STV INDUSTRIES,HOSUR SAR CORRECTIVE ACTION REPORT

PART NO : N 20 41406 DATE : 03.11.2022

SL NO DIMENSIONS SAR REPORT ACTUAL CORRECTIVE ACTION TARGET DATE RESBONSIBILITY

A 8.1 +0.1 8.05 O/S IMMEDIATELY DRILL BIT, FEED RATE CHANGED 01.11.2022 SUB_CONTRACTOR

C ø 0.2 0.43 O/S IMMEDIATELY PROGRAM HAS BEEN CHANGED 01.11.2022 SUB_CONTRACTOR

I M28X1P-8G GO NOT ANSWERING INSERT GRADE HAS BEEN CHANGED 01.11.2022 STV

U 2.3 ±0.2 1.90 , 1.88 PROGRAM CORRECTION HAS BEEN DONE 01.11.2022 STV

S1 8.75 ± 0.25 9.08 O/S PROGRAM CORRECTION HAS BEEN DONE 01.11.2022 STV

D2 HARDNESS 20 TO 28 31 HIGH INFORMED TO SUB SUPPLIER HARDENING TEMPERATURE 01.11.2022 SUB_CONTRACTOR


HAS REDUCED

MACHINING STEP MARK OBSERVED UPTO 0.03 MM ON FLY FACE TOOL HAS CHANGED IMMEDIATELY TO AVOID THE
WHEEL CUP SEATING AREA STEP MARK ISSUE 01.11.2022 STV

RUST OBSERVED IN TAPER AREA RUST PREVENTIVE OIL CHANGED IN OUR OILING PROCESS 01.11.2022 STV
GRADE R 823-S

PREPARED BY : A.P BHARATHRAM APPROVED BY : D. PARTHIBAN