Safety First
• Cut off the power supply before installation and maintenance.
• Drain Pump Assy must be installed at safe area where it is far away from the user.
• Drain Pump Assy must be installed at appointed location.
• All wiring and connections are for installation only.
Screw Cap
Quantity
Quantity Package contents
1 Drain Pump Assy(AC220~240V, 50/60Hz, 400cm3/min)
4 Screw
1 Cap
1 Installation manual
P/No.:3828A20224A
1
How to install
3. Remove the knock-out from the side 4. Assemble the drain pump assy.
panel. - Drive 4 screws to the Side Panel.
5. Connect two lead wires to control box. 6. Close the drainage hole with the provided
(One is for float switch, the other is for cap.
power supply to drain pump.)
2
Attention
Drain Pipe
2. Keep the drain hose downward up
to 1/50~1/100 inclination. MAX 700mm
Prevent any upward flow or
reverse flow in any part.
Drain Pump
Thermal insulator
(Local supply)
3. 5mm or thicker formed thermal Drain pipe
insulator is provided for the drain (Local supply)
pipe. Unit
Elbow
Drain pump
Wall
4. Upward routing is not allowed.
Drain hose
Drainage Hole
3
Wiring Diagram
THERMISTOR
YL
TEMP.
INDOOR DRAIN
GN/YL
MOTOR PUMP
OR
BR
BL
BL
BK
FUSE
250V 8A
1 (L ) 2 (N )
BR
TRIAC
BL
TO OUTDOOR UNIT
COMP
4 WAY PIPE
VENT
RD Drain Pump Assy THERMISTOR
3
BK
4
FLOAT S/W
BL BR
5
GN/YL REMOTE
CONTROL
TERMINAL
BLOCK T/B
A/CL TELECONTROL/ ZONE OPTION
UNIT CENTRAL CONTROL CONTROL
VENTILATOR
Test operation
• Before test operation, be sure all information is understood completely, and follow
the guideline of manual.
• Connect the power and turn on cooling mode.
• After compressor operating, it starts and compressor off, it stops 6 minutes later.
Troubleshowting