Prosthetic Devices
Prosthetic Devices
Structure is the means of carrying the function, and finally both need to be embodied
into a design that is cosmetically acceptable.
Some of the fundamental issues in these concepts are
To function well, the device needs an effective coupling to the human body.
The Shapes are also evolved to achieve appropriate load distribution for stability of coupling between
prosthetic socket and limb.
Alignment is a second factor influencing the interface loading. For lower limb orthosis, the net action of
the ground reaction forces and consequent moments around the natural joints are highly dependent on the
alignment taken up by the combination of orthosis and shoe.
Adjustability may be important, particularly for children or progressive medical conditions.
Misalignment of the hindfoot
Continued……..
Not only are the load level and life critical, but so is the mode of failure. Sudden failure of an ankle
bolt resulting in disengagement of an artificial foot is not only potentially life-threatening to an
elderly amputee who falls and breaks a hip but also can be quite traumatic to unsuspecting
witnesses of the apparent event of auto amputation.
Design and choice of materials should ensure a controlled slow yielding, not brittle fracture.
A further consideration is the ability of the complete structure to absorb shock loading, either the
repeated small shocks of walking at the heel strike or rather more major shocks during sports
activities or falls. This minimizes the shock transmitted through the skin to the skeleton, known to
cause both skin lesions and joint degeneration.
Continued……..
In providing cosmesis, the views of the user
must remain paramount. The wearer will often
Finally, the consideration of hygiene must not choose an attractive functional design in
be overlooked; the user must be able to clean preference to a life
the orthosis or prosthesis adequately without
compromising its structure or function. Upper limb prostheses are a more interesting
The third element of cosmesis completes the engineering challenge than lower limb,
trilogy. An artificial arm comprise a socket with a
Appearance is a major factor and it has a great terminal device offering a pincer grip (hand or
hook) that can be operated through a Bowden
psychological importance to the user. cable by shrugging the shoulders.
As examples, to provide realistic cosmetic
covers for hand or foot prostheses.
Continued……..
Contracting remaining muscles in the forearm that would have controlled their fingers
Another, method is to take a muscle and tether its tendon through an artificially fashioned loop of
skin: the cable can then be hooked through the loop.
Power can be Pneumatic power in the form of a gas cylinder which is cheap and light
Gas-powered grip on a hand can be a good solution
Input control to these powered devices can be from surface electromyography or by mechanical
movement
The physical design in prosthetic and orthotic devices has changed substantially over the past
decade.
Computer-aided Engineering In
Customized Component Design
Computer-aided engineering has found a fertile ground for exploitation in the process of design of
customized components to match to body shape.
Example: sockets for artificial limbs - produce a well-fitting socket during the course of a single
patient consultation
Traditional methods
Casting the residual limb in plaster of Paris
Pouring a positive mold
Manual rectification and then socket fabrication over cast long process.
Continued……..
Advanced Technology Advantages
Residual limb shapes can be captured in a The shape is stored in digital form in the
computer, computer and can be reproduced or adjusted
whenever and wherever desired.
Rectified by computer algorithms, and
CNC machined to produce the rectified cast in
an hour
Vacuum-formed machinery to pull a socket
rapidly over the cast
The socket can be ready for trial fitting in one
session.
Development Stages
This stage involves the design and construction of the physical components of the prosthesis, such as the socket, knee joint, and
1) Hardware – control system. The goal is to create a device that is lightweight, strong, and durable, and performs the intended function. The
sacrificial mold is also produced in this stage.
The control of an artificial lower limb is problematic during the swing phase, during which the foot
is lifted off the ground to be guided into contact ahead of the walker.
A prosthetic lower limb needs to be significantly lighter than its normal one as the muscles do not
control them.
Two technological advances have helped.
First, carbon fiber construction has reduced the mass of the lower limb
Second, pneumatic or hydraulically controlled damping mechanisms for the knee joint have enabled
adjustment of the swing phase to suit an individual’s pattern of walking.
damping mechanisms in rehab technology works by absorbing energy during movement, reducing the impact of the movement on the user's body and improving stability and control.
Continued……..
While if the amputee walks more quickly, the limb will tend to fall behind or lag
In an intelligent system, a 4-bit microprocessor is used to adjust a needle valve, via a linear
stepper motor, according to duration of the preceding swing phase.
The unit is programmed by the prosthetics to provide optimal damping for the particular
amputee’s swing phase at slow, normal, and fast walking paces.
A Hierarchically Controlled Prosthetic
Hand
Control of the intact hand is hierarchical. It starts with the owner’s
intention, and an action plan is formulated based on knowledge of the
environment and the object to be manipulated.
For gross movements, it relies on “pre-programmed” coordination
from the central nervous system.
Fine control leans heavily on local feedback from force and position
sensors in the joints and tactile information at the skin.
In contrast, conventional prostheses depend on the conscious
command of all levels of control and so can be slow and tiring to use.
Current technology is able to provide both the computing power and
transducers required to recreate some of a normal hand’s control.
Control of the intact hand is hierarchical. Gross movements are programmed in the CNS and for small and delicate
movements (fine control), sensors in the joints and tactile information at the skin is used. In contrast, conventional
prostheses rely on a person consciously controlling all the hand movements, which can be slow and tiring to do. The
prosthetic hand may not tespond as quickly or precisely as a real hand because it lacks the natural feedback from sensors.
Continued……..
Side, or key: Digits 2 to 5 half fully flexed with thumb opposing side of second digit.
Flat hand: Digits 2 to 5 fully extended with thumb abducted and flexed, parked beside digit 2.
The controller coordinates the transition between these positions.
Potentiometers detect the angles of flexion of the digits; touch sensors detect pressure on the palmer surfaces of
the digits
Knee orthosis are often supplied to resist knee flexion during standing and gait at an otherwise collapsing joint.
The rigid locking mechanisms on these devices are manually released to allow knee flexion during sitting.
Fitting is complicated by the difficulty of attaching the orthosis with its joint accurately aligned to that of the
knee.
The simple diagram in Fig. 140.11 shows how misplacement of a simple hinged orthosis with a notional fixed
knee axis would cause the cuffs on the thigh and calf to press into the soft tissues of the limb (known as
pistoning).
Continued……..
The human knee does not have a fixed axis, though, but is better represented as a polycentric
joint.
The problem of alignment still remains, to overcome this specific problem, the knee
mechanism has been designed with not one but two axes
The center of rotation is then free to self-align. This complexity of the joint while still
maintaining the ability to fixate the knee and meeting low weight requirements is only
achieved by meticulous design in composite materials.
FES Systems
On the basis of accumulated experience, the following features can serve as criteria for a closer
description of various HAS designs: Different designs of HAS:
An "active prosthesis" is a type of prosthesis that has an external power source and control mechanism, which allows it to
move and perform specific functions more actively and efficiently as compared to a "non externally powered and controlled"
prosthesis. The objective of active prosthesis is to improve the overall performance of motor function and enhance quality of
life.
The role of active prosthesis is to extend the function provided by a “non-externally” powered and
controlled artificial organ; hence, to improve the overall performance of motor function, ultimately
providing a better quality of life.
Active Above-Knee Prostheses
Artificial legs of different kinds have been in use for a long time
But in many cases they are inadequate for the needs of amputees, specifically for high above-knee
amputations (e.g., hip disarticulation), bilateral amputees, and patients who have demanding
biomechanical requirements (e.g., subjects involved in sports)
Modern technology has led to improved designs of below-knee prostheses (BKP)
Below-knee Amputees (BKP)
Perform many normal locomotor activities and participate in many sports requiring running,
jumping, and other jerky movements
The y are made using readily available and easy-to-work-with plastic and graphite alloys for
building the artificial skeletal portion of the shank and foot
BKP are light, easy to assemble, and reliable
They provide good support and excellent energy absorption, which prevents impact, jerks, and
allows the push-off phase in the gait cycle
Without ankle joints, duplicate the behavior of the normal foot–ankle complex during swing and
stance phases of the step cycle
AKP are designed for individuals who have lost their limb above the knee. The AKP must be able to support the weight of the amputee,
provide stability during weight bearing activities, and duplicate the normal gait patterns as closely as possible. This helps to prevent
unwanted pressure on the stump and socket interfacem reduces the risk of sudden or uncontrolled knee flexion, and provides a better
qualitu of life for the amputee.
Continued……..
activities, and duplicating the kinematics and dynamics of normal gait. The final prototype of such an active self-contained AKP is capable of controlled flexion and extension throughout the gait
cycle, making it a suitable option for people with above-knee amputations.
The control signals going to the prosthesis come from the myoelectric activity of the muscle
which controls the lost limb.
In some sense, the brain’s own signals are used to control the motion of the prosthesis.
Two systems based on myoelectric control are used with success.
The Otto Bock myoelectric hand uses the technique of detection of the fixed threshold of the
integrated rectified surface electromyography. Extension/flexion of the targeted muscle group
serves as the on/off control, which causes opening and closing of the hand, respectively. Two
sets of electrodes are used to detect this differential signal.
Continued……..
The Utah arm utilizes the myoelectric signal which controls the elbow (Fig. 142.5).
The signals are full wave rectified and differentiated to give the command signal.
The Utah arm has a wrist rotator and it can be combined with different grasping systems. Most of
the artificial hands used in everyday activities do not include the five finger dexterity, except in the
devices that are mechanically pre-programmed.
An externally controlled elbow–wrist–hand prosthesis was evaluated. The shoulder joint position is
measured with a potentiometer, mounted between the upper arm and trunk.
An important feature of the system is that disabled humans can learn how to control the system
within minutes using trial-and-error procedure.
Myoelectric Hand and Arm Prosthesis
The control signals for a myoelectric prosthesis, such as an artificial arm or hand, come from the
electrical activity (myoelectric signals) of the muscles that would normally control the lost limb.
This means that the amputee's own muscle signals are used to control the movement of the
prosthesis.
There are two commonly used myoelectric control systems, including the Otto Bock myoelectric
hand and the Utah arm. The Otto Bock myoelectric hand uses the technique of detecting the fixed
threshold of the integrated rectified surface electromyography. The signals are detected using two
sets of electrodes, and the extension or flexion of the targeted muscle group serves as the on/off
control, causing the hand to open or close, respectively.
The Utah arm, on the other hand, uses myoelectric signals to control the elbow, and the signals are
full wave rectified and differentiated to produce the command signal. The Utah arm has a wrist
rotator and can be combined with different grasping systems, although most artificial hands used
in everyday activities do not have the ability to grasp with five fingers, except in devices that are
mechanically pre-programmed.
An externally controlled elbow-wrist-hand prosthesis was also evaluated, where the position of the
shoulder joint is measured with a potentiometer mounted between the upper arm and trunk. An
important feature of the system is that disabled individuals can learn how to control the prosthesis
within minutes using a trial-and-error procedure.