1 Aggregate2 Vibration Runs vibrators on bunkers, lights on if 2 Aggregate3 Vibration vibrators run. 3 Aggregate 1 Opens the bunker lids and lets aggregate 4 Aggregate 2 discharge to the weighing band. It works 5 Aggregate 3 with 3-seconds delay for a stable weighing. 6 Aggregate 4 After 3-seconds, the attached bunker‟s lid opens&the attached lamp lights. if no discharging; control the compressor is running, control the bunker is not empty, be sure the bunker‟s lid is working properly. Only one bunker lid can be opened at the same time so you cannot open any cover before the others are closed. 7 Emergency Stop Emergency stop button of the system. The energy of the system shuts off when this button is pushed. The lock of the button must be opened with the key over it to make the system active again. Push that button if there is an emergency situation&repairing or cleaning. 8 Weighing Band Runs the weighing band. If the weighing band runs the lamp lights. If there is a problem check the weighing band pull cord. 9 Weigh Band Vibration Vibrates the weighing band. 10 Mixer‟s Lid Opens the mixer‟s lid. The lamp lights when the mixer‟s lid is opened. If the cover can‟t open, control the compressor is running, lid‟s sensor and check if there is a mechanical jamming. 11 Washing Additive Used to wash “additive weigher”. 12 Additive Bunker‟s Lid Opens the additive bunker‟s lid without any delay. The lamp lights, when the additive bunker‟s lid is opened. The weighed additive is discharged in to the mixer. If the lid doesn‟t work properly; control if the compressor is running, lid‟s sensor and check if there is a mechanical jamming. 13 Water Discharging Lid Opens the water bunker‟s lid without any delay. The lamp lights, when the water bunker‟s lid is opened. The weighed water is discharged in to the mixer. If the cover doesn‟t work properly; control if the