REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS & HIGHWAYS

OFFICE OF THE BUILDING OFFICIAL


N 11 38' E 2 N 11 35' E
A-3

1 1' 2 2' 3 4

12010
1000 1000 7590 2410
4090 3500 DISTRICTS | CITY | MUNICIPALITY

4 5 1 LAND USE AND ZONING

5290
7090
LINE AND GRADE

1000 800
A
BUILDING LINE

1400

2400
1000
B ARCHITECTURAL

3500

4500
A PERSPECTIVE

24990

24990
A-1 SCALE NTS

12400
1000

13900
N 77 27' W

S 27 26' E
C
N
2

STRUCTURAL
CK 0

4000

4000
1
W E
LO
16 B

LOT Athens
15 B
LOC
K 02 S A-3
LOT

1
5
D
2 Cana
K 02

1500

1500
LOC

Rome
E

Su
m
ulo
L O T 4B B L O C K 0 5
18 B

1500
SANITARY

ng
Hig
THE SITE
WIDE

hw
LOT

ay
4 LOT 17 BLOCK 02 PHASE 6
10M

TAGAK ST. BANKER VILLAGE,


BRGY. STA. CRUZ, ANTIPOLO CITY
ROAD

5500

3000
LOT d
oa
19 B onR
LOC pti
K 02 sum
As
3
ati
Kalap

First Pacific

1000
Tagak
l a

Leadership
Yak

Academy 3 PROPERTY LINE


2
ELECTRICAL
SIDEWALK

B LOCATION MAP RAMP UP

A-1 SCALE NTS

W
1000 1450 3000 1740 1400 1000
1410 5450 4140 1000
TECHNICAL DESCRIPTION N 11990

N
Marco
s

LINE BEARING DISTANCE


ay

W E
w
gh

S
Hi

Qu
g

irin
MECHANICAL
on

1-2 24.99 m o
ul
m

S
Su

E
2-3 12.00 m S 11 37' W
3-4 24.99 m

4-5 6.98 m C VICINITY MAP D SITE DEVELOPMENT PLAN


A-1 SCALE NTS A-1 SCALE 1:100m
5-1 5.02 m
DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


R. LIWANAG A-1
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 1 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
N 11 38' E 2 N 11 35' E N 11 38' E 2 N 11 35' E N 11 38' E 2 N 11 35' E
A-3 A-3 A-3

1 2 3 4 1 1' 2 2' 3 4 1 1' 2 2' 3 4

12000 12010 12010


2000 3800 3800 2410 2000 3790 3810 2410 2000 7590 2410
1980 900 920 3800 2260 850 680 680 850 2290 3800 3800

4 5 1 4 5 1 4 5 1

5290
7090

9490
9740
DIRTY KITCHEN/

1800
LAUNDRYAREA
FL=+150mm

13990

14180
SINK
BUILDING LINE
A

W
1250

UTILITY ROOM REF K.SINK

FL=+400mm

2600
ROOF LINE

H
KITCHEN
1400

COMMON T&B AREA

T
FL=+400mm
FL=+400mm

B B

CLOSET
CLOSET
MASTER WALK-IN- BEDROOM 1 BEDROOM 2

2020
2480

P
FL=+3600mm FL=+3600mm
T&B CLOSET

3920
FL=+400mm
FL=+400mm

4500
COMMON COMMON

24990

24990

24990

24990
24990

24990

1650

1500
Y
LANAI T&B 1 T&B 2
DINING AREA FL=+150mm
FL=+3600mm 1200 FL=+3600mm
12400
1970

FL=+400mm

A
MASTER'S

780

770
BEDROOM

13900

N 77 27' W

N 77 27' W
N 77 27' W

S 27 26' E

S 27 26' E

S 27 26' E
CLOSET
W
FL=+400mm
C C C
BEDROOM 3 BEDROOM 4 SINK

1530

1530
1530

1600
FL=+3600mm FL=+3600mm

CLOSET

11500
L
11250
Y

L
GYM

4000

3600
3600
LIVING AREA CLOSET FL=+6800mm
A

DN
FL=+400mm

A
2070

2080
2070

2000
9 10 11 12 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16
W

7000
H
A-3 UP A-3 UP A-3
1 8 7 6 5 4 3 2 1 1 8 7 6 5 4 3 2 1
BEDROOM 5 1 8 7 6 5 4 3 2 1

D D FL=+3600mm D
H

1700

1700
1700

1700

T&B

1500
T

FL=+3600mm ROOF LINE


ROOF DECK

3190
FL=+6700mm
E E
A

1500

1500
1500
1500

PORCH BALCONY
P

FL=+150mm FL=+3500mm

CARPORT
5500

3000

3000

3010
4000

4000
1000

1000
1000

3 PROPERTY LINE
2 3 PROPERTY LINE
2 3 PROPERTY LINE
2

SIDEWALK SIDEWALK SIDEWALK

RAMP UP RAMP UP RAMP UP

2400 1300 2050 1840 560 2400 1300 3890 3710


2410 3900 3690 2010 2410 4450 3150 2000 2410 7600 2000
12000 12000 12000

W
S 11 37' W S 11 37' W S 11 37' W

N
S
A GROUND FLOOR PLAN B SECOND FLOOR PLAN C THIRD FLOOR PLAN
A-2 SCALE 1:100m A-2 SCALE 1:100m A-2 SCALE 1:100m

E
DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


R. LIWANAG A-2
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 2 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 1' 2 2' 3 4 E D C B A
ROOF APEX-2 ROOF APEX-2

950

950
TOP OF ROOFBEAM W TOP OF ROOFBEAM

300

300
5 D W
3F FINISH CEILING LINE 5 3F FINISH CEILING LINE 6

1750

1750
2700

2700
2400

2400
ROOF APEX-2 ROOF APEX-2

950

950
3F FINISH FLR.LINE 3F FINISH FLR.LINE

500

500
W
5 W W
2F FINISH CEILING LINE W D 8 2F FINISH CEILING LINE 8 W W W
2 4 3 3 2

2450

2450
10450

10450
3200

3200
2700

2700
ROOF APEX-1 ROOF APEX-1

750

750
2F FINISH FLR.LINE 2F FINISH FLR.LINE

500

500
W W
GF FINISH CEILING LINE 9 GF FINISH CEILING LINE 9 W D
D 4
3 4
3200

3200
3600

3600
2700

2700
GF FINISH FLR.LINE GF FINISH FLR.LINE
400

400
NGL NGL

A FRONT ELEVATION B RIGHT SIDE ELEVATION


A-3 SCALE 1:100m A-3 SCALE 1:100m

4 3 2' 2 1' 1 A B C D E
ROOF APEX-2 ROOF APEX-2
950

950
TOP OF ROOFBEAM TOP OF ROOFBEAM W W
300

300
W W 3 5
3F FINISH CEILING LINE 7 7 3F FINISH CEILING LINE
1750

1750
2700

2700
2400

2400
ROOF APEX-2 ROOF APEX-2
950

950
3F FINISH FLR.LINE 3F FINISH FLR.LINE
500

500
W
5
2F FINISH CEILING LINE W W 2F FINISH CEILING LINE W W W
3 3 3 2 3
2450

2450
10450

10450
3200

3200
2700

2700
ROOF APEX-1 ROOF APEX-1
750

750
2F FINISH FLR.LINE 2F FINISH FLR.LINE
500

500
GF FINISH CEILING LINE D GF FINISH CEILING LINE W W W W W
2 2 2 2 3 3
W
1
3200

3200
3600

3600
2700

2700
GF FINISH FLR.LINE GF FINISH FLR.LINE
400

400
NGL NGL

C REAR ELEVATION D LEFT SIDE ELEVATION


A-3 SCALE 1:100m A-3 SCALE 1:100m

1 1' 2 2' 3 4 E D C B A
ROOF APEX-2 ROOF APEX-2
950

950
TOP OF ROOFBEAM TOP OF ROOFBEAM
SEE ROOF DETAILS SEE ROOF DETAILS
300

300
3F FINISH CEILING LINE 3F FINISH CEILING LINE
1750

1750
2700

2700
2400

2400
W W
ROOF APEX-2 7 GYM 7 ROOF APEX-2 GYM
950

950
3F FINISH FLR.LINE 3F FINISH FLR.LINE
SEE ROOF DETAILS
500

500
D
2F FINISH CEILING LINE 2F FINISH CEILING LINE D
2 1 BEDROOM 2
2450

2450
10450

10450
3200

3200
2700

2700
BEDROOM 5
ROOF APEX-1 ROOF APEX-1
750

750 H A L L W A Y
2F FINISH FLR.LINE STAIRS 2F FINISH FLR.LINE SEE ROOF DETAILS
STAIRS
500

500
GF FINISH CEILING LINE GF FINISH CEILING LINE D D D
2 1 2
W
1
LIVING AREA DINING KITCHEN
3200

3200
3600

3600
2700

KITCHEN
2700

AREA

GF FINISH FLR.LINE GF FINISH FLR.LINE


400

400

NGL NGL

1 CROSS SECTION 2 LONGITUDINAL SECTION


A-3 SCALE 1:100m A-3 SCALE 1:100m

DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


M.ESPIRITU A-3
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 3 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
DOORS AND SCHEDULE STAIR DETAILS CEILING DESIGN SPECIFICATION
3100 3100
1200 1200 1000 2100 1000 2100
700 800 1000 200 600 600
200
BASE ON THE
7 EQUAL THREADS 7 EQUAL THREADS SIZE OF BEAM
300mm EACH 300mm EACH

SLAB

9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 BEAM

8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
LED LIGHT

7 EQUAL THREADS 7 EQUAL THREADS


300mm EACH 300mm EACH METAL FURRING WITH
SMART BOARD CEILING
1000 2100 1000 2100 (RIVET CONNECTION)
3100 3100

D TYPE LOCATION/S D TYPE LOCATION/S D TYPE LOCATION/S D TYPE LOCATION/S


PLAN PLAN
1 WOOD MASTER'S T&B 2 WOOD MASTER'S BEDROOM 3 WOOD PANEL DOOR ENTRANCE 4 GLASS BALCONY SCALE 1:75 SCALE 1:75
PANEL DOOR 1F T&B PANEL DOOR DIRTY KITCHEN (SWING TYPE) PANEL DOOR

5 SET
(SWING TYPE) 2F T&b 1
2F T&B 2 7 SET
(SWING TYPE) BEDRM 1,2,3,4&5
1 SET 1 SET
(SWING TYPE) 1 COVE CEILING DETAIL
REQUIRED BEDROOM 5 T&B REQUIRED REQUIRED REQUIRED (OFFSET @ 500mm FROM WALL)
16

15

14

13
2200 3000 12

300 800 800 300 750 750 750 750 11

10

7 CEILING LINE 200


6
AT THE BOTTOM OF BEAM BASE ON THE
5
SIZE OF BEAM
4

F F 2
SLAB
1

16

15
BEAM OPEN
14

13

12

11

10

D TYPE LOCATION/S D TYPE LOCATION/S 5


METAL FURRING WITH
4
SMART BOARD CEILING
(RIVET CONNECTION)
5 GLASS DINING AREA 6 GLASS BALCONY
3

SLIDING DOOR SLIDING DOOR 1

(SLIDING TYPE) (SLIDING TYPE)


1 SET 1 SET
REQUIRED REQUIRED

ELEVATION
400 SCALE 1:75 2 FLAT CEILING DETAIL
1200
600 600 600 600
1200 F
600 600
SPOT DETAIL OF STAIR
F

F F
2ND FLR. LV.

TYPE GLAZING LOCATION TYPE GLAZING LOCATION TYPE GLAZING LOCATION TYPE GLAZING LOCATION TYPE GLAZING LOCATION
W W W W W
EARTH FILL COMPACTED
1 GLASS DOORS 6mm THICK KITCHEN 2 GLASS DOORS 6mm THICK MASTER'S T&B 3 GLASS DOORS 6mm THICK MASTERS BEDRM 4 GLASS DOORS 6mm THICK LIVING AREA 5 GLASS DOORS 6mm THICK STAIRS
(SLIDING TYPE) ORDINARY AREA (SLIDING TYPE) ORDINARY 1F T&B (SLIDING TYPE) ORDINARY BEDRM 1,2,3, (AWNING TYPE) ORDINARY (FIXED TYPE) ORDINARY
GLASS GLASS 2F T&b 1 GLASS 4&5 GLASS GLASS @ 0.30 m. O.C.
ALUMINUM ALUMINUM 2F T&B 2 ALUMINUM GYM ALUMINUM ALUMINUM
1 SET FRAME 6 SET FRAME BEDROOM 5 9 SET FRAME 1 SET FRAME 4 SET FRAME
REQUIRED REQUIRED
T&B
REQUIRED REQUIRED REQUIRED 6 EQUAL SPACES O. C.
STORAGE

SCALE : NTS

1200 2800 1500


600 600 950 910 950 1000 500 1000 1000 1500

F F GATE ELEVATION
F F
SCALE : 1:50m
F F 11900
200 3000 3000 1000 1000 1000 2700
F F
F F
F F

TYPE GLAZING LOCATION TYPE GLAZING LOCATION TYPE GLAZING LOCATION TYPE GLAZING LOCATION
W W W W
6 GLASS DOORS 6mm THICK GYM 7 GLASS DOORS 6mm THICK GYM 8 GLASS DOORS 6mm THICK BEDROOM 5 9 GLASS DOORS 6mm THICK LIVING AREA
(SLIDING WITH FIXED ORDINARY (SLIDING TYPE) ORDINARY (SLIDING W/ FIXED ORDINARY (FIXED TYPE) ORDINARY
TYPE) GLASS GLASS TYPE) GLASS GLASS
ALUMINUM ALUMINUM
1 SET ALUMINUM
FRAME
2 SET FRAME 1 SET ALUMINUM
FRAME
1 SET FRAME VEHICULAR GATE PEDESTRIAN GATE CERAMIC WALL TILES
REQUIRED REQUIRED REQUIRED REQUIRED

DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


M.ESPIRITU A-4
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 4 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
GUTTER
N 11 38' E N 11 35' E
LONG SPAN ROOF
12000 12010 12010
2000 3800 3800 2410 2000 3790 3810 2410 2000 7590 2410 1 1' 2 2' 4' 4
1980 900 920 3800 2260 850 680 680 850 2290 3800 3800

12000
1000 1000 7590 1000 1410
4090 3500

4 5 1

5270
6090

1000 810
A

1000
BUILDING LINE

1400

1400
1000

1000
B

3500

3500
24990

24990
12900
1000

1000
13900
N 77 27' W

S 27 26' E
C

4000

4000
D

1000

1000
3 2 3 2 3 2

2000
2400 1300 2050 1840 560 2400 1300 3890 3710
2410 3900 3690 2010 2410 4450 3150 2000 2410 7600 2000
12000 12000 12000

6000

3000
1000
GROUND FLOOR SECOND FLOOR THIRD FLOOR
3 PROPERTY LINE
2
A REFLECTED CEILING PLAN B REFLECTED CEILING PLAN C REFLECTED CEILING PLAN
SIDEWALK
A-5 SCALE 1:120m A-5 SCALE 1:120m A-5 SCALE 1:120m
RAMP UP

5450 1740 1400 1000


1410 5450 4140 1000
11990
LEGEND

W
DROPLIGHT

N
CENTER LIGHT
S 11 37' W
LED STRIP

S
LIGHT D ROOF PLAN

E
PINLIGHT CEILING LINE A-5 SCALE 1:100m

DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


M.ESPIRITU A-5
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 5 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
.20 SLAB DETAIL
STRUCTURAL STEEL CONSTRUCTION NOTES :

.30
L/4 L/4
ALL GENERAL MILL SECTIONS, BUILT UP PLATE SECTIONS SHALL BE DESIGNED IN
SCHEDULE OF REINFORCING BARS ACCORDANCE WITH AISC'S LATEST SPECIFICATION FOR THE DESIGN, FABRICATION AND
ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. @ SUPPORT

B-1
DIAMETERS OF BARS GRADE(fy) ASTM

A615/A615M DESIGN LOADS FOR BUILDINGS SHALL MEET REQUIRED STRUCTURAL DESIGN CRITERIA .20
GRADE 33 (3,000psi) DEFORMED

GRADE 40 (3,000psi)
A615/A615M STEEL PLATES, SHAPES,BARS AND METAL FABRICATION: ASTM A-36. L/5 L/5
(DEFORMED)

.30
BARS SHALL BE CLEAN OF RUST, GREASE OR OTHERS MATERIALS LIKELY TO IMPAIR
@ MID-SPAN
BOND. ALL REINFORCING BARS BENDS SHALL BE MADE COLD. ELEVATION
ELECTRODES FOR WELDING: ASTM A233 E_70XX SERIES; COMPLY WITH AWS D1.1 CODE
ALL GRADE 60 REINFORCING STEEL SHALL BE CLEARLY MARKED TO REQUIREMENTS.
DIFFERENTIATE THEM FROM GRADE 40 REINF. STEEL CONCURRENTLY ON SITE.
IN GENERAL, BARS SPLICES SHALL BE MADE AT POINTS OF MINIMUM STREE. FLAME CUTTING AND WELDING SHALL BE DONE. IN ACCORDANCE WITH LATEST
SPLICES SHALL BE SECURELY WIRED TOGETHER. STAGGER SPLICES AT LEAST "STANDARD CODE FOR WELDING IN BUILDING CONSTRUCTION" OF THE AMERICAN .15
600MM. WHENVER POSIBBLE IN BEAM BEAMS AND SLABS SPLICE TOP BARS AT WELDING SOCIETY.
200 200
MIDSPAN AND BOTTOM BAR NEAR SUPPORT. SPLICE REINFORCEMENT SHALL BE

GROUND FLOOR - 2ND FLR


ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS AND SHALL BE PROPERLY

.20
MADE ONLY AS REQUIRED OR PERMITTED ON DESIGN DRAWINGS OR AS ALLOWED & 2-12 MM SECONDARY
BACK-CHIPPED OR GOUGED. BACK-PLATES SHALL BE PROVIDE AS REQUIRED. BARS W/ 10 MM LATERAL SIDE REBARS W/ 10 MM LATERAL

3RD FLR - ROOF BEAM


C1
BE MADE ONLY AS REQUIRED OR PERMITTED ON DESIGN DRAWINGS OR AS

C1, F1

400
TIES 4@.05, 4@.10, 3@.15,

300
TIES 4@.05, 4@.10, 3@.15,
ALLOWED BY THE ACI CODE OR AS AUTHORIZED BY THE ENGINEER. @ SUPPORT THE REST @.20 M THE REST @.20 M
APPLY TT-P-645 SHOP PAINT FOR ALL FABRICATION.
BARS NOTE AS "CONT" SHALL HAVE A MINIMUN SPLICE LENGTH OF 42 BAR ON CENTER SPACINGS ON CENTER SPACINGS

RB-1
SHOP PAINTING FOR STRUCTURAL STEEL SHALL BE RUST INHIBITIVE PRIMER WITH
MINIMUM D.F.T. OF.
.15 200 200
REINFORCING SHALL BE SPLICED ONLY AS INDICATED ON THE DRAWINGS.
MINIMUM CONCRETE COVER FOR REINFORCING BARS SHALL BE: TOUCH-UP PAINTINGS: APPLY PAINT TO EXPOSED AREAS IN MANNER SATISFACTORY TO S1 SUPPORT MIDSPAN SUPPORT

2ND FLR - 3RD FLR


THE ENGINEER WITH SAME MATERIALS AS SHOP PAINT.
& 2-12 MM SECONDARY 100mm THK
BARS W/ 10 MM LATERAL SIDE REBARS W/ 10 MM LATERAL

.20
A. SHORT SPAN

C1, F1

P1
400
TIES 4@.05, 4@.10, 3@.15,

300
ITEM COVER TIES 4@.05, 4@.10, 3@.15, MIDDLE STRIP 200mm 200mm 200mm
COMPLY WITH AISC CODE AND SPECIFICATION FOR BEARING, ADEQUACY OF THE REST @.20 M THE REST @.20 M
ON CENTER SPACINGS COLUMN STRIP 200mm 200mm 200mm
TEMPORARY CONNECTIONS AND ALIGNMENT. @ MID-SPAN ON CENTER SPACINGS
CONCRETE CAST AGAINST EARTH 75 MM B. LONG SPAN
MIDDLE STRIP 200mm 200mm 200mm
EXPOSED TO EXTERIOR OR WEATHER 38 MM CONTRACTOR SHALL FURNISH COMPLETE ERECTION DRAWINGS FOR THE PROSPER COLUMN STRIP 200mm 200mm 200mm
IDENTIFICATION AND ASSEMBLY OF ALL BULDING COMPONENTS. THESE DRAWINGS WILL
FORMED SURFACE BELOW GRADE 50 MM SHOW ANCHOR BOLT SETTINGS, PRIMARY SECONDARY, AND ROOF FRAMING, AND
NECESSARY INSTALLATION DETAILS. SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE SIZE BAR
MARK @ SUPPORTS @ MIDSPAN WB DIA STIRRUPS SPACING
SLAB ON GRADE 50 MM FABRICATION. B D DIA.
mm mm mm TB-1 TB-2 BB-1 BB-2 TB-1 TB-2 BB-1 BB-2
COLUMNS AND BEAMS 38 MM
APPLICATION OF FIRE PROFFING SYSTEM IS REQUIRED FOR ALL STRUCTURAL STEEL
MEMBERS. PROVIDE 2 HOUR MINIMUM FIRE RATING. REFER TO ARCHITECTURAL AND B-1 200 400 16 3 2 2 3 1 @ 50, 10 @ 100, REST @ 200
STRUCTURAL SLABS TOP & BOT. (INTERIOR) 25 MM
MECHANICAL PLANS FOR ADDITIONAL FIRE PROOFING REQUIREMENTS.
RB-1 200 300 12 2 2 2 2 1 @ 50, 10 @ 100, REST @ 200
ANY WELDING TO BE PERFORMED MUST HAVE PRIOR WRITTEN APPROVAL OF THE 500 200 500 800 200
ENGINEERS. 500 200 500 SECOND FINISH FLOOR LINE

WELDING OF REINFORCING STEEL IS NOT PERMITED UNLESS OTHERWISE SHOWN

400

300
ON THE DRAWINGS OF REINFORCING STEEL SHALL CONFORM TO AWS
400

10 MM ADDITIONAL
D1.4-79"AWS STRUCTURAL WELDING CODE - REINFORCING STEEL" OF THE 12 MM BARS
BARS

1200

1000
400

400
AMERICAN WELDING SOCIETY REINFORCING STEEL WHICH IS WELDED SHALL
AS SHOWN
1200
400

0.30 +- .15

CONFORM TO ASTM A 706. REINFORCING STEEL NOT CONFORMING TO ASTM A 10 MM TIES


@ EVERY .30 M OC
16 MM BARS
706 MAY BE USED IF MATERIAL PROPERTIES OF THE REINFORCING STEEL

400

300
@ EVERY .30 M OC
400

FIN. GROUND FLR. LINE

CONFORM TO AWS D1.4-79.


PLAN PLAN 3-12 MM LONG BARS

WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A-185. WELDED WIRE PLAN 1200
1200 1000 TIE WITH 10 MM BARS
@ EVERY .30 M OC

FABRIC IN SUSPENDED SLABS SHALL HAVE FY = 60 SI. LAP 152 MM. MINIMUM SPOT DETAIL 1
6-16 MM VERTICAL BARS
OR ONE FULL MESS WHICHEVER IS GREATER FOR SLABS ON GRADE. 6-16 MM VERTICAL BARS
WITH 10 MM LATERAL TIES
WITH 10 MM LATERAL TIES
3@.05, 4@.10, 3@.15, REST
SHOP DRAWINGS: THE CONTRACTOR SHALL SUBMIT DRAWINGS FOR 3@.05, 4@.10, 3@.15, REST
@.20 M ON CENTER SPACINGS
@.20 M ON CENTER SPACINGS
NAT GRADE LINE NAT GRADE LINE 0.114 M. O.C.
REINFORCING STEEL PREPARED IN ACCORDANCE WITH ACI 315. INDICATE NAT GRADE LINE NAT GRADE LINE
SECOND FLR. LN.

BENDING DIAGRAM, ASSEMBLY DIAGRAM, SPLICING AND LAPS OF RODS AND 8-16 MM BASE BARS
SHAPES DIMENSION AND DETAILS FOR REINFORCING BARS. 10-16 MM BASE BARS @ EQUAL SPACINGS BW

1000

1000
1550

@ EQUAL SPACINGS BW
ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS ARE TO BE SECURELY

1200

1200
1750

0.30

6-16 MM BASE BARS


TIED IN PLACE BEFORE CONCRETE IS POURED. @ EQUAL SPACINGS BW

200

200
LANDING
200

NOTES:
SPOT DETAIL 2
SECTION SECTION
1. ON PLACEMENT OF BARS FOR BOTH ONE-WAY AND TWO-WAY SLAB. C1, F1 C1, F2
1.1 BOTTOM BARS ALONG SHORT SPAN SHALL BELOW THOSE ALONG LONG
SPAN.
1.2 TOPS BARS ALONG SHORT SPAN SHALL BE ABOVE THOSE ALONG LONG A DETAIL OF COLUMN AND FOOTING B DETAIL OF FOOTING AND TIE BEAM C DETAIL OF STAIR
SPAN. S-1 NTS S-1 SCALE NTS S-1 SCALE NTS
1.3 FOR TWO ADJACENT SLAB OF DIFF.
DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


R. LIWANAG S-1
CHECKED BY:
198 LIGASONG STREET BARANGAY LA MESA CALAMBA CITY LOCATION: AS SHOWN 1 4
EMAIL: novconph@gmail.com MR. JOSE ABENIR
Contact: 09472436027/09776724347 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT: LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.:
BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 2 3 4 1 1' 2 2' 3 4 1 2 2' 4

12010 12010 12010


2000 7590 2410 2000 7590 2410 2000 7590 2410
3800 2500 1300 3800 2500 1300 3800 670 3120

4 5 1 4 5 1 4 5 1

7090
7090

7290
7290

9490
9730
C1F1 SOF
C1F1 C1F1
WF1 WF1
BUILDING LINE
A
RB RB
SOF

2600

2200
2650

2400
RB RB RB
SOF
C1F1 C1F1
SOF SOF
B B B1 B1 RB RB

2300
C1F1 B1 S1 B1 S1 B1 RB RB RB
SOF SOF
B1 B1

4700
4500
4500

4460
4450

WF1
WF1

RB RB

24990

24990

24990

24990
24990

24990

10700
SOF

2400
SOF
12200

B1 S1 B1 S1 B1 RB RB RB
C1F1

8290
C1F1 C1F1

13900
13700
100mm THK. SLAB
SOF B1 B1
C ON FILL ON 50mm
C C

9560
WELL COMPACTED GRAVEL B1 B1

1500
B1 S1 B1 S1 B1 B1 S1 B1 S1 B1

B1 B1 B1 B1

3600
3600

3600
3600

3800
WF1
WF1

B1

2090
STAIRWELL SOF STAIRWELL S1 B1 B1
STAIRWELL B1 S1
C1F1 C1F1 C1F1

SOF D
B1
D B1
D

1500
1500

1600
1600

WF1
SOF B1 S1 B1 S1 B1
ROOF LINE
B1 B1
E E

1600
1600

C1F1 S1
SOF C1F1 B2 B2
B2
SOF

7210

7000
5700
5700

3000

3000
SOF

1000
1000

3 PROPERTY LINE
2 3 PROPERTY LINE
2 3 PROPERTY LINE
2

SIDEWALK SIDEWALK SIDEWALK

RAMP UP RAMP UP RAMP UP

4990 2300 1300 1000 3370 1000 1820 1300 1000 3370 4020 1100
1410 7300 2300 1000 2520 4370 4120 1000 2520 8490 1000
12000 12000 12000

S GROUND FLOOR FOUNDATION PLAN S SECOND FLOOR FRAMING PLAN S THIRD FLOOR FRAMING PLAN
S-1 SCALE 1:100m S-2 SCALE 1:100m S-3 SCALE 1:100m

DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


R. LIWANAG S-2
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 2 3
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
GUTTER GUTTER

CEE PURLINS @ EVERY .60M O.C SPACING LONG SPAN ROOF

1 2 2' 4 1 1' 2 2' 3 4 1 1' 2 2' 3 4

12010 12010 12010


2000 7590 2410 1000 9590 1410 1000 1000 7590 1000 1420
3800 670 3120 1000 800 1200 1200 1200 1200 1200 800 1000 4090 3500

BUILDING LINE BUILDING LINE


A A

B B

C RB RB C C

RB RB RB

RB RB

RB RB RB

RB RB
D D D

ROOF LINE

E E

PROPERTY LINE PROPERTY LINE PROPERTY LINE

SIDEWALK SIDEWALK SIDEWALK

RAMP UP RAMP UP RAMP UP

3370 320 3700 1100 1000 7590 1000 5450 1740 1400 1000
2520 8490 1000 1400 9590 1000 1410 7190 2400 1000
12000 12000 12000

S ROOF BEAM FRAMING PLAN S ROOF TRUSS PLAN S ROOF PLAN


S-3 SCALE 1:125m S-3 SCALE 1:125m S-3 SCALE 1:125m

VARIES

2 's 2 12 X 2 X 14 ANGLE BAR


KING POST

2 X 3 CEE PURLINS WITH 1 12 X1 12 X 16


3

ANGLE BAR CONNECTOR @ EVERY


.60 M OC SPACINGS LONG SPAN ROOF

2 's 2 21 X 2 X 41 ANGLE
BAR TOP CHORD

1000 1000 1000 1000

4000
2 's 2 12 X 2 X 14 ANGLE BAR
BOTTOM CHORD

HT-1 HT-2 HT-3


NOTE: VERIFY ON SITE NOTE: VERIFY ON SITE NOTE: VERIFY ON SITE NOTE: VERIFY ON SITE
DESIGNED BY:
ARCHITECT: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


R. LIWANAG S-3
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 3 3
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
ELECTRICAL NOTES: LEGEND: LOAD SCHEDULE AND COMPUTATION
SIZE OF BREAKER NO.OF OUTLETS LOAD IN SIZE OF WIRE
CKT OTHERS CONDUIT
NO. GROUND SIZE
ALL ELECTRICAL WORKS HEREIN SHALL COMPLY WITH THE PERTINENT PROVISIONS OF THE LATEST AT AF P KAIC LTG CO PHASE WIRE WIRE
CEILING LIGHT RANGE OUTLET RATING AMP
APPROVED EDITION OF THE PHILIPPINE ELECTRICAL CODE, WITH THE RULES AND REGULATIONS OF CL RANGE PANEL : LP/PP PVC
1 15 50 2 10 20 LIGHTING OUTLETS @ 50w 1000 W 4.35 2 - 3.5 1 - 3.5 20
THE NATIONAL AND LOCAL AUTHORITIES CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS PIN LIGHT
PL REFRIGERATOR OUTLET 2 15 50 2 10 20 LIGHTING OUTLETS @ 50w 1000 W 4.35 2 - 3.5 1 - 3.5 20
AND ORDINANCES OF THE UTILITY COMPANY'S CONCERED. REFRIGERATOR
3 15 50 2 10 17 LIGHTING OUTLETS @ 50w 850 W 3.70 2 - 3.5 1 - 3.5 20
DP
DROP LIGHT AIRCONDITIONING OUTLET 4 15 50 2 10 20 LIGHTING OUTLETS @ 50w 1000 W 4.35 2 - 3.5 1 - 3.5 20
ACU
THERE SHALL BE ONLY ONE SERVICE DROP INTO THE BUILDING AND IT SHALL BE 220 / 230 VOLTS, 5 15 50 2 10 20 LIGHTING OUTLETS @ 50w 1000 W 4.35 2 - 3.5 1 - 3.5 20
6 15 50 2 10 20 LIGHTING OUTLETS @ 50w 1000 W 4.35 2 - 3.5 1 - 3.5 20
WALL BRACKET LAMP CIRCUIT BREAKER
WL 7 15 50 2 10 2 LIGHTING OUTLETS @ 50w 100 W 0.43 2 - 3.5 1 - 3.5 20
8 20 50 2 10 7 C.O. (2 - GANG PER OUTLET) 2520 W 10.96 2 - 3.5 1 - 3.5 20
STRIP LIGHT INSIDE 2 CIRCUIT HOMERUN
UNLESS OTHERWISE SPECIFIED ON PLANS, OTHER WIRINGS SHALL BE INSTALLED IN STANDARD 9 20 50 2 10 8 C.O. (2 - GANG PER OUTLET) 2880 W 12.52 2 - 3.5 1 - 3.5 20
10 20 50 2 10 8 C.O. (2 - GANG PER OUTLET) 2880 W 12.52 2 - 3.5 1 - 3.5 20
POLYVINYL CHLORIDE (PVC) RIGID CONDUITS, RUN EMBENDDED INSIDE HOLLOW BLOCKS,
SWITCH RUN GROUND WIRE 11 20 50 2 10 8 C.O. (2 - GANG PER OUTLET) 2880 W 12.52 2 - 3.5 1 - 3.5 20
CONCRETE STRUCTURES AND INSIDE THE CEILING SURFACES. 12 20 50 2 10 4 C.O. (2 - GANG PER OUTLET) 1440 W 6.26 2 - 3.5 1 - 3.5 20
COND. RUN IN PVC EXPOSED 13 20 50 2 10 4 C.O. (2 - GANG PER OUTLET) 1440 W 6.26 2 - 3.5 1 - 3.5 20
SERVICE ENTRANCE ELECTRIC RANGE
INTERMEDIATE METALLIC TUBING (IMT) UNLESS OTHERWISE INDICATED. 14 30 50 2 10 5000 W 21.74 2 - 5.5 1 - 5.5 20
15 30 50 2 10 REFRIGERATOR 750 W 3.26 2 - 5.5 1 - 5.5 20
COND. RUN IN PVC EMBEDDED M KILOWATT HOUR METER 16 30 50 2 10 ACU (1.5HP) 1120 W 4.87 2 - 5.5 1 - 5.5 20
WHENEVER REQUIRED AND NECESSARY PULL BOX OF PROPER SIZE SHALL BE INSTALLED AT 17 30 50 2 10 ACU (1.5HP) 1120 W 4.87 2 - 5.5 1 - 5.5 20
CONVENINT AND INCONSPICIOUS LOCATION TO FACILITATE WIRE FULLING EVEN THIS ITEM ARE S ONE WAY SWITCH
TV
TV CABLE 18 30 50 2 10 ACU (1.5HP) 1120 W 4.87 2 - 5.5 1 - 5.5 20
19 30 50 2 10 ACU (1.5HP) 1120 W 4.87 2 - 5.5 1 - 5.5 20
NOT SHOWN IN PLANS. 20 30 50 2 10 ACU (1.5HP) 1120 W 4.87 2 - 5.5 1 - 5.5 20
Sabc SWITCH A,B,C TELEPHONE 21 30 50 2 10 ACU (1.5HP) 1120 W 4.87 2 - 5.5 1 - 5.5 20
T-P
ALL MATERIALS TO BE USED SHALL BE NEW AND OF APPROVED TYPE AND QUALITY, INSTALLED IN 22 30 50 2 10 WATER HEATER 3500 W 15.22 2 - 5.5 1 - 5.5 20
EMERGENCY LIGHT
APPLICATION FOR WHICH THEY ARE INTENDED. LIGHT CONTROL SWITCHES SHALL BE INSTALLED AT A S 3W TWO WAY SWITCH E-L 23 30 50 2 10 WATER HEATER 3500 W 15.22 2 - 5.5 1 - 5.5 20
24 30 50 2 10 WATER HEATER 3500 W 15.22 2 - 5.5 1 - 5.5 20
HEIGHT OF 1.40 M. ABOVE FLOOR AT CENTER, AND ITS INTENDENGEABLE TYPE, RATED 15 AMPS CONVENIENCE OUTLET 25 30 50 2 10 WATER HEATER 3500 W 15.22 2 - 5.5 1 - 5.5 20
CO CCTV CCTV CAMERA
120-277 VOLTS AND SHALL NOT CARRY A LOAD OF MORE THAN COVENIENCE OUTLETS SHALL BE 26 SPARE

DUPLEX, RATED 15 AMPS, 250 VOLTS AND INSTALLED AT A HEIGHT OF 0.30 M. ABOVE FLOOR AT WEATHER PROOF CO
27 SPARE
WCO CEF CEILING EXHAUST FAN 28 SPARE
CENTER.
TOTAL CONNECTED LOAD 46,460 W 202.02
WH WATER HEATER OUTLET PANEL BOARD
ALL WORKSAND INSTALLATION SHALL BE DONE NEATLY IN A WORKMANLIKE MANNER AND SHALL COMPUTATIONS : FULL LOAD CIRCUIT = 172.80 AMPS @ 80% D.F. + 8 (6) + 8 (0.25) = 188.24 AMPS
BE UNDER THE DIRECT SUPERVISION OF A DULY LICENSED PROFESSIONAL ELECTRICAL ENGINEER. MAIN BREAKER : 175 AT 225 AF 2P 230V 60 Hz

3 - WIRES SE CABLE,
230v, 60hz, AC
POWER SERVICE ENTRANCE

"LP/PP" MAIN CB
175AT/225AF
2P 230V

15 AT 15 AT
1 2 3 - WIRES SE CABLE, MAIN PANEL
15 AT 15 AT 230v, 60hz, AC BOARD
CONCRETE PEDESTAL ECB
3 4 POWER SERVICE ENTRANCE
15 AT 15 AT POLE MAIN CIRCUIT BREAKER
175 AT, 225 AF 2P 230V 60 Hz
5 6
15 AT 20 AT
7 8 MDP
20 AT 20 AT
THE SITE
LOT 17 BLOCK 02 PHASE 6
TAGAK ST. BANKER VILLAGE,
9 10 BRGY. STA. CRUZ, ANTIPOLO CITY

20 AT 20 AT
11 12
20 AT 30 AT
13 14
30 AT 30 AT KW/HR
15 16
30 AT 30 AT
17 18
30 AT 30 AT
19 20
GROUND WIRE
30 AT 30 AT
21 22
30 AT 30 AT
23 24
30 AT SPARE
25 26
SPARE SPARE
27 28

GROUND WIRE

A DETAILS OF PANEL BOARD B RISER DIAGRAM C VICINITY MAP


E-1 SCALE: NTS E-1 SCALE: NTS E-1 SCALE: NTS

DESIGNED BY:
PROFESSIONAL ELECTRICAL ENGINEER: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


H. AQUINO E-1
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 1 4
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 1' 2 3 4 1 1' 2 3 4 1 1' 2 3 4

12010 12010 12010

2000 2880 600 4120 2420 2000 2270 850 670 680 840 2270 2420 2000 2270 850 670 680 840 2270 2420

4 5 1 4 5 1 4 5 1
7090

7090

9490

9490

9490

9490
A A A
1250

2750
1500

3
2 1
B B B

2280

2300

2280

2300
2380

2380
2
5
24980

24990

24990

24990

24990

24990
1620

1620
1620

1620
4
3500

3500
C C C

2320

2300

2320

2300
6 7
2170

2180

2180

2180
D D D
1600

1600

1600

1600
E E E

9280

9280
5500

5500

5500

5500
3 2 3 2 3 2
3 - WIRES SE CABLE,
230v, 60hz, AC SIDEWALK SIDEWALK SIDEWALK

POWER SERVICE ENTRANCE RAMP UP RAMP UP RAMP UP


2410 3470 520 3600 2000 2410 2050 2430 3120 2000 2410 2050 2430 3120 2000

12000 12000 12000

GROUND FLOOR SECOND FLOOR THIRD FLOOR

A LIGHTING LAYOUT B LIGHTING LAYOUT C LIGHTING LAYOUT


E-2 SCALE: 1:100 m E-2 SCALE: 1:100 m E-2 SCALE: 1:100 m

DESIGNED BY:
PROFESSIONAL ELECTRICAL ENGINEER: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


H.M. AQUINO E-2
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 2 4
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 1' 2 3 4 1 1' 2 3 4 1 1' 2 3 4

12010 12010 12010

2000 2880 600 4120 2420 2000 2270 850 670 680 840 2270 2420 2000 2270 850 670 680 840 2270 2420

4 5 1 4 5 1 4 5 1
7090

7090

9490

9490

9490

9490
w s s t
A A A
Sv
1250

S rsw
v v r

2750
Sa
1500

o q
a r q t t w w
a t
w
B B s s v v
B
p p

2280

2300

2280

2300
d b r u
2380

2380
S cd n n
St S rst S uvw
S opq s s v v o
c z n n
3W
24980

24990

24990
24990

24990

24990
S cd S xy

1620
m

1620
1620

1620
S zb c
p q x y
k k S pq

S mni d h g h g
3500

3500 m m j j
l j o
C C n n C

2320

2300

2320

2300
f f So b b d d
S jkl l S lmn i
c S ijk
k k
m m 3W j j
S cd e
i k
e d a c
d y
3W
S xy h h g h

2180
2170

2180

2180
x c S ghl
y 3W
3W
S xy f f S ab g b b S 3W
abf d d
D D D
S ghm S ef S cde S gh
h f
1600

1600
1600

1600
m
a e f h g h g
S abc S def h h
E E E
c
l l

9280

9280
a a
5500
5500

5500

5500
b b b
3 2 3 2 3 2
3 - WIRES SE CABLE,
230v, 60hz, AC SIDEWALK SIDEWALK SIDEWALK

POWER SERVICE ENTRANCE RAMP UP RAMP UP RAMP UP

2410 3470 520 3600 2000 2410 2050 2430 3120 2000 2410 2050 2430 3120 2000

12000 12000 12000

GROUND FLOOR SECOND FLOOR THIRD FLOOR

A LIGHTING LAYOUT B LIGHTING LAYOUT C LIGHTING LAYOUT


E-3 SCALE: 1:100 m E-3 SCALE: 1:100 m E-3 SCALE: 1:100 m

DESIGNED BY:
PROFESSIONAL ELECTRICAL ENGINEER: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


H.M. AQUINO E-3
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 3 4
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 1' 2 3 4 1 1' 2 3 4 1 1' 2 3 4

12010 12010 12010

2000 2880 600 4120 2420 2000 2270 850 670 680 840 2270 2420 2000 2270 850 670 680 840 2270 2420

4 5 1 4 5 1 4 5 1
7090

7090

9490

9490

9490

9490
9
WCO
A A A
1250

15
REF

2750
1500

CO 14
17 18 12
RANGE CO CO
B WH
B B
22 CO ACU ACU

2280

2300

2280

2300
2380

2380
CO CO
CO CO
CO
24
24980

24990

24990
24990

24990

24990
1620

1620
1620

1620
WH CO
CO CO 23 CO WH
16 11

CO
3500

3500 CO CO
CO 21
C C ACU 19 C

2320

2300

2320

2300
ACU ACU
CO CO CO
CO CO CO CO CO CO CO
TV

20
T-P 10 ACU

2180
2170

2180

2180
CO

8 CO 25 CO 13
D D D
CO
1600

1600
1600

1600
WCO CO
WH CO WCO

E E E

9280

9280
WCO
5500
5500

5500

5500
3 2 3 2 3 2
3 - WIRES SE CABLE,
230v, 60hz, AC SIDEWALK SIDEWALK SIDEWALK

POWER SERVICE ENTRANCE RAMP UP RAMP UP RAMP UP

2410 3470 520 3600 2000 2410 2050 2430 3120 2000 2410 2050 2430 3120 2000

12000 12000 12000

GROUND FLOOR SECOND FLOOR THIRD FLOOR

A POWER LAYOUT B POWER LAYOUT C POWER LAYOUT


E-4 SCALE: 1:100 m E-4 SCALE: 1:100 m E-4 SCALE: 1:100 m

DESIGNED BY:
PROFESSIONAL ELECTRICAL ENGINEER: CIVIL ENGINEER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


H.M. AQUINO E-4
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 4 4
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
PLUMBING NOTE : SPECIFICATION : PLUMBING FIXTURE CONNECTION SIZE SCHEDULE LEGEND:
MIN. PIPE CONNECTION SIZE MM DIAMETER F FAUCET
1. ALL PLUMBING SPECIFICATIONS HEREIN SHALL BE MADE IN ACCORDANCE WITH THE HOT & COLD WATER LINES SHALL BE POLYPROPYLENE (PPR) PIPE, PN20 "POLYMUTAN"BRAND BRAND OR SYMBOL FIXTURES
WASTE/ VENT STORM COLD HOT
REMARKS GV GATE VALVE
RULES AND REGULATIONS OF THE LATEST EDITION OF THE PHIL. NATIONAL PLUMBING BRAND OR APPROVED EQUAL. SOIL WATER WATER
CV CHECK VALVE
CODE, ALL NATIONAL AND MUNICIPAL LAWS, LOCAL ORDINANCES,REGULATIONS OF THE SHALL BE POLYVINYL CHLORIDE (PVC) PIPE, SERIES 1000 "NELTEX - SANIGUARD" WC
WATER
100 50
_
15
_ TANK TYPE
DEPARTMENT OF HEALTH AND REQUIREMENTS OF UTILITY COMPANY CONCERNED. SEWER/WASTE PIPE CLOSET WM WATER METER
BRAND. _
LAV LAVATORY 50 50 15 15 WITH P - TRAP HB HOSE BIDD
2. THE LOCATION OF PIPES MAYBE TRANSFERED WHENEVER REQUIRED FOR THE PROPER SHALL BE POLYVINYL CHLORIDE (PVC) PIPE, SERIES 600 "NELTEX - SANIGUARD"
EXECUTION OF OTHER TRADES PROVIDED, THAT SUCH CHANGES CONFORMS WITH VENT PIPE KS
KITCHEN
SINK 50 50
_
15 15
WITH WATER
FILTER
FD FLOOR DRAIN
BRAND.
THE RULES AND REQUIREMENTS OF THE ARCHITECT. WATER _ _ _ INSTANTANEOUS
CB CATCH BASIN
SHALL BE POLYVINYL CHLORIDE (PVC) PIPE, SERIES 600 "NELTEX - SANIGUARD" WH HEATER 15 15
DOWNSPOUTS & DRAINAGE LINES DC DIGESTIVE CHAMBER
3. ALL PIPE JOINTS SHALL BE MADE WATER TIGHT AND PROPERLY SEALED USING THE BRAND. LAUNDRY _ _ _ WITH P - TRAP
LS SINK 75 15 LW LEACHING WELL
FOLLOWING: PVC PIPES SOLVENT CEMENT - FOR PVC PIPES & FITTINGS SHALL BE POLYVINYL CHLORIDE (PVC) PIPE, CLASS 125 "NELTEX BLUE" BRAND. SHOWER
TEFLON TAPE - FOR GALVANIZED IRON PIPES & FITTINGS FCU DRAIN PIPE SH
_
50
_
15
_ KS KITCHEN SINK
PROVIDE RUBBERIZED INSULATION "ARMAFLEX" BRAND FOR EXPOSED PIPE.
CEMENT MORTAR - FOR CONCRETE PIPES (CULVERT) WASHING _ SV SHOWER VALVE
GASKET CEMENT - FOR GALVANIZED IRON PIPES & FITTINGS GATE VALVE SHALL BE RISING STEM RATED 125 PSIG. "KITZ OR TOZEN" BRAND.
WM MACHINE 75 50 75 20
RTA RUN THRU ABOVE
OAKUM & PEG LEAD - FOR CAST IRON PIPES & FITTINGS. HB
HOSE
BIBB
_ _ _
15
_
RTB RUN THRU BELOW
CHECK VALVE _ _ _ _ WITH P - TRAP
4. MATERIALS TO BE USED FOR THE PIPING SYSTEM SHALL BE AS FOLLOWS: SHALL BE RISING STEM RATED 125 PSIG. "KITZ OR TOZEN" BRAND. UR URINAL 15 SHO SHOWER HEAD
G.I. PIPES & FITTINGS FOR MAIN WATER SUPPLY LINE. FLOOR _ _ _ WITH P - TRAP WC WATER CLOSET
PVC PIPES & FITTINGS FOR IN HOUSE WATER SUPPLY RISER & BRANCHES. PVC PIPES & FD DRAIN 50 50
WATER HEATER MULTI-POINT INSTANTANEOUS (6.0 KW.)"NATIONAL, STORAGE TYPE CAP=10 GALS. VSTR VENT STACK THRU ROOF
FITTINGS - FOR SOIL WASTE VENT & STORM WATER LINES (DOWNSPOUT).CONCRETE PIPE (3.0 KW.) "NORTHERN HILL" BRAND. FLOOR _ _
FD 2 DRAIN 2 75 50 75 TFD TERRACE FLOOR DRAIN
(CULVERT) - THE STORM DRAINAGE LINES BELOW THE GROUND VENT PIPES SHALL DECK _ _ _ _
WATER METER "ARAD" BRAND OR MWSS APPOVED EQUAL. DD DRAIN 75 SFD SHOWER FLOOR DRAIN
EXTEND FROM THE TOP OF THE ROOF AT LEAST 200MM FOR FLAT ROOFS AND 300MM FOR
LAUNDRY _ _ _ _ CWL COLD WATER LINE
SLOPING ROOFS, ALL VSTR OPENING MUST BE COVERED BY USING A WIRE SCREEN. LD DRAIN 75 WITHOUT P - TRAP
BOOSTER PUMP "GOULDS" BRAND.
ACU _ _ _ _ LAV LAVATORY
ACUD DRAIN 25
5. ALL HORIZONTAL PIPES SHALL MAINTAIN A MINIMUM SLOPE OF PVC POLYVINYL CHLORIDE
1/4 PER FOOT (12%). SUMP PUMP "GOULDS" BRAND.
ACU _ _ _ _ PROVIDE TO ALL ACU PVCSP PVC SOIL PIPE
FCUD 50 (SEE MECHANICAL DRAWINGS)

6. NO ARTESIAN WELL SHALL BE DONE WITHIN A RADIUS OF DRAIN TAP TO NEAREST STORM DRAIN LINE
PVCWP PVC WASTE PIPE
TWENTY FIVE (25) METERS FROM THE PROPOSED SEPTIC VAULT. HOT WATER PRE MOLDED 25 MM THICK FIBERGLASS WITH ALUMINUM VAPOR BARRIER PVCDP PVC DRAINAGE PIPE
DRAIN PIPE INSULATION 48 KG/CM.
DOWN
_ _ _ _
PROVIDE TO ALL ACU

7. ALL PLUMBING WORKS HEREIN SHALL BE DONE BY COMPETENT DS


SPOUT
75
(SEE MECHANICAL DRAWINGS)
TAP TO NEAREST STORM DRAIN LINE
PVCDSP PVC DOWNSPOUT PIPE
PLUMBERS UNDER THE DIRECT SUPERVISION OF A DULY REGISTERED MASTER PLUMBER. DRAIN & CLEANOUTS ALL DRAINS & CLEANOUTS SHALL BE BRONZE / BRASS TOP, "UNILEX" PVCVSTR PVC VENT STACK THRU ROOF
BRAND OR EQUAL. GUTTER _ _ _ _
GD DRAIN 75 PROVIDE 2% SLOPE

100 300 100


TO STREET
DRAINAGE LINE
100 1000 100 1000 100 1400 100

THE SITE
LOT 17 BLOCK 02 PHASE 6
TAGAK ST. BANKER VILLAGE,
BRGY. STA. CRUZ, ANTIPOLO CITY

600 600 600


600X600MM
MANHOLE

100 300 100

PLAN OF SEPTIC TANK


SCALE
TRENCH DRAIN / AREA DR. DETAILS WATER CLOSET MOUNTING DETAIL NTS

C.O. MH C.O. MH C.O. MH C.O. SINK


NATURAL GROUND LINE 100 300 (CB / AD) 100
PIPE 500 (TRENCH) P-TRAP

WATER SEAL

TO STREET DRAINAGE PROPERTY LINE


LINE
CLEAN OUT PLUG
CRUSHED GRAVEL FILL FLOOR DRAIN
UP TO HIGHEST WATER LEVEL
LEACHING DIGESTION DIGESTION CLEAN OUT
CHAMBER CHAMBER-2 CHAMBER-1

SIDEWALK LEVEL
2% SLOPE STREET DRAIN

SECTION OF SEPTIC TANK


CATCH BASIN

SCALE SCALE SCALE SCALE


SEPTIC TANK DETAILS NTS CATCH BASIN DETAILS NTS LAVATORY MOUNTING DETAIL NTS AIR CHAMBER DETAIL NTS
DESIGNED BY:
ARCHITECT: MASTER PLUMBER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


M.ESPIRITU P-1
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 1 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 2 3 4 1 1' 2 2' 3 4 1 1' 2 2' 3 4

12010 12010 12010

2000 2880 600 4120 2420 2000 2270 850 670 680 840 2270 2420 1000 1000 7580 1010 1410

4 5 1 4 5 1 4 5 1

5280

5270
7090

7090

9500

9490

810

3210
SINK

2400
f
A
gv f
1250

KS

2750
gv f f f
SHO HB WC LAV
1500

2690
B B
f
SHO

2280

2300
2380

2380

5500
f
LAV

f WC gv f f
HB

24990

24990
24980

24990

24990

24990
gv LAV HB WC SHO

1620

1620

3010
HB
SHO
gv f WC LAV
f
3500

3500
RFB
RTA RFB

C C C gv

1000
2320

2300
f

800
SINK

3000

3000
2170

2180

2180

3780
D D f
D
gv f
HB WC LAV
1600

1600

1600

1500
SHO

2990
E E

1600
gv
f
HB
5500

5500

5500

5500

3010
2900
FROM STREET
SERVICE
WATER LINE

1000

1000
3 2 3 2 3 2

SIDEWALK SIDEWALK SIDEWALK

RAMP UP RAMP UP RAMP UP

2410 3470 520 3600 2000 2410 2050 2430 3120 2000 1410 1000 1350 3000 1840 1400 1000 1000

12000 12000 12000

A GROUND FLOOR WATER LINE LAYOUT B SECOND FLOOR WATER LINE LAYOUT C THIRD FLOOR WATER LINE LAYOUT
P-2 SCALE 1:100m P-2 SCALE 1:100m P-2 SCALE 1:100m

DESIGNED BY:
ARCHITECT: MASTER PLUMBER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


P-2
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 2 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 2 3 4 1 1' 2 2' 3 4 1 1' 2 2' 3 4

12010 12010 12010

2000 2880 600 4120 2420 2000 2270 850 670 680 840 2270 2420 1000 1000 7580 1010 1410

4 5 1 4 5 1 4 5 1

5280

5270
7090

7090

9500

9490

810
FD

3210
2400
A
1250

FD

2750
VSTR

CO
1500

CO

2690
B CO B

2280

2300
2380

2380

5500
FD
VSTR VSTR

24990

24990
24980

24990

24990

24990
1620

1620

3010
FD

RTA RTA VSTR


CO RFB
3500

3500
SS SS SS
C C C

1000
2320

2300

800
3000

3000
2170

2180
2180

3780
RFB
D RTA D VSTR
CO D
SS SS
1600

1600

1600

1500
FD

2990
E E

1600
5500

5500

5500

5500

3010
2900
TO STREET
DRAINAGE

1000

1000
3 2 3 2 3 2

SIDEWALK SIDEWALK SIDEWALK

RAMP UP RAMP UP RAMP UP

2410 3470 520 3600 2000 2410 2050 2430 3120 2000 1410 1000 1350 3000 1840 1400 1000 1000

12000 12000 12000

A GROUND FLOOR SEWER LINE LAYOUT B SECOND FLOOR SEWER LINE LAYOUT C THIRD FLOOR SEWER LINE LAYOUT
P-3 SCALE 1:100m P-3 SCALE 1:100m P-3 SCALE 1:100m

DESIGNED BY:
ARCHITECT: MASTER PLUMBER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


P-3
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 3 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
1 2 3 4 1 1' 2 2' 3 4 1 1' 2 2' 3 4 1 1' 2 2' 3 4

12010
12010 12010 2000 3800 3800 2410
1980 900 920 3800
2000 2880 600 4120 2420 2000 2270 850 670 680 840 2270 2420 1000 1000 7580 1010 1410

uPVC uPVC uPVC


DOWN DOWN DOWN
SPOUT DS SPOUT DS SPOUT DS
A
CB CB CB
A DS
DS DS

uPVC uPVC uPVC


DOWN DOWN DOWN
SPOUT DS SPOUT DS SPOUT DS

B B B

DS CB
CB DS
uPVC uPVC uPVC
DOWN DOWN DOWN
DS DS DS SPOUT DS SPOUT DS SPOUT DS

C C C C

DS CB

D D D D
FD

FD

E E FD E

SIDEWALK SIDEWALK SIDEWALK SIDEWALK

RAMP UP RAMP UP RAMP UP RAMP UP


2410 3470 520 3600 2000 2410 2050 2430 3120 2000 1410 1000 1350 3000 1840 1400 1000 1000
2400 1300
2410 3890 3700 2010
12000

A GROUND FLOOR STORM DRAIN LAYOUT B SECOND FLOOR STORM DRAIN LAYOUT C THIRD FLOOR STORM DRAIN LAYOUT D ROOF STORM DRAIN LAYOUT
P-4 SCALE 1:100m P-4 SCALE 1:100m P-4 SCALE 1:100m P-4 SCALE 1:100m

DESIGNED BY:
ARCHITECT: MASTER PLUMBER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


P-4
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 4 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING
A ISOMETRIC WATER LINE LAYOUT B ISOMETRIC SEWER LINE LAYOUT C ISOMETRIC STORM DRAIN LAYOUT
P-5 SCALE 1:120m P-5 SCALE 1:120m P-5 SCALE 1:150m

DESIGNED BY:
ARCHITECT: MASTER PLUMBER: PROJECT OWNER/S: PROJECT TITLE: SHEET CONTENTS: SHEET

NOVILLOS DESIGN & BUILD PROPOSED THREE-STOREY RESIDENCE DRAWN BY:


P-5
1F UNIT 18 CONGRESSIONAL TOWN CENTER, CONGRESSIONAL AVENUE, CHECKED BY:
BAHAY TORO, QUEZON CITY MR. JOSE ABENIR LOCATION: AS SHOWN 5 5
ncr@novconph.com | +639167994047 PTR NO: DATE ISSUED: ISSUED AT: PTR NO: DATE ISSUED: ISSUED AT:
LOT 17 BLOCK 02 PHASE 6 TAGAK ST. BANKER VILLAGE, DATE:
PRC NO: EXP. DATE: TIN NO.: PRC NO: EXP. DATE: TIN NO.: BRGY. STA. CRUZ, ANTIPOLO CITY DRAWING