*1. Single-dotted lines indicate wiring not supplied with the unit.

*2. Dot-dash lines indicate the control box boundaries.


*3. Refer to the Data book for connecting input/output
4. ELECTRICAL WIRING DIAGRAMS

MEES17K196
signal connectors.
*4. Daisy-chain terminals (TB3) on the outdoor units in the
same refrigerant system together.
*5. Faston terminals have a locking function. 63H1

Make sure the terminals are securely locked in place P

after insertion. Press the tab on the terminals to


removed them. 1 CNSNR 12 456 6
2 FAN Board 5
3 CN81 4
*6. Control box houses high-voltage parts. 4 F121 green CN80 3
5 DC700V 2
Before inspecting the inside of the control box, turn off 4A T 1
4 C151,C152
OFF ON 1 CNDC 6
the power, keep the unit off for at least 10 minutes, and 1 1 3 red 12 654 21 321 4321 5
1 CN82 2
IPM blue 3 CN801 CN61 CN2 CN4 4 M
confirm that the voltage between FT-P and FT-N on CNVDC RSH01/02 4 CPU power red green black CNLVA 3
6 2
7 CN83 1 supply circuit 1 LEV1
SW001 black 2
INV Board has dropped to DC20V or less. U
Fan motor V 4 5 6
MS LED1:Normal operation(Lit)
*7. Difference of appliance (Heat exchanger) 3~ 72C 2 ZNR400
CNINV / Error(Blink) 6 1 CNRYB M
W
1 Control Board CNLVB 43
Model name Appliance LED4:CPU in operation U Power failure
red 2
detection circuit 1 LEV2
P200/P250/P300 *7 do not exist C100
R1,R5 *5 6
P350/P400/P450 *7 exist DCL 5 LED1
black LED3
red 1 2 SV1a 3 CN505 3
3 72C 4 LED2:Normal operation(Lit)
21S4a X06 1
red black 1 OFF ON OFF ON OFF ON CNTYP2
CN43 2 SWU2 SWU1 1 1 1 / Error(Blink) black
6 CN5 21 yellow 1 *7 X05 10's 1's
5 CN4 red 1 3 SC-P1 6
1 SC-P2 CN6 digit digit
4. ELECTRICAL WIRING DIAGRAMS

3 blue 7
CN2 R5 D1 R4 5 SWP1
3 6
*6 LED1:Normal operation(Lit) 5 SV5b CN506 Z25
+ CN1 / Error(Blink) 3 red Unit address CNTYP5 3
R6 P FT-P CN2 10 10 10
1 21S4b setting SET UP(SW6-10) green 1
4 X08 SW4 SW5 SW6
C1 1
Surge C11 Z5 1 N FT-N 1
absorber X07 LED1
+ U - C30,C32, C31,C33, ZNR1 RSH1 6
Noise C34,C36 CNTYP 3 Display Function
DB1 C35,C37 U black CN213 2
Filter + + 1 CN507 setting/ setting t° TH6
IPM SV9 green 1
3 black Function
R30,R32, R31,R33, t° 4
THHS X10 setting t° TH7
F4 R34 R35 1 CN212 3
AC250V DC12V CN51 red 2 TH3
Noise filter t°
6.3A T SC-V 1
SC-L1 1
SC-U SC-W *3 CN990 2
red red 3 t° TH5
green 1
4 Compressor ON/OFF output
Noise filter white white 5 1
Error detection output
black black
CN202 32 2 63LS
SC-L2 red 1 3
PUHY-P200, 250, 300, 350, 400, 450YKA(-BS)

1 black
SC-L3 3 1
CT3 CN110 TB7 Power CN201 2 2 63HS1
L1 L2 L3 N 3 2 1
selecting 3
CN1A CN3 CT12 CT22 1
<Symbol explanation> 3 1 4
green INV Board connector 4 t° TH4
1 CN1B red white black CN211 3
TB21 TB22 TB23 TB24 CN40 green 2
Symbol Explanation F01 t° TH2
AC250V 1234 ON 1
21S4a 4-way valve Cooling/Heating switching L 3.15A T yellow yellow blue red green red
CNPOW CN3K CN3N CN3S CN3D CN62 CN41 CNPS
21S4b Heat exchanger capacity control 3 1 2 1 black 12 321 321 321 321 12 3456 1234 12345
CNAC CNAC2 OFF
63H1 Pressure High pressure protection for the
switch outdoor unit *3
63HS1 Pressure Discharge pressure
TB1
63LS sensor Low pressure L1 L2 L3 N
72C Magnetic relay(inverter main circuit)
red white black CN04 CNIT
C30~C37 Capacitor (inverter main circuit) V 1 3 red 21 1 2 3 4 CN102 red 54321
CT12,22,3 Current sensor(AC) U W CNS2
MS LED1:Power supply to
yellow Indoor/Outdoor
DCL DC reactor 3~ M-NET power transmission line
L Choke coil (for high frequency noise reduction) supply circuit
L1 L2 L3 N Motor TB3 TB7
LEV1 Linear HIC bypass,Controls refrigerant Power Source (Compressor) M1 M2 M1 M2 S
expansion flow in HIC circuit 3N~ TP1 TP2
LEV2 valve Pressure control,Refrigerant flow 50/60Hz
380/400/415V M-NET Board
rate control
R1,5 Resistor For inrush current prevention
RSH01/02,RSH1 For current detection
SV1a Solenoid For opening/closing the bypass
valve circuit under the O/S *4
SV5b Outdoor unit heat exchanger Indoor/Outdoor Central control
capacity control
transmission transmission
cable cable
SV9 For opening/closing the bypass
circuit
TB1 Terminal Power supply
TB3 block Indoor/Outdoor transmission cable
TB7 Central control transmission cable
TH2 Thermistor Subcool bypass outlet
temperature
TH3 Pipe temperature
TH4 Discharge pipe temperature
TH5 ACC inlet pipe temperature
TH6 Subcooled liquid refrigerant
temperature
TH7 OA temperature
THHS IPM temperature
Z25 Function setting connector
Y-Series

57
PUHY-P-Y(S)KA, EP-Y(S)KA