Featuring Coreless Element Technology

9900/01/04 Series
Filter Assemblies
Flows to 250 gpm (910 L/min) BLEED PORT OPTIONAL
DIFFERENTIAL
Pressures to 6000 psi (414 bar) AND PLUG
PRESSURE
DEVICES
Port sizes 11⁄2" and 2"
Notes and Specifications
Maximum Acceptable FULL FLOW
Working Pressure: 6000 psi (414 bar) FAST RESPONSE
BYPASS VALVE
Fatigue Pressure Rating: 3000 psi (207 bar)
(NFPA/T2.6.1-1974
category 2/90)
Typical Burst Pressure: 15,000 psi (1035 bar)
Temperature Range: Nitrile seals– 45°F to 225°F
(–43°C to 107°C)
Fluorocarbon seals–20°F MULTIPLE O-RING
PORT
to 250°F (–29°C to 120°C) OPTIONS
SEALS
140°F (60°C) maximum in
HWCF or water-glycol fluids
Dry Weights: T length–80 lbs. (36.5 kg)
V length–108 lbs. (49.2 kg)
X length–134 lbs. (61.1 kg)
Filter Element 9400–290 psid (20 bar) ULTIPOR® III
ELEMENT
Collapse Pressure: 9901–3000 psid (207 bar) STEEL
9404–150 psid (10 bar) TUBE

DUCTILE
IRON HEAD

Pressure Drop Information


Figure 1. Housing Pressure Drop using Figure 2. Bypass Valve Pressure Drop Element Pressure Drop Factor.
fluid with 0.9 S.G. Housing Pressure drop is using fluid with 0.9 S.G. Bypass valve Multiply actual flow rate times factor to
directly proportional to specific gravity. pressure drops are directly proportional determine pressure drop with fluid at 150
to specific gravity. SUS (32 cSt), 0.9 S.G. Correct for other
viscosities by multiplying new viscosity in
SUS/150 x new S.G/0.9.
FLOW (L/MIN) FLOW (L/MIN)
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200
25 100
9400/9404 Series Element ∆P factor (psid/gpm)
-1.50 -6.0
Length KZ KP KN KS KT
20 80
D24/E24
-5.0
13" 0.19 0.09 0.07 0.05 0.04
BYPASS OPTION “B” OR “C”
15 -1.0 60 -4.0 26" 0.09 0.05 0.04 0.03 0.02
∆P(PSID)
∆P(PSID)

∆P(BAR)

∆P(BAR)

D32/E32
-3.0 39" 0.06 0.03 0.02 0.02 0.01
10 40
-.50 REVERSE FLOW VALVE -2.0 9901 Series Element ∆P factor (psid/gpm)
OUT-TO-IN DIRECTION
VALVE OPTION "C" AND "K"
5 20
ADDITIVE ∆P IN NORMAL -1.0 Length DP DT
FLOW DIRECTION FOR
REVERSE FLOW VALVE
-0 OPTION "C" AND "K"
-0
13" 0.19 0.06
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
FLOW (GPM) FLOW (GPM)
26" 0.10 0.03
39" 0.06 0.02

60
Dimensional Drawings
OUTLET
BLEED PORT
PLUG DIFFERENTIAL PRESSURE
INDICATION (OPTION "S" SHOWN)
FOR “H”
DIMENSION
2.67 IN. SEE INDICATOR
4.17 IN. 67.8 MM SECTION
4.31 IN.
109.5 MM HEAD 105.9 MM

INLET
PORT
2.50 IN. 3.125 IN.
2.20 IN. 63.5 MM
55.9 MM 79.4 MM

1.06 IN.
27 MM
SINGLE MOUNTING BRACKET
P/N 1128249
.560 IN. DIA. HOLE (DOUBLE MOUNTING BRACKET
14.2 MM AVAILABLE) 4.50 IN.
(TYP. OF 4) 6.375 IN. 114.3 MM
162 MM

TUBE
8.58 IN.
T 15.52 IN. 394.2 MM 217.9 MM
V 28.29 IN. 718.6 MM
X 41.28 IN. 1048.5 MM

9900/01/04 SERIES
6000 PSI/250 GPM
AVAILABLE WITH:
HEAVY DUTY VALVES (Y128 SUFFIX)
USE FOR HEAVY CYCLIC APPLICATIONS
6.63 IN.
168.4 MM

CAP

3.00 IN.
76.2 MM
PLUS “H” FOR DRAIN PLUG
ELEMENT REMOVAL IF TUBE
IS UNSCREWED FROM HEAD
FOR “H” DIMENSION
SEE INDICATOR SECTION
T 11.77 IN. 299.0 MM
V 24.54 IN. 623.3 MM
CLEARANCE REQUIRED FOR ELEMENT REMOVAL (9900/01)
X 37.53 IN. 953.3 MM

T 9.75 IN. 248 MM


V 22.5 IN. 572 MM
CLEARANCE REQUIRED FOR ELEMENT REMOVAL (9904)
X 35.5 IN. 902 MM

Ordering Information
Note: For heavy duty valve
Assembly P/N: H 990 (B, C or K option) add Y128
to end of part number.
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8

Element P/N: HC F
TABLE 2 TABLE 5 TABLE 6 TABLE 1

Table 1. Seal Options Table 2. Element Options Table 3. Port Style Options Table 4. Port Size Options
Code Seals Code Element Code Rating Code Port Style Code Size
H Nitrile 0 9400 290 psid (std.) D Flange SAE J518c-code 61 24 11⁄2"
Z Fluorocarbon 1 9901 3000 psid (high collapse) E Flange SAE J518c-code 62 32 2"
4 9404 150 psid (coreless)

Table 5. Filter Element Options Table 6. Length Options* Table 7. Bypass Valve Options Table 8. Differential Pressure Device Options
Code βx≥200 βx(c)=1000 Assembly Element Code Description Code Description
Code Code**
B 50 psid- 9900/04 only P Visual indicator with thermal lockout
KZ <1 2.5 T 13
C 50 psid bypass D Visual indicator with no thermal
KP 3 5 V 26 with reverse flow- lockout
KN 6 7 X 39 9900/04 only L Electrical switch (SPDT) with 6" leads
KS 12 12 * Use code in second column W Non bypass- T Electrical switch with DIN connector
for element part no. 9901 only
KT 25 22 M ‘T’ type switch with matching wiring
** Nominal length in inches K Non bypass
DP* 3 5 cap
with reverse flow-
DT* 17 15 9901 only S Electrical switch with MS receptacle
*9901 only. N No element no flow- V Combined visual/electrical
See page 17 for filter specifications. valve 9901 only with DIN connector
Valve options W,K,N require use of 3000 B Bleed plug and seal in place of
psid collapse element (series code indicator
ending in ‘l’.)
2 ‘P’ and ‘L’
3 ‘P’ and ‘S’
See page 140.

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255) ©Copyright 1998, 2000, Pall Corporation. All rights reserved. 61