Verticalcm (4 983)

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 6

Design of Pile Foundation

Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]

Type of Based on Bore


Name of Project: Soil Investigation Amritsar MNB Location 4+983 A1 Pile Cut-off level (m) 2.00
Structure Hole

Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1000 1 3 (m)
Coefficient Ks Resistance

Liquefaction depth below cut-off level (m) 0

Bearing Ultimate Base Resistance Ultimate Shaft Friction


Capacity Factors Ppu = Ap (cNc + PdNq + 0.5gDNg) PSU = (Ʃ(Ks.Pdi.tand). Asi + a.c.As)
Total/ Total
Angle of g
Submerg Effective Ultimate Total Safe Capacity, Total safe
Type of Thickness Length Water (densit Effective Weight of Pile
Cohesion, Shearing ed Unit overburden Capacity, PS (Tonnes) uplift
Layer no. Sub Soil of Layer from Cut table pile, WP Length
C (t/m2) Resistance y of Weight Pressure at pile tip over PU = Ppu + capacity
Layer (m) off level (W.T.) (m) soil) burden (Tonnes) (m)
, f (deg.) of Soil "qtip" (t/m2) Ap 0.5.g.D.N Ppu Asi (Ks.Pdi.tand).A Adhesion PSU PSU PS = PU/3 - WP (Tonnes)
(t/m3) Nc Nq Ng c.Nc Pd.Nq Pressure at a.c.As
(t/m3) (m2) g (tonnes) (m2) si Factor, a (tonnes) (tonnes)
c.g. of the
layer 'Pdi'
(t/m2)

1 SM 4 2.00 14.00 0 29 1.820 0.84 7.28 28 16.4 19 0.79 0 119.68 8.1 100.38 3.64 12.57 25.35 0.00 0.00 25.4 125.7 2.61 39.3 8.5 4
2 SW 4 6 14.00 0 30 1.830 0.85 7.32 30 18.4 22.4 0.79 0 134.69 9.5 113.26 7.3 12.57 52.96 0.00 0.00 78.3 191.6 7.78 56.1 26.0 8
3 SW 4 10 14.00 0 32 1.850 0.87 14.72 35 23.2 30 0.79 0 341.21 13.1 278.31 11.02 12.57 86.53 0.00 0.00 164.9 443.2 12.80 134.9 51.3 12
4 SW 4 14 14.00 0 33 1.860 0.88 18.24 39 26.1 35 0.79 0 475.88 15.5 385.92 16.48 12.57 134.49 0.00 0.00 299.3 685.3 17.81 210.6 87.7 16
5 SW 4 20 14.00 0 34 1.890 0.91 21.88 42 29.4 41 0.79 0 644.15 18.7 520.59 20.06 12.57 170.03 0.00 0.00 469.4 990.0 24.98 305.0 134.5 20
6 SW 5 23 14.00 0 36 1.990 1.01 26.93 50 38.8 56 0.79 0 1044 28.4 841.93 12.645 15.71 144.31 0.00 0.00 613.7 1455.6 26.92 458.3 170.1 25
7 SW 2 25 14.00 0 36 2.000 1.02 28.97 50 38.8 56 0.79 0 1123 28.7 904.23 27.95 6.28 127.59 0.00 0.00 741.3 1645.5 29.06 519.4 202.0 27

Recommendation:
a) Pile Diameter (mm) 1000 1000 1000
b) Pile cut off level (m) 2.00 2.00 2.00
c) Pile length from cut off (m) 20 23 25
d) Pile Shaft Length (m) 20 25 27
d) Vertical Pile Capacity (tonnes) 305.0 458 519
e) Uplift pile capacity (Tonnes) 134.5 170 202

* For Vertical capacity of Pile, weight of the pile has not been considered.
Design of Pile Foundation
Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]

Type of Based on Bore


Name of Project: Soil Investigation Amritsar MNB Location 4+983 A1 Pile Cut-off level (m) 2.30
Structure Hole

Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1200 1 3 (m)
Coefficient Ks Resistance

Liquefaction depth below cut-off level (m) 0

Bearing Ultimate Base Resistance Ultimate Shaft Friction


Capacity Factors Ppu = Ap (cNc + PdNq + 0.5gDNg) PSU = (Ʃ(Ks.Pdi.tand). Asi + a.c.As)
Total/ Total
Angle of g
Submerg Effective Ultimate Total Safe Capacity, Total safe
Type of Thickness Length Water Weight of Pile
Cohesion, Shearing (densit ed Unit overburden Effective Capacity, PS (Tonnes) uplift
Layer no. Sub Soil of Layer from Cut table y of over pile, WP Length
C (t/m2) Resistance Weight Pressure at pile tip PU = Ppu + capacity
Layer (m) off level (W.T.) (m) soil) burden (Tonnes) (m)
, f (deg.) of Soil "qtip" (t/m2) Ap 0.5.g.D.N Ppu Asi (Ks.Pdi.tand).A Adhesion PSU PSU PS = PU/3 - WP (Tonnes)
(t/m3) (t/m3) Nc Nq Ng c.Nc Pd.Nq Pressure at a.c.As
(m2) g (tonnes) (m2) si Factor, a (tonnes) (tonnes)
c.g. of the
layer 'Pdi'
(t/m2)

1 SM 4 2.30 14.00 0 29 1.820 0.84 7.28 28 16.4 19 1.13 0 119.68 9.7 146.38 3.64 15.08 30.43 0.00 0.00 30.4 176.8 4.32 54.6 11.4 4
2 SW 4 6.3 14.00 0 30 1.830 0.85 7.32 30 18.4 22.4 1.13 0 134.69 11.4 165.25 7.3 15.08 63.56 0.00 0.00 94.0 259.2 11.76 74.7 33.7 8
3 SW 4 10.3 14.00 0 32 1.850 0.87 14.72 35 23.2 30 1.13 0 341.21 15.8 403.74 11.02 15.08 103.84 0.00 0.00 197.8 601.6 18.99 181.5 65.1 12
4 SW 4 14.3 14.00 0 33 1.860 0.88 18.24 39 26.1 35 1.13 0 475.88 18.6 559.22 16.48 15.08 161.39 0.00 0.00 359.2 918.4 26.20 279.9 110.0 16
5 SW 4 20 14.00 0 34 1.890 0.91 21.88 42 29.4 41 1.13 0 644.15 22.4 753.87 20.06 15.08 204.04 0.00 0.00 563.2 1317.1 35.96 403.1 167.4 20
6 SW 5 25 14.00 0 36 1.990 1.01 26.93 50 38.8 56 1.13 0 1044 34.1 1218.81 12.645 18.85 173.17 0.00 0.00 736.4 1955.2 42.13 609.6 214.0 25
7 SW 2 27 14.00 0 36 2.000 1.02 28.97 50 38.8 56 1.13 0 1123 34.5 1308.59 27.95 7.54 153.11 0.00 0.00 889.5 2198.1 45.19 687.5 252.8 27

Recommendation:
a) Pile Diameter (mm) 1200 1200 1200
b) Pile cut off level (m) 2.3 2.3 2.3
c) Pile length from cut off (m) 20 25 27
d) Pile Shaft Length (m) 20 25 27
d) Vertical Pile Capacity (tonnes) 403.1 610 688
e) Uplift pile capacity (Tonnes) 167.4 214 253

* For Vertical capacity of Pile, weight of the pile has not been considered.
Design of Pile Foundation
Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]

Type of Based on Bore


Name of Project: Soil Investigation Amritsar MNB Location 4+983 A2 Pile Cut-off level (m) 2.00
Structure Hole

Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1000 1 3 (m)
Coefficient Ks Resistance

Liquefaction depth below cut-off level (m) 0

Bearing Ultimate Base Resistance Ultimate Shaft Friction


Capacity Factors Ppu = Ap (cNc + PdNq + 0.5gDNg) PSU = (Ʃ(Ks.Pdi.tand). Asi + a.c.As)
Total/ Total
Angle of g
Submerg Effective Ultimate Total Safe Capacity, Total safe
Type of Thickness Length Water (densit Effective Weight of Pile
Cohesion, Shearing ed Unit overburden Capacity, PS (Tonnes) uplift
Layer no. Sub Soil of Layer from Cut table pile, WP Length
C (t/m2) Resistance y of Weight Pressure at pile tip over PU = Ppu + capacity
Layer (m) off level (W.T.) (m) soil) burden (Tonnes) (m)
, f (deg.) of Soil "qtip" (t/m2) Ap 0.5.g.D.N Ppu Asi (Ks.Pdi.tand).A Adhesion PSU PSU PS = PU/3 - WP (Tonnes)
(t/m3) Nc Nq Ng c.Nc Pd.Nq Pressure at a.c.As
(t/m3) (m2) g (tonnes) (m2) si Factor, a (tonnes) (tonnes)
c.g. of the
layer 'Pdi'
(t/m2)

1 SM 4 2.00 14.00 0 30 1.820 0.84 30 18.4 22.4 0.79 0 0 9.4 7.39 0 12.57 0.00 0.00 0.00 7.4 2.61 2.6 4
2 SM 4 6 14.00 0 31.6 1.820 0.84 7.28 33 20.6 26 0.79 0 150.19 10.9 126.53 3.64 12.57 28.14 0.00 0.00 28.1 154.7 7.82 43.7 14.4 8
3 SW 4 10 14.00 0 33 1.820 0.84 14.56 39 26.1 35 0.79 0 379.87 14.8 309.96 10.92 12.57 89.11 0.00 0.00 117.3 427.2 13.04 129.4 40.4 12
4 SW 4 14 14.00 0 34 1.820 0.84 17.92 42 29.4 41 0.79 0 527.56 17.2 427.89 16.24 12.57 137.65 0.00 0.00 254.9 682.8 18.25 209.3 77.7 16
5 SW 4 20 14.00 0 35 1.820 0.84 21.28 46 33.3 48 0.79 0 708.62 20.2 572.40 19.6 12.57 172.46 0.00 0.00 427.4 999.8 26.08 307.2 125.8 20
6 SW 5 25 14.00 0 35 1.900 0.92 25.88 46 33.3 48 0.79 0 861.8 22.1 694.21 11.82 15.71 130.01 0.00 0.00 557.4 1251.6 31.02 386.2 161.1 25
7 SW 2 27 14.00 0 36 1.920 0.94 27.76 50 38.8 56 0.79 0 1075.7 26.5 865.64 26.82 6.28 122.43 0.00 0.00 679.8 1545.4 33.08 482.1 191.7 27

Recommendation:
a) Pile Diameter (mm) 1000 1000 1000
b) Pile cut off level (m) 2.00 2.00 2.00
c) Pile length from cut off (m) 20 25 27
d) Pile Shaft Length (m) 20 25 27
d) Vertical Pile Capacity (tonnes) 307.2 386 482
e) Uplift pile capacity (Tonnes) 125.8 161 192

* For Vertical capacity of Pile, weight of the pile has not been considered.
Design of Pile Foundation
Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]

Based on Bore
Name of Project: Soil Investigation Amritsar Type of Structure MNB Location 4+983 A2 Pile Cut-off level (m) 2.30
Hole

Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1200 1 3 (m)
Coefficient Ks Resistance

Liquefaction depth below cut-off level (m) 0

Bearing Ultimate Base Resistance Ultimate Shaft Friction


Capacity Factors Ppu = Ap (cNc + PdNq + 0.5gDNg) PSU = (Ʃ(Ks.Pdi.tand). Asi + a.c.As)
Total/ Total
Angle of Submerg Effective Ultimate Total Safe Capacity, Total safe
Type of Thickness Length Water g Effective Weight of Pile
Cohesion, Shearing ed Unit overburden Capacity, PS (Tonnes) uplift
Layer no. Sub Soil of Layer from Cut table (density of over pile, WP Length
C (t/m2) Resistance Weight Pressure at pile tip PU = Ppu + capacity
Layer (m) off level (W.T.) (m) soil) (t/m3) burden (Tonnes) (m)
, f (deg.) of Soil "qtip" (t/m2) Ap 0.5.g.D.N Ppu Asi (Ks.Pdi.tand).A Adhesion PSU PSU PS = PU/3 - WP (Tonnes)
(t/m3) Nc Nq Ng c.Nc Pd.Nq Pressure at a.c.As
(m2) g (tonnes) (m2) si Factor, a (tonnes) (tonnes)
c.g. of the
layer 'Pdi'
(t/m2)

1 SM 4 2.30 14.00 0 30 1.820 0.84 7.28 30 18.4 22.4 1.13 0 134 11.3 164.26 3.64 15.08 31.69 0.00 0.00 31.7 196.0 4.32 61.0 11.7 4
2 SM 4 6.3 14.00 0 31.6 1.820 0.84 7.28 33 20.6 26 1.13 0 150.19 13.1 184.67 7.28 15.08 67.54 0.00 0.00 99.2 283.9 11.83 82.8 35.0 8
3 SW 4 10.3 14.00 0 33 1.820 0.84 14.56 39 26.1 35 1.13 0 379.87 17.7 449.68 10.92 15.08 106.94 0.00 0.00 206.2 655.8 19.34 199.3 67.4 12
4 SW 4 14.3 14.00 0 34 1.820 0.84 17.92 42 29.4 41 1.13 0 527.56 20.7 620.07 16.24 15.08 165.18 0.00 0.00 371.3 991.4 26.85 303.6 113.5 16
5 SW 4 20 14.00 0 35 1.820 0.84 21.28 46 33.3 48 1.13 0 708.62 24.2 828.81 19.6 15.08 206.95 0.00 0.00 578.3 1407.1 37.55 431.5 172.5 20
6 SW 5 25 14.00 0 35 1.900 0.92 25.88 46 33.3 48 1.13 0 861.8 26.5 1004.66 11.82 18.85 156.01 0.00 0.00 734.3 1739.0 44.67 535.0 216.0 25
7 SW 2 27 14.00 0 36 1.920 0.94 27.76 50 38.8 56 1.13 0 1075.7 31.8 1252.51 26.82 7.54 146.92 0.00 0.00 881.2 2133.7 47.64 663.6 253.3 27

Recommendation:
a) Pile Diameter (mm) 1200 1200 1200
b) Pile cut off level (m) 2.3 2.3 2.3
c) Pile length from cut off (m) 20.0 25.0 27.0
d) Pile Shaft Length (m) 20.0 25.0 27.0
d) Vertical Pile Capacity (tonnes) 431.5 535 664
e) Uplift pile capacity (Tonnes) 172.5 216 253

* For Vertical capacity of Pile, weight of the pile has not been considered.
PILE LOAD CAPACITY FOR PILE FOUNDATION

Pile Diameter Vertical Pile Capacity


Location Pile length (m)
(mm) (T)

20 257
1000 25 362
27 411
22+070 P1
20 320
1200 25 545
27 660

PILE LOAD CAPACITY FOR PILE FOUNDATION


Pile Vertical Pile
Location Pile length (m)
Diameter(mm) Capacity(T)
20 253
1000 25 361
27 410
22+070 P2
20 336
1200 25 472
27 533

PILE LOAD CAPACITY FOR PILE FOUNDATION


Pile Diameter Vertical Pile Capacity
Location Pile length (m)
(mm) (T)
20 253
1000 25 361
27 410
33+120 P1
20 336
1200 25 472
27 533
FOR PILE FOUNDATION
Lateral Capacity
Uplift Pile Capacity
(T)
Free Head(T) Fixed Head(T)
114
174 10 25
200
131
208 13 33
243

FOR PILE FOUNDATION


Uplift Pile Lateral Capacity
Capacity(T) Free Head(T) Fixed Head(T)
107
169 10 25
196
135
210 13 33 `
243

FOR PILE FOUNDATION


Uplift Pile Capacity Lateral Capacity
(T) Free Head(T) Fixed Head(T)
107
169 9 25
196
135
210 11 28
243

You might also like