Download as pdf or txt
Download as pdf or txt
You are on page 1of 330

Nokia 

Networks

LTE Radio Access, Rel. FDD-
LTE 16, Operating
Documentation, Issue 02

Installing Flexi Multiradio
Base Station and Flexi
Multiradio 10 Base Station
Optional Items 
DN09142359
Issue 05
Approval Date 2016-02-17
 
 
 
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

The  information  in  this  document  applies  solely  to  the  hardware/software  product  (“Product”)  specified
herein, and only as specified herein.

This document is intended for use by Nokia Solutions and Networks' customers (“You”) only, and it may not
be used except for the purposes defined in the agreement between You and Nokia Solutions and Networks
(“Agreement”)  under  which  this  document  is  distributed.  No  part  of  this  document  may  be  used,  copied,
reproduced,  modified  or  transmitted  in  any  form  or  means  without  the  prior  written  permission  of  Nokia
Solutions  and  Networks.  If  you  have  not  entered  into  an  Agreement  applicable  to  the  Product,  or  if  that
Agreement has expired or has been terminated, You may not use this document in any manner and You
are obliged to return it to Nokia Solutions and Networks and destroy or delete any copies thereof.

The  document  has  been  prepared  to  be  used  by  professional  and  properly  trained  personnel,  and  You
assume full responsibility when using it. Nokia Solutions and Networks welcome Your comments as part of
the process of continuous development and improvement of the documentation.

This  document  and  its  contents  are  provided  as  a  convenience  to  You.  Any  information  or  statements
concerning the suitability, capacity, fitness for purpose or performance of the Product are given solely on
an “as is” and “as available” basis in this document, and Nokia Solutions and Networks reserves the right
to change any such information and statements without notice. Nokia Solutions and Networks has made all
reasonable efforts to ensure that the content of this document is adequate and free of material errors and
omissions,  and  Nokia  Solutions  and  Networks  will  correct  errors  that  You  identify  in  this  document.  But,
Nokia Solutions and Networks' total liability for any errors in the document is strictly limited to the correction
of such error(s). Nokia Solutions and Networks does not warrant that the use of the software in the Product
will be uninterrupted or error-free.

NO  WARRANTY  OF  ANY  KIND,  EITHER  EXPRESS  OR  IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO
ANY  WARRANTY  OF  AVAILABILITY,  ACCURACY,  RELIABILITY,  TITLE,  NON-INFRINGEMENT,
MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE,  IS  MADE  IN  RELATION  TO  THE
CONTENT  OF  THIS  DOCUMENT.  IN  NO  EVENT  WILL  NOKIA  SOLUTIONS  AND  NETWORKS  BE
LIABLE  FOR  ANY  DAMAGES,  INCLUDING  BUT  NOT  LIMITED  TO  SPECIAL,  DIRECT,  INDIRECT,
INCIDENTAL  OR  CONSEQUENTIAL  OR  ANY  LOSSES,  SUCH  AS  BUT  NOT  LIMITED  TO  LOSS  OF
PROFIT,  REVENUE,  BUSINESS  INTERRUPTION,  BUSINESS  OPPORTUNITY  OR  DATA  THAT  MAY
ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT, EVEN IN THE CASE OF
ERRORS IN OR OMISSIONS FROM THIS DOCUMENT OR ITS CONTENT.

This document is Nokia Solutions and Networks’ proprietary and confidential information, which may not be
distributed  or  disclosed  to  any  third  parties  without  the  prior  written  consent  of  Nokia  Solutions  and
Networks.

Nokia  is  a  registered  trademark  of  Nokia  Corporation.  Other  product  names  mentioned  in  this  document
may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © 2016 Nokia Solutions and Networks. All rights reserved.

f Important Notice on Product Safety
  This product may present safety risks due to laser, electricity, heat, and other sources of danger.

Only  trained  and  qualified  personnel  may  install,  operate,  maintain  or  otherwise  handle  this
product and only after having carefully read the safety information applicable to this product.

The  safety  information  is  provided  in  the  Safety  Information  section  in  the  “Legal,  Safety  and
Environmental Information” part of this document or documentation set.

Nokia  Solutions  and  Networks  is  continually  striving  to  reduce  the  adverse  environmental  effects  of  its
products and services. We would like to encourage you as our customers and users to join us in working
towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations
for power use and proper disposal of our products and their components.

If you should have questions regarding our Environmental Policy or any of the environmental services we
offer, please contact us at Nokia Solutions and Networks for any additional information.

2 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Table of Contents
This document has 330 pages
   
Summary of changes................................................................... 19
   
1 Installing System Extension Module............................................ 21
   
2 Installing Flexi Pole Installation Kit (FPIA)................................... 23
   
3 Installing Flexi Mounting Auxiliary Brackets (FMAA)....................26
   
4 Installing Flexi Mounting Covers (FMCA/FMCH/FMCB) back..... 29
   
5 Installing Flexi Mounting Covers (FMCA/FMCH/FMCB) front...... 32
   
6 Installing Flexi Side Covers (FMHA/FMTA)..................................34
   
7 Installing Flexi Power Module (FPMA)......................................... 37
7.1 Installing Flexi Power Module (FPMA)......................................... 37
7.2 Powering an RF Module with a single FPMA equipped with one
rectifier......................................................................................... 55
7.3 Powering an RF Module with a single FPMA equipped with 4
rectifiers/batteries.........................................................................56
7.4 Powering two System Modules with a single FPMA.................... 64
   
8 Installing Flexi Power DC/DC Module 24V (FPDA)......................68
   
9 Principles for installing Flexi Power Rectifier (FPRx) in Flexi
Multiradio BTS configurations...................................................... 77
   
10 Installing Flexi Power AC/DC sub-module 230V (FPAD/FPAE)... 79
10.1 Installing Flexi Power AC/DC sub-module (FPAD) on a wall....... 79
10.2 Installing Flexi Power AC/DC sub-module (FPAD) to a pole-
mounted RRH.............................................................................. 84
10.3 Installing Flexi Power AC/DC sub-module (FPAE) on a wall........92
10.4 Installing Flexi Power AC/DC sub-module (FPAE) to a pole-
mounted RRH.............................................................................. 97
10.5 Installing Flexi Power AC/DC sub-module (FPAD/FPAE) on a pole
................................................................................................... 103
   
11 Installing Flexi Power Distribution and Fuses Outdoor (FPFC)
(Efore)........................................................................................ 109
11.1 Installing Flexi Power Distribution and Fuses Outdoor (FPFC)
(Efore) inside a casing................................................................110
11.2 Installing Flexi Power Distribution and Fuses Outdoor (FPFC)
(Efore) in a chained configuration.............................................. 123
   
12 Installing Flexi Power Distribution and Fuses Outdoor (FPFC)
(AcBel)....................................................................................... 126
12.1 Installing Flexi Power Distribution and Fuses Outdoor (FPFC)
(AcBel) inside a casing...............................................................127

Issue: 05 DN09142359 3
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

12.2 Installing Flexi Power Distribution and Fuses Outdoor (FPFC)
(AcBel) in a chained configuration............................................. 142
   
13 Installing Flexi System External OVP (FSES)............................144
13.1 Installing Flexi System External OVP (FSES) onto a 3U casing......
144
13.2 Installing Flexi System External OVP (FSES) on a Flexi cabinet
rooftop........................................................................................ 158
13.3 Installing Flexi System External OVP (FSES) onto Flexi Pole
Installation Kit (FPIA)................................................................. 160
   
14 Installing Flexi System External OVP (FSEP)............................164
14.1 Installing Flexi System External OVP (FSEP) onto a 3U casing......
164
14.2 Installing Flexi System External OVP (FSEP) on a Flexi cabinet
rooftop........................................................................................ 177
14.3 Installing Flexi System External OVP (FSEP) onto Flexi Pole
Installation Kit (FPIA)................................................................. 179
   
15 Installing Flexi Fiber Optical Distribution unit (FODA)................183
15.1 Installing Flexi Fiber Optical Distribution unit (FODA) in a stack......
183
15.2 Installing Flexi Fiber Optical Distribution unit (FODA) on a wall.191
15.3 Installing Flexi Fiber Optical Distribution unit (FODA) on a pole......
196
   
16 Installing Flexi System External Alarm (FSEB).......................... 203
16.1 Installing Flexi System External Alarm (FSEB).......................... 203
16.2 FSEB interface signals and connector pin assignments............ 216
16.3 EAC cable (FTSI 472578A) wiring............................................. 221
   
17 Installing GPS GLONASS Receiver Antenna (FYGB)............... 223
   
18 Installing Flexi GPS Surge Protection Kit (FYEA) v. 103............228
   
19 Installing Flexi GPS Surge Protection Kit (FYEA) v. 104............235
   
20 Installing Flexi GPS Box (FYGD)............................................... 243
   
21 Installing Flexi Enhanced External GNSS Box (FYGE)............. 247
21.1 Installing Flexi Enhanced External GNSS Box (FYGE) inside Flexi
System Module (FSMF)............................................................. 247
21.2 Installing FYGE inside of FCOB.................................................250
21.3 Installing FYGG inside of FCOB................................................ 255
21.4 Installing Flexi Enhanced External GNSS Box (FYGE) on a 19-
inch rack.....................................................................................261
21.5 Installing Flexi Enhanced External GNSS Box (FYGE) on top of
Flexi System Module (FSIH)...................................................... 264
21.6 Installing Flexi Enhanced External GNSS Box (FYGE) below Flexi
System Module (FSIH)...............................................................268
21.7 Installing Flexi Enhanced External GNSS Box (FYGE) on the wall.
272

4 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

   
22 Installing OD External GNSS Enhanced Holdover (FYGG)....... 274
22.1 Installing OD External GNSS Enhanced Holdover (FYGG) inside
Flexi System Module (FSMF).....................................................274
22.2 Installing OD External GNSS Enhanced Holdover (FYGG) on a
19-inch rack................................................................................277
22.3 Installing OD External GNSS Enhanced Holdover (FYGG) on top
of Flexi System Module (FSIH).................................................. 280
22.4 Installing OD External GNSS Enhanced Holdover (FYGG) below
Flexi System Module (FSIH)...................................................... 284
22.5 Installing OD External GNSS Enhanced Holdover (FYGG) on the
wall............................................................................................. 288
22.6 Installing OD External GNSS Enhanced Holdover (FYGG) on the
pole............................................................................................ 289
   
23 Installing Flexi Filters (FFNT/FFNU).......................................... 292
23.1 Installing Flexi Filters (FFNT/FFNU) on the pole........................292
23.2 Installing Flexi Filters (FFNT/FFNU) on the wall........................ 295
   
24 Installing Cable Holder for Flexi System Module 10 indoor
FSIH/FBIH (FCHB).....................................................................296
   
25 Appendix Contents of deliveries.................................................298
25.1 Contents of the System Extension Kit (FSKA) delivery..............298
25.2 Contents of the Flexi Pole Installation Kit (FPIA) delivery..........298
25.3 Contents of the Flexi Mounting Auxiliary Bracket (FMAA)......... 299
25.4 Contents of the 3U mounting covers (FMCA) delivery...............300
25.5 Contents of the Flexi 3U High Covers Mounting Covers Front/back
(FMCH) delivery......................................................................... 301
25.6 Contents of the Flexi Mounting Covers Front and Back, 2U
(FMCB) delivery......................................................................... 303
25.7 Contents of the 3U Module Casings (EMHA) delivery............... 304
25.8 Contents of the Flexi 3U Casing and High Covers F&B (EMHH)
delivery.......................................................................................305
25.9 Contents of the 2U Module Casings (EMTA) delivery................ 306
25.10 Contents of the Flexi Side Covers (FMHA) delivery...................308
25.11 Contents of the Flexi Side Covers (FMTA) delivery................... 309
25.12 Contents of the Flexi Power Module (FPMA) delivery............... 310
25.12.1 Contents of the power AC/DC sub-module (FPAA) delivery...... 311
25.12.2 Contents of the power battery sub-module (FPBB) delivery...... 312
25.13 Contents of the 24V Power Module (FPDA) delivery................. 313
25.14 Contents of the Flexi Power AC/DC sub-module (FPAD) delivery...
314
25.15 Contents of the Flexi Power AC/DC sub-module (FPAE) delivery...
315
25.16 Contents of the Flexi Power Distribution and Fuses Outdoor
(FPFC) (Efore) delivery.............................................................. 315
25.17 Contents of the Flexi Power Distribution and Fuses Outdoor
(FPFC) (AcBel) delivery............................................................. 317
25.18 Contents of the Flexi System External OVP (FSES) delivery.... 318

Issue: 05 DN09142359 5
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

25.19 Contents of the Flexi System External OVP (FSEP) delivery.... 319


25.20 Contents of the Flexi Fiber Optical Distribution unit (FODA)
delivery.......................................................................................320
25.21 Contents of the Flexi System External Alarm Module (FSEB)... 321
25.22 Contents of the GPS hardware deliveries.................................. 322
25.23 Contents of the Flexi GPS Surge Protection Kit (FYEA) delivery....
324
25.24 Contents of the GPS Box (FYGD) delivery................................ 325
25.25 Contents of the Flexi Enhanced External GPS Box (FYGE)
delivery.......................................................................................326
25.26 Contents of the OD External GNSS Enhanced Holdover (FYGG)
delivery.......................................................................................327
25.27 Contents of the Flexi Filter (FFNT/FFNU) deliveries..................327
   
26 Appendix Installation tools and torque values............................328
26.1 BTS installation tools and equipment.........................................328
26.2 Torque values.............................................................................329

6 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

List of Figures
Figure 1 Example: installing FYEA on the installation plate............................. 23
Figure 2 Threading the straining strap..............................................................24
Figure 3 Installing the FPIA to the pole.............................................................25
Figure 4 Flexi Mounting Auxiliary Brackets (FMAA)......................................... 26
Figure 5 Installing FMAA with FSEB.................................................................27
Figure 6 Fixing maintenance strap to back cover............................................. 30
Figure 7 Snap hook fixing point........................................................................ 30
Figure 8 Maintanance strap.............................................................................. 31
Figure 9 Fixing maintenance strap to front cover............................................. 32
Figure 10 Hook fixing point................................................................................. 33
Figure 11 Flexi Side Covers 3U (FMHA)............................................................ 34
Figure 12 Stack installation with cable tunnels................................................... 36
Figure 13 Two FPMAs stacked...........................................................................38
Figure 14 Positive grounding.............................................................................. 39
Figure 15 FPMA provisioning for configurations with one FPMA....................... 40
Figure 16 FPMA provisioning for configurations with two FPMAs...................... 40
Figure 17 FPMA provisioning for configurations with new and old version FPMA.
40
Figure 18 FPMA provisioning for configurations with two FPMAs...................... 41
Figure 19 FPMA cable harness nuts.................................................................. 41
Figure 20 Connecting grounding cable and installing DC cable harness........... 42
Figure 21 Installing FPMA DC cable harness.....................................................42
Figure 22 Removing the ingress protection plate............................................... 43
Figure 23 Removing the AC terminal enclosure................................................. 43
Figure 24 Detaching the AC terminal..................................................................44
Figure 25 Routing the AC cable through the ingress protection plate................ 44
Figure 26 Single phase connection 230 V AC.................................................... 45
Figure 27 3-phase star connection 230 V AC.....................................................45
Figure 28 3-phase delta connection, base voltage 100-120 V AC (200-240 V AC
potential difference)............................................................................ 46
Figure 29 3-phase delta connection 110 V AC................................................... 46
Figure 30 Installing sub-modules........................................................................47
Figure 31 Changing the FPAA fan airflow direction (AcBel)............................... 48
Figure 32 Changing the FPAA fan airflow direction (Efore)................................ 48
Figure 33 Connecting the AC cable....................................................................49
Figure 34 Connecting the alarm cables.............................................................. 49
Figure 35 Connecting the DC cables..................................................................50
Figure 36 Replacing the ingress protection plate............................................... 51
Figure 37 Installing cable entries........................................................................ 51

Issue: 05 DN09142359 7
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 38 Installing second FPMA......................................................................52
Figure 39 Installing second FPMA......................................................................53
Figure 40 Connecting the DC power feed cable (FSMF)....................................54
Figure 41 Example configuration........................................................................ 56
Figure 42 Connector removed from cable 994808............................................. 57
Figure 43 Stripped power cable..........................................................................57
Figure 44 Detached DC cable harness...............................................................58
Figure 45 Removed IP boots.............................................................................. 58
Figure 46 Removed cable terminals, washers and nuts.....................................59
Figure 47 IP boot heads..................................................................................... 59
Figure 48 Cutting the IP boots............................................................................ 60
Figure 49 Routing the power cables through the IP boots..................................60
Figure 50 Stripping the - cable............................................................................61
Figure 51 Attaching the protection tubes............................................................ 61
Figure 52 Cable terminals attached....................................................................62
Figure 53 Using plastic insulation bands............................................................ 62
Figure 54 Fixing the power cables to DC connectors......................................... 63
Figure 55 Attaching the IP boots........................................................................ 63
Figure 56 DC cable harness power cables.........................................................64
Figure 57 Removing the IP boots....................................................................... 65
Figure 58 Connecting power cables................................................................... 66
Figure 59 Powering two System Modules with one FPMA................................. 67
Figure 60 Flexi Power DC/DC Module 24V (FPDA) front panel......................... 68
Figure 61 FPDA provisioning for configurations with one FPDA........................ 68
Figure 62 FPDA provisioning for configurations with two FPDAs.......................69
Figure 63 FPDA provisioning for configurations with three FPDAs and two
System Modules (sample 1)............................................................... 69
Figure 64 FPDA provisioning for configurations with three FPDAs and two
System Modules (sample 2)............................................................... 70
Figure 65 FPDA provisioning for configurations with three FPDAs and one
System Module (sample 3).................................................................70
Figure 66 FPDA provisioning for configurations with four FPDAs and two System
Modules.............................................................................................. 71
Figure 67 Parallel FPDAs with paired (chained) DC cables and boots.............. 72
Figure 68 Fixing cable entries.............................................................................73
Figure 69 Connecting grounding cable to plinth................................................. 73
Figure 70 Connecting DC output cables to FPDA.............................................. 74
Figure 71 Connecting alarm cable......................................................................75
Figure 72 AC interface support...........................................................................77
Figure 73 Opening the AC connector cover....................................................... 80
Figure 74 Loosening the AC cable clamp screws...............................................81

8 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 75 AC cable routing................................................................................. 81
Figure 76 Wires connected.................................................................................82
Figure 77 Closing the AC connector cover......................................................... 83
Figure 78 AC cable clamp screws fixed..............................................................83
Figure 79 Marking the fixing points.....................................................................84
Figure 80 Opening the AC connector cover....................................................... 86
Figure 81 Loosening the AC cable clamp screws...............................................87
Figure 82 AC cable routing................................................................................. 87
Figure 83 Wires connected.................................................................................88
Figure 84 Closing the AC connector cover......................................................... 89
Figure 85 AC cable clamp screws fixed..............................................................89
Figure 86 Fixing points....................................................................................... 90
Figure 87 FPAD installed using the right-hand side fixing points........................91
Figure 88 Opening the AC connector cover....................................................... 93
Figure 89 Loosening the AC cable clamp screws...............................................93
Figure 90 AC cable routing................................................................................. 94
Figure 91 Wires connected.................................................................................95
Figure 92 Closing the AC connector cover......................................................... 95
Figure 93 AC cable clamp screws fixed..............................................................96
Figure 94 Marking the fixing points.....................................................................96
Figure 95 FPAE offset mounting......................................................................... 98
Figure 96 Opening the AC connector cover....................................................... 99
Figure 97 Loosening the AC cable clamp screws...............................................99
Figure 98 AC cable routing............................................................................... 100
Figure 99 Wires connected...............................................................................101
Figure 100 Closing the AC connector cover....................................................... 101
Figure 101 AC cable clamp screws fixed............................................................102
Figure 102 Fixing points..................................................................................... 102
Figure 103 Opening the AC connector cover..................................................... 104
Figure 104 Loosening the AC cable clamp screws.............................................105
Figure 105 AC cable routing............................................................................... 105
Figure 106 Wires connected...............................................................................106
Figure 107 Closing the AC connector cover....................................................... 107
Figure 108 AC cable clamp screws fixed............................................................107
Figure 109 Fixing brackets................................................................................. 108
Figure 110 Flexi Power Distribution and Fuses Outdoor (FPFC)....................... 109
Figure 111 FPFC installation example................................................................ 110
Figure 112 FPFC (Efore) grounding points......................................................... 111
Figure 113 EAC cable routing............................................................................. 112
Figure 114 Cable outer jacket stripping (input from right-hand side).................. 112

Issue: 05 DN09142359 9
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 115 Cable outer jacket stripping (input from left-hand side).................... 113


Figure 116 Three-fingered cold shrink tube installed.......................................... 113
Figure 117 Cable diameters for input IP boot..................................................... 114
Figure 118 Cable diameter >20 mm (0.79 in.) (input from right-hand side)........ 114
Figure 119 Cable diameter >20 mm (0.79 in.) (input from left-hand side).......... 115
Figure 120 Cable diameter <20 mm (0.79 in.).................................................... 115
Figure 121 Input cable connectors......................................................................116
Figure 122 Fixing the input cable connection..................................................... 116
Figure 123 Typical input cabling from right-hand side for single FPFC.............. 117
Figure 124 FPFC input cabling from both sides..................................................117
Figure 125 Cable outer jacket stripping (output from right-hand side)................ 118
Figure 126 Cable outer jacket stripping (output from left-hand side).................. 118
Figure 127 Three-fingered cold shrink tube installed.......................................... 118
Figure 128 IP boot cutting................................................................................... 119
Figure 129 Cable diameter >20 mm (0.79 in.)(output from right-hand side)...... 120
Figure 130 Cable diameter >20 mm (0.79 in.) (output from left-hand side)........120
Figure 131 Cable diameter <20 mm (0.79 in.).................................................... 120
Figure 132 Output cable connectors and GND, max values.............................. 121
Figure 133 Fixing the output cable connection................................................... 121
Figure 134 Cable routing in 2U casing with left-hand side input cabling............ 122
Figure 135 On/Off bar ‘On’ position.................................................................... 122
Figure 136 Adjusting the output current knob.....................................................123
Figure 137 Two FPFCs chained......................................................................... 124
Figure 138 Flexi Power Distribution and Fuses Outdoor (FPFC)....................... 126
Figure 139 FPFC installation example................................................................127
Figure 140 FPFC AcBel grounding points.......................................................... 128
Figure 141 EAC cable routing.............................................................................129
Figure 142 Cable outer jacket stripping (input from right-hand side)..................129
Figure 143 Cable outer jacket stripping (input from left-hand side).................... 130
Figure 144 Three-fingered cold shrink tube installed..........................................130
Figure 145 Cable diameters for input IP boot..................................................... 131
Figure 146 Cable diameter >20 mm (0.79 in.) (input from right-hand side)........131
Figure 147 Cable diameter >20 mm (0.79 in.) (input from left-hand side).......... 132
Figure 148 Cable diameter <20 mm (0.79 in.).................................................... 132
Figure 149 Input cable connectors..................................................................... 133
Figure 150 Fixing the input cable connection..................................................... 133
Figure 151 Typical input cabling from right-hand side for single FPFC.............. 134
Figure 152 FPFC input cabling from both sides................................................. 134
Figure 153 Cable outer jacket stripping (output from right-hand side)................135
Figure 154 Cable outer jacket stripping (output from left-hand side)..................135

10 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 155 Three-fingered cold shrink tube installed..........................................135
Figure 156 IP boot cutting...................................................................................136
Figure 157 Cable diameter >20 mm (0.79 in.)(output from right-hand side)...... 136
Figure 158 Cable diameter >20 mm (0.79 in.) (output from left-hand side)........137
Figure 159 Cable diameter <20 mm (0.79 in.).................................................... 137
Figure 160 Output cable connectors and GND, max values.............................. 138
Figure 161 Fixing the output cable connection................................................... 139
Figure 162 Cable routing in 2U casing with left-hand side input cabling............ 140
Figure 163 On/Off bar ‘On’ position.................................................................... 140
Figure 164 Adjusting the output current knob.....................................................141
Figure 165 Two FPFCs chained......................................................................... 143
Figure 166 FSES interfaces................................................................................144
Figure 167 Installing FSES on casing.................................................................145
Figure 168 Connecting FSES grounding cable to plinth.....................................146
Figure 169 Removing FSES IP boot...................................................................147
Figure 170 Wrapping tape around shielded DC cable........................................ 147
Figure 171 Wrapping an extra tape around DC cable........................................ 148
Figure 172 Inserting DC power cable to IP boot.................................................148
Figure 173 Removing narrow end of IP boot...................................................... 149
Figure 174 Properly secured shielded DC cable (left) and non-shielded DC cable
(right)................................................................................................ 150
Figure 175 Connecting DC feeder cable wires................................................... 150
Figure 176 Fixing IP boot screw......................................................................... 151
Figure 177 Example of conduit usage................................................................ 152
Figure 178 Fixing DC feeder cable to cable entry.............................................. 153
Figure 179 Fixing DC power cable with cable tie................................................153
Figure 180 Removing alarm port IP boot............................................................154
Figure 181 Removing IP plug............................................................................. 154
Figure 182 Inserting alarm cable to IP boot........................................................155
Figure 183 Connecting alarm cable wires.......................................................... 155
Figure 184 Fixing alarm cable IP boot................................................................ 156
Figure 185 Example of conduit usage................................................................ 157
Figure 186 Two FSES’s stacked.........................................................................158
Figure 187 Example of FCIA rooftop installation................................................ 159
Figure 188 Example of FCOA rooftop installation (with FSEB).......................... 159
Figure 189 FSES installed on FPIA.................................................................... 161
Figure 190 Two FSES’s on FPIA........................................................................ 162
Figure 191 Four FSES’s on FPIA....................................................................... 163
Figure 192 FSEP interfaces................................................................................164
Figure 193 Installing FSEP on casing.................................................................165

Issue: 05 DN09142359 11
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 194 Connecting FSEP grounding cable to plinth.....................................166
Figure 195 Removing 3-pole DC output IP boot.................................................167
Figure 196 Wrapping tape around shielded DC cable........................................ 167
Figure 197 Wrapping extra tape around DC cable............................................. 168
Figure 198 Inserting DC power cable to IP boot.................................................168
Figure 199 Removing narrow end of IP boot...................................................... 169
Figure 200 Properly secured shielded DC cable (left) and non-shielded DC cable
(right)................................................................................................ 170
Figure 201 Connecting DC feeder cable wires................................................... 170
Figure 202 Fixing IP boot screw......................................................................... 171
Figure 203 Example of conduit usage................................................................ 172
Figure 204 Fixing DC feeder cable to cable entry.............................................. 173
Figure 205 Connecting 2-pole DC input interface...............................................174
Figure 206 Connecting FSEP alarm cable......................................................... 175
Figure 207 Two FSEP’s stacked.........................................................................177
Figure 208 Example of FCIA rooftop installation................................................ 178
Figure 209 Example of FCOA rooftop installation (with FSEB).......................... 178
Figure 210 FSEP installed on FPIA.................................................................... 180
Figure 211 Two FSEP’s on FPIA........................................................................ 181
Figure 212 Four FSEP’s on FPIA....................................................................... 182
Figure 213 Flexi Fiber Optical Distribution unit (FODA)..................................... 183
Figure 214 Outdoor installation example............................................................ 184
Figure 215 Installation example with FODA....................................................... 185
Figure 216 Opening the lid of FODA.................................................................. 186
Figure 217 Routing cables through the cable gland........................................... 187
Figure 218 Routing fibers inside FODA.............................................................. 187
Figure 219 Tightening the cable gland................................................................188
Figure 220 Fixing the mounting brackets............................................................189
Figure 221 Installing FODA in a 3U casing together with FPFC.........................190
Figure 222 Installing FODA on top of a casing................................................... 190
Figure 223 Opening the lid of FODA.................................................................. 191
Figure 224 Routing cables through the cable gland........................................... 192
Figure 225 Tightening the cable gland................................................................193
Figure 226 Fixing the mounting bracket and the cable tie bracket..................... 194
Figure 227 Installing FODA on wall.................................................................... 195
Figure 228 Installing the front cover................................................................... 196
Figure 229 Opening the lid of FODA.................................................................. 197
Figure 230 Routing cables through the cable gland........................................... 198
Figure 231 Tightening the cable gland................................................................199
Figure 232 Fixing the mounting bracket and the cable tie bracket..................... 200

12 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 233 Installing FODA on a pole.................................................................201
Figure 234 Installing the front cover................................................................... 202
Figure 235 FSEB installed horizontally...............................................................203
Figure 236 FSEB installed vertically................................................................... 204
Figure 237 FSEB connectors..............................................................................204
Figure 238 Fixing FSEB cables.......................................................................... 205
Figure 239 FMAA with FSEB..............................................................................206
Figure 240 FSEB fixing points on the FCIA roof.................................................206
Figure 241 FSEB fixing points on the FCOA roof............................................... 207
Figure 242 Install FSEB with four M5 screws..................................................... 208
Figure 243 Connect the grounding cable............................................................209
Figure 244 Jumper X1103 in 12 Alarms mode................................................... 209
Figure 245 Connect the external alarms cable................................................... 211
Figure 246 Control outputs................................................................................. 214
Figure 247 Install the cover................................................................................ 215
Figure 248 FSEB printed wiring board................................................................216
Figure 249 GPS hardware.................................................................................. 224
Figure 250 GPS view..........................................................................................225
Figure 251 Installing the GPS/GNSS system on the wall................................... 225
Figure 252 Installing the GPS/GNSS system on the pole.................................. 226
Figure 253 Pole mounting band..........................................................................227
Figure 254 Pole mounting...................................................................................227
Figure 255 FYEA fixing points on the FCOA roof............................................... 228
Figure 256 Installing FPIA.................................................................................. 229
Figure 257 Opening the FYEA v. 103 lid............................................................ 230
Figure 258 Connecting the grounding cable (FYEA v. 103)............................... 230
Figure 259 Exposing the wires........................................................................... 232
Figure 260 Connecting cables (FYEA v. 103).....................................................233
Figure 261 Closing the FYEA v. 103 lid.............................................................. 234
Figure 262 FYEA fixing points on the FCOA roof............................................... 235
Figure 263 Installing FPIA.................................................................................. 236
Figure 264 Opening the FYEA v. 104 lid............................................................ 237
Figure 265 Connecting the grounding cable (FYEA v. 104)............................... 238
Figure 266 Exposing the wires........................................................................... 239
Figure 267 Connecting cables (FYEA v. 104).....................................................240
Figure 268 Closing the FYEA v. 104 lid.............................................................. 241
Figure 269 Flexi GPS Box (FYGD) front panel (v. 102)...................................... 243
Figure 270 Removing dummy unit......................................................................244
Figure 271 Fixing FYGD to core......................................................................... 245
Figure 272 1PPS connection.............................................................................. 245

Issue: 05 DN09142359 13
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 273 Connecting sync cable..................................................................... 246


Figure 274 Flexi Enhanced External GNSS Box (FYGE) front panel................. 247
Figure 275 Removing dummy unit......................................................................248
Figure 276 Fixing FYGE to core......................................................................... 249
Figure 277 1PPS connection.............................................................................. 249
Figure 278 Connecting sync cable..................................................................... 250
Figure 279 Connecting power cable................................................................... 250
Figure 280 FYGE installed inside of an FCOB................................................... 251
Figure 281 Removing four M5 screws and pulling out the dummy casing......... 252
Figure 282 Changing the dummy casing small plate position ........................... 253
Figure 283 Installing FYGE into the dummy casing............................................254
Figure 284 Reinserting and reinstalling the dummy casing with FYGE into the
FCOB................................................................................................254
Figure 285 Preparing the FYGE power cables................................................... 255
Figure 286 Connecting power cables to FYGE.................................................. 255
Figure 287 FYGG installed inside of an FCOB...................................................256
Figure 288 Removing four M5 screws and pulling out the dummy casing......... 256
Figure 289 Changing the dummy casing small plate position ........................... 258
Figure 290 Installing FYGG into the dummy casing........................................... 259
Figure 291 Reinserting and reinstalling the dummy casing with FYGG into the
FCOB................................................................................................260
Figure 292 Preparing the FYGG power cables...................................................261
Figure 293 Connecting power cables to FYGG.................................................. 261
Figure 294 Flexi Enhanced External GNSS Box (FYGE) front panel................. 262
Figure 295 1U casing on 19-inch rack................................................................ 262
Figure 296 1U casing fixing points......................................................................263
Figure 297 Connecting GNSS cabling................................................................263
Figure 298 Connecting sync cable..................................................................... 264
Figure 299 Connecting power cable................................................................... 264
Figure 300 Flexi Enhanced External GNSS Box (FYGE) front panel................. 265
Figure 301 FYGE installed on top of FSIH......................................................... 266
Figure 302 Connecting GNSS cabling................................................................267
Figure 303 Connecting sync cable..................................................................... 267
Figure 304 Connecting power cable................................................................... 268
Figure 305 Flexi Enhanced External GNSS Box (FYGE) front panel................. 268
Figure 306 Knocking off FSIH keyholes............................................................. 269
Figure 307 FYGE below FSIH............................................................................ 270
Figure 308 Connecting GNSS cabling................................................................271
Figure 309 Connecting sync cable..................................................................... 271
Figure 310 Connecting power cable................................................................... 272
Figure 311 Flexi Enhanced External GNSS Box (FYGE) front panel................. 272

14 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 312 FYGE 1U casing wall mounting points............................................. 273


Figure 313 OD External GNSS Enhanced Holdover (FYGG) front panel...........274
Figure 314 Removing dummy unit......................................................................275
Figure 315 Fixing FYGG to core.........................................................................276
Figure 316 Connecting GNSS cabling................................................................276
Figure 317 Connecting sync cable..................................................................... 277
Figure 318 Connecting power cable................................................................... 277
Figure 319 OD External GNSS Enhanced Holdover (FYGG) front panel...........278
Figure 320 1U casing on 19-inch rack................................................................ 278
Figure 321 1U casing fixing points......................................................................279
Figure 322 Connecting GNSS cabling................................................................279
Figure 323 Connecting sync cable..................................................................... 280
Figure 324 Connecting power cable................................................................... 280
Figure 325 OD External GNSS Enhanced Holdover (FYGG) front panel...........281
Figure 326 FYGG installed on top of FSIH......................................................... 282
Figure 327 Connecting GNSS cabling................................................................283
Figure 328 Connecting sync cable..................................................................... 283
Figure 329 Connecting power cable................................................................... 284
Figure 330 OD External GNSS Enhanced Holdover (FYGG).............................284
Figure 331 Knocking off FSIH keyholes............................................................. 285
Figure 332 FYGG below FSIH............................................................................286
Figure 333 Connecting GNSS cabling................................................................287
Figure 334 Connecting sync cable..................................................................... 287
Figure 335 Connecting power cable................................................................... 288
Figure 336 OD External GNSS Enhanced Holdover (FYGG) front panel...........288
Figure 337 FYGG 1U casing wall mounting points.............................................289
Figure 338 OD External GNSS Enhanced Holdover (FYGG) front panel...........290
Figure 339 Threading hose clamps.................................................................... 290
Figure 340 Installing FYGG on pole................................................................... 291
Figure 341 Threading hose clamps.................................................................... 292
Figure 342 Filter on the pole...............................................................................293
Figure 343 Hose clamps.....................................................................................294
Figure 344 Installing FCHB.................................................................................296
Figure 345 FSIH wall installation with two FCHBs..............................................297
Figure 346 FPIA delivery contents......................................................................299
Figure 347 FMAA delivery contents....................................................................300
Figure 348 FMCA delivery contents................................................................... 301
Figure 349 FMCH delivery contents................................................................... 302
Figure 350 FMCB delivery contents................................................................... 303
Figure 351 EMHA delivery contents................................................................... 305

Issue: 05 DN09142359 15
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Figure 352 EMHH delivery contents................................................................... 306


Figure 353 EMTA delivery contents.................................................................... 308
Figure 354 FMHA delivery contents................................................................... 309
Figure 355 FMTA delivery contents.................................................................... 310
Figure 356 FPMA delivery contents.................................................................... 311
Figure 357 FPAA delivery contents.................................................................... 312
Figure 358 FPBB delivery contents.................................................................... 313
Figure 359 FPDA delivery contents.................................................................... 314
Figure 360 FPAD delivery contents.................................................................... 314
Figure 361 FPAE delivery contents.................................................................... 315
Figure 362 FPFC delivery contents.................................................................... 316
Figure 363 FPFC delivery contents.................................................................... 318
Figure 364 FSES delivery contents.................................................................... 319
Figure 365 FSEP delivery contents.................................................................... 320
Figure 366 FODA delivery contents....................................................................321
Figure 367 FSEB delivery contents.................................................................... 322
Figure 368 GPS hardware.................................................................................. 324
Figure 369 FYEA delivery contents.................................................................... 325
Figure 370 FYGD delivery contents....................................................................326

16 DN09142359 Issue: 05
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

List of Tables
Table 1 Releases covered by the document................................................... 19
Table 2 Maximum sizes of conductors............................................................ 39
Table 3 End stage output DC cable thickness per number of FPAAs............. 40
Table 4 FPFC cable sizes..............................................................................110
Table 5 FPFC fuse settings........................................................................... 123
Table 6 FPFC cable sizes............................................................................. 127
Table 7 FPFC fuse settings........................................................................... 141
Table 8 Alarms supported by System Module variants................................. 210
Table 9 EACX connector I pin assignment (Sub-D37).................................. 216
Table 10 EACX connector II pin assignment (Sub-D37)................................. 217
Table 11 Screw terminal pin assignment.........................................................218
Table 12 Fire detector power screw terminal X4114 pin assignment.............. 220
Table 13 EAC cable (FTSI) wiring................................................................... 221
Table 14 GPS/GNSS pole mounting band cutting rule....................................226
Table 15 FYEA connections............................................................................ 232
Table 16 FYEA connections............................................................................ 239
Table 17 System Extension Kit (FSKA) delivery contents...............................298
Table 18 Flexi Pole Installation Kit (FPIA) delivery contents........................... 298
Table 19 Flexi Mounting Auxiliary Bracket (FMAA) delivery contents............. 299
Table 20 3U mounting covers (FMCA) delivery contents................................ 300
Table 21 Flexi 3U High Covers Mounting Covers Front/back (FMCH) delivery
contents............................................................................................ 301
Table 22 Flexi Mounting Covers Front and Back, 2U (FMCB), needed with Flexi
Power DC/ DC Module 24 V (FPDA)................................................303
Table 23 Flexi Module Casings for 3U modules (EMHA) delivery contents.... 304
Table 24 Flexi 3U Casing and High Covers F&B (EMHH) delivery contents.. 305
Table 25 Flexi Module Casings for 2U modules (EMTA) delivery contents.....307
Table 26 Flexi Side Covers (FMHA) delivery contents....................................308
Table 27 Flexi Side Covers (FMTA) delivery contents.................................... 309
Table 28 Flexi Power Module (FPMA) delivery contents.................................310
Table 29 FPAA power sub-module delivery contents...................................... 312
Table 30 FPBB power sub-module delivery contents......................................312
Table 31 24V Power Module (FPDA) delivery contents.................................. 313
Table 32 Flexi Power AC/DC sub-module (FPAD) delivery contents.............. 314
Table 33 Flexi Power AC/DC sub-module (FPAE) delivery contents.............. 315
Table 34 Flexi Power Distribution and Fuses Outdoor (FPFC) (Efore) delivery
contents............................................................................................ 315
Table 35 Flexi Power Distribution and Fuses Outdoor (FPFC) (AcBel) delivery
contents............................................................................................ 317
Table 36 Flexi System External OVP (FSES) delivery contents..................... 318

Issue: 05 DN09142359 17
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items

Table 37 Flexi System External OVP (FSEP) delivery contents..................... 319


Table 38 Flexi Fiber Optical Distribution unit (FODA) delivery contents......... 320
Table 39 Flexi System External Alarm Module (FSEB) delivery contents.......321
Table 40 GPS Mounting Kit (FYMA) delivery contents....................................322
Table 41 GPS GLONASS Receiver Antenna (FYGB) delivery contents.........323
Table 42 GPS cable deliveries (FYHA/FYHB/FTSE/FTSH/FTSM) ................ 323
Table 43 Flexi GPS Surge Protection Kit (FYEA) delivery contents................324
Table 44 GPS Box (FYGD) delivery contents................................................. 325
Table 45 Flexi Enhanced External GPS Box (FYGE) delivery contents..........326
Table 46 FYGE Mounting 1U Casing delivery contents.................................. 326
Table 47 OD External GNSS Enhanced Holdover (FYGG) delivery contents.327
Table 48 Flexi Filter B40 PassB=2305-2315MHz (FFNT) delivery contents... 327
Table 49 Flexi Filter B40 PassB=2350-2360MHz (FFNU) delivery contents...327
Table 50 Tools for installation.......................................................................... 328
Table 51 Torque values for the BTS................................................................ 329

18 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Summary of changes
Multiradio 10 Base Station Optional Items

Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.

This document is common for all Radio Access Technologies (RAT). You may find here
information about solutions that are not available or supported in a specific SW release
or RAT. Table Releases covered by the document lists all SW releases covered by the
content of this document. For features supported in your SW release, see respective
feature documentation chapter in the system library.

Table 1 Releases covered by the document
   
Product Release

GSM/EDGE (BSS) RG40 (BSS), GSM 16

WCDMA RAN RU50, RU50 EP1, WCDMA 16

Long Term Evolution RL70, FDD-LTE 15A, FDD-LTE 16

TD LTE RL55TD, TD-LTE 15A, TD-LTE 16

Changes between issues 04B (2015-12-03) and 05 (2016-02-17)
Information related to the following hardware items removed due to hardware phase-out:
• Flexi System External OVP (FSEC)
• Flexi Power AC/DC sub-module (FPAC)
• GPS Antenna Kit (FYGA)
• Flexi Rejection Filter B41 2.7-3Ghz (FFHS)

New chapter:
Installing FYGG inside of FCOB
Updated chapters:
Installing GPS GLONASS Receiver Antenna (FYGB)
• Graphics updated as per GPS Mounting Kit (FYMA) v. 102.

Contents of the GPS hardware deliveries
• Table GPS Mounting Kit (FYMA) delivery contents updated.

Changes between issues 04A (2015-10-29) and 04B (2015-12-03)
New chapter:
Installing Flexi GPS Surge Protection Kit (FYEA) v. 104
Updated chapter:

Issue: 05 DN09142359 19
   

Summary of changes Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Contents of the Flexi GPS Surge Protection Kit (FYEA) delivery
• Figure FYEA delivery contents updated as per v. 104.

Changes between issues 04 (2015-09-24) and 04A (2015-10-29)
Information related to Flexi Power Distribution and Fuses Outdoor (FPFC) v. 102
removed. The FPFC covered in this document is v. 203.
Updated chapters:
Installing Flexi System External Alarm (FSEB)
• Number of alarms supported updated.

20 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing System Extension Module
Multiradio 10 Base Station Optional Items

1  Installing System Extension Module
These instructions show how to install a System Extension Module and connect the
cabling.

Purpose
The System Extension Module is a System Module without a transmission sub-module.
The System Module can be used as a System Extension Module operating in a
baseband extension mode to add channel capacity. In this case, it is connected to the
System Module by connecting two optical cables and a DC cable.
These items are provided with Flexi System Extension Kit (FSKA) 471226A delivery that
includes:

• cable set assembly:
– 2 x optical cable (2 m (6.6 ft.))
– 1 x power cable (2 m (6.6 ft.))
– 4 x optical transceiver

• transmission dummy panel

The System Extension Module does not have a transmission sub-module. Instead, a
dummy transmission sub-module is installed to provide IP protection.

w NOTICE: Risk of damage to equipment. If you are reusing a Master System Module as
a System Extension Module, remove the transmission sub-module before installing it.

Before you start
The module itself is installed the same way as the other modules.

Procedure

1 Install the System Extension Module casing.
In stacked installations, the System Extension Module is installed on top of the
module stack.

2 Install the dummy panel on the top right corner of the System Extension
Module core.

a) Install the dummy panel:
1. Align the dummy panel with the guide pin in the System Module.
2. Push the dummy panel in place.
3. Fix the dummy panel with 4 x M5x25 screws.
4. Tighten to 2.2 Nm (1.6 ft-lb).

Issue: 05 DN09142359 21
   

Installing System Extension Module Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

w NOTICE: Risk of damage to equipment. Check that the ingress protection (IP) gasket
remains in its place and install the dummy panel on top of it to make sure that the
ingress protection works properly.

3 If at least one of your modules is an FSMF, connect the cabling as instructed in
Connecting Flexi Multiradio Extension System Module (FSMD/E) to the Master
System Module (FSMF) or Connecting Flexi Multiradio Extension System
Module (FSMF) to the Master System Module (FSMF) in the Cabling Flexi
Multiradio 10 Base Station document. If both of your modules are release 2
System Modules, proceed to step 4.

4 Connect one end of the DC cable to the System Extension Module DC
connector and the other end to the connector marked with EXT on the System
Module front panel.
Route the DC cable through cable entries. Fix any excess cable on the sides of the
module casings.

g Note:  Do not overload the power feeding from the Master System Module to Extension
Module, i.e. do not connect the RF Module power feeding from the Extension Module.
See Connecting external power feed in the Cabling Flexi Multiradio BTS [technology]
document.

5 Install the optical transceivers (two to the Master System Module and two to
the System Extension Module).
For information on installing optical transceivers for FSMC/D/E, see Connecting
internal optical cables in the Cabling Flexi Multiradio BTS [technology] document.

6 Connect an optical cable from the OPT1 connector to the OPT1 connector on
the System Extension Module.
Make sure that all connector seals are firmly in place.
Note that OPT1 and OPT2 from the Master System Module have to be connected to
OPT1 and OPT2 on the System Extension Module respectively.

7 Repeat for the second optical cable (OPT2 connectors).

22 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Pole Installation Kit (FPIA)
Multiradio 10 Base Station Optional Items

2  Installing Flexi Pole Installation Kit (FPIA)
These instructions show how to install a Flexi Pole Installation Kit (FPIA).

Purpose
Flexi Pole Installation Kit (FPIA) 471767A is used for installing the following auxiliary
units to a pole:

• Flexi System External Alarm (FSEB)
• Flexi System External OVP (FSES)
• Flexi System External OVP (FSEP)
• Flexi System External GPS Mediator (FSEG)
• Flexi GPS Surge Protection Kit (FYEA)
• Flexi GPS Box (FYGD)

The supported pole size is between 60 mm (2.4 in.) and 160 mm (6.3 in) in diameter.
The recommended torque value for fixing the FPIA is 5.0-8.0 Nm (3.7 - 5.9 ft-lb.).

Procedure

1 Install the auxiliary unit to the installation plate using four screws.
The installation orientation can be either horizontal or vertical depending on the
requirements of the auxiliary unit.

Figure 1 Example: installing FYEA on the installation plate

Issue: 05 DN09142359 23
   

Installing Flexi Pole Installation Kit (FPIA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

2 Thread the straining strap to the installation plate.

Figure 2 Threading the straining strap

24 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Pole Installation Kit (FPIA)
Multiradio 10 Base Station Optional Items

3 Install the installation plate to the pole with the straining strap.

Figure 3 Installing the FPIA to the pole

3 4

4 Tighten the straining strap around the pole.

Issue: 05 DN09142359 25
   

Installing Flexi Mounting Auxiliary Brackets (FMAA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

3  Installing Flexi Mounting Auxiliary Brackets
(FMAA)
Instructions for installing auxiliary units on Flexi Mounting Auxiliary Brackets (FMAA)
471657A.

Purpose
Flexi Mounting Auxiliary Brackets (FMAA) 471657A can be used to mount auxiliary units
on casings in pole, wall and stack configurations. The brackets are mounted on the
casing using the existing connection pin holes.

Figure 4 Flexi Mounting Auxiliary Brackets (FMAA)

Springwasher

The FMAA can be used with the following auxiliary units:

• Flexi System External Alarm (FSEB)
• Flexi GPS Surge Protection Kit (FYEA)
• Flexi System External OVP (FSES) (using two screws)
• Flexi System External OVP (FSEP) (using two screws)

The mounting holes for the most common installation position for each auxiliary unit are
labelled on the bracket.

26 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Mounting Auxiliary Brackets (FMAA)
Multiradio 10 Base Station Optional Items

Figure 5 Installing FMAA with FSEB

4 4
3 3

Issue: 05 DN09142359 27
   

Installing Flexi Mounting Auxiliary Brackets (FMAA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Procedure

1 Remove the four connection pins from the casing on which the FMAA is to be
installed.

2 Align the outer holes of each bracket with the connection pin holes.

3 Use the M5 X 10 screws and washers to mount each bracket to the casing.

4 To mount the auxiliary unit on the brackets, see the following installation
instructions:

• Installing Flexi System External OVP (FSES)
• Installing Flexi System External OVP (FSEP)
• Installing Flexi System External Alarm (FSEB)
• Installing Flexi GPS Surge Protection Kit (FYEA)

28 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Mounting Covers (FMCA/FMCH/FMCB)
Multiradio 10 Base Station Optional Items back

4  Installing Flexi Mounting Covers
(FMCA/FMCH/FMCB) back
These instructions show how to install Flexi Mounting Covers (FMCA/FMCH/FMCB) at
the back of Flexi modules.

Purpose
Flexi Mounting Covers for Back and Front 3U (FMCA) 470239A, Flexi 3U High Covers
Mounting Covers Front/back (FMCH) 473186A and Flexi Mounting Covers for Back and
Front 2U (FMCB) 470332A provide IP20 protection for core modules. Install the back
covers before installing the modules.
Note that some RF Module variants are delivered without a casing. If also optional front
and back covers are needed, order Flexi Module Casing (EMHA) for 3 height units (3U)
470316A or Flexi 3U Casing and High Covers F&B (EMHH) 473187A.
For information on casing and cover kits need for modules, see Appendix Casing and
cover kits need for Flexi Multiradio units in Installing Flexi Multiradio Base Station and
Flexi Multiradio 10 Base Station Modules in Cabinets.

f CAUTION! Risk of personal injury.
Rotating fan blades can cause personal injury. If Flexi BTS modules are not installed in
a cabinet, back covers must be used during operation for safety reasons and should
only be removed temporarily for maintenance.

Before you start

t Tip:  When there is no risk of dropping the covers, maintenance straps are not needed.

Maintenance straps can be attached to both ends of the module casing.

t Tip:  Make sure that the LEDs turn on before installing the front covers.

Procedure

1 Thread the longer loop of the maintenance strap around the grill rib.
To secure the strap firmly in place use the rib with the wall.

Issue: 05 DN09142359 29
   

Installing Flexi Mounting Covers (FMCA/FMCH/FMCB) Installing Flexi Multiradio Base Station and Flexi
back Multiradio 10 Base Station Optional Items

Figure 6 Fixing maintenance strap to back cover

Ribwithawall

2 Route the end with the snap hook through the exposed loop and tighten the
loop.

3 Engage the snap hook to the casing.
Use the fixing point shown in Figure 7: Snap hook fixing point.

Figure 7 Snap hook fixing point

30 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Mounting Covers (FMCA/FMCH/FMCB)
Multiradio 10 Base Station Optional Items back

4 Install the back cover in the rear of the module.
Make sure that the maintenance strap remains behind the plastic wall.

Figure 8 Maintanance strap

5 Fix the back cover screws (Torx T25) and tighten to 2.5 Nm (1.8 ft-lb).

Issue: 05 DN09142359 31
   

Installing Flexi Mounting Covers (FMCA/FMCH/FMCB) Installing Flexi Multiradio Base Station and Flexi
front Multiradio 10 Base Station Optional Items

5  Installing Flexi Mounting Covers
(FMCA/FMCH/FMCB) front
These instructions show how to install Flexi Mounting Covers (FMCA/FMCH/FMCB) on
the front panel of Flexi modules.

Purpose
Flexi Mounting Covers for Back and Front 3U (FMCA) 470239A, Flexi 3U High Covers
Mounting Covers Front/back (FMCH) 473186A and Flexi Mounting Covers for Back and
Front 2U (FMCB) 470332A provide IP20 protection for core modules.
Note that some RF Module variants are delivered without a casing. If also optional front
and back covers are needed, order Flexi Module Casing (EMHA) for 3 height units (3U)
470316A or Flexi 3U Casing and High Covers F&B (EMHH) 473187A.
For information on casing and cover kits need for modules, see Appendix Casing and
cover kits need for Flexi Multiradio units in Installing Flexi Multiradio Base Station and
Flexi Multiradio 10 Base Station Modules in Cabinets.

f CAUTION! Risk of personal injury.
The front panels of the modules are hot during operation. If Flexi BTS modules are not
installed in a cabinet, front covers must be used during operation for safety reasons and
should only be removed temporarily for maintenance.

Before you start

t Tip:  When there is no risk of dropping the covers, maintenance straps are not needed.

t Tip:  Make sure that the LEDs turn on before installing the front covers.

Procedure

1 Thread the longer loop of the maintenance strap around the grill rib on the
front cover.

Figure 9 Fixing maintenance strap to front cover

32 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Mounting Covers (FMCA/FMCH/FMCB)
Multiradio 10 Base Station Optional Items front

2 Route the end with the snap hook through the exposed loop and tighten the
loop.

3 Engage the hook to the hole on the external cable entry.

Figure 10 Hook fixing point

4 Install the front cover and tighten the screws (Torx 25) to 2.5 Nm (1.8 ft-lb.).

Issue: 05 DN09142359 33
   

Installing Flexi Side Covers (FMHA/FMTA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

6  Installing Flexi Side Covers (FMHA/FMTA)
These instructions show how to install Flexi Side Covers (FMHA/FMTA) on the sides of
module casings.

Purpose

Figure 11 Flexi Side Covers 3U (FMHA)

Removableknockout

You can use the optional side covers to hide excess cabling on the side of stack or pole
configurations. They are recommended whenever it is necessary to protect cabling from
birds or rodents. Side covers are not required for weather protection.
Flexi BTS Side Covers FMTA for 2 height units (2U) 471523A and Flexi BTS Side
Covers FMHA for 3 height units (3U) 471524A must be ordered separately. Note that
they are not compatible with Flexi 3U Casing and High Covers F&B (EMHH).

Procedure

1 Remove the knockouts from the side cover as required by the position of the
side cover.

• For all external side covers on the right side, remove the back knockout.
• For the top internal side cover on the left side, remove the bottom knockout.
• For the bottom internal side cover on the left side, remove the top knockout.
• For the remaining internal side covers on the left side, remove the top and
bottom knockouts.

34 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Side Covers (FMHA/FMTA)
Multiradio 10 Base Station Optional Items

2 Pre-thread the M5x10 screws into the side cover.

3 Position the side cover over the cable support plate so that the side cover
screws are aligned with the plate fixing points, and tighten the screws.

g Note:  If you are using a plastic cable support plate, fix the side cover with self-tapping
5x10 PT screws. If you are using a metallic cable support plate, fix the side cover with
M5x10 screws.

4 Remove the pre-installed screws from the front cover.

5 Position the side cover front pieces over the module front cover so that each
side cover front piece hole is aligned with the module front cover holes.

6 Pre-thread M5 screws that came with the accessory bag through both front
covers so that the side cover front piece is connected to the module front
cover.

g Note:  The M5 screws that came in the accessory bag have threading closer to the end
of the screw. The M5 screws that came pre-installed on the module front covers have
threading closer to the middle and do not work with the side covers.

7 Align the module front cover screws with the cable entry fixing points and
tighten the screws.

8 Repeat steps 2-7 for each casing.

g Note:  On sites where birds or rodents are a concern, it is recommended that any
cabling coming out the side cover kit is protected with conduit. Use any suitable
standard conduit for that purpose. Make sure that the conduit is securely locked in
position as close to the IP seals as possible.

Issue: 05 DN09142359 35
   

Installing Flexi Side Covers (FMHA/FMTA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Result

Figure 12 Stack installation with cable tunnels

36 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

7  Installing Flexi Power Module (FPMA)

7.1  Installing Flexi Power Module (FPMA)
These instructions show how to install and connect the cabling of Flexi Power Module
(FPMA).

Purpose
Flexi Multiradio BTS uses 48 VDC power. In a BTS site with AC feed only, a Flexi Power
Module (FPMA) 470139A is required for converting the AC power to DC power before
feeding the DC power to the System Module.
Flexi Power Module (FPMA) consists of mechanics, AC terminal and four slots for
AC/DC sub-module (FPAA) 470140A or battery sub-module (FPBB) 472113A.
The FPMA can include:

• two FPAAs and two FPBBs
• four FPAAs
• one FPAA and three FPBBs. Remember to take the charging current into account
when dimensioning the rectifiers and batteries.
• one FPAA and three free slots for expansion.

w NOTICE: Incorrect cables and seals may not provide appropriate ingress protection.
Use only tested IP65 class outdoor cables with seals provided by Nokia. This is
required for both indoor and outdoor installations, including the outdoor cabinet.

The FPMA must be located close enough to the System Module so that the alarm cable
and DC power cables reach the appropriate connectors. This also applies to the System
Extension Module (DC power cables only).
Two FPMAs can be installed in a stack to support FPAA and FPBB operating in parallel.
In a stacked dual FPMA installation, the FPAAs and FPBBs need to be interleaved per
rack. Do not install rectifiers in one rack and batteries in another.

Issue: 05 DN09142359 37
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 13 Two FPMAs stacked

ACdistribution FPXX FPXX FPXX FPXX

75Ato
ACdistribution FPXX FPXX FPXX FPXX
SystemModule

If your configuration includes a System Extension Module, utilize the additional ground
lugs attached to the DC cable harness. Tighten the nuts to 14 Nm (10 ft-lb.).
By default, the DC output voltage of the FPMA is floating nominal 48 VDC, however, it
can also be positive grounded. This can be implemented by using a branch connector in
an additional connection box (see Figure 14: Positive grounding). In this solution, the +
wire between the FPMA and System Module is cut, and grounding to the BTS site
ground bar is done with an additional grounding cable (the cross-section of which must
be the same as that of the + wire).

38 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

Figure 14 Positive grounding

The maximum diameter of the AC power feed cable is 24 mm (0.9 in). The maximum
sizes of conductors that the incoming AC terminals can accommodate are presented in
Table 2: Maximum sizes of conductors.

Table 2 Maximum sizes of conductors
   
Rated connecting capacity Value

Rigid (solid or stranded) up to 16 mm2 (6 AWG)

Flexible up to 10 mm2 (7 AWG)

Flexible with ferrule (without plastic up to 10 mm2 (7 AWG)
sleeve)

Flexible with ferrule (with plastic sleeve) up to 10 mm2 (7 AWG)

Flexible with TWIN ferrule up to 6 mm2 (9 AWG)

t Tip:  It is recommended that the FPMA be pre-installed before installing it on the plinth.

If applicable, multiple FPMAs can be installed to FPMA unit to support FPAA and FPBB
connection in parallel. A maximum of two DC cables can be installed together at each
output terminal. This limitation is caused by:

• The output current from the FPMA where two with more than 4 FPAAs are combined
would exceed the safety limits for the thickness of the DC cables provided in the
delivery.
• The safety rubber boots provided in the delivery can accommodate up to two DC
cables per terminal.
• The DC output terminal bolt length can accommodate up to two DC cables per
terminal.

Issue: 05 DN09142359 39
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figures FPMA provisioning for configurations with one FPMA through FPMA provisioning
for configuration with new and old version FPMA show examples of FPMA provisioning
based on the number of FPMAs.

Figure 15 FPMA provisioning for configurations with one FPMA

Circuit AC FPMA 48VDC System


break (101->) Module

Figure 16 FPMA provisioning for configurations with two FPMAs

Circuit AC FPMA 48VDC System


break (204) Module

Circuit AC FPMA 48VDC


break (204)

Figure 17 FPMA provisioning for configurations with new and old version FPMA

Circuit AC FPMA 48VDC System


break (204) Module

Circuit AC 48VDC
FPMA
break (101-103)

• When FPMAs are installed in parallel, the DC output cables should be installed
together at the FPMA closest to the System Module.
• When these two FPMAs have more than four FPAAs, two additional cable lugs are
required for the second stage FPMA output. These cable lugs are not included in the
delivery and must be sourced locally, choose appropriate thickness of the DC cables
based on the number of FPAAs. See Table 3: End stage output DC cable thickness
per number of FPAAs for details.
Table 3 End stage output DC cable thickness per number of FPAAs
     
The quantity of FPAAs in Maximum output current End stage output cable
FPMA configuration recommendation
thickness

Fewer than 4 FPAAs 74 A Default (25 mm2) (4 AWG)

5 FPAAs 92.5 A 35 mm2 (2 AWG)

6 FPAAs 111 A 50 mm2 (1 AWG)

7 FPAAs 129.5 A 50 mm2 (1 AWG)

8 FPAAs 148 A 50 mm2 (1 AWG)

40 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

• When there are 8 FPAAs in FPMAs in parallel mode, two additional 50 mm2 (1 AWG)
cables are required for the end stage FPMA.
• New version FPMAs can be compatible with the old version FPMAs as old version is
used as the first stage.
• When FPMAs are operated in parallel the alarm connection between FPMA and
System Module can be made in alternative ways. See Figure 18: FPMA provisioning
for configurations with two FPMAs. Black line routing shows the primary connection
and the black dotted line the alternative connection.

Figure 18 FPMA provisioning for configurations with two FPMAs

AC DC
Alternative
connection
System
Module

AC DC

Before you start
Check that the mains breaker is off.
Take the cable harness from the accessory bag and tighten the two M10 nuts to 14 Nm
with a torque wrench.

Figure 19 FPMA cable harness nuts

Issue: 05 DN09142359 41
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Procedure

1 Install the Flexi Power Module (FPMA) and ground it.

Figure 20 Connecting grounding cable and installing DC cable harness

SystemModule
1

2 Install the DC cable harness inside the FPMA, on the right-hand side.
Fix with one screw (note that if cable entries are used with the FPMA, the same
screw also holds the cable entry in place).

Figure 21 Installing FPMA DC cable harness

42 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

3 Remove the ingress protection plate by undoing the screws holding the plate
in place.

Figure 22 Removing the ingress protection plate

System
Module
Sy
3 ste
m
Mod
ule

4 Undo the screw from the top left corner of the AC terminal enclosure and pull it
out.

Figure 23 Removing the AC terminal enclosure

System
Module

Issue: 05 DN09142359 43
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

5 Remove the cover of the AC terminal enclosure by undoing the four screws.

6 Detach the AC terminal from the enclosure by undoing the two screws at the
bottom of the enclosure.

Figure 24 Detaching the AC terminal

7 Route the AC cable through the round hole in the top left corner of the ingress
protection plate.

Figure 25 Routing the AC cable through the ingress protection plate

8 Route the AC cable through the cable clamp on the AC terminal.

9 Make the AC connection. Tighten the screws to 1.8 Nm (1.3 ft-lb.).

f WARNING! Danger of lethal voltages.
Switch off the AC power breaker before connecting the AC cable.

44 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

See figures Figure 26: Single phase connection 230 V AC, Figure 27: 3-phase star
connection 230 V AC, Figure 28: 3-phase delta connection, base voltage 100-120 V
AC (200-240 V AC potential difference), and Figure 29: 3-phase delta connection 110
V AC for AC connection alternatives. The alternatives are also shown on the label on
the inside of the AC terminal enclosure cover. The colors of the wires may vary
depending on the country.

Figure 26 Single phase connection 230 V AC

g Note:  For a 3-phase star connection, remove the bridge by loosening the screws
behind L1-L3.

Figure 27 3-phase star connection 230 V AC

g Note:  For a 3-phase delta connection, remove the bridges by loosening the screws
behind L1-L3 and N1-N3.

Issue: 05 DN09142359 45
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 28 3-phase delta connection, base voltage 100-120 V AC (200-240 V AC
potential difference)

g Note:  For a 3-phase delta connection (110 V AC) connect the bridges for terminals L1-
L3 and N1-N3. See Figure 29: 3-phase delta connection 110 V AC.

Figure 29 3-phase delta connection 110 V AC

10 If required, install a Surge Protection Device (SPD).
FPMA supports the use of surge protection device (SPD), if it is required.

46 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

11 Reinstall the AC terminal inside the enclosure and fix the two screws at the
bottom.

12 Reinstall the cover of the enclosure and fix the four screws.

13 Push the AC terminal plate back into its slot and fix it with one screw in the top
left corner.

Figure 30 Installing sub-modules

Systteem
mM
Moodduule
le
15

13
14

14 Install the FPAA sub-modules required by your configuration.
The first or only FPAA must always be installed in the leftmost module slot. If there
are empty slots, they must always be on the right.
Note that if you are installing FPMA in a third-party cabinet, it may be necessary to
change the FPAA cooling fan airflow direction from back-to-front to front-to-back.
This is possible with FPAA 470140A.204 version. See the steps below on how to do
this on Efore and AcBel FPAAs.
a) Remove the fan fixing screws.
b) Flip the fan so that the fan label is visible.
c) Fix the fan fixing screws back.

Issue: 05 DN09142359 47
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 31 Changing the FPAA fan airflow direction (AcBel)

3
1

Figure 32 Changing the FPAA fan airflow direction (Efore)

1
2
1

1 1 3

48 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

15 Fix the FPAA screws.

16 Connect the AC cable from the FPAA to the FPMA AC terminal.

Figure 33 Connecting the AC cable

System
Modu
le

16

17

17 If you are using battery backup, install the FPBB sub-modules required by your
configuration.
Follow the same mechanical procedure as in FPAA installation.

18 If alarms from the FPMA to the System Module are needed, connect the alarm
cables.

Figure 34 Connecting the alarm cables

18a

18c
18b

Issue: 05 DN09142359 49
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

w NOTICE: Connect the FPBB alarm cable to the FPAA, otherwise the FPBB LED does
not work.

a) Remove the ingress protection from the alarm cable connectors in FPAA and
FPBB.
b) Chain the sub-modules together with the alarm cable from left to right.
c) Connect the alarm cable from one of the sub-modules to the System Module.
See Figure 18: FPMA provisioning for configurations with two FPMAs for more
information.

19 Connect the DC cables to all the sub-modules.

Figure 35 Connecting the DC cables

19

20 Reinsert the ingress protection plate with cables routed through it as follows:

a) Fix the grounding cable.
b) Fix the screws.

50 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

Figure 36 Replacing the ingress protection plate

20b

20a

21 If applicable, install the cable entries.

Figure 37 Installing cable entries

21
21

22 If applicable, install a second FPMA on top of the first FPMA to support FPAA
and FPBB connection in parallel.

a) Cut the rubber boots of the DC cable harness (included in the accessory bag).
Note that the cable terminals are included in the FPMA.

Issue: 05 DN09142359 51
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 38 Installing second FPMA

b) Remove the rubber boots.
c) Connect the power output cables ot the first FPMA to the DC cable harness of
the second FPMA.

52 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

Figure 39 Installing second FPMA

d) Install the DC cable harness to the FPMA.
e) Install the FPAA and/or FPBB sub-modules and connect the DC cable harness.

Issue: 05 DN09142359 53
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

23 Route the DC power feed cables through the cable entries and connect them
from the FPMA to the System Module.

Figure 40 Connecting the DC power feed cable (FSMF)

54 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

24 Check that the cable connectors' seal caps are firmly in place.

25 Connect the mains power.

26 Power up the site.
Make sure that the FPAA LED is yellow at this point.

27 Turn on the FPAA and FPBB by pushing the switch.
Make sure that the FPAA LED is stable green and the FPBB LED is green and
blinking slowly (charging).
To maximise the FPBB life-time, the charging current is limited. Therefore, it can take
up to 12 hours to fully charge an empty FPBB.

28 If applicable, install the FPMA module covers.
See Installing Flexi Mounting Covers (FMCA/FMCH/FMCB) back and Installing Flexi
Mounting Covers (FMCA/FMCH/FMCB) front for instructions.
If installing the front cover is required, fix the air deflector plate to the front cover first.

7.2  Powering an RF Module with a single FPMA
equipped with one rectifier
These instructions show how to connect an RF Module to a single FPMA that has one
rectifer (FPAA) installed.

Before you start
Perform the FPMA AC and rectifier cabling as instructed in Installing Flexi Power Module
(FPMA).

Procedure

1 Connect the power cable to the RF Module.
Use the longest cable from the DC cable harness to connect the closest RF Module
directly from FPMA.

Issue: 05 DN09142359 55
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

2 Complete the rest of the power cabling depending on the configuration.
See Figure 41: Example configuration for an example configuration where the
bottommost RF Module has been powered directly from FPMA using the longest
cable of the DC cable harness.

Figure 41 Example configuration
SystemModulepowercables

RFModule

PowerModule

Plinth

7.3  Powering an RF Module with a single FPMA
equipped with 4 rectifiers/batteries
These instructions show how to connect an RF Module to a single FPMA that has four
rectifiers/batteries installed.

Before you start
Perform the FPMA AC and rectifier/battery cabling as instructed in Installing Flexi Power
Module (FPMA).

Procedure

1 Remove the Multi-Beam connector from RF Module power cable.
Remove the connector from the other end of cable 994808.

56 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

Figure 42 Connector removed from cable 994808

2 Strip the power cable.
Strip the power cable approx. 120 - 150 mm (4.7. - 5.9 in.).

Figure 43 Stripped power cable

Issue: 05 DN09142359 57
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

3 Detach the DC cable harness from FPMA.

Figure 44 Detached DC cable harness

4 Remove the IP boots from the connectors.

Figure 45 Removed IP boots

58 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

5 Remove the cable terminals, washers and nuts

Figure 46 Removed cable terminals, washers and nuts

6 Cut the IP boot heads off.

Figure 47 IP boot heads

Issue: 05 DN09142359 59
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

7 Cut an entry through the IP boots.
Use, for example, a screwdriver to cut an entry to the IP boots. See Figure 48:
Cutting the IP boots.
Be careful not to damage the IP boots.

Figure 48 Cutting the IP boots

8 Route the RF Module power cables through the IP boots.

Figure 49 Routing the power cables through the IP boots

60 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

9 Strip the + and - wires approx. 15 mm (0.6 in.).

Figure 50 Stripping the - cable

10 Attach the protection tubes to the + and - wires.

Figure 51 Attaching the protection tubes

Issue: 05 DN09142359 61
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

11 Fix the cable terminals to + and - wires.

Figure 52 Cable terminals attached

12 Fix the protection tubes using plastic insulation bands.

Figure 53 Using plastic insulation bands

62 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

13 Fix the cables to the DC cable harness DC connectors and tighten the two M10
nuts to 14 Nm with a torque wrench.

Figure 54 Fixing the power cables to DC connectors

14 Reattach the IP boots.

Figure 55 Attaching the IP boots

15 Fix the DC cable harness back to the FPMA.

16 Connect the RF Module to FPMA.
See Figure 56: DC cable harness power cables for information on module
connections.

Issue: 05 DN09142359 63
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 56 DC cable harness power cables

7.4  Powering two System Modules with a single FPMA
These instructions show how to connect two System Modules to a single FPMA.

Purpose
A single FPMA installation can provide power to two System Modules.

Before you start
Perform the FPMA AC and rectifier/battery cabling as instructed in Installing Flexi Power
Module (FPMA).

Procedure

1 Detach the DC cable harness from FPMA.

2 Cut the IP boots of the DC cable harness and remove them.
See steps a) and b) in Figure 57: Removing the IP boots.

64 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

Figure 57 Removing the IP boots

3 Connect power cable 995069 to the DC cable harness.
See step c) in Figure 58: Connecting power cables. Cable 995069 must be
purchased separately.

Issue: 05 DN09142359 65
   

Installing Flexi Power Module (FPMA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 58 Connecting power cables

4 Install the DC cable harness back to FPMA.
See step d) in Figure 58: Connecting power cables.

5 Connect the System Module power cables.
Figure 59: Powering two System Modules with one FPMA shows the power
connection with two System Modules and a single FPMA. Note that two FPMA
parallel operation is not possible in this configuration.

66 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Module (FPMA)
Multiradio 10 Base Station Optional Items

Figure 59 Powering two System Modules with one FPMA

SystemExtension
Module(optional)

RFModule3

RFModule2

Transmission
sub-module

SystemModule

RFModule1

PowerModule
(optional)

Plinth

ConnectionforfirstSM
ConnectionforsecondSM

Issue: 05 DN09142359 67
   

Installing Flexi Power DC/DC Module 24V (FPDA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

8  Installing Flexi Power DC/DC Module 24V
(FPDA)
These instructions show how to install and connect the cabling of Flexi Power DC/DC
Module 24V (FPDA).

Purpose
Flexi Power DC/DC Module (FPDA) 470067A is an isolated 2U-high DC/DC Power
Module that converts nominal 24 V DC input voltage to 48 V DC nominal output voltage
and 2 kW power.

Figure 60 Flexi Power DC/DC Module 24V (FPDA) front panel

DCInputcabling Alarmcabling DCOutputcabling

LED

GND

When the BTS power load is more than 2 kW, multiple FPDAs can be installed in
parallel. When FPDAs are used in parallel, a maximum of two DC cables can be installed
together at each output terminal. This limitation is caused by:

• The output current from the FPDA where all three are combined would exceed the
safety limits for the thickness of the DC cables provided in the delivery.
• The safety rubber boots provided in the delivery can accommodate up to two DC
cables per terminal.
• The DC output terminal bolt length can accommodate up to two DC cables per
terminal.

Figures Figure 61: FPDA provisioning for configurations with one FPDA, Figure 62:
FPDA provisioning for configurations with two FPDAs, Figure 63: FPDA provisioning for
configurations with three FPDAs and two System Modules (sample 1), Figure 64: FPDA
provisioning for configurations with three FPDAs and two System Modules (sample 2),
Figure 65: FPDA provisioning for configurations with three FPDAs and one System
Module (sample 3), and Figure 66: FPDA provisioning for configurations with four FPDAs
and two System Modules show examples of FPDA provisioning based on the number of
FPDAs.

Figure 61 FPDA provisioning for configurations with one FPDA

Circuit 24VDC 48VDC System


Breaker
FPDA
Module

68 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power DC/DC Module 24V (FPDA)
Multiradio 10 Base Station Optional Items

Figure 62 FPDA provisioning for configurations with two FPDAs

Circuit 24VDC

Breaker
FPDA
48VDC

Circuit 24VDC 48VDC System


Breaker
FPDA
Module

g Note:  When FPDAs are installed in parallel, the DC output cables should be installed
together at the FPDA closest to the System Module.

g Note:  Two additional 4 AWG (25 mm2) cable lugs are required for each additional
FPDA used in parallel. These lugs are not included in the delivery and must be sourced
locally.

w NOTICE: Risk of damage to equipment. When FPDAs are installed in parallel and a
power failure occurs in a DC line, the input voltage to the System Module is likely to
drop below the acceptable level. If an FPDA is overloaded with power, then the unit
shuts itself down.

Figure 63 FPDA provisioning for configurations with three FPDAs and two System
Modules (sample 1)

Circuit 24VDC 48VDC System


Breaker
FPDA
Module

Circuit 24VDC

Breaker
FPDA
48VDC

Circuit 24VDC 48VDC System


Breaker
FPDA
Module

g Note:  In the example in Figure 63: FPDA provisioning for configurations with three
FPDAs and two System Modules (sample 1), the power draw from the System Module
to the single FPDA cannot exceed 2 kW.

Issue: 05 DN09142359 69
   

Installing Flexi Power DC/DC Module 24V (FPDA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 64 FPDA provisioning for configurations with three FPDAs and two System
Modules (sample 2)

Circuit 24VDC 48VDC System


Breaker
FPDA
Module
48VDC

Circuit 24VDC

Breaker
FPDA
48VDC

Circuit 24VDC 48VDC System


Breaker
FPDA
Module
Figure 65 FPDA provisioning for configurations with three FPDAs and one System
Module (sample 3)

Circuit 24VDC 48VDC System


Breaker
FPDA
Module
48VDC

Circuit 24VDC

Breaker
FPDA
48VDC

Circuit 24VDC

Breaker
FPDA

g Note:  In Figure 65: FPDA provisioning for configurations with three FPDAs and one
System Module (sample 3), FPDA provisioning requires four pairs of double rubber
boots (822862) for safety. The standard delivery for this configuration only includes
three pairs of double boots. An extra pair must be ordered as a spare part for combining
the DC cables at each System Module input terminal.

70 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power DC/DC Module 24V (FPDA)
Multiradio 10 Base Station Optional Items

Figure 66 FPDA provisioning for configurations with four FPDAs and two System
Modules

Circuit 24VDC

Breaker
FPDA 48VDC

Circuit 24VDC 48VDC System


Breaker
FPDA
Module

Circuit 24VDC

Breaker
FPDA 48VDC

Circuit 24VDC 48VDC System


Breaker
FPDA
Module

The FPDA is delivered with two sets of rubber boots:

• one set accommodates cable thickness of 35-50 mm2 (2 to 1/0 AWG) for 24 V DC
input. Required cable thickness depends on the distance and voltage drop from the
external 24 V DC power supply.
• the other set accommodates up to two 25 mm2 (4 AWG) cables per terminal for 48 V
DC output to the System Module.
These boots can be used for single or dual DC cables at each power terminal. Dual
usage is required for pairing (chaining) cables when two FPDA modules are used in
parallel as shown in Figure 67: Parallel FPDAs with paired (chained) DC cables and
boots.

The FPDA(s) must be located close enough to the System Module so that the alarm
cable reaches the appropriate connectors.

Issue: 05 DN09142359 71
   

Installing Flexi Power DC/DC Module 24V (FPDA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 67 Parallel FPDAs with paired (chained) DC cables and boots

ToSystem
Module
In FCIA and FCOA installations, the FPDA is installed directly to the rack without cable
entries and plinth.

Before you start
• Check that the 24 V DC supply system is switched off. In addition, make sure that its
AC mains circuit breaker (and also the battery circuit breaker if the 24 V DC supply
system is a battery back-up system) is switched off.
• When installing the FPDA in cabinets, detach the connection pins, support plates
and cage nuts the same way as with the FPMA. See figure Installing FPMA inside
FCOA steps 1 to 4 in Installing Flexi Power Module (FPMA) in FCOA.

w NOTICE: Incorrect cables and seals may not provide appropriate ingress protection.
Use only tested IP65 class outdoor cables with seals provided by Nokia Networks. This
is required for both indoor and outdoor installations, including the outdoor cabinet.

w NOTICE: Risk of damage to equipment. Connector seals or boots must be installed at
all times, whether the site is active or not.

72 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power DC/DC Module 24V (FPDA)
Multiradio 10 Base Station Optional Items

Procedure

1 Install the FPDA and (in cabinet installation) fix the module to the cabinet with
screws.

2 Attach the cable entries using two screws (in stack, wall and pole
installations).

Figure 68 Fixing cable entries

3 Make sure that the power switch on the front panel is in the stand-by position.

4 Connect the grounding cable to the plinth (in stack, wall and pole
installations).

Figure 69 Connecting grounding cable to plinth

Issue: 05 DN09142359 73
   

Installing Flexi Power DC/DC Module 24V (FPDA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

5 Remove the bolts and washers from the DC output terminals.

Figure 70 Connecting DC output cables to FPDA

6 Insert the rubber boots to the DC output cables.
If the cable is 50 mm2 (1 AWG), cut the rubber boot to fit the cable.
If two FPDAs are used in parallel, cut the sealed hole on the DC output boots.

7 Route the DC output cables through the cable entry (in stack, wall and pole
installation).
Use the top right entry hole for the V48N- cable and bottom right entry hole for the
V48RTN+ cable.

74 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power DC/DC Module 24V (FPDA)
Multiradio 10 Base Station Optional Items

8 Connect the V48N- cable to the minus terminal and V48RTN+ cable to the plus
terminal in the FPDA module.

9 Tighten the bolts to 10.0 - 14.0 Nm (7.0 - 9.8 ft-lb) Nm.

10 Pull the rubber boots over the DC output terminals.

11 Connect the DC output cables to the System Module.
Note that there is a risk of short circuit. Connect the power cable as instructed.

12 Remove one of the alarm connector seals on the front panel of the FPDA and
connect the alarm cable.
Make sure that you are inserting the cable connector as instructed in Figure 71:
Connecting alarm cable.
With FSMF, use an RJ45 cable with an open end (e.g. FTCR OD cable RJ45 Cat5e
15 m (471408A)). FTSI EAC Cable HDMI - D37 2.5 m (472578A) or FSAF EAC
cable HDMI - D37 50 m (472695A) can be used, however, a Flexi System External
Alarm (FSEB) enclosure is required between the FSMF and FPDA.

Figure 71 Connecting alarm cable

ToSystemModuleorFSEB

FSEB

FTSI/FSAF

Issue: 05 DN09142359 75
   

Installing Flexi Power DC/DC Module 24V (FPDA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

13 Check that the power switch on the front panel of the FPDA is still in the stand-
by position.

14 Make sure that the 24 V DC supply for the FPDA is de-energised and connect
the DC input cables similarly as the DC output cables.
Connect the minus wire to the minus terminal and the plus wire to the plus terminal.
Note that the DC input cables are not included in the delivery. The length and
thickness of the DC input cables must be defined based on the distance to the 24 V
DC power source. The maximum thickness of a DC input cable that can be installed
to the FPDA is 50 mm² (1/0 AWG).

15 Connect the AC mains power for the 24 V DC supply system.

16 Connect the 24 V DC supply (and the battery circuit breaker if the 24 V DC
supply system is a battery back-up system).
Make sure the LED is yellow.

17 Switch on the power by pushing the power switch on the front panel of the
FPDA.
Make sure the LED is green.

18 Make sure that the unused connectors are covered with seal caps.
Make sure that the seal caps are inserted correctly.

19 Install the module front cover (in stack, wall and pole installations).

76 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Principles for installing Flexi Power Rectifier (FPRx) in
Multiradio 10 Base Station Optional Items Flexi Multiradio BTS configurations

9  Principles for installing Flexi Power Rectifier
(FPRx) in Flexi Multiradio BTS configurations
The following locations for installing the Flexi Rectifier Module (FPRB) CS7000030 in
Flexi Multiradio BTS configurations are recommended for ease of future expansion. The
FPRx can be installed anywhere in a stack or cabinet provided that the 2 m (6.6 ft) alarm
cable can be connected between the FPRx and System Module.
For installation and cabling instructions, see Flexi Power Rectifier Product
Documentation in Product Information Center.
FCIA installations
• For installations in Flexi Cabinet for Indoor (FCIA) without batteries, the
recommended location is at the top of the cabinet, near the cabinet roof. This helps
reduce the amount of cabling routed along the sides of the cabinet.
• For FCIA installations with batteries, the recommended location is near the bottom of
the cabinet, in the next available rack space above the batteries.
FCOA installations
For installations in Flexi Cabinet for Outdoor (FCOA):

• If the System Module is in the top vertical rack, install the FPRx on the lower vertical
rack, ensuring all cable entries come from the bottom of the module.
• If the System Module is in the horizontal rack, install the module in the top vertical
rack.
• If the System Module and System Extension Module are installed in both vertical
racks, install the module in either the top or bottom of the horizontal rack, depending
on whether the top or bottom cable entry is used for the external power feed.
• For FCOA installations with Flexi Cabinet Site Support Module (FCSA), the FPRx is
installed inside the FCSA. In that case, the AC interface support on the FCSA ceiling
needs to be removed before installing the FPRx. For more information on this
installation option, see Installing FPRx and site support module in the Installing Flexi
Cabinet for Outdoor (FCOA) document.
Figure 72 AC interface support

ACinterfacesupport

Issue: 05 DN09142359 77
   

Principles for installing Flexi Power Rectifier (FPRx) in Installing Flexi Multiradio Base Station and Flexi
Flexi Multiradio BTS configurations Multiradio 10 Base Station Optional Items

Floor installations
• In outdoor installations, Flexi Mounting Covers for Back and Front 3U (FMCA) must
be used.
• The recommended location is the bottom of the stack. This allows for easier future
expansion.

Note that when using a front cover the air deflector plate has to be fixed to the front
cover first. It is included in the FPRB delivery.
Wall and pole installations
• In outdoor installations, Flexi Mounting Covers for Back and Front 3U (FMCA) must
be used.
• The recommended location is either on the same plinth as the System Module or on
an adjacent plinth.

78 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

10  Installing Flexi Power AC/DC sub-module
230V (FPAD/FPAE)

10.1  Installing Flexi Power AC/DC sub-module (FPAD)
on a wall
Purpose
These instructions show how to install Flexi Power AC/DC sub-module (FPAD) 472805A
on a wall. No installation kit is required. Install the FPAD in proximity of a Flexi 2TX
Remote Radio Head so that its 65 cm (25.6 in.) long DC cable can be routed through the
RRH DC cable clamp and connected to the RRH screw terminal. Leave a minimum
space of 1 cm (0.4 in.) between the FPAD and RRH. This includes the cable tie plate of
the RRH.
The installation distance is limited by the FPAD DC cable's physical path as well as the
location of the RRH DC terminal location.

Before you start

f WARNING! Danger of lethal voltages.
Switch off the AC power breaker before connecting the AC cable.

t Tip:  Always install Flexi Power AC/DC sub-module (FPAD) in a vertical position. The
recommended installation location is on either side of the RRH. This allows optimal
cooling for the RRH.
Do not route the cables so that the cooling fins are blocked.

For more information on the FPAD sub-module, see Flexi Power AC/DC sub-module
(FPAD) description in Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station
Optional Items Description.

Issue: 05 DN09142359 79
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

Procedure

1 On the backside of the FPAD, undo the four screws holding the AC connector
cover in place and open it.

Figure 73 Opening the AC connector cover

2 Loosen the screws on the AC cable clamp and thread your AC power cable
through the IP boot.
Loosen the two screws on the AC cable clamp to remove the boot.

80 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Figure 74 Loosening the AC cable clamp screws

Figure 75 AC cable routing

Issue: 05 DN09142359 81
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

3 Connect the AC power cable to the AC terminal.

Figure 76 Wires connected

Tighten the M3 screws to 0.5 - 0.6 Nm (0.4 - 0.44 ft-lb.).

4 Close the AC connector cover.
Tighten the M4 screws to 2.0 - 2.2 Nm (1.48 - 1.62 ft-lb.).
Make sure that the IP seal of the AC connector cover is installed properly.

82 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Figure 77 Closing the AC connector cover

5 Tighten the AC cable clamp screws.

Figure 78 AC cable clamp screws fixed

Issue: 05 DN09142359 83
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

6 Using the FPAD as a template, mark the screw hole locations on the wall.

Figure 79 Marking the fixing points

7 Drill the holes.

8 Install the FPAD and fix it with three screws (included in the accessory bag).

9 Connect the RRH DC cabling.

10 Turn the switch on the FPAD to the "On" position.

10.2  Installing Flexi Power AC/DC sub-module (FPAD) to
a pole-mounted RRH
These instructions show how to install Flexi Power AC/DC sub-module (FPAD) 472805A
on a pole on the backside of a Flexi 2TX Remote Radio Head.

84 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Purpose
You need a Flexi Pole Mounting Kit (FPKA) for this installation.

Before you start

f WARNING! Danger of lethal voltages.
Switch off the AC power breaker before connecting the AC cable.

w NOTICE: NOTICE: The weight of the RRH can damage the lower fixing bracket. Do not
rest the RRH on the lower fixing bracket. Do not put force on the lower fixing bracket
when lifting the RRH.

t Tip:  Always install Flexi Power AC/DC sub-module (FPAD) in a vertical position.
Note also that the routing of the cables should not block the cooling fins.

For more information on the FPAD sub-module see Flexi Power AC/DC sub-module
(FPAD) description in Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station
Optional Items Description.

Issue: 05 DN09142359 85
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

Procedure

1 Install Flexi Pole Mounting Kit (FPKA).

2 On the backside of the FPAD, undo the four screws holding the lid in place and
open the AC connector cover.

Figure 80 Opening the AC connector cover

3 Loosen the screws on the AC cable clamp and thread your AC power cable
through the IP boot.
Loosen the two screws on the AC cable clamp to remove the boot.

86 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Figure 81 Loosening the AC cable clamp screws

Figure 82 AC cable routing

Issue: 05 DN09142359 87
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

4 Connect the AC power cable to the AC terminal.

Figure 83 Wires connected

Tighten the M3 screws to 0.5 - 0.6 Nm (0.4 - 0.44 ft-lb.) .

5 Close the AC connector cover.
Tighten the M4 screws to 2.0 - 2.2 Nm (1.48 - 1.62 ft-lb.).
Make sure that the IP seal of the AC connector cover is installed properly.

88 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Figure 84 Closing the AC connector cover

6 Tighten the AC cable clamp screws.

Figure 85 AC cable clamp screws fixed

7 Fit the FPAD on the RRH mounting brackets and fix with three screws
(included in the accessory bag).
Flip the RRH over so that it is resting carefully on the solar shield. Use the fixing
points shown in Figure 86: Fixing points.

Issue: 05 DN09142359 89
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

The FPAD can be installed on the left or right side of the RRH mounting kit brackets.
Each side has two sets mounting holes for the FPAD, depending on the RRH
mounting dimensions. Note that some RRH variants only have one fixing location on
the back (no left or right).

Figure 86 Fixing points

90 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Figure 87 FPAD installed using the right-hand side fixing points

Issue: 05 DN09142359 91
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

8 Install Flexi 2TX Remote Radio Head on the FPKA.

9 Connect the RRH DC cabling.

10 Turn the switch on the FPAD to the "On" position.

10.3  Installing Flexi Power AC/DC sub-module (FPAE)
on a wall
These instructions show how to install Flexi Power AC/DC sub-module (FPAE) 472953A
on a wall.

Purpose
No installation kit is required. Install the FPAE in proximity of a Flexi 4TX Remote Radio
Head so that its 1 m (39.4 in.) long DC cable can be routed through the RRH DC cable
clamp and connected to the RRH screw terminal. Leave a minimum space of 1 cm (0.4
in.) between the FPAE and RRH. This includes the cable tie plate of the RRH.
Consider the following when choosing an installation location for a wall-mounted FPAE:

• The installation distance is limited by the physical path of the FPAE DC cable as well
as the location of the RRH DC terminal location.
• The maximum installation distance from the RRH:
– Below: 350 mm from front face of RRH
– Side: 150 mm side of lower bracket

• If FPAE is wall-mounted to the right of the RRH, leave ground maintenance space.
• It is recommended to wall-mount FPAE on the side of the RRH, level with the
exposed lower bracket/cable tie plate.

Before you start

f WARNING! Danger of lethal voltages.
Switch off the AC power breaker before connecting the AC cable.

t Tip:  Always install Flexi Power AC/DC sub-module (FPAE) in a vertical position. The
recommended installation location is on either side of the RRH. This allows optimal
cooling for the RRH.
Do not route the cables so that the cooling fins are blocked.

For more information on the FPAE sub-module, see Flexi Power AC/DC sub-module
(FPAE) description in Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station
Optional Items Description.

92 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Procedure

1 Fix the two M5 grounding screws (included in the accessory bag).

2 On the backside of the FPAE, undo the four screws holding the AC connector
cover in place and open it.

Figure 88 Opening the AC connector cover

3 Loosen the screws on the AC cable clamp and thread your AC power cable
through the IP boot.
Loosen the two screws on the AC cable clamp to remove the boot.

Figure 89 Loosening the AC cable clamp screws

t Tip:  Use pliers to route the AC wires into the AC terminal.

Issue: 05 DN09142359 93
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

Figure 90 AC cable routing

94 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

4 Connect the AC power cable to the AC terminal.

Figure 91 Wires connected

N L

Tighten the M3 screws to 0.5 - 0.6 Nm (0.4 - 0.44 ft-lb.).

5 Close the AC connector cover.
Tighten the M4 screws to 2.0 - 2.2 Nm (1.48 - 1.62 ft-lb.).
Make sure that the IP seal of the AC connector cover is installed properly.

Figure 92 Closing the AC connector cover

Issue: 05 DN09142359 95
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

6 Tighten the AC cable clamp screws.

Figure 93 AC cable clamp screws fixed

7 Using the FPAE as a template, mark the screw hole locations on the wall.

Figure 94 Marking the fixing points

96 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

8 Drill the holes.

9 Install the FPAE and fix it with three M5 screws (included in the accessory
bag).

10 Connect the RRH DC cabling.

11 Make sure that the FPAE is powered on when AC power is supplied to the unit.
FPAE has a push-button switch that automatically comes on when AC power is
supplied to the unit.

10.4  Installing Flexi Power AC/DC sub-module (FPAE) to
a pole-mounted RRH
These instructions show how to install Flexi Power AC/DC sub-module (FPAE) 472953A
on a pole on the backside of a Flexi 4TX 40W Remote Radio Head.

Purpose
You need a Flexi Pole Mounting Kit (FPKA) for this installation.

Before you start

f WARNING! Danger of lethal voltages.
Switch off the AC power breaker before connecting the AC cable.

w NOTICE: The weight of the RRH can damage the lower fixing bracket. Do not rest the
RRH on the lower fixing bracket. Do not put force on the lower fixing bracket when
lifting the RRH.

t Tip:  Always install Flexi Power AC/DC sub-module (FPAE) in a vertical position. Make
sure that the routing of the cables does not block the cooling fins.

If you are installing three 4TX RRHs with FPAEs behind them, see Figure 95: FPAE
offset mounting for the offset mounting (top view).

Issue: 05 DN09142359 97
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

Figure 95 FPAE offset mounting

For more information on the FPAE sub-module, see Flexi Power AC/DC sub-module
(FPAE) description in Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station
Optional Items Description.

98 DN09142359 Issue: 05
   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Procedure

1 Install the two M5 grounding screws (included in the accessory bag).

2 Install Flexi Pole Mounting Kit (FPKA).

3 On the backside of the FPAE, undo the four screws holding the lid in place and
open the AC connector cover.

Figure 96 Opening the AC connector cover

4 Loosen the screws on the AC cable clamp and thread your AC power cable
through the IP boot.
Loosen the two screws on the AC cable clamp to remove the boot.

Figure 97 Loosening the AC cable clamp screws

Issue: 05 DN09142359 99
   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

t Tip:  Use pliers to route the AC wires into the AC terminal.

Figure 98 AC cable routing

100 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

5 Connect the AC power cable to the AC terminal.

Figure 99 Wires connected

N L

Tighten the M3 screws to 0.5 - 0.6 Nm (0.4 - 0.44 ft-lb.) .

6 Close the AC connector cover.
Tighten the M4 screws to 0.8 - 1.0 Nm (0.6 - 0.7 ft-lb.).
Make sure that the IP seal of the AC connector cover is installed properly.

Figure 100 Closing the AC connector cover

Issue: 05 DN09142359 101


   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

7 Tighten the AC cable clamp screws.

Figure 101 AC cable clamp screws fixed

8 Fit the FPAE on the RRH and fix with three M5 screws (included in the
accessory bag).
Flip the RRH over so that it is resting carefully on the solar shield. Use the fixing
points shown in Figure 102: Fixing points.

Figure 102 Fixing points

102 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

9 Install the RRH on the FPKA.

10 Connect the RRH DC cabling.

11 Make sure that the FPAE is powered on when AC power is supplied to the unit.
FPAE has a push-button switch that automatically comes on when AC power is
supplied to the unit.

10.5  Installing Flexi Power AC/DC sub-module
(FPAD/FPAE) on a pole
These instructions show how to install Flexi Power AC/DC sub-module (FPAD/FPAE)
472805A/472953A on a pole using any commercial fixing brackets (jubilee clips, bands,
or clamps).

Purpose

g Note:
CAUTION! Risk of personal injury.
Ensure that the selected fixing hardware can sustain the unit under required
circumstances. The selected mounting hardware should be rated for outdoor use and
be capable of securing the unit weight in the environmental conditions specified in
Installation Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station
Installation Site Requirements.

Install the FPAD/FPAE in proximity of a Flexi Remote Radio Head so that its DC cable
(FPAD: 65 cm (25.6 in.), FPAE: 1 m (39.4 in.)) can be routed through the RRH DC cable
clamp and connected to the RRH screw terminal. Leave a minimum space of 1 cm (0.4
in.) between the FPAx and RRH. This includes the cable tie plate of the RRH.
The installation distance is limited by the physical path of the FPAx DC cable as well as
the location of the RRH DC terminal location.
The figures in these steps show the FPAD.

Before you start

f WARNING! Danger of lethal voltages.
Switch off the AC power breaker before connecting the AC cable.

t Tip:  Always install Flexi Power AC/DC sub-module (FPAx) in a vertical position.
Do not route the cables so that the cooling fins are blocked.

For more information on the FPAx sub-modules, see Flexi Multiradio Base Station and
Flexi Multiradio 10 Base Station Optional Items Description.

Issue: 05 DN09142359 103


   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

Procedure

1 On the backside of the FPAx, undo the four screws holding the lid in place and
open the AC connector cover.

Figure 103 Opening the AC connector cover

2 Loosen the screws on the AC cable clamp and thread your AC power cable
through the IP boot.
Loosen the two screws on the AC cable clamp to remove the boot.

104 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Figure 104 Loosening the AC cable clamp screws

Figure 105 AC cable routing

Issue: 05 DN09142359 105


   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

3 Connect the AC power cable to the AC terminal.

Figure 106 Wires connected

Tighten the M3 screws to 0.5 - 0.6 Nm (0.4 - 0.44 ft-lb.) .

4 Close the AC connector cover.
Tighten the M4 screws to 2.0 - 2.2 Nm (1.48 - 1.62 ft-lb.).
Make sure that the IP seal of the AC connector cover is installed properly.

106 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power AC/DC sub-module 230V
Multiradio 10 Base Station Optional Items (FPAD/FPAE)

Figure 107 Closing the AC connector cover

5 Tighten the AC cable clamp screws.

Figure 108 AC cable clamp screws fixed

Issue: 05 DN09142359 107


   

Installing Flexi Power AC/DC sub-module 230V Installing Flexi Multiradio Base Station and Flexi
(FPAD/FPAE) Multiradio 10 Base Station Optional Items

6 Thread your commercial fixing brackets (made of metal) through the slot
openings at the top and bottom of the FPAx.

Figure 109 Fixing brackets

6 7

7 Mount the FPAx on the pole and tighten the fixing brackets.

8 Connect the RRH DC cabling.

9 Make sure that the FPAx is powered on:

• For FPAD, turn the switch on the FPAx to the "On" position.
• FPAE has a push-button switch that automatically comes on when AC power is
supplied to the unit.

108 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

11  Installing Flexi Power Distribution and Fuses
Outdoor (FPFC) (Efore)
These instructions show how to install and connect the cabling of Flexi Power
Distribution and Fuses Outdoor (FPFC) (Efore).

Purpose
The following installation options are available for Flexi Power Distribution and Fuses
Outdoor (FPFC) 472508A:

• Inside a 2U casing (EMTA)
• Inside a 3U casing (EMHA)
• Inside a 19-inch rack or cabinet
• Chained with another FPFC or a System Module power distribution unit

EMTA/EMHA casings are not delivered with FPFC and must be ordered separately.
Note also that if FPFC is installed in a tower, an OVP box is needed to protect the DC
power supply.
For information on the FPFC unit and cable properties, see Flexi Power Distribution and
Fuses Outdoor (FPFC) Description. FPFC delivery contents are listed in section
Contents of the Flexi Power Distribution and Fuses Outdoor (FPFC) delivery.

Figure 110 Flexi Power Distribution and Fuses Outdoor (FPFC)
FPFC EACconnector On/OffBar

Inputconnector Outputconnector
IP boot Inputconnector IP boot

See Figure 111: FPFC installation example for an example FPFC installation.

Issue: 05 DN09142359 109


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

Figure 111 FPFC installation example

FODA
FPFC RFM

Outdoor FODA
FPFC

SystemModule

SystemModule

11.1  Installing Flexi Power Distribution and Fuses
Outdoor (FPFC) (Efore) inside a casing
These instructions show how to install a Flexi Power Distribution and Fuses Outdoor
(FPFC) (Efore) inside a casing.

Purpose

Table 4 FPFC cable sizes
Cable    
Wire cross-section Outer diameter

Output cable 2.5 mm2 (14 AWG) to 35 mm2 6.5 - 28 mm


(1 AWG)

110 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

Table 4 FPFC cable sizes (Cont.)
Cable    
Wire cross-section Outer diameter

Input cable 2.5 mm2 (14 AWG) to 50 mm2 8 - 28 mm


(0 AWG)

Grounding cable 50 mm2 (0 AWG)

• If the cable length is less than 4 m, a single wire cable can be used.
• If the cable length is more than 4 m and less than 10 m, a shielded cable must be used.

Before you start
Make sure that the FPFC is powered off before connecting any cables.

Procedure

1 Insert the FPFC halfway into a 2U or 3U casing.
If the FPFC is installed in a 2U casing and two channels of 50 mm2 (0 AWG) input
cable are connected, the maximum cable sizes supported by the output ports are 6 x
16 mm outer diameter single-wire cable or 5 x 2 pcs of 13.5 mm outer diameter
cable.

2 Connect the grounding cable between the FPFC front panel and the grounding
point.
Connect the cable between the FPFC front panel fixing point and the grounding
point, for example the plinth. See Figure 112: FPFC (Efore) grounding points for the
location of the FPFC front panel fixing points. There is one point for M8 size screw
and two for M5 sized screws.

Figure 112 FPFC (Efore) grounding points

M5Groundingpoints

Issue: 05 DN09142359 111


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

3 Connect the EAC cable to FPFC.
See Figure 113: EAC cable routing for an example of the EAC cable routing. The
cable connector sealing can be detached to connect the EAC connector.

Figure 113 EAC cable routing

EACcable

f CAUTION! Risk of damage to equipment
Connector seals or boots must be installed at all times, whether the site is active or not.

4 Prepare the input cabling.
Make sure all the cables are prepared. Note that if the cable diameter is >20 mm
(0.79 in.), it is too hard to route the cable with cable entries and front cover in place.
If the cable diameter is >20 mm (0.79 in.), follow these steps to prepare the cable:
a) Strip off the outer jacket of the cable as shown in Figure 114: Cable outer jacket
stripping (input from right-hand side). Note that these measurements are the
maximum values for a case where the cabling is routed by the right-hand side of
the FPFC.
Figure 114 Cable outer jacket stripping (input from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

112 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

If the input cabling is routed by the left-hand side of the FPFC, the
measurements are the following:
Figure 115 Cable outer jacket stripping (input from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

b) Cold shrink tubing (CS73327.26) must be used to provide UV and ingress
protection. See Figure 116: Three-fingered cold shrink tube installed for example
usage.
Figure 116 Three-fingered cold shrink tube installed

Cable

Coldshrinkingtubing

5 Insert the input cables to the IP boots.
Observe the following when routing cables through the IP boots:
• Cut the center of the boot according to the cable diameter so that the
reinforcement ring is intact, and make sure that the cable cross ports are not
damaged.
• If the cable diameter is > 15mm (0.6 in.), cut the boot as shown in Figure 117:
Cable diameters for input IP boot.

Issue: 05 DN09142359 113


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

Figure 117 Cable diameters for input IP boot
Cuttinginstructionaccording
toinputcableoutsidediameter:
Diameter13-15mm
Cablediameter8-28mm (0.51-0.59in)
(0.31-1.1in)
Diameter13-17mm
(0.51-0.67in)

Cablediameter8-16mm Diameter8-13mm
(0.31-0.63in) (0.31-0.51in)

Diameter17-28mm
(0.67-1.1in)

• Route the cables carefully through the boot. Make sure the cable size is correct
for the boot cable diameter.
• The copper shielding wire should also be wrapped up with single cold shrink
tubing (type CS930345) as shown.
Make sure that the tube ends are properly sealed.

6 Strip the necessary conductor wires of the input cables.
See figures below for details. The recommended length for the exposed wire is 17
mm (0.67 in.).

Figure 118 Cable diameter >20 mm (0.79 in.) (input from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

114 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

Figure 119 Cable diameter >20 mm (0.79 in.) (input from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

Figure 120 Cable diameter <20 mm (0.79 in.)

40mm (1.6in.)

17mm (0.7in.)

60mm (2.4in.)
ShieldingLength

g Note:  Make sure that the cable insulation is not damaged. The diffuse copper wire
should be bushed so that it is easy to connect.

7 Connect the 48V DC input cables.
Insert the cables to the input and output connectors as required. Each input
connector can support two power supplies. Exercise care when connecting the
cables as the FPFC core is not fixed to the casing at this point.
a) Insert the cables to the input connector. The cable size support for input cable is
2.5 - 50 mm2 (14 AWG - 1 AWG), and GND cable size can be 2.5 - 50 mm2 (14
AWG - 1 AWG).

Issue: 05 DN09142359 115


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

Figure 121 Input cable connectors

max.50mm2

b) Fix the connection screws and attach the IP boot to the connector. Use a Torx 25
screwdriver.
Figure 122 Fixing the input cable connection

g Note:  Make sure the IP boots are undamaged. Make sure that the cables are properly
installed to the connectors.
The torque for the connection fixing screw is 4 Nm (3 ft-lb.).

116 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

Figure 123 Typical input cabling from right-hand side for single FPFC

It is also possible to route the cables from the left-hand side.
If required, input power for the FPFC can be fed from both sides with two DC cables.
These cables must have exactly the same dimension, type and length so that power
is distributed from them equally. This can be used, for example, in following cases:
• The original plan was to use only half of the outputs and input cable
dimensioning was done according to this, and if all outputs are used, a second
same size and length cable can be installed instead of replacing the existing
cable with a thicker one
• If distance, power demand and loss requirements show that input cable must be
thicker than the maximum supported size for the input connector, cabling from
both sides can be a solution
• In some cases two smaller cables can be more cost effective when compared
with one thicker cable because of market situation.
See Figure 124: FPFC input cabling from both sides for example cabling.

Figure 124 FPFC input cabling from both sides
FPFC

8 Prepare the output cabling.
Make sure all cables are prepared. Note that if the cable diameter is >20 mm (0.79
in.), it is too hard to route the cable with cable entries and front cover in place.
If the cable diameter is >20 mm (0.79 in.), follow these steps to prepare the cable:

Issue: 05 DN09142359 117


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

a) Strip off the outer jacket of the cable as shown in Figure 125: Cable outer jacket
stripping (output from right-hand side). Note that these measurements are the
maximum values for a case where the cabling is routed by the right-hand side of
the FPFC.
Figure 125 Cable outer jacket stripping (output from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

If the cabling is routed by the left-hand side of the FPFC, the measurements are
the following:
Figure 126 Cable outer jacket stripping (output from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

b) Cold shrink tubing (CS73327.26) must be used to provide UV and ingress
protection. See Figure 127: Three-fingered cold shrink tube installed for example
usage.
Figure 127 Three-fingered cold shrink tube installed

Cable

Coldshrinkingtubing

9 Insert the output cables to the IP boots.
Observe the following when routing cables through the IP boots:

118 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

• Cut the center of the boot according to the cable diameter so that the
reinforcement ring is intact and make sure that the cable cross ports are not
damaged.
• If the cable diameter is > 15 mm (0.6 in.), cut the boot as shown in Figure 128: IP
boot cutting.
Figure 128 IP boot cutting
Cuttinginstructionaccording
tooutputcableoutsidediameter:
Diameter14-22mm
(0.55-0.87in)

Diameter10-14mm
(0.39-0.55in)

Diameter6.5-10mm
(0.26-0.39in)

Cablediameter6.5-20mm
(0.26-0.79in)

Cablediameter6.5-11mm
(0.26-0.43in)

Cablediameter6.5-20mm
(0.26-0.79in)
• Route the cables carefully through the boot. Make sure the cable size is correct
for the boot cable diameter.
• The copper shielding wire should also be wrapped up with single cold shrink
tubing (type CS930345) as shown.
Make sure that the tube ends are properly sealed.

10 Strip the necessary conductor wires of the output cables.
See figures below for details. The recommended length for the exposed wire is 17
mm (0.67 in.).

Issue: 05 DN09142359 119


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

Figure 129 Cable diameter >20 mm (0.79 in.)(output from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

Figure 130 Cable diameter >20 mm (0.79 in.) (output from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

Figure 131 Cable diameter <20 mm (0.79 in.)

40mm (1.6in.)

17mm (0.7in.)

60mm (2.4in.)
ShieldingLength

g Note:  Make sure that the cable insulation is not damaged. The diffuse copper wire
should be bushed so that it is easy to connect.

11 Connect the 48V DC output cables.
Insert the cables to the output connectors as required.
a) Insert the cables to the output connectors. Current loads of 45A require an
appropriate rated cable that has min. 10 mm2/6 AWG conductors. This also
applies to the four adjustable ports when operated in the 45A fuse setting mode.
Always follow country-specific local regulations.

120 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

Figure 132 Output cable connectors and GND, max values

max.16mm 2 max.35mm2
(6 AWG) (2 AWG)
b) Fix the connection screws using a Torx 20 screwdriver and fix the IP boots to the
connectors.
Figure 133 Fixing the output cable connection

g Note:  Make sure the IP boots are undamaged. Make sure that the cables are properly
installed to the connectors.
The torque for the connection fixing screw is 4 Nm (3 ft-lb.).

Issue: 05 DN09142359 121


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

12 Push the FPFC into the casing and fix with screws.

13 Attach the cable entries on both sides of the module.
Use four M5 x 10 screws for attaching the cable entries.

Figure 134 Cable routing in 2U casing with left-hand side input cabling

14 Route the cables through the cable entries.
For pole installations, use Flexi Side Covers (FMHA/FMTA) if you are routing cables
on both sides of the FPFC.

15 Check the position of the On/Off bar(s).
The bar(s) should be in ‘On’ position.

Figure 135 On/Off bar ‘On’ position

ON

122 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

16 Check the position of output current knob(s).
The knob(s) can be adjusted with a flathead screwdriver. Note that only right-hand
side channels’ 3-6 output current can be adjusted. The available current values are
4A, 20A, 30A, and 45A.

Table 5 FPFC fuse settings
Fuse setting Typical use
4A MWR radio link
20A 2TX 40W or 2TX 60W RRH
30A 3TX 60W RF Module
4TX 30W RRH
4TX 40W RRH

45A 3TX 80W RF Module
6TX 40W RF Module
6TX 60W RF Module

Figure 136 Adjusting the output current knob

17 Fix the cable clamps on cable entries, if necessary.

18 Fix the cables with cable clamps or cable ties.

19 Install the front cover.

11.2  Installing Flexi Power Distribution and Fuses
Outdoor (FPFC) (Efore) in a chained configuration
These instructions show how to install a Flexi Power Distribution and Fuses Outdoor
(FPFC) (Efore) in a chained configuration.

Purpose

Issue: 05 DN09142359 123


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (Efore) Multiradio 10 Base Station Optional Items

Chaining two FPFCs is necessary for large configurations when more than six outlets for
Flexi Modules or any standard -48 V DC devices are needed. Chaining also allows using
the FPFC as a powerful OVP to protect the DC input of the System Module.

Procedure

1 Connect the EAC cable.

f CAUTION! Risk of damage to equipment
Connector seals or boots must be installed at all times, whether the site is active or not.

2 Route and prepare the required cabling based on site requirements.
See Installing Flexi Power Distribution and Fuses Outdoor (FPFC) (Efore) inside a
casing for information on preparing the cables.

3 Connect the input cable.
Connect the main FPFC input cable as in Installing Flexi Power Distribution and
Fuses Outdoor (FPFC) (Efore) inside a casing. Connect the slave FPFC’s or System
Module input connector with the main FPFC as shown in Figure 137: Two FPFCs
chained. Make sure the polarity matches the chained unit.

g Note:  The conductor cross-section of the incoming cable and chaining cable have to be
identical. Do not use a thinner cable for chaining.

Figure 137 Two FPFCs chained

SlaveFPFC/SystemModule/DCfeedercable
Chainingcables

MasterFPFC

4 Check the position of the On/Off bar(s).
It should be in “On” position.

124 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (Efore)

5 Check the position of output current knob(s).
The knob(s) can be adjusted with a flathead screwdriver. Note that only channels’ 3-
6 output current can be adjusted.

6 Fix the cable clamps on cable entries, if necessary.

7 Fix the cables with cable clamps or cable ties.

8 Install the front cover.

Issue: 05 DN09142359 125


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

12  Installing Flexi Power Distribution and Fuses
Outdoor (FPFC) (AcBel)
These instructions show how to install and connect the cabling of Flexi Power
Distribution and Fuses Outdoor (FPFC) (AcBel).

Purpose
The following installation options are available for Flexi Power Distribution and Fuses
Outdoor (FPFC) 472508A:

• Inside a 2U casing (EMTA)
• Inside a 3U casing (EMHA)
• Inside a 19-inch rack or cabinet
• Chained with another FPFC or a System Module power distribution unit

EMTA/EMHA casings are not delivered with FPFC and must be ordered separately.
Note also that if FPFC is installed in a tower, an OVP box is needed to protect the DC
power supply.
For information on the FPFC unit and cable properties, see Flexi Power Distribution and
Fuses Outdoor (FPFC) Description. FPFC delivery contents are listed in section
Contents of the Flexi Power Distribution and Fuses Outdoor (FPFC) delivery.

Figure 138 Flexi Power Distribution and Fuses Outdoor (FPFC)

FPFC EACconnector On/OffBar

Inputconnector Outputconnector
IP boot Inputconnector IP boot

See Figure 139: FPFC installation example for an example FPFC installation.

126 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

Figure 139 FPFC installation example

FODA
FPFC RFM

Outdoor FODA
FPFC

SystemModule

SystemModule

12.1  Installing Flexi Power Distribution and Fuses
Outdoor (FPFC) (AcBel) inside a casing
These instructions show how to install a Flexi Power Distribution and Fuses Outdoor
(FPFC) (AcBel) inside a casing.

Purpose

Table 6 FPFC cable sizes
Cable    
Wire cross-section Outer diameter

Output cable 2.5 mm2 (14 AWG) to 35 mm2 6.5 - 28 mm


(1 AWG)

Issue: 05 DN09142359 127


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

Table 6 FPFC cable sizes (Cont.)
Cable    
Wire cross-section Outer diameter

Input cable 2.5 mm2 (14 AWG) to 50 mm2 8 - 28 mm


(0 AWG)

Grounding cable 50 mm2 (0 AWG)

• If the cable length is less than 4 m, a single wire cable can be used.
• If the cable length is more than 4 m and less than 10 m, a shielded cable must be used.

Before you start
Make sure that the FPFC is powered off before connecting any cables.

Procedure

1 Insert the FPFC halfway into a 2U or 3U casing.
If the FPFC is installed in a 2U casing and two channels of 50 mm2 (0 AWG) input
cable are connected, the maximum cable sizes supported by the output ports are 6 x
16 mm outer diameter single-wire cable or 5 x 2 pcs of 13.5 mm outer diameter
cable.

2 Connect the grounding cable between the FPFC front panel and the grounding
point.
Connect the cable between the FPFC front panel fixing point and the grounding
point, for example the plinth. See Figure 140: FPFC AcBel grounding points for the
location of the FPFC front panel fixing points. There is one point for M8 size screw
and two for M5 sized screws.

Figure 140 FPFC AcBel grounding points

M5Groundingpoints

128 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

3 Connect the EAC cable to FPFC.
See Figure 141: EAC cable routing for an example of the EAC cable routing. The
cable connector sealing can be detached to connect the EAC connector.

Figure 141 EAC cable routing

EACcable

f CAUTION! Risk of damage to equipment
Connector seals or boots must be installed at all times, whether the site is active or not.

4 Prepare the input cabling.
Make sure all the cables are prepared. Note that if the cable diameter is >20 mm
(0.79 in.), it is too hard to route the cable with cable entries and front cover in place.
If the cable diameter is >20 mm (0.79 in.), follow these steps to prepare the cable:
a) Strip off the outer jacket of the cable as shown in Figure 142: Cable outer jacket
stripping (input from right-hand side). Note that these measurements are the
maximum values for a case where the cabling is routed by the right-hand side of
the FPFC.
Figure 142 Cable outer jacket stripping (input from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

Issue: 05 DN09142359 129


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

If the input cabling is routed by the left-hand side of the FPFC, the
measurements are the following:
Figure 143 Cable outer jacket stripping (input from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

b) Cold shrink tubing (CS73327.26) must be used to provide UV and ingress
protection. See Figure 144: Three-fingered cold shrink tube installed for example
usage.
Figure 144 Three-fingered cold shrink tube installed

Cable

Coldshrinkingtubing

5 Insert the input cables to the IP boots.
Observe the following when routing cables through the IP boots:
• Cut the center of the boot according to the cable diameter so that the
reinforcement ring is intact, and make sure that the cable cross ports are not
damaged.
• If the cable diameter is > 15mm (0.6 in.), cut the boot as shown in Figure 145:
Cable diameters for input IP boot.

130 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

Figure 145 Cable diameters for input IP boot
16-28mm
(0.63-1.1in)
13-16mm
(0.51-0.63in)

8-13mm
(0.31-0.51in)

Cablediameter8-28mm
(0.31-1.1in)

Cablediameter8-16mm
(0.31-0.63in)

Cablediameter8-16mm
(0.31-0.63in)

13-16mm 8-13mm
(0.51-0.63in) (0.31-0.51in)

• Route the cables carefully through the boot. Make sure the cable size is correct
for the boot cable diameter.
• The copper shielding wire should also be wrapped up with single cold shrink
tubing (type CS930345) as shown.
Make sure that the tube ends are properly sealed.

6 Strip the necessary conductor wires of the input cables.
See figures below for details. The recommended length for the exposed wire is 17
mm (0.67 in.).

Figure 146 Cable diameter >20 mm (0.79 in.) (input from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

Issue: 05 DN09142359 131


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

Figure 147 Cable diameter >20 mm (0.79 in.) (input from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

Figure 148 Cable diameter <20 mm (0.79 in.)

40mm (1.6in.)

17mm (0.7in.)

60mm (2.4in.)
ShieldingLength

g Note:  Make sure that the cable insulation is not damaged. The diffuse copper wire
should be bushed so that it is easy to connect.

7 Connect the 48V DC input cables.
Insert the cables to the input and output connectors as required. Each input
connector can support two power supplies. Exercise care when connecting the
cables as the FPFC core is not fixed to the casing at this point.
a) Insert the cables to the input connector. The cable size support for input cable is
2.5 - 50 mm2 (14 AWG - 1 AWG), and GND cable size can be 2.5 - 50 mm2 (14
AWG - 1 AWG).

132 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

Figure 149 Input cable connectors

max.50mm2

b) Fix the connection screws using a Torx 25 screwdriver. Fix the IP boot to the
connector securing it with plastic clips around the base of the boot.
Figure 150 Fixing the input cable connection

2x

g Note:  Make sure the IP boots are undamaged. Make sure that the cables are properly
installed to the connectors.
The torque for the connection fixing screw is 4 Nm (3 ft-lb.).

Issue: 05 DN09142359 133


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

Figure 151 Typical input cabling from right-hand side for single FPFC

It is also possible to route the cables from the left-hand side.
If required, input power for the FPFC can be fed from both sides with two DC cables.
These cables must have exactly the same dimension, type and length so that power
is distributed from them equally. This can be used, for example, in following cases:
• The original plan was to use only half of the outputs and input cable
dimensioning was done according to this, and if all outputs are used, a second
same size and length cable can be installed instead of replacing the existing
cable with a thicker one
• If distance, power demand and loss requirements show that input cable must be
thicker than the maximum supported size for the input connector, cabling from
both sides can be a solution
• In some cases two smaller cables can be more cost effective when compared
with one thicker cable because of market situation.
See Figure 152: FPFC input cabling from both sides for example cabling.

Figure 152 FPFC input cabling from both sides
FPFC

8 Prepare the output cabling.
Make sure all cables are prepared. Note that if the cable diameter is >20 mm (0.79
in.), it is too hard to route the cable with cable entries and front cover in place.
If the cable diameter is >20 mm (0.79 in.), follow these steps to prepare the cable:

134 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

a) Strip off the outer jacket of the cable as shown in Figure 153: Cable outer jacket
stripping (output from right-hand side). Note that these measurements are the
maximum values for a case where the cabling is routed by the right-hand side of
the FPFC.
Figure 153 Cable outer jacket stripping (output from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

If the cabling is routed by the left-hand side of the FPFC, the measurements are
the following:
Figure 154 Cable outer jacket stripping (output from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

b) Cold shrink tubing (CS73327.26) must be used to provide UV and ingress
protection. See Figure 155: Three-fingered cold shrink tube installed for example
usage.
Figure 155 Three-fingered cold shrink tube installed

Cable

Coldshrinkingtubing

9 Insert the output cables to the IP boots.
Observe the following when routing cables through the IP boots:

Issue: 05 DN09142359 135


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

• Cut the center of the boot according to the cable diameter so that the
reinforcement ring is intact and make sure that the cable cross ports are not
damaged.
• If the cable diameter is > 15 mm (0.6 in.), cut the boot as shown in Figure 156: IP
boot cutting.
Figure 156 IP boot cutting

22-28mm(0.88-1.1in)
22-28mm(0.88-1.1in)
14-22mm(0.56-0.88in)
14-22mm(0.56-0.88in)
10-22mm(0.40-0.88in) 10-22mm(0.40-0.88in)
6.5-10mm(0.26-0.40in) 6.5-10mm(0.26-0.40in)

6.5-11mm(0.26-0.43in)

Cablediameter6.5-20mm
(0.26-0.79in)
• Route the cables carefully through the boot. Make sure the cable size is correct
for the boot cable diameter.
• The copper shielding wire should also be wrapped up with single cold shrink
tubing (type CS930345) as shown.
Make sure that the tube ends are properly sealed.

10 Strip the necessary conductor wires of the output cables.
See figures below for details. The recommended length for the exposed wire is 17
mm (0.67 in.).

Figure 157 Cable diameter >20 mm (0.79 in.)(output from right-hand side)

400mm(15.7in.)

17mm(0.7in.)

ShieldingLength420mm(16.5in.)

136 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

Figure 158 Cable diameter >20 mm (0.79 in.) (output from left-hand side)

300mm(11.8in.)

17mm(0.7in.)

ShieldingLength320mm(12.6in.)

Figure 159 Cable diameter <20 mm (0.79 in.)

40mm (1.6in.)

17mm (0.7in.)

60mm (2.4in.)
ShieldingLength

g Note:  Make sure that the cable insulation is not damaged. The diffuse copper wire
should be bushed so that it is easy to connect.

11 Connect the 48V DC output cables.
Insert the cables to the output connectors as required.
a) Insert the cables to the output connectors. Current loads of 45A require an
appropriate rated cable that has min. 10 mm2/6 AWG conductors. This also
applies to the four adjustable ports when operated in the 45A fuse setting mode.
Always follow country-specific local regulations.

Issue: 05 DN09142359 137


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

Figure 160 Output cable connectors and GND, max values

max.16mm 2 max.35mm2
(6 AWG) (2 AWG)

b) Fix the connection screws using a Torx 20 screwdriver and fix the IP boots to the
connectors securing them with the plastic clips around the base of the IP boots.

138 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

Figure 161 Fixing the output cable connection

g Note:  Make sure the IP boots are undamaged. Make sure that the cables are properly
installed to the connectors.
The torque for the connection fixing screw is 4 Nm (3 ft-lb.).

12 Push the FPFC into the casing and fix with screws.

13 Attach the cable entries on both sides of the module.
Use four M5 x 10 screws for attaching the cable entries.

Issue: 05 DN09142359 139


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

Figure 162 Cable routing in 2U casing with left-hand side input cabling

14 Route the cables through the cable entries.
For pole installations, use Flexi Side Covers (FMHA/FMTA) if you are routing cables
on both sides of the FPFC.

15 Check the position of the On/Off bar(s).
The bar(s) should be in ‘On’ position.

Figure 163 On/Off bar ‘On’ position

ON

140 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

16 Check the position of output current knob(s).
The knob(s) can be adjusted with a flathead screwdriver. Note that only right-hand
side channels’ 3-6 output current can be adjusted. The available current values are
4A, 20A, 30A, and 45A.

Table 7 FPFC fuse settings
Fuse setting Typical use
4A MWR radio link
20A 2TX 40W or 2TX 60W RRH
30A 3TX 60W RF Module
4TX 30W RRH
4TX 40W RRH

45A 3TX 80W RF Module
6TX 40W RF Module
6TX 60W RF Module

Figure 164 Adjusting the output current knob

17 Fix the cable clamps on cable entries, if necessary.

18 Fix the cables with cable clamps or cable ties.

19 Install the front cover.

Issue: 05 DN09142359 141


   

Installing Flexi Power Distribution and Fuses Outdoor Installing Flexi Multiradio Base Station and Flexi
(FPFC) (AcBel) Multiradio 10 Base Station Optional Items

12.2  Installing Flexi Power Distribution and Fuses
Outdoor (FPFC) (AcBel) in a chained configuration
These instructions show how to create a chained configuration for Flexi Power
Distribution and Fuses Outdoor (FPFC) (AcBel).

Purpose
Chaining two FPFCs is necessary for large configurations when more than six outlets for
Flexi Modules or any standard -48 V DC devices are needed. Chaining also allows using
the FPFC as a powerful OVP to protect the DC input of the System Module.

Procedure

1 Connect the EAC cable.

f CAUTION! Risk of damage to equipment
Connector seals or boots must be installed at all times, whether the site is active or not.

2 Route and prepare the required cabling based on site requirements.
See Installing Flexi Power Distribution and Fuses Outdoor (FPFC) (AcBel) above for
information on preparing the cables.

3 Connect the input cable.
Connect the main FPFC input cable as in Figure 165: Two FPFCs chained. Connect
the slave FPFC’s or System Module input connector with the main FPFC. Make sure
the polarity matches the chained unit.

g Note:  The conductor cross-section of the incoming cable and chaining cable have to be
identical. Do not use a thinner cable for chaining.

142 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Power Distribution and Fuses Outdoor
Multiradio 10 Base Station Optional Items (FPFC) (AcBel)

Figure 165 Two FPFCs chained
SlaveFPFC/SystemModule/DCfeedercable
Chainingcables

MasterFPFC

4 Check the position of the On/Off bar(s).
It should be in “On” position.

5 Check the position of output current knob(s).
The knob(s) can be adjusted with a flathead screwdriver. Note that only channels’ 3-
6 output current can be adjusted.

6 Fix the cable clamps on cable entries, if necessary.

7 Fix the cables with cable clamps or cable ties.

8 Install the front cover.

Issue: 05 DN09142359 143


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

13  Installing Flexi System External OVP (FSES)

13.1  Installing Flexi System External OVP (FSES) onto a
3U casing
Purpose
These instructions describe how to install Flexi System External OVP (FSES) 472285A
onto a 3U module casing (082795A.204 or newer).
FSES interfaces are shown in the following figure.

Figure 166 FSES interfaces

Alarminterface DCoutput/input
DCoutput/input
Grounding

g Note:  Do not open the FSES. If opened, the warranty is void.

Procedure

1 Make sure the 3U cable entries have been installed.

2 Install the FSES onto the module casing as shown in the below figure and fix
with two screws.
The distance between the RF Module and the FSES is limited by the length of the
output power cable (180 cm, 5.9 ft.) and its physical path.

144 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Figure 167 Installing FSES on casing

Tighten the screws to 2.0 - 2.5 Nm (1.5 - 1.8 ft-lb.).
Alternatively, you can connect the cabling first and then install the FSES ready-
cabled.

3 Connect the pre-installed grounding cable (994815) to the plinth.
Tighten to 2.0 - 2.5 Nm (1.5 - 1.8 ft-lb.).

Issue: 05 DN09142359 145


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 168 Connecting FSES grounding cable to plinth

RadioModule

146 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

4 Remove the FSES IP boot.

Figure 169 Removing FSES IP boot

5 Strip the DC power cable and wrap tape around the exposed wires in order not
to break the IP boot.

a) Strip the DC cable about 10 cm (4 in) and wrap tape around GND mesh and
cable sheath neck.
Figure 170 Wrapping tape around shielded DC cable

b) Wrap an extra tape around the exposed wires in order not to break the IP boot

Issue: 05 DN09142359 147


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 171 Wrapping an extra tape around DC cable

c) Insert the taped end of the DC feeder cable into the IP boot.
Figure 172 Inserting DC power cable to IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Cut in one go so that you get a clean cut surface. See Figure 173:
Removing narrow end of IP boot for details. Note that you can insert only one DC
cable with a diameter of maximum 25 mm to the IP boot. Minimum cable
diameter is 6 mm.

w NOTICE: The IP boot edge must be smooth. No crack in the edge is allowed, as it
breaks boot IP protection.

148 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Figure 173 Removing narrow end of IP boot

Cablediameter 20.1 -25.0 mm


cutwithscissorsinonego

Cablediameter15.1 -20.0 mm
cutwithscissorsinonego

Cablediameter10.1 - 15.0 mm
cutwithscissorsinonego

Cablediameter 6.0 - 10.0 mm


(nocuttingneed)

d) Remove the extra tape from DC cable.

g Note:  Keep the tape around the GND mesh and cable sheath neck to protect IP boot
from sharp edges.

Issue: 05 DN09142359 149


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 174 Properly secured shielded DC cable (left) and non-shielded DC
cable (right)

For DC feeder cable details, see Feederless site and Distributed site solution
requirements in the Flexi Multiradio Base Station and Flexi Multiradio 10 Base
Station Installation Site Requirements document.

6 Connect the wires to the screw terminal. Tighten to 3.0 Nm (2.21 ft-lb.).

Figure 175 Connecting DC feeder cable wires

GND -
+

Pay attention to the markings (V48N (-), V48RTN (+) and GND) on the FSES lid to
ensure correct polarity.
If you have a shielded DC cable, connect the shielding to the terminal marked with
GND. Note that the FSES grounding cable has to be connected to the plinth.

7 Fix the IP boot in place and fix the screw. Tighten to max. 2.0 Nm (1.5 ft-lb.).
Bend the IP boot to the side to make it easier to fix the screw.

150 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Figure 176 Fixing IP boot screw

Issue: 05 DN09142359 151


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

g Note:  On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals are protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible. If you use optional Flexi Side Covers (FMHA/FMTA),
also protect any cabling coming out the side cover kit with conduit. The below figure is
an example and shows conduit connected to the FSES EAC interface.

Figure 177 Example of conduit usage

8 Fix the DC feeder cable to the cable entry with a cable tie.
To ensure the FSES DC feeder cable proper strain relief, also fix the DC feeder cable
firmly to the surrounding structure of the Flexi module, as close as possible to the
input connection.

152 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Figure 178 Fixing DC feeder cable to cable entry

9 Depending on your cable routing, fix the DC power cable and grounding cable
to the cable entry with a cable tie.
It is recommended that the DC power cable is routed down.

Figure 179 Fixing DC power cable with cable tie

10 If applicable, connect the alarm cable following the steps below.
Alarm output is Normally Open type.
An alarm cable is not included in the FSES delivery. Use an alarm cable that meets
the following requirements:
• Minimum wire size 0.5 mm2 (20 AWG)
• Maximum wire size 2.5 mm2 (14 AWG)
• Round cable outer jacket diameter must be 8.3 +/- 0.5 mm

Issue: 05 DN09142359 153


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

• For the maximum length, see the maximum distance between the System
Module and RF Module in Feederless site and Distributed site solution
requirements in the Flexi Multiradio Base Station and Flexi Multiradio 10 Base
Station Installation Site Requirements document
• Maximum current 1.0 mA

a) Remove the alarm port IP boot.
Figure 180 Removing alarm port IP boot

b) Remove the IP plug from the IP boot.
Figure 181 Removing IP plug

c) Insert the alarm cable to the IP boot.

154 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Figure 182 Inserting alarm cable to IP boot

d) Connect the wires to the N.O. and Common terminals.
Figure 183 Connecting alarm cable wires

e) Fix the IP boot in place.

Issue: 05 DN09142359 155


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 184 Fixing alarm cable IP boot

156 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

g Note:  On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals are protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible. If you use optional Flexi Side Covers (FMHA/FMTA),
also protect any cabling coming out the side cover kit with conduit.

Figure 185 Example of conduit usage

f) Connect the other end of the alarm cable either to the EAC port on the System
Module front panel or to Flexi System External Alarm (FSEB). For RF Module
and RRH external alarm interface connections, use pre-defined EAC cables. See
chapter EAC cables in Flexi Multiradio Base Station and Flexi Multiradio 10 Base
Station Optional Items Description for a list of available cables.

11 Connect the ready-installed DC cable as required by your configuration:

• System Module (ESMB/C, FSMC/D/E) front panel: RF1/2/3 DC output port.
• System Module (FSMF) with FPFD PDU: RF1/2/3/4 output port.
• DC sourcing equipment (FPMA, FPRB or a commercial DC power source)
• System Module (FSMF) front panel DC input port (optional FPFD PDU not
installed)
• RF Module front panel or RRH: DC input port.
Cut off and discard the DC connector of the pigtail cable when OVP is used with
FPFD, FPMA, FPRB, commercial DC power system or RF Modules and RRHs with
DC terminal interfaces.
Make sure that the IP boot is installed properly on the System Module or RF Module
front panel.

Issue: 05 DN09142359 157


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

12 If applicable, install another FSES on top of the first one.
Repeat steps 3 to 11. Fix with four screws.
The maximum number of FSES's in a stack is two.

Figure 186 Two FSES’s stacked

13.2  Installing Flexi System External OVP (FSES) on a
Flexi cabinet rooftop
Instructions for installing a Flexi System External OVP (FSES) 472285A on the roof of
Flexi Cabinet for Indoor (FCIA) or Flexi Cabinet for Outdoor (FCOA).

Purpose
Use the fixing points on the cabinet roof. See the figures below for suggested positions,
however, if the rooftop is populated with other auxiliary equipment, use any available slot
for installing the FSES. Always make sure that the FSES can be fixed firmly and cables
tied appropriately.

158 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Figure 187 Example of FCIA rooftop installation

FSES

Figure 188 Example of FCOA rooftop installation (with FSEB)

FSEB FSES

g Note:  Do not open the FSES. If opened, the warranty is void.

Issue: 05 DN09142359 159


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Procedure

1 Using any small tool, knock off the installation hooks on the bottom of the
FSES with a light sideways blow. Alternatively, twist the hooks off with pliers.

2 Fix the FSES on the FCIA/FCOA rooftop with two screws on one side.

3 Connect the cabling as instructed in Installing Flexi System External OVP
(FSES) onto a 3U casing.

g Note:  If the ready-installed DC cable does not reach the System Module installed in
one of the bottommost slots in the FCIA cabinet, swap the System Module and RF
Module around so that the System Module moves higher in the configuration.

13.3  Installing Flexi System External OVP (FSES) onto
Flexi Pole Installation Kit (FPIA)

Purpose
These instructions describe how to install Flexi System External OVP (FSES) 472285A
on a pole using Flexi Pole Installation Kit (FPIA) (version 471767.202 or newer).

g Note:  Do not open the FSES. If opened, the warranty is void.

160 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Procedure

1 Install Flexi Pole Installation Kit (FPIA) as instructed in Installing Flexi Pole


Installation Kit (FPIA).

2 Fix the FSES on the FPIA with four screws.

Figure 189 FSES installed on FPIA

Issue: 05 DN09142359 161


   

Installing Flexi System External OVP (FSES) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

3 If you are installing more than one FSES on the FPIA, install the additional
FSES's as shown in the figures below.

Figure 190 Two FSES’s on FPIA

162 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSES)
Multiradio 10 Base Station Optional Items

Figure 191 Four FSES’s on FPIA

4 Connect the cabling as instructed in Installing Flexi System External OVP
(FSES) onto a 3U casing.

Issue: 05 DN09142359 163


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

14  Installing Flexi System External OVP (FSEP)

14.1  Installing Flexi System External OVP (FSEP) onto a
3U casing
These steps show how to install a Flexi System External OVP (FSEP) 473246A onto a
3U casing (082795A.204 or newer).

Purpose
FSEP interfaces are shown in the following figure.

Figure 192 FSEP interfaces

2-poleDCinterface 3-poleDCinterface
Alarminterface

Grounding

g Note:  Do not open the FSEP. If opened, the warranty is void.

164 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

Procedure

1 Make sure the 3U cable entries have been installed.

2 Install the FSEP onto the module casing as shown in the below figure and fix
with two screws.

Figure 193 Installing FSEP on casing

Tighten the screws to 2.0 - 2.5 Nm (1.5 - 1.8 ft-lb.).
Alternatively, you can connect the cabling first and then install the FSEP ready-
cabled.

3 Connect the pre-installed grounding cable (994815) to the plinth.
Tighten to 2.0 - 2.5 Nm (1.5 - 1.8 ft-lb.).

Issue: 05 DN09142359 165


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 194 Connecting FSEP grounding cable to plinth

RadioModule

166 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

4 Remove the IP boot from the 3-pole DC output interface.

Figure 195 Removing 3-pole DC output IP boot

5 Strip the DC power cable and wrap tape around the exposed wires to avoid
breaking the IP boot.

a) Strip the DC cable about 10 cm (4 in) and wrap tape around GND mesh and
cable sheath neck.
Figure 196 Wrapping tape around shielded DC cable

b) Wrap extra tape around the exposed wires to avoid breaking the IP boot.

Issue: 05 DN09142359 167


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 197 Wrapping extra tape around DC cable

c) Insert the taped end of the DC feeder cable into the IP boot.
Figure 198 Inserting DC power cable to IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Use a single cut so that you get a clean cut surface. See Figure 173:
Removing narrow end of IP boot for details. The IP boot takes a single cable
sheath with a maximum size of 35 mm2 (2 AWG). For supported cable diameters,
see Figure 199: Removing narrow end of IP boot.

w NOTICE: The IP boot edge must be smooth. No crack in the edge is allowed, as it
breaks the IP protection.

168 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

Figure 199 Removing narrow end of IP boot

Cablediameter 20.1 -25.0 mm


cutwithscissorsinonego

Cablediameter15.1 -20.0 mm
cutwithscissorsinonego

Cablediameter10.1 - 15.0 mm
cutwithscissorsinonego

Cablediameter 6.0 - 10.0 mm


(nocuttingneed)

d) Remove the extra tape from the DC cable.

g Note:  Keep the tape around the GND mesh and cable sheath neck to protect the IP
boot from sharp edges.

Issue: 05 DN09142359 169


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 200 Properly secured shielded DC cable (left) and non-shielded DC
cable (right)

For DC feeder cable details, see Feederless site and Distributed site solution
requirements in the Flexi Multiradio Base Station and Flexi Multiradio 10 Base
Station Installation Site Requirements document.

6 Connect the wires to the screw terminal. Tighten to 3.0 Nm (2.21 ft-lb.).

Figure 201 Connecting DC feeder cable wires

GND -
+

Pay attention to the markings (V48N (-), V48RTN (+) and GND) on the FSEP lid to
ensure correct polarity.
If you have a shielded DC cable, connect the shielding to the terminal marked with
GND. Note that the FSEP grounding cable has to be connected to the plinth.

7 Fix the IP boot in place and fix the screw. Tighten to max. 2.0 Nm (1.5 ft-lb.).
Bend the IP boot to the side to make it easier to fix the screw.

170 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

Figure 202 Fixing IP boot screw

Issue: 05 DN09142359 171


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

g Note:  On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals be protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible. If you use optional Flexi Side Covers (FMHA/FMTA),
also protect any cabling coming out the side cover kit with conduit. The below figure is
an example and shows conduit connected to the FSEP DC interface.

Figure 203 Example of conduit usage

8 Depending on your cable routing, fix the DC power cable to the cable entry
with a cable tie.
To ensure the FSEP DC feeder cable proper strain relief, also fix the DC feeder cable
firmly to the surrounding structure of the Flexi module, as close as possible to the
input connection.

172 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

Figure 204 Fixing DC feeder cable to cable entry

Issue: 05 DN09142359 173


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

9 Connect the 2-pole DC input interface following the steps below:

Figure 205 Connecting 2-pole DC input interface

a) Remove the IP boot from the 2-pole DC input interface.
b) Strip the DC power cable about 7 cm (2.76 in) and wrap tape around the
exposed wires to avoid breaking the IP boot.
c) Remove the narrow end of the IP boot using scissors. Cut in one go so that you
get a clean cut surface.
d) Insert the taped end of the DC feeder cable into the IP boot and remove the tape
from the DC cable.
e) Connect the wires to the screw terminal and tighten to 3.0 Nm (2.21 ft lbs). Pay
attention to the polarity markings on the DC terminal.
f) Fix the IP boot in place and fix the screw. Tighten to max. 2.0 Nm (1.5 ft-lb.).

g Note:  On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals are protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible. If you use optional Flexi Side Covers (FMHA/FMTA),
also protect any cabling coming out the side cover kit with conduit.

174 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

10 Connect the other end of the DC input cable as required by your configuration:

• System Module (FSMF) with FPFD PDU: RF1/2/3/4 output port.
• DC sourcing equipment (FPMA, FPRB or a commercial DC power source)
• FPFD PDU DC input port (limited to 80A current loads)
• System Module (FSMF) front panel DC input port (optional FPFD PDU not
installed)
• RF Module front panel or RRH: DC input port.
Make sure that the IP boot is installed properly on the System Module or RF Module
front panel.

11 If applicable, connect the alarm cable following the steps below.
Alarm output is Normally Closed type.
An alarm cable is not included in the FSEP delivery. Use an alarm cable that meets
the following requirements:
• Minimum wire size 0.14 mm2 (26 AWG)
• Maximum wire size 1.5 mm2 (16 AWG)
• Round cable outer jacket diameter must be 5 mm +/- 0.5 mm
• For the maximum length, see the maximum distance between the System
Module and RF Module in Feederless site and Distributed site solution
requirements in the Flexi Multiradio Base Station Installation Site and Flexi
Multiradio 10 Base Station Requirements document
• Maximum current 1.0 mA

Figure 206 Connecting FSEP alarm cable

Issue: 05 DN09142359 175


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

a) Remove the alarm port IP boot.
b) Wrap tape around the exposed alarm cable wires to protect the IP boot.
c) Insert the alarm cable to the IP boot and remove the tape.
d) Pull out the pluggable terminal block.
e) Connect the wires to the screw terminals. Tighten to 0.25 Nm (0.18 ft lbs).

g Note:  Make sure that the polarity is correct in order for the external alarms to work.

f) Push the pluggable terminal block back in place.
g) Fix the IP boot in place.

g Note:  On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals are protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible. If you use optional Flexi Side Covers (FMHA/FMTA),
also protect any cabling coming out the side cover kit with conduit.

h) Connect the other end of the alarm cable either to the EAC port on the System
Module front panel or to Flexi System External Alarm (FSEB). For RF Module
and RRH external alarm interface connections, use pre-defined EAC cables. See
chapter EAC cables in Flexi Multiradio Base Station and Flexi Multiradio 10 Base
Station Optional Items Description for a list of available cables.

12 If applicable, install another FSEP on top of the first one.
Repeat steps 3 to 16. Fix with four screws.
The maximum number of FSEP's in a stack is two.

176 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

Figure 207 Two FSEP’s stacked

14.2  Installing Flexi System External OVP (FSEP) on a
Flexi cabinet rooftop
Instructions for installing a Flexi System External OVP (FSEP) 473246A on the roof of
Flexi Cabinet for Indoor (FCIA) or Flexi Cabinet for Outdoor (FCOA).

Purpose
Use the fixing points on the cabinet roof. See the figures below for suggested positions,
however, if the rooftop is populated with other auxiliary equipment, use any available slot
for installing the FSEP. Always make sure that the FSEP can be fixed firmly and cables
tied appropriately.

Issue: 05 DN09142359 177


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 208 Example of FCIA rooftop installation

FSEP

Figure 209 Example of FCOA rooftop installation (with FSEB)

FSEB FSEP

g Note:  Do not open the FSEP. If opened, the warranty is void.

178 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

Procedure

1 Using any small tool, knock off the installation hooks on the bottom of the
FSEP with a light sideways blow. Alternatively, twist the hooks off with pliers.

2 Fix the FSEP on the FCIA/FCOA rooftop with two screws on one side.

3 Connect the cabling as instructed in Installing Flexi System External OVP
(FSEP) onto a 3U casing.

14.3  Installing Flexi System External OVP (FSEP) onto
Flexi Pole Installation Kit (FPIA)
These steps show how to install a Flexi System External OVP (FSEP) 473246A on a
pole using Flexi Pole Installation Kit (FPIA) (version 471767.202 or newer).

Purpose

g Note:  Do not open the FSEP. If opened, the warranty is void.

g Note:  The figures show the installation principle only and no cabling.

Issue: 05 DN09142359 179


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Procedure

1 Install Flexi Pole Installation Kit (FPIA) as instructed in Installing Flexi Pole


Installation Kit (FPIA).

2 Fix the FSEP on the FPIA with four screws.

Figure 210 FSEP installed on FPIA

180 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External OVP (FSEP)
Multiradio 10 Base Station Optional Items

3 If you are installing more than one FSEP on the FPIA, install the additional
FSEP's as shown in the figures below.

Figure 211 Two FSEP’s on FPIA

Issue: 05 DN09142359 181


   

Installing Flexi System External OVP (FSEP) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 212 Four FSEP’s on FPIA

4 Connect the cabling as instructed in Installing Flexi System External OVP


(FSEP) onto a 3U casing.

182 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

15  Installing Flexi Fiber Optical Distribution unit
(FODA)

15.1  Installing Flexi Fiber Optical Distribution unit
(FODA) in a stack
These instructions show how to install and connect the cabling of Flexi Fiber Optical
Distribution unit (FODA) for a stacked configuration.

Purpose
The following installation options are available for Flexi Fiber Optical Distribution unit
(FODA) 472606A:

• inside 3U casing (EMHA) with FPFC
• on top of a casing
• inside a 19-inch rack or cabinet
• on a pole
• on a wall.

Figure 213 Flexi Fiber Optical Distribution unit (FODA)

Cablegland

OPT1-3
OPT4-5
OPT6 OPT7 OPT8-9
OPT10-12
Cablegland
optional

Installation examples:

Issue: 05 DN09142359 183


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 214 Outdoor installation example

FODA
FPFC RFM

Outdoor
FODA

SystemModule

SystemModule

184 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

Figure 215 Installation example with FODA

Towertop

GSM/LTE

GSM/LTE GSM/WCDMA

FODA
FPFC
GSM/

ANT 1

ANT 1
Tx/Rx

Tx/Rx
OPT 2 OPT 3

OPT 2 OPT 3
WCDMA

RxOut

RxOut
ANT 1

ANT 1
ANT 2

ANT 2
Rx

Rx
OPT 1

OPT 1
ANT 3

ANT 3
Tx/Rx

Tx/Rx
RxOut

RxOut
ANT 3

ANT 3
ANT 4

ANT 4
Rx

Rx
ANT 5

ANT 5
Tx/Rx

Tx/Rx
EAC

EAC
RxOut

RxOut
ANT 5

ANT 5
ANT 6

ANT 6
Rx

Rx
PWRIN

PWRIN
RFjumper
Fiber FPFC+FODA v2
DC Max.24xSMFIBER
Max.12xDC

Groundlevel

FODA

LTEFSME

Power
cabinet
GSMESMB WCDMA FSME GSMESMB
FPA OPT1 OPT2 OPT3 OPT4 LMP Sync-Out Sync-In EAC Q1 FPA OPT1 OPT2 OPT3 OPT4 LMP Sync-Out Sync-In EAC Q1

PWR PWR PWR PWR PWR PWR PWR PWR PWR PWR

Follow these instructions to install FODA unit in a stack or rack.

Procedure

1 Open the lid of the FODA unit.
Open the lid of the FODA unit by removing the 14 M5 screws (TORX T25). See the
figure below, step 1.

Issue: 05 DN09142359 185


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 216 Opening the lid of FODA

2 Remove the connector seals from the relevant optical cable connectors in the
FODA unit.
See Figure 216: Opening the lid of FODA, step 2. Store the seals for later use. You
can store these inside FODA.

3 Change the location of the cable gland from the side to the front of the FODA
unit.
See Figure 216: Opening the lid of FODA, step 3. Changing the location of the cable
gland is only required for stack and rack installations.

4 Route the input fiber cables via the cable gland.
Detach first the nut from the cable gland and route the cables through the nut one by
one. Then route the cables through the cable gland. See Figure 217: Routing cables
through the cable gland.

186 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

Figure 217 Routing cables through the cable gland

5 Attach the input fiber cables to the relevant connectors inside the FODA.
See Figure 218: Routing fibers inside FODA for example routing. The cables are
numbered, so make sure to attach the cables to appropriate connectors.

Figure 218 Routing fibers inside FODA

12

1 2
3
4 5
6
7
8 9
10 11
12

Issue: 05 DN09142359 187


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

6 Tighten the cable gland to 0.7 Nm (0.5 ft-lb).
Make sure the cable IP sleeve is installed so that it goes through the gland as in the
figure below.

Figure 219 Tightening the cable gland

Cable IP sleeve

7 Close the lid.
Fix the lid with 14 M5 screws. Tighten the plastic screws to 0.3 Nm (0.2 ft-lb).

8 Fix the mounting brackets on each side of the FODA front panel.
The mounting brackets are required if the FODA is installed in a rack or in a 3U
casing together with FPFC, for example. Use a TORX T20 screwdriver.

188 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

Figure 220 Fixing the mounting brackets

9 Fix the FODA unit to the rack using the mounting brackets on both sides of the
unit.
Fix FODA to a 3U casing on top of FPFC and secure the casing with two screws in
the topmost position in the stack.

a) Install the FPFC first in the casing using either the lower or upper fixing points of
FPFC with one cage nut.
b) Install the FODA on top of the FPFC and fix it with two screws, one cage nut on
both sides.
c) Fix the cable entries to the casing with one M5 x 10 screw on both sides of the
FPFC. Use the lower fixing points of the cable entry.

Issue: 05 DN09142359 189


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 221 Installing FODA in a 3U casing together with FPFC

If required, the FODA can also be installed on top of a casing. See the steps and
Figure 222: Installing FODA on top of a casing. below.
a) Fix the mounting brackets to the casing with two screws. Fix the right-hand
mounting bracket first, using the side of the FODA to guide the installation.
b) Fix the left-hand mounting bracket. Note the installation direction of this bracket
in Figure 222: Installing FODA on top of a casing..
c) Fix the FODA on top of the casing with two screws on both sides.

Figure 222 Installing FODA on top of a casing.

3
2

1
3
2

190 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

10 Connect the optical cabling as required by the configuration.
Attach the connector seals to protect any unused connectors.

11 Install the front cover, if required.

15.2  Installing Flexi Fiber Optical Distribution unit
(FODA) on a wall
These instructions show how to install and connect the cabling of Flexi Fiber Optical
Distribution unit (FODA) for a wall installation.

Procedure

1 Open the lid of the FODA unit.
Open the lid of the FODA unit by removing the 14 M5 screws (TORX T25). See
Figure 223: Opening the lid of FODA, step 1.

Figure 223 Opening the lid of FODA

2 Remove the connector seals from the relevant optical cable connectors in the
FODA unit.
See Figure 223: Opening the lid of FODA, step 2. Store the seals for later use inside
the FODA.

Issue: 05 DN09142359 191


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

3 Route the input fiber cables via the cable gland.
First detach the nut from the cable gland and route the cables through the nut one by
one. Then route the cables through the cable gland.

Figure 224 Routing cables through the cable gland

Cable 12

12
11
10

9
8

5
4

3
2
1

Cable 1
2

192 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

4 Attach the input fiber cables to the relevant connectors inside the FODA.
The cables are numbered, so make sure to attach the cables to appropriate
connectors.

5 Tighten the cable gland to 0.7 Nm (0.5 ft-lb).
Make sure the cable IP sleeve is installed so that it goes through the gland as in
Figure 225: Tightening the cable gland.

Figure 225 Tightening the cable gland

Cable IP sleeve

6 Close the lid.
Fix the lid with 14 M5 screws. Tighten the plastic screws to 0.3 Nm (0.2 ft-lb).

7 Fix the mounting brackets on each side of the FODA.
Use a TORX T20 screwdriver.

Issue: 05 DN09142359 193


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 226 Fixing the mounting bracket and the cable tie bracket

8 Fix the cable tie bracket.
Fix the cable tie bracket on the same side as the cable gland to make cable routing
easier.

9 Attach the FODA unit on a wall using the mounting brackets.
Choose the correct screws according to the wall material.

194 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

Figure 227 Installing FODA on wall

10 Connect the optical cabling as required by the configuration.
Attach the connector seals to protect any unused connectors.

11 Route the cabling to the side of the unit using the cable tie bracket.

12 Attach the FODA front cover, if required.
See Figure 228: Installing the front cover for the steps.

Issue: 05 DN09142359 195


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 228 Installing the front cover

15.3  Installing Flexi Fiber Optical Distribution unit
(FODA) on a pole
These instructions show how to install Flexi Fiber Optical Distribution Unit (FODA)
472606A on a pole.

Procedure

1 Open the lid of the FODA unit.
Open the lid of the FODA unit by removing the 14 M5 screws (TORX T25). See
Figure 229: Opening the lid of FODA, step 1.

196 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

Figure 229 Opening the lid of FODA

2 Remove the connector seals from the relevant optical cable connectors in the
FODA unit.
See Figure 229: Opening the lid of FODA, step 2. Store the seals for later use inside
the FODA.

3 Route the input fiber cables via the cable gland.
First detach the nut from the cable gland and route the cables through the nut one by
one. Then route the cables through the cable gland.

Issue: 05 DN09142359 197


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 230 Routing cables through the cable gland

Cable 12

12
11
10

9
8

5
4

3
2
1

Cable 1
2

4 Attach the input fiber cables to relevant connectors inside the FODA.
The cables are numbered, so make sure to attach the cables to appropriate
connectors.

198 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

5 Tighten the cable gland to 0.7 Nm (0.5 ft-lb).
Make sure the cable IP sleeve is installed so that it goes through the gland as shown
in Figure 231: Tightening the cable gland.

Figure 231 Tightening the cable gland

Cable IP sleeve

6 Close the lid.
Fix the lid with 14 M5 screws. Tighten the plastic screws to 0.3 Nm (0.2 ft-lb).

7 Fix the mounting brackets on each side of the FODA.
Use a TORX T20 screwdriver.

Issue: 05 DN09142359 199


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 232 Fixing the mounting bracket and the cable tie bracket

8 Fix the cable tie bracket.
Fix the cable tie bracket on the same side as the cable gland to make cable routing
easier. See Figure 232: Fixing the mounting bracket and the cable tie bracket.

9 Connect the optical cabling as required by the configuration.
Attach the connector seals to protect any unused connectors.

10 Route the cabling to the side of the unit using the cable tie bracket.

11 Attach the FODA unit on the pole using the mounting brackets.
Use the straining straps included in the delivery to mount the FODA on the pole.

200 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Fiber Optical Distribution unit (FODA)
Multiradio 10 Base Station Optional Items

Figure 233 Installing FODA on a pole

12 Attach the FODA front cover.
See Figure 234: Installing the front cover for the steps.

Issue: 05 DN09142359 201


   

Installing Flexi Fiber Optical Distribution unit (FODA) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 234 Installing the front cover

202 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

16  Installing Flexi System External Alarm (FSEB)

16.1  Installing Flexi System External Alarm (FSEB)
Instructions for installing and connecting the cabling of Flexi System External Alarm
(FSEB).

Before you start
Flexi System External Alarm (FSEB) 471424A can be installed either horizontally (cable
lead-ins on the side) or vertically (cable lead-ins facing downwards, or left or right). See
the following figures for the two installation options.

Figure 235 FSEB installed horizontally

Issue: 05 DN09142359 203


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 236 FSEB installed vertically

In outdoor installations, the cable lead-ins must be facing downwards, left or right to
meet the IP55 standard.

Figure 237 FSEB connectors

ESD

Groundingpoint

EACM16
UltraSiteand Talk
swapcases
BTSinterconnection
cable

204 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

Figure 238 Fixing FSEB cables

(19.7in.)
500mm
max

Cablefixing

When the cable is routed down, tie the cable a maximum
of 500 mm (19.7 in) away from the FSEB to prevent the
weight of the cable to break the cable lead glands of the
FSEB.

Before installing the FSEB, see FSEB interface signals and connector pin assignments.
In pole or wall installations, locate the box in the proximity of the System Module. In wall
installations, make sure that the mounting surface is flat. The distance from the FSEB to
the System Module is limited by the length of the alarm cable.
If using Flexi Mounting Auxiliary Brackets (FMAA), see Figure 239: FMAA with FSEB for
the installation position of the FSEB on the module casing.

Issue: 05 DN09142359 205


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 239 FMAA with FSEB

FMAA FMAA

FSEB

FSEB

For FCIA and FCOA installations, use the fixing points on the cabinet roof.

Figure 240 FSEB fixing points on the FCIA roof

206 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

Figure 241 FSEB fixing points on the FCOA roof
1. 2.

3.

w NOTICE: Electrostatic discharge (ESD) might damage the equipment. Wear an ESD
wrist strap when handling the external alarm connection box.

When connecting the cables, make sure that the cable lead-ins that are not used are
blocked.
A module ground cable is not included in the FSEB delivery. The minimum cross-section
of the cable should be 2.5 mm2 (14 AWG). The length of the cable should be determined
based on the FSEB installation option (for example pole, wall, cabinet, or third-party
cabinet).

Issue: 05 DN09142359 207


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Procedure

1 Install the FSEB with four M5 screws using the fixing holes in the bottom of the
box.

Figure 242 Install FSEB with four M5 screws

Note that you do not need to open the box to install it.
In stack, wall or pole installation, install the FSEB using the mounting brackets. See
Installing Flexi Mounting Auxiliary Brackets (FMAA) for installation instructions.

2 Ground the box using the grounding screw on the right side of the FSEB front
plate.
Fix the nut tightly.

208 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

Figure 243 Connect the grounding cable

3 Connect the ESD wrist strap first to your wrist and then to the grounding clip
next to the grounding screw.

4 Open the lid of the FSEB box.
If using 12 alarms, set jumper X1103 to 12 Alarms mode. If using 24 alarms, set the
jumper to 24 Alarms mode.

Figure 244 Jumper X1103 in 12 Alarms mode

12 Alarms
24 Alarms

See Table 8: Alarms supported by System Module variants for the number of
supported alarms per technology.

Issue: 05 DN09142359 209


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 8 Alarms supported by System Module variants
     
System Module Alarms supported Requirements
variant

ESMA, ESMB, ESMC 24 N/A
FSMC, FSMD, FSME 24 FSEB v.304
(WCDMA)
WN6.0 MP3 or later

FSMD, FSME (LTE) 12 N/A
FSMF (WCDMA) 24 FSEB v.304
WN7.0 2.0 or later

FSMF (LTE) 12 N/A
FSMF (GSM/EDGE) 12 N/A

210 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

5 Connect the external alarms cable (included in the FSEB delivery) from the
FSEB to the System Module.

Figure 245 Connect the external alarms cable

a) Pull the left U-shaped cable gland from the FSEB box.
b) Remove the hole closing plug from the cable gland. If the plug is fixed with a
cable tie, cut the cable tie first and remove it.
c) Insert the cable in the cable gland. The D-Sub plug must point to the inside of the
box.
d) Connect the D-Sub plug to the leftmost D-Sub connector X1101 (ESM) on the
FSEB board.
e) Fix the connector fixing screws.
f) Insert the U-shaped cable gland to the front plate.
g) Insert the cable to the round rubber-seal in front of the U-shaped cable gland.
h) Fix the cable with a cable tie. Make sure that the U-gland fixes the cable tightly.
The cable must not move inside the gland.
i) Route the cable between the FSEB and System Module and fix it with cable ties.
The first fixing point must not be further away from the FSEB box than 0.5 m (1.6
ft).

Issue: 05 DN09142359 211


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

j) Remove the cover of the EAC connector on the System Module.
k) Insert the other end of the cable with the MDR-36 (FTSJ) or HDMI (FTSI)
connector to the EAC connector of the System Module. Make sure that the
connector is firmly in place.
l) Push the connector cover over the cable connector and seal the EAC connector
at the System Module with this cover.

6 If you are using an existing alarm cable (cable diameter min. 4-6 mm, ovality 1
mm) with a 37-pole D-Sub connector, connect the cable with a D-Sub
connector as follows:

t Tip:  These two alarm cables can be connected to the EACX-I and EACX-II connectors
of the FSEB, respectively. Connect the BTS alarm cables 1-12 and 13-24 to EACX-I
and EACX-II connectors. Note that signals ext_al 13...24 are considered in BTS
commissioning and fault handling as external alarms with IDs from 15 to 26. Pay
attention to connect them to the right EACX connector, otherwise the alarm number and
alarm description will not match. After the installation, trigger and verify the alarm
condition using the BTS Site Manager.

a) Pull the right U-shaped cable gland from the FSEB box.
b) Cut the cable tie off the cable gland.
c) Remove the hole closing plug from the cable gland.
d) Insert the alarm cable in the cable gland. The D-Sub plug must point to the inside
of the box.
e) Attach the D-Sub plug to the right 37-pole D-Sub connector X4101 (EACX-I port).
f) Fix the connector fixing screws.
g) Insert the U-shape cable gland to the front plate.
h) Insert the cable to the round rubber-seal in front of the U-shaped cable gland.
i) Fix the cable with a cable tie. Make sure that the U-gland fixes the cable tightly.
The cable must not move inside the gland.
j) Route the cable and fix it with cable ties. The first fixing point must not be further
away from the FSEB box than 0.5 m (1.6 ft).

7 If you are using the separate alarm cables, connect them to the screw
terminals as follows:

a) Tighten the cable gland nut.
The cable must not move inside the gland.
b) Insert the alarm cables in the FSEB box by using the cable glands on the right-
side half of the FSEB box.
c) Route the alarm cables and fix them with cable ties. The first fixing point must not
be further away from the FSEB box than 0.5 m (1.6 ft).
d) Attach alarm lines EXT_AL1 to EXT_AL12 using screw terminal blocks X4106-
X4109.

212 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

e) For each alarm input, connect one wire to the GROUND screw terminal blocks
X4107 or X4109 and connect one wire to the selected alarm input on screw
terminal blocks X4106 or X4108. The alarm inputs are marked on the FSEB
board with 'EXT_AL6 ... EXT_AL1' on X4106 and 'EXT_AL12 ... EXT_AL7' on
X4108.

t Tip:  If you use alarm inputs on the EACX-I port (D-Sub connector X4101), do not use
the same alarm inputs on the screw terminals X4106 and X4108.

8 If you are using the control output cables, connect them as follows:

a) Tighten the cable gland nut.
The cable must not move inside the gland.
b) Insert the control output cables in the FSEB box by using the cable glands on the
right-side half of the box.
c) Route the control cables and fix them with cable ties. The first fixing point must
not be further away from the FSEB box than 0.5 m (1.6 ft).
d) Attach the control lines EXT_CO1 to EXT_CO6 by using the screw terminal
blocks X4104 and X4105.
e) Control outputs are open collector type. Connect a pull-up resistor (2-6 kilohms, 5
kilohms is recommended) or an optocoupler to +5 V to ensure correct operation.
The control outputs are marked on the FSEB board with 'EXT_CO6 ... EXT_CO1'
on X4104.

Issue: 05 DN09142359 213


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 246 Control outputs
FSEB/SystemModule

+5V
PS OCP

RPullUp
2...6kOhm
600ohm
OVP Tocustomerapplication
EXT_CO1...EXTCO6
CTRL (Pins1...6)

EAXCI
EAC

FSEB/SystemModule

Optocoupler
OCP
+5V
PS

Tocustomerapplication

~160ohm
OVP
EXT_CO1...EXTCO6
CTRL (Pins1...6)

EAXCI
EAC

g Note:  If galvanic isolation is required for the customer application, see the figure above
for an example with an optocoupler. Follow the country-specific safety requirements.

t Tip:  If you use control outputs on the EACX-I port (D-Sub connector X4101), do not
use the same control outputs on the screw terminal X4104.

9 Install the fire detector to the FSEB (optional).

a) Connect the fire detector to the FSEB using a four-wire cable. Two wires are
needed for fire detector power supply and two for the fire detector alarm
connection.
b) Attach the four wires of the cable to the fire detector relay-base.
c) Insert the other end of the four wire cable through one cable gland at the right
half of the FSEB box.

214 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

d) Tighten the cable gland nut.
The cable must not move inside the gland.
e) Route the cable and fix it with cable ties. The first fixing point must not be further
away from the FSEB box than 0.5 m (1.6 ft).
f) Attach the wire marked with + from the fire detector to the leftmost or rightmost
opening of the screw terminal X4114.
g) Attach the wire marked with - from the fire detector to one of the four middle
openings of the screw terminal X4114 marked with GND.
See Fire detector power supply interface in FSEB interface signals and
connector pin assignments.
h) Attach the fire detector alarm wires to one of the alarm inputs 'EXT_AL12 ...
EXT_AL1'.

10 Install the cover of the FSEB box and tighten the eight screws to 1.7 Nm (1.25
ft-lb.).

Figure 247 Install the cover

Issue: 05 DN09142359 215


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

16.2  FSEB interface signals and connector pin
assignments
Figure 248 FSEB printed wiring board

EACX-II Fire Detector


Connector PowerSupplyoutput

ESM EACX-I Alarm Control 5VEAC


Connector Connector Inputs Outputs Output

Ground
Connections

EACX connector I pin assignment
Table 9 EACX connector I pin assignment (Sub-D37)
         
Pin Signal Pin Signal

1 EXT_CO1 19 GND

2 EXT_CO2 20 +5V/30mA

3 EXT_CO3 21 +5V/30mA

4 EXT_CO4 22 +5V/30mA

5 EXT_CO5 23 +5V/30mA

6 EXT_CO6 24 +5V/30mA

7 EXT_AL1 25 +5V/30mA

8 EXT_AL2 26 GND

9 EXT_AL3 27 GND

216 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

Table 9 EACX connector I pin assignment (Sub-D37) (Cont.)
         
Pin Signal Pin Signal

10 EXT_AL4 28 GND

11 EXT_AL5 29 GND

12 EXT_AL6 30 GND

13 EXT_AL7 31 GND

14 EXT_AL8 32 GND

15 EXT_AL9 33 GND

16 EXT_AL10 34 GND

17 EXT_AL11 35 GND

18 EXT_AL12 36 GND

- - 37 GND

EACX connector II pin assignment
EACX connector II is not used in the 12 Alarms mode.
Note that signals ext_al 13...24 are considered in BTS commissioning and fault handling
as external alarms with IDs from 15 to 26.

Table 10 EACX connector II pin assignment (Sub-D37)
         
Pin Signal Pin Signal

1 EXT_AL13 19 GND

2 EXT_AL14 20 GND

3 EXT_AL15 21 GND

4 EXT_AL16 22 GND

5 EXT_AL17 23 GND

6 EXT_AL18 24 GND

7 EXT_AL19 25 GND

8 EXT_AL20 26 GND

Issue: 05 DN09142359 217


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 10 EACX connector II pin assignment (Sub-D37) (Cont.)
         
Pin Signal Pin Signal

9 EXT_AL21 27 GND

10 EXT_AL22 28 GND

11 EXT_AL23 29 GND

12 EXT_AL24 30 GND

13 Not used 31 Not used

14 Not used 32 Not used

15 Not used 33 Not used

16 Not used 34 Not used

17 Not used 35 Not used

18 Not used 36 Not used

- - 37 Not used

Screw terminal pin assignment
Table 11 Screw terminal pin assignment
         
Signal Screw Signal Screw
terminal terminal1)

EXT_CO1 Connector +5V Connector


X4104 pin 1 X4105 pin 1

EXT_CO2 Connector +5V Connector


X4104 pin 2 X4105 pin 2

EXT_CO3 Connector +5V Connector


X4104 pin 3 X4105 pin 3

EXT_CO4 Connector +5V Connector


X4104 pin 4 X4105 pin 4

EXT_CO5 Connector +5V Connector


X4104 pin 5 X4105 pin 5

EXT_CO6 Connector +5V Connector


X4104 pin 6 X4105 pin 6

218 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

Table 11 Screw terminal pin assignment (Cont.)
         
Signal Screw Signal Screw
terminal terminal1)

EXT_AL1 Connector GND Connector


X4106 pin 1 X4107 pin 1

EXT_AL2 Connector GND Connector


X4106 pin 2 X4107 pin 2

EXT_AL3 Connector GND Connector


X4106 pin 3 X4107 pin 3

EXT_AL4 Connector GND Connector


X4106 pin 4 X4107 pin 4

EXT_AL5 Connector GND Connector


X4106 pin 5 X4107 pin 5

EXT_AL6 Connector GND Connector


X4106 pin 6 X4107 pin 6

EXT_AL7 Connector GND Connector


X4108 pin 1 X4109 pin 1

EXT_AL8 Connector GND Connector


X4108 pin 2 X4109 pin 2

EXT_AL9 Connector GND Connector


X4108 pin 3 X4109 pin 3

EXT_AL10 Connector GND Connector


X4108 pin 4 X4109 pin 4

EXT_AL11 Connector GND Connector


X4108 pin 5 X4109 pin 5

EXT_AL12 Connector GND Connector


X4108 pin 6 X4109 pin 6

EXT_AL13 Connector GND Connector


X4110 pin 1 X4111 pin 1

EXT_AL14 Connector GND Connector


X4110 pin 2 X4111 pin 2

EXT_AL15 Connector GND Connector


X4110 pin 3 X4111 pin 3

EXT_AL16 Connector GND Connector


X4110 pin 4 X4111 pin 4

Issue: 05 DN09142359 219


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 11 Screw terminal pin assignment (Cont.)
         
Signal Screw Signal Screw
terminal terminal1)

EXT_AL17 Connector GND Connector


X4110 pin 5 X4111 pin 5

EXT_AL18 Connector GND Connector


X4110 pin 6 X4111 pin 6

EXT_AL19 Connector GND Connector


X4112 pin 1 X4113 pin 1

EXT_AL20 Connector GND Connector


X4112 pin 2 X4113 pin 2

EXT_AL21 Connector GND Connector


X4112 pin 3 X4113 pin 3

EXT_AL22 Connector GND Connector


X4112 pin 4 X4113 pin 4

EXT_AL23 Connector GND Connector


X4112 pin 5 X4113 pin 5

EXT_AL24 Connector GND Connector


X4112 pin 6 X4113 pin 6

1)The X connectors are marked on the bottom of the FSEB PCB.

Fire detector power supply interface
Table 12 Fire detector power screw terminal X4114 pin assignment
   
Pin Signal

1 +8.55V ...
+11.5V

2 Ground

3 Ground

4 Ground

5 Ground

6 +8.55V ...
+11.5V

220 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi System External Alarm (FSEB)
Multiradio 10 Base Station Optional Items

16.3  EAC cable (FTSI 472578A) wiring
Table 13 EAC cable (FTSI) wiring
       
Conn. 1 (HDMI) Conn. 2 (D37) Pair: wire color Description
Pin no. Pin no.

1 7 1: Black EXT_AL0_H

2 8 2: Brown EXT_AL1_H

3 9 1: White/Black EXT_AL2_H

4 10 2: White/ Brown EXT_AL3_H

5 11 3: Red EXT_AL4_H

6 12 4: Orange EXT_AL5_H

7 1 + 13 3: White/Red EXT_CTRL0_EXT_AL


6_H

8 2 + 14 4: White/Orange EXT_CTRL1_EXT_AL


7_H

9 3 + 15 5: Yellow EXT_CTRL2_EXT_AL


8_H

10 4 + 16 6: Green EXT_CTRL3_EXT_AL


9_H

11 5 + 17 5: White/Yellow EXT_CTRL4_EXT_AL


10_H

12 6 + 18 6: White/Green EXT_CTRL5_EXT_AL


11_H

13 19 7: Blue P5V0_EAC

14 20 7: White/Blue P5V0_EAC

15 23 8: Violet PROT_CAN_H_P5V_
EAC

16 27 9: Grey GND

17 24 8: White/Violet PROT_CAN_L_P5V_
EAC

18 25 10: Pink GND

Issue: 05 DN09142359 221


   

Installing Flexi System External Alarm (FSEB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 13 EAC cable (FTSI) wiring (Cont.)
       
Conn. 1 (HDMI) Conn. 2 (D37) Pair: wire color Description
Pin no. Pin no.

19 28 9: White/Grey GND

222 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing GPS GLONASS Receiver Antenna (FYGB)
Multiradio 10 Base Station Optional Items

17  Installing GPS GLONASS Receiver Antenna
(FYGB)
Instructions for installing GPS GLONASS Receiver Antenna (FYGB) 472748A using
GPS Mounting Kit (FYMA) 471605A.

Purpose
The following GPS (Global Positioning System)/GNSS (Global Navigation Satellite
System) items are available:

• GPS GLONASS Receiver Antenna (FYGB) 472748A
• Optional items:
– GPS Mounting Kit (FYMA) 471605A

– Flexi GPS Surge Protection Kit (FYEA) 471812A
– Power/data cables:
• GPS cable set (FYHA) up to 30 m 471606A
• GPS cable set (FYHB) up to 100 m 471653A
• GPS cable set (FTSE) up to 30 m 472510A (for System Module variant
FSMF)
• GPS cable set (FTSH) up to 100 m 472577A (for System Module variant
FSMF)

Issue: 05 DN09142359 223


   

Installing GPS GLONASS Receiver Antenna (FYGB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 249 GPS hardware

FTSE

FTSH

FYGB

FTSM

FYHA

FYMA

FYHB

Follow the general guidelines for locating the GPS/GNSS antenna to provide safe and
clear satellite visibility. See section Satellite visibility below for more details.
Satellite visibility
Note that a 180º clear sky view is the optimum case from the signal quality and accuracy
point of view. If the clear sky view is smaller than 180º (for example urban canyons), the
GPS/GNSS receiver operation might suffer from poor satellite visibility, depending on the
sky view angle and location on the globe (especially latitude). The GPS/GNSS receiver
might be operational, especially after the survey, even with smaller than a 180º sky view,
however, this cannot be guaranteed. Furthermore, the survey time might be longer and
the accuracy of the PPS signal poorer than with a full 180º sky visibility.

224 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing GPS GLONASS Receiver Antenna (FYGB)
Multiradio 10 Base Station Optional Items

Figure 250 GPS view
GPSview
GPS GPS
GPS satellite GPS satellite
satellite satellite

GPS GPS
satellite satellite

180 180

GPSantenna GPSantenna

Withproperskyview(satellitevisibility) Aftersurvey:Onesatelliteisenough
thesurveytimeislessthan60minutes. fortheGPSreceivertoprovidethe
PPSreferencesignalfortheBTS.
ThePPSaccuracywithonlyone
Note:Goodconstellation
satelliteis,however,poorerthan
(i.e.aPPsqualitysignal)requires4-5
withalargernumberofsatellites
visiblesatellites,dependingonthe
(i.e.withgoodskyvisibility).
satelliteconstellationsituation.In
practiceitmeansa180openview.

Procedure

1 Install the GPS Mounting Kit (FYMA).

a) To attach the kit to a wall, use the screws.
Figure 251 Installing the GPS/GNSS system on the wall

1a

b) To attach the kit to a pole, use the fixing band.

Issue: 05 DN09142359 225


   

Installing GPS GLONASS Receiver Antenna (FYGB) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 252 Installing the GPS/GNSS system on the pole

1b

The following table presents the GPS/GNSS pole mounting band cutting rule.
Table 14 GPS/GNSS pole mounting band cutting rule
   
Pole diameter Cutting length

50 mm (1.9 in) 107 mm (4.2 in)

80 mm (3.1 in) 201 mm (7.9 in)

110 mm (4.3 in) 296 mm (11.6 in)

150 mm (5.9 in) 421 mm (16.5 in)

200 mm (7.8 in) 578 mm (22.7 in)

250 mm (9.8 in) 804 mm (31.6 in)

300 mm (11.8 in) 893 mm (35.1 in)

Note that the 25 mm (0.9 in) bending lengths for both ends are included in the
cutting lengths.
The metal band folds must be inwards folded and so that folds are compressed
against the pole while tightening the band.

226 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing GPS GLONASS Receiver Antenna (FYGB)
Multiradio 10 Base Station Optional Items

Figure 253 Pole mounting band
Metalband
Wormscrew
Wormscrewhousing

Lockingrack

t Tip:  To ease the tightening of the band, locate the worm screw on the other side of the
pole than the fastener.

2 Attach the GPS/GNSS receiver to the mounting kit.

3 Connect the GPS/GNSS receiver cable to the GPS/GNSS receiver.

4 Route the cable through the holes in the mounting kit.

5 Secure the cable with the cable ties.

6 Connect the other end of the GPS/GNSS cable to the Sync In port on the
System Module front panel.

Result

Figure 254 Pole mounting

Issue: 05 DN09142359 227


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 103 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

18  Installing Flexi GPS Surge Protection Kit
(FYEA) v. 103
These instructions show how to install Flexi GPS Surge Protection Kit (FYEA) 471812A
v. 103. The assembly protects the Flexi System Module against transient voltage and
current spikes in the GPS antenna line.

Before you start
There are two mounting kits for the FYEA:

• Flexi Mounting Auxiliary Brackets (FMAA) for stack installations
• Flexi Pole Installation Kit (FPIA) for pole and wall installations

The FYEA enclosure is connected between the System Module and the GPS antenna.
The FYEA can also be installed on FCOA roof. The fixing points on the cabinet roof are
illustrated in the following figure.

Figure 255 FYEA fixing points on the FCOA roof

1. 2. 3.

Procedure

1 Install the FYEA enclosure on the mounting kit and then install the mounting
kit.
In outdoor installations, the FYEA must be installed maximum 10 meters (33 ft.) from
the System Module. Note that the length of the GPS cable is 30 m (98 ft.), 100
metres (328 ft.) or 300 m (984 ft.).
For pole installations, use Flexi Pole Installation Kit (FPIA):
a) Thread the straining straps to the installation plate.
b) Tighten the straining straps around the pole.

228 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Surge Protection Kit (FYEA) v. 103
Multiradio 10 Base Station Optional Items

Figure 256 Installing FPIA

Issue: 05 DN09142359 229


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 103 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

2 Open the lid of the FYEA enclosure.

Figure 257 Opening the FYEA v. 103 lid

3 Connect the grounding cable.
Route the grounding cable from the bottom right corner of the FYEA enclosure to the
grounding point on the plinth.

Figure 258 Connecting the grounding cable (FYEA v. 103)

230 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Surge Protection Kit (FYEA) v. 103
Multiradio 10 Base Station Optional Items

4 Cut the GPS cable.
Cut the GPS cable and remove around 70 mm (2.76 in) of the cable jacket and 8 mm
(0.31 in) of the wire covering.

Issue: 05 DN09142359 231


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 103 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 259 Exposing the wires

8mm
(0.31in)

70mm(2.76in)

5 Remove the gland nuts and IP plugs.

6 Thread the cable through the gland nuts.

7 Connect the cables to the FYEA enclosure.
Connect the wires to the FYEA enclosure in the following way:

Table 15 FYEA connections
       
Pair Color Position OUT (to Position IN (to
number GPS antenna) System Module)

4 Brown 1 2

White 3 4

3 Green 7 8

White 9 10

2 Orange 11 12

232 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Surge Protection Kit (FYEA) v. 103
Multiradio 10 Base Station Optional Items

Table 15 FYEA connections (Cont.)
       
Pair Color Position OUT (to Position IN (to
number GPS antenna) System Module)

White 13 14

1 Blue 17 18

White 19 20

Figure 260 Connecting cables (FYEA v. 103)
ToGPS Antenna

OUT

OUT
19 17 15 13 11 9 7 5 3 1

20 18 16 14 12 10 8 6 4 2

IN
IN

FromSystemModule

Issue: 05 DN09142359 233


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 103 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

8 Tighten the gland nuts to 2.5 Nm (1.84 ft.lb.).

9 Route the GPS cables to the System Module and to the GPS antenna
respectively.

10 Check the FYEA connections and close the lid.

Figure 261 Closing the FYEA v. 103 lid

11 Connect the GPS cable ends to the System Module and GPS antenna
respectively.

234 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Surge Protection Kit (FYEA) v. 104
Multiradio 10 Base Station Optional Items

19  Installing Flexi GPS Surge Protection Kit
(FYEA) v. 104
These instructions show how to install Flexi GPS Surge Protection Kit (FYEA) 471812A
v. 104. The assembly protects the Flexi System Module against transient voltage and
current spikes in the GPS antenna line.

Before you start
There are two mounting kits for the FYEA:

• Flexi Mounting Auxiliary Brackets (FMAA) for stack installations
• Flexi Pole Installation Kit (FPIA) for pole and wall installations

The FYEA enclosure is connected between the System Module and the GPS antenna.
The FYEA can also be installed on FCOA roof. The fixing points on the cabinet roof are
illustrated in the following figure.

Figure 262 FYEA fixing points on the FCOA roof

1. 2. 3.

Procedure

1 Install the FYEA enclosure on the mounting kit and then install the mounting
kit.
In outdoor installations, the FYEA must be installed maximum 10 m (33 ft.) from the
System Module. Note that the length of the GPS cable is 30 m (98 ft.), 100 metres
(328 ft.) or 300 m (984 ft.).
For pole installations, use Flexi Pole Installation Kit (FPIA):
a) Thread the straining straps to the installation plate.
b) Tighten the straining straps around the pole.

Issue: 05 DN09142359 235


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 104 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 263 Installing FPIA

236 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Surge Protection Kit (FYEA) v. 104
Multiradio 10 Base Station Optional Items

2 Undo the M5 screws with a TX25 screwdriver and open the lid of the FYEA
enclosure.

Figure 264 Opening the FYEA v. 104 lid

3 Connect the grounding cable.
Route the grounding cable from the bottom right corner of the FYEA enclosure to the
grounding point on the plinth.

Issue: 05 DN09142359 237


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 104 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 265 Connecting the grounding cable (FYEA v. 104)

4 Cut the GPS cable.
Cut the GPS cable and remove around 70 mm (2.76 in) of the cable jacket and 8 mm
(0.31 in) of the wire covering.

238 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Surge Protection Kit (FYEA) v. 104
Multiradio 10 Base Station Optional Items

Figure 266 Exposing the wires

8mm
(0.31in)

70mm(2.76in)

5 Remove the gland nuts and IP plugs.

6 Thread the cable through the gland nuts.

7 Connect the cables to the FYEA enclosure.
Connect the wires to the FYEA enclosure in the following way:

Table 16 FYEA connections
       
Pair Color Position OUT (to Position IN (to
number GPS antenna) System Module)

4 Brown 1 2

White 3 4

3 Green 7 8

White 9 10

2 Orange 11 12

Issue: 05 DN09142359 239


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 104 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 16 FYEA connections (Cont.)
       
Pair Color Position OUT (to Position IN (to
number GPS antenna) System Module)

White 13 14

1 Blue 17 18

White 19 20

Figure 267 Connecting cables (FYEA v. 104)
ToGPS Antenna

OUT

OUT

19 17 15 13 11 9 7 5 3 1

20 18 16 14 12 10 8 6 4 2

IN

IN

FromSystemModule

240 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Surge Protection Kit (FYEA) v. 104
Multiradio 10 Base Station Optional Items

8 Tighten the gland nuts (Hex socket, size 19 mm) to 2.5 Nm (1.84 ft.lb.).

9 Route the GPS cables to the System Module and to the GPS antenna
respectively.

10 Check the FYEA connections and close the lid.
Tighten the M5 screws to 4.5 - 5.0 Nm (3.3 - 3.7 ft.lb.)

Figure 268 Closing the FYEA v. 104 lid

Issue: 05 DN09142359 241


   

Installing Flexi GPS Surge Protection Kit (FYEA) v. 104 Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

11 Connect the GPS cable ends to the System Module and GPS antenna
respectively.

242 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Box (FYGD)
Multiradio 10 Base Station Optional Items

20  Installing Flexi GPS Box (FYGD)
These instructions show how to install Flexi GPS Box (FYGD) 472802A.

Before you start

g Note:  Note that Flexi GPS Box (FYGD) is IP20-rated and for indoor site use only.

If cable entries are installed, remove them.
See Figure 269: Flexi GPS Box (FYGD) front panel (v. 102) for external interfaces of
FYGD.

Figure 269 Flexi GPS Box (FYGD) front panel (v. 102)
HDMI

GNSS
SMA
Female
RJ45 RJ45

GNSS SyncOut 1588 In 1588 Out 1588 Status PWR On/Off


Ant

Procedure

1 Remove the FPFD dummy unit as follows:

a) Undo the screws holding the FSMF core in place.
b) Pull out the core.
c) Remove the three screws holding the FPFD dummy unit in place.

g Note:  Leave the other dummy units in place if you are not installing any other optional
sub-modules.

Issue: 05 DN09142359 243


   

Installing Flexi GPS Box (FYGD) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 270 Removing dummy unit

a)

b)

c)

2 Fix the FYGD to the FSMF core.
FYGD is fixed with the three screws that are included in the FYGD delivery. See
figure below.

244 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi GPS Box (FYGD)
Multiradio 10 Base Station Optional Items

Figure 271 Fixing FYGD to core

3 Re-insert the module core and fix the screws.

4 Connect the 1PPS source from the GNSS antenna to GNSS ANT connector.

Figure 272 1PPS connection

5 Connect the 1PPS sync cable from the Sync Out connector to the Sync In
connector on the FSMF on which the FYGD is installed.
Use the 0.6 m (2 ft.) cable.

Issue: 05 DN09142359 245


   

Installing Flexi GPS Box (FYGD) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 273 Connecting sync cable

6 If required, switch the timing resource.
FYGD uses GNSS as default setting for the timing resource, but if required, the 1588
setting can be selected using the switch on the FYGD front panel.

7 Switch the FYGD On.

246 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

21  Installing Flexi Enhanced External GNSS Box
(FYGE)

21.1  Installing Flexi Enhanced External GNSS Box
(FYGE) inside Flexi System Module (FSMF)
These instructions show how to install a Flexi Enhanced External GNSS Box (FYGE)
472978A.

Before you start

g Note:  Note that Flexi Enhanced External GNSS Box (FYGE) is IP20-rated and for
indoor site use only.

If cable entries are installed, remove them.
See Figure 274: Flexi Enhanced External GNSS Box (FYGE) front panel for external
interfaces of FYGE.

Figure 274 Flexi Enhanced External GNSS Box (FYGE) front panel
HDMI

-48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

Procedure

1 Remove the FPFD dummy unit as follows:

a) Undo the screws holding the FSMF core in place.
b) Pull out the core.
c) Remove the three screws holding the FPFD dummy unit in place.

g Note:  Leave the other dummy units in place if you are not installing any other optional
sub-modules.

Issue: 05 DN09142359 247


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 275 Removing dummy unit

a)

b)

c)

248 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

2 Fix the FYGE to the FSMF core with three screws.

Figure 276 Fixing FYGE to core

3 Re-insert the module core and fix the screws holding the module core in place.

4 Connect the 1PPS source from the GNSS antenna (GPS Antenna 40dB Nf Kit
(FYGR) 473076A) to GNSS ANT connector. Tighten to 0.45 Nm (0.33 ft-lb).

Figure 277 1PPS connection
HDMI

-48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

Issue: 05 DN09142359 249


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

5 Connect the HDMI cable (included in the delivery) from the Sync Out connector
to the Sync In connector on the FSMF on which the FYGE is installed.
Use the 0.8 m (2.6 ft.) HDMI cable.

Figure 278 Connecting sync cable

HDMI -48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

6 Connect the power cable (included in the delivery) to the DC In port.
The other end of the cable is open-ended. Connect the black wire to 0V and red wire
to -48V.

Figure 279 Connecting power cable
HDMI

-48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

21.2  Installing FYGE inside of FCOB
Follow these instructions when installing Flexi Enhanced External GPS Box (FYGE)
inside of the FCOB.

250 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

Purpose

Figure 280 FYGE installed inside of an FCOB

Before you start
For more detailed information on FYGE, see Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items Description.

g Note:  The installation instructions for FYGE have not been fully verified.

Issue: 05 DN09142359 251


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Procedure

1 Remove the four M5 screws and pull out the dummy casing.

Figure 281 Removing four M5 screws and pulling out the dummy casing

2 Change the dummy casing small plate position.
Sub-steps

a) Loosen the small plate middle M4 screw and remove the side M4 screw.

b) Rotate the small plate by 90 degrees.

c) Fix the small plate side M4 screw and tighten the middle M4 screw.
Tighten the M4 screws to 2.2 Nm (19.5 in-lb).

252 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

Figure 282 Changing the dummy casing small plate position

!
2.2 Nm
!

3 Install the FYGE into the dummy casing with three M5x35 screws.
Tighten the M5 screws to 4.3 Nm (38.0 in-lb).

g Note:  M5x35 screws are included in FYGE delivery.

Issue: 05 DN09142359 253


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 283 Installing FYGE into the dummy casing

!
4.3 Nm
!

4 Reinsert and reinstall the dummy casing with FYGE into the FCOB using four
M5 screws.
Tighten the M5 screws to 4.3 Nm (38.0 in-lb).
Figure 284 Reinserting and reinstalling the dummy casing with FYGE into the
FCOB

!
4.3 Nm
!

254 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

5 Prepare the FYGE power cables.

g Note:  It is recommended to strip 10 mm of the power cable.

Figure 285 Preparing the FYGE power cables

10mm

10mm

6 Connect the power cables to the PDU and FYGE.

Figure 286 Connecting power cables to FYGE

21.3  Installing FYGG inside of FCOB
Follow these instructions when installing OD External GNSS Enhanced Holdover
(FYGG) inside of the FCOB.

Issue: 05 DN09142359 255


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Purpose

Figure 287 FYGG installed inside of an FCOB

Before you start
For more detailed information on FYGG, see Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items Description.

Procedure

1 Remove the four M5 screws and pull out the dummy casing.

Figure 288 Removing four M5 screws and pulling out the dummy casing

256 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

2 Change the dummy casing small plate position.
Sub-steps

a) Loosen the small plate middle M4 screw and remove the side M4 screw.

b) Rotate the small plate by 90 degrees.

c) Fix the small plate side M4 screw and tighten the middle M4 screw.
Tighten the M4 screws to 2.2 Nm (19.5 in-lb).

Issue: 05 DN09142359 257


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 289 Changing the dummy casing small plate position

!
2.2 Nm
!

3 Install the FYGG into the dummy casing with three M5x8 screws.
Tighten the M5 screws to 4.3 Nm (38.0 in-lb).

g Note:  M5x8 screws are included in FYGG delivery.

258 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

Figure 290 Installing FYGG into the dummy casing

!
4.3 Nm
!

4 Reinsert and reinstall the dummy casing with FYGG into the FCOB using four
M5 screws.
Tighten the M5 screws to 4.3 Nm (38.0 in-lb).

Issue: 05 DN09142359 259


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 291 Reinserting and reinstalling the dummy casing with FYGG into the
FCOB

!
4.3 Nm
!

5 Prepare the FYGG power cables.

g Note:  It is recommended to strip 10 mm (0.20 in.) of the power cable.

260 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

Figure 292 Preparing the FYGG power cables

10mm

10mm

6 Connect the power cables to the PDU and FYGG.

Figure 293 Connecting power cables to FYGG

21.4  Installing Flexi Enhanced External GNSS Box
(FYGE) on a 19-inch rack
These instructions show how to install a Flexi Enhanced External GNSS Box (FYGE)
472978A on a 19-inch rack.

Issue: 05 DN09142359 261


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Before you start

g Note:  Note that Flexi Enhanced External GNSS Box (FYGE) is IP20-rated and for
indoor site use only.

See Figure 294: Flexi Enhanced External GNSS Box (FYGE) front panel for external
interfaces of FYGE.

Figure 294 Flexi Enhanced External GNSS Box (FYGE) front panel

HDMI
-48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

Mounting ears on the sides of the 1U casing are movable. There are four different
positions for the ears. Use the positions that best suit your configuration.

Procedure

1 Insert the FYGE into its decicated slot inside the 1U casing.

2 On the outside of 1U casing, fix the FYGE in place with three screws.

3 Insert the 1U casing into the cabinet or 19-inch rack.

Figure 295 1U casing on 19-inch rack
HDMI

-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

262 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

4 Fix the 1U casing to the cabinet or 19-inch rack with one M6x12 Torx head
screw on each side.
Preferably use the lower fixing points of the 1U casing.
Figure 296 1U casing fixing points

HDMI
-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

5 Connect the 1PPS source from the GNSS antenna (GPS Antenna 40dB Nf Kit
(FYGR) 473076A) to GNSS ANT connector. Tighten to 0.45 Nm (0.33 ft-lb).

Figure 297 Connecting GNSS cabling
HDMI

-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

Issue: 05 DN09142359 263


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

6 Connect the HDMI cable (included in the delivery) from the Sync Out connector
to the Sync In connector on the FSIH front panel.
Use the 0.8 m (2.6 ft.) HDMI cable.

Figure 298 Connecting sync cable

HDMI
-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

7 Connect the power cable (included in the delivery) to the DC In port.
The other end of the cable is open-ended. Connect the black wire to 0V and red wire
to -48V.

Figure 299 Connecting power cable
HDMI

-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

21.5  Installing Flexi Enhanced External GNSS Box
(FYGE) on top of Flexi System Module (FSIH)
These instructions show how to install a Flexi Enhanced External GNSS Box (FYGE)
472978A on top of Flexi System Module (FSIH).

Before you start

g Note:  Note that Flexi Enhanced External GNSS Box (FYGE) is IP20-rated and for
indoor site use only.

264 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

See Figure 300: Flexi Enhanced External GNSS Box (FYGE) front panel for external
interfaces of FYGE.

Figure 300 Flexi Enhanced External GNSS Box (FYGE) front panel

HDMI
-48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

Mounting ears on the sides of the 1U casing are movable. There are four different
positions for the ears. Use the positions that best suit your configuration.

Issue: 05 DN09142359 265


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Procedure

1 Insert the FYGE into its decicated slot inside the 1U casing.

2 On the outside of 1U casing, fix the FYGE in place with three screws.

3 Fix two connection pins (821513A, included in the accessory bag) onto the
FSIH casing.

4 Place the 1U casing on top of the FSIH casing aligning the connection pins
inside the keyholes of the 1U casing.

5 Tighten the two screws inside the 1U casing with an L-shaped T25 torx key.

Figure 301 FYGE installed on top of FSIH

266 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

6 Connect the 1PPS source from the GNSS antenna (GPS Antenna 40dB Nf Kit
(FYGR) 473076A) to GNSS ANT connector. Tighten to 0.45 Nm (0.33 ft-lb).

Figure 302 Connecting GNSS cabling

HDMI
-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

7 Connect the HDMI cable (included in the delivery) from the Sync Out connector
to the Sync In connector on the FSIH front panel.
Use the 0.8 m (2.6 ft.) HDMI cable.

Figure 303 Connecting sync cable
HDMI

-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

8 Connect the power cable (included in the delivery) to the DC In port.
The other end of the cable is open-ended. Connect the black wire to 0V and red wire
to -48V.

Issue: 05 DN09142359 267


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 304 Connecting power cable

HDMI
-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

21.6  Installing Flexi Enhanced External GNSS Box
(FYGE) below Flexi System Module (FSIH)
These instructions show how to install a Flexi Enhanced External GNSS Box (FYGE)
472978A in a module stack below Flexi System Module (FSIH).

Before you start

g Note:  Note that Flexi Enhanced External GNSS Box (FYGE) is IP20-rated and for
indoor site use only.

See Figure 305: Flexi Enhanced External GNSS Box (FYGE) front panel for external
interfaces of FYGE.

Figure 305 Flexi Enhanced External GNSS Box (FYGE) front panel
HDMI

-48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

Mounting ears on the sides of the 1U casing are movable. There are four different
positions for the ears. Use the positions that best suit your configuration.

268 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

Procedure

1 Insert the FYGE into its decicated slot inside the 1U casing.

2 On the outside of 1U casing, fix the FYGE in place with three screws.

3 Knock off the keyholes on the bottom of the FSIH casing.

Figure 306 Knocking off FSIH keyholes

Issue: 05 DN09142359 269


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

4 Place the FSIH casing on top of the 1U casing aligning the connection pins
inside the keyholes of the FSIH casing.

Figure 307 FYGE below FSIH

270 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

5 Loosen the two screws of FSIH core by hand and pull out the core.

6 Tighten the screws with an L-shaped T25 torx key.

7 Reinsert the FSIH core and hand-tighten the screws.

8 Connect the 1PPS source from the GNSS antenna (GPS Antenna 40dB Nf Kit
(FYGR) 473076A) to GNSS ANT connector. Tighten to 0.45 Nm (0.33 ft-lb).

Figure 308 Connecting GNSS cabling

HDMI
-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

9 Connect the HDMI cable (included in the delivery) from the Sync Out connector
to the Sync In connector on the FSIH front panel.
Use the 0.8 m (2.6 ft.) HDMI cable.

Figure 309 Connecting sync cable
HDMI

-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

10 Connect the power cable (included in the delivery) to the DC In port.
The other end of the cable is open-ended. Connect the black wire to 0V and red wire
to -48V.

Issue: 05 DN09142359 271


   

Installing Flexi Enhanced External GNSS Box (FYGE) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 310 Connecting power cable

HDMI
-48V 0V

GNSS ANT SYNCOUT STATUS POWER DCIN

21.7  Installing Flexi Enhanced External GNSS Box
(FYGE) on the wall
These instructions show how to install a Flexi Enhanced External GNSS Box (FYGE)
472978A on the wall.

Before you start

g Note:  Note that Flexi Enhanced External GNSS Box (FYGE) is IP20-rated and for
indoor site use only.

See Figure 311: Flexi Enhanced External GNSS Box (FYGE) front panel for external
interfaces of FYGE.

Figure 311 Flexi Enhanced External GNSS Box (FYGE) front panel
HDMI

-48V 0V
SMA
Female

GNSS ANT SYNCOUT STATUS POWER DC IN

272 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Enhanced External GNSS Box (FYGE)
Multiradio 10 Base Station Optional Items

Procedure

1 Insert the FYGE into its decicated slot inside the 1U casing.

2 On the outside of 1U casing, fix the FYGE in place with three screws.

3 Drill holes for wall mounting.
The distance between the holes is 420 mm.
Figure 312 FYGE 1U casing wall mounting points
420mm(16.54in)

4 Insert M6 screws in the holes and tighten the screws, leaving the heads of the
screws approximately raised 2 mm off the wall.

5 Hang the 1U casing on the wall (FYGE front panel facing down) using the two
keyholes at the bottom of the 1U casing.

Issue: 05 DN09142359 273


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

22  Installing OD External GNSS Enhanced
Holdover (FYGG)

22.1  Installing OD External GNSS Enhanced Holdover
(FYGG) inside Flexi System Module (FSMF)
These instructions show how to install an OD External GNSS Enhanced Holdover
(FYGG) 473185A in the top left slot inside the FSMF casing.

Before you start
If cable entries are installed, remove them.
See Figure 313: OD External GNSS Enhanced Holdover (FYGG) front panel for external
interfaces of FYGG.

Figure 313 OD External GNSS Enhanced Holdover (FYGG) front panel

PWR

GNSS ANT
STATUS
SYNCOUT DCIN

Procedure

1 Remove the FPFD dummy unit as follows:

a) Undo the screws holding the FSMF core in place.
b) Pull out the core.
c) Remove the three screws holding the FPFD dummy unit in place.

g Note:  Leave the other dummy units in place if you are not installing any other optional
sub-modules.

274 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

Figure 314 Removing dummy unit

a)

b)

c)

Issue: 05 DN09142359 275


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

2 Fix the FYGG to the FSMF core with three screws. Tighten the screws to 4.0
Nm (2.95 ft-lbs).

Figure 315 Fixing FYGG to core

3 Re-insert the module core and fix the screws holding the module core in place.

4 Connect the RF source from the GNSS antenna to the GNSS ANT connector.
Tighten to 0.45 Nm (0.33 ft-lb).

Figure 316 Connecting GNSS cabling

276 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

5 Connect the GNSS sync HDMI-HDMI cable OD 0.8m cable (995821A, included in
the delivery) from the FYGG Sync Out connector to the Sync In connector on
the FSMF on which the FYGG is installed.

Figure 317 Connecting sync cable

6 Connect the GNSS Power cable OD 0.8m (995823A, included in the delivery)
between the FYGG DC In port and FSMF DC Out port.

Figure 318 Connecting power cable

22.2  Installing OD External GNSS Enhanced Holdover
(FYGG) on a 19-inch rack
These instructions show how to install an OD External GNSS Enhanced Holdover
(FYGG) 473185A on a 19-inch rack.

Before you start
See Figure 319: OD External GNSS Enhanced Holdover (FYGG) front panel for external
interfaces of FYGG.

Issue: 05 DN09142359 277


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

Figure 319 OD External GNSS Enhanced Holdover (FYGG) front panel

PWR

GNSS ANT
STATUS
SYNCOUT DCIN

Mounting ears on the sides of the 1U casing are movable. There are four different
positions for the ears. Use the positions that best suit your configuration.

Procedure

1 Insert the FYGG into its decicated slot inside the 1U casing.

2 On the outside of 1U casing, fix the FYGG in place with three screws.

3 Insert the 1U casing into the cabinet or 19-inch rack.

Figure 320 1U casing on 19-inch rack

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

4 Fix the 1U casing to the cabinet or 19-inch rack with one M6x12 Torx head
screw on each side.
Preferably use the lower fixing points of the 1U casing.

278 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

Figure 321 1U casing fixing points

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

5 Connect the RF source from the GNSS antenna to the GNSS ANT connector.
Tighten to 0.45 Nm (0.33 ft-lb).

Figure 322 Connecting GNSS cabling

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

Issue: 05 DN09142359 279


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

6 Connect the GNSS sync HDMI-HDMI cable OD 0.8m cable (995821A, included in
the delivery) from the FYGG Sync Out connector to the Sync In connector on
the System Module front panel.

Figure 323 Connecting sync cable

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

7 Connect the GNSS Power cable OD 0.8m (995823A, included in the delivery) to
the FYGG DC In port.
Cut the cable connector off the other end of the cable. Connect the black wire to 0V
and blue wire to -48V.

Figure 324 Connecting power cable

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

22.3  Installing OD External GNSS Enhanced Holdover
(FYGG) on top of Flexi System Module (FSIH)
These instructions show how to install an OD External GNSS Enhanced Holdover
(FYGG) 473185A stacked on top of a Flexi System Module (FSIH).

Before you start
See Figure 325: OD External GNSS Enhanced Holdover (FYGG) front panel for external
interfaces of FYGG.

280 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

Figure 325 OD External GNSS Enhanced Holdover (FYGG) front panel

PWR

GNSS ANT
STATUS
SYNCOUT DCIN

Mounting ears on the sides of the 1U casing are movable. There are four different
positions for the ears. Use the positions that best suit your configuration.

Issue: 05 DN09142359 281


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

Procedure

1 Insert the FYGG into its decicated slot inside the 1U casing.

2 On the outside of 1U casing, fix the FYGG in place with three screws.

3 Fix two connection pins (821513A, included in the accessory bag) onto the
FSIH casing.

4 Place the 1U casing on top of the FSIH casing aligning the connection pins
inside the keyholes of the 1U casing.

5 Tighten the two screws inside the 1U casing with an L-shaped T25 torx key.

Figure 326 FYGG installed on top of FSIH

DCIN

282 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

6 Connect the RF source from the GNSS antenna to the GNSS ANT connector.
Tighten to 0.45 Nm (0.33 ft-lb).

Figure 327 Connecting GNSS cabling

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

7 Connect the GNSS sync HDMI-HDMI cable OD 0.8m cable (995821A, included in
the delivery) from the FYGG Sync Out connector to the Sync In connector on
the FSIH front panel.

Figure 328 Connecting sync cable

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

8 Connect the GNSS Power cable OD 0.8m (995823A, included in the delivery) to
the FYGG DC In port.
Cut the cable connector off the other end of the cable. Connect the black wire to 0V
and blue wire to -48V.

Issue: 05 DN09142359 283


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

Figure 329 Connecting power cable

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

22.4  Installing OD External GNSS Enhanced Holdover
(FYGG) below Flexi System Module (FSIH)
These instructions show how to install an OD External GNSS Enhanced Holdover
(FYGG) 473185A in a module stack below Flexi System Module (FSIH).

Before you start
See Figure 330: OD External GNSS Enhanced Holdover (FYGG) for external interfaces
of FYGG.

Figure 330 OD External GNSS Enhanced Holdover (FYGG)

PWR

GNSS ANT
STATUS
SYNCOUT DCIN

Mounting ears on the sides of the 1U casing are movable. There are four different
positions for the ears. Use the positions that best suit your configuration.

284 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

Procedure

1 Insert the FYGG into its decicated slot inside the 1U casing.

2 On the outside of 1U casing, fix the FYGG in place with three screws.

3 Knock off the keyholes on the bottom of the FSIH casing.

Figure 331 Knocking off FSIH keyholes

Issue: 05 DN09142359 285


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

4 Place the FSIH casing on top of the 1U casing aligning the connection pins
inside the keyholes of the FSIH casing.

Figure 332 FYGG below FSIH

DCIN

286 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

5 Loosen the two screws of FSIH core by hand and pull out the core.

6 Tighten the screws with an L-shaped T25 torx key.

7 Reinsert the FSIH core and hand-tighten the screws.

8 Connect the RF source from the GNSS antenna to the GNSS ANT connector.
Tighten to 0.45 Nm (0.33 ft-lb).

Figure 333 Connecting GNSS cabling

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

9 Connect the GNSS sync HDMI-HDMI cable OD 0.8m cable (995821A, included in
the delivery) from the FYGG Sync Out connector to the Sync In connector on
the FSIH front panel.

Figure 334 Connecting sync cable

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

10 Connect the GNSS Power cable OD 0.8m (995823A, included in the delivery) to
the FYGG DC In port.
Cut the cable connector off the other end of the cable. Connect the black wire to 0V
and blue wire to -48V.

Issue: 05 DN09142359 287


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

Figure 335 Connecting power cable

SYNCOUT POWER

DCIN
GNSS ANT
HDMI STATUS

22.5  Installing OD External GNSS Enhanced Holdover
(FYGG) on the wall
These instructions show how to install an OD External GNSS Enhanced Holdover
(FYGG) 473185A on the wall.

Before you start
See Figure 336: OD External GNSS Enhanced Holdover (FYGG) front panel for external
interfaces of FYGG.

Figure 336 OD External GNSS Enhanced Holdover (FYGG) front panel

PWR

GNSS ANT
STATUS
SYNCOUT DCIN

Procedure

1 Insert the FYGG into its decicated slot inside the 1U casing.

2 On the outside of the 1U casing, fix the FYGG in place with three screws.

3 Drill holes for wall mounting.
The distance between the holes is 420 mm.

288 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

Figure 337 FYGG 1U casing wall mounting points
420mm(16.54in)

4 Insert M6 screws in the upper holes and tighten the screws, leaving the heads
of the screws raised approximately 2 mm off the wall.

5 Hang the 1U casing on the wall (FYGG front panel facing down) using the two
keyholes at the bottom of the 1U casing.

6 Secure the 1U casing to the wall with screws using the two lower holes.

7 Connect the cables as shown in previous chapters.

22.6  Installing OD External GNSS Enhanced Holdover
(FYGG) on the pole
These instructions show how to install OD External GNSS Enhanced Holdover (FYGG)
473185A on a pole.

Before you start
See Figure 338: OD External GNSS Enhanced Holdover (FYGG) front panel for external
interfaces of FYGG.

Issue: 05 DN09142359 289


   

Installing OD External GNSS Enhanced Holdover Installing Flexi Multiradio Base Station and Flexi
(FYGG) Multiradio 10 Base Station Optional Items

Figure 338 OD External GNSS Enhanced Holdover (FYGG) front panel

PWR

GNSS ANT
STATUS
SYNCOUT DCIN

Procedure

1 While on the ground, thread hose clamps through the two sets of slots on the
FYGG installation tray.

Figure 339 Threading hose clamps

290 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing OD External GNSS Enhanced Holdover
Multiradio 10 Base Station Optional Items (FYGG)

2 Position FYGG on the pole with its front panel facing down.

3 Wrap the hose clamps around the pole and thread them through the worm
screw assembly.

Figure 340 Installing FYGG on pole

4 Tighten the worm screw assemblies.

5 Connect the cables as shown in previous chapters.

6 Fix any excess cabling securely to the pole to prevent movement.

Issue: 05 DN09142359 291


   

Installing Flexi Filters (FFNT/FFNU) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

23  Installing Flexi Filters (FFNT/FFNU)

23.1  Installing Flexi Filters (FFNT/FFNU) on the pole
Instructions for installing Flexi Filter B40 PassB=2305-2315MHz (FFNT) 473061A or
Flexi Filter B40 PassB=2350-2360MHz (FFNU) 473062A on a pole.

Procedure

1 While on the ground, thread the hose clamps through the two slots on each
mounting bracket.

Figure 341 Threading hose clamps

BTS5

BTS6

BTS7

BTS8

ANT5

ANT6

ANT7

ANT8

292 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Filters (FFNT/FFNU)
Multiradio 10 Base Station Optional Items

2 Position the filter on the pole with ANT connectors facing up.

Figure 342 Filter on the pole

BTS1 BTS2 BTS3 BTS4

FFHS

ANT1 GND ANT2 ANT3 ANT4

Issue: 05 DN09142359 293


   

Installing Flexi Filters (FFNT/FFNU) Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

3 Wrap the hose clamps around the pole and thread them through the worm
screw assembly.

4 Tighten the worm screw assemblies.

Figure 343 Hose clamps

! repeateduse
notallowed

Torque 5-6Nm(3.5-4.5ft-lbs)

forpolesrangingindiameterfrom45mmto120mm(1.77to4.72in)

5 Connect the grounding cable.

6 Remove connector caps from the BTS/ANT ports that you are going to use.
Leave the connector caps in place for any unused BTS/ANT ports.

7 Connect antenna jumper cables between the BTS ports of the filter and radio
unit.
Tighten to 10 Nm (7.38 ft-lbs)

8 Connect jumper cables from the ANT ports of the filter to antenna feeder
cables.

9 Check that the connectors are correctly mated and securely fastened.
Make sure that the bend radius of the cables do not place stress on the cable or
connectors.

294 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Flexi Filters (FFNT/FFNU)
Multiradio 10 Base Station Optional Items

10 Make sure that any excess cabling is securely fixed to the pole to prevent
movement.

23.2  Installing Flexi Filters (FFNT/FFNU) on the wall
Instructions for installing Flexi Filter B40 PassB=2305-2315MHz (FFNT) 473061A or
Flexi Filter B40 PassB=2350-2360MHz (FFNU) 473062A on a wall.

Procedure

1 Using the filter as a template, mark the screw hole locations on the wall.
There are two sets of mounting holes on the brackets. Use the outer set of holes for
M6-sized screws (6 mm/0.24 in) and the inner set of holes for M8 (8 mm/0.32 in).

2 Drill the holes.

3 Position the filter on the wall with ANT connectors facing up.

4 Fix with screws or bolts.

5 Proceed with cabling as instructed in Installing Flexi Filters (FFNT/FFNU) on
the pole.

Issue: 05 DN09142359 295


   

Installing Cable Holder for Flexi System Module 10 Installing Flexi Multiradio Base Station and Flexi
indoor FSIH/FBIH (FCHB) Multiradio 10 Base Station Optional Items

24  Installing Cable Holder for Flexi System
Module 10 indoor FSIH/FBIH (FCHB)
These instructions show how to install Cable Holder for Flexi System Module 10 indoor
FSIH/FBIH (FCHB) for a floor or wall installation.

Procedure

1 Depending on your cable routing, fix a FCHB assembly on the left or right side
of the FSIH casing with two screws.

2 If necessary, install another FCHB assembly on the other side of the FSIH
casing.

Figure 344 Installing FCHB

296 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Installing Cable Holder for Flexi System Module 10
Multiradio 10 Base Station Optional Items indoor FSIH/FBIH (FCHB)

3 Fix the DC cable clamp to any suitable location on the FCHB.

4 Thread the DC cable through the cable clamp and fix the two screws.

Figure 345 FSIH wall installation with two FCHBs

5 Fix any other cables onto the FCHB using cable ties.

Issue: 05 DN09142359 297


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

25  Appendix Contents of deliveries

25.1  Contents of the System Extension Kit (FSKA)
delivery
The System Extension Kit (FSKA) delivery contains the following items:

Table 17 System Extension Kit (FSKA) delivery contents
     
Description Product code Quantity

Flexi System Extension Kit (FSKA) 471226A 1

Accessories for FSKA: 1

• Optical cable, 2m (6.6 ft.) 2

• Power cable, 2m (6.6 ft.) 1

• Optical transceiver 4

Transmission dummy panel 1

M5 x 25 screw 4

25.2  Contents of the Flexi Pole Installation Kit (FPIA)
delivery
Table 18 Flexi Pole Installation Kit (FPIA) delivery contents
     
Description Product code Quantity

Flexi Pole Installation Kit (FPIA): 471767A 1

• Installation plate 1

• Straining strap 1

• M5x16 screws 4

See the following figure for more information on the delivery contents.

298 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Figure 346 FPIA delivery contents

25.3  Contents of the Flexi Mounting Auxiliary Bracket
(FMAA)
Table 19 Flexi Mounting Auxiliary Bracket (FMAA) delivery contents
     
Description Product code Quantity

Flexi Mounting Auxiliary 471657A
Bracket (FMAA):

• Bracket 1

• M5 x 16 screw 8

• M5 x 10 screw 4

• M5 spring washer 4

See the following figure for more information on the delivery contents.

Issue: 05 DN09142359 299


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 347 FMAA delivery contents

25.4  Contents of the 3U mounting covers (FMCA)
delivery
The front and back covers are an optional item that has to be ordered separately, when
needed. The covers delivery contains the following items:

Table 20 3U mounting covers (FMCA) delivery contents
     
Description Product code Quantity

3U mounting covers (FMCA) 470239A 1

• 3U front cover 1

• 3U back cover 1

• Maintenance straps 2

• Grounding cable 1.3 m (51.2 in) 1

• 3U cable entries 2

• Cable entry screws (M5 x 10) 4

See the following figure for more information on the delivery content.

300 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Figure 348 FMCA delivery contents
Frontcover Backcover

2xcableentry

2xmaintenancestrap Groundingcable

25.5  Contents of the Flexi 3U High Covers Mounting
Covers Front/back (FMCH) delivery
This section lists the hardware delivery contents of Flexi 3U High Covers Mounting
Covers Front/back (FMCH) 473186A.

The front and back covers are an optional item that has to be ordered separately, when
needed. The covers delivery contains the following items:

Table 21 Flexi 3U High Covers Mounting Covers Front/back (FMCH) delivery
contents
     
Description Product code Quantity

3U mounting covers (FMCH) 473186A 1

• 3U front cover 1

• 3U back cover 1

• Maintenance straps 2

• Grounding cable 1.3 m (51.2 in) 1

• 3U cable entries 2

• Cable entry screws (M5 x 10) 4

Issue: 05 DN09142359 301


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 21 Flexi 3U High Covers Mounting Covers Front/back (FMCH) delivery
contents (Cont.)
     
Description Product code Quantity

• Stress relief corpus 1

• Cable clamp range 8 - 28 mm 1

• Cable clamp screws (M5 x 50) 2

See Figure 349: FMCH delivery contents for more information on the delivery content.

Figure 349 FMCH delivery contents
Backcover

Frontcover

2xcableentry

2xmaintenancestrap Groundingcable

stress reliefcorpus
cableclamp

302 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

25.6  Contents of the Flexi Mounting Covers Front and
Back, 2U (FMCB) delivery
Table 22 Flexi Mounting Covers Front and Back, 2U (FMCB), needed with Flexi
Power DC/ DC Module 24 V (FPDA)
     
Description Product code Quantity

Flexi Mounting Covers Front and Back, 2U (FMCB) 470332A 1

• 2U front cover 1

• 2U back cover 1

• Maintenance straps 2

• Grounding cable 1.3 m (51.2 in) 1

• 2U cable entries 2

• Cable entry screws M5x10 4

See the following figure for more information on the delivery content.

Figure 350 FMCB delivery contents
Frontcover Backcover

2xcableentry

2xmaintenancestrap Groundingcable

Issue: 05 DN09142359 303


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

25.7  Contents of the 3U Module Casings (EMHA)
delivery
The 3U Module Casings (EMHA) delivery contains the following items:

Table 23 Flexi Module Casings for 3U modules (EMHA) delivery contents
     
Description Product code Quantity

EMHA 470316A 1

3U casing 1

• 3U cable entries 2

• 3U front cover 1

• 3U rear cover 1

• M5 x 10 screws 4

• M5 x 8 screws 2

• Cage nuts 6
(2 loose, 4 preinstalled)

• Maintenance straps 2
(1 loose, 1 preinstalled)

• Grounding cable 1.3 1
m (51.2 in)

• Cable clamps 2

• K30 screws for 4
cable clamps

304 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Figure 351 EMHA delivery contents

25.8  Contents of the Flexi 3U Casing and High Covers
F&B (EMHH) delivery
This section lists the hardware delivery contents of Flexi 3U Casing and High Covers
F&B (EMHH) 473187A.

The Flexi 3U Casing and High Covers F&B (EMHH) delivery contains the following
items:

Table 24 Flexi 3U Casing and High Covers F&B (EMHH) delivery contents
     
Description Product code Quantity

EMHH 473187A 1

3U casing 1

• 3U cable entries 2

• 3U front cover 1

• 3U rear cover 1

Issue: 05 DN09142359 305


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 24 Flexi 3U Casing and High Covers F&B (EMHH) delivery contents (Cont.)
     
Description Product code Quantity

• M5 x 10 screws 4

• M5 x 8 screws 2

• Cage nuts 6
(2 loose, 4 preinstalled)

• Maintenance straps 2
(1 loose, 1 preinstalled)

• Grounding cable 1.3 1
m (51.2 in)

• Cable clamps 2

• K30 screws for 4
cable clamps

Figure 352 EMHH delivery contents

25.9  Contents of the 2U Module Casings (EMTA) delivery
The 2U Module Casings (EMTA) delivery contains the following items:

306 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Table 25 Flexi Module Casings for 2U modules (EMTA) delivery contents
     
Description Product code Quantity

EMTA 470315A 1

2U casing 1

• 2U cable entries 2

• 2U front cover 1

• 2U rear cover 1

• M5 x 10 screws 4

• M5 x 8 screws 2

• Cage nuts 4, preinstalled

• Maintenance straps 2
(1 loose, 1 preinstalled)

• Grounding cable 1.3 1
m (51.2 in)

• Cable clamps 2

• K30 screws for cable 4
clamps

Issue: 05 DN09142359 307


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 353 EMTA delivery contents

25.10  Contents of the Flexi Side Covers (FMHA) delivery
Flexi Side Covers (FMHA) for 3 height units (3U) delivery contains the following items:

Table 26 Flexi Side Covers (FMHA) delivery contents
     
Description Product code Quantity

Flexi Side Covers (FMHA) 471524A 1

• 3U Cable Tunnel Cover side 2

• 3U Cable Tunnel Cover front 2

• M5 x 10 PT screws (self-tapping) 4
for fixing cover to 2U cable entry
(plastics)

308 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Table 26 Flexi Side Covers (FMHA) delivery contents (Cont.)
     
Description Product code Quantity

• M5 x 10 screws for fixing side 4
cover to 2U cable entry (metal)

• M5 Torx captive screws 2

Figure 354 FMHA delivery contents

25.11  Contents of the Flexi Side Covers (FMTA) delivery
Flexi Side Covers (FMTA) for 2 height units (2U) delivery contains the following items:

Table 27 Flexi Side Covers (FMTA) delivery contents
     
Description Product code Quantity

Flexi Side Covers (FMTA) 471523A 1

• 2U Cable Tunnel Cover side 2

• 2U Cable Tunnel Cover front 2

• M5 x 10 self-tapping screws 4

• M5 Torx captive screws 2

Issue: 05 DN09142359 309


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 355 FMTA delivery contents

25.12  Contents of the Flexi Power Module (FPMA)
delivery
The FPMA Power Module is an optional item that has to be ordered separately, when
needed.

Table 28 Flexi Power Module (FPMA) delivery contents
     
Description Product code Quantity

Power Module (FPMA) with internal 470139A 1
AC and DC cabling and cable support
plates

• Alarm cable to the System 1
Module, 2 m (6.6 ft.)

• Power cable harness, 30, 40, 50 1
and 80 cm (11.8, 15.7, 19.7 and
31.5 inches)

• Power cable, 1.2 m (4 ft.) 2

• Power cable L, 10 cm (4 inches) 3

• Cable clamps 2

• K30 screws for the cable clamps 4

310 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Table 28 Flexi Power Module (FPMA) delivery contents (Cont.)
     
Description Product code Quantity

• M5x8 screws for fixing the casing 2
to another casing or plinth

• Cable ties 10

• Air deflector 1

• 5x10 PT screws (self-tapping) for 2
fixing the air deflector to the 3U
front cover

See the following figure for more information on the delivery contents.

Figure 356 FPMA delivery contents

10x

25.12.1  Contents of the power AC/DC sub-module (FPAA) delivery
The FPAA power sub-module is an optional item that has to be ordered separately, when
needed.

Issue: 05 DN09142359 311


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 29 FPAA power sub-module delivery contents
     
Description Product code Quantity

Power sub-module (FPAA) with two 470140A 1
RJ-45 connector seal caps installed

• Alarm cable 1

• M5 screws for fixing the FPAA to 2
FPMA

See the following figure for more information on the delivery contents.

Figure 357 FPAA delivery contents

25.12.2  Contents of the power battery sub-module (FPBB) delivery
The FPBB power battery sub-module is an optional item that has to be ordered
separately, when needed.

Table 30 FPBB power sub-module delivery contents
     
Description Product code Quantity

Power battery sub-module (FPBB) 472113A 1
with two RJ-45 connector seal caps
installed

• Alarm cable 0.2 m (7.9 in) 1

• M5x12 screws for fixing the FPBB 2
to FPMA

See the following figure for more information on the delivery contents.

312 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Figure 358 FPBB delivery contents

25.13  Contents of the 24V Power Module (FPDA) delivery
The 24V Power Module (FPDA) is an optional item that has to be ordered separately,
when needed.

Table 31 24V Power Module (FPDA) delivery contents
     
Description Product code Quantity

DC/DC converter core pre-installed 470067A 1
inside a 2U casing with two RJ-45
connector seal caps installed

• DC output power cables 1.2 m 2
(3.94 ft)

• Alarm cable 2 m (6.56 ft) 1

• 4 AWG (25 mm2) connector 4
single rubber boot

• M5x8 screws for fixing the 2
casings to each other

• Cable clamps 4

• K30 screws for cable clamps 8

See the following figure for more information on the delivery contents.

Issue: 05 DN09142359 313


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 359 FPDA delivery contents

25.14  Contents of the Flexi Power AC/DC sub-module
(FPAD) delivery
The Flexi Power AC/DC sub-module (FPAD) delivery contains the following item:

Table 32 Flexi Power AC/DC sub-module (FPAD) delivery contents
     
Description Product code Quantity

Flexi Power AC/DC sub-module 472805A 1
(FPAD)

Figure 360 FPAD delivery contents

314 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

25.15  Contents of the Flexi Power AC/DC sub-module
(FPAE) delivery
The Flexi Power AC/DC sub-module (FPAE) delivery contains the following item:

Table 33 Flexi Power AC/DC sub-module (FPAE) delivery contents
     
Description Product code Quantity

Flexi Power AC/DC sub-module 472953A 1
(FPAE)

M5 x 14 screws 5
(3 pcs for
fixing FPAE
on RRH or
wall, 2 pcs for
grounding)

Figure 361 FPAE delivery contents

25.16  Contents of the Flexi Power Distribution and Fuses
Outdoor (FPFC) (Efore) delivery
This section lists the hardware delivery contents of Flexi Power Distribution and Fuses
Outdoor (FPFC) (Efore) 472508A.

Table 34 Flexi Power Distribution and Fuses Outdoor (FPFC) (Efore) delivery
contents
     
Description Product code Quantity

Flexi Power Distribution and Fuses 472508A 1
Outdoor (FPFC)

Issue: 05 DN09142359 315


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 34 Flexi Power Distribution and Fuses Outdoor (FPFC) (Efore) delivery
contents (Cont.)
     
Description Product code Quantity

• Washers 4

• Cable clamps 2

• Grounding cable 1.3 m (4.27 ft) 1

• Alarm cable 2 m (6.56 ft) 1

• Maintenance straps 2

• M5 x 10 screws for fixing cable 7
entries and grounding cable. Also
two screws can be used as lock
screws in casing installation

• K30 screws for cable clamps 4

• M5 x 6 screws for fixing two 2
casings together

• M5 screws for fixing FPFC to 2U 4
casing

Figure 362 FPFC delivery contents

316 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

25.17  Contents of the Flexi Power Distribution and Fuses
Outdoor (FPFC) (AcBel) delivery
This section lists the hardware delivery contents of Flexi Power Distribution and Fuses
Outdoor (FPFC) (AcBel) 472508A.

Table 35 Flexi Power Distribution and Fuses Outdoor (FPFC) (AcBel) delivery
contents
     
Description Product code Quantity

Flexi Power Distribution and Fuses 472508A 1
Outdoor (FPFC)

• Washers 4

• Cable clamps 2

• Grounding cable 1.3 m (4.27 ft) 1

• Alarm cable 2 m (6.56 ft) 1

• Maintenance straps 2

• M5 x 10 screws for fixing cable 7
entries and grounding cable. Also
two screws can be used as lock
screws in casing installation

• K30 screws for cable clamps 4

• M5 x 6 screws for fixing two 2
casings together

• M5 screws for fixing FPFC to 2U 4
casing

Issue: 05 DN09142359 317


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 363 FPFC delivery contents

25.18  Contents of the Flexi System External OVP (FSES)
delivery
The Flexi System External OVP (FSES) delivery contains the following items:

Table 36 Flexi System External OVP (FSES) delivery contents
     
Description Product code Quantity

Flexi System External OVP (FSES) 472285A 1
with a pre-installed power output and
grounding cable

• Screws (M5 x 8) 4

318 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Figure 364 FSES delivery contents

25.19  Contents of the Flexi System External OVP (FSEP)
delivery
This section lists the delivery contents of Flexi System External OVP (FSEP).

The Flexi System External OVP (FSEP) delivery contains the following items:

Table 37 Flexi System External OVP (FSEP) delivery contents
     
Description Product code Quantity

Flexi System External OVP (FSEP) 473246A 1
with a factory-installed grounding
cable and DC connector IP boots

• Screws (M5 x 8) 4

IP boot for alarm cable 1

Issue: 05 DN09142359 319


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 365 FSEP delivery contents

25.20  Contents of the Flexi Fiber Optical Distribution unit
(FODA) delivery
The Flexi Fiber Optical Distribution unit (FODA) is an optional item that has to be ordered
separately when needed.

Table 38 Flexi Fiber Optical Distribution unit (FODA) delivery contents
     
Description Product code Quantity

Flexi Fiber Optical Distribution unit 472606A 1
(FODA)

• Front cover 1

• Mounting bracket 2

• Cable tie bracket 1

• M4 x 12 screws 6

• Spring washers 6

• M5 screws 2

• M6 self-locking screws for wall 4
mounting

• Clamps 2

320 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Figure 366 FODA delivery contents

25.21  Contents of the Flexi System External Alarm
Module (FSEB)
Table 39 Flexi System External Alarm Module (FSEB) delivery contents
     
Description Product code Quantity

Flexi System External Alarm 471424A 1
Module (FSEB):

• D37 Cable Assembly 1

• Cable tie, PER31 3

Issue: 05 DN09142359 321


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 367 FSEB delivery contents

3x

25.22  Contents of the GPS hardware deliveries
Hardware delivery contents of GPS Mounting Kit (FYMA) 471605A, GPS GLONASS
Receiver Antenna (FYGB) 472748A and GPS cable deliveries
(FYHA/FYHB/FTSE/FTSH/FTSM).

GPS hardware deliveries are presented as follows:

• Table 40: GPS Mounting Kit (FYMA) delivery contents (always needed)
• Table 41: GPS GLONASS Receiver Antenna (FYGB) delivery contents

g Note:  GPS GLONASS Receiver Antenna (FYGB) can be only used with the System
Module variant FSMF.

• Table 42: GPS cable deliveries (FYHA/FYHB/FTSE/FTSH/FTSM) (choose one
according to your System Module variant and cable length required)
• Contents of the Flexi GPS Surge Protection Kit (FYEA) delivery (in case surge
protection is required)

Table 40 GPS Mounting Kit (FYMA) delivery contents
     
Description Product code Quantity

GPS Mounting Kit (FYMA) 471605A 1

• Fixing band 1

• Cable tie 1

322 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Table 41 GPS GLONASS Receiver Antenna (FYGB) delivery contents
     
Description Product code Quantity

GNSS Antenna Kit (FYGB) 472748A 1

Table 42 GPS cable deliveries (FYHA/FYHB/FTSE/FTSH/FTSM)
     
Description Product code Quantity

GPS Cable, 30 m (98.4 ft.) (FYHA) 471606A 1

GPS Cable, 100 m (328 ft.) (FYHB) 471653A 1

GPS Cable, 30 m (98.4 ft.) (FTSE) 472510A 1

GPS Cable, 100 m (328 ft.) (FTSH) 472577A 1

GPS Cable, 300 m (984 ft.) (FTSM) 472870A 1

For Flexi GPS Surge Protection Kit (FYEA) delivery contents, see Contents of the Flexi
GPS Surge Protection Kit (FYEA) delivery.
GPS hardware items are shown in Figure 368: GPS hardware.

Issue: 05 DN09142359 323


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 368 GPS hardware

FTSE

FTSH

FYGB

FTSM

FYHA

FYMA

FYHB

25.23  Contents of the Flexi GPS Surge Protection Kit
(FYEA) delivery
Hardware items delivered with Flexi GPS Surge Protection Kit (FYEA) 471812A.

The Flexi GPS Surge Protection Kit (FYEA) delivery contains the following items:

Table 43 Flexi GPS Surge Protection Kit (FYEA) delivery contents
     
Description Product code Quantity

Flexi GPS Surge Protection Kit 471812A 1
(FYEA)

324 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

Table 43 Flexi GPS Surge Protection Kit (FYEA) delivery contents (Cont.)
     
Description Product code Quantity

• Grounding cable 1.3 m (4.27 ft) 1

• M5 x 16 screw 4

Figure 369 FYEA delivery contents

25.24  Contents of the GPS Box (FYGD) delivery
The GPS Box (FYGD) delivery contains the following items:

Table 44 GPS Box (FYGD) delivery contents
     
Description Product code Quantity

GPS Box (FYGD) 472802A 1

• HDMI Sync cable, 0.6 m (2 ft.) 1

• Screws for fixing the FYGD 3

Issue: 05 DN09142359 325


   

Appendix Contents of deliveries Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Figure 370 FYGD delivery contents

25.25  Contents of the Flexi Enhanced External GPS Box
(FYGE) delivery
The Flexi Enhanced External GPS Box (FYGE) delivery contains the following items:

Table 45 Flexi Enhanced External GPS Box (FYGE) delivery contents
     
Description Product code Quantity

Flexi Enhanced External GPS Box 472978A 1
(FYGE)

• HDMI Sync cable, 0.8 m 1

• Power cable, 2 m 1

Table 46 FYGE Mounting 1U Casing delivery contents
     
Description Product code Quantity

FYGE Mounting 1U Casing 473039A 1

M5 captive nuts (SBM 173 050/03) 6
M5X12 screws (Torx head, AISI 316 6
stainless steel)
M5X6 screws (Torx head, AISI 316 2
stainless steel)

326 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Contents of deliveries
Multiradio 10 Base Station Optional Items

25.26  Contents of the OD External GNSS Enhanced
Holdover (FYGG) delivery
The OD External GNSS Enhanced Holdover (FYGG) delivery contains the following
items:

Table 47 OD External GNSS Enhanced Holdover (FYGG) delivery contents
     
Description Product code Quantity

OD External GNSS Enhanced 473185A 1
Holdover (FYGG)

• GNSS sync HDMI-HDMI cable 995821A 1
OD 0.8m

• GNSS Power cable OD 0.8m 995823A 1

• Screws 3

25.27  Contents of the Flexi Filter (FFNT/FFNU) deliveries
Flexi Filter (FFNT/FFNU) deliveries contain the following items:

Table 48 Flexi Filter B40 PassB=2305-2315MHz (FFNT) delivery contents
Description Product code Quantity
Flexi Filter B40 PassB=2305- 473061A 1
2315MHz (FFNT)

Hose clamps for pole 2
installation

Table 49 Flexi Filter B40 PassB=2350-2360MHz (FFNU) delivery contents
Description Product code Quantity
Flexi Filter B40 PassB=2350- 473062A 1
2360MHz (FFNU)

Hose clamps for pole 2
installation

Issue: 05 DN09142359 327


   

Appendix Installation tools and torque values Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

26  Appendix Installation tools and torque values

26.1  BTS installation tools and equipment
This section lists the installation tools and equipment.

Table 50 Tools for installation
 
Installation tools

Allen key: 8 mm (0.31 in.)

ESD wrist strap and cable

TORX screwdriver set: T10, T20, T25

Screwdriver set: Phillips 0 , 1, 2 and flathead

Wrench 13 mm (0.51 in.)

Folding knife

Monkey wrench

Side cutters

Scissors

Crimping tool for 16 mm² (6 AWG) grounding cable

Torque wrench for antenna cables

Lint-free swab or wipe and 99% alcohol for cleaning optical connectors

Cable ties for routing cables

Tape measure

Flashlight, pocket lamp or torch

Hammer drill

Marker pen or comparable tool

Pliers

Saw

Lubricant for cables

328 DN09142359 Issue: 05


   

Installing Flexi Multiradio Base Station and Flexi Appendix Installation tools and torque values
Multiradio 10 Base Station Optional Items

26.2  Torque values
Table with torque values for the BTS recommended by Nokia.

Nokia strongly recommends the following torque values for the various different bolts and
screws (assuming that lubricant has been applied). Use these values unless stated
otherwise.

Table 51 Torque values for the BTS
       
Bolt/Screw Type DIN Size Torque

TORX head screw 7985 F1-60 M3 0.7 - 1.0 Nm


cylinder head
(0.52 - 0.74 ft-lb)

TORX head screw 7985 F1-60 M4 1.2 - 1.6 Nm


cylinder head
(0.89 - 1.18 ft-lb)

TORX head screw 7985 F1-60 M5 2.0 - 2.5 Nm


cylinder head
(1.48 - 1.84 ft-lb)

TORX head PT 5x10 WN1452 5x10 mm 2.0 Nm (1.48 ft-lb)


mm
TORX head screw 7985 F1-60 M8 10.0 Nm
cylinder head
(7.38 ft-lb)

Hexagon head screw 933-12-70 M12 49.0 Nm


(cabinet fixing)
(36.14 ft-lb)

Allen screw 912-A2-70 M8 8.0 - 10.0 Nm


(5.90 - 7.38 ft-lb)

Nut 934 A2 M5 3.7 Nm


(2.73 ft-lb)

Nut (cabinet fixing) 934 A2 M12 49.0 Nm


(36.14 ft-lb)

FPKA/FPKC screw 933 M8x20 20.0 Nm (14.75 ft-


lb)

Fan fixing screws, - M4 0.7 Nm
plastic
(0.52 ft-lb)

Fan fixing screws, - M4 1.2 Nm
metal

Issue: 05 DN09142359 329


   

Appendix Installation tools and torque values Installing Flexi Multiradio Base Station and Flexi
Multiradio 10 Base Station Optional Items

Table 51 Torque values for the BTS (Cont.)
       
Bolt/Screw Type DIN Size Torque

(0.89 ft-lb)

330 DN09142359 Issue: 05