EDID041611

Split Type Air Conditioners


- Cooling Only -

FTKC-Q Series
EDID041611

Split Type
Air Conditioners
FTKC-Q Series
FTKC25QVM4 RKC25QVM4
FTKC35QVM4 RKC35QVM4
Cooling Only FTKC50QVM4 RKC50QVM4
FTKC60QVM4 RKC60QVM4
FTKC71QVM4 RKC71QVM4
1. Power Supply ..........................................................................................3
2. Functions.................................................................................................4
3. Specifications ..........................................................................................5
4. Dimensions .............................................................................................8
4.1 Indoor Unit................................................................................................8
4.2 Outdoor Unit .............................................................................................9
5. Wiring Diagrams....................................................................................10
5.1 Indoor Unit..............................................................................................10
5.2 Outdoor Unit ...........................................................................................11
6. Piping Diagrams....................................................................................12
6.1 Indoor Unit..............................................................................................12
6.2 Outdoor Unit ...........................................................................................13
7. Capacity Tables ....................................................................................15
7.1 Cooling Only...........................................................................................15
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ............................................................................................18
8. Operation Limit......................................................................................19
9. Sound Level ..........................................................................................20
9.1 Measuring Location ................................................................................20
9.2 Indoor Unit..............................................................................................20
9.3 Outdoor Unit ...........................................................................................21
10.Electric Characteristics..........................................................................22
11.Installation Manual ................................................................................23
11.1 English....................................................................................................23
11.2 Indonesian..............................................................................................43
12.Operation Manual..................................................................................63
12.1 English....................................................................................................63
12.2 Indonesian............................................................................................114
13.Optional Accessories ..........................................................................165
13.1 Option List ............................................................................................165
13.2 <BRP072A42> Wireless LAN Connecting Adaptor..............................166
13.3 <KRP067A41> Remote Control PC-Board Set ....................................174
13.4 <KRP980B2> Remote Control PC-Board Set ......................................178
13.5 <KPW937E4> Air Direction Adjustment Grille......................................182

Split Type Air Conditioners FTKC-Q Series 1


EDID041611

2 Split Type Air Conditioners FTKC-Q Series


EDID041611 Power Supply

1. Power Supply
Indoor Unit Outdoor Unit Power Supply
FTKC25QVM4 RKC25QVM4
FTKC35QVM4 RKC35QVM4
FTKC50QVM4 RKC50QVM4 1 phase, 220 - 230 - 240 V, 50 Hz
1 phase, 220 - 230 V, 60 Hz
FTKC60QVM4 RKC60QVM4
FTKC71QVM4 RKC71QVM4

Note: Power Supply Intake ; Outdoor Unit

Split Type Air Conditioners FTKC-Q Series 3


Functions EDID041611

2. Functions

FTKC50/60/71QVM4

FTKC50/60/71QVM4
RKC50/60/71QVM4

RKC50/60/71QVM4
FTKC25/35QVM4

FTKC25/35QVM4
RKC25/35QVM4

RKC25/35QVM4
Category Functions Category Functions

Basic Functions Inverter (with inverter power control) z z Health & Air-purifying filter — —
Cleanliness
Operation limit for cooling (°CDB) 19.4 19.4 Photocatalytic deodorising filter — —
~ 46 ~ 46
Air-purifying filter with photocatalytic — —
Operation limit for heating (°CWB) — — deodorising function
PAM control z z Titanium apatite photocatalytic
air-purifying filter z z
Standby electricity saving z z
Compressor Oval scroll compressor — — Air filter (prefilter) z z
Swing compressor z z Wipe-clean flat panel z z
Rotary compressor — — Washable grille — —
Reluctance DC motor z z MOULD PROOF operation — —
Comfortable Power-airflow flap z — Heating dry operation — —
Airflow
Power-airflow dual flaps — z Good-sleep cooling operation — —
Power-airflow diffuser — — Odour removing z z
Wide-angle louvres z z Timer WEEKLY TIMER operation — —
Auto-swing (up and down) z z 24-hour ON/OFF TIMER — —
Auto-swing (right and left) — — Count up-down ON/OFF TIMER z z
3-D airflow — — NIGHT SET mode z z
COMFORT AIRFLOW operation z z Worry Free Auto-restart (after power failure) z z
(Reliability &
Comfort Control Auto fan speed z z Durability) Self-diagnosis (R/C, LED) z z
Indoor unit quiet operation z z Wiring error check function — —
NIGHT QUIET mode (automatic) — — Anti-corrosion treatment of outdoor
heat exchanger z z
OUTDOOR UNIT QUIET operation z z
(manual) Flexibility Multi-split/split type compatible — —
INTELLIGENT EYE operation z z indoor unit
Quick warming function — — Flexible power supply
z z
Hot-start function — — correspondence
Automatic defrosting — — Chargeless 10 m 10 m
Operation Automatic operation — — Either side drain (right or left) z z
Programme dry operation z z Power selection — —
Fan only z z Remote Control 5-room centralised controller
(option) — —
Lifestyle New POWERFUL operation — —
Convenience (non-inverter) Remote control adaptor (normal — —
Inverter POWERFUL operation z z open pulse contact) (option)
Priority-room setting — — Remote control adaptor (normal
open contact) (option) — —
COOL/HEAT mode lock — —
HOME LEAVE operation — — DIII-NET compatible (adaptor)
(option) — —
LOW WATT operation z —
ECONO operation — z Wireless LAN connection (option) z z
Indoor unit ON/OFF button z z Remote Wireless z z
Controller
Signal receiving sign z z Wired — —
R/C with back light — —
Temperature display — —
Note: z : Available
— : Not available

4 Split Type Air Conditioners FTKC-Q Series


EDID041611 Specifications

3. Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Indoor Unit FTKC25QVM4 FTKC35QVM4
Model
Outdoor Unit RKC25QVM4 RKC35QVM4
kW 2.5 (1.0 ~ 3.4) 3.5 (1.3 ~ 4.1)
Capacity Btu/h 8,500 (3,400 ~ 11,600) 11,900 (4,400 ~ 14,000)
Rated (Min. ~ Max.)
kcal/h 2,150 (860 ~ 2,920) 3,010 (1,120 ~ 3,530)
Moisture Removal L/h 1.2 1.7
Running Current (Rated) A 3.20 4.5
Power Consumption W 680 (210 ~ 1,100) 960 (250 ~ 1,455)
Rated (Min. ~ Max.)
Power Factor (Rated) % 96.6 97.0
COP (Rated) W/W 3.67 3.65
Liquid mm φ 6.4 φ 6.4
Piping φ 9.5 φ 9.5
Connections Gas mm
Drain mm φ 16.0 φ 16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 15 15
Max. Interunit Height Difference m 12 12
Chargeless m 10 10
Amount of Additional Charge of g/m 20 20
Refrigerant
Indoor Unit FTKC25QVM4 FTKC35QVM4
Front Panel Colour Shiny White Shiny White
H 9.0 (318) 10.8 (381)
M m³/min 7.4 (261) 8.2 (290)
Airflow Rate (cfm)
L 5.3 (187) 6.1 (215)
SL 2.6 (92) 4.9 (173)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 19.5 19.5
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.13 0.19
Power Consumption (Rated) W 12 19
Power Factor (Rated) % 42.0 45.5
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 283 × 770 × 223 283 × 770 × 223
Packaged Dimensions (H × W × D) mm 320 × 830 × 360 320 × 830 × 360
Weight (Mass) kg 8 8
Gross Weight (Gross Mass) kg 11 11
Sound
Pressure H / M / L / SL dB(A) 38 / 33 / 25 / 19 39 / 34 / 26 / 22
Level
Outdoor Unit RKC25QVM4 RKC35QVM4
Casing Colour Ivory White Ivory White
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 1YC15AXD 1YC22DXD
Motor Output W 641 913
Refrigerant Type FW68DA FW68DA
Oil Charge L 0.225 0.275
Type R-32 R-32
Refrigerant
Charge kg 0.50 0.70
Airflow Rate H m³/min 27.1 (957) 27.1 (957)
(cfm)
Type Propeller Propeller
Fan
Motor Output W 26 26
Running Current (Rated) A 3.07 4.31
Power Consumption (Rated) W 668 941
Power Factor (Rated) % 98.9 99.2
Starting Current A 2.06 2.64
Dimensions (H × W × D) mm 550 × 658 × 275 550 × 658 × 275
Packaged Dimensions (H × W × D) mm 616 × 788 × 359 616 × 788 × 359
Weight (Mass) kg 23 26
Gross Weight (Gross Mass) kg 26 30
Sound
Pressure H / SL dB(A) 47 / 44 49 / 45
Level
Drawing No. 3D101527A 3D101531B

Notes: 1. SL: The Quiet fan level of the airflow rate setting.
2. The data are based on the conditions shown in the table below. Conversion Formulae
Cooling Piping Length kcal/h = kW × 860
Btu/h = kW × 3412
Indoor ; 27°CDB / 19°CWB 7.5 m cfm = m³/min × 35.3
Outdoor ; 35°CDB / 24°CWB

Split Type Air Conditioners FTKC-Q Series 5


Specifications EDID041611

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Indoor Unit FTKC50QVM4 FTKC60QVM4
Model
Outdoor Unit RKC50QVM4 RKC60QVM4
kW 5.2 (1.4 ~ 6.0) 6.0 (1.4 ~ 6.7)
Capacity Btu/h 17,700 (4,800 ~ 20,500) 20,500 (4,800 ~ 22,900)
Rated (Min. ~ Max.)
kcal/h 4,470 (1,200 ~ 5,160) 5,160 (1,200 ~ 5,765)
Moisture Removal L/h 2.9 3.9
Running Current (Rated) A 6.3 8.0
Power Consumption W 1,365 (260 ~ 1,730) 1,740 (300 ~ 2,060)
Rated (Min. ~ Max.)
Power Factor (Rated) % 98.5 98.9
COP (Rated) W/W 3.80 3.45
Liquid mm φ 6.4 φ 6.4
Piping φ 12.7 φ 12.7
Connections Gas mm
Drain mm φ 16.0 φ 16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30 30
Max. Interunit Height Difference m 20 20
Chargeless m 10 10
Amount of Additional Charge of g/m 20 20
Refrigerant
Indoor Unit FTKC50QVM4 FTKC60QVM4
Front Panel Colour Shiny White Shiny White
H 16.7 (590) 16.7 (590)
M m³/min 15.3 (540) 15.3 (540)
Airflow Rate (cfm)
L 11.8 (417) 11.8 (417)
SL 8.3 (293) 8.3 (293)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 46 46
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.24 0.24
Power Consumption (Rated) W 46 46
Power Factor (Rated) % 87.1 87.1
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 295 × 990 × 263 295 × 990 × 263
Packaged Dimensions (H × W × D) mm 386 × 1,102 × 389 386 × 1,102 × 389
Weight (Mass) kg 13 13
Gross Weight (Gross Mass) kg 18 18
Sound
Pressure H / M / L / SL dB(A) 44 / 40 / 35 / 29 45 / 41 / 36 / 29
Level
Outdoor Unit RKC50QVM4 RKC60QVM4
Casing Colour Ivory White Ivory White
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 1YC36DXD 1YC36DXD
Motor Output W 1,200 1,200
Refrigerant Type FW68DA FW68DA
Oil Charge L 0.35 0.35
Type R-32 R-32
Refrigerant
Charge kg 1.0 1.0
Airflow Rate H m³/min 35.8 (1,263) 35.8 (1,263)
(cfm)
Type Propeller Propeller
Fan
Motor Output W 38 38
Running Current (Rated) A 6.0 7.8
Power Consumption (Rated) W 1,281 1,656
Power Factor (Rated) % 97.1 96.5
Starting Current A — —
Dimensions (H × W × D) mm 595 × 845 × 300 595 × 845 × 300
Packaged Dimensions (H × W × D) mm 660 × 995 × 410 660 × 995 × 410
Weight (Mass) kg 36 36
Gross Weight (Gross Mass) kg 42 42
Sound
Pressure H / SL dB(A) 49 / 43 50 / 43
Level
Drawing No. 3D101281A 3D101282B

Notes: 1. SL: The Quiet fan level of the airflow rate setting.
2. The data are based on the conditions shown in the table below. Conversion Formulae
Cooling Piping Length kcal/h = kW × 860
Btu/h = kW × 3412
Indoor ; 27°CDB / 19°CWB 7.5 m cfm = m³/min × 35.3
Outdoor ; 35°CDB / 24°CWB

6 Split Type Air Conditioners FTKC-Q Series


EDID041611 Specifications

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Indoor Unit FTKC71QVM4
Model
Outdoor Unit RKC71QVM4
kW 7.1 (2.1 ~ 7.5)
Capacity Btu/h 24,200 (7,200 ~ 25,600)
Rated (Min. ~ Max.)
kcal/h 6,110 (1,806 ~ 6,453)
Moisture Removal L/h 4.5
Running Current (Rated) A 10.9
Power Consumption W 2,365 (400 ~ 2,550)
Rated (Min. ~ Max.)
Power Factor (Rated) % 98.6
COP (Rated) W/W 3.00
Liquid mm φ 6.4
Piping φ 15.9
Connections Gas mm
Drain mm φ 16.0
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30
Max. Interunit Height Difference m 20
Chargeless m 10
Amount of Additional Charge of g/m 20
Refrigerant
Indoor Unit FTKC71QVM4
Front Panel Colour Shiny White
H 17.3 (611)
M m³/min 14.7 (519)
Airflow Rate (cfm)
L 12.2 (431)
SL 9.3 (328)
Type Cross Flow Fan
Fan Motor Output W 46
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof
Running Current (Rated) A 0.25
Power Consumption (Rated) W 48
Power Factor (Rated) % 87.3
Temperature Control Microcomputer Control
Dimensions (H × W × D) mm 295 × 990 × 263
Packaged Dimensions (H × W × D) mm 386 × 1,102 × 389
Weight (Mass) kg 13
Gross Weight (Gross Mass) kg 18
Sound
Pressure H / M / L / SL dB(A) 46 / 42 / 37 / 31
Level
Outdoor Unit RKC71QVM4
Casing Colour Ivory White
Type Hermetically Sealed Swing Type
Compressor Model 2YC40AXD
Motor Output W 1,300
Refrigerant Type FW68DA
Oil Charge L 0.40
Type R-32
Refrigerant
Charge kg 1.05
Airflow Rate H m³/min 40.1 (1,415)
(cfm)
Type Propeller
Fan
Motor Output W 38
Running Current (Rated) A 10.6
Power Consumption (Rated) W 2,279
Power Factor (Rated) % 97.7
Starting Current A —
Dimensions (H × W × D) mm 595 × 845 × 300
Packaged Dimensions (H × W × D) mm 660 × 995 × 410
Weight (Mass) kg 40
Gross Weight (Gross Mass) kg 45
Sound
Pressure H / SL dB(A) 51 / 46
Level
Drawing No. 3D101283B

Notes: 1. SL: The Quiet fan level of the airflow rate setting.
2. The data are based on the conditions shown in the table below. Conversion Formulae
Cooling Piping Length kcal/h = kW × 860
Btu/h = kW × 3412
Indoor ; 27°CDB / 19°CWB 7.5 m cfm = m³/min × 35.3
Outdoor ; 35°CDB / 24°CWB

Split Type Air Conditioners FTKC-Q Series 7


Dimensions EDID041611

4. Dimensions
4.1 Indoor Unit

FTKC25/35QVM4

THE MARK (→) SHOWS PIPING DIRECTION AIRFLOW (INDOOR)

PERFORMANCE)
REAR 770

(SPACE FOR
30 MIN
LEFT RIGHT
INCLUDING
MOUNTING PLATE
225
FRONT PANEL FIXING SCREWS 223 50 MIN 50 MIN
(INSIDE)
(SPACE FOR REQUIRED SPACE (SPACE FOR
MAINTENANCE) MAINTENANCE)
GENERAL RATING
NAME PLATE

283
TERMINAL BLOCK
WITH EARTH
BOTTOM TERMINAL
INTELLIGENT EYE SENSOR (INSIDE)
FLAPS
SIGNAL RECEIVER GAS PIPE φ9.5mm CuT DRAIN HOSE
OPERATION LAMP (THE LENGTH OF PIPE OUTSIDE (CONNECTING PART
TIMER LAMP THE UNIT: ABOUT 350mm)
O.D. φ16mm
INTELLIGENT EYE LAMP LIQUID PIPE φ6.4mm CuT (THE HOSE LENGTH OF OUTSIDE
INDOOR UNIT ON/OFF SWITCH (THE LENGTH OF PIPE OUTSIDE THE UNIT IS ABOUT 465mm)
ROOM TEMP. THERMISTOR THE UNIT: ABOUT 400mm)
(INSIDE)
MODEL NAME
PLATE
STANDARD LOCATIONS OF WALL HOLES
SIGNAL TRANSMITTER BLADE ANGLE 770
1-7/8 (48mm) 13/16 (20mm) UP/DOWN (AUTOMATIC) RIGHT/LEFT

14.6
536.6 116.5
7.9
(MANUAL)
COOLING DRY
7-1/16 (180mm)

5˚ 5˚
45˚
45˚
285

44.5
40˚ 40˚
FAN
44.5

0˚ 48 48
WALL HOLE FOR EMBEDDED PIPING WALL HOLE
φ65mm HOLE φ65mm HOLE
WIRELESS REMOTE CONTROLLER 65˚
3D101342
(ARC480A23)

FTKC50/60/71QVM4

8 Split Type Air Conditioners FTKC-Q Series


EDID041611 Dimensions

4.2 Outdoor Unit

RKC25/35QVM4

DRAIN OUTLET WALL HEIGHT ON AIR OUTLET SIDE


MINIMUM SPACE FOR AIR PASSAGE =LESS THAN 1200
(I.Dφ 15.9 HOSE FOR CONNECTION

150
4-HOLES FOR ANCHOR BOLTS
WITH DRAIN JOINT) (M8 OR M10)

470 96
379

11

100

150
40

50 50

300
50

297

50

100
HANDLE BRAND NAME LABEL MANUFACTURE'S LABEL
275 13.5 12 658 50 8 OUTDOOR AIR THERMISTOR

LIQUID
STOP VALVE
WIRING (φ6.4 CuT)
INLET
550

SERVICE
PORT

168
108
155
GAS STOP VALVE
INDICATION LABEL (INDONESIA) (φ9.5 CuT)
FOR INDONESIA MODEL ONLY
IN CASE OF REMOVING
STOP VALVE COVER

3D089153E

RKC50/60/71QVM4

WALL HEIGHT ON AIR OUTLET SIDE


MINIMUM SPACE FOR AIR PASSAGE =LESS THAN 1200

150
DRAIN OUTLET
I.D. φ 18 HOSE FOR CONNECTION

845 78
300
100

350

131 573.5
50 50
300

50
342

326

300

100

350

4-HOLE FOR ANCHOR BOLTS


7

20

(M8 OR M10)
IN CASE OF REMOVING
STOP VALVE COVER OUTDOOR AIR TEMPERATURE
BRAND NAME LABEL NAME PLATE TERMINAL STRIP THERMISTOR
BRAND NAME LABEL
(DEPEND ON PART LIST) WIRING INLET WITH EARTH TERMINAL
595

60
105

LIQUID STOP VALVE


(φ 6.4 CuT) 144 20

SERVICE PORT
GAS STOP VALVE
(φ 12.7 CuT FOR CLASS 40, 50, 60, 18, 24)
(φ 15.9 CuT FOR CLASS 71, 28)
3D098640

Split Type Air Conditioners FTKC-Q Series 9


Wiring Diagrams EDID041611

5. Wiring Diagrams
5.1 Indoor Unit

FTKC25/35QVM4

FTKC50/60/71QVM4

10 Split Type Air Conditioners FTKC-Q Series


EDID041611 Wiring Diagrams

5.2 Outdoor Unit

RKC25/35QVM4

RKC50/60/71QVM4

Split Type Air Conditioners FTKC-Q Series 11


Piping Diagrams EDID041611

6. Piping Diagrams
6.1 Indoor Unit
FTKC25/35QVM4 FTKC50/60QVM4

INDOOR UNIT INDOOR UNIT

6.4 CuT
6.4 CuT HEAT EXCHANGER
DISTRIBUTOR
HEAT EXCHANGER

THERMISTOR
ON HEAT EXCH.
THERMISTOR
CROSS FLOW FAN ON HEAT EXCH.
FIELD PIPING
CROSS FLOW FAN 6.4 CuT M
FIELD PIPING
6.4 CuT M FAN MOTOR
HEADER
FIELD PIPING FAN MOTOR

9.5 CuT FIELD PIPING


9.5 CuT
12.7 CuT 12.7 CuT

REFRIGERANT FLOW REFRIGERANT FLOW


COOLING COOLING

4D095912B 4D101258

FTKC71QVM4

INDOOR UNIT

6.4 CuT

DISTRIBUTOR
HEAT EXCHANGER

THERMISTOR
CROSS FLOW FAN ON HEAT EXCH.
FIELD PIPING
6.4 CuT M
FAN MOTOR
HEADER

FIELD PIPING
15.9 CuT 12.7 CuT

REFRIGERANT FLOW
COOLING

4D101259

12 Split Type Air Conditioners FTKC-Q Series


EDID041611 Piping Diagrams

6.2 Outdoor Unit

RKC25QVM4

OUTDOOR UNIT
HEAT EXCHANGER OUTDOOR TEMPERATURE
6.4 CuT THERMISTOR
6.4 CuT

7.0 CuT
HEAT EXCHANGER

MOTOR OPERATED
THERMISTOR

VALVE
6.4 CuT 6.4 CuT 6.4 CuT 6.4 CuT

FAN MUFFLER MUFFLER

6.4 CuT
M
MOTOR WITH
FILTER
PROPELLER FAN

4.8 CuT
6.4 CuT

9.5 CuT

FIELD PIPING
LIQUID STOP (6.4 CuT)
VALVE
REFRIGERANT FLOW
DISCHARGE PIPE 9.5 CuT FIELD PIPING
COMPRESSOR COOLING
THERMISTOR GAS STOP (9.5 CuT)
MUFFLER
ACCUMULATOR VALVE

3D094156D

RKC35QVM4

OUTDOOR UNIT
OUTDOOR TEMPERATURE
7.0 CuT HEAT EXCHANGER THERMISTOR
9.5 CuT

7.0 CuT
HEAT EXCHANGER

MOTOR OPERATED
THERMISTOR

VALVE
6.4 CuT 6.4 CuT 6.4 CuT

FAN MUFFLER
6.4 CuT

M MOTOR WITH
FILTER

PROPELLER FAN
STRAINER
4.8 CuT
7.9 CuT

9.5 CuT

FIELD PIPING
REFRIGERANT FLOW
(6.4 CuT)
LIQUID STOP
COOLING
VALVE

DISCHARGE PIPE 9.5 CuT FIELD PIPING


THERMISTOR COMPRESSOR (9.5 CuT)
MUFFLER GAS STOP
ACCUMULATOR VALVE

3D097010B

Split Type Air Conditioners FTKC-Q Series 13


Piping Diagrams EDID041611

RKC50/60QVM4

OUTDOOR UNIT
HEAT EXCHANGER
7.0 CuT
7.0 CuT HEAT
EXCHANGER
THERMISTOR
6.4 CuT
6.4 CuT 6.4 CuT
MUFFLER WITH
FILTER
6.4 CuT
MUFFLER WITH
FILTER LIQUID STOP FIELD PIPING
M 6.4 CuT VALVE (6.4 CuT)
6.4 CuT

MOTOR OPERATED
VALVE
PROPELLER FAN FIELD PIPING
7.9 CuT

(12.7 CuT)
12.7 CuT 12.7 CuT

MUFFLER GAS STOP


VALVE WITH
SERVICE PORT
ACCUMULATOR

COMPRESSOR

REFRIGERANT FLOW
COOLING

4D101253

RKC71QVM4

OUTDOOR UNIT

HEAT EXCHANGER
7.0 CuT

7.0 CuT HEAT


EXCHANGER
THERMISTOR
6.4 CuT

6.4 CuT 6.4 CuT


MUFFLER WITH
FILTER
6.4 CuT
MUFFLER WITH
FILTER LIQUID STOP
M VALVE FIELD PIPING
6.4 CuT
6.4 CuT (6.4 CuT)

MOTOR OPERATED
VALVE
PROPELLER FAN
FIELD PIPING
7.9 CuT

12.7 CuT 12.7 CuT (15.9 CuT)

MUFFLER GAS STOP


VALVE WITH
SERVICE PORT
ACCUMULATOR

COMPRESSOR

REFRIGERANT FLOW
COOLING

4D101319A

14 Split Type Air Conditioners FTKC-Q Series


EDID041611 Capacity Tables

7. Capacity Tables
7.1 Cooling Only

FTKC25QVM4 + RKC25QVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9
BF 0.08

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 2.46 2.05 0.52 2.35 2.00 0.58 2.23 1.95 0.63 2.28 1.97 0.64 2.21 1.94 0.67 2.10 1.88 0.72
16.0 22 2.57 2.02 0.53 2.46 1.97 0.58 2.34 1.92 0.63 2.40 1.94 0.65 2.33 1.91 0.68 2.21 1.86 0.73
18.0 25 2.68 2.15 0.53 2.57 2.10 0.58 2.46 2.05 0.63 2.51 2.08 0.65 2.44 2.05 0.68 2.33 2.00 0.73
19.0 27 2.73 2.29 0.53 2.62 2.25 0.58 2.51 2.21 0.63 2.57 2.23 0.65 2.50 2.20 0.68 2.38 2.16 0.73
22.0 30 2.90 2.22 0.54 2.79 2.18 0.59 2.68 2.15 0.64 2.74 2.17 0.65 2.67 2.14 0.68 2.56 2.10 0.73
24.0 32 3.01 2.17 0.54 2.90 2.14 0.59 2.79 2.10 0.64 2.86 2.13 0.66 2.79 2.10 0.69 2.67 2.07 0.74

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D101502

FTKC35QVM4 + RKC35QVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 10.8
BF 0.08

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 3.44 2.70 0.74 3.28 2.62 0.81 3.13 2.55 0.88 3.19 2.58 0.91 3.10 2.53 0.95 2.93 2.45 1.02
16.0 22 3.60 2.65 0.74 3.44 2.58 0.82 3.28 2.51 0.89 3.36 2.54 0.91 3.26 2.50 0.95 3.10 2.43 1.02
18.0 25 3.75 2.80 0.75 3.59 2.73 0.82 3.44 2.67 0.89 3.52 2.70 0.92 3.42 2.66 0.96 3.26 2.59 1.03
19.0 27 3.83 2.97 0.75 3.67 2.90 0.82 3.51 2.84 0.89 3.60 2.88 0.92 3.50 2.84 0.96 3.34 2.77 1.03
22.0 30 4.06 2.87 0.76 3.90 2.81 0.83 3.75 2.76 0.90 3.84 2.79 0.92 3.74 2.76 0.97 3.58 2.70 1.04
24.0 32 4.21 2.80 0.76 4.06 2.75 0.83 3.90 2.70 0.90 4.00 2.73 0.93 3.90 2.70 0.97 3.74 2.65 1.04

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D101504

Split Type Air Conditioners FTKC-Q Series 15


Capacity Tables EDID041611

FTKC50QVM4 + RKC50QVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 16.7
BF 0.08

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.11 4.07 1.05 4.88 3.96 1.15 4.65 3.85 1.26 4.75 3.89 1.29 4.60 3.82 1.35 4.36 3.71 1.45
16.0 22 5.34 4.00 1.06 5.11 3.89 1.16 4.88 3.79 1.26 4.99 3.84 1.30 4.84 3.77 1.36 4.60 3.67 1.46
18.0 25 5.57 4.23 1.07 5.34 4.13 1.17 5.11 4.04 1.27 5.23 4.08 1.30 5.08 4.02 1.36 4.84 3.93 1.46
19.0 27 5.69 4.50 1.07 5.45 4.40 1.17 5.22 4.31 1.27 5.35 4.36 1.30 5.20 4.30 1.37 4.96 4.21 1.47
22.0 30 6.03 4.35 1.08 5.80 4.27 1.18 5.57 4.19 1.28 5.70 4.23 1.31 5.56 4.18 1.37 5.32 4.10 1.47
24.0 32 6.26 4.25 1.08 6.03 4.17 1.18 5.80 4.10 1.29 5.94 4.15 1.32 5.80 4.10 1.38 5.56 4.02 1.48

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D101268

FTKC60QVM4 + RKC60QVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 16.7
BF 0.08

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.90 4.45 1.34 5.63 4.32 1.47 5.36 4.19 1.60 5.48 4.24 1.64 5.31 4.16 1.72 5.03 4.03 1.85
16.0 22 6.16 4.37 1.35 5.90 4.25 1.48 5.63 4.13 1.61 5.75 4.18 1.65 5.59 4.11 1.73 5.31 3.98 1.86
18.0 25 6.43 4.59 1.36 6.16 4.48 1.49 5.89 4.36 1.62 6.03 4.42 1.66 5.86 4.35 1.74 5.58 4.23 1.86
19.0 27 6.56 4.85 1.36 6.29 4.74 1.49 6.03 4.63 1.62 6.17 4.69 1.66 6.00 4.62 1.74 5.72 4.51 1.87
22.0 30 6.96 4.69 1.37 6.69 4.59 1.50 6.42 4.49 1.63 6.58 4.55 1.67 6.41 4.49 1.75 6.14 4.39 1.88
24.0 32 7.23 4.57 1.38 6.96 4.48 1.51 6.69 4.39 1.64 6.86 4.44 1.68 6.69 4.39 1.76 6.41 4.30 1.89

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D101270A

16 Split Type Air Conditioners FTKC-Q Series


EDID041611 Capacity Tables

FTKC71QVM4 + RKC71QVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 17.3
BF 0.11

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 6.02 4.51 1.82 6.02 4.51 2.00 6.02 4.51 2.18 6.02 4.51 2.23 6.02 4.51 2.34 4.46 3.76 2.30
16.0 22 7.29 4.92 1.84 6.98 4.76 2.01 6.66 4.61 2.19 6.81 4.68 2.24 6.61 4.59 2.35 4.69 3.71 2.30
18.0 25 7.61 5.12 1.85 7.29 4.98 2.02 6.97 4.84 2.20 7.13 4.91 2.25 6.94 4.82 2.36 4.91 3.96 2.30
19.0 27 7.76 5.38 1.85 7.45 5.24 2.03 7.13 5.10 2.20 7.30 5.17 2.26 7.10 5.09 2.37 5.02 4.24 2.30
22.0 30 8.24 5.17 1.87 7.92 5.05 2.04 7.60 4.93 2.22 7.79 5.00 2.28 7.59 4.93 2.38 5.35 4.12 2.30
24.0 32 8.55 5.03 1.88 8.23 4.92 2.05 7.92 4.81 2.23 8.12 4.88 2.29 7.92 4.81 2.39 5.57 4.03 2.30

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D101272A

Split Type Air Conditioners FTKC-Q Series 17


Capacity Tables EDID041611

7.2 Capacity Correction Factor by the Length of Refrigerant Piping (Reference)


The cooling capacity of the unit has to be corrected in accordance with the length of refrigerant piping —
the distance between the indoor unit and the outdoor unit.

7.2.1 25/35 Class


(R-32)
(%)
100
Capacity correction factor

90

Range of the
refrigerant
80 additional
charge

5 10 15 (m)

Piping length

7.2.2 50/60 Class


(R-32)
(%)
100
Capacity correction factor

90

80
Range of the refrigerant additional charge

5 10 15 20 25 30 (m)

Piping length

7.2.3 71 Class
(R-32)
(%)
100
Capacity correction factor

90

80
Range of the refrigerant additional charge

5 10 15 20 25 30 (m)

Piping length

Note: The graphs show the factor when additional refrigerant of the proper quantity is charged.

18 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Limit

8. Operation Limit
RKC25/35/50/60/71QVM4

50

46

40

Outdoor temp. (˚CDB)

Continuous operation

Pull-down period
30

20
19.4

10 14 20 23 28 30
Indoor temp. (˚CWB)
Notes:
The graph is based
on the following conditions.
• Equivalent piping length 7.5m
• Level difference 0m
• Airflow rate High

4D073983K

Split Type Air Conditioners FTKC-Q Series 19


Sound Level EDID041611

9. Sound Level
9.1 Measuring Location

Indoor Unit Outdoor Unit

1m 1m

0.8 m
MICROPHONE

MICROPHONE

Notes: 1. Operation sound is measured in an anechoic chamber.


2. The data are based on the conditions shown in the table below.

Cooling Piping Length


Indoor ; 27°CDB / 19°CWB 5m
Outdoor ; 35°CDB

9.2 Indoor Unit


FTKC25QVM4 FTKC35QVM4

70 OVER ALL ( dB ) 70 OVER ALL ( dB )


NC-70 NC-70

50/60Hz 50/60Hz 50/60Hz 50/60Hz


OCTAVE BAND SOUND PRESSURE LEVEL

OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V 60 SCALE 220-240/220-230V 220-240/220-230V


NC-60 (H) (L) NC-60 (H) (L)
A 38 25 A 39 26
50 ( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz POWER SOURCE 220-240/220-230V 50/60Hz
40 40
NC-40 JIS STANDARD NC-40 JIS STANDARD
STANDARD EXTERNAL STATIC PRESSURE STANDARD EXTERNAL STATIC PRESSURE
50/60Hz 220-240/220-230V (H) 50/60Hz 220-240/220-230V (H)
30 30
NC-30 50/60Hz 220-240/220-230V (L) NC-30 50/60Hz 220-240/220-230V (L)

20 20 NC-20
APPROXIMATE NC-20 APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D101498 63 125 250 500 1000 2000 4000 8000 4D101500
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

FTKC50QVM4 FTKC60QVM4

70 70
NC-70 OVER ALL ( dB ) OVER ALL ( dB )
NC-70
50/60Hz 50/60Hz 50/60Hz 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL
OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V 60 SCALE 220-240/220-230V 220-240/220-230V


(H) (L) NC-60 (H) (L)
NC-60
A 44 35 A 45 36
( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

50
dB(0dB=0.0002µ bar)

NC-50 NC-50 OPERATING CONDITIONS


OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz POWER SOURCE 220-240/220-230V 50/60Hz
40 40
JIS STANDARD NC-40 JIS STANDARD
NC-40
220-240/220-230V 50/60Hz (H) 220-240/220-230V 50/60Hz (H)
30 220-240/220-230V 50/60Hz (L) 30 220-240/220-230V 50/60Hz (L)
NC-30 NC-30
Cooling Cooling

20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D101274 63 125 250 500 1000 2000 4000 8000 4D101277
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

20 Split Type Air Conditioners FTKC-Q Series


EDID041611 Sound Level

FTKC71QVM4

70 OVER ALL ( dB )
NC-70

50/60Hz 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V


NC-60 (H) (L)
A 46 37
50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz
40
NC-40 JIS STANDARD
220-240/220-230V 50/60Hz (H)
30 220-240/220-230V 50/60Hz (L)
NC-30
Cooling

20
APPROXIMATE
THRESHOLD HEARING NC-20
FOR CONTINUOUS
NOISE
63 125 250 500 1000 2000 4000 8000 4D101279
OCTAVE BAND CENTER FREQUENCY (Hz)

9.3 Outdoor Unit


RKC25QVM4 RKC35QVM4

COOLING COOLING
70 OVER ALL ( dB ) 70 OVER ALL ( dB )
NC-70 NC-70

50/60Hz 50/60Hz 50/60Hz 50/60Hz


OCTAVE BAND SOUND PRESSURE LEVEL

OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V 60 SCALE 220-240/220-230V 220-240/220-230V


NC-60 (H) (L) NC-60 (H) (L)
A 47 44 A 49 45
50 ( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz (H) POWER SOURCE 220-240/220-230V 50/60Hz (H)
40 40
NC-40 JIS STANDARD (JIS9612) NC-40 JIS STANDARD (JIS9612)
220-240/220-230V 50/60Hz (H) 220-240/220-230V 50/60Hz (H)
30 220-240/220-230V 50/60Hz (L) 30 220-240/220-230V 50/60Hz (L)
NC-30 NC-30

20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D101508B 63 125 250 500 1000 2000 4000 8000 4D101510A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

RKC50QVM4 RKC60QVM4

COOLING COOLING
70 OVER ALL ( dB ) 70 OVER ALL ( dB )
NC-70 NC-70

50/60Hz 50/60Hz 50/60Hz 50/60Hz


OCTAVE BAND SOUND PRESSURE LEVEL

OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V 60 SCALE 220-240/220-230V 220-240/220-230V


NC-60 (H) (L) NC-60 (H) (L)
A 49 43 A 50 43
50 ( B.G.N IS ALREADY RECTIFIED ) 50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz (H) POWER SOURCE 220-240/220-230V 50/60Hz (H)
40 40
NC-40 JIS STANDARD (JIS9612) NC-40 JIS STANDARD (JIS9612)
220-240/220-230V 50/60Hz (H) 220-240/220-230V 50/60Hz (H)
30 220-240/220-230V 50/60Hz (L) 30 220-240/220-230V 50/60Hz (L)
NC-30 NC-30

20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D101261A 63 125 250 500 1000 2000 4000 8000 4D101263A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)

RKC71QVM4

COOLING
70 OVER ALL ( dB )
NC-70

50/60Hz 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL

60 SCALE 220-240/220-230V 220-240/220-230V


NC-60 (H) (L)
A 51 46
50 ( B.G.N IS ALREADY RECTIFIED )
dB(0dB=0.0002µ bar)

NC-50 OPERATING CONDITIONS


POWER SOURCE 220-240/220-230V 50/60Hz (H)
40
NC-40 JIS STANDARD (JIS9612)
220-240/220-230V 50/60Hz (H)
30 220-240/220-230V 50/60Hz (L)

NC-30

20
APPROXIMATE
THRESHOLD HEARING NC-20
FOR CONTINUOUS
NOISE
63 125 250 500 1000 2000 4000 8000 4D101265A
OCTAVE BAND CENTER FREQUENCY (Hz)

Split Type Air Conditioners FTKC-Q Series 21


Electric Characteristics EDID041611

10. Electric Characteristics

Power Supply Compressor OFM IFM


Indoor Unit Outdoor Unit
Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA
50 - 220 2.9 0.15 0.13
50 - 230 Max. 50 Hz, 264 V 2.8 0.14 0.13
Min. 50 Hz, 198 V
FTKC25QVM4 RKC25QVM4 50 - 240 7.5 15.0 72 2.7 26 0.13 19.5 0.12
60 - 220 Max. 60 Hz, 253 V 2.9 0.15 0.13
60 - 230 Min. 60 Hz, 198 V 2.8 0.14 0.13
50 - 220 4.2 0.15 0.19
Max. 50 Hz, 264 V
50 - 230 Min. 50 Hz, 198 V 4.1 0.14 0.19
FTKC35QVM4 RKC35QVM4 50 - 240 7.5 15.0 74 4.0 26 0.13 19.5 0.18
60 - 220 Max. 60 Hz, 253 V 4.2 0.15 0.19
60 - 230 Min. 60 Hz, 198 V 4.1 0.14 0.19
50 - 220 5.6 0.13 0.24
Max. 50 Hz, 264 V
50 - 230 Min. 50 Hz, 198 V 5.6 0.12 0.23
FTKC50QVM4 RKC50QVM4 50 - 240 10.0 15.0 63 5.5 38 0.11 46 0.22
60 - 220 Max. 60 Hz, 253 V 5.7 0.13 0.24
60 - 230 Min. 60 Hz, 198 V 5.6 0.12 0.23
50 - 220 7.6 0.13 0.24
Max. 50 Hz, 264 V
50 - 230 Min. 50 Hz, 198 V 7.5 0.12 0.23
FTKC60QVM4 RKC60QVM4 50 - 240 10.0 15.0 76 7.4 38 0.11 46 0.22
60 - 220 Max. 60 Hz, 253 V 7.6 0.13 0.24
60 - 230 Min. 60 Hz, 198 V 7.5 0.12 0.23
50 - 220 8.6 0.14 0.25
50 - 230 Max. 50 Hz, 264 V 8.5 0.13 0.24
Min. 50 Hz, 198 V
FTKC71QVM4 RKC71QVM4 50 - 240 10.0 15.0 82 8.4 38 0.12 46 0.23
60 - 220 Max. 60 Hz, 253 V 8.6 0.14 0.25
60 - 230 Min. 60 Hz, 198 V 8.5 0.13 0.24

Symbols: Notes:
MCA : Min. circuit amps (A) 1. RLA is based on the following conditions.
Indoor temp. 27°CDB / 19°CWB
MFA : Max. fuse amps (A) Outdoor temp. 35°CDB
RHz : Rated operating frequency (Hz) 2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
RLA : Rated load amps (A) 4. Instead of fuse, use circuit breaker.
OFM : Outdoor fan motor 5. Be sure to install an earth leak detector.
(This unit uses an inverter, which means that an earth leak
IFM : Indoor fan motor detector capable of handling high harmonics must be used in
W : Fan motor rated output (W) order to prevent malfunctioning of the earth leak detector.)
FLA : Full load amps (A)
3D101506A
3D101256B

22 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

11. Installation Manual


11.1 English
11.1.1 25/35 Class

Split Type Air Conditioners FTKC-Q Series 23


Installation Manual EDID041611

24 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 25


Installation Manual EDID041611

26 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 27


Installation Manual EDID041611

28 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 29


Installation Manual EDID041611

30 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 31


Installation Manual EDID041611

EN_3P409143-3B

32 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

11.1.2 50/60/71 Class

Split Type Air Conditioners FTKC-Q Series 33


Installation Manual EDID041611

34 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 35


Installation Manual EDID041611

36 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 37


Installation Manual EDID041611

38 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 39


Installation Manual EDID041611

40 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 41


Installation Manual EDID041611

EN_3P409143-7B

42 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

11.2 Indonesian
11.2.1 25/35 Class

Split Type Air Conditioners FTKC-Q Series 43


Installation Manual EDID041611

44 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 45


Installation Manual EDID041611

46 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 47


Installation Manual EDID041611

48 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 49


Installation Manual EDID041611

50 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 51


Installation Manual EDID041611

ID_3P409143-3B

52 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

11.2.2 50/60/71 Class

Split Type Air Conditioners FTKC-Q Series 53


Installation Manual EDID041611

54 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 55


Installation Manual EDID041611

56 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 57


Installation Manual EDID041611

58 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 59


Installation Manual EDID041611

60 Split Type Air Conditioners FTKC-Q Series


EDID041611 Installation Manual

Split Type Air Conditioners FTKC-Q Series 61


Installation Manual EDID041611

ID_3P409143-7B

62 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

12. Operation Manual


12.1 English
12.1.1 Safety Precautions

Split Type Air Conditioners FTKC-Q Series 63


Operation Manual EDID041611

64 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 65


Operation Manual EDID041611

12.1.2 25/35 Class

66 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 67


Operation Manual EDID041611

68 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 69


Operation Manual EDID041611

70 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 71


Operation Manual EDID041611

72 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 73


Operation Manual EDID041611

74 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 75


Operation Manual EDID041611

76 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 77


Operation Manual EDID041611

78 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 79


Operation Manual EDID041611

80 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 81


Operation Manual EDID041611

82 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 83


Operation Manual EDID041611

84 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 85


Operation Manual EDID041611

86 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 87


Operation Manual EDID041611

88 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

EN_3P413769-3G

Split Type Air Conditioners FTKC-Q Series 89


Operation Manual EDID041611

12.1.3 50/60/71 Class

90 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 91


Operation Manual EDID041611

92 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 93


Operation Manual EDID041611

94 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 95


Operation Manual EDID041611

96 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 97


Operation Manual EDID041611

98 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 99


Operation Manual EDID041611

100 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 101


Operation Manual EDID041611

102 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 103


Operation Manual EDID041611

104 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 105


Operation Manual EDID041611

106 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 107


Operation Manual EDID041611

108 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 109


Operation Manual EDID041611

110 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 111


Operation Manual EDID041611

112 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

EN_3P413769-7D

Split Type Air Conditioners FTKC-Q Series 113


Operation Manual EDID041611

12.2 Indonesian
12.2.1 Safety Precautions

114 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 115


Operation Manual EDID041611

116 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

12.2.2 25/35 Class

Split Type Air Conditioners FTKC-Q Series 117


Operation Manual EDID041611

118 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 119


Operation Manual EDID041611

120 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 121


Operation Manual EDID041611

122 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 123


Operation Manual EDID041611

124 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 125


Operation Manual EDID041611

126 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 127


Operation Manual EDID041611

128 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 129


Operation Manual EDID041611

130 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 131


Operation Manual EDID041611

132 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 133


Operation Manual EDID041611

134 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 135


Operation Manual EDID041611

136 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 137


Operation Manual EDID041611

138 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 139


Operation Manual EDID041611

ID_3P413769-3G

140 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

12.2.3 50/60/71 Class

Split Type Air Conditioners FTKC-Q Series 141


Operation Manual EDID041611

142 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 143


Operation Manual EDID041611

144 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 145


Operation Manual EDID041611

146 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 147


Operation Manual EDID041611

148 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 149


Operation Manual EDID041611

150 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 151


Operation Manual EDID041611

152 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 153


Operation Manual EDID041611

154 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 155


Operation Manual EDID041611

156 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 157


Operation Manual EDID041611

158 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 159


Operation Manual EDID041611

160 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 161


Operation Manual EDID041611

162 Split Type Air Conditioners FTKC-Q Series


EDID041611 Operation Manual

Split Type Air Conditioners FTKC-Q Series 163


Operation Manual EDID041611

ID_3P413769-7D

164 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

13. Optional Accessories


13.1 Option List
13.1.1 Indoor Unit

Option Name 25/35 Class 50/60/71 Class


1 Wireless LAN connecting adaptor BRP072A42 ★1 BRP072A42 ★2
2 Remote control PC-board set KRP067A41 KRP980B2
3 Titanium apatite photocatalytic air-purifying filter (without frame) ★3 KAF970A46
4 Remote controller loss prevention with chain KKF910A4

Notes: ★1 Remote control PC-board set (KRP067A41) is also required for each indoor unit.
★2 Remote control PC-board set (KRP980B2) is also required for each indoor unit.
★3 Standard accessory

13.1.2 Outdoor Unit

Option Name 25/35 Class


1 Air direction adjustment grille KPW937E4

Split Type Air Conditioners FTKC-Q Series 165


Optional Accessories EDID041611

13.2 <BRP072A42> Wireless LAN Connecting Adaptor


13.2.1 English

166 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

Split Type Air Conditioners FTKC-Q Series 167


Optional Accessories EDID041611

168 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

3P381857-1B

Split Type Air Conditioners FTKC-Q Series 169


Optional Accessories EDID041611

13.2.2 Indonesian

170 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

Split Type Air Conditioners FTKC-Q Series 171


Optional Accessories EDID041611

172 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

3P381857-4B

Split Type Air Conditioners FTKC-Q Series 173


Optional Accessories EDID041611

13.3 <KRP067A41> Remote Control PC-Board Set

174 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

Split Type Air Conditioners FTKC-Q Series 175


Optional Accessories EDID041611

176 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

1P398933-1

Split Type Air Conditioners FTKC-Q Series 177


Optional Accessories EDID041611

13.4 <KRP980B2> Remote Control PC-Board Set

178 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

Split Type Air Conditioners FTKC-Q Series 179


Optional Accessories EDID041611

180 Split Type Air Conditioners FTKC-Q Series


EDID041611 Optional Accessories

3P363899-2B

Split Type Air Conditioners FTKC-Q Series 181


Optional Accessories EDID041611

13.5 <KPW937E4> Air Direction Adjustment Grille

2P286387-1C

182 Split Type Air Conditioners FTKC-Q Series


Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

Specifications, designs and other content appearing in this brochure are current as of March 2016 but subject to change without notice.

c All rights reserved