Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

8 3 0 0 Sa int-Pa trick, S uite 15 0 Tel.: +0 01 514.739.

1967
L a Sa lle , Q ue be c Fax: +0 01 514.739.0434
C a na da H8 N 2 H1 e- mail: sales@morganschaff er.com

Visit our website: www.morganschaffer.com

M orga n Scha ffe r is IS O /IEC 17 0 2 5 :2 0 0 5 a ccre dite d by the


S ta nda rds C ouncil of C a na da (S C C ) for a ll its oil te sting a cti v itie s .
M orga n Scha ffe r is a lso IS O 9 0 01 :2 0 0 8 ce rtifie d

Our laboratory is accredited


I S O /IE C 17 0 2 5 :2 0 0 5

Copyright 2010 Morgan Schaffer Inc. All rights reserved. The MS Morgan Schaffer Transformers – The Inside View logo is a trademark of Morgan Schaffer Inc.
Benefits
The only way to verify performance of the entire
analytical process
Provide a common base for calibration of all DGA
systems, independently of gas extraction method, gas
detection technique and equipment used
Common reference guarantees significance of data
trending using results from different laboratories
Excellent for client or laboratory assessment of analytical
performance using blind samples
TRUE NORTH DGA OIL STANDARDS
ATLANTIS MOISTURE-IN-OIL STANDARDS
DGA precision and accuracy is critical to your operation
Precise and accurate dissolved moisture-in-oil results are also crucial to your clients’ transformer maintenance
Dissolved Gas Analysis (DGA) is the most effective way of detecting incipient faults in oil-filled electrical decisions. With Atlantis, you can continuously validate the precision and accuracy of your Karl Fischer* method.
equipment. The accepted methods for performing DGA are outlined in the ASTM D3612 and IEC 60567
standards. Atlantis is manufactured according to strict quality control processes using production tools that are
traceable to NIST;
As these methods require proper calibration of laboratory equipment prior to analyzing oil samples, the use of The concentration of each Atlantis lot is determined by the method of preparation;
certified oil standards is recognized as an ideal way of verifying and maintaining the precision and accuracy of The lot is then validated using Morgan Schaffer’s ISO/IEC 17025-2005 accredited laboratory,
DGA methods. However: making it the most accurate and precise oil standard available on the market

producing such standards in-house is tedious and costly * ASTM D-1533 Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration
most laboratories have restricted their calibration process to the gas chromatograph used to analyze the gas
sample extracted from the oil
GC calibration does not address either systematic or random errors that may occur in the gas extraction True North / Atlantis Programs
phase of the analysis
The following steps are required to reach maximum efficiency in using True North / Atlantis QA tools:
- Assessment of laboratory capacity
- Assessment of laboratory work load profile
Traceability is key to your credibility - Establishing of True North / Atlantis supply schedule
- Implementation and performance tracking
Each bulk standard of True North oil is produced using NIST traceable gas concentrations and NIST traceable
calibrated balances Standards are shipped to the laboratory weekly or monthly
Bulk lots are continuously monitored for stability and nominal concentrations are validated statistically to Usage schedule is reviewed yearly and is adjusted
reach a 95% degree of confidence on the precision range stated for each gas concentration Sample concentrations used within the program are optimized to guarantee stability of the calibration curves
True North DGA Oil Standards are extracted from bulk standards on the day they are shipped Schedule designed to minimize labor and materials costs associated with running standards

A Certificate of Concentration is delivered with each sample for traceability True North Oil Standards are produced in low, medium and high concentrations*.
Standards containing gas concentrations more typical of faulty transformers are also available.

IS O/IEC 17025 :2 0 0 5 * Atlantis standards are available in low


and medium concentrations only Technical Advantages
The manufacturing process of True North Industry accepted glass syringes prevent loss of dissolved gases to
DGA Standards is performed according the atmosphere and contamination by atmospheric components
to the principles outlined in ASTM D3612, Individual cardboard packaging prevents generation of fault gases
a method to which Morgan Schaffer by exposure to light
complies in accordance with its ISO/IEC
17025:2005 Quality Management System. IATA accepted outer packaging guarantees timely and trouble free
shipping of oil standards by air, worldwide
Benefits
The only way to verify performance of the entire
analytical process
Provide a common base for calibration of all DGA
systems, independently of gas extraction method, gas
detection technique and equipment used
Common reference guarantees significance of data
trending using results from different laboratories
Excellent for client or laboratory assessment of analytical
performance using blind samples
TRUE NORTH DGA OIL STANDARDS
ATLANTIS MOISTURE-IN-OIL STANDARDS
DGA precision and accuracy is critical to your operation
Precise and accurate dissolved moisture-in-oil results are also crucial to your clients’ transformer maintenance
Dissolved Gas Analysis (DGA) is the most effective way of detecting incipient faults in oil-filled electrical decisions. With Atlantis, you can continuously validate the precision and accuracy of your Karl Fischer* method.
equipment. The accepted methods for performing DGA are outlined in the ASTM D3612 and IEC 60567
standards. Atlantis is manufactured according to strict quality control processes using production tools that are
traceable to NIST;
As these methods require proper calibration of laboratory equipment prior to analyzing oil samples, the use of The concentration of each Atlantis lot is determined by the method of preparation;
certified oil standards is recognized as an ideal way of verifying and maintaining the precision and accuracy of The lot is then validated using Morgan Schaffer’s ISO/IEC 17025-2005 accredited laboratory,
DGA methods. However: making it the most accurate and precise oil standard available on the market

producing such standards in-house is tedious and costly * ASTM D-1533 Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration
most laboratories have restricted their calibration process to the gas chromatograph used to analyze the gas
sample extracted from the oil
GC calibration does not address either systematic or random errors that may occur in the gas extraction True North / Atlantis Programs
phase of the analysis
The following steps are required to reach maximum efficiency in using True North / Atlantis QA tools:
- Assessment of laboratory capacity
- Assessment of laboratory work load profile
Traceability is key to your credibility - Establishing of True North / Atlantis supply schedule
- Implementation and performance tracking
Each bulk standard of True North oil is produced using NIST traceable gas concentrations and NIST traceable
calibrated balances Standards are shipped to the laboratory weekly or monthly
Bulk lots are continuously monitored for stability and nominal concentrations are validated statistically to Usage schedule is reviewed yearly and is adjusted
reach a 95% degree of confidence on the precision range stated for each gas concentration Sample concentrations used within the program are optimized to guarantee stability of the calibration curves
True North DGA Oil Standards are extracted from bulk standards on the day they are shipped Schedule designed to minimize labor and materials costs associated with running standards

A Certificate of Concentration is delivered with each sample for traceability True North Oil Standards are produced in low, medium and high concentrations*.
Standards containing gas concentrations more typical of faulty transformers are also available.

IS O/IEC 17025 :2 0 0 5 * Atlantis standards are available in low


and medium concentrations only Technical Advantages
The manufacturing process of True North Industry accepted glass syringes prevent loss of dissolved gases to
DGA Standards is performed according the atmosphere and contamination by atmospheric components
to the principles outlined in ASTM D3612, Individual cardboard packaging prevents generation of fault gases
a method to which Morgan Schaffer by exposure to light
complies in accordance with its ISO/IEC
17025:2005 Quality Management System. IATA accepted outer packaging guarantees timely and trouble free
shipping of oil standards by air, worldwide
8 3 0 0 Sa int-Pa trick, S uite 15 0 Tel.: +0 01 514.739.1967
L a Sa lle , Q ue be c Fax: +0 01 514.739.0434
C a na da H8 N 2 H1 e- mail: sales@morganschaff er.com

Visit our website: www.morganschaffer.com

M orga n Scha ffe r is IS O /IEC 17 0 2 5 :2 0 0 5 a ccre dite d by the


S ta nda rds C ouncil of C a na da (S C C ) for a ll its oil te sting a cti v itie s .
M orga n Scha ffe r is a lso IS O 9 0 01 :2 0 0 8 ce rtifie d

Laboratory validated by
I S O /IE C 17 0 2 5 :2 0 0 5

Copyright 2010 Morgan Schaffer Inc. All rights reserved. The MS Morgan Schaffer Transformers – The Inside View logo is a trademark of Morgan Schaffer Inc.

You might also like