Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Logic elements

Part numbers 1
OR 81 521 501 81 540 001 81 540 004
Functions AND - - - 81 522 501
YES - - - -
NOT - - - -
Version On sub-base page Plug-in Plug-in On sub-base page
5/44 - 5/45 Ø 5/32˝ (4mm) Ø 5/32˝ (4mm) 5/44 - 5/45

Symbol

Characteristics
Push-in connection for semi-rigid Male/Female/Female - Ø 5/32˝ (4 mm) - -
tubing (NFE 49100) O.D. Female/Female/Female - - Ø 1/4˝ (6.35 mm) -
Color Blue Blue Blue Green
Operating pressure psi (bar) 30 > 120 (2 > 8) 30 > 120 (2 > 8) 30 > 120 (2 > 8) 30 > 120 (2 > 8)
Orifice diameter inches (mm) 0.106˝ (2.7) 0.106˝ (2.7) 0.157˝ (4) 0.106˝ (2.7)
Flow at 90 PSI (6 bars) cfm (Nl/min) 6 (170) 6 (170) 7 (200) 6 (170)
Pressure indicator ● - - ●
Switching time ms - - - -
Operating temperature °F (°C) +20 > +120 (-5 > +50) +20 > +120 (-5 > +50) +20 > +120 (-5 > +50) +20 > +120 (-5 > +50)
Mechanical life cycles 10 million 10 million 10 million
Weight grams 25 12 25 25
Pilot/pressure curves

P.p : Pilot pressure


P.a : Supply pressure

Principle of operation

OR element AND element


The output signal “S” is present when a signal at The output signal “S” is present only when signals
“a” OR “b” is present “a” AND “b” are present simultaneously.
S = a OR b S=a+b S = a AND b S=a.b

Dimensions
81 521 501 - 81 522 501 81 540 004 - 81 541 010 1-1/4" 81 540 001 - 81 541 001
(30.7)
11/16" 3/32" dia. hole
(15,5) (0 4,5)
5/32" dia.

1-1/16" 1-1/4" 13/32"


(10,7)
(Ø 4)

M4 (28) (32)
7/16"
(11)
(29 0.1)
0.590"

1-1/8"

1" (24)
(15)

(25)
1"

0.905" 1-5/8" (40)


(23) 1-5/8" (40)
7/16" (11)
9/16"
(14,5 0.1)
Use (metric) dimensions for critical data.

Other information
See page 4/8 for mounting plan for logic elements.

Products and specifications subject to change without notice.


Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
5/36
1
- - - - - -
81 541 001 - - - - -
- 81 501 025 81 501 065 81 503 025 - -
- - - - 81 504 025 81 506 025
Plug-in Standard Manual Low-ratio Standard and Low-ratio
Ø 5/32” (4) On sub-base override On sub-base inhibition On sub-base
page 5/44 - 5/45 On sub-base page 5/44 - 5/45 On sub-base page 5/44 - 5/45
page 5/44 - 5/45 page 5/44 - 5/45

Ø 5/32˝ (4 mm) - - - - -
- - - - - -
Green Yellow Yellow Orange Light grey Dark grey
30 > 120 (2 > 8) 30 to 120 (2 to 8) 30 to 120 (2 to 8) 30 to 120 (2 to 8) 30 to 120 (2 to 8) 30 to 120 (2 to 8)
0.106˝ (2.7) 0.106˝ (2.7) 0.106˝ (2.7) 0.106˝ (2.7) 0.106˝ (2.7) 0.106˝ (2.7)
5-1/4 (150) 6 (170) 6 (170) 6 (170) 6 (170) 6 (170)
- ● ● ● ● ●
- <4 <4 <4 <4 <4
+20 > +120 (-5 > +50) +20 > +120 (-5 > +50) +20 > +120 (-5 > +50) +20 > +120 (-5 > +50) +20 > +120 (-5 > +50) +20 > +120 (-5 > +50)
10 million 10 million 10 million 10 million 10 million 10 million
13 30 35 30 30 30
PSI PSI PSI PSI
75 (5) 75 (5) 75 (5) 75 (5)

60 (4) 60 (4) 60 (4) 60 (4)

45 (3) 45 (3) 45 (3) 45 (3)

30 (2) 30 (2) 30 (2) 30 (2)

15 (1) 15 (1) 15 (1) 15 (1)

(2) (4) (6) (8) (2) (4) (6) (8) (2) (4) (6) (8) (2) (4) (6) (8)
30 60 90 120 PSI 30 60 90 120 PSI 30 60 90 120 PSI 30 60 90 120 PSI

YES element NOT element


The output signal “S” is only present when the The output signal “s” is present only if the input signal
pilot is present : “a” is NOT present. The output signal is therefore the
inverse of the pilot signal.
S = a YES b S=a
S= NOT a S=a
If the supply port is connected to a 2nd input “b”, the
function obtained is called Inhibition.
S = NOT a AND b S=a.b

81 501 025 - 81 503 025 81 501 065


81 504 025 - 81 506 025
M4

1-1/4" 1-1/16"
(32) M4 (28)
0.590"
(15)
(25)
1"
0.590"
(15)

(25)
1"

0.905"
0.905" (23) 1-7/16" (36)
(23)
1-1/4" (32) Use (metric) dimensions for critical data.
To order, specify :
Standard products
1 Part number
Example : Logic elements 81 521 501
5
Standard products,
non stocked

Products and specifications subject to change without notice.


Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
5/37
Memory element

Part numbers 1
81 523 201 81 523 601
Version With pressure With pressure indicator
indicator and manual override

Symbol

Characteristics
Color Black Black
Operating pressure psi (bar) 30 > 120 (2 > 8) 30 > 120 (2 > 8)
Orifice diameter inches (mm) 0.06” (2.7) 0.06” (2.7)
Minimum memory pilot pressure psi (bar) 40 (2.5) 40 (2.5)
Flow at 90 PSI (6 bars) cfm (Nl/min) 7 (200) 7 (200)
Connection - On sub-base page 5/44 - 5/45 ● ●
Switch Time ms 29 25
Weight grams 90 90
Principle of operation
The function is that of a 4/2 valve. The appearance of signal “X1” causes
the displacement of the slide valve. The output port “x” is then put under
pressure. This state is remembered until the arrival of signal “X0”. This
signal reverses the slide valve, the output “x” is put under pressure. This
state is likewise remembered. The output :
- "x" under pressure indicates that the information in the MEMORY is
"X1".
- "x" under pressure indicates that the information in the MEMORY is
"X0".

Dimensions Dimensions of logic and memory elements


81 523 201 - 81 523 601

4 x M4 2 holes 0.126" (Ø 3.2) for location


7/32" 7/32" 0.590" (15) 1/8" (2.5 mm) deep
(5) 1-7/8" (48) (5) 1-5/8" = =
(40)
0.905" (23)
1-1/4"
(32)
.905"
(23)

1/2"
M4
M4

(12)
4 x 1/8" dia. (27)
(Ø3 max.) 1-1/16"

Viewed from above

Use (metric) dimensions for critical data.

Other information To order, specify :


Standard products
1 Part number
Example : Memory element - 81 523 201

Products and specifications subject to change without notice.


Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
5/38