Evaluation of The Effect of Micro-Hydroxyapatite Incorporation On The Diametral Tensile Strength of Glass Ionomer Cements - PMC

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

J Conserv Dent. 2019 May-Jun; 22(3): 266–269.

PMCID: PMC6632627
doi: 10.4103/JCD.JCD_6_19: 10.4103/JCD.JCD_6_19 PMID: 31367111

Evaluation of the effect of micro-hydroxyapatite incorporation on the diametral


tensile strength of glass ionomer cements
Farahnaz Sharafeddin, Saeedeh Karimi,1 and Zahra Jowkar2

Department of Operative Dentistry, Biomaterials Research Center, School of Dentistry, Shiraz University of
Medical Sciences, Shiraz, Iran
1Department of Operative Dentistry, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
2Department of Operative Dentistry, Oral and Dental Disease Research Center, School of Dentistry, Shiraz
University of Medical Sciences, Shiraz, Iran
Address for correspondence: Dr. Zahra Jowkar, Department of Operative Dentistry, Oral and Dental
Disease Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran. E-mail:
zahrajowkar66@gmail.com

Received 2019 Jan 6; Revised 2019 Apr 26; Accepted 2019 May 2.

Copyright : © 2019 Journal of Conservative Dentistry

This is an open access journal, and articles are distributed under the terms of the Creative Commons
Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon
the work non-commercially, as long as appropriate credit is given and the new creations are licensed
under the identical terms.

Abstract

Aim:

The aim of this study was to evaluate the effect of micro-hydroxyapatite (micro-HAP)
incorporation on the diametral tensile strengths (DTSs) of a conventional glass ionomer
cement (GIC) and a resin-modified glass ionomer cement (RMGIC).

Materials and Methods:


:
Forty disc-shaped specimens (diameter: 6.5 mm, height: 2 mm) were prepared into four
groups (n = 10) as follows: group 1, conventional GIC; Group 2, GIC + micro-HAP (15 wt
%); Group 3, RMGIC; and Group 4, RMGIC + micro-HAP (15 wt %). All the specimens
were stored in distilled water for 24 h at room temperature. The DTSs of the specimens were
measured using a universal testing machine. Data analysis was performed using one-way
ANOVA and Tukey's test (P < 0.05).

Results:

No significant difference was found in the DTS of conventional GIC with and without micro-
HAP incorporation (P > 0.05). Moreover, the DTS of RMGIC incorporated with micro-HAP
was significantly lower than that of RMGIC without micro-HAP incorporation (P < 0.05).

Conclusions:

Micro-HAP incorporation did not affect the DTS of conventional GIC. The DTS of RMGIC
was negatively influenced by the micro-HAP incorporation. Conventional GIC (with and
without hydroxyapatite) exhibited a lower DTS than RMGIC (with or without
hydroxyapatite).

Keywords: Diametral tensile strength, glass ionomer cement, micro.hydroxyapatite, resin-


modified glass ionomer cement

INTRODUCTION

Glass ionomer cements (GICs) have many applications in dentistry because of their unique
properties.[1,2] GICs have an anticariogenic property, the ability to release fluoride, chemical
adhesion to the tooth structure, minimal microleakage at tooth–restoration interface, low
shrinkage coefficient, low cellular toxicity, and similar coefficient of thermal expansion and
modulus of elasticity to the tooth structure.[3,4,5] However, one of the most significant
shortcomings of GICs is their poor physical properties such as low flexural strength and low
fracture resistance which prevent their use in high stress-bearing areas.[6]

To overcome some of the shortcomings of GICs, resin-modified glass ionomer cements


(RMGICs) have been introduced which have a higher initial strength than the original
formulations.[7] Moreover, different filler particles such as silver, stainless steel powder,
aluminosilicate fibers, and hydroxyapatite have been previously incorporated into GICs to
improve their mechanical properties.[8,9]
:
In recent years, hydroxyapatite powders have been produced at different sizes and added to
GICs to improve their physical and mechanical properties. Hydroxyapatite
(Ca10[PO4]6[OH]2) is considered as the principal mineral component of enamel and
comprises over 60% of the weight of dentin.[10] Considering the high biocompatibility of
hydroxyapatite, some researchers have made attempts to evaluate the effects of incorporating
hydroxyapatite powder into restorative dental materials such as GICs.[8,11,12,13,14] The
interaction between GICs and hydroxyapatite takes place through carboxylate groups in the
polyacid structure. It has been reported that hydroxyapatite incorporation into GICs may
improve the mechanical properties of GICs. An increase in the bond strength of GIC to the
tooth structure can also occur due to similarity of hydroxyapatite to the structure of enamel
and dentin.[12,13]

Mechanical strength is one of the most important factors in analyzing the clinical success of
restorative materials. The diametral tensile strength (DTS) test is an easy technique to
determine the tensile strength of brittle materials such as GICs.[15] However, to our
knowledge, there is no published study investigating the effect of micro-HAP incorporation
into GIC and RMGIC on the DTS of the mentioned cements. Therefore, the present study
was undertaken to compare the DTS of a conventional GIC and a RMGIC with and without
hydroxyapatite incorporation.

MATERIALS AND METHODS

In this experimental study, 40 disc-shaped specimens (6.5 mm in diameter and 2.5 mm in


height) were prepared.

The powder and liquid of a conventional GIC (GC Fuji II, GC Corporation, Tokyo, Japan)
with the powder-to-liquid ratio of 1.8:1.0 were mixed for 20 s on a cold slab with a plastic
spatula according to the manufacturer's instructions to prepare the specimens of Group 1 (n
= 10). Then, the cylindrical brass molds [Figure 1] were overfilled with the experimental
mixture and a Transparent Mylar Matrix (M-TP, Pulpdent Corporation, USA) was placed on
the upper surface of the mold until the complete setting of the GIC (10 min).

In Group 2, the specimens contained 85% conventional GIC with 15 wt% of micro-
hydroxyapatite (micro-HAP). The conventional GIC (85 wt %) and micro-HAP (Sigma-
Aldrich, St. Louis, USA) (15 wt %) were weighed carefully using a weighing machine
accurate to 0.0001 g (A and D, GR + 360, Tokyo, Japan). Then, micro-HAP was added to
the GIC and mixed in the amalgamator (Ultramat, SDI, Bayswater, Victoria, Australia) using
clean amalgam capsules for 20 s to have a uniform mixture. Then, the mixing and
preparation of the specimens were done as described for Group 1.
:
In Group 3, the discs were prepared from RMGIC powder (GC, Tokyo, Japan) which was
mixed with liquid according to the manufacturer's instructions with the powder-to-liquid ratio
of 3.2:1 by weight. Then, the molds were overfilled as mentioned above. The upper surface
of each sample was then light cured for 40 s using a halogen light-curing unit (BlueLEX,
Monitex, Taiwan) with a light intensity of 470 mW/cm2 according to the manufacturer's
directions. The curing tip was placed at a 1-mm distance from each side of the sample.

Group 4 consisted of RMGIC with 15 wt% of micro-HAP. The samples were prepared and
evaluated as described for Group 3. After complete setting, all specimens were removed from
the mold and the samples were coated with varnish to be protected against moisture.

Then, all the specimens were stored in distilled water at room temperature for 24 h. The
upper and lower surfaces of the samples were polished with 600-grit sandpaper. Before
performing the test, the diameters and heights of all the samples were measured with
calipers. Then, the samples were subjected to diametral forces in a universal testing machine
(Zwick-ZOB, Germany) at a crosshead speed of 0.5 mm/min. The data were analyzed with
one-way ANOVA and Tukey's test (P < 0.05).

RESULTS

The mean DTSs of the experimental groups are presented in Table 1.

One-way ANOVA showed significant differences in the DTSs of the four groups (P <
00001).

Based on the results of two-by-two comparisons using Tukey's test, HAP incorporation did
not affect the DTS of the conventional GIC (P = 0.99). However, the DTS of RMGIC was
higher than that of RMGIC incorporated with HAP (P < 0.0001).

The DTS of the conventional GIC was significantly lower than those of RMGIC and RMGIC
with hydroxyapatite (P < 0.001). Furthermore, the DTS of the conventional GIC
incorporated with HAP was lower than those of RMGIC and RMGIC incorporated with
HAP (P < 0.001).

DISCUSSION

The results of the present study showed that incorporation of 15 wt% of micro-HAP into
conventional GIC did not affect the DTS of the conventional glass ionomer. However, the
DTS of RMGIC was significantly decreased after micro-HAP incorporation.
:
Some previous studies have reported that the incorporation of hydroxyapatite into GICs
could improve the mechanical properties and bond strength to tooth structure.[5,16,17]
Moreover, the fluoride ion release was improved after HAP incorporation into GIC.[18]
Considering the positive effects of HAP incorporation into GICs, the effect of HAP
incorporation on the DTSs of GIC and RMGIC was evaluated in the present study. It has
been previously demonstrated that the incorporation of 15 wt% of micro-HAP into RMGIC
improves microhardness, while the addition of 15 wt% of HAP has a negative effect on the
microhardness of RMGIC.[13] Therefore, 15 wt% of micro-HAP was incorporated into a
conventional GIC and a RMGIC in the present study. The bioactive hydroxyapatite
(HAP)/zirconia-filled GIC demonstrated increased DTS and compressive strength compared
to the unmodified GIC in a previous study.[16] In addition, the incorporation of nano-
hydroxyapatite and fluorapatite into the structure of conventional GIC resulted in a higher
compressive strength, DTS, and flexural strength compared to conventional GIC.[5] In
addition, conventional GIC containing 4 wt% HAP exhibited higher DTSs and compressive
strengths compared to conventional GIC without HAP particles.[19] The DTS of the GIC
containing 20 wt% HAP was significantly higher than that of GIC containing 10, 15, 25, and
30 wt% synthetic hydroxyapatite in a previous study. This result was attributed to the
chemical reactions between polycarboxylic acid and hydroxyapatite and the formation of
strong chemical bonds following HAP incorporation into GIC.[20] In contrast to the
mentioned studies, 15 wt% micro-HAP incorporation did not affect the DTS of GIC and
decreased the DTS of RMGIC in the present study. This difference might be attributed to the
different types of HAP which were used. In the current study, micro-HAP (Aldrich, Sigma,
USA) dissolved in distilled water was used without being heated.

On the other hand, the effect of the incorporation of HAP nanoparticles on the flexural
strength of RMGIC at 0, 1, 2, 5, 7, and 10 wt% was previously evaluated and demonstrated
that the groups with up to 5 wt% HAP exhibited an increase in the flexural strength.
However, the flexural strengths of the groups with more than 5 wt% HAP were significantly
lower than that of the control group.[21] This decrease was attributed to the formation of the
agglomerates of HAP nanoparticles in the matrix and the resultant increased porosity which
might serve as a weak point, resulting in a decrease in the flexural strength of the mixture.
Moreover, it has been demonstrated that nanoparticles at high wt% function as nonreactive
fillers and can interfere with acid–base reactions.[22] Furthermore, excess water can
penetrate the space between the agglomerates of HAP nanoparticles in the matrix and finally
result in decreased strength.[22] These explanations may justify the findings of the present
study which showed no improvement in the DTS of the GIC incorporated with 15 wt%
micro-HAP incorporation.

In the present study, 15 wt% micro-HAP resulted in a decrease in the DTS of RMGIC. 15
wt% micro-HAP incorporation into RMGIC might serve as a weak point and compromise the
mechanical properties of the cement. In contrast to the present study, some previous studies
:
found that the DTS of the GIC incorporated with HAP increased.[5,16,19] This difference
may be due to the lower wt% of the HAP incorporated with the GIC in the mentioned studies
compared to the current study.

In this context, it has been reported that the incorporation of HAP up to 5 wt% does not
affect the compressive strength of GIC. However, higher concentrations of HAP resulted in
decreased compressive strength.[23] Generally, the scanning electron microscopy and
Fourier transform infrared spectroscopy have shown that the presence of HAP in the
structure of GIC decreases the number of acid–base reactions during the cement's setting
reaction. Therefore, more calcium ions are released from the cement surface at the beginning
of the immersion, and the dissolution of calcium ions inhibits the inhibitory effect of
polycarboxylic acid to form apatite. As a result, nonhomogeneous apatite crystallization
occurs in silicone and carboxyl cement groups.[4] On the other hand, due to their small size,
the use of hydroxyapatite nanoparticles in the GIC powder up to 5 wt% results in the
widespread diffusion of the HAP particles which occupy the empty spaces between the GIC
particles, serve as a reinforcing agent in the chemical structure of GIC, and finally improve
the mechanical properties.[19]

The mechanical properties of GICs incorporated with granular (rod-shaped) nanoparticles of


HAP have been evaluated in a previous study which concluded that HAP could play an
important role in improving the mechanical and bioactive properties of GICs.[4] In contrast,
no positive effect on the DTS of the GIC incorporated with the spherical HAP was observed
in the present study. This difference may be due to the fact that granular hydroxyapatite
nanoparticles have higher solubility than the spherical nanoparticles used in the present
study. This higher solubility can affect the mechanical behavior of GIC.[4]

Based on the results of the present study, the DTS of RMGIC, with and without
hydroxyapatite, was higher than that of conventional GIC. Furthermore, the incorporation of
micro-HAP into RMGIC resulted in a decrease in its DTS. It seems that HAP incorporation
can interfere with the complete reaction of the components of RMGIC which can negatively
affect the DTS.[13] However, the probable effects of different concentrations and different
particle sizes of the HAP on mechanical and bond strength properties of GICs should be
investigated in future studies.

CONCLUSIONS

The incorporation of hydroxyapatite into conventional GIC is recommended because it does


not decrease the DTS of conventional GIC and may exhibit positive biological effects.
However, the DTS of RMGIC decreased following micro-HAP incorporation.

Financial support and sponsorship


:
Shiraz University of Medical Sciences, Shiraz, Iran, supported the study.

Conflicts of interest

There are no conflicts of interest.

Acknowledgments

We thank the Vice-Chancellery of Research, Shiraz University of Medical Sciences, for


supporting this research and Biomaterial Research Center of Shiraz University of Medical
Sciences for testing the specimens (Number: 8997258). This article is based on the thesis by
Dr. Saeedeh Karimi. We thank Dr. Mehrdad Vossoughi from the Dental Research
Development Center for the statistical analyses. We also thank Dr. Arash Moradi for editorial
assistance.

REFERENCES

1. Giacomelli É, Mota EG, Oshima HM, Belle R, Hirakata LM. Development of glass ionomer cement modified
with seashell powder as a scaffold material for bone formation. Rev Odonto Ciência. 2011;26:40–4.

2. Khoroushi M, Mousavinasab SM, Keshani F, Hashemi S. Effect of resin-modified glass ionomer containing
bioactive glass on the flexural strength and morphology of demineralized dentin. Oper Dent. 2013;38:E1–10.
[PubMed: 23098663]

3. Lucas ME, Arita K, Nishino M. Toughness, bonding and fluoride-release properties of hydroxyapatite-added
glass ionomer cement. Biomaterials. 2003;24:3787–94. [PubMed: 12818551]

4. Moshaverinia A, Ansari S, Moshaverinia M, Roohpour N, Darr JA, Rehman I. Effects of incorporation of


hydroxyapatite and fluoroapatite nanobioceramics into conventional glass ionomer cements (GIC) Acta Biomater.
2008;4:432–40. [PubMed: 17921077]

5. Moshaverinia A, Ansari S, Movasaghi Z, Billington RW, Darr JA, Rehman IU. Modification of conventional
glass-ionomer cements with N-vinylpyrrolidone containing polyacids, nano-hydroxy and fluoroapatite to improve
mechanical properties. Dent Mater. 2008;24:1381–90. [PubMed: 18433855]

6. Ilie N, Hickel R. Mechanical behavior of glass ionomer cements as a function of loading condition and mixing
procedure. Dent Mater J. 2007;26:526–33. [PubMed: 17886457]

7. Mousavinasab SM, Khoroushi M, Keshani F, Hashemi S. Flexural strength and morphological characteristics of
resin-modified glass-ionomer containing bioactive glass. J Contemp Dent Pract. 2011;12:41–6. [PubMed:
22186689]

8. Sharafeddin F, Tondari A, Alavi A. The effect of adding glass and polyethylene fibers on flexural strength of
three types of glass-ionomer cements. Res J Biol Sci. 2013;8:66–70.
:
9. Sharafeddin F, Sadeghi A, Kohanteb G. Comparison of the effect of deconex (solarsept), micro 10 and cidex in
disinfecting dental instruments. J Dent Shiraz Univ Med Sci. 2005;6:38–46.

10. Goenka S, Balu R, Sampath Kumar TS. Effects of nanocrystalline calcium deficient hydroxyapatite
incorporation in glass ionomer cements. J Mech Behav Biomed Mater. 2012;7:69–76. [PubMed: 22340686]

11. Sharafeddin F, Feizi N. Evaluation of the effect of adding micro-hydroxyapatite and nano-hydroxyapatite on
the microleakage of conventional and resin-modified glass-ionomer Cl V restorations. J Clin Exp Dent.
2017;9:e242–8. [PMCID: PMC5303325] [PubMed: 28210443]

12. Sharafeddin F, Kowkabi M, Shoale S. Evaluation of the effect of home bleaching agents on surface
microhardness of different glass-ionomer cements containing hydroxyapatite. J Clin Exp Dent. 2017;9:e1075–80.
[PMCID: PMC5650208] [PubMed: 29075408]

13. Sharafeddin F, Shoale S, Kowkabi M. Effects of different percentages of microhydroxyapatite on


microhardness of resin-modified glass-ionomer and zirconomer. J Clin Exp Dent. 2017;9:e805–11. [PMCID:
PMC5474339] [PubMed: 28638560]

14. Sharafeddin F, Azar MR, Feizi N, Salehi R. Evaluation of surface microhardness of silver and zirconia
reinforced glass-ionomers with and without microhydroxyapatite. J Dent Biomater. 2017;4:454–60.

15. Brostow W, Estevez M, Lobland HE, Hoang L, Rodriguez JR, Vargar S. Porous hydroxyapatite-based
obturation materials for dentistry. J Mater Res. 2008;23:1587–96.

16. Gu YW, Yap AU, Cheang P, Khor KA. Effects of incorporation of HA/ZrO(2) into glass ionomer cement
(GIC) Biomaterials. 2005;26:713–20. [PubMed: 15350775]

17. Kantharia N, Naik S, Apte S, Kheur M, Kheur S, Kale B. Nano-hydroxyapatite and its contemporary
applications. Bone. 2014;1:15–9.

18. Lee JJ, Lee YK, Choi BJ, Lee JH, Choi HJ, Son HK, et al. Physical properties of resin-reinforced glass
ionomer cement modified with micro and nano-hydroxyapatite. J Nanosci Nanotechnol. 2010;10:5270–6.
[PubMed: 21125881]

19. Yap AU, Pek YS, Kumar RA, Cheang P, Khor KA. Experimental studies on a new bioactive material:
HAIonomer cements. Biomaterials. 2002;23:955–62. [PubMed: 11774854]

20. Rasheed M, Mohammed RA. Assessment of diametral tensile strength and microhardness of Glass ionomer
reinforced by different amounts of hydroxyapatite. J Baghdad Coll Dent. 2006;18:17–20.

21. Mohammadi Basir M, Ataei M, Rezvani MB, Golkar P. Effect of incorporation of various amounts of nano-
sized hydroxyapatite on the mechanical properties of a resin modified glass ionomer. Shahid Beheshti Univ Dent
J. 2013;30:216–23.

22. Sadat-Shojai M, Atai M, Nodehi A, Khanlar LN. Hydroxyapatite nanorods as novel fillers for improving the
properties of dental adhesives: Synthesis and application. Dent Mater. 2010;26:471–82. [PubMed: 20153516]
:
23. Khaghani M, Doostmohammadi A, Monshi A, Golnia Z. Effect of incorporating nano-particles of
hydroxyapatite on bioactivity and compressive strength of dental glass-ionomer cements. J Isfahan Dent Sch.
2013;8:539–605.
:
Figures and Tables

Figure 1

The split mold and the specimen

Table 1

The mean values of the diametral tensile strength (MPa) among different groups

Group Mean SD

Conventional GIC 8.69 0.89


Conventional GIC incorporated with micro-HAP 8.79 1.4

RMGIC 27.08 2.26


RMGIC incorporated with micro-HAP 19.72 2.15

GIC: Glass ionomer cement, micro-HAP: Micro-hydroxyapatite, RMGIC: Resin-modified glass ionomer cement,
SD: Standard deviation
:

You might also like