Edid041521 (FTKC15-35PVM4)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 92

EDID041521

Split Type Air Conditioners


- Cooling Only -

FTKC-P Series
EDID041521

Split Type
Air Conditioners
FTKC-P Series
FTKC15PVM4 RKC15PVM4
FTKC20PVM4 RKC20PVM4
Cooling Only
FTKC25PVM4 RKC25PVM4
FTKC35PVM4 RKC35PVM4
1. Power Supply ..........................................................................................2
2. Functions.................................................................................................3
3. Specifications ..........................................................................................4
4. Dimensions .............................................................................................6
4.1 Indoor Unit................................................................................................6
4.2 Outdoor Unit .............................................................................................6
5. Wiring Diagrams......................................................................................7
5.1 Indoor Unit................................................................................................7
5.2 Outdoor Unit .............................................................................................7
6. Piping Diagrams......................................................................................8
6.1 Indoor Unit................................................................................................8
6.2 Outdoor Unit .............................................................................................9
7. Capacity Tables ....................................................................................10
7.1 Cooling Only...........................................................................................10
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ............................................................................................12
8. Operation Limit......................................................................................13
9. Sound Level ..........................................................................................14
9.1 Measuring Location ................................................................................14
9.2 Indoor Unit..............................................................................................14
9.3 Outdoor Unit ...........................................................................................15
10.Electric Characteristics..........................................................................16
11.Installation Manual ................................................................................17
11.1 English....................................................................................................17
11.2 Indonesian..............................................................................................27
12.Operation Manual..................................................................................37
12.1 English....................................................................................................37
12.2 Indonesian..............................................................................................61
13.Optional Accessories ............................................................................85
13.1 Option List ..............................................................................................85
13.2 <KPW937B4> Air Direction Adjustment Grille........................................86

Split Type Air Conditioners FTKC-P Series 1


Power Supply EDID041521

1. Power Supply
Indoor Unit Outdoor Unit Power Supply
FTKC15PVM4 RKC15PVM4
FTKC20PVM4 RKC20PVM4 1 phase, 220 - 230 - 240 V, 50 Hz
FTKC25PVM4 RKC25PVM4 1 phase, 220 - 230 V, 60 Hz
FTKC35PVM4 RKC35PVM4

Note: Power Supply Intake ; Outdoor Unit

2 Split Type Air Conditioners FTKC-P Series


EDID041521 Functions

2. Functions

FTKC15/20/25/35PVM4

FTKC15/20/25/35PVM4
RKC15/20/25/35PVM4

RKC15/20/25/35PVM4
Category Functions Category Functions

Basic Inverter (with inverter power control) z Health & Air-purifying filter —
Function Clean
Operation limit for cooling (°CDB) 19.4 Photocatalytic deodorising filter —
~ 46
Air-purifying filter with photocatalytic deodorising —
Operation limit for heating (°CWB) — function
PAM control z Titanium apatite photocatalytic
air-purifying filter z
Standby electricity saving —
Compressor Oval scroll compressor — Air filter (prefilter) z
Swing compressor z Wipe-clean flat panel z
Rotary compressor — Washable grille —
Reluctance DC motor z MOULD PROOF operation —
Comfortable Power-airflow flap z Heating dry operation —
Airflow
Power-airflow dual flaps — Good-sleep cooling operation —
Power-airflow diffuser — Timer WEEKLY TIMER operation —
Wide-angle louvres z 24-hour ON/OFF TIMER z
Auto-swing (up and down) z NIGHT SET mode z
Auto-swing (right and left) — Worry Free Auto-restart (after power failure) z
(Reliability &
3-D airflow — Durability) Self-diagnosis (R/C, LED) z
COMFORT AIRFLOW operation z Wiring error check function —
Comfort Auto fan speed z Anti-corrosion treatment of outdoor heat
Control z
Indoor unit quiet operation z exchanger
NIGHT QUIET mode (automatic) — Flexibility Multi-split / split type compatible indoor unit —
OUTDOOR UNIT QUIET operation (manual) — Flexible power supply correspondence z
INTELLIGENT EYE operation — Chargeless 10 m
Quick warming function — Either side drain (right or left) z
Hot-start function — Power selection —
Automatic defrosting — Remote 5-room centralised controller (option) —
Control
Operation Automatic operation — Remote control adaptor (normal open pulse
contact) (option) —
Programme dry operation z
Fan only z Remote control adaptor —
(normal open contact) (option)
Lifestyle New POWERFUL operation —
Convenience (non-inverter) DIII-NET compatible (adaptor) (option) —
Inverter POWERFUL operation z Remote Wireless z
Controller
Priority-room setting — Wired —
COOL / HEAT mode lock —
HOME LEAVE operation —
LOW WATT operation z
Indoor unit ON/OFF button z
Signal receiving sign z
R/C with back light —
Temperature display —
Note: z : Available
— : Not available

Split Type Air Conditioners FTKC-P Series 3


Specifications EDID041521

3. Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Indoor Unit FTKC15PVM4 FTKC20PVM4
Model
Outdoor Unit RKC15PVM4 RKC20PVM4
kW 1.5 (0.75 ~ 1.9) 2.0 (1.0 ~ 2.4)
Capacity Btu/h 5,100 (2,500 ~ 6,500) 6,800 (3,400 ~ 8,200)
Rated (Min. ~ Max.)
kcal/h 1,290 (650 ~ 1,630) 1,720 (860 ~ 2,060)
Moisture Removal L/h 1.2 1.2
Running Current (Rated) A 2.2 2.6
Power Consumption (Rated) W 337 500
Power Factor (Rated) % 69.6 87.4
COP (Rated) W/W 4.45 4.00
Liquid mm φ 6.4 φ 6.4
Piping φ 9.5 φ 9.5
Connections Gas mm
Drain mm φ 16.0 φ 16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 15 15
Max. Interunit Height Difference m 12 12
Chargeless m 10 10
Amount of Additional Charge of g/m 20 20
Refrigerant
Indoor Unit FTKC15PVM4 FTKC20PVM4
Front Panel Colour Shiny Pure White Shiny Pure White
H 9.0 (318) 9.0 (318)
M m³/min 6.7 (237) 6.7 (237)
Airflow Rate (cfm)
L 4.4 (155) 4.4 (155)
SL 3.5 (124) 3.5 (124)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.19 0.19
Power Consumption (Rated) W 39 39
Power Factor (Rated) % 93.3 93.3
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 283 × 770 × 203 283 × 770 × 203
Packaged Dimensions (H × W × D) mm 263 × 840 × 344 263 × 840 × 344
Weight (Mass) kg 8 8
Gross Weight (Gross Mass) kg 10 10
Sound
Pressure H / M / L / SL dB(A) 38 / 33 / 25 / 22 38 / 33 / 25 / 22
Level
Outdoor Unit RKC15PVM4 RKC20PVM4
Casing Colour Ivory White Ivory White
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 1YC15AXD 1YC15AXD
Motor Output W 278 441
Refrigerant Type FW68DA FW68DA
Oil Charge L 0.23 0.23
Type R-32 R-32
Refrigerant
Charge kg 0.5 0.5
Airflow Rate H m³/min 27.1 (957) 27.1 (957)
(cfm)
Type Propeller Propeller
Fan
Motor Output W 20 20
Running Current (Rated) A 2.01 2.41
Power Consumption (Rated) W 298 461
Power Factor (Rated) % 67.4 86.9
Starting Current A 2.06 2.06
Dimensions (H × W × D) mm 550 × 658 × 275 550 × 658 × 275
Packaged Dimensions (H × W × D) mm 616 × 788 × 359 616 × 788 × 359
Weight (Mass) kg 23 23
Gross Weight (Gross Mass) kg 26 26
Sound
Pressure H dB(A) 46 - 47 - 47 / 48 - 49 46 - 47 - 47 / 48 - 49
Level
Drawing No. 3D094191C 3D094192C

Note: „ The data are based on the conditions shown in the table below.
Cooling Piping Length Conversion Formulae

Indoor ; 27°CDB / 19°CWB kcal/h = kW × 860


Outdoor ; 35°CDB / 24°CWB 7.5 m Btu/h = kW × 3412
cfm = m³/min × 35.3

4 Split Type Air Conditioners FTKC-P Series


EDID041521 Specifications

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Indoor Unit FTKC25PVM4 FTKC35PVM4
Model
Outdoor Unit RKC25PVM4 RKC35PVM4
kW 2.5 (1.0 ~ 3.4) 3.5 (1.3 ~ 4.1)
Capacity Btu/h 8,500 (3,400 ~ 11,600) 11,900 (4,400 ~ 14,000)
Rated (Min. ~ Max.)
kcal/h 2,150 (860 ~ 2,920) 3,010 (1,120 ~ 3,530)
Moisture Removal L/h 1.2 1.9
Running Current (Rated) A 3.3 4.5
Power Consumption (Rated) W 700 990
Power Factor (Rated) % 96.4 99.1
COP (Rated) W/W 3.57 3.54
Liquid mm φ 6.4 φ 6.4
Piping φ 9.5 φ 9.5
Connections Gas mm
Drain mm φ 16.0 φ 16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 15 15
Max. Interunit Height Difference m 12 12
Chargeless m 10 10
Amount of Additional Charge of g/m 20 20
Refrigerant
Indoor Unit FTKC25PVM4 FTKC35PVM4
Front Panel Colour Shiny Pure White Shiny Pure White
H 9.0 (318) 9.3 (328)
M m³/min 6.7 (237) 7.0 (247)
Airflow Rate (cfm)
L 4.4 (155) 4.6 (162)
SL 3.5 (124) 3.6 (127)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.19 0.27
Power Consumption (Rated) W 39 57
Power Factor (Rated) % 93.3 96.0
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 283 × 770 × 203 283 × 770 × 203
Packaged Dimensions (H × W × D) mm 263 × 840 × 344 263 × 840 × 344
Weight (Mass) kg 8 8
Gross Weight (Gross Mass) kg 10 10
Sound
Pressure H / M / L / SL dB(A) 38 / 33 / 25 / 22 39 / 34 / 26 / 22
Level
Outdoor Unit RKC25PVM4 RKC35PVM4
Casing Colour Ivory White Ivory White
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 1YC15AXD 1YC22DXD
Motor Output W 641 913
Refrigerant Type FW68DA FW68DA
Oil Charge L 0.23 0.28
Type R-32 R-32
Refrigerant
Charge kg 0.5 0.7
Airflow Rate H m³/min 27.1 (957) 27.1 (957)
(cfm)
Type Propeller Propeller
Fan
Motor Output W 20 20
Running Current (Rated) A 3.11 4.27
Power Consumption (Rated) W 661 933
Power Factor (Rated) % 96.6 99.3
Starting Current A 2.06 2.64
Dimensions (H × W × D) mm 550 × 658 × 275 550 × 658 × 275
Packaged Dimensions (H × W × D) mm 616 × 788 × 359 616 × 788 × 359
Weight (Mass) kg 23 26
Gross Weight (Gross Mass) kg 26 30
Sound
Pressure H dB(A) 47 - 48 - 48 / 49 - 50 49 - 49 - 50 / 49 - 50
Level
Drawing No. 3D094193C 3D094194C

Note: „ The data are based on the conditions shown in the table below.
Cooling Piping Length Conversion Formulae

Indoor ; 27°CDB / 19°CWB kcal/h = kW × 860


Outdoor ; 35°CDB / 24°CWB 7.5 m Btu/h = kW × 3412
cfm = m³/min × 35.3

Split Type Air Conditioners FTKC-P Series 5


Dimensions EDID041521

4. Dimensions
4.1 Indoor Unit

FTKC15/20/25/35PVM4

AIRFLOW (INDOOR)
THE MARK (→) SHOWS PIPING DIRECTION

PERFORMANCE)
REAR
770

(SPACE FOR
30 MIN.
LEFT RIGHT

INCLUDING
MOUNTING PLATE
205 50 MIN. 50 MIN.
FRONT PANEL FIXING SCREWS 203 (SPACE FOR REQUIRED SPACE (SPACE FOR
(INSIDE) MAINTENANCE) MAINTENANCE)
MANUFACTURER'S
LABEL

SIGNAL RECEIVER

283
OPERATION LAMP TERMINAL BLOCK
TIMER LAMP WITH EARTH
LOW WATT FUNCTION TERMINAL
(INSIDE)
BOTTOM FLAPS INDOOR UNIT ON/OFF SWITCH
GAS PIPE φ9.5 CuT DRAIN HOSE
ROOM TEMP. THERMISTOR (THE LENGTH OF PIPE OUTSIDE
(INSIDE) (CONNECTING PART
THE UNIT: ABOUT 350)
I.D. φ14
LIQUID PIPE φ6.4 CuT O.D. φ16
(THE LENGTH OF PIPE OUTSIDE THE HOSE LENGTH OF OUTSIDE
THE UNIT: ABOUT 400) THE UNIT IS ABOUT 450)
770
SIGNAL TRANSMITTER MODEL NAME

16
PLATE 549 101

6
58 18 BLADE ANGLE

172
UP/DOWN (AUTOMATIC)

283
41.3
COOLING DRY

5˚ 5˚
163

54.5 54

41.3
45˚ 45˚
WALL HOLE FOR EMBEDDED PIPING
FAN φ65 HOLE
RIGHT/LEFT (MANUAL)
WALL HOLE
5˚ φ65 HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER 45˚
45˚ 45˚ 3D089151A
(ARC433A106)

4.2 Outdoor Unit

RKC15/20/25/35PVM4

DRAIN OUTLET MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE
= LESS THAN 1200
(I.Dφ15.9 HOSE FOR CONNECTION 4-HOLES FOR ANCHOR BOLTS
150
WITH DRAIN JOINT) (M8 OR M10)

470 96
100

150

379
11
40

50 50
300
297

50
50

100

HANDLE BRAND NAME LABEL


MANUFACTURE'S LABEL
275 13.5 12 658 50 8 OUTDOOR AIR THERMISTOR

LIQUID
STOP VALVE
(φ6.4CuT)
WIRING
INLET
550

SERVICE
PORT
168
108

155 GAS STOP VALVE


(φ9.5CuT)
INDICATION LABEL (INDONESIA) IN CASE OF REMOVING
FOR INDONESIA MODEL ONLY STOP VALVE COVER

3D089153C

6 Split Type Air Conditioners FTKC-P Series


EDID041521 Wiring Diagrams

5. Wiring Diagrams
5.1 Indoor Unit

FTKC15/20/25/35PVM4

5.2 Outdoor Unit

RKC15/20/25/35PVM4

Split Type Air Conditioners FTKC-P Series 7


Piping Diagrams EDID041521

6. Piping Diagrams
6.1 Indoor Unit

FTKC15/20/25/35PVM4

INDOOR UNIT

HEAT EXCHANGER
7.0CuT
4.8CuT

7.0CuT
THERMISTOR 7.0CuT
ON HEAT EXCH.
7.0CuT

FIELD PIPING CROSS FLOW FAN


(6.4CuT) M
FAN MOTOR
FIELD PIPING 9.5CuT
(9.5CuT)

REFRIGERANT FLOW
COOLING

4D075755C

8 Split Type Air Conditioners FTKC-P Series


EDID041521 Piping Diagrams

6.2 Outdoor Unit

RKC15/20/25PVM4

OUTDOOR UNIT

HEAT EXCHANGER OUTDOOR TEMPERATURE


6.4CuT THERMISTOR
6.4CuT

7.0CuT
HEAT EXCHANGER

MOTOR OPERATED
THERMISTOR

VALVE
6.4CuT 6.4CuT 6.4CuT 6.4CuT

FAN MUFFLER MUFFLER


M

6.4CuT
MOTOR WITH
FILTER
PROPELLER FAN

4.8CuT
6.4CuT

9.5CuT

FIELD PIPING
(6.4CuT)
LIQUID STOP
VALVE
REFRIGERANT FLOW
DISCHARGE PIPE 9.5CuT FIELD PIPING
COMPRESSOR COOLING
THERMISTOR (9.5CuT)
MUFFLER GAS STOP
ACCUMULATOR VALVE

3D094156A

RKC35PVM4

OUTDOOR UNIT

HEAT EXCHANGER OUTDOOR TEMPERATURE


7.0CuT THERMISTOR
9.5CuT

7.0CuT
HEAT EXCHANGER

MOTOR OPERATED
THERMISTOR

VALVE
6.4CuT 6.4CuT 6.4CuT

MUFFLER
FAN
M WITH
MOTOR
6.4CuT

FILTER

PROPELLER FAN
STRAINER
4.8CuT
7.9CuT

9.5CuT

FIELD PIPING
REFRIGERANT FLOW
(6.4CuT)
LIQUID STOP
COOLING
VALVE

DISCHARGE PIPE 9.5CuT FIELD PIPING


THERMISTOR COMPRESSOR (9.5CuT)
MUFFLER GAS STOP
ACCUMULATOR VALVE

3D097010

Split Type Air Conditioners FTKC-P Series 9


Capacity Tables EDID041521

7. Capacity Tables
7.1 Cooling Only

FTKC15PVM4 + RKC15PVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9
BF 0.33

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 1.54 1.38 0.26 1.47 1.34 0.28 1.40 1.31 0.31 1.37 1.30 0.32 1.33 1.28 0.33 1.26 1.25 0.36
16.0 22 1.61 1.35 0.26 1.54 1.33 0.28 1.47 1.30 0.31 1.44 1.28 0.32 1.40 1.27 0.33 1.33 1.24 0.36
18.0 25 1.67 1.45 0.26 1.61 1.42 0.29 1.54 1.40 0.31 1.51 1.39 0.32 1.47 1.37 0.34 1.40 1.34 0.36
19.0 27 1.71 1.56 0.26 1.64 1.53 0.29 1.57 1.51 0.31 1.54 1.50 0.32 1.50 1.48 0.34 1.43 1.46 0.36
22.0 30 1.81 1.52 0.26 1.74 1.49 0.29 1.67 1.47 0.31 1.65 1.46 0.32 1.60 1.45 0.34 1.53 1.43 0.36
24.0 32 1.88 1.49 0.27 1.81 1.47 0.29 1.74 1.45 0.32 1.71 1.44 0.33 1.67 1.42 0.34 1.60 1.40 0.37

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. Ratings shown are net capacities which include a deduction for indoor
fan motor heat.
BF : Bypass factor 2. shows nominal (rated) capacities and power input.
EWB : Entering wet bulb temp. (°C) 3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
EDB : Entering dry bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
TC : Total capacity (kW) 4. About SHC which are not mentioned in the table, please calculate them
with around values in direct proportion.
SHC : Sensible heat capacity (kW) 5. Capacities are based on the following conditions.
PI : Power input (kW) Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
6. Air flow rate (AFR) and Bypass factor (BF) are tabulated in the above
table.
3D094237

FTKC20PVM4 + RKC20PVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9
BF 0.11

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 2.05 1.83 0.38 1.96 1.79 0.42 1.86 1.75 0.46 1.83 1.73 0.47 1.77 1.71 0.49 1.68 1.66 0.53
16.0 22 2.14 1.80 0.39 2.05 1.76 0.42 1.95 1.72 0.46 1.92 1.71 0.47 1.86 1.69 0.50 1.77 1.65 0.53
18.0 25 2.23 1.93 0.39 2.14 1.90 0.42 2.05 1.86 0.46 2.01 1.84 0.48 1.95 1.82 0.50 1.86 1.79 0.54
19.0 27 2.28 2.08 0.39 2.19 2.04 0.43 2.09 2.01 0.46 2.06 1.99 0.48 2.00 1.97 0.50 1.91 1.94 0.54
22.0 30 2.42 2.02 0.39 2.32 1.99 0.43 2.23 1.96 0.47 2.19 1.94 0.48 2.14 1.93 0.50 2.05 1.90 0.54
24.0 32 2.51 1.98 0.39 2.42 1.95 0.43 2.32 1.92 0.47 2.29 1.91 0.48 2.23 1.89 0.51 2.14 1.87 0.54

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. Ratings shown are net capacities which include a deduction for indoor
fan motor heat.
BF : Bypass factor 2. shows nominal (rated) capacities and power input.
EWB : Entering wet bulb temp. (°C) 3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
EDB : Entering dry bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
TC : Total capacity (kW) 4. About SHC which are not mentioned in the table, please calculate them
with around values in direct proportion.
SHC : Sensible heat capacity (kW) 5. Capacities are based on the following conditions.
PI : Power input (kW) Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
6. Air flow rate (AFR) and Bypass factor (BF) are tabulated in the above
table.
3D094238

10 Split Type Air Conditioners FTKC-P Series


EDID041521 Capacity Tables

FTKC25PVM4 + RKC25PVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9
BF 0.10

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 2.56 2.08 0.54 2.44 2.03 0.59 2.33 1.97 0.64 2.28 1.95 0.66 2.21 1.92 0.69 2.10 1.86 0.74
16.0 22 2.68 2.05 0.54 2.56 1.99 0.59 2.44 1.94 0.64 2.40 1.92 0.66 2.33 1.89 0.70 2.21 1.84 0.75
18.0 25 2.79 2.17 0.54 2.68 2.12 0.59 2.56 2.07 0.65 2.51 2.05 0.67 2.44 2.03 0.70 2.33 1.98 0.75
19.0 27 2.85 2.31 0.54 2.73 2.26 0.60 2.62 2.22 0.65 2.57 2.20 0.67 2.50 2.17 0.70 2.38 2.13 0.75
22.0 30 3.02 2.24 0.55 2.91 2.20 0.60 2.79 2.16 0.65 2.74 2.14 0.67 2.67 2.12 0.70 2.56 2.08 0.76
24.0 32 3.14 2.19 0.55 3.02 2.15 0.60 2.90 2.11 0.66 2.86 2.10 0.68 2.79 2.08 0.71 2.67 2.04 0.76

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. Ratings shown are net capacities which include a deduction for indoor
fan motor heat.
BF : Bypass factor 2. shows nominal (rated) capacities and power input.
EWB : Entering wet bulb temp. (°C) 3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
EDB : Entering dry bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
TC : Total capacity (kW) 4. About SHC which are not mentioned in the table, please calculate them
with around values in direct proportion.
SHC : Sensible heat capacity (kW) 5. Capacities are based on the following conditions.
PI : Power input (kW) Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
6. Air flow rate (AFR) and Bypass factor (BF) are tabulated in the above
table.
3D094245

FTKC35PVM4 + RKC35PVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9.3
BF 0.12

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 3.59 2.59 0.76 3.42 2.50 0.83 3.26 2.42 0.91 3.19 2.39 0.94 3.10 2.34 0.98 2.93 2.26 1.05
16.0 22 3.75 2.54 0.76 3.58 2.46 0.84 3.42 2.39 0.91 3.36 2.36 0.94 3.26 2.31 0.98 3.10 2.23 1.06
18.0 25 3.91 2.65 0.77 3.75 2.58 0.84 3.58 2.51 0.91 3.52 2.48 0.94 3.42 2.43 0.99 3.26 2.36 1.06
19.0 27 3.99 2.79 0.77 3.83 2.71 0.84 3.66 2.64 0.92 3.60 2.62 0.95 3.50 2.58 0.99 3.34 2.51 1.06
22.0 30 4.23 2.68 0.78 4.07 2.62 0.85 3.90 2.56 0.92 3.84 2.53 0.95 3.74 2.50 1.00 3.58 2.44 1.07
24.0 32 4.39 2.61 0.78 4.23 2.55 0.85 4.07 2.49 0.93 4.00 2.47 0.96 3.90 2.44 1.00 3.74 2.38 1.07

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. Ratings shown are net capacities which include a deduction for indoor
fan motor heat.
BF : Bypass factor 2. shows nominal (rated) capacities and power input.
EWB : Entering wet bulb temp. (°C) 3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables.
EDB : Entering dry bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
TC : Total capacity (kW) 4. About SHC which are not mentioned in the table, please calculate them
with around values in direct proportion.
SHC : Sensible heat capacity (kW) 5. Capacities are based on the following conditions.
PI : Power input (kW) Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
6. Air flow rate (AFR) and Bypass factor (BF) are tabulated in the above
table.
3D094246A

Split Type Air Conditioners FTKC-P Series 11


Capacity Tables EDID041521

7.2 Capacity Correction Factor by the Length of Refrigerant Piping (Reference)


The cooling capacity of the unit has to be corrected in accordance with the length of refrigerant piping —
the distance between the indoor unit and the outdoor unit.

(R-32)
(%)
100
Capacity correction factor

90

Range of the
refrigerant
80 additional
charge

5 10 15 (m)

Piping length

Note: The graph shows the factor when additional refrigerant of the proper quantity is charged.

12 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Limit

8. Operation Limit
RKC15/20/25/35PVM4

50

46

40

Outdoor temp. (˚CDB)

Continuous operation

Pull-down period
30

20
19.4

10 14 20 23 28 30
Indoor temp. (˚CWB)
Notes:
The graph is based on
the following conditions.
• Equivalent piping length 7.5m
• Level difference 0m
• Airflow rate High
4D073983H

Split Type Air Conditioners FTKC-P Series 13


Sound Level EDID041521

9. Sound Level
9.1 Measuring Location

Indoor Unit Outdoor Unit

1m 1m

0.8 m
MICROPHONE

MICROPHONE

Notes: 1. Operation sound is measured in an anechoic chamber.


2. The data are based on the conditions shown in the table below.

Cooling Piping Length


Indoor ; 27°CDB / 19°CWB 5m
Outdoor ; 35°CDB / 24°CWB

9.2 Indoor Unit


FTKC15PVM4 FTKC20PVM4

70 OVER ALL ( dB ) 70 OVER ALL ( dB )


NC-70 NC-70

50/60Hz 50/60Hz 50/60Hz 50/60Hz


OCTAVE BAND SOUND PRESSURE LEVEL

OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V 60 SCALE 220-240/220-230V 220-240/220-230V


(H) (L) (H) (L)
NC-60 NC-60
A 38 25 A 38 25
50 ( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz POWER SOURCE 220-240/220-230V 50/60Hz
40 40
NC-40 JIS STANDARD NC-40 JIS STANDARD
220-240/220-230V 50/60Hz(H) 220-240/220-230V 50/60Hz(H)
30 220-240/220-230V 50/60Hz(L) 30 220-240/220-230V 50/60Hz(L)
NC-30 NC-30
Cooling Cooling

20 20
APPROXIMATE NC-20 APPROXIMATE NC-20
THRESHOLD HEARING THRESHOLD HEARING
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D094216 63 125 250 500 1000 2000 4000 8000 4D094217
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

FTKC25PVM4 FTKC35PVM4

70 OVER ALL ( dB ) 70 OVER ALL ( dB )


NC-70 NC-70

50/60Hz 50/60Hz 50/60Hz 50/60Hz


OCTAVE BAND SOUND PRESSURE LEVEL

OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V 60 SCALE 220-240/220-230V 220-240/220-230V


NC-60 (H) (L) NC-60 (H) (L)
A 38 25 A 39 26
50 ( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz POWER SOURCE 220-240/220-230V 50/60Hz
40 40
NC-40 JIS STANDARD NC-40 JIS STANDARD
220-240/220-230V 50/60Hz(H) 220-240/220-230V 50/60Hz(H)
30 220-240/220-230V 50/60Hz(L) 30 220-240/220-230V 50/60Hz(L)
NC-30 NC-30
Cooling Cooling

20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D094218 63 125 250 500 1000 2000 4000 8000 4D094220
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

14 Split Type Air Conditioners FTKC-P Series


EDID041521 Sound Level

9.3 Outdoor Unit


RKC15PVM4 RKC20PVM4

COOLING COOLING
70 OVER ALL ( dB ) 70 OVER ALL ( dB )
NC-70 NC-70
OCTAVE BAND SOUND PRESSURE LEVEL

OCTAVE BAND SOUND PRESSURE LEVEL


50Hz 60Hz 50Hz 60Hz
60 SCALE 220-230-240V 220-230V 60 SCALE 220-230-240V 220-230V
NC-60 NC-60
A 46-47-47 48-49 A 46-47-47 48-49
50 ( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

dB(0dB=0.0002µ bar)
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz(H) POWER SOURCE 220-240/220-230V 50/60Hz (H)
40 40
NC-40 JIS STANDARD (JIS9612) NC-40 JIS STANDARD (JIS9612)
220-240/220-230V 50/60Hz(H) 220-240/220-230V 50/60Hz (H)
30 30
NC-30 NC-30

20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D094254 63 125 250 500 1000 2000 4000 8000 4D094256
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

RKC25PVM4 RKC35PVM4

COOLING COOLING
70 OVER ALL ( dB ) 70 OVER ALL ( dB )
NC-70 NC-70
OCTAVE BAND SOUND PRESSURE LEVEL

OCTAVE BAND SOUND PRESSURE LEVEL


50Hz 60Hz 50Hz 60Hz
60 SCALE 220-230-240V 220-230V 60 SCALE
220-230-240V 220-230V
NC-60 NC-60
A 47-48-48 49-50 A 49-49-50 49-50
50 ( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz(H) POWER SOURCE 220-240/220-230V 50/60Hz(H)
40 40
NC-40 JIS STANDARD (JIS9612) NC-40 JIS STANDARD (JIS9612)
220-240/220-230V 50/60Hz(H) 220-240/220-230V 50/60Hz(H)
30 30
NC-30 NC-30

20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D094257 63 125 250 500 1000 2000 4000 8000 4D094258
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

Split Type Air Conditioners FTKC-P Series 15


Electric Characteristics EDID041521

10. Electric Characteristics

Power Supply Compressor OFM IFM


Indoor Unit Outdoor Unit
Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA
50 - 220 1.8 0.22 0.19
50 - 230 Max. 50 Hz, 264 V 1.7 0.21 0.18
Min. 50 Hz, 198 V
FTKC15PVM4 RKC15PVM4 50 - 240 8.00 15 37 1.6 20 0.20 16 0.17
60 - 220 Max. 60 Hz, 253 V 1.8 0.22 0.19
60 - 230 Min. 60 Hz, 198 V 1.7 0.21 0.18
50 - 220 2.2 0.22 0.19
Max. 50 Hz, 264 V
50 - 230 Min. 50 Hz, 198 V 2.1 0.21 0.18
FTKC20PVM4 RKC20PVM4 50 - 240 8.00 15 56 2.0 20 0.20 16 0.17
60 - 220 Max. 60 Hz, 253 V 2.2 0.22 0.19
60 - 230 Min. 60 Hz, 198 V 2.1 0.21 0.18
50 - 220 2.9 0.22 0.19
Max. 50 Hz, 264 V
50 - 230 Min. 50 Hz, 198 V 2.8 0.21 0.18
FTKC25PVM4 RKC25PVM4 50 - 240 8.00 15 72 2.7 20 0.20 16 0.17
60 - 220 Max. 60 Hz, 253 V 2.9 0.22 0.19
60 - 230 Min. 60 Hz, 198 V 2.8 0.21 0.18
50 - 220 4.1 0.22 0.27
Max. 50 Hz, 264 V
50 - 230 Min. 50 Hz, 198 V 3.9 0.21 0.26
FTKC35PVM4 RKC35PVM4 50 - 240 8.50 15 74 3.7 20 0.20 16 0.24
60 - 220 Max. 60 Hz, 253 V 4.1 0.22 0.27
60 - 230 Min. 60 Hz, 198 V 3.9 0.21 0.26

Symbols: Notes:
MCA : Min. circuit amps (A) 1. RLA is based on the following conditions.
Indoor temp. 27°CDB / 19°CWB
MFA : Max. fuse amps (A) Outdoor temp. 35°CDB
RHz : Rated operating frequency (Hz) 2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
RLA : Rated load amps (A) 4. Instead of fuse, use circuit breaker.
OFM : Outdoor fan motor 5. Be sure to install an earth leak detector.
(This unit uses an inverter, which means that an earth leak
IFM : Indoor fan motor detector capable of handling high harmonics must be used in
W : Fan motor rated output (W) order to prevent malfunctioning of the earth leak detector.)
FLA : Full load amps (A)
3D094224

16 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

11. Installation Manual


11.1 English

Split Type Air Conditioners FTKC-P Series 17


Installation Manual EDID041521

18 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 19


Installation Manual EDID041521

20 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 21


Installation Manual EDID041521

22 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 23


Installation Manual EDID041521

24 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 25


Installation Manual EDID041521

EN_3P383016-1

26 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

11.2 Indonesian

Split Type Air Conditioners FTKC-P Series 27


Installation Manual EDID041521

28 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 29


Installation Manual EDID041521

30 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 31


Installation Manual EDID041521

32 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 33


Installation Manual EDID041521

34 Split Type Air Conditioners FTKC-P Series


EDID041521 Installation Manual

Split Type Air Conditioners FTKC-P Series 35


Installation Manual EDID041521

ID_3P383016-1

36 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

12. Operation Manual


12.1 English

Split Type Air Conditioners FTKC-P Series 37


Operation Manual EDID041521

38 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 39


Operation Manual EDID041521

40 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 41


Operation Manual EDID041521

42 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 43


Operation Manual EDID041521

44 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 45


Operation Manual EDID041521

46 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 47


Operation Manual EDID041521

48 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 49


Operation Manual EDID041521

50 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 51


Operation Manual EDID041521

52 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 53


Operation Manual EDID041521

54 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 55


Operation Manual EDID041521

56 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 57


Operation Manual EDID041521

58 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 59


Operation Manual EDID041521

EN_3P383015-1A

60 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

12.2 Indonesian

Split Type Air Conditioners FTKC-P Series 61


Operation Manual EDID041521

62 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 63


Operation Manual EDID041521

64 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 65


Operation Manual EDID041521

66 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 67


Operation Manual EDID041521

68 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 69


Operation Manual EDID041521

70 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 71


Operation Manual EDID041521

72 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 73


Operation Manual EDID041521

74 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 75


Operation Manual EDID041521

76 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 77


Operation Manual EDID041521

78 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 79


Operation Manual EDID041521

80 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 81


Operation Manual EDID041521

82 Split Type Air Conditioners FTKC-P Series


EDID041521 Operation Manual

Split Type Air Conditioners FTKC-P Series 83


Operation Manual EDID041521

ID_3P383015-1A

84 Split Type Air Conditioners FTKC-P Series


EDID041521 Optional Accessories

13. Optional Accessories


13.1 Option List
13.1.1 Indoor Unit

Option Name Model Name


1 Titanium apatite photocatalytic air-purifying filter (without frame) ★ KAF970A46
2 Remote controller loss prevention with chain KKF917A4

Note: ★ Standard accessory

13.1.2 Outdoor Unit

Option Name Model Name


1 Air direction adjustment grille KPW937B4
2 Drain plug KKP937A4

Split Type Air Conditioners FTKC-P Series 85


Optional Accessories EDID041521

13.2 <KPW937B4> Air Direction Adjustment Grille

4P202735-1

86 Split Type Air Conditioners FTKC-P Series


Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

Specifications, designs and other content appearing in this brochure are current as of May 2015 but subject to change without notice.

c All rights reserved

AK