Hot- Swappable

MODULARRECTIFIER SYSTEM

BWT220/24-180AS Rectifier system


Feature
 Wide operating range of AC input voltage: 90~290Vac

 current/voltage switching tech with high efficiency ≥93%

 Perfect battery management, battery temperature

 Multiple communication ports, easy for networking and remote

management.ModbusRS485 、TCP/IP 、YDN23 (YD/T 1363) protocol

 Temperature compensation, LVLD and LVBD protection,

 Automatic battery test function, cycle test, quick test

 Supports power system &module sleep, efficiency mixing, energy

saving

 Support real-time detection of the operating status of the power

system

 Support alarm real-time detection and reporting

 Hot-swap able

 Input over/under voltage protection

 Output over voltage protection

 Output over current protection

 Output short circuit protection

 Auto current sharing, parallel operation Description


Modular rectifier System is a modular Extra-able power system

Application based on building blocks for both 19 inch system solutions.

It is consist of Rectifier module & Control Monitor & 19’’framework.


 Telecom station/base/ Cabinet Equipment
This rectifier system 90~290 Vac Single phase AC supply voltages
 SCADA Networks and Data Room
into stable nominal 24VDC voltage adjustable to the needs of the
 Transmission equipment
application.
 Radio base station/cell sites
All versions provide options for alarming and battery temperature
 Railway & metro
probes.
 Direct-current emergency power units in power stations and
chemical plants
Technical specifications 24Vdc 5.4KW
Output power Vs input voltage @ 45°C
GENERALLY DETAILS RECTIFIER MODULE ------BR241800
Technical Pout/W
AC Input Input Single phase 220Vac 50hz
BR241800*3.....................Rectifier module (I/P 220Vac,
50HZ,Range:45Hz~66Hz
100%
O/P: 24Vdc ,2U); Frequency

M30.1.2V *1...….....................Monitor module (I/P Voltage Range 90V~290VAC

24Vdc ,2U Size for optional); Rated current(A) 60A 50%


SRM-19*1…….................2U 19" Inch hot-swap Max Output Current 0~66A
chassis; Rated power(W) 1800W@Vout put>24V Vin/Vac
Classification …………………………………………IP20; 90 170±5 175±5 300
Rated voltage(V) 24V
Safety…………………… GB4943-2001& IEC 60950-1; Equ- Voltage(V) 28.2V(21-29Vdc adjustable);
Output voltage Vs output current @ 45°C
EMI ……………………………………… EN 55032:2015; Float voltage(V) 26.7V(21-29Vdc adjustable);
DC
………………………………………EN 55035:2017; Output Accuracy(V) ≤0.6% Vdc
output
…………………………………EN61000-3-2:2014;
Output ripple voltage ≤200mV<0-20mHZ>
30 29
…………………………………EN61000-3-3:2013;
0.99@220VAC/60A,
PF
………………………………… EN55022, CLASS A; 28
≥0.98@220VAC/30A; 26.7
………………………………… EN300386,CLASS ;
Leakage current ≤1.5mA 25
ESD……………………GB17626.2-1998/IEC61000-4-2; 21.6
≥93.2%@220VAc Peaking
EFT……………………GB17626.4-1998/IEC61000-4-4; Efficiency 20
≥92.0%@220Vac 100% Load;
SURGE………………GB17626.5-1998/IEC61000-4-5;
Input/output voltage、Frequency、output
DIP…………………GB17626.11-1998/IEC61000-4-11; LCD display 0 10 30 40 60 66 A
current、Environment、Rate
Conducted Immunity………………… IEC61000-4-6; Indicator
City power、Output、Under voltage、
Radiated Immunity ……………………IEC61000-4-3; Power status Output power Vs ambient temperature
overload voltage
Environment ………………ETSI EN 300 019-2 RoHS; W
±5% from true average current between
Current Sharing
modules; 100%
Load regulation 2%

Line regulation 1%

Dimension 220X103X88mm (D*W*H)


50%

-40 55 65 75 ℃
MONIOTRO CONTROL ---M30.1.2V SERIAL

Features:
 Monitors the power system operating status in real time ;

 Detects and reports alarms in real time

 Supports multiple remote management modes.

 Supports flexible rectifier management.

 Supports effective energy conservation management.

 Supports comprehensive battery management.

 Supports intelligent temperature control management.

 Supports flexible and programmable logic control. Technical

 Supports detailed data records and performance statistics. Voltage (V) 20~30Vdc

DC Input Current(A) ≤0.5A

Power(W) Less than 20W


DISTRIBUTION Rs485 Available (Modbus Protocol)

TCP/IP Available

AC Distribution ……L+N+PE/220VAc Rail -mount Terminal SNMP Optional

block Max135A; AC Power Failure,AC Input Fault ,DC Output Fault ,Battery Over Voltage,DI Dry contact,Rectifier

Input Surge …………………… Optional; Communica Alarm Dry module output Over Voltage,Rectifier module output Under Voltage,Rectifier Module Fault,Rectifier

Input MCB ……………………………Optional; tion Contact*6 Module Communication Fault,Rectifier Module Current Limiting,Rectifier module current non-equalize,

DC Distribution ……………3*135A DC loading Rail -mount Interface Rectifier module Protection,Battery Power off ,Load Fuse,Battery Fuse,Battery Connect Fail。

Terminal block; 1* Battery Temp,1*Ambient Temp,1*Air Conditioning ,. 1*Smoke Alarm.,1*Flooding Alarm.,1*Access

1*135A Battery charger Rail -mount Terminal block; Signal Input Alarm.,1*Surge arrest,1* Fan,1*generator , Battery Current Detection*1,AC Power Voltage

Load MCB ……………………………Optional; Detection*1,Fuse Signal Input *1Mid-Point Voltage Detection *1

Battery MCB ……………………………Optional; Baud Rate 9600 Bit/s

Storage Historical Alarm


Up to 1000 Units
Capacity Records
ORTHER SPECIFICATIOS DEFAULT SETTING

Low mains shutdown Parameters Setting range Default value


High temperature shutdown
Battery capacity 20Ah-300Ah 80Ah
Rectifier Failure
Battery H-temp.Protection Voltage 20~30V 26.7V
Alarms: Over voltage shutdown on output

Fan failure, one or two fans. Float Switch to Equalizing Charging Coefficient 0.05-0.25 0.06 C10

Low voltage alarm Equalizing Switch to Float charging Coefficient 0.01-0.25 0.04C10

CAN bus failure Charging current limit 0.05-0.5C 0.1C

Charging over current 0.05-0.5C 0.25C


Low temperature shutdown
Battery Com Coeff 0-500 mV 50mV
Remote battery current limit activated
Warnings:
Input voltage out of range,Over voltage Battery test termination voltage 20~30V 30V

Loss of CAN communication with control Note:

3500Vdc/10mA//1min Input - output 1. The battery protection voltage should be set according to the requirements of the battery manufacturer

Isolation 3500Vdc/10mA//1min Input-chassis 2. If the user configures iron lithium battery, the relevant charging parameters should be set according to the

750Vdc/10mA//1min Output - chassis requirements of the battery manufacturers

3. For more details about the Common Parameters of rectifier system, please refer to the Factory Testing
MTBF > 10,0000 hours (Tambient : 25°C)
reports.
Operating
temp -40 to +55°C (-40 to +131°F)

Storage temp -40 to +70°C (-40 to +158°F) Model.No Rectifier module Output Capacity
BWT220Vac/24Vdc-30AS BR24900*1 900W
Acoustic
Noise < 55dBA at nominal input and full load(Tambient < 30°C)
BWT220Vac/24Vdc-60AS BR241800*1 1800W
Altitude <2000M
BWT220Vac/24Vdc-80AS BR241200*2 2400W
Cooling fans (front to back airflow)
BWT220Vac/24Vdc-100AS BR241500*2 3000W
Fan Speed Temperature and current regulated
BWT220Vac/24Vdc-120AS BR241800*2 3600W
Humidity Operating: 5% to 95% RH non-condensing BWT220Vac/24Vdc-240AS BR241800*4 7200W
BWT220Vac/24Vdc-600AS BR241800*10 18KW
Application for other type, please advise to us
Contact Bwitt for data sheets and characterization details. Due to product

development, specifications are subject to change without prior notice.

Thomas@bwitt.com.cn WWW.BWITT.COM.CN
Add:Bldg 8, Sunshine Industry Park, Xili town,Nanshan , Shenzhen , Guangdong, China
Tel:+86 755 21007420 Fax:+86 755 2983220786 Phone :8613823220786