Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Part numbers
Part No.
Gas condensing double boiler in a protective
housing for outdoor installation:
Hoval Cabin Slim AC
UltraGas® 2 D (250-3100)
Delivery
• Boilers with all equipment installed in protec-
tive housing, ready for installation on-site
146 1.4.2021
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Part numbers
Part No.
TopTronic® E module expansions
for TopTronic® E basic module heat generator
+
ALF/2P/4/T L = 4.0 m
ILI
ODER - Basic plug set FE module
Notice
The supplementary plug set may have to be
ordered to implement functions differing
from the standard!
Further information
see “Controls” - “Hoval TopTronic® E
module expansions” chapter
Notice
Refer to the Hoval System Technology
to find which functions and hydraulic
arrangements can be implemented.
1.4.2021 147
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Part numbers
Part No.
Accessories for TopTronic® E
HovalConnect
HovalConnect LAN 6049 496
HovalConnect WLAN 6049 498
TopTronic® E sensors
AF/2P/K Outdoor sensor 2055 889
TF/2P/5/6T Immersion sensor, L = 5.0 m 2055 888
ALF/2P/4/T Contact sensor, L = 4.0 m 2056 775
TF/1.1P/2.5S/6T Collector sensor, L = 2.5 m 2056 776
System housing
System housing 182 mm 6038 551
System housing 254 mm 6038 552
148 1.4.2021
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Technical details
Cabin characteristics
1.4.2021 149
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Technical details
Cabin characteristics
150 1.4.2021
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Technical details
Cabin characteristics
1.4.2021 151
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Technical details
Cabin characteristics
230/50 230/50 230/50 230/50
• Operating voltage V/Hz
3x400/50 3x400/50 3x400/50 3x400/50
• Electrical power consumption min./max. (incl. electric heater) W 203-3746 203-3866 271/8222 301/8282
• IP protection IP 65 65 65 65
• Expansion vessel volume l 2x50 2x50 2x50 2x50
• Flow and return dimension DN 150 150 200 200
• Safety valve dimension inlet/outlet (one per boiler) 2'' - 2 ½'' 2'' - 2 ½'' 2'' - 2 ½'' 2'' - 2 ½''
• Flue gas chimney dimension mm Ø 358 Ø 358 Ø 506 Ø 506
• Cabin weight (including boiler, with water) kg - - - -
• Construction B23P (Option: C53, C63)
• Flue gas system
- Temperature class T120 T120 T120 T120
- Flue gas mass flow at max. nominal heat input (dry) kg/h 2976 3338 3950 4460
- Flue gas mass flow at min. nominal heat input (dry) kg/h 295 650 390 450
- Flue gas temperature at max. nominal heat output and 80/60 °C 5) °C 69 70 66 68
- Flue gas temperature at max. nominal heat output and 50/30 °C 5) °C 47 49 45 46
- Flue gas temperature at min. nominal heat output and 50/30 °C 5) °C 28 29 29 28
- Max. permissible temperature of the combustion air °C 48 48 48 48
- Volume flow of combustion air Nm3/h 2438 2732 3234 3660
1)
Data related to NCV. The boiler series is tested for EE/H setting. With a factory setting to a Wobbe value of 15.0 kWh/m 3, operation in the
Wobbe value range from 12.0 to 15.7 kWh/m 3 is possible without resetting.
2) 4)
Data related to NCV. Data related to 3% of O2
3) 5)
Conversion acc. to EN 15502-1, Appendix J Technical data ascertained during the approval test
152 1.4.2021
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Technical details
Durchflusswiderstand (mbar)
50 100
Pressure drop (mbar)
20 40
Flow through both boilers Flow through both boilers
10 20
0 0
0 5 10 15 20 25 30 0 10 20 30 40 50
Volumenstrom (m 3/h)
Volume flow (m3/h) Volumenstrom (m 3/h)
Volume flow (m3/h)
Durchflusswiderstand (mbar)
50 50
Pressure drop (mbar)
30 30
Flow through one boiler
20 20
Flow through both boilers Flow through both boilers
10 10
0 0
0 10 20 30 40 50 60 70 80 90 0 20 40 60 80 100
Volumenstrom (m3/h)
Volume flow (m /h) 3 Volumenstrom (m3/h)
Volume flow (m /h)
3
120
80
Pressure drop (mbar)
70 100
Flow through one boiler
60 80
50
Flow through one boiler 60
40
30 40
Flow through both boilers
20 Flow through both boilers
20
10
0 0
0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140 160 180 200
Volumenstrom (m 3/h)
Volume flow (m3/h) Volumenstrom (m 3/h)
Volume flow (m3/h)
1.4.2021 153
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Dimensions
UltraGas® L P H
Type
UltraGas® Weight Kg
Type
D (250 - 300) 2.600
D (380 - 600) 4.000
D (700) 4.200
D (800-1060) 4.800
D (1240) 6.000
D (1400) 6.400
D (1600-2000) on demand
D (2200-3100) on demand
154 1.4.2021
Hoval Cabin Slim AC UltraGas® 2 (125-1550) Examples
Gas
connection
Safety equipment
according to norm
EN 12828
STB Pmin Pmax
T P P
T Flow heating
T T
Y10.1 Y10.2
P P
UltraGas UltraGas
HT HT inside outside
NT NT
Return heating
P Manometer
T
Thermometer
Safety valve
T
Gas valve with thermic
shut-off function
Gas filter
1.4.2021 155
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Engineering
156 1.4.2021
Hoval Cabin Slim AC UltraGas® 2 D (250-3100) Engineering
Installation instructions
Please observe the installation instructions Expansion tank
supplied with every boiler. • An adequately dimensioned expansion tank
must be provided.
• The expansion tank installed in the cabin is
Space requirements intended only for protection of the boiler.
See “Dimensions” for information • At the safety flow a safety valve and an au
tomatic exhauster are installed.
1.4.2021 157