or repair the
filter disconnected or disassembled? connector.
No
- 37 -
For Authorized Service Technician
No
After washing, is there
any streaks on the dishes
Yes Reduce the amount of Rinse aid.
or inner tub?
No
- 38 -
For Authorized Service Technician
No
No
Is the drying result of a) Does the upper nozzle fit properly
cups & glasses not Yes to the water guide?
satisfactory? (Upper basket) → Reassemble or replace
the upper nozzle or water guide
No b) Does the water guide fit properly
to the sump?
→ Reassemble or replace
the water guide.
- 39 -
For Authorized Service Technician
YES
The Fuse or NO
Circuit Breaker • Replace the Fuse or Circuit Breaker of house.
of house is O.K?
YES
YES
C h e c k t h e C o n t r o l l e r. ( P o w e r C i r c u i t )
- 40 -
- 25 -
For Authorized Service Technician
YES
YES
YES
- 41 -
- 26 -
For Authorized Service Technician
YES
After washing, are there still
White deposits or streaks on Reduce the amount of Rinse-Aid
the dishes? (for Streak)
NO
YES
-- 42
27--
For Authorized Service Technician
- 28 -
- 43 -
For Authorized Service Technician
9.8.INSTALLATION
INSTALLATIONINSTRUCTION
INSTRUCTION
Ensure the floor under the dishwasher is at the same level as the rest of the room to
allow for any service requirements.
- 44 -
- 29 -
For Authorized Service Technician
WARNING
For personal safety, remove house fuse or open circuit breaker before installation.
Do not use an extension cord or adapter plug with this dishwasher.
Electrical and grounding connections must comply with the national electrical
code/provincial and municipal code and/or other local codes.
1. This appliance must be operated with correct voltage as shown in this manual and on the
rating plate, and connected to an individual, properly grounded branch circuit, protected
by time delay fuse. Wiring must be 3 wires including ground.
2. The wiring or cord should be in an accessible location adjacent to, and not behind the
dishwasher and within 4 ft. (1.2m) of the dishwasher side.
3. The wiring or cord must be grounded properly, if in doubt, have it checked by a qualified
electrician. No other appliance shall be connected to the same outlet by a double adapter
or similar plug.
4. The wiring or cord must be oriented as shown in Figure A below.
5. Check the dishwasher for any damage before trying to install it.
6. Make sure water line and Electrical line are oriented in the bottom channels as shown in
the figure below.
If you find any damage to the dishwasher, Please contact your dealer or builder
immediately.
Figure A
- -30
45- -
For Authorized Service Technician
1. This dishwasher may be connected to either hot or cold water. If the water can not be
maintained below 149 (65 ), the dishwasher must be connected to cold water.
2. When connecting the dishwasher water line, sealing tape or compound should be used to
avoid leaks.
3. When connecting the dishwasher water line, the house supply should be shut off.
4. The Water Supply Tube must be oriented as shown in Figure A on page 6.
1. Adjust the legs to the required height to fit properly under the countertop as shown below.
2. Check the level of dishwasher by using level.
Left side – turn the Right side – turn the Front feet can be adjusted
adjusting screw adjusting screw clockwise from the top using a 1/4
counterclockwise to lower to lower the leg and raise square drive wrench.
the leg and raise the rear the rear of the dishwasher.
of the dishwasher.
- -31
46- -
For Authorized Service Technician
- -3247- -
For Authorized Service Technician
1. If the end of the drain hose does not fit to the drain line, use an adapter (not supplied) that
must be resistant to heat and detergent and may be obtained from a plumbing shop.
2. There are 2 typical connections as shown in Figures C & D.
There may be other options than shown here for connection the drain hose. The drain
connection must meet local plumbing regulations.
The S trap spigot must be drilled out cleanly and free of obstruction to its maximum
internal diameter, if used for drainage.
To prevent syphoning, one of the following instruction methods must be followed:
Drain Requirements
- -33
48- -
For Authorized Service Technician
Junction Box
- -3449- -
For Authorized Service Technician
- -35
50- -
For Authorized Service Technician
9. EXPLODED
10. EXPLODED VIEW
VIEW
- 51 -
For Authorized Service Technician
LDF8874
EXPLODED VIEW
EXPLODED VIEW
E005
F101 E010
F001
A040 A003
A130
M050
M051 M053
E005
M052
M054
- 52 -
- 37 -
For Authorized Service Technician
LDF8764
EXPLODED VIEW
EXPLODED VIEW
E005
F101 E010
F001
A040 A003
A130
M050
M051 M053
E005
M052
M054
- 37 -
- 53 -
For Authorized Service Technician
EXPLODED VIEW
E005
F101 E010
F001
A040 A003
A130
M050
M051 M053
ACCESSORIE S
E005
M052
M054
- -37 -
54 -
For Authorized Service Technician
LDF8874
EXPLODED VIEW
EXPLODED VIEW -- TUB ASSEMBLY
F110
F113 F117
F060 F040 F111
F050
F112
F022
F117
F230 F111
F300 F210
F041 F118
F113
F171
F011
F013
F144
F132
F137
F143
F166 F138
F117
F165 F215
F117 F011
F105
M006
M070
F013
M071
- 55 -
For Authorized Service Technician
LDF7774 / LDS5774
EXPLODED VIEW--TUB
EXPLODED VIEW TUBASSEMBLY
ASSEMBLY
F110
F113 F117
F111
F060
F040
F112
F117
F050
F111
F022 F210
F118
F113
F041
F171
F011
F013
F144
F132
F137
F143
F166
F138
F117
F165 F215
F117
F105 F011
M006
M070
F013
M071
- 56 -
- 38 -
For Authorized Service Technician
LDF8764
EXPLODED VIEW - TUB ASSEMBLY
EXPLODED VIEW - TUB ASSEMBLY
F060
F040
F050
F230
F022 F300
F041
F171
F011
F013
F144
F132
F137
F143
F166 F138
F117
F165 F215
F117
F105 F011
M006
M070
F013
M071
- 57 -
- 38 -
For Authorized Service Technician
LDF8874 / LDF8764
EXPLODED
EXPLODED VIEW- BASE
VIEW - BASEASSEMBLY
ASSEMBLY
F047
M500
F046
M210
M090
M100
A160
M260
F149
M105 F148 M266
- 58 -
For Authorized Service Technician
M090
M100
A160
F148
M260
M210
F149
M105 M266
- 39 -
- 59 -
For Authorized Service Technician
F192
A165 F004
A159
A156 A080
A151
F005
A157
A158
A145 A155
A070
A101
A102
A060
A103
A150
A050 F191
A110
A140
- 60 -
For Authorized Service Technician
EXPLODED
EXPLODEDVIEW
VIEW- CUTLERY
- CUTLERYRACK
RACKASSEMBLY
ASSEMBLY
A170
A171
A172
A152
- 61 -
For Authorized Service Technician
K260
K207
K215
K280
K270
K280
K251
K254
K124
K005 K002
K141
K010 K140
F142
F141
F174
K030
- 62 -
For Authorized Service Technician
LDS5774
K222 K260
K252
K251
K280
K030
K110 K121 K122
K101
K001
K100
K124
K217
K002
K141
K
K140
F142
F141
F174
- 63 -
For Authorized Service Technician
A120
M072 M070
M074 M125
M120
M071
M025
M126
M081
M087
M089
M075
M031
M091
M028
M060 M026
M027
M006
M030
M130
M088
M131
M133
M132
M134
- 64 -
BK BN RD OR YL GN BL VT GY WH BK BN RD OR YL GN BLVT GY WH PK
Display PCB Display PCB
Power Button 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 11 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9
GN YL OR RD BN BK
LED Supporter
6 5 4 3 2 1
1 2 3 4 5 6 1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 X3 RD
NO NO
YL
NA6 NA9 COM COM
Note : All Switch are Normally Closed / Press Button & Switch OPENS!
Main PCB X2 BL
NO NO
BN
COM COM
1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5 6 1 2 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6
YL
WH BL SB RD BL
YL/ VT
GY BL BN BL
GN RD SB
GY YL
RD BL VT GY
YL SB BL WH BL Float WH BK
RD
BK WH S/W
10. WIRING DIAGRAM
1 2 3 3 2 1 120 ± 10% 1 2 3
BL BK
OR 2 1 Vac 1 2 BK
1 2 1
Turbidity
U V W
Steam Steam 2 1 Sensor
BL BLDC Flow
Wash Wash Meter Vario 5 Vdc
Level Drain S/W
Level
Motor 12 Vdc
- 65 -
(Low) (High ) 1 2 1 2 120 ± 10% Rinse
7~13 Thermistor Vac Refill
4~5 Ω
5 Vdc 5 Vdc NA8 (Steam)
Inlet V/V Inlet V/V YL3
VT to BL Thermistor
(Steam) (Sump) 1 2 SB to BL 49 ± 5%
BL(2) to BL(3) (Sump )
BL to WH
12 Vdc 12 Vdc BL to VT RD
Dispen WH to SB 12~13
25 ± 5% Ω 25 ± 5% Ω
-ser RD6
BL6 BL6
BL to RD
RD to BL OR to BL
Door WH
RD S/W COM
(1/2) BK BL
RD BK BK BK
120 ± 10%
NO Pressure Sump Heater Pressure
Vac
S/W 11 ~ 12.5 Ω S/W
YL 120 ± 10% 120 ± 10%
BL Door NC Working : 120 ± 10% Vac
GY Vac Vac
S/W Stop : 0 ~ 1 Vac BN
(2/2) YL RD YL
X1 WH to X2 BL
1 2 120 ± 10% NC
GY NO
WH SB BL VT BK RD Vac RD Steam Heater
COM
Fan Vario 120 ± 10% Vac
1 2 3 4 5 6 7 RD
Motor Motor
BN
U V W Ha Hb G Vcc 120± 5% Ω 12 ~ 15 BN
N 120 ± 10% Vac Working : 120 ± 10% Vac
Stop : 0 ~ 1 Vac BK
D 3 3 N BN
Wash BL4
RD to BL
motor 2 2
WH1 1 L BK
5~20 Ω 8 ~ 15 Vdc Power Code WH1 Fuse RD1
RD3 WH4 120 Vac / 60Hz Noise Filter
WH to BL RD to BK (Voltage Input) 0Ω
BL to SB VT to BK (Pulsing Signal) WH1 WH to RD1 BN
SB to WH GY to BK (Pulsing Signal) WH1 BK to RD1 BK
Function Test while operating; Wiring Color Legend NOTES Error Message
Press Auto & Dual Control = Water Temp. Test Mode • IE – INLET ERROR
BK – Black BL – Blue BN – Brown GN – Green GY – Gray • Press Auto & Heavy & POWER • OE – DRAIN ERROR
Press Auto & Heavy = Water Supply Frequency OR – Orange PK – Pink RD – Red SB – Sky Blue WH – White
Press Auto & Delicate = Steam Temp. • Press Delay Start 1Time to 12Times • AE or E1 – LEAKAGE ERROR
V – Violet YL - Yellow • FE – EXCESS ERROR
Press Dual Control & Heavy = Wash Motor RPM
Press Quick & Dry & Extra Dry = Drain Motor RPM Component Tests • tE - THERMAL ERROR
Press Dual Control & Normal = Vario Position • Voltage Tests with connectors installed • LE – MOTOR ERROR
Press Auto & Delicate & Power = IPM Temp. • Ohm Tests with connectors removed • HE – HEATER ERROR
• nE – VARIO ERROR
(LDF8874,LDF8764 Series)
For Authorized Service Technician
BK BN RD OR YL GN BL VT GY WH BK BN RD OR YL GN BLVT GY WH PK
Display PCB Display PCB
Power Button 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 11 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9
GN YL OR RD BN BK
LED Supporter
6 5 4 3 2 1
1 2 3 4 5 6 1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 1 2 3 4 5 6 7 8 9
NA6 NA9
Note : All Switch are Normally Closed / Press Button & Switch OPENS!
Main PCB X2 BL
NO NO
BN
COM COM
1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 5 6 1 2 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6
YL
WH BL SB GY BL BN BL
RD SB
GY YL
BL VT GY
YL SB BL WH BL Float WH BK
RD
S/W
1 2 3 3 2 1 120 ± 10% 1 2 3
BL BK
OR Vac 1 2 BK
Turbidity
U V W
2 1 Sensor
BLDC Flow
Meter Vario 5 Vdc
Drain S/W
- 66 -
1 2 Motor 12 Vdc 120 ± 10% Rinse
7~13 Vac Refill
4~5 Ω
NA8
Inlet V/V YL3
VT to BL RD Thermistor
(Sump) SB to BL
1 2 BL(2) to BL(3)
BL to WH (Sump)
12 Vdc BL to VT
Dispen WH to SB 12~13
25 ± 5% Ω
-ser RD6
BL6
BL to RD
OR to BL
Door
RD S/W COM
(1/2) WH
RD 120 ± 10%
NO
Vac
YL Door NC
GY BL BK BK BK BL
S/W BK
(2/2) Pressure Pressure BN
Sump Heater
1 2 120 ± 10% NC S/W S/W
GY NO 11 ~ 12.5 Ω
WH SB BL VT BK RD Vac 120 ± 10% 120 ± 10%
RD Working : 120 ± 10% Vac
COM Vac Stop : 0 ~ 1 Vac Vac
1 2 3 4 5 6 7 Fan Vario X1 WH to X2 BL
Motor Motor
BN
U V W Ha Hb G Vcc 120 ± 5% Ω 12 ~ 15
BN
N 120 ± 10% Vac Working : 120 ± 10% Vac
Stop : 0 ~ 1 Vac BK
D BL4 3 3 N BN
Wash
RD to BL
motor 2 2
WH1 1 L BK
5~20 Ω 8 ~ 15 Vdc Power Code WH1 Fuse RD1
RD3 WH4 120 Vac / 60Hz Noise Filter
WH to BL RD to BK (Voltage Input) 0Ω
BL to SB VT to BK (Pulsing Signal) WH1 WH to RD1 BN
SB to WH GY to BK (Pulsing Signal) WH1 BK to RD1 BK
Function Test while operating; Wiring Color Legend NOTES Error Message
Press Auto & Dual Control = Water Temp. Test Mode • IE – INLET ERROR
BK – Black BL – Blue BN – Brown GN – Green GY – Gray • Press Auto & Heavy & POWER • OE – DRAIN ERROR
Press Auto & Heavy = Water Supply Frequency OR – Orange PK – Pink RD – Red SB – Sky Blue WH – White
Press Dual Control & Heavy = Wash Motor RPM • Press Half Load & Delay Start & POWER • AE or E1 – LEAKAGE ERROR
V – Violet YL - Yellow • Press Delay Start 1Time to 9Times • FE – EXCESS ERROR
Press Quick & Dry & Extra Dry = Drain Motor RPM
Press Dual Control & Normal = Vario Position • tE - THERMAL ERROR
Press Auto & Delicate & Power = IPM Temp. Component Tests • LE – MOTOR ERROR
• Voltage Tests with connectors installed • HE – HEATER ERROR
• Ohm Tests with connectors removed • nE – VARIO ERROR
(LDF7774, LDS5774 Series)