Folding Grab Rail too Item- A

high, shall be 725-


750mmH

provide the image Item- C


and video for
demonstrating the air
intake in the room
change to visual
signal
Item- B
To provide the
access panel photo

Item- B

Accessible toilet:- Item- A


1. call bell installation outstanding
2. A notice “Emergency Call” in
both English, Chinese and Braille shall be fitted next to the emergency
push
button.
3. Wash basin too high, shall not be higher than 750mmH
4. Door handle too high (850mmH), shall be 800mmH.
5. Mirror outstanding
6. U-trap of wash basin outstanding, be aware the U-trap shall not be
within the 1500x1500 maneuvering space.

Item- A4 Item- A3 Item- A2 Item- A1

provide site photos


with glasses installed.

Item- A5

Item- A6
A notice “Emergency Call” in
both English, Chinese and Braille shall be
change VP to visual
fitted next to the emergency push
alarm system
door self closer
missing Item- C
Item- B
Item-A
Windows in shall
all wards
be openable,
shall be
rectificationrectification
openable, photos to bephotos
provided.
to be
Item- A
provided.

Accessible toilet:-
1. A notice “Emergency Call” in both English, Chinese and Braille shall
be fitted next to the emergency push button. Item- B
2. U-trap of wash basin clashed with the 1500x1500 maneuvering
space. The piping shall be revised.
3. grab bar