Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]
Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1000 1 3 (m)
Coefficient Ks Resistance
1 SM 4 2.00 14.00 0 29 1.820 0.84 7.28 28 16.4 19 0.79 0 119.68 8.1 100.38 3.64 12.57 25.35 0.00 0.00 25.4 125.7 2.61 39.3 8.5 4
2 SW 4 6 14.00 0 30 1.830 0.85 7.32 30 18.4 22.4 0.79 0 134.69 9.5 113.26 7.3 12.57 52.96 0.00 0.00 78.3 191.6 7.78 56.1 26.0 8
3 SW 4 10 14.00 0 32 1.850 0.87 14.72 35 23.2 30 0.79 0 341.21 13.1 278.31 11.02 12.57 86.53 0.00 0.00 164.9 443.2 12.80 134.9 51.3 12
4 SW 4 14 14.00 0 33 1.860 0.88 18.24 39 26.1 35 0.79 0 475.88 15.5 385.92 16.48 12.57 134.49 0.00 0.00 299.3 685.3 17.81 210.6 87.7 16
5 SW 4 20 14.00 0 34 1.890 0.91 21.88 42 29.4 41 0.79 0 644.15 18.7 520.59 20.06 12.57 170.03 0.00 0.00 469.4 990.0 24.98 305.0 134.5 20
6 SW 5 23 14.00 0 36 1.990 1.01 26.93 50 38.8 56 0.79 0 1044 28.4 841.93 12.645 15.71 144.31 0.00 0.00 613.7 1455.6 26.92 458.3 170.1 25
7 SW 2 25 14.00 0 36 2.000 1.02 28.97 50 38.8 56 0.79 0 1123 28.7 904.23 27.95 6.28 127.59 0.00 0.00 741.3 1645.5 29.06 519.4 202.0 27
Recommendation:
a) Pile Diameter (mm) 1000 1000 1000
b) Pile cut off level (m) 2.00 2.00 2.00
c) Pile length from cut off (m) 20 23 25
d) Pile Shaft Length (m) 20 25 27
d) Vertical Pile Capacity (tonnes) 305.0 458 519
e) Uplift pile capacity (Tonnes) 134.5 170 202
* For Vertical capacity of Pile, weight of the pile has not been considered.
Design of Pile Foundation
Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]
Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1200 1 3 (m)
Coefficient Ks Resistance
1 SM 4 2.30 14.00 0 29 1.820 0.84 7.28 28 16.4 19 1.13 0 119.68 9.7 146.38 3.64 15.08 30.43 0.00 0.00 30.4 176.8 4.32 54.6 11.4 4
2 SW 4 6.3 14.00 0 30 1.830 0.85 7.32 30 18.4 22.4 1.13 0 134.69 11.4 165.25 7.3 15.08 63.56 0.00 0.00 94.0 259.2 11.76 74.7 33.7 8
3 SW 4 10.3 14.00 0 32 1.850 0.87 14.72 35 23.2 30 1.13 0 341.21 15.8 403.74 11.02 15.08 103.84 0.00 0.00 197.8 601.6 18.99 181.5 65.1 12
4 SW 4 14.3 14.00 0 33 1.860 0.88 18.24 39 26.1 35 1.13 0 475.88 18.6 559.22 16.48 15.08 161.39 0.00 0.00 359.2 918.4 26.20 279.9 110.0 16
5 SW 4 20 14.00 0 34 1.890 0.91 21.88 42 29.4 41 1.13 0 644.15 22.4 753.87 20.06 15.08 204.04 0.00 0.00 563.2 1317.1 35.96 403.1 167.4 20
6 SW 5 25 14.00 0 36 1.990 1.01 26.93 50 38.8 56 1.13 0 1044 34.1 1218.81 12.645 18.85 173.17 0.00 0.00 736.4 1955.2 42.13 609.6 214.0 25
7 SW 2 27 14.00 0 36 2.000 1.02 28.97 50 38.8 56 1.13 0 1123 34.5 1308.59 27.95 7.54 153.11 0.00 0.00 889.5 2198.1 45.19 687.5 252.8 27
Recommendation:
a) Pile Diameter (mm) 1200 1200 1200
b) Pile cut off level (m) 2.3 2.3 2.3
c) Pile length from cut off (m) 20 25 27
d) Pile Shaft Length (m) 20 25 27
d) Vertical Pile Capacity (tonnes) 403.1 610 688
e) Uplift pile capacity (Tonnes) 167.4 214 253
* For Vertical capacity of Pile, weight of the pile has not been considered.
Design of Pile Foundation
Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]
Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1000 1 3 (m)
Coefficient Ks Resistance
1 SM 4 2.00 14.00 0 30 1.820 0.84 30 18.4 22.4 0.79 0 0 9.4 7.39 0 12.57 0.00 0.00 0.00 7.4 2.61 2.6 4
2 SM 4 6 14.00 0 31.6 1.820 0.84 7.28 33 20.6 26 0.79 0 150.19 10.9 126.53 3.64 12.57 28.14 0.00 0.00 28.1 154.7 7.82 43.7 14.4 8
3 SW 4 10 14.00 0 33 1.820 0.84 14.56 39 26.1 35 0.79 0 379.87 14.8 309.96 10.92 12.57 89.11 0.00 0.00 117.3 427.2 13.04 129.4 40.4 12
4 SW 4 14 14.00 0 34 1.820 0.84 17.92 42 29.4 41 0.79 0 527.56 17.2 427.89 16.24 12.57 137.65 0.00 0.00 254.9 682.8 18.25 209.3 77.7 16
5 SW 4 20 14.00 0 35 1.820 0.84 21.28 46 33.3 48 0.79 0 708.62 20.2 572.40 19.6 12.57 172.46 0.00 0.00 427.4 999.8 26.08 307.2 125.8 20
6 SW 5 25 14.00 0 35 1.900 0.92 25.88 46 33.3 48 0.79 0 861.8 22.1 694.21 11.82 15.71 130.01 0.00 0.00 557.4 1251.6 31.02 386.2 161.1 25
7 SW 2 27 14.00 0 36 1.920 0.94 27.76 50 38.8 56 0.79 0 1075.7 26.5 865.64 26.82 6.28 122.43 0.00 0.00 679.8 1545.4 33.08 482.1 191.7 27
Recommendation:
a) Pile Diameter (mm) 1000 1000 1000
b) Pile cut off level (m) 2.00 2.00 2.00
c) Pile length from cut off (m) 20 25 27
d) Pile Shaft Length (m) 20 25 27
d) Vertical Pile Capacity (tonnes) 307.2 386 482
e) Uplift pile capacity (Tonnes) 125.8 161 192
* For Vertical capacity of Pile, weight of the pile has not been considered.
Design of Pile Foundation
Estimation of Safe Vertical Load Carrying Capacity of "Bored Cast in Situ Concrete Pile"
[As per IRC 78 - 2014]
Based on Bore
Name of Project: Soil Investigation Amritsar Type of Structure MNB Location 4+983 A2 Pile Cut-off level (m) 2.30
Hole
Bored Inclination of pile with Factor of Safety for Base River or Stream Bed Level/Ground Water Level considered for
Type of Pile Foundation: 3 14.00 Pile Cap Bottom Level RL (m)
Cast-in- vertical Axis (deg.) Resistance Level (m) calculation (m)
situ
Concrete
Pile
Scour Level below the cut off Level
Earth Pressure Factor of Safety for Shaft 0 Pile Cap Top Level (m) 0.00 Pile Tip Level RL (m)
Pile Diameter (mm): 1200 1 3 (m)
Coefficient Ks Resistance
1 SM 4 2.30 14.00 0 30 1.820 0.84 7.28 30 18.4 22.4 1.13 0 134 11.3 164.26 3.64 15.08 31.69 0.00 0.00 31.7 196.0 4.32 61.0 11.7 4
2 SM 4 6.3 14.00 0 31.6 1.820 0.84 7.28 33 20.6 26 1.13 0 150.19 13.1 184.67 7.28 15.08 67.54 0.00 0.00 99.2 283.9 11.83 82.8 35.0 8
3 SW 4 10.3 14.00 0 33 1.820 0.84 14.56 39 26.1 35 1.13 0 379.87 17.7 449.68 10.92 15.08 106.94 0.00 0.00 206.2 655.8 19.34 199.3 67.4 12
4 SW 4 14.3 14.00 0 34 1.820 0.84 17.92 42 29.4 41 1.13 0 527.56 20.7 620.07 16.24 15.08 165.18 0.00 0.00 371.3 991.4 26.85 303.6 113.5 16
5 SW 4 20 14.00 0 35 1.820 0.84 21.28 46 33.3 48 1.13 0 708.62 24.2 828.81 19.6 15.08 206.95 0.00 0.00 578.3 1407.1 37.55 431.5 172.5 20
6 SW 5 25 14.00 0 35 1.900 0.92 25.88 46 33.3 48 1.13 0 861.8 26.5 1004.66 11.82 18.85 156.01 0.00 0.00 734.3 1739.0 44.67 535.0 216.0 25
7 SW 2 27 14.00 0 36 1.920 0.94 27.76 50 38.8 56 1.13 0 1075.7 31.8 1252.51 26.82 7.54 146.92 0.00 0.00 881.2 2133.7 47.64 663.6 253.3 27
Recommendation:
a) Pile Diameter (mm) 1200 1200 1200
b) Pile cut off level (m) 2.3 2.3 2.3
c) Pile length from cut off (m) 20.0 25.0 27.0
d) Pile Shaft Length (m) 20.0 25.0 27.0
d) Vertical Pile Capacity (tonnes) 431.5 535 664
e) Uplift pile capacity (Tonnes) 172.5 216 253
* For Vertical capacity of Pile, weight of the pile has not been considered.
PILE LOAD CAPACITY FOR PILE FOUNDATION
20 257
1000 25 362
27 411
22+070 P1
20 320
1200 25 545
27 660