“TRS002/10.150,103.210/2011-08-19 14:23:06(1/49) [SEC.NO. 5660 SHIP DESIGN OFFICE ELEC. OUTFITTING DESIGN OEP'T TEL.NO, 3959 SHIP NO. 6092/093 | [ TOTAL( SHEETS WITH COVER wi 37,000 DWT CLASS BULK CARRIER SH NAME 2010, JUL. 07 DATE cHeckep py _Y. 6. KIM / arproveo br _¥:M.CHUN 4 NAME OF DRAWING ORAWN ey =. We cally HYUNDAI fe» MIPO DOCKYARD..LID I ULSAN KOREA ELEC. KEY DISTRIBUTION PLAN SCALE | DRAWING NO. REV.NO. NONE 1A000E001 PINAL CONSOLIDATED E-O1 TRS002/10.150,103.210/2011-08-19 14:23:06(2/49) sHiPpxo: 6092/0983 A PLAN HISTORY WG NO* TAQOOEOO1 oare | nev. | war DESCRIPTION onan focoxen| serRoveo BG, [ont | — [oman racranco Fon APPROVAL fiwcia]mcwoo] vox THONDA WIPO BOGRTARS OO TO Te snp Noe 692/093 8 INDEX (1/4) ow. NO: TAQOOEODI DESCRIPTION PAGE DESCRIPTION a [Ptannastony 6 | GENERATOR & SYNCHRO PANEL ee | Inoex 7-9 [No.2 adoy FEEDER PANEL & | GeNeRAL NOTE 7 | TRANSFORMER FOR 220V FEEDER PANEL = E.C.RUNIT COOLER G-H | CABLE SPECIFICATION = La3P-2 = LG3P-3, 1 [srweou usr = LG3P=4 = LG3P-5 J [tavour oF seo a e880 cesr-8 = P=1 PANEL OH ious ace = PROV. REF, PLANT COMP, CONTROL PANEL 8 | -acc. vc compressor 1 |-nio.1 main c.sw PUMP So snC elon ee =n xc We. ATCA PINE = H.4 ocx ore NO.1 MAIN LO PUMP ae NO.2 CYL.LO BOOSTER PUMP NO. FIRE, BILGE & G.S PUMP. ater NO. E/R VENT. FAN SEWAGE TREATMENT PLANT NO.1 M/E & GIE F.0 SUPPLY PUMP a | Seen ACerS NO.1 ME & GIE F.0 CIRC. PUMP =hO. AUST PUMP EST PEL — NO.4 E/R VENT FAN 5 [or a00 FEEDER PL oti | woa crourSranren PEL | ewisronven ron 2207 PezOER PANEL To | -po2 nan cw pov NO.1 STEERING GEAR ~ NO.2 LT C.F.W PUMP NO.S LT C.F.W PUMP. = NO.2 HT C.F.W PUM: NO.2 COMP. BOILER FEED W. PUMP = NO.2 MAIN L.0 PUMP NO.2 FIRE, BILGE & G/S PUMP loop & MPS = NO. E/A VENT. FAN ~ UFEBOAT DAVIT NO.2 MIE & GIE F.0 SUPPLY PUMP 4 |-G-1 PANEL 11 |-No.2 Me @ Gie £.0 CIRC. PUMP. = NO.1 AUX, BLOWER, NO.2 BALLAST PUMP. NO.1 DECK CRANE ~ F.W BOOSTER PUMP. NO.8 DECK CRANE NO.1 FWD WINDLASS & MOORING WINCH NO.1 AFT MOORING WINCH NO.1 CYL, L.O BOOSTER PUMP ‘COMP, BOILER CONTROL PANEL F.W GENERATOR, HATCH COVER HYD. PUMP = DSU CABINET ~ LG8P-8 TRS002/10.150,103.210/2011-08-19 14:23:06(349) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) TRS002/10,150,103.210/2011-08-19 14:23:06(4/49) sHiP No: 692/093 INDEX (2/4) g ows. No: 1A000E001 DESCRIPTION PAGE DESCRIPTION 12~13] Ac 220v FEEDER PANEL. 18 |Lcse-1 12] FROM No.1 TRANSFORMER FOR 220V FEEDER PANEL FROM NO.2 TRANSFORMER FOR 220V FEEDER PANEL ~ 1 PANEL, = -2 PANEL, ~ P-2 PANEL ~ G-2 PANEL — NAVI DIST. BOARD ~ ENGINE CONTROL CONSOLE ~ 002 ALARM RELAY BOX ~ FIRE DET, & ALARM PANEL 13. |- CEILING UGHT IN Ec. ~ SMOKE DET. CABINET ~ QMS UP CABINET 1 ~ H.F.0 TRANSFER PUMP = M.D.O TRANSFER PUMP ~ LO TRANSFER PUMP 14 | ENPCY GENERATOR PANEL & NO.2 E/R VENT.FAN 15. | ewrcy aaay FEEDER PANEL 15 | - TRANSFORMER FOR ESED 220V FEEDER PANEL ~ NO.2 STEERING GEAR ELEC. WHISTLE RELAY BOX ~ 0G 24V BATTERY CHARGER S/GEAR ROOM SUPPLY FAN ~ EM'CY FIRE PUMP LasP-5 ~ UFE @OAT DAVIT ~ SLUDGE PUMP ~ OILY BILGE PUMP — WIE AIR COOLER CHEM. CLEAN PUMP: ~ OILY BILGE SEPARATOR, 20 Lase-3 16~17] ercy Ac 220V FEEDER PANEL 20 = NO.1 MAIN AIR COMPRESSOR ~ NO.1 DECK SERVICE AIR COMP. NO.2 MAIN AIR. COMPRESSOR = NO.2 DECK SERVICE AIR COMP, 16 | - FROM EM’cy TRANSFORMER FOR 220V FIP E-1 PANEL ~€-2 PANEL = NAVI, LIGHT INDI. PANEL, — NAVI, DISTRIBUTION BOARD ~ ENGINE CONTROL CONSOLE ~ BAIDGE CONTROL CONSOLE ~ 002 ALARM RELAY BOX — FIRE DET, & ALARM PANEL ~ UIGHTING FOR S/GEAR ROOM & E/F ESCAPE TRUNK ~ 002 ROOM EXH, FAN ~ BATTERY CHARGER FOR EM'CY DIG 17_ | - COOLANT HEATER FOR EM'CY DIG ~J/B FOR LIFE BOAT BATTERY CHARGER ~ JB FOR RESCUE BOAT BATTERY CHARGER. ~ LIGHTING FOR EM'CY D/G ROOM ~ UGHTING FOR CO2 ROOM ~ RECEPTACLE FOR EM'CY D/G ROOM & GO2 ROOM — SOUND POWERED TEL. RELAY 8X ~ SMOKE DET. CABINET jai~22 Lase-4 a 2 = NO.1 H.F.0 PURIFIER, NO.1 H.F.0 PURI, SUPPLY PUMP = NO.1 L.O PURIFIER, NO.1 M.L.O PURI, SUPPLY PUMP ~ PURIFIER ROOM &XH.FAN MIE F.0 AUTO FILTER - NO.2H.F.0 PURIFIER NO.2 H.F.0 PURI, SUPPLY PUMP - NO.2L.0 PURIFIER, NO.2 M.L.O PURI, SUPPLY PUMP e3~25} LosP-4 23 G/E M.0.0 FLUSHING PUMP ~ EM'CY AIR COMPRESSOR, = NO.2 GIE L.0 PRIMING PUMP & J.W PRE-HEATER, — NO.8 GIE LO PRIMING PUMP & JW PRE- HEATER THYUNOAT IPO DOCK YARD 6,70, Ae E01 1027) SHIP NO: 6092/093 INDEX (3/4) 9 own TA0OGEOOT DESORIPTION re DESCAPTION oe canerae ee = Gf LOFTS FIN Doar tspama iy nea Taine Sane geo cama sare tenes Saou ae See ramen nes Sanwone See ecw Eee eee nome — WADNG AREA SHH Fan thane = GisereR eae SWE LOAUDARTEA ae eee ie i awe St GALLEY SUPPLY FAN — NO.2 DECK CRANE 220V DIST. BOARD ~ GALLEY EXH. FAN ~ NO.3 DECK CRANE 220V DIST. BOARD: = Sean SPACE EX. FA Bio beck Gwe cn cet eon ~ AHU FAN ~ BALLAST CONTROL CONSOLE Serer Soci Seen See res @ [evra Pozar eArren Grandes T Soon FANE vaste bsrosth wee ae ee Scr TWO. CARGO HOLD EHF Fa TED) taney NO CARGO HOLD ENT FAN FORD Sree eT No.t Gurao HOLD Bx aN TED) oe 7 Nod exneo HOU EH FAN PORT eee enema 7 NO Ganeo HOU EH EAN PORT ees erect ai aera ators no a = NO.1 CARGO HOLD EXH. FAN (ST8O) - WATER BOILER = NO.1 CARGO HOLD EXH. FAN (PORT) COFFEE MACHINE ~ NO.2 CARGO HOLD EXH. FAN (STBD) ~ TOASTER — NO.2 CARGO HOLD EXH. FAN (PORT) HAND IRON ~ PAINT & LAMP STORE EXH. FAN ~ ELECTAIC HEATER — BOGUN SvOnE SUPPLY ean pred tees @ lEenc omic means Bano Sone mee foe ~ DRYING TUMBLER ~ 1-6 LIGHTING PANEL ~ DAVING TUMBLER = RECEP. FOR ARC WELDER ~ ROLLER IRON Stee none ue Fear POR DeoRcOaE OF FLING PN TRS002/10.150,103.210/2011-08-19 14:23:06(6/49) THYUNOAT WIPO DOCK YARD 60,70, Ae E01 1027) TRS002/10.150,103.210/2011-08-19 14:23:06(6/49) sHiP No: 692/093 E INDEX (4/4) Swine” AGOOEODI DESCRIPTION race DESCRIPTION fs-ss) wan, osTmLTION BOARD sve] oc 2a enrTeny cunnGen a DST. BOARD oe |= PORE SUPPLY ONT FOR S-ERNG FRO Ff aaesrieae 7 880 UDA PROCESSOR UT = fe it rom exc 0FG ROOM RECEP. FOR ORY SIGNAL LIGHT No.| ACIDE owen SUPPLY UNT FoR GPS FESR. FOR DAY SGML GAT Peale rd ~ GYRO CONTROL BOX ea es ~ SPEED LOG MULTI DISTRIBUTIOR Ease raallt celles = ECHO SOUNDER PRINTER, ~ ECHO SOUNDER DIST. BOX B AC/DC SI EGHO SOUNDER DIS =n Ao Powe SUPPLY UN “yoo “ister Look As Ttoronoen Unt os | -nasren cock = er sea hubue eooness = Gso0 SonsoLe = pusue noo = yavexaz/o0 Powe SUPPLY UT THEATER ote = FECEPTAGLE ron I TRANSSENER “ALLAST CONTROL OONSOLE eevee auaae! ~ ENGINE CONTRO CONSOLE = fes8-UFom os? er. CHaMeER ~ BNGNE Conrro cons =Cas mun aiPuren = rece. FOR Cuneo SYSTEM ~pusut ones aah fue fn SP NEMORK STS. ps a See FON NETWORK SYS TRS002/10.150,103.210/2011-08-19 14:23:06(7149) y SHIP NO: 692/093 F. for GENERAL NOTE owG. No: TAQOOEQO1 SHIP'S NATIONAL: MALTA, 2, RULE AND REGULATION : ONY HAT “BULK CARRIER ESP, BC-A (HOLD NO.2 & & MAY BE EMPTY}. GRABIZ20] OF, €0. 615. TMON, BWN-E(S), DO-E, HAL) 9. 1He THe MAN {ENTIAL TAPING BREAKERS A {ERATOR WHEN THE OPERATING GENERATOA(S) IS (A ‘50 INSTALLED AS TO BE TAIPPED BY OVER CURRENT RELAYS FOR OVER LOA ‘OY TRIPPING BREAKERS ARE SO INSTALLED AS TO GE TAIPPED BY EM'CY STOP IN THE EVENT OF FIRE, ‘THE EM'CY STOP SWITCHES ARE TO BE LOCATED OUTSIDE OF ENGINE ROOM (E{R ENTRANCE, WH CONSOLE AND FIRE CONTROL STATION] '5, THE CERTIFICATES FOR EXPLOSION PROOF EOUIPMENT TO BE SEPARATELY SUBMITTED ‘THE CERIFIGATE(S) FOR MOTOR (100KW AND ABOVE) TO BE SEPARATELY SUBKITTED. 6. THE STEERING GEAR Ft EF IS TO BE PROVIDED WITH SHORT-CIRCUIT PROTECTION ONLY, WHICH ISTO BE LOCATED AT THE MAIN (OF EMERGENCY SWITCHBOARD, HOWEVER, OVERLOAD PROTECTION MAY BE PERMITTED IFT 1S SET AT A VALUE NOT LESS THAN 200% OF THE FULL LOAD CURRENT OF THE MOTOR (OR OF ALL THE LOADS ON THE FEEDER). AND IS TO BE ARRANGED TO PEAT ‘THE PASSAGE OF THE STARTING CURRENT. THE AIR CIRCUIT BREAKERS cen :ATORS ARE SO INTERLOCKS AS NOT TO OPERATEIN PARALLEL WITH SHORE surpty. 8, THE CABLE HAVING NOMINAL OUTDIAMETER 30MM AND ABOVE ARE NOT TO BE SUNCHED OR LAID TOGETHER IN FLA FORMATION MORE THAN Sik (6) CABLES. THE GABLE HAVING NOMINAL OUTDIAMETER NOT MORE THAN 30MM ARE TO ‘SYMBOL CODE_| 1M: NO.1 «4oV FEEDER PANEL NO.2 440V FEEDER PANE 1Ro-220V FEEDER PANEL ‘CY AC A0V FEEDER PANEL EW'GY AC 220V FEEDEA PANEL $1 :NO.1 GAOUP STARTER PANEL SY: SYNCHRO PANEL US LOCAL GROUP STAR PANEL. P: POWER DIAGRAM L: UGHTING DIAGRAW A: CONTROL & INSTRUMENTATION DIAGRAM N: NAVI WIRELESS & INTER-COMM, DIAGRAM F: FIRE DECT. & GEN. ALARM DIAGRAM THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) HIP NO: 6092/09 G CABLE SPECIFICATION (1 / 2) ow. NO: TAQOOEODI 1, IN GENERAL, ELECTRIC CABLE TO BE OF JIS MARINE CABLE (JIS C 9410, 1999), WHICH HAS BEEN APPROVED BY THE CLASSIFICATION SOCIETY EXCEPT SPECIAL CABLES, 2. CABLES WITHOUT VOLTAGE DESIGNATION DENOTE THE 0.6/1KV GRADE CABLE AND CABLES WITH *L* VOLTAGE DESIGNATION DENOTE THE 250V GRADE CABLE, 8. EXAMPLE OF JIS TYPE CABLE (JIS © 8410. 1999) 3XFA HL- ID PY cM NUMBER OF PARALLEL LINE INDIVIDUAL SHIELD A: FIRE RESISTING. CONDUCTOR SIZE (rnm2} CABLE VOLTAGE GRADE FIRE RESISTANCE (NO MAKR: 0.6/1KV, L250¥) COMMON SHIELD NUMBER OF CORE PVC PROTECTIVE COVER EP RUBBER INSULATION STEEL WIRE BRAIDED VO SHEATH INSULATION [_ SHEATH ARMOUR, PROTECTION COVER, o mepnuapen| Acad | c:steeL wine |v: PVC PROTECTWE 2 [[eouste_[vrve YPVC BRAID COVERING 3 [nee NipoP Te: compen wire| 2 Crewocr BRAID TWISTED, PYG D P ¥ c Y Tey, = ¥ ¢ TPY T P v = = + NOTE : SPECIAL NOTICES MARKED WITH CABLE TYPE MEAN AS FOLLOWS. MC: MAKER SUPPLY CABLE IS: INSTRINSICALLY SAFE TYPE CABLE 4, RG + RADIO GUIDE (RADIO FREQUENCY COXIAL CABLE) 5, STANDARD CABLE LIST : REFER TO NEXT PAGE 6, EXAMPLE OF DOT LINE ‘CABLE DES » ORIBED ON OTHER SYSTEM OR CARRIED OUT BY MANUFACTURER, 2) me meen merm : DEFINITION OF ROOM OR AREA. TRS002/10.150,103.210/2011-08-19 14:23:06(8/49) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) TRS002/10.150,103.210/2011-08-19 14:23:06(8/49) CABLE SPECIFICATION (2/2) iain cure H RATING CURRENT / SYMBOL OF CABLE wG,NO: 1A000E001 ee ee = eet SYMBOL] 4 DEG! TYPE SYMBOL] 4 DESH COLD AREA CABLE (FOR COLD CHAMBER) pera x waoeatoonenes | «ace | 208 ieee iY ee aMGt 1A 13.0] 20c eee —|— 204 14.0 | 206 || * “ MGCG12(CORE)X1.0 m| -[- = [is | 250 SP Eee eee FIRE RESISTING CABLE (OTK) FRE AFSISTING GABLE (2501) sHiP No: 692/093 SYMBOL LIST (1 / 1) ows. No: 1A000E001 DESCRIPTION SYMBOL DESCRIPTION MOTOR STAR Oe peo | ata aMMeTER A RUNNING HOUR METER <3] | +2 maker sureyy mari sa_| | +3-yo: stan-oe1a sranrins ATR °AUTO.TRANSFORMER STARTING EM'CY AC GENERATOR = CAPACITY (KW) ATA: AUTO TRANSFOANER STAATE a CAPACITY (HO) FATING CURRENT |S _|_amcircur oneaken (onaw our 1 PUSH BUTTON Box St: STAAT SP: STOP AN A ciRGUMT eRcAKER (oRAW OUT TY \WITH UNDER VOLTAGE TRIP COIL PUSH BUTTON 60x ST:STARTSP:STOP AL: RUNNING LAMP MOLDED CASE CIRCUIT BREAK: I> ESAS EIA OIL PUMPS & FANS STOPISECTION 1 i ES-A2 EIR OIL PUMPS & FANS STOP(SECTION 2) ES-8: EXCEPT EIROOM FANS STOP ES-C | CINOLD & BOSUN STORE FANS STOP NTH SWITCH (P56, SINGLE TYPE) ES-P: Lash-« STOP E602 EIR FANS STOP RECEPTACLE (\P 44, SINGLE FLUSH TYPE) HCO2: C/HOLD & BOSUN STORE FANS STOP JUNCTION 80x (49/47. IP 58) PIT? PREFERENTIAL TRIP 1 ®|©|@\e@/6) |: |=!) FR] | [8 GiGi) RECEPTACLE FOR W/E TURNING GEAR Mca WiTH UNDER VOLTAGE TRIP COIL JUNCTION BOX o FAN coo wir oven consent pe.aY rosroe 8 | ~28. | oisconnection swircn i BOLTED BUS UNK “TRS002/10.150.103,210/2011-08-19 14:29:06(10149) THYUNOAT WIPO DOCK YARD 60...TO, Ae E01 1027) 092/083 1 A000E001 SHIP N 20S, NO T3NVd UBLUVLS 4NOWO ON TaNWd Y30334 ADP? LON ANVd HOLVYINIO |'ON TaNWd 3lL-sne fr = a TaNYd OHONAS a a a w a T3NVd YOLVUSNID Z'ON 3 @ g TANWd YOLVU3N39 €°ON w °° = ‘TaN 430334 APY Z’ON > oO = s TANYd UBLUVIS dN}OWD Z'ON < TBNYd 430334 A0Ze FRONT { FWD for Ae E01 1027) TaNVd Y30334 A0ZZ AO.W3 ANY Y30IIS ADP AD,S TANVd HOLWHSNSD ADJ FRONT THYUNOAT WIPO DOCK YARD GO,.70, YaLUVIS. Nv IN3A W/3 Z'ON HLIM G3NISINOO T3NWd NOILOZNNOO 3HOHS (riss)e0:ez'nt 61-00-s102/012'e01 081 o1/zo0saL, “TRSO02I10.150.109.210/2011-08-19 14:23:06(12149) MAIN SWITCHBOARD alee eceanore 1 NO.1 GROUP STARTER PANEL (1/2) 2G, NO: 1A000E001 (ECA) sa24 @ ~) No.1 MAIN c.s.w PUMP 8 = wos a8 024 ay 7 ~) Noe MAIN c.s.w PUMP a z roulo aa sua u NL) our ot c.F.w Pune 8 oo a8 ars4 eae) 7 ©) No.1 HT c.F.weume a 5 iy ie 268 ae 2-gs1-5 MD) —_NO.1 COMP. BOILER FEED z : ae se) water Pup 2 2 18 casa Yo P-gS1-6.68 u = ~) No.1 MAIN Lo PUMP : ree 55 wa 2-951-178 ae ra Saree Tet (S) NO.1 FIRE, BILGE & G/S PUMP 2 e-os1-ra EGA 48 2124 “M) NO.1 E/R VENT FAN : TEC 33) (NON-REV.) isa ee p-si-g M }/“L rast %) Nout Mle & Ge F.0 SUP, PUMP f a THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002I10.150.109.210/2011-08-19 14:23:06(19149) MAIN SWITCHBOARD sHeNe es Queers 2 0.1 GROUP STARTER PANEL (2/2) Jows.so 1A000€001 19g aa S44 east-10 ~*~) NO.1 MIE & G/E F.0 CIRC. PUMP : . A a 78 5 Bl ceo pe 1420 5 2 SASSI IA x NO.1 BALLAST PUMP 2 oo 2124 P-GS1-12 M NO.4 E/R VENT FAN - TEAR aaa (REVERSIBLE) TYUNON WIPO DOGKYARD GO.ATO Tee oT eIaRzaT) “TRS002/10.150.103,210/2011-08-19 14:23:06(14/49) MAIN SWITCHBOARD |O.1 440V FEEDER PANEL(1/3) xo: 6092/0893 3 ows. No: 1A000E001 ‘AG 440V, SPH, 6OHZ Pomctaie TESTS 7 soomNst.(600) Pow. - TTetosA) Ce) i Pama TrITSEAD 100/50 Boies, = TTat63 +oo/t00 Poms, TSUTZBAT cose sore ron — JB =e 100/90 Pome TroteTAy 190/40 Poimo. = ‘AG 220V FEEDER PANEL (SEE P.12) NO.1 STEERING GEAR (22kW, 38.38) Lgsp-1 (SEE P18) LesP-3 (SEE P.20) LgsP-4 (SEE P.21) Lasp-5 (SEE P.24) LgsP-9 (SEE P.29) ICOP & MGPS POWER SUPPLY UNIT LIFEBOAT DAVIT CONT. PANEL (1k, 228) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02/10.150.103.210/2011-08-19 14:29:06(15149) MAIN SWITCHBOARD |O.1 440V FEEDER PANEL(2/3) sHP No: 6092/0893 4 WSO: 1AQ00EOO1 ‘AG 440V, SPH, 6OHZ 180 e-m-10 TYTOTSBAT +0100 ie TSIRaAT soo}s0 Ponca 08128 IPTC soyaco pom 90 196 area zasnsa I somes (ey TCT ewcis st ecmtis at pesncar rate emis rat G-1 PANEL (SEE P.32) NO.1 AUX. BLOWER STARTER (37KW, 63.38) NO.1 DECK CRANE NO.8 DECK CRANE NO.1 FWD WINDLASS & MOORING WINCH STARTER (50.1kW, 848) NO.1 AFT MOORING WINCH STARTER (50. 1KW, 844) NO.1 CYL, LO BOOSTER PUMP STARTER (2.2kW) COMP. BOILER CONTROL PANEL F.W GENERATOR CONT. PANEL THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.109.210/2011-08-19 14:23:06(16/49) > MAIN SWITCHBOARD 10.1 440V FEEDER PANEL(3/3) sHP No: 6092/0893 5 ows. No: 1A000E001 asy200 Botne19.19% I YEOTTEEAT = ns 5 fe 100018 E b-1M-20 - TSHTA 2 09/100 ‘song sono pws JIB. say HATCH COVER HYD, PUMP STARTER M/E DSU CABINET LasP-8 (SEE P.28) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSOO2/10.150.103.210/2011-08-19 14:29:06(17149) MAIN SWITCHBOARD ee cores 6 GENERATOR & SYNCHRO PANEL wG.NO: 1A000E001 NO.1 GENERATOR PANEL 50/1 12070) “6 \ _NO.1 GENERATOR rT Bb) xcasov are conz 08 oF ‘0K (G40xI), 10260 ACB FOR NO.1 GENERATOR IS INTERLOCKED WITH SHORE POWER. EoSI- TIA 1810. EMERGENCY SWITCHBOARD NO.2 GENERATOR PANEL 1 2s0/as2t.T0) BRTTOTSERY 150/962(.70) @\ _NO.2 GENERATOR a 50V 99H BOHZ 0.8 F SKA (4040), 8668 ‘AOB FOR NO.2 GENERATOR IS INTERLOCKED WITH SHORE POWER. NO.8 GENERATOR, [AC ASOV 99H 60HZ 0.8 F 79KV (SADA). 58 ACB FOR NO.3 GENERATOR IS INTERLOCKED WITH SHORE POWER. THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.109.210/2011-08-19 14:23:06(18/49) MAIN SWITCHBOARD sHeNe es Queers ie NO.2 440V FEEDER PANEL(1/3) ows. No: 1AQ00E001 noz ta zn 00/4000) aoe 220V FEEDER PANEL csr) (see P12) — * — £.C.R UNIT COOLER poms ugsP-2 Tie * (SEE P.19) Poca usse-3 TOTS (SEE P.20) z Paes ~ Lasr4 = ey Hl ToS (SEE P.22) 3 2 100180 Pome Lasp-5 Tar (SEE P.25) 180 e-ower - Lasr-6 TTTERAT (SEE P.26) zasii2s P-1 PANEL (Se€ P.20) 190190 poms = PROV. REF. PLANT OMPRESSOR TrateAy CONT. PANEL TYONON HPO DOGKYARD GO.ATO: Tee oT eIaRzaT) “TRS002/10.150.103.210/2011-08-19 14:23:06(18149) MAIN SWITCHBOARD NO.2 440V FEEDER PANEL(2/3) xo: 6092/0893 8 ows. No: 1A000E001 ‘AG 440V, SPH, 6OHZ agit ‘AGC. AC COMPRESSOR CONT. ei ‘oo/t00 eo PANEL (63KW. 100.1) NO.2 AUX. BLOWER STARTER 2 4oqg00 TestGaA) (a7KW, 63.38) > — NO.2 DECK CRANE (=) -son/g00 rT VTOCTEERT P-2-13,198,190 = — NO.4 DECK CRANE NO.2 FWD WINDLASS & Ap 22pf150 ar HaYTOT TERA 225150 TYSSLTESAT * MOORING WINCH STARTER, (50.1kW, B44) NO.2 AFT MOORING WINCH i, STARTER (50.1KW. 844) (E TEEOAT STARTER (2.2KW) oo “TRSO02/10.150.103,210/2011-08-19 14:23:06(20149) > MAIN SWITCHBOARD NO.2 440V FEEDER PANEL(3/3) sHP No: 6092/0893 9 ows. No: 1A000E001 AG 440V, SPH, 6ONZ 109/90 e-2M-20 225/150 PUMP STARTER FOR L.FF.S (7.5 KW, 14,78) TEST PANEL Lasp-7 (SEE P.27) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02/10.150.109,210/2011-08-19 14:23:06(21/49) MAIN SWITCHBOARD NO.2 GROUP STARTER PANEL (1/2) 2G, NO: 1A000E001 sHiP No: 692/093 10, wos a case at ©) NO.2 MAN 6.8.4 PUMP A z roo a sue 7 ©) oz itcew Pune i 3 ions 8 sue wt ©) os urerw Pune A z ae a8 « i dose : Son 2) voz orw euMe e B) uso aw se ey ae HS) No.2 come. BOILER FEED e | “a a) water PUMP 2 ‘a sae 9 . i sagen 2 ro XY) noe wan 1.0 PUMP | 3 - Stat - (E) woz mre, ace & o/s rune > egse70 ata ts aie ce NO,3 E/R VENT FAN | Si) (soNsREV) vasa se — iy “ot roe ) NO.2 M/E & G/E F.0 SUPP. PUMP . : THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02/10.150.103,210/2011-08-19 14:29:06(22149) NO.2 GROUP STARTER PANEL (2/2) ows.no: 1a000E001 MAIN SWITCHBOARD snip no 6092/0983 i AG 440V, SPH, 6ONZ 7 i . aoe ® 0.2 BALLAST PUMP 2 oe 7 a sg. ©) pw ecosten pw ~- x THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002/10.150.103.210/2011-08-19 14:23:06(23149) MAIN SWITCHBOARD 220V FEEDER PANEL (1/2) sup No: 692/093 12 WSO: 1AQ00EOO1 220V FEEDER PANEL Fat z= B] sono 2 ae 5 B NO.1 MAIN TRANSFORMER (SEE P.3) NO.2 MAIN TRANSFORMER, (SEE P.7), L+t PANEL L+2 PANEL P+2 PANEL. (See P.31) G-2 PANEL (SEE P.33) NAVI. DISTRIBUTION BOARD (SEE P.35) ENGINE CONTROL CONSOLE (O2 ALARM RELAY BOX FIRE DET. & ALARM PANEL THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.103.210/2011-08-19 14:29:06(24/49) > MAIN SWITCHBOARD 220V FEEDER PANEL (2/2) sHP No: 6092/0893 13, ows. No: 1A000E001 AG 2200, SPH, 6ONZ ons 2p pait9 = TER nits ons CEILING LIGHT IN €.0.R ‘SMOKE DET. CABINET BMS UP CABINET 1 THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002/10.150.109.210/2011-08-19 14:23:06(25149) EM’CY SWITCHBOARD. ae EM’CY GENERATOR PANEL ows. No: 1A000E001 xo: 6092/0893 14 CONNECTION PANEL) voy uz am scey-00 OY) No.2 E/A VENT FAN fe atte Sy) eversieve) INTERLOCKING wit EM'CY GENERATOR s0o/gt.10) ‘SHORE POWER (600A) M.C.C.8 FOR SHORE POWER IS INTERLOCKED WITH EM'CY GENERATOR, NO.1,2 AND 8 MAIN GENERATOR, MSBD SYNCHRO PANEL EM'CY GENERATOR uK [AC ABDV 2PH 6OHZ 0.8 PF "SOKVA (120KW), 190.78 AGB FOR EM'CY GENERATOR IS INTERLOCKED WITH SHORE POWER ‘AND BUS-TIE BREAKER. THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02/10.150.103.210/2011-08-19 14:23:06(26149) EM’CY SWITCHBOARD. No: 6092/0993 15, EM’CY 440V FEEDER PANEL (1/1) ows. No: 1A000E001 cia Pe sons (0 “eaovizan poewer an) oet, ESBD 220V FEEDER PANEL Tre THT (SEE P.16) sont (600) PeM2 ~ _NO.2 STEERING GEAR Tata (22KW, 38.38) ‘00/20 Poems ELEO. WHISTLE RELAY BOX THOT? ~ (5.5KW) Pew Sat DC 24y BATTERY CHARGER 8 cn cea noe cas = I pews suusn _(M 5 = oan Stites _(~) _ s/GEAR ROOM SUPPLY FAN = ¢ il mr . os 2 2 00/190 sr1a ee |[Y || cewcnse (i Frzseaa 7], [[eavraara 4 Sy) EM'CY FIRE PUMP 190160 poewer ~ LGSP-5 THe SEE (P.23) 10040 Pee LIFE BOAT DAVIT CONTROL THAR PANEL (11KW. 224) TYUNON’ MIPO DOGK YARD CO. TET IORZET) “TRS002/10.150.103,210/2011-08-19 14:23:06(27149) EM’CY SWITCHBOARD. i EM’CY 220V FEEDER PANEL (1/2) OWS, NO No 092/083 16, 1 A000E001 AG 2200, SPH, 6ONZ 0/30 nis era 7 - El 2 FIYTBLeaA 0s NAVI, LIGHT INDI, PANEL 0/80 NAVI. DISTRIBUTION BOARD (SEE P.35) euiso = ENGINE CONTROL CONSOLE 0/60 * BRIDGE CONTROL CONSOLE sos — = — CO2 ALARM RELAY BOX sols — FIRE DET. & ALARM PANEL sols ze LIGHTING FOR S/GEAR ROOM & E/R ESCAPE TRUNK 20 pe.-10 Me Se sy.) 002 ROOM EXH, FAN soils Pein BATTERY CHARGER FOR Daa EM'CY 0/G. EM’CY TRANSFORMER (SEE P.15) PANEL PANEL THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002/10.150.103.210/2011-08-19 14:23:06(28/49) EM’CY SWITCHBOARD. sup No: 692/093 17, EM’CY 220V FEEDER PANEL (2/2) WSO: 1AQ00EOO1 ‘AG 220V, SPH, 6OHZ sols Ap Preiss x [HS 4} ar [33 P bel PoEL=194 ¢ FOVEzAA sons aeaRT : 2) eee), se sons 2p 15 THEA sous 2 p-eu-16 COOLANT HEATER FOR EM'CY 0/4. JUNCTION BOX FOR LIFE BOAT BATTERY CHARGER JUNCTION BOX FOR RESCUE BOAT BATTERY CHARGER LIGHTING FOR EM'CY D/G ROOM LIGHTING FOR COZ ROOM RECEPTACLES FOR EM'CY D/G ROOM SOUND POWERED TEL. RELAY 80x ‘SMOKE DET. CABINET THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002/10.150.103.210/2011-08-19 14:23:06(29149) LGSP-1 (1/1) xo: 6092/0893 18 ows. No: 1A000E001 ( FLOOR-0k FORT ke Betsict ™ Fy : cr - S] ams san Q pausing we : tar os cans sa paisica we : raat a TST ist Sh FROM NO.1 440V FEEDER PANEL (SEE P.3) H.F.O TRANSFER PUMP M.D.0 TRANSFER PUMP LO TRANSFER PUMP THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002/10.150.103.210/2011-08-19 14:23:06(90149) LGSP-2 (1/1) xo: 6092/0893 19 ows. No: 1A000E001 (© FLo0R-oK st 0) oN paisp-t ow ria = B] sons 4a Ez sz-2 am S tit x = 3S 2 sans am eases . tit a sais 3 3,0 NO.1.2 MAN LO PUMP FROM NO.2 440V FEEDER PANEL (SEE P.7) SLUDGE PUMP OILY BILGE PUMP M/E AIR COOLER CHEM. CLEAN PUMP OILY BILGE SEPARATOR CONTROL PANEL THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSOO2/10.150.103.210/2011-08-19 14:23:06(81/49) LGSP-3 (1/1) sup No: 692/093 20, WSO: 1AQ00EOO1 (L:9R0 0 STD) AC 440V, SPH, 6ORZ ‘AC 440V, SPH, 6OHZ en etsa-1 +og/100 1007s a 4 too/100 wea ; e1so-3 iM « ee ~) No.2 MAIN alR COMPRESSOR = FROM NO.1 440V FEEDER PANEL (SEE P.3) NO.1 DECK SERVICE AIR COMP. STARTER (37KW, 68A) FROM NO.2 440V FEEDER PANEL (SEE P.7) NO.2 DECK SERVICE AIR COMP. STARTER (37KW, 68A) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.109.210/2011-08-19 14:23:06(82/49) sHP No: 6092/0893 24 LGSP-4 (1/2) WSO: 1AQ00EOO1 rai Eee 60/20 a 0.28 ® : a 2 p-isee M : sata x p-is4-5 mo (Fz 2 THCTaAT 2.53 FROM NO.1 440V FEEDER PANEL (SEE P.3) NO.1 H.F.O PURIFIER, NO.1 H.F.O PURI. SUPPLY PUMP NO.1 L.O PURIFIER NO.1 M.L.O PURI. SUPPLY PUMP PURIFIER ROOM EXH. FAN M/E F.O AUTO FILTER, THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.109.210/2011-08-19 14:23:06(89149) LGSP-4 (2/2) xo: 6092/0893 20 ows. No: 1A000E001 p-ise-7 oe = sons 38a 5 rial : e @ i aa S P-ist-10 om i iat < a ,, M010 FLUSHING PUMP FROM NO.2 440V FEEDER PANEL (SEE P.7) NO.2 H.F.0 PURIFIER, NO.2 H.F.0 PURI. SUPPLY PUMP NO.2 L.O PURIFIER NO.2 M.L.O PURI. SUPPLY PUMP THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02/10.150.103.210/2011-08-19 14:23:06(24/49) LGSP-5 (1/3) sup No: 692/093 23, WSO: 1AQ00EOO1 (L2ND DECK STBD) 2-135—1 M 8 A . 5 a x iS 3 @ A TORETAT = FROM EM'CY 440V FEEDER PANEL. (SEE P.15) G/E M.0.0 FLUSHING PUMP EM'CY AIR COMPRESSOR NO.2 G/E LO PRIMING PUMP & JAW PRE-HEATER, NO.3 G/E L.O PRIMING PUMP & JAW PRE-HEATER, THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02/10.150.109,210/2011-08-19 14:29:06(85149) LGSP-5 (2/3) xo: 6092/0893 24, ows. No: 1A000E001 ‘AG 440V, SPH, 6OHZ sonis om Ey pots6o6 ow (fey that s a ; aie = corse ‘ Sten sovge sous siss-10 . FROM NO.1 440V FEEDER PANEL (SEE P.3) NO.1 FLW HYD, PUMP CYL. LO SHIFTING PUMP NO.1 G/E LO PRIMING PUMP & JAW PRE-HEATER, NO.2 GIE L.O PRIMING PUMP & JAW PRE-HEATER, HYD, POWER UNIT FOR V.R.C.S THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) sup No: 692/093 25, WSO: 1AQ00EOO1 LGSP-5 (3/3) FROM NO.2 440V FEEDER PANEL (SEE P.7) sonts a T\ sst M he te ~) No.2 Fw iyo. PUMP suis as ot ~\.) WELDING AREA EXH. FAN a= : ra ns 3 5 cous eausse12 E ae E/R CRANE 7 7 2 2 oR * HEATER FOR CALOAIFIER rh HOT WATER CIRC. PUMP sos * so PALS5-15 BLS516A, - “ “i (~) we TuAWING Gear cous M/E L.O AUTO FILTER “TRSO02/10.150.109.210/2011-08-19 14:23:06(96/49) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.103,210/2011-08-19 14:23:06(87149) LGSP-6 (1/1) sup No: 692/093 26, WSO: 1AQ00EOO1 (AIR COND. ROOM) sons ea eS - raat is sons sea L\ poise-e ” Ey : Tita = sons en oiss-9 ue ey Le vith : ork sea p-s6-4 om ey : rm 7 y| EN 5 z z corso 2 soso [ ois6-6 . fo) att corso 1 Sen sorzo sovzo TwarAT FROM NO.2 440V FEEDER PANEL (SEE P.7) GALLEY SUPPLY FAN GALLEY EXH. FAN SANITARY SPACE EXH, FAN AHU FAN FAN COIL UNIT PROVISION CRANE CONTROL PANEL (15KW. 27.28) RESQUE BOAT DAVIT CONTROL PANEL PROV. REF. PLANT FAN SWBD DC 24V BATTERY CHARGER, (SEE P.37) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.109.210/2011-08-19 14:23:06(98/49) sn No? 692/093 27 AN L@sP-7 (1/1) wwe no) TAQDOEOO1 (Lan cov. n00M9 FROM NO.2 440V FEEDER PANEL (SEE P.9) ey est “) NO.3 CARGO HOLO EXH, FAN : Tata ¥) (Tap) ey pnis7-2 CM) NO.3 CARGO HOLD EXH. FAN : ok ~) teen Ey potst-3 TH) NO.4 CARGO HOLD EXH. FAN 7 : Fatt \) (st80) 2 otsrme “MY, No.4 CARGO HOLD EXH. FAN : —— ¥) oan esr-s “) _NO.5 CARGO HOLD EXH. FAN : eal \) (st80) p-ts7-6 M NO.5 CARGO HOLD EXH. FAN : = &) ian “TRSO02/10.150.109.210/2011-08-19 14:23:06(99149) LGSP-8 (1/1) sup No: 692/093 28, WSO: 1AQ00EOO1 (U80SUN STORE} wm A Ea 8-1 ” reat y ou aa rata . fe eu/an a 21a ES aaa e-is8-3 am 7 that : iz oe an poisece ow rat . sous as sais8-s a ita eo sans ee east mw stat x FROM NO.1 440V FEEDER PANEL (SEE P.5) NO.1 CARGO HOLD EXH. FAN (sTBD) NO.1 CARGO HOLD EXH. FAN (Port) NO.2 CARGO HOLD EXH. FAN (sTeo) NO.2 CARGO HOLD EXH. FAN (PORT) PAINT & LAMP STORE XH. FAN BOSUN STORE SUPPLY FAN THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02I10.150.103.210/2011-08-19 14:29:06(40149) xo: 6092/0893 29, ows. No: 1A000E001 LGSP-9 (1/1) (U80SUN STORE} sagan FROM NO.1 440V FEEDER PANEL (SEE P.3) 20KVA SPH SET 0 ‘250 (alfa) 8 UGHTING Panet s 0/60 E T\ @ _EOEPTAGLE FOR ARC WELDER 3 é Q nes RECEPTACLE FOR HATCH COVER ahs Pontast PUMP UNIT a |. _EGEPTACLE FOR DECK ORANE —— OIC ELLING PUMP “TRS002I10.150.103,210/2011-08-19 14:29:06(41/49) P-1 PANEL (1/1) sup No: 692/093 30, WSO: 1AQ00EOO1 (L: WORKSHOP) ‘AG 440V, SPH, 6OHZ snus uns pois fit ous sore print air @) soy FROM NO.2 440V FEEDER PANEL (SEE P. 7) LATHE GRINDING MACHINE (0.75KW) DRILLING MACHINE (0.75KW) RECEPTACLE FOR ARC WELDER WORKISHOP UNIT COOLER THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRSO02/10.150.103.210/2011-08-19 14:29:06(42/49) P-2 PANEL (1/1) sHP No: 6092/0893 31 WSO: 1AQ00EOO1 ‘AO 220V, SPH, 6OHZ {eB-DEOK CABLE TAUNIO FROM 220V FEEDER PANEL (SEE P. 12) aso faite = LB PANEL savso e-p2-2 Fife L-4 PANEL oven afte = LS PANEL aveo e-po- ipo BRIDGE CONTROL CONSOLE saxo e705 - _NO.2 DECK CRANE 220v THTOCTAT DIST. BOARD saiz0 o-p0-6 = NOS DECK CRANE 220v Tran DIST. BOARD 20 spar NO.4 DECK CRANE 220V Far DIST. BOARD sovz0 = BALLAST CONTROL CONSOLE THYUNOAT MPO DOCK YARD CO. 7 Ae E01 1027) “TRSO02/10.150.103.210/2011-08-19 14:29:06(43149) G-1 & G-2 PANEL (1/2) sup No: 692/093 32, WSO: 1AQ00EOO1 (GALLEY) coven TYTETER? a sorts * e012 waar . sous coits » ze = 8 sous + Pogt-5 2 a - sons enai-e : Tee sors e-o1-7 Ta TYSSTIOZAT fe FROM NO.1 440V FEEDER PANEL (SEE P.4) COOKING RANGE (20KW) WASTE DISPOSER DISH WASHER, (.65KW) UNIVERSAL MIXER, (0.75KW) FRYING FAN (6.9KW) BAKING OVEN (Kw) DEEP FAT FRYER (72K) G-3 PANEL, (SEE P.34) THYUNOAT MPO DOCK YARD CO. Ae E01 1027) “TRSO02I10.150.109.210/2011-08-19 14:29:06(44/49) G-1 & G-2 PANEL (2/2) sup No: 692/093 33, WSO: 1AQ00EOO1 AC 220V, SPH, 6OHZ sos TRRZEOAT sons p-go-2 PREOAT sos sols sos p-a2-6 oar sols oF SP fe 8 re GALLEY SUPPLY FAN & GALLEY Ext, FAN FAN GOIL UNIT MAIN 200V FEEDER PANEL (SEE P.12) MEAT SLICER (0.97KW) POTATO PEELER (0.74KW) asain REFRIGERATOR (0.55KW) WATER BOILER (3.2KW) (COFFEE MACHINE (2.25KW) TOASTER (1.9KW) HAND IRON (1.7KW) ELECTRIC HEATER (2KW) ANSUL BOX FOR DEEP FAT FRYER, oan THYUNOAT MPO DOCK YARD CO. Ae E01 1027) “TRS002/10.150.103.210/2011-08-19 14:23:06(45149) G-3 PANEL (1/1) sHP No: 6092/0893 34, WSO: 1AQ00EOO1 AC 220V, SPH, 6OHZ e0iz0 TYACTAT ens ans ons ants p-63-5 TretaOAT ans TYEDEAT ens G-1 PANEL (SEE P.32) WASHER EXTRACTOR (7.8KW) WASHER EXTRACTOR (6.0KW) WASHER EXTRACTOR (6.0KW) WASHER EXTRACTOR (6.0KW) DRYING TUMBLER (5KW) (Hs AMOR DRYING TUMBLER (5KW) ROLLER IRON (SKW) THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002/10.150.103.210/2011-08-19 14:23:06(46/49) NAVI. DISTRIBUTION BOARD (1/2) sup No: 692/093 35, WSO: 1AQ00EOO1 (GWHEEL HOUSE) JAUTO CHANGE OVER UNIT snus sols 2p NonD-2 Tea N-no-3 TORT sols op ys Daa ie sons = 2e cNo=§ IS aR io 2 sols sos 2p sols ze 0-8 aeaRt sos op sons ze N-No-10, a soils op 220V FEEDER PANEL (SEE P.12) EM'CY 220V FEEDER PANEL. (SEE P.16) POWER SUPPLY UNIT FOR ‘S-BAND RADAR, S-BAND RADAR PROCESSOR UNIT| NO.1 ECOIS UPS NO.1 AC/DC POWER SUPPLY UNIT FOR DGPS: GYRO CONTROL BOX (COURSE RECORDER SPEED LOG DISTRIBUTOR ECHO SOUNDER DIST. BOX \VDR POWER SUPPLY UNIT AIS UPS SIGNAL LIGHT INDICATING PANEL, THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) “TRS002/10.150.103,210/2011-08-19 14:29:06(47149) NAVI. DISTRIBUTION BOARD (2/2) sup No: 692/093 36, WSO: 1AQ00EOO1 ‘AG 2200, SPH, 6OHZ sols oe NcNo-21 Tet2eHT euiso Tate sols ze soils say sols = aaa sols 2p sols TaaeaT sols op sons aa soils 2p ATOR MASTER CLOCK GMDSS CONSOLE NAVITEX AC/DC POWER SUPPLY UNIT RECEPTOLE FOR VHF TRANCEIVER| AUTO TEL. EXCHANGER M-JB-U FOR HOSP. & REF, CHAMBER CAS MULTI AMPLIFIER RECEP. FOR CHARTCO SYSTEM PUBLIC ADDRESS MAIN UNIT HUB FOR SHIP NETWORK SYS. UPS & SERVER FOR SHIP NETWORK SYS. THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) SPEED LOG.PROGESSORW Whe cose “TRSO02/10.150.109.210/2011-08-19 14:23:06(48/49) sup No: 692/093 37, BATTERY CHARGER & DC 24V DIST. BOARD (1/2) WSO: 1AQ00EOO1 (U:€LEC.EQUIP.A00M) GER @ATTERY CHARG FROM LGSP-6 (SEE P.26) FROM EM'CY 440V FEEDER PANEL (SEE P.15) BATTERY 2av, 300AH Do aay FROM €-2 PANEL TRANSIENT LIGHT FOR W/H ‘TRANSIENT LIGHT FOR EM'CY D/G ROOM RECEP, FOR DAY SIGNAL LIGHT NAVIGATION LIGHT INDICATING PANEL GYRO CONTROL BOX SPEED LOG MULTI DISTRIBUTION ECHO SOUNDER PRINTER AIS AC/DC POWER SUPPLY UNIT MASTER CLOCK ‘SAS TRANSPONDER UNIT AUTO TEL. EXCHANGER THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027) 1423:06(49149) 3 2 BATTERY CHARGER & SHIP NO 092/083 38, DC 24V DIST. BOARD (1/2) 20S, NO 1 A000E001 DC av N-co-14 PS i N-co-16 P87} i PUBLIC ADDRESS WEATHER FAX BRIDGE CONTROL CONSOLE BALLAST CONTROL CONSOLE ENGINE CONTROL CONSOLE ENWAS TERMINAL UNIT THYUNOAT WIPO DOCK YARD GO,.70, Ae E01 1027)

You might also like