www.wattenbarger.com
QUAIL PARK AT BROWNS POINT
BROWNS POINT TOWN CENTER - BUILDING 'A'
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
COVER
BUILDING PERMIT SET
CENTER
PROJECT DIRECTORY: ASSOCIATED PERMITS DEFERRED SUBMITTALS SPECIAL INSPECTIONS PROPOSAL SUMMARY
STRUCTURAL DEFERRED SUBMITTALS: • STRUCTURAL STEEL (1705.2.1) PROJECT DESCRIPTION
OWNER PRECONSTRUCTION CONSULT. INTERIOR DESIGNER PREAPPLICATION: 915957
DESIGN BUILT COMPONENTS
NAVIGATOR DEVELOPMENT GROUP KTM DEVELOPMENT SERVICES, LLC SECHRIST DESIGN ASSOCIATES, INC. INCLUDED BUT NO LIMITED TO: • CONCRETE CONSTRUCTION (1705.3) CONSTRUCT A 6-STORY, 134,204 GROSS SQUARE FOOT
SITE DEVELOPMENT: 928219
146 CANAL ST. SUITE 220, 12515 WILLOWS ROAD NE, SUITE 125 5819 6TH AVE. SOUTH SEWER PRETREATMENT BLDG A: 926127 - WELDING OF REINFORCING BARS ASSISTED LIVING AND MEMORY CARE COMMUNITY. THE
SEATTLE, WA 98103 KIRKLAND, WA. 98024 SEATTLE, WA 98108 • MECHANICAL EQUIPMENT ANCHORAGE FOR EQUIPMENT > 400LBS - MATERIALS TESTING
SEWER GREASE INTERCEPTOR: 926286
• SHOP DRAWINGS FOR POST-TENSIONED CONCRETE BUILDING WILL BE 3 STORIES OF TYPE V-A
PHONE: (206) 441-1770 PHONE: (425) 885-1983 PHONE: (206) 723-1147 COMMERCIAL WATER SYSTEMS: 919929 - REINFORCMENT INCLUDING PRESTRESSING TENDONS.
CONTACT: DENIS BRYANT EMAIL: TOMV@KTMCC.NET CONTACT: MELINDA SECHRIST • PRE-FABRICATED METAL PLATE CONNECTED WOOD TRUSSES - REINFORCING BAR WELDING
CONSTRUCTION OVER A 3 STORY PODIUM OF TYPE I-A
FIRE SPRINKLER UNDERGROUND: TBD CONSTRUCTION. THE BUILDING CONTAINS 118 UNITS (79
ERIN TIGHE CONTACT: TOM VASILATOS • CONTINUOUS ROD HOLD DOWN SYSTEM - ANCHORS CAST IN CONCRETE
DRIVEWAY APPROACH: 928220 • METAL STAIRS DWELLING UNITS AND 39 SLEEPING UNITS ACROSS
TRAFFIC IMPACT ANALYSIS: 921318 - ANCHORS POST-INSTALLED IN HARDENED CONC. MEMBERS
• ELEVATOR MACHINE BEAMS - DESIGN MIX STUDIO, 1 AND 2 BEDROOM PLANS) ALONG WITH
KITCHEN DESIGNER TRAFFIC DEVIATION REQUEST 932209
OWNER STRUCTURAL ENGINEER SEPA 930604 - FABRICATION OF SPECIMINS FOR STRENGTH TEST, SLUMP ASSOCIATED COMMON, SUPPORT, AND ADMINISTRATIVE
CLARK FOOD SERVICE EQUIP. NPDES 26258 AND AIR CONTENT TESTS, DETERMINATION OF CONC. TEMP. SPACES AS WELL AS PARKING ON THE BASEMENT
47 NORTH DEVELOPMENT STRUCTURAL FORTE, INC.
2207 OLD PHILADELPHIA PIKE - CONCRETE AND SHOTCRETE APPLICATION TECHNIQUES. LEVEL.
565 13TH AVE. 7307 N DIVISION STREET, SUITE #304
LANCASTER, PA 17602 SHORING TBD - PRESTRESSED CONCRETE.
SEATTLE, WA 98122 SPOKANE, WA. 98208
PHONE: (717) 392-7363 x325 STORMWATER VAULT TBD - CONCRETE STRENGTH PRIOR TO STRESSING
PHONE: (206) 931-2535 PHONE: (509) 624-3224
CONTACT: ANTON KATSCH NON-STRUCTURAL: - FORMWORK.
CONTACT: MATT HERRON CONTACT: BRIAN MATZ
COMMERCIAL MECH. - (HVAC) PERMIT TBD • ACCESSIBLE SIGNAGE
COMMERCIAL MECH. - FIRE SPRINKLER PERMIT TBD • GUARDS • WOOD CONSTRUCTION (1705.5)
WATTENBARGER ARCHITECTURE, INC. ABOSSEIN ENGINEERING, LLC T.E.N.W. SIGN PERMIT TBD • SOILS (1705.6)
11000 N.E. 33RD PL., SUITE #102 18465 NE 68TH ST., P.O. BOX 65254 - MATERIALS BELOW SHALLOW FOUNDATIONS
- EXCAVATION DEPTH PROJECT ADDRESS: 1008 TOWN CENTER NE
BELLEVUE, WA. 98004 REDMOND, WA 98052 SEATTLE, WA 98155
PHONE: (425) 453-0606 PHONE: (425) 462-9441 PHONE: (206) 361-7333 X101 - CLASSIFICATION AND TESTING OF COMPACTED FILL TACOMA, WA 98422
CONTACT: TRAVIS MCDANOLD, AIA CONTACT: GARY WOMACK CONTACT: MICHAEL READ - MATERIALS, DENSITY AND LFIT THICKNESS DURING
JAMES BROWN, AIA PLACEMENT OF COMPACTED FILL PARCEL TAX ID NUMBER: 7575000031
- SUBRADE AND SITE PREPARATION PRIOR TO PLACEMENT OF FILL
SHT. ISSUE SHT. ISSUE SHT. ISSUE SHT. ISSUE SHT. ISSUE
NO. SHEET NAME DATE NO. SHEET NAME DATE NO. SHEET NAME DATE NO. SHEET NAME DATE NO. SHEET NAME DATE
00 GENERAL A222 SLAB EDGE PLAN - BASEMENT 01/22/21 A816 WINDOW SCHEDULE 01/22/21 M5.0B 3RD FLOOR PLAN HVAC - SOUTH 12/18/19 E4.5A POWER - FIFTH FLOOR 09/10/20
BELLEVUE, WA 98004
G003 BUILDING CODE ANALYSIS 01/22/21 A301 UNIT PLANS 01/22/21 A903 FOUNDATION DETAILS 01/22/21 M7.0B 5TH FLOOR PLAN HVAC - SOUTH 12/18/19 E6.1 ENLARGED UNIT PLANS 09/10/20
G004 BUILDING CODE ANALYSIS 01/22/21 A302 UNIT PLANS 01/22/21 A910 EXTERIOR SOFFIT & ROOF DETAILS 01/22/21 M8.0A ROOF PLAN HVAC - NORTH 12/18/19 E6.2 ENLARGED UNIT PLANS 09/10/20
G005 BUILDING CODE ANALYSIS 01/22/21 A303 UNIT PLANS 01/22/21 A911 WINDOW FLASHING SEQUENCE 01/22/21 M8.0B ROOF PLAN HVAC - SOUTH 12/18/19 E6.3 ENLARGED UNIT PLANS 09/10/20
G006 ZONING CODE COMPLIANCE NARRATIVE 01/22/21 A304 UNIT PLANS 01/22/21 A912 EXTERIOR WALL DETAILS 01/22/21 M9.0 ENLARGED DWELLING UNITS HVAC 12/18/19 E6.4 ENLARGED UNIT PLANS 09/10/20
G007 ZONING CODE COMLIANCE DIAGRAMS 01/22/21 A305 UNIT PLANS 01/22/21 A913 CLADDING DETAILS 01/22/21 M10.0 ENLARGED DWELLING UNITS HVAC 12/18/19 E6.5 ENLARGED UNIT PLANS 09/10/20
G008 ZONING CODE COMPLIANCE DIAGRAMS 01/22/21 A306 UNIT PLANS 01/22/21 A914 CLADDING DETAILS 01/22/21 M11.0 ENLARGED DWELLING UNITS HVAC 12/18/19 E6.6 ENLARGED UNIT PLANS 09/10/20
G009 OCCUPANCY & EXITING - BASEMENT 01/22/21 A307 ENLARGED FLOOR PLANS 01/22/21 A915 DECK DETAILS 01/22/21 M12.0 MECHANICAL DETAILS 12/18/19 E6.7 ENLARGED UNIT PLANS 09/10/20
G010 LIFE SAFETY DIAGRAM - BASEMENT 01/22/21 A308 ENLARGED FLOOR PLANS 01/22/21 A920 INTERIOR WALL & FLOOR DETAILS 01/22/21 M12.1 MECHANICAL DETAILS 12/18/19 E6.8 ENLARGED UNIT PLANS 09/10/20
G011 OCCUPANCY & EXITING - FIRST FLOOR 01/22/21 A401 BASEMENT REFLECTED CEILING PLAN - N 01/22/21 A930 ROOF DETAILS 01/22/21 M13.0 SPECIFICATIONS 12/18/19 E6.9 ENLARGED UNIT PLANS 09/10/20
G012 LIFE SAFETY DIAGRAM FIRST FLOOR 01/22/21 A402 BASEMENT REFLECTED CEILING PLAN - S 01/22/21 A950 DOOR DETAILS 01/22/21 E6.10 ENLARGED UNIT PLANS 09/10/20
G013 OCCUPANCY & EXITING - SECOND FLOOR 01/22/21 A403 FIRST FLOOR REFLECTED CEILING PLAN - N 01/22/21 A951 DOOR DETAILS 01/22/21 06 PLUMBING E6.11 ENLARGED POWER PLAN - KITCHEN 09/10/20
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
G014 LIFE SAFETY DIAGRAM SECOND FLOOR 01/22/21 A404 FIRST FLOOR REFLECTED CEILING PLAN - S 01/22/21 A952 DOOR DETAILS 01/22/21 P1.0 LEGEND, SCHEDULES, NOTES & DETAILS 12/18/19 E7.1 ENERGY CODE FORMS - LIGHTING 09/10/20
G015 OCCUPANCY & EXITING - THIRD FLOOR 01/22/21 A405 SECOND FLOOR REFLECTED CEILING PLAN - N 01/22/21 A960 WINDOW DETAILS 01/22/21 P2.0A FOUNDATION PLAN - PLUMBING - NORTH 12/18/19 E7.2 ENERGY CODE FORMS - LIGHTING 09/10/20
G016 LIFE SAFETY DIAGRAM THIRD FLOOR 01/22/21 A406 SECOND FLOOR REFLECTED CEILING PLAN - S 01/22/21 A961 WINDOW DETAILS 01/22/21 P2.0B GROUND LEVEL PLAN - PLUMBING - SOUTH 12/18/19 E8.1 LIGHTING DETAILS 09/10/20
G017 OCCUPANCY & EXITING - FOURTH FLOOR 01/22/21 A407 THIRD FLOOR REFLECTED CEILING PLAN - N 01/22/21 A970 CEILING DETAILS 01/22/21 P2.1A GROUND LEVEL PLAN - PLUMBING - NORTH 12/18/19 E8.2 LIGHTING DETAILS 09/10/20
G018 LIFE SAFETY DIAGRAM FOURTH FLOOR 01/22/21 A408 THIRD FLOOR REFLECTED CEILING PLAN - S 01/22/21 A980 MISC. DETAILS 01/22/21 P2.1B GROUND LEVEL PLAN - PLUMBING - SOUTH 12/18/19 E8.3 SYSTEM RISER DIAGRAMS 09/10/20
G019 OCCUPANCY & EXITING - FIFTH FLOOR 01/22/21 A409 FOURTH FLOOR REFLECTED CEILING PLAN - N 01/22/21 A990 CASEWORK DETAILS 01/22/21 P3.0A 1ST FLOOR PLAN - PLUMBING - NORTH 12/18/19 E9.1 POWER RISER DIAGRAM 09/10/20
10635
G020 LIFE SAFETY DIAGRAM FIFTH FLOOR 01/22/21 A410 FOURTH FLOOR REFLECTED CEILING PLAN - S 01/22/21 P3.0B 1ST FLOOR PLAN - PLUMBING - SOUTH 12/18/19 E9.2 FAULT CURRENT CALCULATIONS 09/10/20
G021 AIR & THERMAL BARRIER 01/22/21 A411 FIFTH FLOOR REFLECTED CEILING PLAN - N 01/22/21 04 STRUCTURAL P4.0A 2ND FLOOR PLAN - PLUMBING - NORTH 12/18/19 E9.3 FAULT CURRENT CALCULATIONS 09/10/20
A412 FIFTH FLOOR REFLECTED CEILING PLAN - S 01/22/21 S101 GENERAL STRUCTURAL NOTES 08/17/20 P4.0B 2ND FLOOR PLAN - PLUMBING - SOUTH 12/18/19 E10.1 PANEL SCHEDULES 09/10/20
01 CIVIL A501 EXTERIOR ELEVATIONS 01/22/21 S102 SPECIAL INSPECTIONS & TYPICAL DETAILS 08/17/20 P5.0A 3RD FLOOR PLAN - PLUMBING - NORTH 12/18/19 E10.2 PANEL SCHEDULES 09/10/20
C0.00 COVER SHEET 02/06/20 A502 EXTERIOR ELEVATIONS 01/22/21 S103 POST TENSION TYPICAL DETAILS 08/17/20 P5.0B 3RD FLOOR PLAN - PLUMBING - SOUTH 12/18/19 E10.3 PANEL SCHEDULES 09/10/20 Revision Schedule
C1.00 DEMOLITION PLAN 02/06/20 A503 EXTERIOR ELEVATIONS 01/22/21 S104 TYPICAL DETAILS 08/17/20 P6.0A 4TH FLOOR PLAN - PLUMBING - NORTH 12/18/19 E10.4 PANEL SCHEDULES 09/10/20
# DESCRIPTION DATE
C2.00 OVERALL GRADING PLAN 02/06/20 A504 EXTERIOR ELEVATIONS 01/22/21 S201 FOUNDATION PLAN - N 08/17/20 P6.0B 4TH FLOOR PLAN - PLUMBING - SOUTH 12/18/19 E10.5 PANEL SCHEDULES 09/10/20
C2.01 GRADING ENLARGEMENT 02/06/20 A601 BUILDING SECTIONS 01/22/21 S202 FOUNDATION PLAN - S 08/17/20 P7.0A 5TH FLOOR PLAN - PLUMBING - NORTH 12/18/19
C2.02 GRADING ENLARGEMENT 02/06/20 A602 BUILDING SECTIONS 01/22/21 S203 FIRST FLOOR MILD REINFORCEMENT PLAN - N 08/17/20 P7.0B 5TH FLOOR PLAN - PLUMBING - SOUTH 12/18/19 08-KITCHEN
C2.03 GRADING ENLARGEMENT 02/06/20 A603 BUILDING SECTIONS 01/22/21 S204 FIRST FLOOR MILD REINFORCING PLAN - S 08/17/20 P8.0A 5TH FLOOR PLAN - PLUMBING - NORTH 12/18/19 QF-0.0 FOOD SERVICE COVER SHEET 09/10/20
C2.04 GRADING ENLARGEMENT 02/06/20 A605 WALL SECTIONS - EXTERIOR 01/22/21 S205 FIRST FLOOR P-T PLAN - N 08/17/20 P8.0B ROOF PLAN - PLUMBING - SOUTH 12/18/19 QF-1.1 STORAGE FLOOR PLAN - BASEMENT 09/10/20
C3.00 PAVING PLAN 02/06/20 A606 WALL SECTIONS - EXTERIOR 01/22/21 S206 FIRST FLOOR P-T PLAN - S 08/17/20 P9.0 WASTE & VENT RISER DIAGRAM 12/18/19 QF-1.2 MC KITCHEN PLAN - FIRST FLOOR 09/10/20
C4.00 STORM DRAINAGE PLAN 02/06/20 A608 WALL SECTIONS - INTERIOR 01/22/21 S207 SECOND FLOOR MILD REINFORCING PLAN - N 08/17/20 P9.1 WASTE & VENT RISER DIAGRAM 12/18/19 QF-1.3 BISTRO KITCHEN PLAN - SECOND FLOOR 09/10/20
C5.00 UTILITY PLAN 02/06/20 A609 ELEV. 1-ENLARGED PLANS & SECTIONS 01/22/21 S208 SECOND FLOOR MILD REINFORCING PLAN - S 08/17/20 P9.2 WASTE & VENT RISER DIAGRAM 12/18/19 QF-1.4 MAIN KITCHEN PLAN - FIFTH FLOOR 09/10/20
C6.00 SEWER COVER SHEET 02/06/20 A610 ELEV. 2 & 3-ENLARGED PLANS & SECTIONS 01/22/21 S209 SECOND FLOOR P-T PLAN - N 08/17/20 P9.3 WASTE & VENT RISER DIAGRAM 12/18/19 QF-2.1 ELEVATIONS - STORAGE BASEMENT 09/10/20
C6.01 SEWER PLAN AND PROFILE 02/06/20 A611 STAIR 1 & 2 - ENLARGED FLOOR PLANS & SECTIONS 01/22/21 S210 SECOND FLOOR P-T PLAN - S 08/17/20 P9.4 WASTE & VENT RISER DIAGRAM 12/18/19 QF-2.2 ELEVATIONS - MC KITCHEN 09/10/20
C7.00 OFFSITE COVER SHEET 02/06/20 A612 STAIR 3 - ENLARGED FLOOR PLANS & SECTIONS 01/22/21 S211 THIRD FLOOR MILD REINFORCING PLAN - N 08/17/20 P9.5 WASTE & VENT RISER DIAGRAM 12/18/19 QF-2.3 ELEVATIONS - BISTRO 09/10/20
C7.03 OFFSITE IMPROVEMENT PLAN 02/06/20 A613 TRASH CHUTE DETAILS 01/22/21 S212 THIRD FLOOR MILD REINFORCING PLAN - S 08/17/20 P9.6 WASTE & VENT RISER DIAGRAM 12/18/19 QF-2.4 ELEVATIONS - MAIN KITCHEN 09/10/20
A614 STAIR DETAILS 01/22/21 S213 THIRD FLOOR P-T PLAN - N 08/17/20 P9.7 WASTE & VENT RISER DIAGRAM 12/18/19 QF-2.5 ELEVATIONS - MAIN KITCHEN 09/10/20
SHEET INDEX
02 LANDSCAPE A615 ELEVATOR DETAILS 01/22/21 S214 THIRD FLOOR P-T PLAN - S 08/17/20 P10.0 DOMESTIC WATER RISER DIAGRAM 12/18/19 QF-3.1 ISOMETRICS - STORAGE BASEMENT 09/10/20
L1.0 BUILDING A SITE PLAN 07/10/20 A616 PORTE COCHERE 01/22/21 S215 THIRD FLOOR WALL PLAN - N 08/17/20 P10.1 DOMESTIC WATER RISER DIAGRAM 12/18/19 QF-3.2 ISOMETRICS - MC KITCHEN 09/10/20
L2.0 SITE DETAILS AND NOTES 07/10/20 A617 PORTE COCHERE 01/22/21 S216 THIRD FLOOR WALL PLAN - S 08/17/20 P10.2 DOMESTIC WATER RISER DIAGRAM 12/18/19 QF-3.3 ISOMETRICS - BISTRO 09/10/20
L3.0 BUILDING A PLANTING PLAN 07/10/20 A701 MOUNTING HEIGHTS - GENERAL 01/22/21 S217 FOURTH FLOOR FRAMING PLAN - N 08/17/20 P10.3 DOMESTIC WATER RISER DIAGRAM 12/18/19 QF-3.4 ISOMETRICS - MAIN KITCHEN 09/10/20
L4.0 PLANTING DETAILS AND NOTES 07/10/20 A702 INTERIOR ELEVATIONS- UNIT BATHROOMS 01/22/21 S218 FOURTH FLOOR FRAMING PLAN - S 08/17/20 P10.4 DOMESTIC WATER RISER DIAGRAM 12/18/19 QF-4.0 PLUMBING UTILITY SCHEDULE 09/10/20
L5.0 BUILDING A IRRIGATION PLAN 07/10/20 A703 INTERIOR ELEVATIONS- UNIT BATHROOMS 01/22/21 S219 FOURTH FLOOR WALL PLAN - N 08/17/20 P11.0 ENLARGED PLANS 12/18/19 QF-4.1 STORAGE PLUMBING ROUGH-INS 09/10/20
L6.0 IRRIGATION NOTES AND DETAILS 07/10/20 A704 INTERIOR ELEVATIONS- UNIT BATHROOMS 01/22/21 S220 FOURTH FLOOR WALL PLAN - S 08/17/20 P12.0 DETAILS 12/18/19 QF-4.2 MC KITCHEN PLUMBING ROUGH-INS 09/10/20
L6.1 IRRIGATION NOTES AND DETAILS 07/10/20 A705 INTERIOR ELEVATIONS- UNIT BATHROOMS 01/22/21 S221 FIFTH FLOOR FRAMING PLAN - N 08/17/20 P12.1 DETAILS 12/18/19 QF-4.3 BISTRO PLUMBING ROUGH-INS 09/10/20
A706 INTERIOR ELEVATIONS- UNIT BATHROOMS 01/22/21 S222 FIFTH FLOOR FRAMING PLAN - S 08/17/20 QF-4.4 MAIN KITCHEN PLUMBING ROUGH-INS 09/10/20
03 ARCHITECTURAL A707 INTERIOR ELEVATIONS- UNIT BATHROOMS 01/22/21 S223 FIFTH FLOOR WALL PLAN - N 08/17/20 07 ELECTRICAL QF-5.0 ELECTRIC UTILITY SCHEDULE 09/10/20
A101 ARCHITECTURAL SITE PLAN 01/22/21 A708 INTERIOR ELEVATIONS- COMMON AREA BATHROOMS 01/22/21 S224 FIFTH FLOOR WALL PLAN - S 08/17/20 E1.0 ELECTRICAL NOTES, SCHEDULES, LEGENDS 09/10/20 QF-5.1 STORAGE ELECTRICAL ROUGH-INS 09/10/20
A102 PARTIAL SITE PLAN - SOUTH 01/22/21 A709 INTERIOR ELEVATIONS- COMMON AREA BATHROOMS 01/22/21 S225 ROOF FRAMING PLAN - N 08/17/20 E2.0 ELECTRICAL SITE PLAN 09/10/20 QF-5.2 MC KITCHEN ELECTRICAL ROUGH-INS 09/10/20
A103 PARTIAL SITE PLAN - NORTH 01/22/21 A710 INTERIOR ELEVATIONS- UNIT KITCHENS 01/22/21 S226 ROOF FRAMING PLAN - S 08/17/20 E3.0A LIGHTING - GROUND FLOOR 09/10/20 QF-5.3 BISTRO ELECTRICAL ROUGH-INS 09/10/20
A201 OVERALL ARCHITECTURAL BUILDING PLANS - BASEMENT 01/22/21 A711 INTERIOR ELEVATIONS- UNIT KITCHENS 01/22/21 S301 FOUNDATION DETAILS 08/17/20 E3.0B LIGHTING - GROUND FLOOR 09/10/20 QF-5.4 MAIN KITCHEN ELECTRICAL ROUGH-INS 09/10/20
A202 OVERALL ARCHITECTURAL BUILDING PLANS - 1ST FLOOR 01/22/21 A712 INTERIOR ELEVATIONS- COMMON AREA 01/22/21 S302 CONCRETE COLUMNS 08/17/20 E3.1A LIGHTING - FIRST FLOOR 09/10/20 QF-6.1 STORAGE - SPECIAL CONDITIONS 09/10/20
A203 OVERALL ARCHITECTURAL BUILDING PLANS - 2ND FLOOR 01/22/21 A713 INTERIOR ELEVATIONS- COMMON AREA 01/22/21 S401 CONCRETE FRAMING DETAILS 08/17/20 E3.1B LIGHTING - FIRST FLOOR 09/10/20 QF-6.2 MC KITCHEN - SPECIAL CONDITIONS 09/10/20
A204 OVERALL ARCHITECTURAL BUILDING PLANS - 3RD FLOOR 01/22/21 A714 INTERIOR ELEVATIONS- COMMON AREA 01/22/21 S402 CONCRETE FRAMING DETAILS 08/17/20 E3.2A LIGHTING - SECOND FLOOR 09/10/20 QF-6.3 BISTRO - SPECIAL CONDITIONS 09/10/20
A205 OVERALL ARCHITECTURAL BUILDING PLANS - 4TH FLOOR 01/22/21 A715 INTERIOR ELEVATIONS- COMMON AREA 01/22/21 S501 WOOD FRAMING DETAILS 08/17/20 E3.2B LIGHTING - SECOND FLOOR 09/10/20 QF-6.4 MAIN KITCHEN - SPECIAL CONDITIONS 09/10/20
CENTER
A213 SECOND FLOOR PARTIAL PLAN - S 01/22/21 A807 FIRESTOPPING DETAILS 01/22/21 M1.3 GENERAL NOTES, SCHEDULES & LEGEND 12/18/19 E4.0B POWER - GROUND FLOOR 09/10/20 QF-8.5 HOOD SHOP DRAWINGS 09/10/20
A214 THIRD FLOOR PARTIAL PLAN - N 01/22/21 A808 FIRESTOPPING DETAILS 01/22/21 M1.4 GENERAL NOTES, SCHEDULES & LEGEND 12/18/19 E4.1A POWER - FIRST FLOOR 09/10/20 QF-8.6 HOOD SHOP DRAWINGS 09/10/20
A215 THIRD FLOOR PARTIAL PLAN - S 01/22/21 A809 FIRESTOPPING DETAILS 01/22/21 M2.0A BASEMENT FLOOR PLAN HVAC - NORTH 12/18/19 E4.1B POWER - FIRST FLOOR 09/10/20 QF-8.7 HOOD SHOP DRAWINGS 09/10/20
A216 FOURTH FLOOR PARTIAL PLAN - N 01/22/21 A810 FIRESTOPPING DETAILS 01/22/21 M2.0B BASEMENT FLOOR PLAN HVAC - SOUTH 12/18/19 E4.2A POWER - SECOND FLOOR 09/10/20 QF-8.8 HOOD SHOP DRAWINGS 09/10/20
A217 FOURTH FLOOR PARTIAL PLAN - S 01/22/21 A811 FIRESTOPPING DETAILS 01/22/21 M3.0A 1ST FLOOR PLAN HVAC - NORTH 12/18/19 E4.2B POWER - SECOND FLOOR 09/10/20 QF-8.9 HOOD SHOP DRAWINGS 09/10/20
A218 FIFTH FLOOR PARTIAL PLAN - N 01/22/21 A812 FIRESTOPPING DETAILS 01/22/21 M3.0B 1ST FLOOR PLAN HVAC - SOUTH 12/18/19 E4.3A POWER - THIRD FLOOR 09/10/20 QF-8.10 HOOD SHOP DRAWINGS 09/10/20
A219 FIFTH FLOOR PARTIAL PLAN - S 01/22/21 A813 DOOR SCHEDULE 01/22/21 M4.0A 2ND FLOOR PLAN HVAC - NORTH 12/18/19 E4.3B POWER - THIRD FLOOR 09/10/20 QF-8.11 WALK-IN SHOP DRAWINGS 09/10/20
A220 ROOF PARTIAL PLAN - NORTH 01/22/21 A814 DOOR SCHEDULE 01/22/21 M4.0B 2ND FLOOR PLAN HVAC - SOUTH 12/18/19 E4.4A POWER - FOURTH FLOOR 09/10/20
A221 ROOF PARTIAL PLAN - SOUTH 01/22/21 A815 DOOR HARDWARE 01/22/21 M5.0A 3RD FLOOR PLAN HVAC - NORTH 12/18/19 E4.4B POWER - FOURTH FLOOR 09/10/20
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
PLOT DATE
1/22/2021 11:47:22 AM
DATE: 01/22/21
SCALE:
DRAWN: TM
CHCKD: TM
A G001
t: 425-453-0606
www.wattenbarger.com
ABBREVIATIONS SYMBOL LEGEND
& AND DBL DOUBLE HB HOSE BIB PAF POWDER-ACTUATED FASTENER T THERMOSTAT; TREAD
< ANGLE DEPT DEPARTMENT HCW HOLLOW CORE WOOD (DOOR) PART PARTITION TA TOILET ACCESSORIES VIEW REFERENCES
* ASTERISK DET DETAIL HD HOLDDOWN PCF POUNDS PER CUBIC FOOT TB TOWEL BAR
@ AT DF DRINKING FOUNTAIN HDR HEADER PKT POCKET TD TOWEL DISPENSER
C CENTERLINE DIA DIAMETER HDW HARDWARE PLAM PLASTIC LAMINATE TELE TELEPHONE
DIM DIMENSION HM HOLLOW METAL PLAS PLASTER THK THICK
[ CHANNEL DN DOWN HOR HORIZONTAL PLBG PLUMBING T&G TONGUE AND GROOVE DRAWING BLOCK TITLE NEW GRIDLINES BUILDING SECTION CUT
# NUMBER OR POUND DR DOOR HP HIGH POINT POL POLISHED THR THRESHOLD VIEW NUMBER DETAIL NUMBER
d PENNY DS DOWNSPOUT HT HEIGHT PR PAIR TKBD TACKBOARD 1
BELLEVUE, WA 98004
W WIDE FLANGE DWR DRAWER HDWD HARDWOOD PTDR PAPER TOWEL DISPENSER TYP TYPICAL
HWT HOT WATER TANK AND RECEPTOR REFERENCING SHEET NO.
A AIR E EAST PTN PARTITION UH UNIT HEATER
AB ANCHOR BOLT; AIR BARRIER EA EACH ICU INTENSIVE CARE UNIT PLWD PLYWOOD U.N.O. UNLESS NOTED OTHERWISE
AC ACOUSTIC(AL) EL ELEVATION ID INSIDE DIAMETER UR URINAL
A/C AIR CONDITIONING ELEC ELECTRIC(AL) IE INVERT ELEVATION QT QUARRY TILE
ACT ACOUSTICAL CEILING TILE ELEV ELEVATOR IN INCH V VOLT; VINYL WALL SECTION CUT DETAIL CUT ENLARGED DETAIL OR PLAN
AD AREA DRAIN EP ELECTRIC PANELBOARD INSUL INSULAT(ED)(ION) R RISER; RADIUS VAC VACUUM DETAIL NUMBER
DETAIL NUMBER DETAIL NUMBER
ADJ ADJUSTABLE; ADJACENT EQ EQUAL IV INTRAVENOUS RA RETURN AIR VB VAPOR BARRIER SIM
SIM
AFF ABOVE FINISHED FLOOR EQUIP EQUIPMENT RB RESIN BASE VERT VERTICAL 1 1 SIM
ALT ALTERNATE EWC ELECTRICAL WATER HEATER JAN JANITOR RC RESILIENT CHANNEL VG VERTICAL GRAIN 1
A101 A101
ALUM ALUMINUM EXIST EXISTING JTKO JOINT KNOCKOUT REF REFERENCE VCT VINYL COMPOSITION TILE A101 SHEET NO.
SHEET NO. SHEET NO.
AP ACCESS PANEL EXP JT EXPANSION JOINT KPL KICKPLATE REFRG REFRIGERATOR VT VINYL TILE
REGISTERED
STATE OF WASHINGTON
ARCHITECT
ARCH ARCHITECTURAL (ARCHITECT) EXT EXTERIOR REINF REINFORCED
TRAVIS McDANOLD
AUTO AUTOMATIC L LONG; LENGTH REQD REQUIRED W WASTE; WEST; WIDTH; WATER; WATT
FA FIRE ALARM LAB LABORATORY REV REVIS(ED)(ION) W/ WITH
BD BOARD FB FIRE BLANKET; FLUSH BEAM LAM LAMINATE(D) RM ROOM WC WATER CLOSET
BDRM BEDROOM FD FLOOR DRAIN LAV LAVATORY ROS ROUGH OPENING SINK; SOUTH W/D WASHER/DRYER STACKED UNIT EXTERIOR ELEVATIONS INTERIOR ELEVATIONS
BLDG BUILDING FDN FOUNDATION LF LINEAL FOOT WD WOOD DETAIL NUMBER 2
BLKG BLOCKING FE FIRE EXTINGUISHER; LP LOW POINT SAM SELF-ADHERING MEMBRANE WDRB WARDROBE 1 DETAIL
10635
BM BEAM; BENCHMARK FINISHED END LT LIGHT SC SOLID CORE WDO WINDOW NUMBER
BOT BOTTOM FEC FIRE EXTINGUISHER CABINET LUM LUMINOUS SCHD SCHEDULE WG WIREGLASS A101 2 3 A101 1
BSMT BASEMENT FF FINISH FLOOR SD SOAP DISPENSER WH WATER HEATER SHEET NO.
BTWN BETWEEN FFHB FROST-FREE HOSE BIB MAX MAXIMUM SF SQUARE FOOT WIN WINDOW SHEET NO.
FHC FIRE HOSE CABINET MBR MASTER BEDROOM SG SAFETY GLAZING W/O WITHOUT 4
CAB CABINET FIN FINISH(ED) MC MEDICINE CABINET SGD SLIDING GLASS DOOR WR WATER RESISTANT Revision Schedule
CB CATCH BASIN FLR FLOOR(ING); FLUORESCENT MECH MECHANICAL SH SHELF; SHELV(ES)(ING) WRB WEATHER RESISTIVE BARRIER
CCU CORONARY CARE UNIT FOC FACE OF CONCRETE MET METAL SHT SHEET WSCT WAINSCOT # DESCRIPTION DATE
CEM CEMENT FOF FACE OF FINISH MEZZ MEZZANINE SHTG SHEATHING WT WEIGHT
CFCI CONTRACTOR FURNISHED, FOS FACE OF STUD MFR MANUFACTURER SHWR SHOWER WWF WELDED WIRE FABRIC
CONTRACTOR INSTALLED FR FIREPLACE MH MANHOLE SIM SIMILAR
CFOI CONTRACTOR FURNISHED, FT FOOT OR FEET MIN MINIMUM SND SANITARY NAPKIN DISPENSER YD YARD OBJECT REFERENCES
OWNER INSTALLED FTGG FOOTING GAS MISC MISCELLANEOUS SNR SANITARY NAPKIN RECEPTOR
CHBD CHALKBOARD MO MASONRY OPENING SOG SLAB ON GRADE
CJT CONTROL JOINT GA GAGE; GAUGE MTD MOUNTED SSK SERVICE SINK
CLG CEILING GALV GALVANIZED MTL MATERIAL; METAL SST STAINLESS STEEL
PROPERTY CORNER, PLAN KEYNOTE
CLO CLOSET GB GRAB BAR S&G SOAP DISH AND GRAB BAR Room name ROOM NAME & REFERENCES
CLR CLEAR GD GARBAGE DISPOSAL N NITROGEN; NORTH S&P SHELF AND POLE BUILDING LEVEL OR 101 ROOM NUMBER KEYNOTE LEGEND
CMU CONCRETE MASONRY UNIT GI GALVANIZED IRON NO NITROUS OXIDE SPEC SPECIFICATIONS SPOT ELEVATION
CO CLEANOUT GL GLASS; GLAZING NIC NOT IN CONTRACT STC SOUND TRANSMISSION COEFFICIENT
COL COLUMN GLU- GLUE-LAMINATED (TIMBER) NO NUMBER STD STANDARD
GENERAL NOTES
COMP COMPOSITION, COMPACT LAM NOM NOMINAL STL STEEL FIRE-RATED DOOR NUMBER A WINDOW TYPE
CONC CONCRETE GR GRADE NRC NOISE REDUCTION COEFFICIENT STOR STORAGE W00 REFERENCES REFERENCES
CONT CONTINUOUS; CONTINUE GWB GYPSUM WALLBOARD NTS NOT TO SCALE ST&V STAIN AND VARNISH
ASSEMBLY TYPE 101
REFERENCES DOOR SCHEDULE WINDOW
CONTR CONTRACTOR GYP GYPSUM SQ SQUARE ASSEMBLIES SCHEDULE SCHEDULE
CORR CORRIDOR; CORRUGATED OC ON CENTER SW SWITCH
CPT CARPET OD OUTSIDE DIAMETER SV SHEET VINYL
CSK COUNTERSINK(SUNK) OFCI OWNER FURNISHED,
CSS CENTRA-STERILE SUPPLY CONTRACTOR INSTALLED 1 DRAWING REVISION
CT CERAMIC TILE OFOI OWNER FURNISHED, REFERENCES
OWNER INSTALLED REVISION SCHEDULE
OPG OPENING
OZ OUNCE
CENTER
THE SPIRIT AS WELL AS THE LETTER IN WHICH THEY WERE WRITTEN. PROVIDED AS IF DRAWN IN FULL. EARTH, BACKFILL
B. ALL WORK OF THE CONTRACTOR SHALL CONFORM TO THE APPLICABLE BUILDING U. WHENEVER THE WORD "CONTRACTOR" IS USED IN PLANS AND SPECIFICATIONS, IT SHALL
CODES, AND COMPLY WITH ALL GOVERNING LAWS, CODES, ORDINANCES, RULES ALSO MEAN ANY SUBCONTRACTOR, SUB-SUBCONTRACTOR, OR SUPPLIER ENGAGED BY
AND REGULATIONS OF CITY, COUNTY, STATE, AND FEDERAL JURISDICTIONS. THE CONTRACTOR FOR CERTAIN PORTION OF WORK. CONCRETE, CEMENTITUOUS UNDERLAYMENT
C. ALL WORK SHALL BE CONFINED TO PROPERTY OWNED BY THE PERMITTEE OR V. BUILDING TO BE TOTALLY PROTECTED BY AUTOMATIC FIRE SPRINKLER SYSTEM PER
BY THE PARTY CONTRACTING WORK FROM THE PERMITTEE. APPLICABLE NFPA STANDARD 13 AND ALL OTHER APPLICABLE STATE AND LOCAL
SAND, GYPSUM WALLBOARD
CODES.
D. THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR
PROCEDURES, AND SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION W. THE FIRE ALARM SYSTEM SHALL AUTOMATICALLY TRANSMIT ALARMS TO AN APPROVED
WITH THE WORK WILL BE THE RESPONSIBILITY OF THE CONTRACTOR UNLESS CENTRAL ALARM STATION. SUBMIT PLANS, CALCS, ETC. TO THE AUTHORITY HAVING BRICK COMMON/FACE, ADHERED
OTHERWISE SPECIFIED. JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. MANUFACTURED STONE VENEER
E. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT X. PROVIDE SOLID BACKING FOR ALL ATTACHED HARDWARE RODS, HANDRAILS AND GRAB
DOCUMENTS AND SHALL AT ONCE REPORT TO THE ARCHITECT AND THE BARS. CONCRETE MASONRY UNITS
CONSTRUCTION MANAGER ANY ERROR, INCONSISTENCY, OR OMISSION THAT
MAY BE DISCOVERED. Y. PENETRATIONS OF FIRE-RESISTIVE WALLS AND PARTITIONS SHALL BE IN ACCORDANCE
WITH IBC SECTION 714. OUTLET BOXES ON OPPOSITE SIDES OF WALLS AND PARTITIONS
F. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF AT LEAST 24 INCHES, UNLESS ALUMINUM
ACCUMULATION OF WASTE MATERIAL OR RUBBISH CAUSED BY THE OTHERWISE NOTED.
CONTRACTOR'S OPERATIONS.
Z. PENETRATIONS OF FIRE-RESISTIVE CEILINGS (BY ELECTRICAL DEVICES) SHALL BE IN STEEL
G. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL CAREFULLY ACCORDANCE WITH IBC SECTION 714.4.
EXAMINE THE SITE OF THE CONTEMPLATED WORK, AND VERIFY EXISTING AS BUILT
CONDITIONS WHETHER OR NOT NOTED ON THE DRAWINGS. AA. ALL SIGNAGE ADDRESSING ACCESSIBILITY SHALL BE IN ACCORDANCE WITH IBC
SECTION 1111. PLYWOOD
H. CLEAR THE CONTRACT WORK AREA ONLY. PROTECT EXISTING STRUCTURES,
UTILITIES, TREES AND/OR NATURAL GROWTH WHICH ARE REQUIRED TO REMAIN. BB. TESTING OF EMERGENCY LIGHTING IS REQUIRED. CONTRACTOR TO CALL FOR
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
M. DO NOT SCALE DRAWINGS. FF. PROVIDE FIREBLOCKING AND DRAFTSTOPPING PER IBC SECTION 718.
PLOT DATE
RIGID INSULATION
N. VERIFY ALL ROUGH-IN DIMENSIONS (HORIZONTAL AND VERTICAL) FOR ALL GG. ALL APPLIANCES AND LIGHTING FIXTURES ARE TO BE ENERGY STAR RATED 1/22/2021 11:47:24 AM
EQUIPMENT PROVIDED IN THE CONTRACT DOCUMENTS. VERIFY WITH THE WHERE READILY AVAILABLE.
OWNER'S REPRESENTATIVE THE SIZE, SHAPE AND UTILITY REQUIREMENTS OF
EQUIPMENT PROVIDED BY OTHERS. HH. ALL WALLS THAT REQUIRE TO HAVE PROTECTED OPENINGS OR PENETRATIONS BATT INSULATION DATE: 01/22/21
NEEDS TO BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN THE
SCALE: As indicated
O. PROVIDE FURRING AS REQUIRED TO CONCEAL MECHANICAL AND CONCEALED SPACE. PER IBC 703.4
ELECTRICAL WORK IN ALL FINISHED AREAS. DRAWN: TM
FIBER CEMENT CLADDING
P. ALL DOORS LOCATED ADJACENT TO A PERPENDICULAR PARTITION AND NOT CHCKD: TM
LOCATED BY DIMENSION ON PLANS, INTERIOR ELEVATIONS, OR DETAILS SHALL
BE 4" FROM FACE OF STUD TO EDGE OF DOOR OPENINGS. BLDG. SHEET NO.:
BELLEVUE, WA 98004
• FURNITURE SHALL BEAR THE LABEL OF AN APPROVED AGENCY
CONFIRMING COMPLIANCE SECTION 420.6
MATTRESSES: Single-or multiple-station smoke
FIRE ALARM SYSTEMS AND SMOKE ALARMS:
• SHALL RESIST IGNITION BY CIGARETTES AND HAVE A CHAR LENGTH alarms shall be provided per
LESS THAN 2.0" AS DETERMINED BY TESTS CONDUCTED IN Required for I-1 Cond 2 occupancy. 907.2.11.
ACCORDANCE WITH DOC 16 CFR PART 1632
• MATTRESSES SHALL BEAR THE LABEL OF AN APPROVED AGENCY SECTION 427
CONFIRMING COMPLIANCE
Per scoping in 427.1, electric vehicle (EV) charging infrastructure requirements not
applicable to I-1 condition 2 facilities. At Owner's discretion, EV infrastructure may be
FIRE SAFETY provided to meet market demand.
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
SITE STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION OR DEMOLITION
OPERATIONS, NCLUDING THOSE IN UNDERGROUND LOCATIONS, SHALL
COMPLY WITH NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, SECTION 503-504
ALTERATION, AND DEMOLITION OPERATIONS, PER 2006 NFPA 1.
BUILDING HEIGHT AND NUMBER OF STORIES: Table 504.4 - BUILDING 'A'
10635
FIRE DEPARTMENT CONNECTIONS
FIRE DEPARTMENT HOSE CONNECTIONS SHALL BE LOCATED WITHIN 20 CONSTRUCTION TYPE: I-A, SPRINKLERED
FEET OF A FIRE APPARATUS ACCESS ROAD, NOT LESS THAN 18 INCHES AND Basic Height (Feet) Allowed: Unlimited FEET
NOT MORE THAN 4 FEET ABOVE GRADE, OR AS APPROVED BY THE AHJ. Assembly (A-3): Revision Schedule
APPROPRIATE IDENTIFICATION SIGNS SHALL BE PROVIDED AS REQUIRED BY Basic Height (Stories) Allowed: Unlimited STORIES (3 Stories Proposed)
THE AHJ. SECTION 13.2.2.2 AND 13.3.1.2.1 OF NFPA 1 2006, AS AMENDED. Assembly (A-2): # DESCRIPTION DATE
BUILDING CODE
• 2015 INTERNATIONAL BUILDING CODE (IBC) WITH STATE AMENDMENTS – CHAPTER 51-50
STRENGTH SURVEY. CONSTRUCTION TYPE: V-A, SPRINKLERED
WAC, AND LOCAL AMENDMENTS PER PCC 17C.20. • A FINAL TEST WHEN THE SHEET ROCK, CEILINGS AND ALL SHEET Basic Height (Feet) Allowed A,B,S: 70 FEET
PARCEL TAX ID NUMBER:
ANALYSIS
METAL DUCTWORK IS COMPLETE. Basic Height (Feet) Allowed I-1, Condition #2: 70 FEET*
7575000031 • 2015 INTERNATIONAL MECHANICAL CODE (IMC) AND AMENDMENTS – CHAPTER 51-52 WAC & PCC 17C.40.
IF THE BUILDING FAILS TO COMPLY, INSTALLATION OF A DAS SYSTEM WILL BE * Per Washington State amendments to the IBC section 510.2 - #6, The maximum building height in feet
LEGAL DESCRIPTION • 2015 UNIFORM PLUMBING CODE (UPC) AND AMENDMENTS – CHAPTERS 51-56, 51-57 WAC & PCC 17C.50. REQUIRED. shall not exceed the limits set forth in Section 504.3 for the building having the smaller allowable height
Section 21 Township 21 Range 03 Quarter 21 SHERWOOD PARK L 1 & 2 B 1 & N 30 FT & as measured from grade plane. Group I-1 Condition 2 licensed care facilities shall be permitted to use
E 10 FT OF L 1, ALL L 2, 3, 4, 5 & 6 B 2 TOG/W WLY 20 FT OF EAST SIDE DR • 2015 INTERNATIONAL FIRE CODE (IFC) AND AMENDMENTS – CHAPTER 51-54 WAC & PCC 17C.60. the values for maximum height in feet for Group R-2 occupancies.
WAC 50-51-0308
ABUTTING PER VACATION 7-16-34 & TOG/W VAC ALLEY ABUTTING PER VAC DATED ASSISTED LIVING FACILITIES AS LICENSED BY WASHINGTON STATE UNDER CHAPTER 388-78A
• 2015 WASHINGTON STATE ENERGY CODE (WSEC) -CHAPTERS 51-11C AND 51-11R WAC & PCC 17C.70 Assembly (A-2):
3-21-51 LESS ADD R/W PER ETN 620221 DESC AS EXC WLY POR OF BLK 1 COM AT WAC SHALL BE CLASSIFIED AS GROUP I-1, CONDITION 2 OCCUPANCY. (EFFECTIVE 7/1/16) Basic Height (Stories) Allowed: 3 STORIES (3 Stories Proposed)
SW COR OF L 6 TH S 89 DEG 19 MIN 30 SEC E ALG S LI SD LOT A DIST OF 21 FT TO • 2015 INTERNATIONAL INTERNATIONAL SWIMMING POOL AND SPA CODE – PCC 17C.75 Assembly (A-3):
TRUE POB OF SD LI TH N 36 DEG 07 MIN 03 SEC E 80.97 FT TO W MARGIN OF EAST Basic Height (Stories) Allowed: 3 STORIES (3 Stories Proposed)
SIDE DR & TERMINUS OF SD LI TOG/W FOLL DESC PROP THAT POR OF S 1/2 OF • 2015 INTERNATIONAL FUEL GAS CODE (IFGC) AND AMENDMENTS – CHAPTER 51-52 WAC 2015 INTERNATIONAL BUILDING CODE (IBC) Business (B):
SW OF SE OF SW 16-21-03E LY W OF W LI OF EAST SIDE DR EXC N 180.03 FT OF E Basic Height (Stories) Allowed: 4 STORIES (3 Stories Proposed)
242.72 THEREOF SUBJ TO EASE ADMIN COMBO OF 001-0, 002-2, 003-0 & 004-0 & • 2015 NATIONAL FUEL GAS CODE (NFPA 54) – CHAPTER 51-52 WAC COMPLIANCE ANALYSIS Institutional (I-1 Cond 2):
03-21-16-3-177 FOR TAX PURPOSES ONLY SEG Z-0729 SG RJ Basic Height (Stories) Allowed: 3 STORIES (3 Stories Proposed)
• 2014 LIQUEFIED PETROLEUM GAS CODE (NFPA 58) – CHAPTER 51-52 WAC Storage (S-1):
SECTION 303 - 312
Basic Height (Stories) Allowed: 4 STORIES (3 Stories Proposed)
AREA OF PROPOSED DEVELOPMENT: • 2017 NATIONAL ELECTRIC CODE (NFPA 70) AND AMENDMENTS - CHAPTER 296-46B WAC OCCUPANCY CLASSIFICATIONS:
CENTER
• ICC/ANSI A117.1 - 2009
OCCUPANCY CLASSIFICATIONS A-2, A-3, B, I-1 COND. 2, S-1, S-2
• 2010 AMERICANS WITH DISABILITIES ACT
A
SECTION 406.4
• PIERCE COUNTY CODE Clear height (required) 7'-0"minimum 109.5' 105.0'
TYPE OF CONSTRUCTION SUMMARY Clear height (provided) 7'-0"
Clear height at accessible van route: 8'-2" minimum
TYPE I-A (BASEMENT, FIRST FLOOR, SECOND FLOOR) UNIT SUMMARY Clear height at loading (provided)
Vehicle barriers:
14'-0"
2'-9" minimum at >1'-0" grade differential
TYPE V-A (THIRD, FOURTH, FIFTH FLOORS)
68' - 0"
NFPA TYPE 13 SPRINKLERS THROUGHOUT
F
PIERCE CO. DWELLING UNITS
FULL KITCHEN SECTION 406.6 - Enclosed parking garages
(DWELLING
BUILDING GROSS AREA UNIT TYPE NAME
UNIT
COUNT
ACCESSIBILITY
TYPE UNIT)
DWELLING
UNIT COUNT Ventilation: Mechanical ventilation shall be provided 106'
118.0'
- 0"
158' - 1 1/2"
(shaft located at south end)
AL-1 BEDROOM UNIT B1 20 ANSI TYPE 'B' Yes 20
LEVEL NAME AREA 120.75'
107' - 0"
AL-1 BEDROOM UNIT B1b 2 ANSI TYPE 'B' Yes 2 Automatic sprinkler system: NFPA 13 sprinklers provided throughout
B
0"
SECTION 420.2
90' - 1 1/2"
AL-1 BEDROOM UNIT B4 2 ACCESSIBLE No 0
19,794 SF
119
120' - 0"
118' - 0"
12 0' -
' - 0"
110
' - 0"
AL-1 BEDROOM UNIT B5 2 ACCESSIBLE Yes 2
0"
SEPARATION WALLS: 1 HR-FIRE PARTITION
D
AL-1 BEDROOM UNIT B6 3 ANSI TYPE 'B' Yes 3
"
'- 0
111
BLDG A - 1ST FLOOR COMMON SPACE 9,071 SF Required for I-1 occupancy.
AL-1 BEDROOM UNIT B7 3 ANSI TYPE 'B' Yes 3
BLDG A - 1ST FLOOR MEMORY CARE 3,208 SF 2' -
0"
11
AL-1 BEDROOM UNIT B10 1 ANSI TYPE 'B' Yes 1 HORIZONTAL SEPARATION: 1 HR PER IBC 711 0"
BLDG A - 1ST FLOOR MEMORY CARE 2,484 SF
-
4'
11
AL-1 BEDROOM UNIT B11 1 ANSI TYPE 'B' No 0 Required for I-1 Cond 2 occupancy.
BLDG A - 1ST FLOOR MEMORY CARE 899 SF
0"
BLDG A - 1ST FLOOR BACK OF HOUSE 2,184 SF
-
5'
11
AL-2 BEDROOM UNIT C1 6 ANSI TYPE 'B' Yes 6 119.5' 116.0'
20,653 SF
AL-2 BEDROOM UNIT C2 2 ANSI TYPE 'B' Yes 2 SECTION 420.4 11
6' -
0"
A G003
MC-STUDIO UNIT MC6 1 ANSI TYPE 'B' No 0
BLDG A - 5TH FLOOR AL UNITS 10,501 SF
MC-STUDIO UNIT MC7 1 ANSI TYPE 'B' No 0
21,874 SF SEE SHEETS G010, G012, G014, G016, & G018 FOR SMOKE COMPARTMENT DIAGRAMS,
108 79
Grand total 134,204 SF CALCULATIONS AND REFUGE AREAS
t: 425-453-0606
www.wattenbarger.com
SECTION 506 SECTION 705 SECTION 907
MIXED OCCUPANCY, MULTISTORY BUILDINGS: SECTION 1014 - 1015
The total building area shall be such that the aggregate sum of the ratios of the actual Per 705.8.1: The maximum area of protected and unprotected openings permitted in an exterior 907.5.2.2 Emergency voice/alarm communication systems
BUILDING AREA: wall in any story of a building shall not exceed the percentages specified in table 705.8. REQUIRED HANDRAIL HEIGHT: 34" - 38" above nosing
area of each story divided by the allowable area of such stories, determined in Emergency voice/alarm communication systems shall be designed and installed in
Table 506.2 accordance with NFPA 72. The operation of any automatic fire detector, sprinkler waterflow
accordance with equation: A(a) = [A(t) + NS x I(f))], shall not exceed three. MAXIMUM AREA OF EXTERIOR WALL OPENINGS: GUARD HEIGHT: 42"
CONSTRUCTION TYPE: I-A V-A device or manual fire alarm box shall automatically sound an alert tone followed by voice
Assembly (A-2): GUARDRAIL OPENINGS ALLOWED: <4" sphere up to 42"
BUILDING A: FLOORS 2-5 FIRE SEP. DIST. DEGREE OF PROTECTION ALLOWABLE AREA instructions giving approved information and directions for a general or stage evacuation in
Basic Area per Floor Allowed: Unlimited 34,500 SF <6" sphere in triangle between
A-2 OCC 0' ≤ x ≤ 3' to P.L Unprotected, Sprinklered NP (N/A) accordance with the building’s fire safety and evacuation plans required by Section 404 of
Assembly (A-3): riser and tread
A(a) = [A(t) + NS x I(f))] 3' ≤ x ≤ 5' to P.L Unprotected, Sprinklered 15% (N/A) the International Fire Code. In high rise buildings, the system shall operate on at least the
Basic Area per Floor Allowed: Unlimited 34,500 SF GUARD LOCATIONS: Where vertical separation >30"
A(a) = [34,500 + (11,500 x 0.36)] 5' ≤ x ≤ 10' to P.L Unprotected, Sprinklered 25% (N/A) alarming floor, the floor above and the floor below. Speakers shall be provide throughout
Business (B): Where roof equip. is <10' to roof edge
A(a) = 38,640 SF ALLOWED 10' ≤ x < 15' to P.L Unprotected, Sprinklered 45% (N/A) the building by paging zones. At a minimum, paging zones shall be provided as follows:
Basic Area per Floor Allowed: Unlimited 54,000 SF Where roof hatch is <10' to roof edge
A-3 OCC 15' ≤ x < 20' to P.L Unprotected, Sprinklered 75% (N/A) 1. Elevator groups
BELLEVUE, WA 98004
Basic Area per Floor Allowed: Unlimited 42,000 SF B = 300' (sprinklered)
B OCC Fire Separation Distance is measured from the building face to the following:
Storage (S-2) Exception: In Group I-1 and I-2 occupancies, the alarm shall sound in a constantly attended S-2 = 400' (sprinklered)
A(a) = [A(t) + NS x I(f))] 1. closest interior lot line
Basic Area per Floor Allowed: Unlimited 63,000 SF A(a) = [54,000 + (18,000 x 0.36)] area and a general occupant notification shall be broadcast over the overhead page.
MOST RESTRICTIVE BUILDING AREA = I-1 = 31,500 SF PER FLOOR 2. centerline of street, alley, or public way
A(a) = 60,480 SF ALLOWED
(SEE ALSO CALCULATIONS IN 506.2.4) S1 OCC
3. Imaginary line between two buildings on the property 907.5.2.2.1 Manual Override SECTION 1020
A(a) = [A(t) + NS x I(f))] A manual override for emergency voice communication shall be provided on a selective MINIMUM CORRIDOR WIDTH: 44" or 36" when occ. load <50
E Elevation - Center line between Retail Bldg (34'-9" actual): > 30' No Limit and all-call basis for all paging zones MAXIMUM DEAD END: 50' max. for B, S-1, S-2 occ.
A(a) = [42,000 + (14,000 x 0.36)] S Elevation - Interior property line (15' actual): ≤ 15' 75%
A(a) = 47,040 SF ALLOWED *20' max. for A-2, A-3, I-1 occ.
W Elevation - Interior property line (15' actual): ≤ 15' 75% 907.5.2.2.2 Live Voice Messages
BUILDING 'B' I-1 CONDITION #2 OCC N Elevation - Interior property line (28'-11" actual): > 25' No Limit
A(a) = [A(t) + NS x I(f))] The emergency voice/alarm communication system shall have the capability to broadcast * PER EXCEPTION #2 IN BUILDINGS EQUIPPED THROUGHOUT WITH AN
A(a) = [31,500 + ( 10,500 x 0.36)] live voice messages by paging zones on a selective and all-call basis. AUTOMATIC FIRE SPRINKLER SYSTEM THE LENGTH OF DEAD-END
EXTERIOR WALL FIRE RESISTANCE RATINGS:
REGISTERED
STATE OF WASHINGTON
ARCHITECT
A(a) = 35,280 SF Fire separation distance of >10 feet: rated for exposure to fire from the inside. CORRIDORS SHALL NOT EXCEED 50' FOR THE FOLLOWING
TRAVIS McDANOLD
907.5.2.2.3 Alternate uses OCCUPANCIES: B, E, F, I-1, M, R-1, R-2, R-4, S, U.
Fire separation distance of ≤ 10 feet: rated for exposure to fire from both sides.
BUILDING 'A' The emergency voice/alarm communication system shall be allowed to be used for other
SECTION 706 - 712 announcements, provided the manual fire alarm use takes precedence over any other use CORRIDOR CONTINUITY: Corridor shall be continuous to an exit
TOTAL ALLOWABLE AREA CALCULATION
STORY I-1* FIRE RESISTANCE REQUIREMENTS: 907.5.2.2.5 Emergency power Foyers, lobbies or reception rooms
ALLOWABLE AREA 35,280 (MAX. ACTUAL = 24,542 SF) FIRE WALLS: (N/A) Emergency voice/alarm communications systems shall be provide with emergency power in
10635
constructed as required for corridors
PER FLOOR FIRE BARRIERS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS accordance with Section 2702. The system shall be capable of powering the required load hall not be construed as intervening
GROSS BUILDING AREAS - BLDG 'A' FIRE DOOR & SHUTTER 3-HR* (180 MIN) for a duration of not less than 24 hours, as required in NFPA 72 rooms.
*Per 508.3.1 For non-separated ASSEMBLY RATING: 3-HR*
occupancies, the allowable
OCCUPANCY 2ND FLOOR 24,542 SF
building area and height shall be
FIRE BARRIERS
SECTION 912 SECTION 1023
Level CLASS. AREA 0.696 FIRE DOOR & SHUTTER 1 1/2-HR (90 MIN)
based on the most restrictive MINIMUM EXIT PASSAGEWAY WIDTH: 44" or 36" when occ. load <50 Revision Schedule
ASSEMBLY RATING: 2-HR FIRE DEPARTMENT CONNECTION:
allowances for the occupancy SHAFTS (4 or more stories) Provide in accordance with requirements of section 912 & Fire Marshal's Office
3RD FLOOR 24,073 SF # DESCRIPTION DATE
BLDG A - BASEMENT S-2 17,939 SF groups under consideration for the
BLDG A - BASEMENT B 2,727 SF
0.696
type of construction in accordance
ASSEMBLY RATING 2-HR SECTION 1029
FIRE PARTITIONS*:
20,666 SF
4TH FLOOR 22,002 SF
with section 503.1. FIRE DOOR & SHUTTER 3/4-HR (45 MIN) SECTION 1004 COMMON PATH OF EGRESS 30' or 75' when occ. load < 50
BLDG A - 1ST FLOOR S-2 801 SF ASSEMBLY RATING: 1-HR
0.624 SEE LIFE SAFETY PLANS FOR OCCUPANT LOAD TABULATIONS
BLDG A - 1ST FLOOR I-1 12,180 SF
BLDG A - 1ST FLOOR B 4,002 SF MAX RATIO (for building)
SMOKE BARRIERS: Occupant load signage shall be posted as indicated on LIFE SAFETY PLANS sheets SECTION 1030
SUM OF RATIOS 2.034 FIRE DOOR & SHUTTER 1/3-HR (20 MIN) G010 - G015
BLDG A - 1ST FLOOR A-3 2,465 SF 2.034 < 3.000, THEREFORE OK EMERGENCY ESCAPE & RESCUE AT WINDOWS:
ASSEMBLY RATING: 1-HR
BLDG A - 1ST FLOOR A-2 986 SF Not required - means of egress in accordance with table 1006.2.1 provided.
SMOKE PARTITIONS:
20,433 SF ASSEMBLY RATING 0-HR
BLDG A - 2ND FLOOR I-1 14,824 SF ** HORIZONTAL ASSEMBLY BETWEEN BLDG 'A' & 'B' SECTION 1101
BLDG A - 2ND FLOOR B 1,070 SF SECTION 508 ** CORRIDORS PER 1020. SECTION 1005 This project has been designed in accordance with 2010 ADA guidelines,
BLDG A - 2ND FLOOR A-3 6,062 SF FIRE DOORS & SHUTTER 1/3-HR the 1988 Fair Housing Act and ANSI A117.1 - 2009.
BUILDING CODE
BLDG A - 2ND FLOOR A-2 907 SF MIXED USE AND OCCUPANCY: ASSEMBLY RATING 1-HR MIN. EGRESS WIDTH PER OCCUPANT: (see also section 1008)
508.2: ACCESSORY OCCUPANCIES - NOT USED STAIRS: .3 in. / Occupant (sprinklered)
22,863 SF
SECTION 1106
ANALYSIS
SECTION 720.2 & 720.3 OTHER EGRESS COMPONENTS. .2 in. / Occupant (sprinkled)
Total Building Area 63,962 SF
508.2.2: ALLOWABLE BUILDING HEIGHT PARKING PER IBC 1106.1 & 1106.2
The allowable height and number of stories of the building containing Concealed and Exposed insulation shall have a flame spread index of not more than 25 and a
smoke-developed index of not more than 450. SECTION 1006 TOTAL STALLS PROVIDED = 80
accessory occupancies shall be in accordance with Section 504 for the REQUIRED ACCESSIBLE SPACES = 4
main occupancy of the building. NUMBER OF EXITS AND EXIT ACCESS DOORWAYS:
508.2.3: ALLOWABLE BUILDING AREA
SECTION 803 See summary on the LIFE SAFETY PLANS.
PROVIDED ACCESSIBLE SPACES = 4
REQUIRED ACCESSIBLE VAN STALLS = 1
The allowable area of the building shall be based on the applicable INTERIOR FINISH CLASSIFICATIONS BY OCCUPANCY TYPE: (sprinklered)
PROVIDED ACCESSIBLE VAN STALLS = 1
GROSS BUILDING AREAS - BLDG 'B' provisions of Section 506 for the main occupancy of the building. NUMBER OF EXITS:
Aggregate accessory occupancies shall not occupy more that 10 percent OCC. GROUP LOCATION FINISH CLAS.
OCCUPANCY of the floor area of the story in which they are located and shall not exceed A-2, A-3 Exit Enclosures & Corridors class B FIRST STORY ABOVE OR BELOW GRADE PLANE: SECTION 1107
the tabular values for nonsprinklered buildings in Table 506.2 for each A-2, A-3 Enclosed Rooms & Spaces class C Occupant load A,B = 49 1 Exit required
Level CLASS. AREA B, I-1 Exit Enclosures class B
All Dwelling Units & Sleeping Rooms to meet Federal Fair Housing Accessibility
such accessory occupancy. Occupant load S = 29 1 Exit required guidelines (2009 ANSI 117.1) for type 'B' units unless otherwise noted.
508.3: NON SEPARATED OCCUPANCIES B, I-1 Corridors class C Occupant load I-1 = 10 1 Exit required
BLDG A - 3RD FLOOR I-1 22,470 SF B, I-1 Enclosed Rooms & Spaces class C
The allowable area and height of the building is determined by the Min. 10% Accessible Units for I-1 Condition #2, per 1107.5.1.1
BLDG A - 3RD FLOOR A-3 2,072 SF S-1,S-2 Exit Enclosures, Corridors & Rooms class C SECOND STORY ABOVE OR BELOW GRADE PLANE:
requirements of the most restrictive occupancy. See section 506. Remaining (90%) Type B units for I-1 Condition #2, per 1107.5.1.2
24,542 SF Occupant load B,S = 29 Exit required
BLDG A - 4TH FLOOR I-1 23,585 SF
BLDG A - 4TH FLOOR B 488 SF SECTION 903 108 UNITS x .10 = 10.8 OR 11 UNITS REQUIRED.
THIRD STORY ABOVE OR BELOW GRADE PLANE:
24,073 SF SECTION 509 Occupant load NOT PERMITTED
11 UNITS PROVIDED. SEE UNIT SUMMARY ON G003 FOR LIST OF UNITS.
CENTER
REQUIRED LOCATIONS: SECTION 1007 Min. 2% of dwelling units & sleeping rooms shall provide communications features
SECTION 510 -In every required interior exit stairway, at each floor level above or below grade, required by the Americans with Disabilities Act (2010 ADAAG)
connections shall be located at an intermediate floor level landing between floors. EXIT ACCESS SEPARATION: At least 1/3 The maximum diagonal measurement of
the building or space for sprinklered buildings
SECTION 506.2.4 WE ARE APPLYING SECTION 510.2 FOR HORIZONTAL BUILDING SEPARATION -On each side of the wall adjacent to the exit opening of a horizontal exit. 108 UNITS x .02 = 2.16 OR 3 UNITS REQUIRED.
1. Building separated with a 3-hr rated horizontal assembly. -At every exit passageway at the entrance from the exit passageway to other areas 3 UNITS PROVIDED. SEE ELECTRICAL UNIT PLANS
2. Building below is of type I-A construction. of the building.
BUILDING 'A' - ALLOWABLE AREA
3. All shafts, stairways, through the assembly are 2-hr with protected openings. -Where the roof has a slope less than 4/12 each standpipe shall be SECTION 1008
ROLL IN SHOWERS REQUIRED PER IBC 1106.1.1
MAX. ALLOWABLE = UNLIMITED 4. Building above does not contain any A, B, M, R, I, S occupancies with an individual provided with a hose connection located either on the roof or at the highest EGRESS ILLUMINATION: 108 UNITS = 2 UNITS REQUIRED.
ACTUAL AREA = 63,962 SF occupant load over 300.* landing of a stairway with stair access to the roof. An additional hose connection Provide not less than 1 footcandle at walking surface in all A & I-1 occupancies. 30 UNITS PROVIDED.
5. Building below the assembly has a sprinkler system in per 903.3.1.1 and is not shall be provided at the top of the most hydraulically remote standpipe for testing
group H occupancy. purposes. Not required in sleeping units at I-1 occupancies.
BUILDING 'B' - ALLOWABLE AREA
6. Maximum bldg. height for most restrictive occupancy (A-3 & I-1 Condition #2 does not -Any other locations as required by the fire marshal.
SECTION 1203.5
exceed that allowed when taken from the grade plan. Provide with emergency power for illumination, not less than 90 min. (battery backup Every occupied space shall be naturally or mechanically ventilated.
274' - 1" SECTION 906 or emergency generator) at initial not less than an average of 1 footcandle. Natural ventilation of an occupied space: 4% of floor area min.
@ 14'-10" * I-1 Condition #2 occupancy included per Washington State Amendments to IBC 510.2 #4. FIRE EXTINGUISHER TYPE: 2A minimum rating, Typ. (See keynotes on
life safety plans.) In the event of power failure, an emergency electrical system shall automatically illuminate: SECTION 1205
• Interior and exterior exit access stairways and ramps
@ 30'-0" @14'-10"
Class K at Commercial Kitchen Every occupied space shall be provided with natural light.
34' - 2"
@ 30'-0"
note: class K fire extinguishers may Natural light of an occupied space: 8% of floor area min.
not be equipped with extended wand • Vestibules and areas on the level of discharge used for exit discharge Section 1028.1
type discharge devices. • Exterior landings as required per Section 1010.1.6
FIRE RESISTANCE REQUIREMENTS, TYPE I-A CONSTRUCTION: BLDG 'A' - (FLR B,1,2) SECTION 1207
34' - 5"
90' - 0"
@ 30'-0" The installation, maintenance, selection, and distribution of portable fire Floor/Ceilings: STC 50 or NIC 45 & IIC 50 or FIIC 45
FLOOR CONSTRUCTION: 2-HR* 1009.2.1 - ELEVATOR: Standby power shall be provided and the elevator shall be accessed
ROOF CONSTRUCTION: 1 1/2-HR extinguishers shall be in accordance with NFPA 10, Standard for Portable Fire from an area of refuge.*
* 3 HR PER IBC 510.2 WA STATE AMENDMENTS AT PODIUM Extinguishers, and Section 13.6. 2018 NFPA 1. * Per exception #1 not required in buildings equipped with an automatic fire sprinkler system SECTION 1505
per 903.3.1.1, when the floor is provided with a horizontal exit located at or above the level of MINIMUM ROOF COVERING CLASSIFICATION: Type IA & VA: CLASS B, min.
SECTION 907 exit discharge.
907.2.6 Group I-1: A manual fire alarm system that activates the occupant notification SECTION 2406
FIRE RESISTANCE REQUIREMENTS, TYPE V-A CONSTRUCTION: BLDG 'B' (FLR 3,4,5) 1009.3 - MINIMUM STAIRWAY WIDTH: 48"* between handrails and shall either incorporate
system in accordance with Section 907.5 shall be installed in Group I occupancies. An
BELLEVUE, WA 98004
A-2 1 PER 200 FOR THE BACK OF HOUSE 2,484 SF 6,704 SF
B 9,327 SF 87 75 75 REMAINDER 113 UNIT MC2 MC-STUDIO ANSI TYPE 'B' 415 SF 1 No
I-1 88,548 SF 721 114 UNIT MC2-b MC-STUDIO ANSI TYPE 'B' 435 SF 1 No 2,184 SF
1 PER 1 PER EXCEEDING 50. BACK OF HOUSE
S-2 18,740 SF 89 A-3 125 65 1 PER 200 ** 1 PER 40 FOR 131 UNIT MC3 MC-STUDIO ANSI TYPE 'B' 369 SF 1 No
THE FIRST 80 132 UNIT MC3-b MC-STUDIO ANSI TYPE 'B' 340 SF 1 No 4,918 SF
B 1 PER 25 * 1 PER 40 ** AND 1 PER 80 133 UNIT MC3 MC-STUDIO ANSI TYPE 'B' 340 SF 1 No
FOR THE 134 UNIT MC3-b MC-STUDIO ANSI TYPE 'B' 369 SF 1 No
I-1 1 PER 10 1 PER 10 REMAINDER 136 UNIT MC5 MC-STUDIO ANSI TYPE 'B' 430 SF 1 No
EXCEEDING 80. 137 UNIT MC4 MC-STUDIO ACCESSIBLE 386 SF 1 No COMMON SPACE COMMON
S-1, S-2 1 PER 100 1 PER 100 138 UNIT MC4-b MC-STUDIO ACCESSIBLE 389 SF 1 No
139 UNIT MC1 MC-STUDIO ANSI TYPE 'B' 382 SF 1 No 9,071 SF 10,922 SF
140 UNIT MC1-b MC-STUDIO ANSI TYPE 'B' 386 SF 1 No
141 UNIT MC1 MC-STUDIO ANSI TYPE 'B' 376 SF 1 No COVERED FIRE AREA
REGISTERED
STATE OF WASHINGTON
ARCHITECT
OCC. OCC. LOAD WATER CLOSETS LAVATORIES
142 UNIT MC1-b MC-STUDIO ANSI TYPE 'B' 376 SF 1 No
TRAVIS McDANOLD
TYPE TOTAL REQUIRED SUM REQ'D PROVIDED REQUIRED SUM REQ'D PROVIDED 607 SF
143 UNIT MC1 MC-STUDIO ANSI TYPE 'B' 386 SF 1 No
A-2 330 TOTAL REQ'D 144 UNIT MC1-b MC-STUDIO ANSI TYPE 'B' 386 SF 1 No COVERED FIRE AREA
TOTAL TOTAL REQ'D TOTAL 145 UNIT MC1 MC-STUDIO ANSI TYPE 'B' 374 SF 1 No
(M) 165 1 per 75 = 165 / 75 = 2.2 MEN: 1 per 200 = 165 / 200 = 0.83 937 SF
PROVIDED EACH GENDER PROVIDED 146 UNIT MC1-b MC-STUDIO ANSI TYPE 'B' 376 SF 1 No
(W) 165 1 per 75 = 165 / 75 = 2.2 2.2 + 3.2 + 1.37 1 per 200 = 165 / 200 = 0.83
MEN: 73 W.C.'S 0.83 +2.0 + 1.05 MEN: 73 LAV'S 23 8919 SF 23
+ 0.01 + 0.435 +
= 73 + .01 + .435 + = 73
10635
A-3 796 36.05 = 43.27
5 PROVIDED 36.05 = 40.38 5 PROVIDED
(M) 398 1 per 125 = 398 / 125 = 3.2 = 44
AT COMMON
1 per 200 = 393 / 200 = 2.0
= 41 AT COMMON
BLDG A - 2ND FLOOR COVERED FIRE AREA
(W) 398 1 per 65 = 398 / 65 = 6.1 1 per 200 = 393 / 200 = 2.0 214 UNIT C6 AL-2 BEDROOM ACCESSIBLE 1029 SF 2 No
TOTAL REQ'D AREAS AND AREAS AND 68 215 UNIT B4 AL-1 BEDROOM ACCESSIBLE 586 SF 1 No 334 SF
B 87 1 per 25 = 50 / 25 = 2.0 WOMEN: 68 PROVIDED 1 per 40 = 80 / 40 = 2.0 PROVIDED @ 216 UNIT B4 AL-1 BEDROOM ACCESSIBLE 586 SF 1 No
@ UNITS UNITS PARKING
1 per 50 = 37 / 50 = .74 2.2 + 6.1 + 1.37 1 per 80 = 7 / 80 = 0.1 224 UNIT B10 AL-1 BEDROOM ANSI TYPE 'B' 663 SF 1 No
Revision Schedule
(M = 1.37, W = 1.37) + 0.01 + 0.435 + (M = 1.05, W = 1.05) 225 UNIT B11 AL-1 BEDROOM ANSI TYPE 'B' 645 SF 1 No 14,876 SF
36.05 = 46.16 TOTAL TOTAL 226 UNIT A1 AL-STUDIO ANSI TYPE 'B' 407 SF 1 No
PROVIDED PROVIDED MEMORY CARE # DESCRIPTION DATE
S-1 1 1 per 100 = 1 / 100 = 0.01 = 47 1 per 100 = 4 / 100 = 0.01 227 UNIT A1 AL-STUDIO ANSI TYPE 'B' 398 SF 1 No
(M = 0.02, W = 0.02) WOMEN: (M = 0.01, W = 0.01) WOMEN: 74 228 UNIT A1 AL-STUDIO ANSI TYPE 'B' 398 SF 1 No 3,208 SF
76 W.C.'S LAV'S 229 UNIT A1 AL-STUDIO ANSI TYPE 'B' 407 SF 1 No
S-2 89 1 per 100 = 89 / 100 = 0.89 = 76 1 per 100 = 89 / 100 = 0.89 = 74 240 UNIT A1 AL-STUDIO ANSI TYPE 'B' 399 SF 1 No
(M = 0.435, W = 0.435) 7 PROVIDED (M = 0.435, W = 0.435) 5 PROVIDED 241 UNIT A1 AL-STUDIO ANSI TYPE 'B' 399 SF 1 No
AL UNITS AL UNITS
AT COMMON AT COMMON
I-1 721 1 per 10 = 721 / 100 = 72.1 AREAS AND 1 per 10 = 721 / 100 = 72.1 AREAS AND 69
242 UNIT C10 AL-2 BEDROOM ANSI TYPE 'B' 928 SF 2 No MEMORY CARE 3,091 SF 2,451 SF
243 UNIT C9 AL-2 BEDROOM ANSI TYPE 'B' 931 SF 2 No
(M = 36.05, W = 36.05) 69 PROVIDED (M = 36.05, W = 36.05) PROVIDED @ COVERED FIRE AREA
246 UNIT A1 AL-STUDIO ANSI TYPE 'B' 397 SF 1 No 1,540 SF
@ UNITS UNITS
247 UNIT A1 AL-STUDIO ANSI TYPE 'B' 399 SF 1 No
248 UNIT A1 AL-STUDIO ANSI TYPE 'B' 402 SF 1 No
520 SF
249 UNIT A1 AL-STUDIO ANSI TYPE 'B' 405 SF 1 No
250 UNIT A1 AL-STUDIO ANSI TYPE 'B' 401 SF 1 No
SECTION 3005 251 UNIT C8 AL-2 BEDROOM ANSI TYPE 'B' 855 SF 2 No
BUILDING CODE
252 UNIT C7 AL-2 BEDROOM ANSI TYPE 'B' 891 SF 2 No
20 11529 SF 25
MACHINE ROOMS
ANALYSIS
3005.1 Venting. BLDG A - 3RD FLOOR
Elevator machine rooms, shall be provided with a independent ventilation or air-conditioning system to protect against the 303 UNIT B3 AL-1 BEDROOM ANSI TYPE 'B' 625 SF 1 No
over-heating of the electrical equipment. The system shall be capable of maintaining temperatures within the range 304 UNIT B3 AL-1 BEDROOM ANSI TYPE 'B' 625 SF 1 No MEMORY CARE COVERED FIRE AREA
305 UNIT B3 AL-1 BEDROOM ANSI TYPE 'B' 626 SF 1 No 1,268 SF
established for the elevator equipment. 416 SF
306 UNIT C1 AL-2 BEDROOM ANSI TYPE 'B' 929 SF 2 No
3005.4 elevator machine rooms outside but attached to a hoistway that have openings into the hoistway shall be enclosed 307 UNIT C1 AL-2 BEDROOM ANSI TYPE 'B' 929 SF 2 No
with fire barrier constructed in accordance with section 707 -Fire Barriers. 308 UNIT B5 AL-1 BEDROOM ACCESSIBLE 744 SF 1 No
316 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
317 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
SECTION 3006 318 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 618 SF 1 No
319 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 617 SF 1 No
HOISTWAY OPENING PROTECTION 320 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
3006.2 Hoistway opening protection required 321 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
Elevator hoistway door openings shall be protected in accordance with section 3006.3, where an elevator hoistway connects 322
323
UNIT B2
UNIT B6
AL-1 BEDROOM
AL-1 BEDROOM
ANSI TYPE 'B'
ANSI TYPE 'B'
618 SF
616 SF
1
1
No
No
BLDG A - BASEMENT BLDG A - 1ST FLOOR BLDG A - 2ND FLOOR
more than three stories, is required to be enclosed in a shaft enclosure in accordance with Section 712.1.1 when any of the 324 UNIT B7 AL-1 BEDROOM ANSI TYPE 'B' 580 SF 1 No 1/32" = 1'-0" 1/32" = 1'-0" 1/32" = 1'-0"
following conditions apply. 325 UNIT B8 AL-1 BEDROOM ANSI TYPE 'B' 624 SF 1 No
326 UNIT B9 AL-1 BEDROOM ANSI TYPE 'B' 642 SF 1 No
327 UNIT B1b AL-1 BEDROOM ANSI TYPE 'B' 650 SF 1 No
2. The building contains a Group I condition #2. 328 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
CENTER
FLOOR 5 ELEV. - DOORS PER 3006.3 #3** 336 UNIT C3 AL-2 BEDROOM ACCESSIBLE 934 SF 2 No
AL UNITS
337 UNIT C2 AL-2 BEDROOM ANSI TYPE 'B' 877 SF 2 No
28 18785 SF 32 2,525 SF
* Exception #2 Protection of the elevator hoistway door openings is not required at the level(s) of exit discharge, provided the BLDG A - 4TH FLOOR AL UNITS
level(s) of exit discharge is equipped with an automatic fire sprinkler system in accordance with section 903.3.1.1. 403 UNIT B3 AL-1 BEDROOM ANSI TYPE 'B' 625 SF 1 No
19,154 SF
404 UNIT B3 AL-1 BEDROOM ANSI TYPE 'B' 625 SF 1 No
405 UNIT B3 AL-1 BEDROOM ANSI TYPE 'B' 626 SF 1 No COMMON AL UNITS AL UNITS AL UNITS
** 3006.3 #3 406 UNIT C1 AL-2 BEDROOM ANSI TYPE 'B' 929 SF 2 No COMMON
Additional door shall be provided at each elevator hoistway door opening, and such door shall comply with the smoke and 768 SF 763 SF COMMON 612 SF
407 UNIT C1 AL-2 BEDROOM ANSI TYPE 'B' 929 SF 2 No 4,851 SF 4,206 SF
draft control door assembly requirements 408 UNIT B5 AL-1 BEDROOM ACCESSIBLE 744 SF 1 No 8,236 SF
415 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 585 SF 1 No
in Section 716.5.3.1when tested in accordance with UL 1784 without an artificial bottom seal.
416 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
417 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
418 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 617 SF 1 No
419 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 617 SF 1 No
420 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
421 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
422 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 618 SF 1 No AL UNITS
423 UNIT B6 AL-1 BEDROOM ANSI TYPE 'B' 616 SF 1 No 18,973 SF
424 UNIT B7 AL-1 BEDROOM ANSI TYPE 'B' 580 SF 1 No
425 UNIT B8 AL-1 BEDROOM ANSI TYPE 'B' 624 SF 1 No
426 UNIT B9 AL-1 BEDROOM ANSI TYPE 'B' 643 SF 1 No
WASHINGTON STATE ENERGY CODE 427 UNIT B1b AL-1 BEDROOM ANSI TYPE 'B' 649 SF 1 No
428 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
SECTION C301.1 429 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 617 SF 1 No
430 UNIT B2 AL-1 BEDROOM ANSI TYPE 'B' 618 SF 1 No
CLIMATE ZONE: PIERCE: ZONE 4C (MARINE), COMMERCIAL BUILDING 431 UNIT B1 AL-1 BEDROOM ANSI TYPE 'B' 633 SF 1 No
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
P.C.C. 18A.15.020 - RESIDENTIAL DENSITY REQUIRED RECREATIONAL AREAS: 79 DWELLING UNITS x 500 SF/DU = 39,500 SF MINIMUM REQUIRED.
P.C.C. 18J.15.030 - TREE CONSERVATION
BELLEVUE, WA 98004
BASE DENSITY: 16 DWELLING UNITS / ACRE; MAX DENSITY: 25 DWELLING UNITS / ACRE
• SEE LANDSCAPE PLANS, SHEETS L3.0. P.C.C. 18J.15.185 - RESIDENTIAL
PERMITTED RESIDENTIAL DENSITY:
GROSS SITE AREA = 139,614 S.F.; EXISTING PRIVATE ROAD EASEMENT = 3,900 S.F. ASSISTED LIVING FACILITIES IN NON-RESIDENTIAL ZONING CLASSIFICATIONS ARE EXEMPT FROM THIS SECTION.
NET DEVELOPABLE ACREAGE = 139,614 SF - 3,900 SF = 135,714 SF = 3.16 ACRES P.C.C. 18J.15.040 - LANDSCAPE BUFFERS • BUILDING 'A' IS AN ASSISTED LIVING FACILITY LOCATION IN NON-RESIDENTIAL ZONING, THEREFORE EXEMPT
BASE DENSITY = 3.16 AC x 16 = 51 DWELLING UNITS; MAXIMUM DENSITY = 3.16 AC x 25 = 79 DWELLING UNITS MINIMUM LANDSCAPE LEVELS: FROM THE REQUIREMENTS OF P.C.C. 18J.15.185
SENIOR HOUSING to SINGLE FAMILY = L1: OFFICE, BUSINESS, COMMERCIAL, ARTERIAL = L2; S.H. TO MULTIFAMILY, CIVIC/UTILITY = L1
PROPOSED RESIDENTIAL DENSITY: COMMERCIAL TO OFFICE, BUSINESS = N/A; COMMERCIAL TO ARTERIAL = L2
BUILDING A: 79 DWELLING UNITS; SEE UNIT COUNT SUMMARY ON SHEET G003.
P.C.C. 18J.120.060 - SITE DESIGN
REGISTERED
STATE OF WASHINGTON
(118 TOTAL UNITS PROPOSED, 39 OF WHICH ARE NOT PROVIDED WITH FULL KITCHENS PER P.C.C. 18.25
ARCHITECT
LANDSCAPE LEVEL 1: CANOPY VEGETATION, VEGETATIVE SCREEN, BERM, SCREEN WIDTHS
TRAVIS McDANOLD
DEFINITIONS OF 'DWELLING UNIT') LANDSCAPE LEVEL 2: FILTERED SCREEN
OUTDOOR GATHERING SPACES MUST INCLUDE THE FOLLOWING: COURTS, PLAZAS, PATIOS, COVERED SPACES OR SEATING AREAS.
BUILDING B: 0 DWELLING UNITS • LANDSCAPE BUFFERS HAVE BEEN DEVELOPED ACCORDING TO REGULATIONS. SEE LANDSCAPE PLANS, SHEETS L3.0. SUCH SPACES SHALL NOT BE LESS THAN 10 PERCENT THE TOTAL FLOOR AREA OF THE MULTIPLE ON-SITE BUILDINGS.
(16 TOTAL RESIDENTIAL UNITS PROPOSED; AS DEFINED BY P.C.C. 18A.33.210 (D)(level5), THE MULTI-FAMILY
COMPONENT OF A MIXED USE DEVELOPMENT IS NOT RESTRICTED TO A SPECIFIC NUMBER OF UNITS PER • REQUIRED OUTDOOR GATHERING SPACE:
BUILDING OR DEVELOPMENT) GROSS BLDG AREA FOR BLDG A (EXCLUDING GARAGE): 119,775 SF
10635
GROSS BLDG AREA FOR BLDG B (EXCLUDING GARAGE): 52,139 SF
THE PROPOSED MAXIMUM DENSITY OF 25 DU/ACRE WILL BE ACHIEVED THROUGH THE PURCHASE OF TRANSFER P.C.C. 18J.15.050 - STREET TREES TOTAL GROSS BLDG AREA: 171,914 SF
OF DEVELOPMENT RIGHTS (TDR) CREDITS PER P.C.C. 18A.15.020(E)(1)(b). CREDITS TO BE PURCHASED PRIOR TO
ISSUANCE OF BUILDING PERMIT. STREET TREES PLANTED ALONG EACH SIDE OF STREET AT 1 PER 30 LINEAL FEET. CLUSTERING ALLOWED FOR DRIVEWAY PURPOSES. NO REQUIRED OUTDOOR SPACE = 10% 171,914 SF X .10 = 17,191 SF
MORE THAN 100FT BETWEEN TREE CLUSTERS. MIN. MATURE HEIGHT OF TREE TO BE 20'. TREES PLANTED WITH 5' OF ROADING PAVEMENT Revision Schedule
EDGE / CURB / SIDEWALK / PARKING SHOULD INCLUDE ROOT CONTROL BARRIER. • PROVIDED OUTDOOR GATHERING SPACE: (SEE SITE DIAGRAM FOR LOCATIONS, SHEET G007):
# DESCRIPTION DATE
SETBACK MEASUREMENT - ALL LOTS MUST HAVE ONE FRONT YARD AND ONE REAR YARD SETBACK. ALL OTHER
YARDS TO BE CONSIDERED INTERIOR YARD SETBACKS.
P.C.C. 18J.15.080 - OFF STREET PARKING P.C.C. 18J.120.070 - BUILDING DESIGN & PLACEMENT
MINIMUM BUILDING SETBACK FOR NEIGHBORHOOD COMMERCIAL: COMMERCIAL & OFFICE USES TO HAVE NO MORE THAN 50% OF REQUIRED PARKING STALLS BETWEEN ROAD AND BUILDING. BUILDINGS DESIGNED WITH GABLE, GAMBREL, FLAT, HIP, ROOF FORMS.
FRONT ARTERIAL= 20FT, FRONT NON ARTERIAL = 15FT, INTERIOR/SIDE = 0FT, REAR = 0FT
ROOFS VARIED BY USING GABLE ENDS AND OR DORMERS
• NO ON-GRADE PARKING IS PROPOSED IN LOCATIONS BETWEEN BUILDINGS AND PUBLIC RIGHT OF WAYS.
SETBACKS, TRANSITIONAL AREAS:
• THE ROOF DESIGN FOR BUILDING 'A' INCORPORATES A VARIETY OF GABLE, HIP, SHED AND FLAT ROOFS WITH DEEP
MULTIFAMILY & COMMERCIAL USES - NOT APPLICABLE.
SITE ENTRANCES NEED TO INCORPORATE SPECIAL DESIGN TREATMENTS SUCH AS DECORATIVE PAVEMENT, LANDSCAPING, LIGHTING, AND OVERHANGS. SEE SHEETS A207 (ROOF PLAN) AND A501 - A504 (EXTERIOR ELEVATIONS).
COMMERCIAL, SENIOR, OR ASSISTED LIVING FACILITIES - NOT APPLICABLE
ENTRY SIGN.
BUILDING DESIGNS MUST INCLUDE THE FOLLOWING: CORNICE DETAILS, TRIM DETAILS, KNEE BRACING
ZONING CODE
COMPLIANCE
SHARED ACCESS FACILITY - IF A SHARED ACCESS FACILITY IS USED TO PROVIDE VEHICLE ACCESS TO A NON-
• DECORATIVE PAVING, LANDSCAPING, LIGHTING AND SIGNAGE HAVE BEEN USED THROUGHOUT THE SITE, INCLUDING ENTRANCES.
NARRATIVE
RESIDENTIAL PROJECT, THE STRUCTURE SETBACK TO THE SHARED ACCESS FACILITY WILL BE ZERO.
SEE SITE PLAN, SHEET A101 AND LANDSCAPING PLANS, SHEETS L3.0. • BUILDING 'A' INCORPORATES BUILT-UP FASCIA TRIM AT ROOF RAKE EDGES AND EAVES, AND DECORATIVE BUILT-UP CORNICE
• ALL SETBACK LINES HAVE BEEN INDICATED ON SHEET A101 (SITE PLAN) DETAILING BETWEEN FLOORS 2 & 3, AS WELL AS DECORATIVE BELLY BANDING AND TRIM THROUGHOUT. KNEE BRACES ARE
GARAGE DOORS AND OPEN VEHICLE ENTRIES SHOULD BE RECESSED MIN. 6' FROM FRONT BUILDING FACADE. PROVIDED AT SELECT SHED ROOFS. SEE SHEETS A501 - A504 (EXTERIOR ELEVATIONS).
FENCES AND RETAINING WALLS WITHIN REQUIRED SETBACKS SHALL BE 6FT MAX HEIGHT.
• GARAGE DOOR/ENTRANCE HAS BEEN RECESSED MORE THAN 6' FROM FACADE. SEE A501-A504 (EXTERIOR ELEVATIONS). WINDOW DESIGN: WINDOW SILL AT LEAST 2' ABOVE INTERIOR FINISHED FLOOR, WINDOWS TO BE TRIMMED
• RETAINING WALLS ARE INDICATED ON ARCHITECTURAL SITE PLAN A101 & CIVIL GRADING PLANS. STANDARD PARKING STALL = 9' x 18'; COMPACT PARKING STALL = 8' x 16'
RETAINING WALLS LOCATED WITHIN SETBACKS OCCUR ON THE SOUTH SIDE AND NORTHEAST CORNER • ALL WINDOWS ARE PROVIDED WITH WINDOW TRIM OR ARE INCORPORATED INTO LARGER DECORATIVE ARCHITECTURAL
FOR NON-RESIDENTIAL DEVELOPMENTS, 40% OF PARKING ALLOWED TO BE COMPACT, EXCLUDING PARKING STALLS NEEDED TO MEET EXPRESSIONS. SEE SHEETS A501 - A504 (EXTERIOR ELEVATIONS).
OF THE PROPOSED PROJECT, AND DESIGNED NOT TO EXCEED 6' IN HEIGHT/ ACCESSIBILITY REQUIREMENTS.
PROJECTIONS - UNCOVERED DECKS AND PATIOS, <30" ABOVE FINISHED GRADE MAY PROJECT INTO ANY BUILDING MASS & SCALE:
• ALL PARKING STALLS MEET OR EXCEED MIN. SIZES. COMPACT STALLS WILL BE CLEARLY MARKED AS COMPACT. SEE SECTION MUST CONTAIN UNITY OF DESIGN THROUGH ROOF FORM, EXTERIOR BUILDING MATERIALS, COLORS, AND WINDOW STYLES
SETBACK, NOT TO EXTEND >5' INTO A FRONT SETBACK. 18A.35.040 THIS SHEET FOR PARKING REQUIREMENTS AND SITE PARKING INFO AND A201 FOR GARAGE PARKING PLAN.
WHEEL CHAIR RAMPS MAY PROJECT INTO ANY REQUIRED SETBACK. PARKING STRUCTURES TO MATCH THE MAIN BUILDINGS IN FORM, COLOR, MATERIALS, AND DETAILING
EAVE OVERHANGS ALLOWED TO PROJECT 2' INTO ANY SETBACK. LOADING AREAS SHALL BE LOCATED SO THAT TRUCKS USING THE SPACES DO NOT ENCROACH UPON OR INTERFERE WITH AREAS
ROOFTOP MECHANICAL EQUIPMENT ALLOWED TO PROJECT 10' ABOVE THE HEIGHT LIMIT OF THE ZONE; • BUILDINGS 'A' AND 'B' HAVE BEEN DESIGNED TO BE COMPLIMENTARY IN STYLING AND MATERIALS. BUILDING 'B' TO BE
RESERVED FOR OFF-STREET PARKING AND DO NOT PROJECT INTO ANY PUBLIC RIGHT-OF-WAY OR EASEMENT. IF THE LOADING SPACE IS SUBMITTED UNDER SEPARATE PERMIT.
PROVIDED ALL EQUIPMENT IS SET BACK 10' FROM THE EDGE OF THE ROOF. INCORPORATED WITHIN A BUILDING, THE LOCATION REQUIREMENTS OF THIS SUBSECTION SHALL NOT APPLY. REQUIRED LOADING AREAS
SHALL BE SHOWN ON THE PARKING PLAN AND BE PERMANENT IN NATURE MATERIALS PERMITTED:
• BLDG 'A' DOES NOT HAVE ANY DECKS, PATIOS OR EAVE OVERHANGS PROTRUDING INTO SETBACKS.
CONCRETE, WOOD-LOOKING MATERIALS (NO WOOD SHEETING), CONCRETE MASONRY UNITS, BRICK, METAL SIDING, AND OR STONE
CENTER
COMMERCIAL DEVELOPMENTS MUST PROVIDE MIN. (1) PEDESTRIAN CONNECTION TO EACH ADJACENT STREET. PEDESTRIAN FACILITIES
WITH HARD SURFACES TO BE CLEARLY MARKED WITH - PAVERS, STAMPED CONCRETE, OR RAISED MIN. 6" ABOVE ADJACENT SURFACE. • BUILDING 'A' IS DESIGNED TO COMPLIMENT THE ARCHITECTURAL CHARACTER OF THE BROWNS POINT NEIGHBORHOOD,
REQUIRED TO BE A DURABLE, NON SLIP SURFACE. WALKWAYS ADJACENT TO BUILDING, WALKWAYS THAT CONNECT ENTRIES TO STREET =
P.C.C. 18A.35.040 - PARKING 6' MIN. WIDTH
UTILIZING DECIDEDLY RESIDENTIAL FORMS AND MATERIALS CONSISTENT WITH COASTAL NORTHWEST ARCHITECTURE. THE
PRIMARY BUILDING ENTRANCE IS CELEBRATED WITH A GRAND PORTE COCHERE.
REQUIRED PARKING SPACES: • MULTIPLE PEDESTRIAN CONNECTIONS CONNECT THE OVERALL SITE TO ADJACENT STREETS AND ARE AT LEAST 6' IN WIDTH. SEE PROPOSED FEATURES – BUILDING ‘A’ (SENIOR LIVING COMMUNITY) (6 POINTS REQUIRED)
SHEET A101 (SITE PLAN). • (A) 18” MIN. SHIFT IN WALLS >80’ LENGTH, WIDTH OF SHIFT >30% OF WALL LENGTH 2
SENIOR HOUSING: 1 PER 2 BEDROOMS; APARTMENTS: STUDIO & 1 BR UNITS: 1.5 PER D.U.; 2BR UNITS: 2 PER DU • (C) SINGLE STAND OF TREES WITHIN 20' OF BUILDING FACADE 1
OFFICES: MIN: 2 PER 1,000 SF, MAX: 5 PER 1,000SF COMMERCIAL PROJECTS REQUIRE OUTDOOR PEDESTRIAN AMENITIES: BENCH OR SIMILAR SEATING TO BE PROVIDED AT A RATE OF- • (D) WINDOWS >30% OF WALL AREA, WALLS VISIBLE TO A PUBLIC ROADWAY 1
COMMERCIAL: MIN: 2 PER 1,000SF, MAX: 7 PER 1,000 SF 10-19 PARKING SPACES = 1 BENCH, 20-99 PARKING SPACES = 2 BENCHES OR 100-149 PARKING SPACES = 3 BENCHES • (F) DECORATIVE MASONRY, PILLARS OR COLUMNS, >10% OF WALL AREA 1
EATING & DRINKING ESTABLISHMENTS: MIN: 4 PER 1,000SF, MAX: 10 PER 1,000SF SEATING TO BE LOCATED: NEAR BICYCLE PARKING / BUILDING ENTRANCES, OUTSIDE OF PUBLIC RIGHT-OF-WAY, ADJACENT TO • (G) DECORATIVE PARAPET OR PROJECTING CORNICE 1
PEDESTRIAN WALKWAYS AND SIDEWALKS, ACCESSIBLE BY ALL
REQUIRED: PROPOSED FEATURES – BUILDING ‘B’ (MIXED USE RETAIL/APARTMENT) (6 POINTS REQUIRED)
• BENCHES HAVE BEEN PROVIDED AT VARIOUS AREAS ON SITE, SEE LANDSCAPING PLANS, SHEETS L3.0. • (A) 18” MIN. SHIFT IN WALLS >80’ LENGTH, WIDTH OF SHIFT >30% OF WALL LENGTH 2
BUILDING A - ASSISTED LIVING/MEMORY CARE:
1 STALL PER 2 BEDROOMS = 69 STALLS REQUIRED • (D) WINDOWS >30% OF WALL AREA, WALLS VISIBLE TO A PUBLIC ROADWAY 1
COMMERCIAL PROJECTS MUST PROVIDE OUTDOOR TRASH & RECYCLING. • (E) CANOPY, 5’ MIN. DEPTH, >10% OF WALL LENGTH 1
BUILDING B - MIXED USE: • (F) DECORATIVE MASONRY, PILLARS OR COLUMNS, >10% OF WALL AREA 1
• TRASH/RECYCLING RECEPTACLES HAVE BEEN PROVIDED AT VARIOUS AREAS ON SITE, SEE LANDSCAPING PLANS, SHEETS L1.0-L6.1. • (G) DECORATIVE PARAPET OR PROJECTING CORNICE 1
1 BEDROOM APARTMENTS = (9) x 1.5 = 14
2 BEDROOM APARTMENTS = (7) x 2.0 = 14 POINTS RELATING TO BUILDING WALL-RELATED DESIGN ONLY TO BE PROVIDED ALONG WALLS THAT ARE VISIBLE TO THE PUBLIC
ROADWAY.
RESTAURANT (UP TO 12,000 TOTAL GSF) =
COMMERCIAL/RETAIL =
12,000 @ 4/1000 = 48
15,000 @ 2/1000 = 30 P.C.C. 18J.15.090 - PARKING LOT LANDSCAPING
SUBTOTAL MIXED USE = 106 STALLS REQUIRED • SEE SHEET G007 FOR ANALYSIS OF DESIGN FEATURES
1. PERIMETER PARKING LOT LANDSCAPING REQUIRED FOR ANY PORTION OF PARKING LOT WITHIN 20' OF PUBLIC / PRIVATE ROAD RIGHT OF WAY
TOTAL REQUIRED PARKING = 175 STALLS 2. ALL NEW PARKING LOTS WITH 10 OR MORE SPACES REQUIRE INTERIOR PARKING LOT LANDSCAPING BUILDING PLACEMENT:
35' MAX. HEIGHT ABOVE EXISTING GRADE OR ELEVATION OF EASTSIDE DRIVE. NO STRUCTURE TO EXCEED 60' MAX. HEIGHT.
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
PROPOSED: STANDARDS:
PLANTINGS TO BE PROTECTED BY CURBS, WHEEL STOPS, ECT.; 10 PARKING SPOTS IN A ROW ALLOWED BETWEEN LANDSCAPE ISLANDS • BUILDING HEIGHT MAXIMUMS ARE INDICATED ON SHEETS A501 - A504 (EXTERIOR ELEVATIONS) & A601 - A603 (BUILDING
BUILDING A BUILDING B LANDSCAPE AREAS TO BE 64SF MIN., NO LESS THAN 6' MIN DIMENSION; TREES SETBACK MIN. 24" FROM CURB. SECTIONS). EITHER BOTH OR THE MOST RESTRICTIVE HEIGHT LIMITATION IS INDICATED.
NORTH SURFACE LOT: OFFSTREET SURFACE:
STANDARD 31 ADA 3 PERIMETER PARKING LOT LANDSCAPING: STREET CORNER EMPHASIZED THROUGH: ACCENT LANDSCAPING, ACCENT PAVING, INFORMAL SEATING AREAS, PEDESTRIAN
COMPACT 13 L2 BUFFER ALONG RIGHT OF WAY WHENEVER PARKING IS WITHIN 20' OF PUBLIC ROAD RIGHT OF WAY. PERIMETER STREET LANDSCAPING FOR BOLLARDS, WALKWAY LIGHTING
STANDARD 7 PARKING LOT DOES NOT COUNT TOWARD TOTAL INTERIOR LANDSCAPING. LOCATE BUILDING ENTRANCE ON CORNER
A G006
SEE SHEETS A501 - A504 (EXTERIOR ELEVATIONS).
• BLDG 'A' HAS BEEN DESIGNED TO FOLLOW THE SLOPE OF THE LAND WITH MINIMAL RETAINING WALLS • BUILDING 'B' IS LOCATED ACROSS A SHARED INTERNAL DRIVE AISLE, AND THEREFORE A COVERED WALKWAY CONNECTION IS
NECESSARY. SEE A101 (SITE PLAN) AND LANDSCAPE PLANS L1.0-L6.1. NOT PRACTICAL.
t: 425-453-0606
www.wattenbarger.com
ROOF DECK:
LIVING ROOM: RECREATIONAL ACTIVITIES: DINING,
RECREATIONAL ACTIVITIES: SOCIAL ENGAGEMENT, VIEWING OF
INDEPENDENT READING, SOCIAL THEATER: PUGET SOUND
SALON:
ENGAGEMENT WITH FRIENDS & FAMILY, RECREATIONAL ACTIVITIES: VIEWING RECREATIONAL ACTIVITIES: HAIRCUTS,
SMALL GATHERINGS FOR OUTSIDE MOVIES AND TELEVISION SHOWS, GUEST MAIN DINING ROOM:
MEMORY CARE THEATER PERSONAL CARE, INCLUDING PEDICURE
PERFORMERS (I.E. PIANO RECITALS, SPEAKERS AND PRESENTATIONS RECREATIONAL ACTIVITIES: DINING,
RECREATIONAL ACTIVITIES: AND MANICURE
POETRY READING, ETC.) SOCIAL ENGAGEMENTS, LARGE GROUP
WATCHING MOVIES SPEAKING AND PRESENTATION EVENTS
BELLEVUE, WA 98004
Active recreation Passive recreation Active recreation Active recreation
347 SF 614 SF 397 SF 505 SF
Passive recreation
Active recreation
3,607 SF
REGISTERED
STATE OF WASHINGTON
ARCHITECT
1,039 SF Passive recreation
TRAVIS McDANOLD
Active recreation
Passive recreation 333 SF PRIVATE DINING ROOM:
569 SF RECREATIONAL ACTIVITIES: DINING,
1,311 SF
MEMORY CARE Passive recreation SMALL SOCIAL ENGAGEMENTS/SPECIAL
DINING/ACTIVITY ROOM: Active recreation EVENTS WITH FRIENDS AND FAMILY
687 SF
10635
RECREATIONAL ACTIVITIES:
DINING AT MEAL PERIODS, 882 SF
STAFF ASSISTED ACTIVITIES LIBRARY: BAR:
BETWEEN MEAL PERIODS RECREATIONAL ACTIVITIES: RECREATIONAL ACTIVITIES: DRINKING,
(ARTS/CRAFTS, COGNITIVE READING, SMALL GROUP SOCIAL ENGAGEMENT
STIMULATION ACTIVITIES) CAFE BISTRO: BIBLE/RELIGIOUS STUDY
Revision Schedule
RECREATIONAL ACTIVITIES:
EATING, SOCIALIZING WITH # DESCRIPTION DATE
SPORTS DEN:
FRIENDS AND FAMILY, READING
RECREATIONAL ACTIVITIES:
MEMORY CARE PATIO NEWSPAPER / MAGAZINES
BILLIARD TABLE FOR GAMES
RECREATIONAL ACTIVITIES: AND RESIDENT
STAFF ASSISTED GARDENING TOURNAMENTS,
ACTIVITY ROOM: POKER/CARD TABLE FOR
RECREATIONAL ACTIVITIES: STAFF CARD GAMES, TELEVISION
ORGANIZED ARTS/CRAFTS/CLASSES, VIEWING
MEDIUM-SIZE GROUP GATHERINGS INDOOR RECREATIONAL AREA TOTALS
FOR OUTSIDE PERFORMERS AND
SPEAKERS, SOCIAL CLUB MEETINGS Name Area
ZONING CODE
RESISTANCE SWIMMING, SMALL Active recreation 569 SF
COMLIANCE
GROUP WATER AEROBICS, MOBILITY
DIAGRAMS
Active recreation 882 SF
EXERCISES Active recreation 1905 SF
Active recreation 347 SF
EXERCISE ROOM: Active recreation 1039 SF
Active recreation RECREATIONAL ACTIVITIES: Active recreation 5643 SF
CARDIOVASCULAR AND Passive recreation 3607 SF
1,905 SF BALANCE- ORIENTED EXERCISE Passive recreation 333 SF
Passive recreation 614 SF
Passive recreation 687 SF
Passive recreation 1311 SF
Passive recreation 284 SF
Passive recreation 6836 SF
12479 SF
CENTER
1103 SF 1103 SF
31 PARKING STALLS
LE-LOU-WA PLACE N.E.
CORNER PLAZA
2024 SF OUTDOOR GATHERING SPACE
PASSIVE REC. AREA
3842 SF SITE RECREATION AREAS MEMORY CARE PATIO: 1,103 SF
DINING ROOF DECK SIDEWALK CAFE: 1,040 SF
PASSIVE RECREATION AREA 1158 SF
6,556 SF PLAZA
PASSIVE RECREATIONAL AREAS: 2927 SF CORNER PLAZA: 2,024 SF
INDOOR 12,724 DINING ROOF DECK: 1,158 SF
OUTDOOR 17,321 PLAZA: 2,927 SF
TOTAL 30,045 ROOFTOP PLAZA: 1,981 SF
PASSIVE REC AREA ROOFTOP PLAZA
APT. ENTRY: 528 SF
1981 SF 1981 SF
ACTIVE RECREATIONAL AREAS: RETAIL PLAZA: 17,861 SF
INDOOR 3,414
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
PASS. REC
PLOT DATE
1/22/2021 11:48:38 AM
DATE: 01/22/21
SCALE: As indicated
DRAWN: TM
CHCKD: TM
LANDSCAPE BUFFER SEPARATING RECREATION
EAST SIDE DRIVE N.E. (S.R. 509) EAST SIDE DRIVE N.E. (S.R. 509)
SPACE FROM RIGHT OF WAY ADJACENCY
BLDG. SHEET NO.:
NORTH NORTH
2
G007
PCC 18J.15.180 - RECREATIONAL AREAS - SITE DIAGRAM
1" = 40'-0"
3
G007
OUTDOOR GATHERING SPACES - SITE DIAGRAM
1" = 40'-0"
A G007
t: 425-453-0606
www.wattenbarger.com
11000 N.E. 33RD PL., SUITE #102
BELLEVUE, WA 98004
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
ZONING CODE
COMPLIANCE
DIAGRAMS
(A) WALL MODULATION: P.C.C. 18J.120.070(B)(2) - Building Design and Placement - Architectural Elements
50' - 0" 108' - 0 1/2" REQUIRED:
BUILDING SIZE: >40,000 SF; 6 POINTS REQUIRED
MIN. MODULATION (30%): 32'-5"
PROVIDED MODULATION: 48'-5" PROPOSED:
2' - 0"
• (A) 18” MIN. SHIFT IN WALLS >80’ LENGTH, WIDTH OF SHIFT >30% OF WALL LENGTH 2 • (F) DECORATIVE MASONRY, PILLARS OR COLUMNS, >10% OF WALL AREA 1
(C) STAND ADJACENT
6' - 0"
TO PRIMARY
SEE SITEPLAN DIAGRAM BELOW SHOWING LOCATIONS AND APPLICABILITY OF PER PCC 18J.120.070(B)(2)(A)(2), BUILDING WALL-RELATED DESIGN FEATURE,
OF 3 TREES
2' - 2"
48' - 5 1/2" EXTERIOR WALL SHIFTS THE DESIGN FEATURE NEED ONLY BE PROVIDED ALONG THE WALL(S) THAT WILL ENTRANCE
BE VISIBLE TO THE PUBLIC ROADWAY IN ORDER FOR THE POINT TO BE EARNED.
32' - 3 1/2"
• (D) WINDOWS >30% OF WALL AREA, (WALLS VISIBLE TO A PUBLIC ROADWAY) 1 • (G) PITCHED ROOF WITH FASCIA, DECORATIVE PARAPET OR PROJECTING CORNICE 1
(FACADE <80')
SEE SOUTH AND WEST ELEVATION DIAGRAMS BELOW. WHILE THE WEST ENTIRE ROOF PERIMETER IS COMPRISED OF EITHER PITCHED ROOFS WITH OVER-
9' - 10"
ELEVATION IS NOT ADJACENT TO A PUBLIC RIGHT OF WAY, IT'S PROMINENCE HANGING EAVE AND FASCIA (RAKE FASCIAS COMPRISED OF 2-PIECE BUILT-UP AREA: 370 SF
PLANTING
62' - 0"
CENTER
AND HEIGHT SUGGEST IT WILL BE VISIBLE FROM THE SOUTH AND WEST DUE PLANS FOR FULL
LOWER EXISTING BUILDING HEIGHTS ADJACENT TO THE PROJECT. THE TOP FLOOR DINING ROOM). PLANTING
DIAGRAM INFORMATION
1' - 8 1/2"
10' - 1"
5' - 0"
35' - 0"
17' - 3 1/2"
15' - 2" 15' - 2" (D) WINDOW AREA >30% (D) WINDOW AREA >30%
(G) PROJECTING
82'-1 1/2"
87'-2"
CORNICE DETAILS FLAT OR GABLE ROOFS ROOF VARIED WITH GABLES WITH FASCIA
AND DORMERS
WITH FASCIA
273' - 9"
60'-3"
69'-7"
5' - 0"
35' - 0"
35' - 0"
DECORATIVE
KNEE BRACE
PROVIDED MODULATION:
(BEYOND)
MIN. MODULATION (30%):
200' - 9"
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
BUILDING DESIGN
DETAILS:
KNEE BRACES,
TYP.
21802.1
4' - 0"
OPEN OPEN
PLOT DATE
DECORATIVE MASONRY
2' - 0"
1/22/2021 11:48:57 AM
PILLARS / COLUMNS, TYP.
BUILDING DESIGN DETAILS: BUILDING DESIGN DETAILS:
DECORATIVE CORNICE
WINDOW TRIM WINDOW SILLS AT GROUND DATE: 01/22/21
AT PODIUM,DEFINING
A STRONG ARCHITECTURAL
LEVEL 2' ABOVE FLOOR
(F) MASONRY, PILLARS SCALE: As indicated
BASE
(F) PILLARS OR COLUMNS >10% OR COLUMNS >10% DRAWN: LR
25' - 0"
WEST FACADE AREA: 14,119 SF CHCKD: TM
74' - 6" SOUTH FACADE AREA: 3,694 SF
TOTAL PILLARS/COL. AREA: 2,063 SF (14.6%) TOTAL MAS/PIL/COL. AREA: 448 SF (12.1%)
MIN. MODULATION (30%): 82'-1 1/2" BLDG. SHEET NO.:
PROVIDED MODULATION: 87'-2"
WEST ELEVATION SOUTH ELEVATION
(NOT ADJ. TO R.O.W., BUT VISIBLE DUE TO HEIGHT) A G008
t: 425-453-0606
www.wattenbarger.com
OCCUPANCY
CLASS.
SF PER
OCC.
TOTAL
OCC.
LEVEL EXITING REQUIREMENTS
NAME AREA OCCUPANCY USE
GROUND FLOOR LEVEL:
PARKING 16,272 SF S-2 Parking Garages 200 82
BELLEVUE, WA 98004
STAFF AREAS 2,356 SF B Business Areas 100 24
SHAFT & EXIT ENCL 140 SF B (none) 0 MINIMUM EGRESS STAIR WIDTH PER 2015 I.B.C. SECTION 1005 AND
SHAFT & EXIT ENCL 70 SF B (none) 0 CALCULATED OCCUPANT LOAD:
SHAFT & EXIT ENCL 70 SF B (none) 0
SHAFT & EXIT ENCL 91 SF B (none) 0
[ 112 OCCUPANTS x .20" ] = 22.4" TOTAL REQUIRED WIDTH.
20,666 SF 112
22.4" / 2 EXITS = 11.2" MINIMUM EACH
EGRESS STAIR TO BE 44.5" MIN. WIDTH, THEREFORE OK
EGRESS STAIR TO BE 48" AT ACCESSIBLE ROUTE, THEREFORE OK
(The loss of any one means of egress does not reduce the available capacity to less
REGISTERED
STATE OF WASHINGTON
ARCHITECT
than 50 percent of the required capacity.)
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
UTILITY RMS
EXITING − BASEMENT
SQUARE FT OCC. LOAD
688 3
OCCUPANCY &
O.L.F. FUNCTION
300 S-2
OCCUPANY CLASSIFICATION
B
STAFF AREAS
SQUARE FT OCC. LOAD S-2
2,356 24
O.L.F. FUNCTION
100 B
44" REQ.
45"
UP
23'
34'
56 OCC
PARKING
SQUARE FT OCC. LOAD
16,272 82
O.L.F. FUNCTION
CENTER
200 S-2
28
STORAGE 9' -
31
SQUARE FT OCC. LOAD /2"
789 3
O.L.F. FUNCTION
300 S-2
DN
(MIN 222'
REQ -13
'D: 2 /4"
89.2
48' 5' / 3
=9 6.4')
20' 126'
15'
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
3'
56 OCC
PLOT DATE
1/22/2021 11:49:02 AM
49"
ACCESSIBLE ROUTE DATE: 01/22/21
SCALE: 3/32" = 1’−0"
DRAWN: DH/SC/LR
CHCKD: TM
1
G009
OCCUPANCY & EXITING PLAN - BASEMENT
3/32" = 1'-0"
A G009
t: 425-453-0606
www.wattenbarger.com
FIRE SEPARATION LINE
BELLEVUE, WA 98004
42' - 10"
FIRE SEPARATION DISTANCE
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
30' - 3 1/2"
FIRE SEPARATION DISTANCE
FI
MAINT.
R
E
SE
014 WTR.
10635
PA
HTRS.
R
AT
015
IO
LAUNDRY
N
LI
013
N
E
NR Revision Schedule
NR
# DESCRIPTION DATE
PASSAGE
011 TELECOM. FIRE SEPARATION LINE
LIFE SAFETY
UP P
43' - 0"
BASEMENT
90 P S3
DIAGRAM −
S4
SH
S3
VESTIBULE S5 SC2
010 2SH P
P
LOBBY PARKING
005 ENTRY
004
ELEV.
P P
EQP.
UP STORAGE 002
007 90
FP 45
FEC-2
SVC. S6
LOBBY
006 ELEC. FP
001
CENTER
FP
PARKING
000
2SH FEC-1
90 P
S3
S4 15' - 1 1/2"
FIRE SEPARATION
2SH STAIR 3 DISTANCE
ST003
UP
SP
FIRE SEPARATION
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
15' - 0 1/2"
DISTANCE
BELLEVUE, WA 98004
B 1ST FLOOR SMOKE 1ST FLOOR SMOKE
COMP. A COMP. B
I-1 10,967 SF 9,425 SF
REGISTERED
STATE OF WASHINGTON
ARCHITECT
168 SF
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
COMPARTMENT B
REFUGE AREA:
273 SF
RES - NORTH
SQUARE FT OCC. LOAD
4,375
EXITING − FIRST
37
OCCUPANCY &
O.L.F.
120
FUNCTION
I-1
2 SMOKE COMPARTMENT PLAN - 1ST FLOOR
G011 3/64" = 1'-0"
25'
FLOOR
51' TRAVEL DISTANCE (250' MAX.) THEATER OCCUPANCY SF PER TOTAL
SQUARE FT
394
OCC. LOAD
27 LEVEL EXITING REQUIREMENTS NAME AREA CLASS. OCCUPANCY USE OCC. OCC.
O.L.F. FUNCTION
15 A-3 FIRST FLOOR: POOL ABV. 497 SF S-2 (none) 0
POOL EQUIP. 304 SF S-2 Accessory Storage Areas, Mechanical Equipment Room 300 2
SHAFT & EXIT ENCL
MINIMUM REQUIRED NUMBER OF EXITS PER 2015 I.B.C SECTION RES - NORTH 4,375 SF I-1 Institutional - Sleeping Areas 120 37
374 OCC / 2 = 187 26' SQUARE FT OCC. LOAD SHAFT & EXIT ENCL 131 SF I-1 (none) 0
187 x .2" = 37.4 MIN WIDTH 89 1006 AND CALCULATED OCCUPANT LOAD:
RES - WEST 7,445 SF I-1 Institutional - Sleeping Areas 120 63
O.L.F. FUNCTION
2 EXITS REQUIRED (3 EXITS PROVIDED) SHAFT & EXIT ENCL 229 SF I-1 (none) 0
0 B
SHAFT & EXIT ENCL 89 SF B (none) 0
MINIMUM EGRESS STAIR WIDTH PER 2015 I.B.C. SECTION 1005 SHAFT & EXIT ENCL 89 SF B (none) 0
44" REQ.
CIRCULATION
4'
SQUARE FT OCC. LOAD AND CALCULATED OCCUPANT LOAD: SHAFT & EXIT ENCL 88 SF B (none) 0
45"
DN 1,220 13
MED/CONSULT 1,421 SF B Business Areas 100 15
SHAFT & EXIT ENCL
O.L.F.
100
FUNCTION
B [ 430 OCCUPANTS x .20" ] = 86.0" TOTAL REQUIRED WIDTH. SERVERY/SERVICE AREA 905 SF B Business Areas 100 10
SQUARE FT OCC. LOAD 86.0" / 3 EXITS = 28.7" MINIMUM EACH RESTROOMS 191 SF B Business Areas 100 2
131 CIRCULATION 1,220 SF B Business Areas 100 13
EGRESS STAIR TO BE 44.5" MIN. WIDTH, THEREFORE OK
CENTER
SHAFT & EXIT ENCL
SQUARE FT OCC. LOAD O.L.F. FUNCTION O.L.F. FUNCTION
89 15 A-3 100 B
O.L.F. FUNCTION
0 B POOL EQUIP.
SQUARE FT OCC. LOAD
25' 304 2
O.L.F. FUNCTION
( MI 205 300 S-2
NR '-4
EQ 1/2"
'D: 2
99.7
5' /
3=
121' TRAVEL DISTANCE (250' MAX.) 99.9
') POOL ABV.
SQUARE FT OCC. LOAD
33' 497
O.L.F. FUNCTION
OPEN TO BELOW 33+17=50 0 S-2
SEE G008
14'
33+18=51
12'
(250' MAX)
SERVERY/SERVICE AREA
DN
SQUARE FT OCC. LOAD
905 10
DATE: 01/22/21
EXIT
SCALE: As indicated
DRAWN: DH/SC/LR
DINING MC PATIO ACTIVITY RES - WEST SHAFT & EXIT ENCL
SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD CHCKD: TM
986 66 1,044 70 330 23 7,445 63 229
O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION BLDG. SHEET NO.:
15 A-2 15 A-3 15 A-3 120 I-1 0 I-1
1
G011
OCCUPANCY & EXITING PLAN - FIRST FLOOR
3/32" = 1'-0"
A G011
t: 425-453-0606
www.wattenbarger.com
FIRE SEPARATION LINE
REGISTERED
STATE OF WASHINGTON
ARCHITECT
FP
TRAVIS McDANOLD
UNIT MC4
111 20
ACCESSIBLE
20
FI
20
R
E
20
10635
SE
PA
R
AT
UNIT 20
IO
N
FP MC2−b CORR
LI
CORR
N
110
E
Revision Schedule
ANSI TYPE ’B’ CORR
# DESCRIPTION DATE
FEC-1
45
P MH
UNIT MC2
109 CORR THEATER
ANSI TYPE ’B’ 115
35' - 7"
CE
DIAGRAM FIRST
S4
2SH
LIFE SAFETY
20 2SH
2SH 2SH
UNIT MC6
FLOOR
108
ANSI TYPE ’B’ S5
SMP SMP
2SH
CORR EL. LBY. 45
2SH
101 WOMEN
CE
116
SMP FEC-1
CENTER
2SH 45 45
CORR 20 20 45
S1 20 20
SERVERY FEC-1
FEC-2 2SH 126 P SB
FEC-1
45
SB
CORRIDOR CORR
FEC-1
MH
CORR CORR 122 20
LOADING DINING SB
CORR
148 125 2SH 20
ACTIVITY FP
20 20 20 20 20 20 20 20 CE S3 CORR
123
SB 90 20
P DN
FP
DN 2SH UNIT MC4
S3 137
P S3 P ACCESSIBLE
STAIR 3
FP FP FP 2SH
ST103 UNIT
UNIT UNIT UNIT UNIT MC4−b
S2 MC1−b UNIT MC1 MC1−b UNIT MC1 MC1−b UNIT MC1 MC1−b UNIT MC1 138
139 15' - 2 1/2"
MC PATIO 146 145 144 143 142 141 140 ACCESSIBLE
ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’ UP FIRE SEPARATION DISTANCE
124 ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’
FIRE SEPARATION DISTANCE
S3
P
SP
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
15' - 10"
A G012
FROM THE LANDING WHEN THE DOOR IS IN THE OPEN AND CLOSED POSITION.
1 1ST FLOOR LIFE SAFETY PLAN
G012 3/32" = 1'-0"
t: 425-453-0606
www.wattenbarger.com
REFUGE AREAS:
REQUIRED: 15 SF PER CARE RECIPIENT + 6 SF PER OTHER OCCUPANT (GUESTS & CAREGIVERS)
CARE RECIPIENT COUNT BASED ON 1 RESIDENT PER BEDROOM
COMPARTMENT A: COMPARTMENT B:
(15) CARE OCCUPANTS AT 15 SF = 225 SF (10) CARE OCCUPANTS AT 15 SF = 150 SF
OCCUPANY CLASSIFICATION (8) STAFF/VISITORS AT 6 SF = 48 SF (8) STAFF/VISITORS AT 6 SF = 48 SF
BELLEVUE, WA 98004
A-3 2ND FLOOR SMOKE 2ND FLOOR SMOKE
COMP. A COMP. B
14,882 SF 8,970 SF
B
COMPARTMENT B
REFUGE AREA:
I-1 198 SF COMPARTMENT B TRAVEL COMPARTMENT A
DISTANCE: 110' (MAX 200') REFUGE AREA:
COMPARTMENT A TRAVEL 273 SF
DISTANCE: 172' (MAX 200')
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
EXITING − SECOND
G013 3/64" = 1'-0"
OCCUPANCY &
EXIT
SHAFT & EXIT ENCL
SQUARE FT OCC. LOAD
LEVEL EXITING REQUIREMENTS OCCUPANCY SF PER TOTAL
FLOOR
188 NAME AREA CLASS. OCCUPANCY USE OCC. OCC.
SECOND FLOOR:
O.L.F. FUNCTION
0 I-1 SHAFT & EXIT ENCL 188 SF I-1 (none) 0
MINIMUM REQUIRED NUMBER OF EXITS PER 2015 I.B.C SECTION 1006 AND SHAFT & EXIT ENCL 87 SF I-1 (none) 0
CALCULATED OCCUPANT LOAD: SHAFT & EXIT ENCL 74 SF I-1 (none) 0
LIVING
SQUARE FT OCC. LOAD
3 EXITS REQUIRED (3 EXITS PROVIDED) SHAFT & EXIT ENCL 95 SF I-1 (none) 0
18 OCC 635 43 SHAFT & EXIT ENCL 245 SF I-1 (none) 0
MINIMUM EGRESS STAIR WIDTH PER 2015 I.B.C. SECTION 1005 AND RES - WEST 6,269 SF I-1 Institutional - Sleeping Areas 120 53
O.L.F. FUNCTION
15 A-3 RES - NORTH 7,867 SF I-1 Institutional - Sleeping Areas 120 66
CALCULATED OCCUPANT LOAD:
ADMIN SUITE 1,070 SF B Business Areas 100 11
POOL 1,114 SF A-3 Swimming Pool 50 23
[ 603 OCCUPANTS x .20" ] = 120.6" TOTAL REQUIRED WIDTH. ACTIVITY 916 SF A-3 Assembly Unconcentrated (tables and chairs) 15 62
18 OCC
120.6" / 3 EXITS = 40.2" MINIMUM EACH LIVING 635 SF A-3 Assembly Unconcentrated (tables and chairs) 15 43
EGRESS STAIR TO BE 44.5" MIN. WIDTH, THEREFORE OK LOBBY 1,428 SF A-3 Assembly Concentrated (chairs only - not fixed) 7 204
SHAFT & EXIT ENCL
SQUARE FT OCC. LOAD EXERCISE AREA 1,054 SF A-3 Exercise Rooms 50 22
(MI 205
87 N RE (The loss of any one means of egress does not reduce the available capacity to less MAIL AREA 685 SF A-3 Assembly Unconcentrated (tables and chairs) 15 46
Q' D ' - 8 3
than 50 percent of the required capacity.)
')
29
9' POOL
-7
1/8 SQUARE FT OCC. LOAD
LOBBY BISTRO " 1,114 23
SHAFT & EXIT ENCL
SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD 103' TRAVEL DISTANCE O.L.F. FUNCTION
CENTER
1,428 204 907 61 (250' MAX)
SQUARE FT OCC. LOAD 50 A-3
74 O.L.F. FUNCTION O.L.F. FUNCTION
7 A-3 15 A-2
O.L.F. FUNCTION
0 I-1
35 OCC
23 OCC
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
30 OCC
30 OCC
21 OCC
PLOT DATE
1/22/2021 11:49:43 AM
DATE: 01/22/21
SCALE: As indicated
RES - NORTH ADMIN SUITE ACTIVITY RES - WEST SHAFT & EXIT ENCL EXERCISE AREA
SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD DRAWN: DH/SC/LR
SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD
7,867 787 1,070 11 916 62 6,269 63 245 1,054 22 CHCKD: TM
O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION
10 I-1 100 B 15 A-3 100 I-1 0 I-1 50 A-3
BLDG. SHEET NO.:
1
G013
OCCUPANCY & EXITING PLAN - SECOND FLOOR
3/32" = 1'-0"
A G013
t: 425-453-0606
www.wattenbarger.com
FIRE SEPARATION LINE
REGISTERED
STATE OF WASHINGTON
ARCHITECT
251 ANSI TYPE ’B’ BLDG A - 2ND FLOOR 22,863 SF 4500 6 6
TRAVIS McDANOLD
ANSI TYPE ’B’ CORR BLDG A - 3RD FLOOR 24,542 SF 4500 6 6
BLDG A - 4TH FLOOR 24,073 SF 4500 6 6
20
BLDG A - 5TH FLOOR 22,002 SF
FP
FI
R
E
20 CORR
10635
SE
2SH
PA
R
AT
IO
N
UP S3
2SH
LI
N
UNIT A1 STAIR 2 P
E
S3 S4 Revision Schedule
250 FEC-1 90 P ST202
ANSI TYPE ’B’ SP # DESCRIPTION DATE
20
2SH
20
UNIT A1 FIRE SEPARATION LINE
FP
CORR LIVING
249
ANSI TYPE ’B’ ROOM
203
FP
DIAGRAM SECOND
CORR
LIFE SAFETY
43' - 9 1/2"
UNIT A1
248
FLOOR
ANSI TYPE ’B’
20
FEC-1
S5
30' - 0" 20 2SH
P
FIRE SEPARATION DISTANCE 60
FP 2SH VEST.
UNIT A1 S5 201
247 P
ANSI TYPE ’B’
CORR S3
LOBBY S2
CORR 202
FP IDF/ELEC.
UNIT A1 245
246 RECEPTION FP
BISTRO /
ANSI TYPE ’B’ 45 205 FIREPLACE SB FP
20 CORR. PUB FP FP
ALCOVE
CENTER
FP 244 P MH FP CORR
CORR 45 211 213 45 S1
45 FEC-1 20 20
S1 45
20 FEC-1
UNIT C9 20 CORR SHOWER
243 P MH 2SH TOILET
CORR CORR MKTG
MAIL S1 45 SB
CORR
FEC-1
CORRIDOR CORR S4 S3
CORR 219 220 S1
ANSI TYPE ’B’ FEC-1 CORR CORR
20
238 209 CORR 212 90
P WOMEN STAIR 3 P
MECH.
FP 20 222
20 20 210 20 20 20 20 20 ST203 EQP.
45 221
BUS. S2
P SB FP 2SH UP
MGR. FP
FP
CONF. 233 DN 2SH
237 SB
2SH
15' - 10"
BELLEVUE, WA 98004
REFUGE AREA:
273 SF 3RD FLOOR SMOKE
COMP. B
3RD FLOOR SMOKE
COMP. A 11,030 SF
14,141 SF
COMPARTMENT B TRAVEL COMPARTMENT A
COMPARTMENT A TRAVEL
DISTANCE: 124' (MAX 200') REFUGE AREA:
DISTANCE: 163' (MAX 200')
303 SF
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
RESIDENTIAL - NORTH
SQUARE FT OCC. LOAD
11,303 95
O.L.F. FUNCTION
2 SMOKE COMPARTMENT PLAN - 3RD FLOOR
120 I-1 G015 3/64" = 1'-0"
EXITING − THIRD
OCCUPANCY &
SHAFT & EXIT ENCL
112 OCC
SQUARE FT OCC. LOAD
LEVEL EXITING REQUIREMENTS OCCUPANCY SF PER TOTAL
FLOOR
148 NAME AREA CLASS. OCCUPANCY USE OCC. OCC.
O.L.F. FUNCTION THIRD FLOOR:
0 I-1
SHAFT & EXIT ENCL 148 SF I-1 (none) 0
MINIMUM REQUIRED NUMBER OF EXITS PER 2015 I.B.C SECTION 1006 AND SHAFT & EXIT ENCL 91 SF I-1 (none) 0
CALCULATED OCCUPANT LOAD: SHAFT & EXIT ENCL 181 SF I-1 (none) 0
2 EXITS REQUIRED (3 EXITS PROVIDED) SHAFT & EXIT ENCL 67 SF I-1 (none) 0
SHAFT & EXIT ENCL 67 SF I-1 (none) 0
MINIMUM EGRESS STAIR WIDTH PER 2015 I.B.C. SECTION 1005 AND RESIDENTIAL - SOUTH 10,563 SF I-1 Institutional - Sleeping Areas 120 89
(M RESIDENTIAL - NORTH 11,303 SF I-1 Institutional - Sleeping Areas 120 95
I N R 203' - CALCULATED OCCUPANT LOAD:
EQ 53 SHAFT & EXIT ENCL 24 SF I-1 (none) 0
'D : /8
300 " SHAFT & EXIT ENCL 26 SF I-1 (none) 0
'/3
=1
[ 303 OCCUPANTS x .20" ] = 60.6" TOTAL REQUIRED WIDTH. LEISURE AREAS 1,966 SF A-3 Assembly Unconcentrated (tables and chairs) 15 132
00'
) 60.6" / 3 EXITS = 20.2" MINIMUM EACH SHAFT & EXIT ENCL 106 SF A-3 (none) 0
SHAFT & EXIT ENCL EGRESS STAIR TO BE 44.5" MIN. WIDTH, THEREFORE OK 24,542 SF 315
SQUARE FT OCC. LOAD
67
(The loss of any one means of egress does not reduce the available capacity to less
O.L.F. FUNCTION
than 50 percent of the required capacity.)
CENTER
SQUARE FT OCC. LOAD 30
67 0'
- 1"
O.L.F. FUNCTION
0 I-1
45 OCC
112 OCC 45 OCC
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
HORIZONTAL EXIT
89 OCC / 2 = 45
45 x .2" = 9" MIN WIDTH
PLOT DATE
1/22/2021 11:50:12 AM
DATE: 01/22/21
SCALE: As indicated
223 OCC / 2 = 112 or DRAWN: DH/SC/LR
89 OCC / 2 = 45
112 x .2" = 22.4" MIN WIDTH CHCKD: TM
1
G015
OCCUPANCY & EXITING PLAN - THIRD FLOOR
3/32" = 1'-0"
A G015
t: 425-453-0606
www.wattenbarger.com
FIRE SEPARATION LINE
FP
UNIT C1
306
ANSI TYPE ’B’
REGISTERED
STATE OF WASHINGTON
ARCHITECT
UNIT C1
TRAVIS McDANOLD
30' - 2" 307
FIRE SEPARATION DISTANCE FP ANSI TYPE ’B’
20
FI
R
E
2SH
SE
10635
PA
20
R
AT
IO
90 P UP
N
LI
CORR STAIR 2
N
E
20 S3
S4 ST302 SP
2SH Revision Schedule
DN
UNIT B3
305 FEC-1
# DESCRIPTION DATE
CORR. UNIT B5
302 308
ACCESSIBLE
CORR
2SH
UNIT B3
DIAGRAM THIRD
304 20
LIFE SAFETY
ANSI TYPE ’B’ 2SH
2SH
FLOOR
FP 2SH
FP
S5 FP LIBRARY
S2
2SH 309
MH
SC1 ELEV.
P 2SH LOBBY
CORR
S5 301
20 2SH
UNIT B3 2SH SC3
303 FP
ANSI TYPE ’B’
IDF/ELEC. FP 2FB
FP
339
FP
CORR 2SH UNIT B6
FP
SMP 323
UNIT B1 FP
UNIT B1 UNIT B1 ANSI TYPE ’B’
45 S2
316 UNIT B1 320 321
ANSI TYPE ’B’ 317 UNIT B2 ANSI TYPE ’B’ ANSI TYPE ’B’ FP
2SH
FP 2SH CORR 45 FP
2SH 2SH
UNIT B7
CENTER
P MH
45 20 20 20 20 20
20 20 20 324
UNIT C2 ANSI TYPE ’B’
337 FEC-1 CORR. P MH
SP CORR FEC-1
20 CORR CORR 2SH 313 CORR CORR SP FEC-1 90 CORR
CORR
FEC-1 CORR 2SH CORR 20
ANSI TYPE ’B’
S3
20 20 20 20 90 FP
20 20 20 20 20 20 S4 20 20
STAIR 3 DN P
FP CORR
2SH ST303 2SH
UP
SP
FP
15' - 0"
F04
A G016
FROM THE LANDING WHEN THE DOOR IS IN THE OPEN AND CLOSED POSITION.
1 3RD FLOOR LIFE SAFETY PLAN
G016 3/32" = 1'-0"
t: 425-453-0606
www.wattenbarger.com
REFUGE AREAS:
REQUIRED: 15 SF PER CARE RECIPIENT + 6 SF PER OTHER OCCUPANT (GUESTS & CAREGIVERS)
CARE RECIPIENT COUNT BASED ON 1 RESIDENT PER BEDROOM
COMPARTMENT A: COMPARTMENT B:
(18) CARE OCCUPANTS AT 15 SF = 270 SF (15) CARE OCCUPANTS AT 15 SF = 225 SF
(8) STAFF/VISITORS AT 6 SF = 48 SF (8) STAFF/VISITORS AT 6 SF = 48 SF
COMPARTMENT B
BELLEVUE, WA 98004
REFUGE AREA:
B 273 SF
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
109 OCC / 2 = 55
55 x .2" = 22.4" MIN WIDTH
EXITING − FOURTH
SQUARE FT OCC. LOAD
G017 3/64" = 1'-0"
OCCUPANCY &
149
55 OCC
O.L.F. FUNCTION
RESIDENTIAL - NORTH
0 I-1
SQUARE FT OCC. LOAD
FLOOR
12,417 104
O.L.F.
120
FUNCTION
I-1
LEVEL EXITING REQUIREMENTS
FOURTH FLOOR: OCCUPANCY SF PER TOTAL
NAME AREA CLASS. OCCUPANCY USE OCC. OCC.
MINIMUM REQUIRED NUMBER OF EXITS PER 2015 I.B.C SECTION 1006 AND
RESIDENTIAL - SOUTH 10,581 SF I-1 Institutional - Sleeping Areas 120 89
CALCULATED OCCUPANT LOAD:
SHAFT & EXIT ENCL 163 SF I-1 (none) 0
2 EXITS REQUIRED (3 EXITS PROVIDED) SHAFT & EXIT ENCL 67 SF I-1 (none) 0
SHAFT & EXIT ENCL 67 SF I-1 (none) 0
MINIMUM EGRESS STAIR WIDTH PER 2015 I.B.C. SECTION 1005 AND SHAFT & EXIT ENCL 91 SF I-1 (none) 0
(M 203
CALCULATED OCCUPANT LOAD: SHAFT & EXIT ENCL 149 SF I-1 (none) 0
I NR '-5
EQ RESIDENTIAL - NORTH 12,417 SF I-1 Institutional - Sleeping Areas 120 104
'D : 3 /8
SHAFT & EXIT ENCL 300 " [ 198 OCCUPANTS x .20" ] = 39.6" TOTAL REQUIRED WIDTH. SHAFT & EXIT ENCL 25 SF I-1 (none) 0
'/3
SQUARE FT
67
OCC. LOAD
=1 39.6" / 3 EXITS = 13.2" MINIMUM EACH SHAFT & EXIT ENCL 26 SF I-1 (none) 0
00' SALON 488 SF B Business Areas 100 5
) EGRESS STAIR TO BE 44.5" MIN. WIDTH, THEREFORE OK
O.L.F. FUNCTION 24,073 SF 198
0 I-1
CENTER
67 - 1"
O.L.F. FUNCTION
0 I-1
SALON
SQUARE FT OCC. LOAD
488 5
O.L.F. FUNCTION
100 B
45 OCC
55 OCC 45 OCC
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
89 OCC / 2 = 45
45 x .2" = 9" MIN WIDTH
PLOT DATE
1/22/2021 11:50:44 AM
DATE: 01/22/21
SHAFT & EXIT ENCL RESIDENTIAL - SOUTH SHAFT & EXIT ENCL SCALE: As indicated
SQUARE FT OCC. LOAD 109 OCC / 2 = 55 or SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD
DRAWN: DH/SC/LR
91 89 OCC / 2 = 45 10,581 89 62' TRAVEL DISTANCE 163
55 x .2" = 11" MIN WIDTH (250' MAX) CHCKD: TM
O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION
0 I-1 120 I-1 0 I-1
BLDG. SHEET NO.:
1
G017
OCCUPANCY & EXITING PLAN - FOURTH FLOOR
3/32" = 1'-0"
A G017
t: 425-453-0606
www.wattenbarger.com
FIRE SEPARATION LINE
UNIT C1
406
REGISTERED
STATE OF WASHINGTON
ARCHITECT
ANSI TYPE ’B’
TRAVIS McDANOLD
UNIT C1
FP
407
ANSI TYPE ’B’
20
FI
R
E
2SH
10635
SE
PA
20
R
AT
IO
P
N
90 UP
LI
STAIR 2
N
CORR S3
E
Revision Schedule
S4
DN ST402 SP
UNIT B3 2SH
# DESCRIPTION DATE
405 FEC-1
ANSI TYPE ’B’ CORR
FP 2SH
20 FIRE SEPARATION LINE
CORR.
402 UNIT B5
408
ACCESSIBLE
CORR
DIAGRAM FOURTH
CORR 2SH
UNIT B3
404 20
LIFE SAFETY
ANSI TYPE ’B’ CORR 2SH 2SH
FP
FLOOR
FP
60
S5
MH
2SH SC1 ELEV.
P LOBBY
2SH S5
60 401
CORR
20 2SH 2SH
FEC-1
UNIT B3
403 IDF/ELEC 2FB
FP
ANSI TYPE ’B’ 439 SB UNIT B6
2SH 423
FP SB
UNIT B1 UNIT B1 FP UNIT B1 UNIT B1 FP ANSI TYPE ’B’
45 416 417 420 421
FP ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’
SVC./HKPG. SALON UNIT B2 FP
2SH
17
CORR 2SH 45
'-
CENTER
2SH
11
45 P MH UNIT B7
5/ 8
20 20 20 20 20 20 20 20 20
UNIT C2 424
"
SP
437 FEC-1 CORR CORR.
P MH
CORR. CORR 2SH FEC-1
ANSI TYPE ’B’
20 CORR CORR SP FEC-1 90 CORR CORR FEC-1 20
ANSI TYPE ’B’ CORR 2SH CORR
CORR 413 414 S3
20 20 20 20 20 20 20 20 20 90 20 FP
20 20
S4
DN P
FP 2SH
FP
STAIR 3 2SH
SP UP ST403
FP
UNIT B2 UNIT B8
FP
UNIT B2 UNIT B2 FP UNIT B2 429 FP 2SH 425
434 433 430 ANSI TYPE ’B’ FP ANSI TYPE ’B’
FP ANSI TYPE ’B’
UNIT B1 ANSI TYPE ’B’ UNIT B1 UNIT B1 ANSI TYPE ’B’ UNIT B1 UNIT B1b
UNIT C3 435 432 431 FP
428 427
436 UNIT B9
ANSI TYPE ’B’ FP ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’ 426
ACCESSIBLE
SB ANSI TYPE ’B’
FP FP
2FB FP
FP
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
A G018
FROM THE LANDING WHEN THE DOOR IS IN THE OPEN AND CLOSED POSITION.
1 4TH FLOOR LIFE SAFETY PLAN
G018 3/32" = 1'-0"
t: 425-453-0606
www.wattenbarger.com
REFUGE AREAS:
REQUIRED: 15 SF PER CARE RECIPIENT + 6 SF PER OTHER OCCUPANT (GUESTS & CAREGIVERS)
CARE RECIPIENT COUNT BASED ON 1 RESIDENT PER BEDROOM
COMPARTMENT A: COMPARTMENT B:
OCCUPANY CLASSIFICATION (8) CARE OCCUPANTS AT 15 SF = 120 SF (16) CARE OCCUPANTS AT 15 SF = 225 SF
(8) STAFF/VISITORS AT 6 SF = 48 SF (8) STAFF/VISITORS AT 6 SF = 48 SF
COMPARTMENT B
A-3
BELLEVUE, WA 98004
REFUGE AREA:
288 SF
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
10635
Revision Schedule
# DESCRIPTION DATE
EXITING − FIFTH
SHAFT & EXIT ENCL
OCCUPANCY &
SQUARE FT OCC. LOAD G019 3/64" = 1'-0"
149
168 OCC
O.L.F. FUNCTION
FLOOR
OCCUPANCY SF PER TOTAL
0 I-1
LEVEL EXITING REQUIREMENTS NAME AREA CLASS. OCCUPANCY USE OCC. OCC.
RESIDENTIAL - NORTH
SQUARE FT OCC. LOAD FIFTH FLOOR: RESIDENTIAL - NORTH 3,628 SF I-1 Institutional - Sleeping Areas 120 31
3,628 31 RESIDENTIAL - SOUTH 10,097 SF I-1 Institutional - Sleeping Areas 120 85
O.L.F. FUNCTION MINIMUM REQUIRED NUMBER OF EXITS PER 2015 I.B.C SHAFT & EXIT ENCL 162 SF I-1 (none) 0
120 I-1
SECTION 1006 AND CALCULATED OCCUPANT LOAD: SHAFT & EXIT ENCL 67 SF I-1 (none) 0
SHAFT & EXIT ENCL 2 EXITS REQUIRED (3 EXITS PROVIDED) SHAFT & EXIT ENCL 67 SF I-1 (none) 0
SQUARE FT OCC. LOAD SHAFT & EXIT ENCL 149 SF I-1 (none) 0
67 RESIDENTIAL - NORTH 2 1,275 SF I-1 Institutional - Sleeping Areas 120 11
MINIMUM EGRESS STAIR WIDTH PER 2015 I.B.C. SECTION
O.L.F. FUNCTION
1005 AND CALCULATED OCCUPANT LOAD: SHAFT & EXIT ENCL 21 SF I-1 (none) 0
0 I-1 SHAFT & EXIT ENCL 24 SF I-1 (none) 0
82' TRAVEL DISTANCE SHAFT & EXIT ENCL 108 SF B (none) 0
(250' MAX)
MEN'S RM [ 427 OCCUPANTS x .20" ] = 85.4" TOTAL REQUIRED SERVICE 589 SF B Accessory Storage Areas, Mechanical Equipment Room 300 2
SQUARE FT OCC. LOAD (M WIDTH.
164 2 I N R 203' MEN'S RM 164 SF B Business Areas 100 2
EQ -5
'D: 3/ 85.4" / 3 EXITS = 28.5" MINIMUM EACH
SHAFT & EXIT ENCL O.L.F. FUNCTION 298 8" WOMEN'S RM 179 SF B Business Areas 100 2
100 B '/3 EGRESS STAIR TO BE 44.5" MIN. WIDTH, THEREFORE OK
CENTER
O.L.F. FUNCTION
100 B
KITCHEN
SQUARE FT OCC. LOAD
1,314 7
O.L.F. FUNCTION
200 A-2
D= 3 5 43 OCC
(MIN R ' - 2 5/8
EQ'D: "
102.75 168 OCC
'/3 = 34 43 OCC
.25')
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
9 5/8"
102' -
85 OCC / 2 = 43
43 x .2" = 8.6" MIN WIDTH
PLOT DATE
1/22/2021 11:51:10 AM
DATE: 01/22/21
ROOF DECK DINING/PUB PRIVATE DINING RESIDENTIAL - NORTH 2 RESIDENTIAL - SOUTH SHAFT & EXIT ENCL SCALE: As indicated
SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD SQUARE FT OCC. LOAD
265 18 2,633 176 292 20 1,275 11 10,097 85 162 DRAWN: DH/SC/LR
335 OCC / 2 = 168 or 62' TRAVEL DISTANCE
O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION O.L.F. FUNCTION 85 OCC / 2 = 43 (250' MAX) O.L.F. FUNCTION O.L.F. FUNCTION CHCKD: TM
15 A-3 15 A-2 15 A-2 120 I-1 168 x .2" = 33.6" MIN WIDTH 120 I-1 0 I-1
BLDG. SHEET NO.:
1
G019
OCCUPANCY & EXITING PLAN - FIFTH FLOOR
3/32" = 1'-0"
A G019
t: 425-453-0606
www.wattenbarger.com
FIRE SEPARATION LINE
REGISTERED
STATE OF WASHINGTON
ARCHITECT
30' - 2" UNIT C1
TRAVIS McDANOLD
FIRE SEPARATION DISTANCE 507
ANSI TYPE ’B’
FP
20
FI
R
E
CORR 2SH
SE
10635
PA
20
R
AT
IO
N
90
LI
STAIR2
N
E
20 S3
S4
DN ST502 Revision Schedule
UNIT B3 2SH SP
505 FEC-1
CORR. # DESCRIPTION DATE
DIAGRAM FIFTH
LIFE SAFETY
2SH 2SH MEN
503
FLOOR
60 S1
2SH S5
SC1 ELEV.
LOBBY
2SH S5
60 501
2SH
2SH
SBKIT. OFF.
2FB
FP 532 2SH FP
SB FP
ELEC./IDF S2 FP UNIT B6
45 533 523
LOBBY PRIVATE FP
PB 45
530 DINING UNIT B1 UNIT B1 FP UNIT B1 UNIT B1 ANSI TYPE ’B’
SB
509 516 517 520 521
SB
ANSI TYPE ’B’ ANSI TYPE ’B’ UNIT B2 ANSI TYPE ’B’ ANSI TYPE ’B’
17
2SH FP
'-
2SH
538 510
11
2SH 2SH
FP
5/ 8
9' - 1"
FP 2SH MECH. S1
CENTER
"
PB 45 535 UNIT B7 FIRE SEPARATION DISTANCE
20 20 20 20 20 20 20 20
D= 3
524
FP 5' - 2 3 P MH P MH SP ANSI TYPE ’B’
FP SERVERY 2SH
(MIN R
EQ'D /4" FEC-1 CORR. 90 CORR CORR CORR. FEC-1 CORR CORR FEC-1 CORR 20
= 102 45
537 '-9 1/2
"/3= 513b 514 2SH
3 4'-4") S3
20 20 20 20 90 20
FEC-1 S2 DN S4 FP
P
STAIR 3
SP 2SH 2SH
F09
ST503
9 1/2"
102' - UNIT C4
2SH
527 UNIT C11 SP
FP UNIT A2 UNIT C4 FP ANSI TYPE ’B’ 526 UNIT C5
MAIN PUB 529 528 ANSI TYPE ’B’ 525
DINING 512 ANSI TYPE ’B’ 2FB ANSI TYPE ’B’
FP
ACCESSIBLE
511 FP
SB
STOR.
512A
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
2FB 2-HR FIRE BARRIER, AND HORIZONTAL EXIT PER 2015 IBC 1026 Electric locking systems shall be permitted to be locked in the means of egress in Group I-1, provided that the doors are installed and operate in accordance 21802.1
& 707. PROTECT ALL OPENINGS. SMP 1-HR SMOKE PARTITION PER IBC 710. PROTECT ALL OPENINGS. MH DOOR WITH MAGNETIC HOLD OPEN with all of the following:
S6 SIGN INDICATING LOCATION OF ELECTRICAL ROOM
1. The doors unlock upon actuation of the automatic sprinkler system or automatic fire detection system. PLOT DATE
ILLUMINATED EXIT SIGN TD ELEVATOR HOISTWAY PROTECTION PER 3006.3 - TOTAL DOOR 2. The doors unlock upon loss of power controlling the lock or lock mechanism.
2SH 2-HR FIRE BARRIER, EXIT ENCLOSURE OR SHAFT PER 2015 S7 SIGN INDICATING LOCATION OF SPRINKLER RISER ROOM 1/22/2021 11:51:17 AM
3. The door locking system shall be installed to have the capability of being unlocked by a switch located at the fire command center, a nursing station or other
IBC 707. PROTECT ALL OPENINGS. FEC FIRE EXTINGUISHER AND CABINET, SEE FLOOR PLANS FOR SIGNS ON DOORWAYS TO SANITARY FACILITIES: SYMBOLS TO BE 1/4" THICK,
S1 approved location. The switch shall directly break power to the lock.
ADDITIONAL INFORMATION. '3-A-40-BC' MIN. RATING (4-A-80-BC LOCATED ON LATCH SIDE OF DOOR, 60" HIGH, IN CONTRASTING COLOR. SEE S8 SIGN INDICATING LOCATION OF FIRE ALARM CONTROL PANEL
FEC-2 4. A building occupant shall not be required to pass through more than one door equipped with a controlled egress locking system before entering an exit.
AT GARAGE). FEC = RECESSED FEC-2 = SURFACE MOUNT DETAIL. DATE: 01/22/21
SH 5. The procedures for unlocking the doors shall be described and approved as part of the emergency planning and preparedness required by Chapter 4 of the
1-HR FIRE BARRIER, EXIT ENCLOSURE OR SHAFT PER 2015 SC1 1 HR SMOKE CURTAIN PER IBC 715.4C W/ VISION PANEL PER ASME 17.1
FEC-K International Fire Code. SCALE: As indicated
IBC 1023 & 707. PROTECT ALL OPENINGS. FIRE EXTINGUISHER AND CABINET, SEE FLOOR PLANS FOR S2 SIGN WITH MAXIMUM ROOM CAPACITY; SEE OCCUPANT LOAD TABLES FOR 6. There is a system, such as a keypad and code, in place that allows visitors, staff persons and appropriate residents to exit. Instructions for exiting shall be
ADDITIONAL INFORMATION. CLASS K RATING (KITCHEN) ACTUAL MAXIMUM TOTAL OCCUPANT LOAD PER ROOM SC2 90 MIN. SMOKE CURTAIN AT ELEVATOR HOISTWAY DOOR, TESTED IN DRAWN: DH/SC/LR
CORR postedwithin six feet of the door. All clinical staff shall have the keys, codes or other means necessary to operate the locking systems.
ACCORDANCE WITH UL 1784, PER IBC 3006.3 EXCEPTION #3
SP S3 7. Emergency lighting shall be provided at the door. CHCKD: TM
STANDPIPE PER IBC 905 TACTILE SIGN, RAISED LETTERS, AND BRAILLE STATING "EXIT" PER IBC 1013.4
1-HR CORRIDOR PER IBC TABLE 1020.1 SC3 8. The door locking system units shall be listed in accordance with UL 294.
3 HR HORIZONTAL SMOKE CURTAIN PER IBC 715.4C
P Exception:
FP PANIC HARDWARE EQUIPPED EXIT DEVICE SIGNAGE LOCATED WITHIN STAIRWELL INDICATING FLOOR LEVEL AND BLDG. SHEET NO.:
1. Items 1 through 4, and 6 shall not apply to doors to areas where persons, which because of clinical needs, require restraint or containment as part of the
1-HR FIRE PARTITION PER IBC 708.1. PROTECT ALL OPENINGS. S4 DIRECTION TO THE EXIT DISCHARGE. +5' AFF SUCH THAT IT IS READILY VISIBLE function of a psychiatric treatment area provided that all clinical staff shall have the keys, codes or other means necessary to operate the locking devices. NORTH
PB DOOR WITH PUSH BUTTON OPENERS ON BOTH SIDES FROM THE LANDING WHEN THE DOOR IS IN THE OPEN AND CLOSED POSITION.
1
G020
5TH FLOOR LIFE SAFETY PLAN
3/32" = 1'-0"
A G020
t: 425-453-0606
www.wattenbarger.com
AIR BARRIER
A continuous air barrier shall be provided throughout the building thermal envelope.
AIR BARRIER & THERMAL ENVELOPE AIR BARRIER & THERMAL ENVELOPE PENETRATIONS
AIR BARRIER & THERMAL ENVELOPE AT FLOOR AIR BARRIER & THERMAL ENVELOPE AT FLOOR Penetrations of the air barrier and paths of air leakage shall be caulked , gasketed or otherwise sealed in a manner compatible with the
AIR BARRIER PRESSURE construction materials and location. Joints and seals shall be sealed in the same manner or taped or covered with a moisture vapor-
BOUNDARY & THERMAL AIR BARRIER & THERMAL ENVELOPE AT CEILING/ROOF AIR BARRIER & THERMAL ENVELOPE AT CEILING/ROOF
ENVELOPE (WALLS) permeable wrapping material. The joints and seals shall be securely installed in or on the joint for its entire length so as not to dislodge,
AIR BARRIER PRESSURE WALL ENVELOPE: 998' X 10' = 9,980 SF loosen or otherwise impair its ability to resist positive and negative pressure from wind, stack effect and mechanical ventilation.
WALL ENVELOPE: (342' + 64') X 10' = 4,060 SF BOUNDARY & THERMAL
GROUND FLOOR
BELLEVUE, WA 98004
CONCRETE WALL AREA = 161' X 9.25' = 1,489 SF WOOD WALL AREA = (998' X 10') - 2,475 SF = 7,505 SF
342' LTGA WALL PERIMETER = 181' AIR BARRIER PRESSURE SLAB EDGE INS. = 998' X 1' = 998 SF
LTGA WALL AREA = (181' X 9.25') - 158 SF = 1,516 SF BOUNDARY & THERMAL
AIR BARRIER PRESSURE ENVELOPE (WALLS) RECESSED LIGHTING
CONDITIONED SLAB PERIMETER = 342'
BOUNDARY & THERMAL Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned
ENVELOPE (FLOOR) spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate of not more than 2.0 cfm (0.944 L/s) when tested
in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk
R-10 PERIMETER SLAB INSULATION
3RD FLOOR between the housing and interior wall or ceiling covering.
Area:
25,171 SF PREPARATION OF THE BUILDING
Perimeter: Contractor is responsible for sealing or otherwise effectively isolating all "intentional" holes in the test boundary.
REGISTERED
STATE OF WASHINGTON
ARCHITECT
998'
TRAVIS McDANOLD
OPEN PARKING GARAGE
GROUND FLOOR AIR BARRIER PRESSURE BUILDING TEST
(UNCONDITIONED) STAIR 3 BOUNDARY & THERMAL The completed building shall be tested and the air leakage rate of the building envelope shall not exceed 0.40 cfm/ft2 at a pressure
Area: ENVELOPE (FLOOR)
233 SF differential of 0.3 inches water gauge (2.0 L/s ·m2 at 75 Pa) at the upper 95 percent confidence interval in accordance with ASTM E 779 or
Perimeter:
an equivalent method approved by the code official.
64'
10635
A visual inspection of the air barrier shall be conducted including Infrared Thermography and/or theatrical smoke application to determine air
leakage paths and deficiencies during the Building test. Inspection shall be performed under pressurization or depressurization in general
R-10 SUBSLAB INSULATION conformance with ASTM E 1186.
(CONTINUOUS)
BOUNDARY & THERMAL volume, stories above grade, leakage rates and observed air leakage pathways. # DESCRIPTION DATE
ENVELOPE (WALLS)
Observed air leakage pathways noted in the Testing Agency report shall be sealed to the extent practicable. An additional report identifying
1 BLDG A - BASEMENT 4 BLDG A - 3RD FLOOR the corrective actions taken to seal air leaks shall be submitted by the contractor to the building owner & Code Official.
G021 1/32" = 1'-0" G021 1/32" = 1'-0"
Contractor will be liable for costs of removal of finishes and/or cladding required to provide corrections to the air barrier system.
BARRIER
211' PERIMETER
WALL ENVELOPE: 928' X 10.75' = 9,976 SF WALL ENVELOPE: 1,005' X 10' = 10,050 SF 4TH FLOOR 10,050 2,261
FLOOR ENVELOPE: 15,176 SF CEILING ENVELOPE: 2,261 SF
AIR BARRIER PRESSURE 3RD FLOOR 9,980 1,554
BOUNDARY & THERMAL CONCRETE WALL PERIMETER = 299'
CONCRETE WALL AREA = 299' X 10' = 2,990 SF WOOD WALL AREA = (1,005' X 10') - 2,578 SF = 7,472 SF
ENVELOPE (WALLS)
LTGA WALL PERIMETER = 629 SF 2ND FLOOR 10,892 3,181 437
AIR BARRIER PRESSURE LTGA WALL AREA = (629' X 10') - 1,329 SF = 4,961 SF
SLAB EDGE INS. = 928' X .75' = 696 SF AIR BARRIER PRESSURE BOUNDARY
BOUNDARY & THERMAL & THERMAL ENVELOPE (WALLS) 1ST FLOOR 9,976 15,176
ENVELOPE (FLOOR)
15,176 SF
BASEMENT 4,060 5,192
(CONDITIONED)
CENTER
AIR BARRIER PRESSURE BOUNDARY &
THERMAL ENVELOPE (CEILINGS) 2,261 SF WINDOWS DOORS
2 BLDG A - 1ST FLOOR 5 BLDG A - 4TH FLOOR LEVEL FIXED AWNING SINGLE HUNG SLIDING DOOR REGULAR SPECIAL TOTAL OPENINGS
G021 1/32" = 1'-0" G021 1/32" = 1'-0"
5TH FLOOR 822 166 1,212 90 23 128 2,441
ZONING: NC
DENTAL DASH POINT FIRE FOUPLEX FOUPLEX FOUPLEX
OFFICE DEPARTMENT
S.F. RESIDENCE PARCEL APN 4700003031 PARCEL APN 4700003032 PARCEL APN 4700003033
PARCEL APN 4700002980 PARCEL APN 4700002970 ZONING: NC ZONING: NC ZONING: NC
ZONING: NC ZONING: NC
PARCEL APN 4700003010
ZONING: NC
BELLEVUE, WA 98004
N 0° 28' 12" E 334.31'
[ 0' BSBL ] L1 LSCP BUFFER
L2 LSCP BUFFER
MEMORY CARE PATIO
PARCEL APN 75750000021 RAMP DOWN
[ 0' BSBL ]
L2 LSCP BUFFER
24' - 0"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
31 PARKING STALLS
BUILDING A
TRAVIS McDANOLD
- 0"
110'
10635
MECH. SPRINKLER RISER ROOM
113' - 0" HOUSE- 5 STORIES OVER BASEMENT PARKING TRASH
XFRMR.
KEEPING E.GEN.
GARAGE (37 STALLS) 26' - 0" FH
+co
SD
PAD D.S.
LE-LOU-WA PLACE N.E.
FDC 106
114' - 0" DN "
'-0 L2 LSCP BUFFER Revision Schedule
PIV
SIDEWALK CAFE AT BISTRO N 0° 25' 52" W 180.03' # DESCRIPTION DATE
FH
LIGHT WELL BELOW
115' - 0"
D.S. D.S.
107' - 0"
COLLECTOR ARTERIAL
1 16 '
- 0"
08 ' - 0" 1
1 17
'-0
"
D.S - 0"
118 1 09 '
"
'-0 C C C C C C C C C C DM
120' - 0"
118' - 0"
119
120 ' -
"
'-0
110
'-
1 19
ARCHITECTURAL
'-0
0"
WM
0"
"
26' - 0"
0" '-
SITE PLAN
12 111
0'
-0
"
D.S
+co
SD
0"
12 2' -
1' 11
-0
"
0"
12 3' -
2' 11
-0
"
D.S -0
N 89° 05' 12" W 230.26'
123' - 0"
D.S. 11
4'
D.S D.S
ST MATTHEWS
1 24 ' -
PARCEL APN 0321167005 PARCEL APN 0321167004
EPISCOPAL
0"
ZONING: NC ZONING: NC
0"
CHURCH
'- 5
D.S
11
LIGHT WELL BELOW
DN.
20' BSBL
FH
125
'-0
"
D.S
0"
6' - BROWNS POINT
126' - 0" 11
PARCEL APN
"
26' - 0"
1 27' -
-0
"
0" -0 0"
8' '-
9'
11 117
11
D.S
CENTER
129' - 0" C C C
FH
BUILDING B 119' - 0"
132' - 0"
FH
124' - 0"
D.S
SUBMITTED UNDER SEPARATE PERMIT
133' - 0"
125' - 0"
S
36
° 21
128' - 0"
'2
1"
W
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
131' - 0"
13
8'
-
MEEKER 0"
S 0° 34' 24" E 332.87' 132' - 0"
MEMORIAL 9' -
13
XFRMR. FH
PLOT DATE
EAST SIDE DRIVE N.E. (S.R. 509) 1/22/2021 1:04:07 PM
MINOR ARTERIAL (URBAN) 132.94' (*)
136.60' (*) 133.95' (*) 133.66' (*) 133.26' (*)
DATE: 01/22/21
139.41' (*) 138.32' (*)
SCALE: 1" = 20’−0"
142.33' (*)
DRAWN: TM/GD
CHCKD: TM
(*) SPOT ELEVATIONS MEASURED AT EAST SIDE DRIVE CENTER STRIPE PER SITE SURVEY BY P.S.S.
BLDG. SHEET NO.:
1
A101
OVERALL SITE PLAN
1" = 20'-0"
A A101
t: 425-453-0606
www.wattenbarger.com
42" ALUM. GUARDRAIL 1-1/2" GALV. STEEL TUBE
BEYOND HANDRAIL, EACH SIDE OF STAIR.
SECURE TO CONC. STAIR ON
GRADE WITH GROUT POCKETS
OR BASEPLATES
BELLEVUE, WA 98004
MAX. 48" TALL MODULAR
RETAINING WALLS SPOT ELEVATION
AT TOP PER CIVIL
3' - 0"
1' - 0"
REGISTERED
STAIR LANDING,
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
MAX. 2% SLOPE
FOR 48" MIN.
BEYOND FIRST RISER
N 1° 16' 58" E 148.08'
CAST IN PLACE METAL STAIR NOSING,
CONTRASTING COLOR (ALT. PAINTED
10635
5' - 0" C.I.P. CONCRETE SIDEWALK, TYP.
SPOT TOOLED GROOVES AT LEADING EDGE)
ELEVATION
12" TREAD (11" MIN.), 7" MAX. RISER,
4' - 0"
AT BOTTOM
PER CIVIL SLOPE TREAD SURFACE 2% TO DRAIN
Revision Schedule
5' - 7"
4' - 10"
C.I.P. CONCRETE STAIR ON GRADE, REFER # DESCRIPTION DATE
TO STRUCTURAL FOR MIN. THICKNESS,
REINFORCEMENT REQUIREMENTS, AND FOOTING 1
2' - 1"
r=
9'
MODULAR BLOCK
-
C.I.P. CONCRETE SIDEWALK, TYP.
0"
RETAINING WALL,
MAX. 48" HEIGHT
CONC. HOUSEKEEPING PAD
ALUM. GUARDRAIL,
FOR POOL DEHUMIDIFIER
6' - 0"
MANUFACTURER PRIOR TO
12"
6" 4' - 0"
r=
5' - 6"
AT FORMING
10
EA 0"
'-
DS
TR 11' -
0"
+co
SD
- 0"
6' - 0" 5' - 0" 6' - 0" 8' - 10 1/8" 9' - 4"
DRIVEWAY APRON PER CIVIL
51'
MIN. MIN.
AND COUNTY PUBLIC WORKS
r=
8' - 5"
2 ADA
65
.0
A102 STALL
°
CENTER
SIGNAGE
4 LIGHTWELL BELOW, SEE ALSO
0"
5' - 7"
13' - 0"
-
7' - 7"
6' 6' - 0" 8' - 0" 6' - 0"
r=2
MIN. MIN.
- 0"
4'
6' - 0"
6" FIRE HYDRANT
6' - 0"
FLUSH CURB
6"
" C.I.P. CONC. RETAINING WALL
' -0
N 89° 05' 12" W 230.26'
r = 26' -
2' - 0"
6"
TRUNCATED DOME
TRUNCATED DOME DETECTABLE FLUSH CURB
0"
" DETECTABLE WARNING SURFACE
16' - 0"
16' - 0"
-0 3' - 2 5/8" WARNING SURFACE
0"
'
13 H AL
T NC.
'-
ASP CO
20
8' - 6" 8' - 6" 8' - 6" 8' - 6" 11' - 0" 8' - 6" 8' - 6" 8' - 6" 8' - 6" 8' - 6" 8' - 6" 9' - 0" 5' - 0" 9' - 0"
r=
COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT COMPACT
18
' -0
"
ASPHALT CONC.
1
13' - 0"
13' - 0"
CONC. ASPHALT A901
6'
-
0"
r = 10' - 0" FLUSH
0"
EQ EQ EQ EQ
'-
CURB
16
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
r = 10' - 0"
CONCRETE WITH INTEGRAL
COLOR ADDITIVE - COLOR 'A', r = 26
' - 0"
COLOR TO BE SELECTED BY
2'
AS
ARCHITECT
N
-
PH
0"
AL
0"
NC.
T
'-
10
20
CO
' -0
CO
T
HAL
"
ASP
2'
- 0"
JOB NO.:
CO
N
21802.1
C.
0"
'-
AS
13
PH
PLOT DATE
AL
T
1/22/2021 1:04:14 PM
DATE: 01/22/21
0"
'-
13
SCALE: As indicated
DRAWN: TM
CHCKD: TM
1
A102
PARTIAL SITE PLAN - SOUTH
1" = 10'-0"
A A102
t: 425-453-0606
www.wattenbarger.com
A
5' - 0" 8' - 0" 10' - 4" 81' - 0" 8' - 0" 81' - 0"
9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 4' - 0" 9' - 0 1/2"
N 0° 28' 12" E 334.31'
TRUNCATED DOME
7' - 0 3/4"
DETECTABLE
C.I.P. CONCRETE SIDEWALK, TYP. WARNING SURFACE
4' - 0"
BELLEVUE, WA 98004
1
18' - 0"
19' - 6" 10' - 0" 14' - 6"
0"
MEMORY CARE PATIO
'-
20
10.0% DN. 17.9% DN. 10.0% DN. CONC.
r=
r=
ASPHALT
0'
-
10
"
CROSSWALK
5' - 0" PAINTED
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
24' - 0"
24' - 0"
EXTENT OF
STORMWATER
DETENTION VAULT
CONTROL JOINTS,
10635
TYPICAL 11' - 0 1/8"
CONC.
PAINTED STRIPING ASPHALT
TRUNCATED DOME
r=1
DETECTABLE
Revision Schedule
WARNING SURFACE
8' -
# DESCRIPTION DATE
FLUSH CURB
0"
18' - 0"
0"
'-
10
r=
TRASH ROOM
SPRINKLER RISER
FIRE HYDRANT
F 9' - 0" 9' - 0" 9' - 0" 9' - 0"
FDC 26' - 0" 29' - 0 1/8" 36' - 0" 8' - 0" 81' - 0"
8 TREADS AT 12"
3/
PIV
8"
5' - 8 3/4"
8' - 0"
N 0° 25' 52" W 180.03'
NORTH
4
45.
UP
0°
- 0"
r = 58'
FLUSH CURB
4
5' - 6" 10"
r = 26' -
8 TREADS @ 12"
8"
H AL
T NC. 2
7/
ASP CO 2'
2
8'
-0
'-
-
"T A103
28
5
1/
YP CONCRETE
2"
3' - 0"
IC WALKWAY
AL
3' - 0"
5
1/
9 RISERS @ 6.66"
0"
CENTER
5' - 0"
CONCRETE WITH INTEGRAL
r = 10' - 0"
"
PATTERN AS INDICATED.
0
- 0"
8' -
TYPICAL AS INDICATED BY
0"
r = 5C.
BLDG A - BASEMENT
'-
+co
HATCH PATTERN
SD
10
20
CO
100' - 0"
' -0
T
HAL
"
123' - 2"
ASP
2'
-0"
r=3
'-
0' - 0
13
"
6"
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
LANDSCAPE DRAWINGS
TRUNCATED DOME
C.I.P. CONC. RETAINING WALL DETECTABLE 21802.1
WARNING SURFACE
PLOT DATE
0"
r=
6"
0"
'-
'-
20'
20
1/22/2021 1:04:23 PM
33
- 0"
r=
r=
13' - 0"
F C DATE: 01/22/21
SCALE: As indicated
DRAWN: TM
CHCKD: TM
1
A103
PARTIAL SITE PLAN - NORTH
1" = 10'-0"
A A103
t: 425-453-0606
www.wattenbarger.com
A B C D E F
A502
73' - 9"
2
11' - 3" 20' - 6" 29' - 4" 12' - 8"
7 7
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
32' - 0 1/2"
10635
MAINT. Revision Schedule
HTRS.
LAUNDRY 015 2 A503
013
29' - 0"
PASSAGE
011 TELECOM. C
016 EMP. A601
SOILED LOUNGE B
BUILDING PLANS −
008 A601
ARCHITECTURAL
LIN.
012
BASEMENT
OVERALL
5 EMP. 5
BATH
1 / A208
1 / A209
STAIR 1
ST001 009
B
A601
UP 16' - 0"
G H J K L M N
A502
30' - 8 1/2"
22' - 0"
006 ELEC.
2 001
A03 A04 A05 A06 A07 A08 A09 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21
CENTER
A103
ADA VAN ADA STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD COMPACT STANDARD STANDARD STANDARD
3 CHEM. 3
STG.
018
A02
COMPACT
PARKING
68' - 0"
26' - 0"
26' - 0"
FD 000 FD
D 1 A503
A01
A601 COMPACT
2 2
STAIR 3
A37 A36 A35 A34 A33 A32 A31 A30 A29 A28 A27 A26 A25 ST003 A24 A23 A22
20' - 0"
20' - 0"
STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD
UP
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
E
A602
1 1
PLOT DATE
1/22/2021 1:04:29 PM
1 / A209
1 / A208
DATE: 01/22/21
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4"
SCALE: 3/32" = 1’−0"
273' - 9"
DRAWN: ALL
CHCKD: TM
1
A201
GROUND FLOOR PLAN OVERALL
3/32" = 1'-0"
A A201
t: 425-453-0606
www.wattenbarger.com
C D E F
A
A601
A502
62' - 0"
20' - 6" 29' - 0" 13' - 0"
2
UNIT UNIT
REGISTERED
STATE OF WASHINGTON
ARCHITECT
MC4−b UNIT MC2 MC2−b
TRAVIS McDANOLD
112 113 114
32' - 0 1/2"
32' - 0 1/2"
10635
UNIT MC4
111
61' - 0 1/2"
Revision Schedule
6 6 # DESCRIPTION DATE
UNIT
MC2−b 2 A503
110
29' - 0"
29' - 0"
C
A601
B
UNIT MC2 THEATER
BUILDING PLANS −
A601
ARCHITECTURAL
109 115
CORRIDOR
1ST FLOOR
OVERALL
5 103 5
1 / A210
1 / A211
DN
STAIR 1
B ST101 G H J K L M N
16' - 0"
A601 G H J K
A602 A602 A603 A603
A B UNIT MC6 A502
30' - 8 1/2"
174' - 6"
108
3
159' - 9"
EL. LBY.
85' - 9" 48' - 0" 45' - 0" 6' - 1"
101 WOMEN
A504 116
A504 1
2
MEN
UNIT MC7 117
4 107 4
22' - 0"
106 SVC MC3−b
SPRINKLER 105 LOUNGE UNIT MC3 UNIT MC3 MC3−b
2 LOBBY 118 RES. 131 132 133 134 POOL ABOVE
RISER 104 LAUNDRY
CENTER
150 A103
130 POOL
NURSE HALL
STATION MED RM 127 EQUIP.
3 121 120 135 3
TRASH
149
UNIT MC5
136
DINING CORRIDOR
68' - 0"
26' - 0"
26' - 0"
125 122
D SERVERY 1 A503
LOADING
A601 148 126
ACTIVITY
123 UNIT MC4
137
DN
2 2
STAIR 3
20' - 0"
20' - 0"
RAMP DOWN UNIT UNIT UNIT UNIT UNIT
MC PATIO MC1−b UNIT MC1 MC1−b UNIT MC1 MC1−b UNIT MC1 MC1−b UNIT MC1 ST103 MC4−b
124 146 145 144 143 142 141 140 139 138
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
E UP
A602
1 1
2 PLOT DATE
1 / A211
1 / A210
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4" DATE: 01/22/21
273' - 9"
H SCALE: 3/32" = 1’−0"
F G J K
A602 A602 A602 A603 A603 DRAWN: Author
CHCKD: Checker
1
A202
FIRST FLOOR PLAN OVERALL
3/32" = 1'-0"
A A202
t: 425-453-0606
www.wattenbarger.com
C D A
E F
A601
62' - 6"
20' - 6" 29' - 0" A502 13' - 0"
UNIT C8 UNIT C7
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
251 252
32' - 0 1/2"
32' - 0 1/2"
10635
Revision Schedule
6 6 # DESCRIPTION DATE
UP A503
UNIT A1 2
STAIR 2
250 ST202
A617
3
29' - 0"
29' - 0"
12' - 3 7/8" 12' - 3 7/8" C
UNIT A1
A601
249 LIVING B
BUILDING PLANS −
ROOM A601
ARCHITECTURAL
203
2ND FLOOR
OVERALL
5 5
1 / A212
1 / A213
B
UNIT A1 G H J K L M N
A601 248 174' - 6"
4
H
A B A502
30' - 8 1/2"
A617
A602
ELEV.
3
159' - 9"
LOBBY
204 VEST.
A504 UNIT A1 201
A504 1 247
2 OUTDOOR CAFE SEATING STRG
218
LOBBY
4 202 4
22' - 0"
CORR. PUB ALCOVE 214
205 207
239 208 UNIT B4 UNIT B4 POOL
CENTER
215 216 217
STOR.
SERVICE
206
3 TRASH JAN. 3
244 MEN 213
FOUNTAIN 211
SHOWER TOILET
CORRIDOR 219
68' - 0"
26' - 0"
UNIT C9 MKTG MAIL 220
26' - 0"
20' - 0"
230 UNIT B11 UNIT B10
UNIT C10 241 240 UNIT A1 UNIT A1 UNIT A1 UNIT A1 225 224
EX. DIR.
242 229 228 227 226
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
1 1
PLOT DATE
1/22/2021 1:04:46 PM
1 / A213
1 / A212
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4"
DATE: 01/22/21
273' - 9"
SCALE: 3/32" = 1’−0"
F DRAWN: Author
G H J K
A602 A603 CHCKD: Checker
A602 A602 A603
A B C D E F G H J K L M N NORTH
BLDG. SHEET NO.:
A A203
1
1 SECOND FLOOR PLAN OVERALL A501
A203 3/32" = 1'-0"
t: 425-453-0606
www.wattenbarger.com
C D E F
A
A601
62' - 6"
20' - 6" 29' - 0" A502 13' - 0"
UNIT C1
REGISTERED
306
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
32' - 0 1/2"
32' - 0 1/2"
10635
UNIT C1
307
61' - 0 1/2"
Revision Schedule
6 6 # DESCRIPTION DATE
UNIT B3
305 2 A503
STAIR 2
ST302 A617
3
29' - 0"
29' - 0"
UNIT B5 C
308 A601
B
BUILDING PLANS −
CORR. A601
ARCHITECTURAL
302
3RD FLOOR
OVERALL
5
1 / A214
1 / A215
3'
-0
B "
A601
UNIT B3
4
304
A B H J K A502
L M N
30' - 8 1/2"
A617
ELEV. LIBRARY
3
309
159' - 9"
174' - 6"
LOBBY
301 3'
-0
A504 "
A504 1 UNIT B3
2
303
OPEN BELOW
4 4
22' - 0"
UNIT B2 UNIT B2 322
SVC./HKPG. 318 319
338 SPORTS
CENTER
THEATER DEN
311 312
3 3
UNIT C2
337
CORR. CORR.
313 314 UNIT B7
68' - 0"
324
26' - 0"
26' - 0"
D STAIR 3 1 A503
A601 ST303
UNIT B8
325
2 2
UNIT B2 UNIT B2 UNIT B2 UNIT B2
334 333 330 329
UNIT C3 UNIT B1 UNIT B1 UNIT B1b
20' - 0"
20' - 0"
336 335 328 327 UNIT B9
UNIT B1 UNIT B1
326
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
E 332 331
A602
1 1
PLOT DATE
1/22/2021 1:04:54 PM
1 / A215
1 / A214
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4"
DATE: 01/22/21
F G
2 273' - 9" H J K SCALE: 3/32" = 1’−0"
A602 A602
G004 A602 A603 A603 DRAWN: Author
CHCKD: Checker
A B C D E F G H J K L M N
BLDG. SHEET NO.:
NORTH
A A204
1
1 THIRD FLOOR PLAN OVERALL A501
A204 3/32" = 1'-0"
t: 425-453-0606
www.wattenbarger.com
C D E F
A
A601
62' - 6"
A502
20' - 6" 29' - 0" 13' - 0"
2
UNIT C1
REGISTERED
STATE OF WASHINGTON
ARCHITECT
406
TRAVIS McDANOLD
32' - 0 1/2"
32' - 0 1/2"
10635
UNIT C1
407
61' - 0 1/2"
Revision Schedule
6 6 # DESCRIPTION DATE
2 A503
CORR.
STAIR 2
402
ST402 A617
3
UNIT B3
29' - 0"
29' - 0"
405
C
A601
B
UNIT B5
BUILDING PLANS −
A601
ARCHITECTURAL
408
4TH FLOOR
OVERALL
5 5
1 / A216
1 / A217
B
A601 UNIT B3
404 4
A B H J K A502
L M N
30' - 8 1/2"
A617
174' - 6" 3
159' - 9"
ELEV.
A504 UNIT B3 LOBBY
A504 1 403 401
2
4 4
22' - 0"
PED. -
UNIT B2 UNIT B2 UNIT B2
SVC./HKPG. POSSIBLE 418 419 422
438 PLUMBING SALON
CENTER
412
3 STYLING
3
UNIT C2
437
68' - 0"
26' - 0"
26' - 0"
D 1 A503
A601
UNIT B8
2 UNIT B2 UNIT B2
425 2
430 429
UNIT B2 UNIT B2
434 433 UNIT B9
426
20' - 0"
20' - 0"
UNIT B1 UNIT B1 UNIT B1 UNIT B1b
UNIT C3 UNIT B1 432 431 428 427
436 435
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
E
A602
1 1
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4"
273' - 9" DATE: 01/22/21
SCALE: 3/32" = 1’−0"
F G
2 H J K
DRAWN: Author
A602 A602
G004 A602 A603 A603
CHCKD: Checker
A A205
1
1 FOURTH FLOOR PLAN OVERALL A501
A205 3/32" = 1'-0"
t: 425-453-0606
www.wattenbarger.com
C D E F
A
A601
UNIT C1
REGISTERED
STATE OF WASHINGTON
ARCHITECT
506
TRAVIS McDANOLD
32' - 0 1/2"
32' - 0 1/2"
10635
UNIT C1
507
Revision Schedule
6 6 # DESCRIPTION DATE
UNIT B3
505 CORR. STAIR2 2 A503
502 ST502
DN
91' - 9"
29' - 0"
29' - 0"
C
UNIT A3 A601
B
508
BUILDING PLANS −
A601
ARCHITECTURAL
5TH FLOOR
OVERALL
5 5
1 / A218
1 / A219
B MEN G H J K L M N
A601 503 G H J K
ROOFTOP A602 A602 A603 A603
A B MECH. EQP. A502
30' - 8 1/2"
30' - 8 1/2"
174' - 6"
R6 3
159' - 9"
ELEV.
A504 LOBBY
A504 1 PASSAGE 501
531
2
KIT. OFF.
532
4 4
22' - 0"
509 UNIT B2 UNIT B2 UNIT B2
518 519 522
COOKLINE TRASH JAN.
CENTER
536 534
CORR. WOMEN
KITCHEN 513a 510
3 538 MECH. 3
535
68' - 0"
26' - 0"
26' - 0"
D DN 1 A503
A601
STAIR 3
ST503
MAIN
DINING
WINE WALL
511 PUB
2 512 BAR UNIT C4 UNIT C4 UNIT C11
2
528 527 UNIT C5
UNIT A2 526 525
529
STOR.
20' - 0"
20' - 0"
512A
ROOF DECK
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
E
R13 R11 R11
A602
R11 R11
R12 R12 R11 R12 R11 R12 R11
1 R12
1
K
PLOT DATE
A603
1/22/2021 1:05:10 PM
1 / A219
1 / A218
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4" DATE: 01/22/21
273' - 9" SCALE: 3/32" = 1’−0"
DRAWN: Author
F
A602 CHCKD: Checker
G H J
A602 A602 A603
BLDG. SHEET NO.:
A B C D E F G H J K L M N NORTH
1
A206
FIFTH FLOOR PLAN OVERALL
3/32" = 1'-0"
A A206
t: 425-453-0606
www.wattenbarger.com
TOTAL NFA Mult NFA (Sq. In.) GROSS ATTIC REQUIRED
VENT TYPE L.F. (Sq. In./LF) PROVIDED Low, High % ZONE AREA VENTING
Zone A 3,340 SF 1,603 in²
ZONE A - HIGH Zone B 1,062 SF 510 in²
RIDGE VENT 121' 12 1,454 51% Zone C 1,508 SF 724 in²
121' 1,454 51% Zone D 10,513 SF 5,046 in²
ZONE A - LOW
EAVE - STRIP VENT 178' 8 1,425 49%
178' 1,425 49%
C D E F 299' 2,878 100%
BELLEVUE, WA 98004
ZONE B - LOW LOW: 1,425 (49%) LOW: 419 (49%)
EAVE - STRIP VENT 33' 8 263 43% TOTAL: 2,897 SQ IN TOTAL: 861 SQ IN
33' 263 43%
61' 605 100% ZONE B: ZONE D:
ZONE C - HIGH HIGH: 342 (57%) HIGH: 3,032 (60%)
EAVE - STRIP VENT 21' 8 168 20% LOW: 263 (43%) LOW: 2,025 (40%)
RIDGE VENT 23' 12 273 32% TOTAL: 605 SQ IN TOTAL: 5,056 SQ IN
7 16'
7 Venting Zones Legend ZONE C - LOW
44' 441 51%
REGISTERED
STATE OF WASHINGTON
52' 419 49%
ARCHITECT
5" / 12"
Zone A
TRAVIS McDANOLD
5" / 12" 96' 861 100% 1. VENTING REQUIREMENT CALCULATED AT 1/300
5" / 12"
5" / 12" R4 RATIO PER IBC 1203.2 & NCRA ROOFING AND
14'
17'
ZONE D - HIGH
20'
R4 DAMPPROOFING MANUAL 5TH E.D.
EAVE - STRIP VENT 27' 8 216 4%
3" / 12"
R4 Zone A
R4
R4 Zone B RIDGE VENT 235' 12 2,816 56% 2. NO DRAFTSTOPPING REQUIRED PER IBC
262' 3,032 60% 718.4.3 EXCEPTION 1
3,340 SF
10635
ZONE D - LOW
32'
Zone C EAVE - STRIP VENT 253' 8 2,025 40%
253' 2,025 40%
52'
3" / 12"
R4 3" / 12" TOTAL PROVIDED: 972' 9,401
3" / 12" Revision Schedule
14'
15'
22' # DESCRIPTION DATE
R4
19'
6 6
R4 3" / 12"
1/4" / 12"
5" / 12" R5
R4
5" / 12" R8
11'
3" / 12" C
R4
15'
14'
ARCHITECTURAL
3" / 12" A601
B
R4
ROOF PLAN
23'
R4 A601
OVERALL
5 5
1 / A220
1 / A221
1/4" / 12"
3" / 12"
14'
B
1/4" / 12"
1/4" / 12"
A601 R4
1/4" / 12" R6 R10
33'
A B Zone B G H J K J L M K N
1,062 SF H A603 A603
1/4" / 12" R7 A602
1/4" / 12" 1/4" / 12"
5" / 12"
R10 5" / 12" 5" / 12"
+co
SD
3'
R4 R4
3" / 12"
5" / 12" R4
1/2" / 12"
23'
5" / 12" 5" / 12" 5" / 12" 5" / 12" 5" / 12" 12'
R4 R4
3" / 12"
R4
25'
1/4" / 12"
R4
3" / 12"
R4 R4 R4 R4 R4 22' R4
3" / 12"
R7 R4 17'
3" / 12"
R4
CENTER
R8 R4
3" / 12"
18' 17' 17' R4
1/4" / 12" 1/4" / 12"
26'
1/4" / 12" 40'
1/4" / 12"
8' R4 27'
R6
3 1/4" / 12" R10 3
1/4" / 12"
2-HR FIRE BARRIER
R6 R7 R7 Zone C
3" / 12"
R4
1/4" / 12" 1,508 SF Zone D 5" / 12"
1/4" / 12"
R10 1/4" / 12" 10,513 SF 1/4" / 12" R6
1/4" / 12"
R6 1/4" / 12" R6 R4
R6 R6
25'
1/4" / 12"
D 1/4" / 12"
1/4" / 12"
A601 13'
1/4" / 12" 5" / 12"
5" / 12"
R8 R7 R4
R4
2 2
3" / 12"
1/4" / 12"
R4
3" / 12"
R7 R4 R4 R4 R4
24'
5" / 12"
R4 R4 R4
5" / 12" 5" / 12" 5" / 12" 5" / 12"
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
1 1
4' - 0" 4' - 0"
PLOT DATE
1/22/2021 1:05:15 PM
F
H
J DATE: 01/22/21
1 / A221
1 / A220
A602 K
G A602
A603 SCALE: 3/32" = 1’−0"
A603
A602
A B C D E F G H J K L M N DRAWN: ALL
CHCKD: TM
1
A207
ROOF PLAN
3/32" = 1'-0"
A A207
t: 425-453-0606
www.wattenbarger.com
1 2 3 4 5 6
FLOOR PLAN GENERAL NOTES:
BELLEVUE, WA 98004
A951 OTHERWISE.
2 13 W1-8 W17
5' - 0"
W1-12 W2-12 UP W2-10 A611
A103 4. DOORS AND CASED OPENINGS
W08 INDICATED ADJACENT TO WALL
W08
C C INTERSECTIONS SHALL BE
LOCATED WITH THE EDGE OF
013b FINISHED OPENING SIX INCHES
UP FROM THE ADJACENT WALL AT
W1-12 009A
7 THE EXTERIOR AND FOUR INCHES
W17 FROM THE ADJACENT WALL AT
WA-3 DR-3
ST001 W15 INTERIOR LOCATIONS.
W17 8 A712 1
W14
20' - 6"
5. SEE SHEETS A222 - A225 FOR
REGISTERED
STATE OF WASHINGTON
ARCHITECT
STAIR 1 012b W15 CONCRETE DIMENSIONAL
TRAVIS McDANOLD
ST001 9 2 A712 5
W14 VESTIBULE CONTROL PLANS.
W1-8 010 SOILED W14
LAUNDRY
W14 6. SEE ENLARGED PLANS WHERE
W1-8
LIN. 013 4
REFERENCED FOR ADDITIONAL
STORAGE 012 DIMENSIONS AND CALLOUTS.
17.9%
013
007
10635
009B
7. SEE A400 SHEETS FOR REFLECTED
W15 012
D D CEILING PLANS.
F W14
W14 W14 W17
A602 PASSAGE
50' - 0"
W14 011 W1-8 Revision Schedule
W17 W14 014
FEC-1 MAINT.
011 # DESCRIPTION DATE
014
007 016
W14
13 W14 A
006
10.0%
W1-12 A609 SVC. W14 9 TELECOM.
11' - 6 1/4"
14 A601
15 A610 016 015
29' - 0"
A950
LOBBY W14 9' - 10 1/4" 11' - 4 3/8"
A950
006 W13
W14
EMP.
000
BATH WTR.
W1-10 W2-12 HTRS.
009
BASEMENT PARTIAL
ELEC. LOBBY
005 015
W11 001 3
W11
A01 A02 A712
PLAN − N
COMPACT COMPACT 009
001A 001B
E FEC-1 6
E
008
ELEV. 2
EQP. W14 A307 EMP. 20' - 1 3/4"
002 LOUNGE
13' - 0"
002 W17
12' - 0"
W11 008 W1-12
005
W17
A03
W11
ADA VAN
F PARKING F
ENTRY 28' - 9 1/2"
004
1 W1-12
3 A609
A606 W1-12
20' - 3"
A04
ADA 13' - 5 1/4"
2
5 6
CENTER
G G A503
W1-8 A37
W1-12
STANDARD
A05
STANDARD
G G
A602 A602
33' - 0"
A36
STANDARD C
A06
STANDARD A601
A35
STANDARD
A07
W2-12 STANDARD
H H
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
JOB NO.:
21802.1
PLOT DATE
1/22/2021 1:05:19 PM
DATE: 01/22/21
SCALE: As indicated
1 2 3 4 DRAWN: Author
N CHCKD: Checker
1
A208
BASEMENT - NORTH
1/8" = 1'-0"
A A208
t: 425-453-0606
www.wattenbarger.com
FLOOR PLAN GENERAL NOTES:
BELLEVUE, WA 98004
1 / A208 1 / A208 4. DOORS AND CASED OPENINGS
A34 A08
INDICATED ADJACENT TO WALL
MATCH LINE STANDARD STANDARD MATCH LINE INTERSECTIONS SHALL BE
LOCATED WITH THE EDGE OF
FINISHED OPENING SIX INCHES
FROM THE ADJACENT WALL AT
G008 3 THE EXTERIOR AND FOUR INCHES
FROM THE ADJACENT WALL AT
29' - 0"
A33 A09 INTERIOR LOCATIONS.
STANDARD STANDARD
5. SEE SHEETS A222 - A225 FOR
CONCRETE DIMENSIONAL
REGISTERED
STATE OF WASHINGTON
ARCHITECT
FEC-2 W1-12 CONTROL PLANS.
TRAVIS McDANOLD
H H 6. SEE ENLARGED PLANS WHERE
A32 A10 REFERENCED FOR ADDITIONAL
A602 A602 DIMENSIONS AND CALLOUTS.
STANDARD STANDARD
7. SEE A400 SHEETS FOR REFLECTED
10635
CEILING PLANS.
J J
F01
STANDARD STANDARD
# DESCRIPTION DATE
W1-8
29' - 0"
A30 A12
STANDARD STANDARD W1-12
BASEMENT PARTIAL
A29 A13
8' - 0"
STANDARD STANDARD
W2-12 W2-12
PLAN − S
K K
A28 A14
STANDARD STANDARD
J J
A603 A603
29' - 0"
28' - 0"
A27 A15
W1-8
STANDARD STANDARD
A501 2 3 A502
L L
8' - 0"
CENTER
A25 A17
W1-12
STANDARD STANDARD
24' - 2"
W14
A18
ST003
COMPACT
POOL
9
UP STAIR 3 EQUIP.
A612 ST003 017
CHEM.
FEC-1 STG. 018 017
M 018 M
W14
A24 A19
46' - 0"
STANDARD STANDARD W1-12
K K
30' - 4"
STANDARD STANDARD
A22 A21 4
STANDARD STANDARD
JOB NO.:
N N 21802.1
6' - 1"
6' - 1"
W1-12 PLOT DATE
1/22/2021 1:05:22 PM
1 4 N CHCKD: TM
BELLEVUE, WA 98004
5' - 3"
2 A504 4. DOORS AND CASED OPENINGS
B INDICATED ADJACENT TO WALL
B B A601 INTERSECTIONS SHALL BE
LOCATED WITH THE EDGE OF
F01 2' - 5 7/8" 3' - 9 3/4" FINISHED OPENING SIX INCHES
4' - 4 1/2" 3' - 3" 5' - 9" 3' - 10" 8' - 0 1/2" 7' - 9 1/2" 12' - 6" 4' - 0" 10' - 7 3/4" 4' - 0" 10' - 10 1/8" 3' - 11 3/4"
8 FROM THE ADJACENT WALL AT
11' - 3"
A951 W09 9 THE EXTERIOR AND FOUR INCHES
16' - 8 5/8" FROM THE ADJACENT WALL AT
2 A611
W08 INTERIOR LOCATIONS.
W08a
7 A103
149C
147
A951 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 5. SEE SHEETS A222 - A225 FOR
C C CONCRETE DIMENSIONAL
REGISTERED
STATE OF WASHINGTON
ARCHITECT
CONTROL PLANS.
TRAVIS McDANOLD
SPRINKLER UNIT
UNIT MC2 UNIT MC4 6. SEE ENLARGED PLANS WHERE
W14 RISER W13 6" MC2−b REFERENCED FOR ADDITIONAL
W2-8 W08a 150 21' - 8 3/8" 15' - 7 3/4" 109 111
ANSI TYPE ’B’ 110 ACCESSIBLE
DIMENSIONS AND CALLOUTS.
ANSI TYPE ’B’
UNIT MC7 UNIT MC6 7. SEE A400 SHEETS FOR REFLECTED
10635
W1-12
21' - 0"
20' - 6"
148A
ST101
28' - 6 3/8"
TRASH W13
LOADING 149 W13
Revision Schedule
148 W2-12
W2-12 # DESCRIPTION DATE
W1-8 W05
W18 DN
D UNIT D
F IDF MC4−b
112 J1
106
148B
A602
ST101
W2-12
3' - 3"
ACCESSIBLE
5' - 0"
4' - 11"
W13
106
W14 J1
9
W12
A609 CORRIDOR
9' - 3 1/4"
25' - 8 7/8" W13
104 103 14' - 8 1/2" W13 A
W18
A601
W03 6' - 9 3/8"
PARTIAL PLAN − N
29' - 0"
W13 FEC-1
W08 W2-12 SVC 49' - 7 1/8" UNIT MC2
W13 113 J6
FIRST FLOOR
14' - 9"
17' - 9"
LOBBY
2' - 1 1/2"
4' - 0"
4' - 9"
104
38' - 6"
W19
W15 126B 6 W13 2
W03 W13 A502
J6
105
W18 EL. LBY.
W08 W2-12
SERVERY JAN. 101 A713 THEATER W18
17' - 0"
11' - 9 3/4"
2' - 9"
6"
112
126 105 115 W13
11 A712
3' - 3 5/8"
W03 101
E 10 W14 E
15' - 9 3/8"
W08a UNIT J1
3' - 2 3/4"
W18 MC2−b
114
13' - 0"
6' - 1 7/8"
102 A610 J1
116 W17
40' - 10 3/8" 6" 15' - 11"
21' - 4"
F F
117
3
20' - 3"
MEN
13' - 5 1/4"
A606 W14a
117
CENTER
MC PATIO B
124 A601
1
W18 A307
2
W08a
G G 5 A503 6 7
FEC-1
LOUNGE
118
ACTIVITY
123
W14 9 A713 W1-12
W13 W17
G G
W08a 10
A602 A602
33' - 0"
123
122 C
A601
3' - 3" 5' - 5 1/2"
W08 4
J6
UNIT NURSE
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
A713 5
MC1−b STATION
146 121
J6
ANSI TYPE ’B’ W13
11' - 1 3/8"
DATE: 01/22/21
SCALE: As indicated
DRAWN: Author
N CHCKD: Checker
BELLEVUE, WA 98004
W13
1 / A210
120 1 / A210
4. DOORS AND CASED OPENINGS
13' - 5 3/8"
INDICATED ADJACENT TO WALL
3' - 3"
3' - 3"
MATCH LINE MATCH LINE INTERSECTIONS SHALL BE
UNIT MC1 1 A713 2 CONSULT. LOCATED WITH THE EDGE OF
145 FINISHED OPENING SIX INCHES
119 FROM THE ADJACENT WALL AT
ANSI TYPE ’B’
G008 3 W13 THE EXTERIOR AND FOUR INCHES
3
11' - 4 5/8"
11' - 4 5/8"
F03 FROM THE ADJACENT WALL AT
6"
29' - 0"
INTERIOR LOCATIONS.
REGISTERED
STATE OF WASHINGTON
ARCHITECT
3' - 3"
MC1−b 128 CONTROL PLANS.
TRAVIS McDANOLD
144
14' - 0"
3' - 3"
A712 6. SEE ENLARGED PLANS WHERE
H ANSI TYPE ’B’ H
1' - 5 7/8"
REFERENCED FOR ADDITIONAL
A602 HALL 128 A602 DIMENSIONS AND CALLOUTS.
127 129
127 7. SEE A400 SHEETS FOR REFLECTED
1' - 6"
11' - 1 3/8"
10635
6"
CEILING PLANS.
J J
1' - 6 1/8"
1' - 6" 15
14' - 0"
3' - 3"
3' - 3"
4' - 6"
ANSI TYPE ’B’ 130 # DESCRIPTION DATE
130a 13
J6 W13
11' - 4 1/4"
11' - 4 1/4"
6"
29' - 0"
W13
UNIT CORRIDOR
MC1−b 122 UNIT MC3
13' - 5 3/8"
15' - 6"
142 131
3' - 3"
25' - 6"
ANSI TYPE ’B’ ANSI TYPE ’B’ J4
3' - 3"
PARTIAL PLAN − S
W2-12
W2-12
FIRST FLOOR
J4
11' - 0 5/8"
11' - 1 3/8"
6"
K K
UNIT
J6
0"
13' - 5 3/8"
UNIT MC1 MC3−b
14' - 0"
3' - 3"
J6
141 132
4' - 6"
ANSI TYPE ’B’ ANSI TYPE ’B’
J J6 J
W13 J6
A603 W13 A603
11' - 4 5/8"
W13
7' - 0"
6"
6"
29' - 0"
18' - 0"
J6
A501 2 UNIT MC3 J6 3 A502
4' - 6"
UNIT W13 133
14' - 0"
14' - 0"
MC1−b ANSI TYPE ’B’
3' - 3"
J6
140 J6
0"
W13
11' - 1 3/8"
11' - 0 5/8"
6"
6"
L L
UNIT J4
CENTER
MC3−b
13' - 10 1/4"
J6 UNIT MC1
134
3' - 3"
J4
7' - 4 1/2"
139
15' - 6"
ANSI TYPE ’B’
ANSI TYPE ’B’
W12
24' - 2"
J6 W13
W13
11' - 11 1/8"
ST103A STAIR 3
ST103 ST103B
135 POOL W2-8
5
17' - 3 1/2"
EQUIP.
14' - 10 7/8"
A612 FEC-1 W1-12
135
4' - 10 5/8"
DN
3' - 10 3/4"
M M
W13
10' - 5 5/8"
J6
W2-8
4' - 0"
14' - 0"
UNIT
J6
MC4−b 15' - 0"
28' - 2"
29' - 2"
138
ACCESSIBLE
K K
28' - 2 3/4"
UNIT MC5
30' - 4"
A603 A603
UNIT MC4
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
136
137 W13 ANSI TYPE ’B’ W2-8
20' - 1 1/2"
ACCESSIBLE
W08 6"
28' - 8 3/8" 16' - 2 1/2"
W18
W08
W2-12 PLOT DATE
1/22/2021 1:05:33 PM
4
A903 DATE: 01/22/21
4' - 11 1/4"
23' - 4 1/2" 3' - 7 1/2" 4' - 11 1/4" 3' - 7 1/2" 26' - 7" SCALE: As indicated
20' - 0" 26' - 0" 22' - 0" DRAWN: Author
1 N CHCKD: Checker
5' - 3"
W08 ARE 45° UNLESS NOTED
2 A504
UNIT C9 OTHERWISE.
BELLEVUE, WA 98004
10' - 2"
10' - 6"
B 243 B
6' - 1 3/4" 4. DOORS AND CASED OPENINGS
47' - 4 1/8" ANSI TYPE ’B’ INDICATED ADJACENT TO WALL
0" 17' - 3 1/8" 4' - 0" 7' - 10 1/4" 4' - 0" 12' - 6" 4' - 0" 10' - 7 3/4" 4' - 0" 10' - 9 1/2" 4' - 0" 20' - 6 1/4" INTERSECTIONS SHALL BE
8
G3 LOCATED WITH THE EDGE OF
A951 W13 G3 W04 FINISHED OPENING SIX INCHES
W03 FROM THE ADJACENT WALL AT
6' - 10"
5' - 9" W08
W08 W2-12 THE EXTERIOR AND FOUR INCHES
FROM THE ADJACENT WALL AT
G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 INTERIOR LOCATIONS.
C C
36' - 5 3/8"
4' - 6"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 CONCRETE DIMENSIONAL
G3
TRAVIS McDANOLD
31' - 9"
9' - 10"
W2-12
ANSI TYPE ’B’ ANSI TYPE ’B’ ANSI TYPE ’B’ 1' - 7 1/4" ANSI TYPE ’B’ ANSI TYPE ’B’ 6. SEE ENLARGED PLANS WHERE
6" W13
7' - 3"
28' - 4 7/8" 1' - 7 1/4" 13' - 7 3/8" 13' - 8" 6" 13' - 7 3/8" 13' - 8 3/8" 6" 13' - 9" 28' - 9 3/8" REFERENCED FOR ADDITIONAL
DIMENSIONS AND CALLOUTS.
G3 UNIT C10
10635
242 P 7. SEE A400 SHEETS FOR REFLECTED
W13
W2-12 W18 CEILING PLANS.
4' - 6"
29' - 10"
G3 W13 W13
W13 W08
W13
17' - 4 1/4"
Revision Schedule
W04
6"
9' - 0"
F UNIT C8
7' - 9 3/8"
A602 G3 FEC-1 251
TRASH ANSI TYPE ’B’
G3
7' - 11 7/8"
244
13' - 8"
5 244
UNIT A1
6' - 3"
A613
241 W13 G3
8' - 10 3/4"
G3 ANSI TYPE ’B’
4' - 2" 5' - 8 1/4" 16' - 4 3/4" 11' - 10 3/4" 17' - 6 1/4" 11' - 10 3/4" 8' - 6 5/8" 4' - 10 1/2" A
10' - 3 1/4"
FEC-1 W13 A601
6"
6' - 3"
5 W12 W13
29' - 0"
W08 W13
16' - 3 1/8"
A609 64' - 9" W13a
CORR. G3
PARTIAL PLAN − N
SECOND FLOOR
239 UNIT C7
14' - 1"
W13 204 7' - 9 3/8"
G3 252
12' - 7 3/8" W13
STAIR 2
IDF/ELEC. W13 ST202 ANSI TYPE ’B’
8' - 6"
13' - 8"
UNIT A1 W13
245 G3
2 A502
240 W13 3
7' - 6"
17' - 5 1/8"
ANSI TYPE ’B’ 15' - 6" 245 6" 6' - 7 5/8" A611 W13
16' - 9"
J3 W08
A714 1
6"
STOR. W04
8' - 7"
8' - 1"
LIVING
E W13
206
ROOM
W18
E
237B W14 RECEPTION 203
16' - 5 1/8"
6"
A1 EX. DIR. 205 D
MKTG 5
11' - 5"
6"
239
236 W14 CONF. 238 A610
13' - 0"
W12
1' - 4 1/8"
237 6' - 11" 8' - 9 1/4" 6" 31' - 5 7/8"
8' - 3 1/4"
FEC-1
A1 W14 ST202A W18
W18
6"
W14
236 237 238 W04b
16' - 3"
202 J9 J9 E
19' - 10" M2 M2
W2-12
A1 234 233
4' - 0" 6' - 9 1/2" 3' - 8" 3' - 8" 7' - 3 1/2" 8' - 5 1/4" 32' - 2 3/8"
3 H.R. W14 FOUNTAIN VEST.
SUPPLY
10' - 2"
BUS. A307
6"
MGR. W15
233
CENTER
W14 W15
ACT. DIR. B
8' - 8"
STOR. W18
17' - 3"
W14
J3 231 232
A601
230A 1 2
231
232
A616
G W18 W04b
G 5 A503 6 7
21' - 6 3/8"
W14
6' - 5 1/4"
W18
J11
W14 5
4' - 6"
A307
J11 207a
MAIL
209 FEC-1
4' - 6"
A714 4 BISTRO /
G J11 ACTIVITY W14 PUB G
16' - 5 1/8"
31' - 8 3/8"
A602
ROOM 207 A602
33' - 0"
A714
230 W04b
4
9' - 11"
5 W08 C
A617 A601
WOMEN
210 3
J8 W18
4' - 0"
207b
210
A617
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
1
1' - 7 1/4"
J8 W18 A308
14' - 3 1/4"
2
230B 208
211 A308 W04b
FIREPLACE
H W13 ALCOVE H
14' - 8"
DATE: 01/22/21
SCALE: As indicated
DRAWN: Author
N CHCKD: Checker
1
A212
SECOND FLOOR - NORTH
1/8" = 1'-0"
A A212
t: 425-453-0606
www.wattenbarger.com
1 2 3 4 FLOOR PLAN GENERAL NOTES:
2' - 6 1/2"
FRAMING, FACE OF CONCRETE,
WOMEN CENTERLINE OF COLUMNS OR
J8 210 207b CENTERLINE OF ROUGH
OPENINGS UNLESS NOTED
OTHERWISE.
4' - 0"
2' - 8 1/2"
1' - 7 1/4"
J8
W18 W2-12 2. DO NOT SCALE DRAWINGS.
5' - 4"
230B
FIREPLACE CONTACT ARCHITECT FOR
211 ALCOVE CLARIFICATIONS.
5' - 5 1/4"
W18
BELLEVUE, WA 98004
211 B3
9' - 6 79/128"
6"
6"
1 / A212 W18 1 / A212
UNIT A1
13' - 9 3/8"
212 2 4. DOORS AND CASED OPENINGS
MATCH LINE 229 MATCH LINE INDICATED ADJACENT TO WALL
INTERSECTIONS SHALL BE
ANSI TYPE ’B’
LOCATED WITH THE EDGE OF
JAN. FINISHED OPENING SIX INCHES
213 213 W04b
4' - 11 49/128"
FROM THE ADJACENT WALL AT
11' - 10 3/4"
THE EXTERIOR AND FOUR INCHES
29' - 0"
29' - 0"
6"
W03 FROM THE ADJACENT WALL AT
W13 INTERIOR LOCATIONS.
W13 A2
5. SEE SHEETS A222 - A225 FOR
REGISTERED
STATE OF WASHINGTON
ARCHITECT
CONCRETE DIMENSIONAL
TRAVIS McDANOLD
W13a CONTROL PLANS.
UNIT A1 A2
13' - 8"
9' - 9"
H W08 228 H 6. SEE ENLARGED PLANS WHERE
24' - 7 1/8"
A602 ANSI TYPE ’B’ W13 A602 REFERENCED FOR ADDITIONAL
DIMENSIONS AND CALLOUTS.
44' - 0 3/4"
A2
16' - 5 1/4"
10635
7. SEE A400 SHEETS FOR REFLECTED
6"
W19
38' - 8 3/8"
W03
4' - 9"
J J CEILING PLANS.
W04b
2' - 7 1/2"
W13
W08
G3
UNIT A1 Revision Schedule
13' - 8"
227 FEC-1
# DESCRIPTION DATE
4' - 6"
ANSI TYPE ’B’ A2
G3
2' - 7 1/2"
8' - 2 7/8"
UNIT C6
11' - 10 3/4"
6"
214
29' - 0"
29' - 0"
A2
4' - 9"
ACCESSIBLE
W13
13' - 9 3/8"
UNIT A1 CORRIDOR
9' - 9"
226 212
6"
4' - 2"
ANSI TYPE ’B’
W13 P
PARTIAL PLAN − S
1' - 7 1/4"
SECOND FLOOR
13' - 8 1/2"
W2-12
W13
2' - 2 1/8"
W04 W2-12
10' - 11 1/4"
4' - 9"
UNIT B4
K K
26' - 9"
215
UNIT B11
5' - 0 5/8"
G3 W13
225
4' - 0"
A1
ANSI TYPE ’B’
W13
J G3 J
23' - 8 3/8"
25' - 0 1/2"
A603 W13 A603
A1
7' - 9 3/4"
W08
7' - 0"
29' - 0"
46' - 0"
29' - 0"
W08
6"
18' - 9 1/8"
G3 A1
3 A502
4' - 0"
G3
W13
6"
A1
10' - 11"
26' - 9"
UNIT B4
4' - 9"
L 216 L
5' - 0 7/8"
ACCESSIBLE
1' - 7 5/8"
2' - 4"
W13 P
CENTER
G3
22' - 11 3/4"
4' - 2"
W08
7' - 4 1/2"
8' - 1 3/4"
W13
6' - 3 3/4"
DF-1
24' - 2"
24' - 2"
5' - 3"
G3
UNIT B10 STRG
9' - 4"
4' - 11 1/4" 4' - 9 1/4" 218
218
224
6"
ANSI TYPE ’B’ 12' - 2" 8' - 3 3/8" 5' - 6" W08
6' - 0"
1
G3 14 A714 W14
217 C
2 A715 4
W18
6' - 2"
STAIR 3 FEC-1
ST203 W13 3
11' - 5 1/4"
13' - 0"
4' - 9"
M W03
M
223
2' - 10"
6"
J8 3' - 2 1/4" 11' - 3"
1
46' - 0"
A612 C
POOL
4' - 0"
219
2' - 8 1/4" 4' - 9" 2' - 5 3/4"
J8 MECH. 217
7' - 6"
222
222 SHOWER
24' - 0"
K
28' - 6 3/8" 219 K
EXERCISE
30' - 4"
30' - 4"
A603 14' - 0" C A603
223 3
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
A308
W18
7' - 6"
221 EQP.
J8
221 TOILET
220
220
25' - 11 3/8" C
4' - 0"
2' - 7 1/2"
J8 28' - 8 3/8" 4
8' - 8"
JOB NO.:
N J8 J8 J8 J8 J3 J8 J3 J8
C C
N 21802.1
5' - 3"
W20
BELLEVUE, WA 98004
2 A504 4. DOORS AND CASED OPENINGS
W20
10' - 2"
INDICATED ADJACENT TO WALL
B B
2' - 9 1/2"
INTERSECTIONS SHALL BE
48' - 5 1/2" 51' - 0 1/2" LOCATED WITH THE EDGE OF
24' - 9 1/2" 5 1/2" 23' - 10" FINISHED OPENING SIX INCHES
F2 8' - 6 1/2" 4' - 2 1/2" 4' - 0" 10' - 6 3/4" 11' - 8 1/4" 9' - 9 1/2" 4' - 0" 4' - 2 1/2" 5' - 9" 10' - 0 1/2" 4' - 0" 10' - 0" 9' - 0 1/2" 12' - 2 1/2"
FROM THE ADJACENT WALL AT
11' - 3"
F2
6' - 10"
W26 THE EXTERIOR AND FOUR INCHES
9' - 2 5/8"
REGISTERED
STATE OF WASHINGTON
36' - 1"
UNIT B3
ARCHITECT
CONTROL PLANS.
304
TRAVIS McDANOLD
K2 303
ANSI TYPE ’B’ W26 6. SEE ENLARGED PLANS WHERE
5 1/2" ANSI TYPE ’B’
5 1/2" 5 1/2" 5 1/2" W20 REFERENCED FOR ADDITIONAL
23' - 6 1/2" 23' - 6 1/2" 23' - 6 1/2" 26' - 7"
13' - 9 1/2"
12' - 1 1/2"
19' - 9 1/2"
W26 7. SEE A400 SHEETS FOR REFLECTED
20' - 6"
UNIT C3
10635
UNIT B3 CEILING PLANS.
336 305
ACCESSIBLE
ANSI TYPE ’B’
34' - 0 1/2"
55' - 3"
6' - 0"
W26 Revision Schedule
5 1/2"
W26
W26a W26
11' - 6"
# DESCRIPTION DATE
W26
D D
2' - 4"
13
F W25
SVC./HKPG. W26a A980 W25 W26a J2
1' - 10 1/2"
338
A602
338 W26 UNIT C1
5' - 3"
P 1 306
3' - 0 3/4"
A613 9' - 8 1/4" ANSI TYPE ’B’
W25 W16
UNIT B1 W25
W26
23' - 2 1/2" 5' - 0 5/8" 6' - 10 7/8" P
335 5' - 5 1/8" 4' - 5 5/8" 5' - 7 1/2"
5' - 3"
13' - 10 1/2"
23' - 9 1/2"
5' - 1 1/2"
29' - 0"
W20 J2
3' - 3 1/4"
5 1/2"
PARTIAL PLAN − N
46' - 4"
W26 W26 10' - 4"
7' - 9 1/4"
7' - 0 3/4"
6' - 6 3/4"
THIRD FLOOR
302 W26a W26
W26
24' - 2 5/8"
M2
42' - 2 1/2"
9 15
W26 8' - 2"
5' - 9"
W20 2 A502
ST302 M2
W26 14 A715 W30 16 A714 13
W30 A609
10' - 10 3/4"
STAIR 2
2' - 6"
F1 310 ELEV.
26' - 7"
W26
311
E LOBBY E
310 301
3' - 7 1/2"
17' - 3 1/2"
3' - 6"
W27
UNIT B2 W27 6 UNIT C1 B1
A610 W26 UNIT B5 307
5' - 5 1/2"
F2 334 311
308
13' - 0"
10' - 8 1/2"
ANSI TYPE ’B’ 11 W27
A920 ACCESSIBLE 5 1/2" 5 1/2"
W26 30' - 0 1/2" 8' - 2" 34' - 0 1/2"
23' - 0" 4' - 6"
F2 CORR.
W20 313
6' - 9 1/2"
8' - 1 1/4"
6' - 0 1/4" K1
F 313
OPEN TO BELOW F
6' - 9 1/2"
7' W20
8' - 2"
4' - 6"
17' - 8 1/2"
3 - 9 W20 W20
UNIT B2 W27 1/
A606 F2 4" 6
2' - 6" 3' - 6" 3' - 7"
333 W27
20' - 3"
W27 5' - 7" 4' - 0" 5' - 7" A611 5' - 7" 4' - 0" 5' - 7" 5' - 2 1/4" 9' - 10 3/4" 4' - 8 1/2"
ANSI TYPE ’B’ W26
CENTER
6 A715 15' - 2" 8' - 2" 15' - 2" 19' - 9 1/2"
SPORTS LIBRARY
1 309
6' - 0"
A601
W20 2
W26 J7 W20
5 6 7
24' - 2 1/2"
5' - 9"
7' - 5 1/2"
7'
G W26 4' - 2 3/4"
-9 J2 G A503
8' - 9"
W26 W26 1/
4 "
M2 W20 W26
M1
23' - 9 1/2"
W20 W26
13' - 11"
UNIT B1 9 UNIT B1
3' - 2 3/8" 5' - 0 5/8"
G A950 316 G
5' - 0 5/8"
4 332
A602 TYP. ANSI TYPE ’B’ A602
33' - 0"
W24 W24 C
5 1/2"
6' - 10 1/4"
A617 A601
9' - 7 1/2"
49' - 0"
9' - 8"
48' - 6"
314
5 1/2"
3
3' - 2 3/8"
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
5' - 0 5/8"
P P A617
5' - 0 5/8"
UNIT B1 UNIT B1
16' - 10"
H H
3
5 1/2"
W26
W26
5' - 9"
5 1/2"
W20
BELLEVUE, WA 98004
A980 A608
4. DOORS AND CASED OPENINGS
1 / A214 1 / A214
INDICATED ADJACENT TO WALL
MATCH LINE MATCH LINE INTERSECTIONS SHALL BE
24' - 2"
24' - 2"
M2
6' - 2 1/2"
M2 W26 LOCATED WITH THE EDGE OF
6' - 6"
5' - 9"
W20 W26 W26 W26 W20 FINISHED OPENING SIX INCHES
FROM THE ADJACENT WALL AT
G008 3 THE EXTERIOR AND FOUR INCHES
2' - 8 1/4"
W26
FROM THE ADJACENT WALL AT
29' - 0"
2' - 6"
INTERIOR LOCATIONS.
3' - 6"
6' - 0"
6' - 0"
F1 G1
W26 5. SEE SHEETS A222 - A225 FOR
24' - 3"
CONCRETE DIMENSIONAL
3' - 3 3/4"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
3' - 7 1/4"
CONTROL PLANS.
UNIT B2
17' - 3 1/2"
TRAVIS McDANOLD
5' - 10 1/4"
UNIT B2 318 6. SEE ENLARGED PLANS WHERE
5' - 0 5/8"
5' - 0 5/8"
H 330 H
4' - 6"
F2 ANSI TYPE ’B’ REFERENCED FOR ADDITIONAL
A602 ANSI TYPE ’B’ A602 DIMENSIONS AND CALLOUTS.
10635
CEILING PLANS.
11' - 3 1/2"
J J
6' - 9 1/2"
8' - 6 3/4"
8' - 6 3/4"
23' - 0"
23' - 0"
5 1/2"
W20
W20
5 1/2"
4' - 6"
F2 Revision Schedule
5' - 0 5/8"
5' - 0 5/8"
N # DESCRIPTION DATE
5' - 10 1/4"
UNIT B2
17' - 3"
UNIT B2
3' - 7 1/4"
F2
W20 329 319
ANSI TYPE ’B’
3' - 6"
ANSI TYPE ’B’
24' - 3"
29' - 0"
6' - 0"
W20 G1
6' - 2 1/2"
24' - 2 1/2"
24' - 2 1/2"
FEC-1
5 1/2"
W26 W26 W26
PARTIAL PLAN − S
M2 W20 W26 W20 M2
THIRD FLOOR
W26
5 1/2"
K K
13' - 5 1/2"
13' - 5 1/2"
W20
UNIT B1
16' - 10"
16' - 10"
328 UNIT B1
320
5' - 0 5/8"
5' - 0 5/8"
ANSI TYPE ’B’
P ANSI TYPE ’B’ P
J J
5 1/2"
A603 W26 W26 A603
6' - 10 1/4"
6' - 10 1/4"
W20
29' - 0"
49' - 0"
49' - 0"
9' - 8"
5 1/2"
9' - 8"
A501 2 P UNIT B1b 3 A502
5' - 0 5/8"
5' - 0 5/8"
327 UNIT B1
P
ANSI TYPE ’B’ 321
16' - 10"
16' - 10"
ANSI TYPE ’B’
13' - 5 1/2"
5 1/2"
L W26 10 L
A612
M2
24' - 2 5/8"
CENTER
W26 W26 M2
6' - 2 1/2"
6' - 2 1/2"
6' - 6"
W20 STAIR 3 W26
ST303
5' - 8"
6' - 0"
18' - 6 3/4"
W26 G1
W20
24' - 3"
11' - 2"
M2
17' - 3 1/2"
UNIT B2 W20
5' - 6"
5' - 7"
322
11' - 3 1/2"
5' - 0"
W20 ANSI TYPE ’B’
24' - 9 1/2"
ST303 N
5' - 8 1/2"
M M
5 1/2"
FEC-1
UNIT B9
326
3' - 5 1/2"
11' - 7 1/4"
ANSI TYPE ’B’
N
W26 J2
W26 W26 W20
W26
W20 W26
5 1/2"
4' - 11 3/4"
16' - 1"
P
UNIT B6
5' - 2 3/4"
5' - 0 1/4"
33' - 4"
K K
323
30' - 4"
J2
32' - 3 1/2"
33' - 2 1/2"
UNIT B7
18' - 9 1/2"
8' - 7 3/4"
W20
G2 324
12' - 1 1/2"
ANSI TYPE ’B’
UNIT B8 W26
5 1/2"
W26
325
10' - 3"
10' - 6"
N N 21802.1
7' - 7 1/2"
N N J7 P J2
W26
W20 PLOT DATE
W20
1/22/2021 1:06:00 PM
N N
W20 DATE: 01/22/21
8' - 0" 15' - 0" 8' - 6" 5' - 6" 10' - 3" 2' - 3" 6' - 6" 12' - 0" 6' - 6"
SCALE: As indicated
49' - 6" 25' - 0"
DRAWN: Author
20' - 0" 26' - 0" 22' - 0"
1 4 N CHCKD: Checker
5' - 3"
ARE 45° UNLESS NOTED
2 A504 A601 OTHERWISE.
W20
BELLEVUE, WA 98004
B B
10' - 2"
4' - 2 1/4" 4. DOORS AND CASED OPENINGS
11' - 3"
F2
437 FINISHED OPENING SIX INCHES
F1 FROM THE ADJACENT WALL AT
ANSI TYPE ’B’
6' - 10"
THE EXTERIOR AND FOUR INCHES
F2 F2 N N F2 F2
36' - 1"
FROM THE ADJACENT WALL AT
F1 M2 F2 F2 M2 B1 INTERIOR LOCATIONS.
C C
3' - 0"
5. SEE SHEETS A222 - A225 FOR
4' - 8 1/2"
K2 W26
5 1/2" CONCRETE DIMENSIONAL
REGISTERED
STATE OF WASHINGTON
ARCHITECT
24' - 9 1/2" 32' - 10" 23' - 6 1/2" 5 1/2" 23' - 6 1/2" 5 1/2" 23' - 6 1/2" 5 1/2" 26' - 7" CONTROL PLANS.
TRAVIS McDANOLD
B1 6. SEE ENLARGED PLANS WHERE
10' - 7 1/2"
7' - 7"
W26
19' - 9 1/2"
W26 W26 DIMENSIONS AND CALLOUTS.
20' - 6"
10635
CEILING PLANS.
P ACCESSIBLE 6' - 8"
3' - 0"
4' - 6"
M2
W26 2
34' - 0 1/2"
55' - 3"
W26
11' - 6"
Revision Schedule
1 A716
5 1/2"
D D
2' - 4"
# DESCRIPTION DATE
F W25 J2
438
A602 10 SVC./HKPG. W25 W26a
UNIT C1
UNIT B1
5' - 3"
A609 438 W26
435 406
P W25
ANSI TYPE ’B’ P
ANSI TYPE ’B’
16' - 10"
W27 5' - 0 5/8" 4' - 5 5/8"
15' - 3 3/4" W26 23' - 2" 5' - 1 1/8" 6' - 10 7/8"
12' - 4 1/2"
11' - 11 3/4"
5' - 3"
1 CORR.
5' - 1 1/2"
439 IDF/ELEC W26 A
A610 402
5 1/2"
W26
42' - 9 1/2"
439 15' - 0 3/8" 5' - 0 1/4"3' - 10 5/8" A601
5' - 11" J2
29' - 0"
W27
3' - 3 1/4"
7' - 9 1/4"
W26 10
7' - 0 3/4"
22' - 6 1/4" A611
6' - 6 3/4"
5 1/2"
PARTIAL PLAN − N
FOURTH FLOOR
402
4' - 3" 3' - 0"
M2 W26
42' - 2 1/2"
W26 M2
8' - 2"
W20 W26 W27 10 A715 2 A502
ST402
12 A715 11
10' - 10 3/4"
STAIR 2
3' - 6" 2' - 6"
G1 SALON ST402
W26 W27
412
26' - 7"
24' - 3"
E 7' - 2 31/128" E
7' - 2 3/4"
4' - 6" 3' - 7 1/2"
10' - 8 1/2"
401 5 1/2" 5 1/2"
ANSI TYPE ’B’ 3' - 11 1/2" 23' - 11" 5 1/2"
6' - 6" 30' - 0 1/2" 8' - 2" 34' - 0 1/2"
5 1/2"
W26 413
G2 5 1/2" 4' - 1"
6' - 9 1/2"
5 1/2"
F W20
F
G2 J5 J5 J5 K1 M2
3' - 1 3/4"
G2 G2 W20 B1
CORR. W26 5' - 0" 5' - 0" 13' - 10 1/2" A1 A1
4' - 6"
4' - 6"
UNIT B2 2' - 6" 4' - 6" 5' - 7" 4' - 0" 5' - 7" 5' - 7" 4' - 0" 5' - 7" 9' - 10 3/4" 4' - 8 1/2"
3 433 UNIT B2 1/4" / 12"
17' - 3 1/2"
15' - 2" 8' - 2" 15' - 2" 19' - 9 1/2"
A606
ANSI TYPE ’B’ 415
G2
3' - 7"
F2
20' - 3"
1/4" / 12"
24' - 3"
5
2' - 6" 3' - 6"
B
W20
CENTER
A601
5 1/2"
G1 W26 F1 2
A616
2
3' - 0" 4' - 3"
6 7
7' - 11 1/2"
G W26 W26 G A503
W26 W26 W20 22.5"
M2
5 1/2"
UNIT B1
2' - 6"
432 W26 M1
23' - 9 1/2"
9' - 2 1/2"
16' - 10"
G 9
UNIT B1 G
A602 A950 TYP. 416 A602
33' - 0"
A617
9' - 7 1/2"
9' - 8"
5 1/2"
5 1/2"
3
P
A617
N
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
UNIT B1 UNIT B1
11' - 11 1/2"
16' - 10"
431 417
ANSI TYPE ’B’ ANSI TYPE ’B’
13' - 11"
H H
3 W20
W26
A608
MATCH LINE MATCH LINE
1 / A217 1 / A217
3' - 0"
M2 JOB NO.:
W26
21802.1
G008 3
PLOT DATE
1/22/2021 1:06:08 PM
DATE: 01/22/21
SCALE: As indicated
DRAWN: Author
N CHCKD: Checker
1
A216
4TH FLOOR - NORTH
1/8" = 1'-0"
A A216
t: 425-453-0606
www.wattenbarger.com
FLOOR PLAN GENERAL NOTES:
1 2 3 4 1. ALL DIMENSIONS ARE TO FACE OF
FRAMING, FACE OF CONCRETE,
CENTERLINE OF COLUMNS OR
CENTERLINE OF ROUGH
OPENINGS UNLESS NOTED
OTHERWISE.
BELLEVUE, WA 98004
A608
1 / A216 1 / A216 4. DOORS AND CASED OPENINGS
INDICATED ADJACENT TO WALL
MATCH LINE MATCH LINE INTERSECTIONS SHALL BE
M2
24' - 2"
6' - 2 1/2"
M2 W20 W26 LOCATED WITH THE EDGE OF
W26 W20
5' - 9"
W26 FINISHED OPENING SIX INCHES
FROM THE ADJACENT WALL AT
W26
G008 3 THE EXTERIOR AND FOUR INCHES
2' - 8 1/4"
W26 FROM THE ADJACENT WALL AT
29' - 0"
5 1/2"
INTERIOR LOCATIONS.
G1
3' - 3 3/4"
G1
3' - 7 1/4"
5. SEE SHEETS A222 - A225 FOR
24' - 3"
W20 W26
W20 CONCRETE DIMENSIONAL
REGISTERED
STATE OF WASHINGTON
ARCHITECT
CONTROL PLANS.
17' - 3 1/2"
TRAVIS McDANOLD
5' - 10 1/4"
UNIT B2
UNIT B2 6. SEE ENLARGED PLANS WHERE
5' - 0 5/8"
H G2 W20 430 H
ANSI TYPE ’B’ 418 REFERENCED FOR ADDITIONAL
A602 A602
4' - 6"
ANSI TYPE ’B’ N DIMENSIONS AND CALLOUTS.
10635
CEILING PLANS.
11' - 3 1/2"
J J
6' - 9 1/2"
8' - 6 3/4"
23' - 0"
23' - 0"
5 1/2"
5 1/2"
W20
W20
4' - 6"
UNIT B2 N
5' - 0 5/8"
3' - 7 1/4"
419 # DESCRIPTION DATE
429
5' - 10 1/4"
ANSI TYPE ’B’
17' - 3"
G2 W20 ANSI TYPE ’B’
24' - 3"
29' - 0"
6' - 2 1/2"
5 1/2"
24' - 2 1/2"
W26
W26 W26 W26 W20
PARTIAL PLAN − S
W20
FOURTH FLOOR
M2
5 1/2"
M2
K K
13' - 5 1/2"
13' - 5 1/2"
23' - 10"
16' - 10"
UNIT B1
UNIT B1 420
5' - 0 5/8"
ANSI TYPE ’B’
N
428
J ANSI TYPE ’B’ J
P
5 1/2"
A603 W26 W26 A603
6' - 10 1/4"
29' - 0"
49' - 0"
49' - 0"
9' - 8"
5 1/2"
9' - 8"
W20
W20
UNIT B1b
A501 2 UNIT B1 3
427 A502
5' - 0 5/8"
N
ANSI TYPE ’B’ 421 P
ANSI TYPE ’B’
16' - 10"
13' - 5 1/2"
5 1/2"
M2
M2
CENTER
W26
24' - 2"
W26
6' - 2 1/2"
5 1/2"
STAIR 3
ST403
6
24' - 2"
A612
5' - 8"
W20 W26
G1
24' - 3"
W20
M2
UNIT B2
5' - 6"
5' - 7"
422
24' - 9 1/2"
ST403 W26 N
5' - 8 1/2"
M M
7' - 0"
UNIT B9
FEC-1
426 W20
5 1/2"
ANSI TYPE ’B’ W26
3' - 5 1/2"
N
4' - 11 3/4"
J2
2' - 5"
W26
W20
W26
W26 4' - 9" 1' - 9"
5 1/2"
16' - 4"
P
UNIT B6
5' - 0 1/8"
33' - 4"
K K
W20 423
30' - 4"
W26 J2
32' - 3 1/2"
33' - 2 1/2"
18' - 9 1/2"
G2
UNIT B7
12' - 1 5/8"
UNIT B8 W26
425 424
ANSI TYPE ’B’ W20
ANSI TYPE ’B’
10' - 0"
7' - 7 1/2"
N N J7 P J2
W26
W20 PLOT DATE
W20 1/22/2021 1:06:13 PM
N N
8' - 0" 15' - 0" 8' - 6" 5' - 6" 10' - 3" 2' - 3" 6' - 6" 12' - 0" 6' - 6" DATE: 01/22/21
74' - 6" W20 SCALE: As indicated
1 4 N CHCKD: Checker
3' - 3 3/4"
4' - 8 1/2" 3' - 0" 8' - 6 1/2" 4' - 0" 8' - 6" 3' - 0" 8' - 11" 10' - 10" 3. ALL NON-ORTHAGONAL WALLS
21' - 7 1/2" 14' - 9" 5' - 9 1/2"
5' - 3" 2 A504
ARE 45° UNLESS NOTED
OTHERWISE.
BELLEVUE, WA 98004
W20 B
B B A601 4. DOORS AND CASED OPENINGS
W26 INDICATED ADJACENT TO WALL
17' - 0"
INTERSECTIONS SHALL BE
LOCATED WITH THE EDGE OF
11' - 3"
16' - 0"
R13 FROM THE ADJACENT WALL AT
511
W20 THE EXTERIOR AND FOUR INCHES
W20 FROM THE ADJACENT WALL AT
INTERIOR LOCATIONS.
6"
B2 M2 F2 F2 M2 B1
C C
35' - 10"
4' - 8 1/2"
5. SEE SHEETS A222 - A225 FOR
REGISTERED
STATE OF WASHINGTON
ARCHITECT
FEC-K CONCRETE DIMENSIONAL
UNIT B3
TRAVIS McDANOLD
CONTROL PLANS.
4' - 2 3/4"
W23 OHP24 OHP22 B1
W20 505
MUA2
ANSI TYPE ’B’ W26 6. SEE ENLARGED PLANS WHERE
W20 REFERENCED FOR ADDITIONAL
4' - 11 1/2"
19' - 9 1/2"
W20 DIMENSIONS AND CALLOUTS.
9' - 1"
OHP07
20' - 6"
10635
J13
CEILING PLANS.
5' - 0"
M2
34' - 0 1/2"
6' - 0"
MUA1
J13 DOAS1 Revision Schedule
7' - 0"
D W26
D # DESCRIPTION DATE
7' - 7"
J13
A602 W26 UNIT C1
531
530 506
5' - 0"
R11 14 P
ANSI TYPE ’B’
SERVERY TRASH W28 A920
62' - 0"
537 536 536 3' - 3 3/4" 19' - 3 3/4" 5' - 0 5/8" 6' - 11 7/8"
J13
5' - 3"
W27 W28 W26 CORR.
7' - 0"
502 W26
5 1/2"
A
3' - 3 1/4"
7' - 0"
2 502 W26
21' - 5 1/4"
A613 2 6' - 0 1/4"5 1/2" 8' - 9 3/4" 5' - 0 5/8"3' - 6 7/8" 5' - 11" A601
6 W27 A610
29' - 0"
LOBBY J2
42' - 2 1/2"
6' - 3 1/4"
J13 A609
530 KIT. OFF. W26
W27
PARTIAL PLAN − N
532 7' - 0 1/2"
7' - 0 3/4"
6' - 7 7/8"
3' - 0"
5' - 0"
534 533
FIFTH FLOOR
535 JAN. 8' - 2"
72' - 3 127/256"
17' - 11 3/4"
UNIT A3
9' - 4 3/4"
6' - 11 3/4" 533 ST502
4 508 DN
26' - 7"
J13 ACCESSIBLE
E 7' - 7" 11' - 10 1/4" 7' - 1"
E
6' - 6"
A716 8 507
10' - 8 1/2"
13' - 6 1/2"
5' - 0"
6' - 3 1/2"
19' - 9 1/2" 8' - 2" 34' - 0 1/2"
16' - 8"
5' - 0"
W20
J13 W28 W27
W27 J10 J10 J10 A709 9 W20 W20
6' - 6"
W30
F R11
4' - 1"
F
D M2 B1
W20
18' - 6"
4' - 6"
14
5' - 0"
7 W20 W20
DINING A611
3
509 3' - 0 1/4" 4' - 8 7/8" 5' - 7" 4' - 0" 5' - 7" 5' - 7" 4' - 0" 5' - 7" 3' - 8 1/4"3' - 0" 8' - 4 3/4" 4' - 8 1/2"
A606 A716 6
J13 J10
20' - 3"
7' - 1 1/4"
W30 W30 A308 B
6' - 6"
2' - 6 1/2"
W27 A601
CENTER
W28
A501 1 J13 J10
5' - 9 1/2"
9 PUB 510
2
512 3
9' - 9"
6' - 11 1/2"
A980
G 10 A716 12
G 5 6 7
9' - 2 1/2"
A503
W20 WOMENA709 15
5 1/2"
W23 W26
W26
M1
8' - 7"
UNIT A2 FEC-1
10' - 5 1/2"
14' - 0"
16' - 10"
G2 4
5 1/2"
W24 N C
A608
W23
48' - 11 1/2"
A601
9' - 7 1/2"
7' - 0"
5 1/2"
5 1/2"
514
W20
5 1/2"
W24
G2
UNIT C4 UNIT B1
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
R12 N
528 517
16' - 10"
5' - 0 5/8"
23' - 9 1/2"
H H
24' - 3"
3
W23 W26 A608
W26
21802.1
5' - 9"
R11
UNIT B2 PLOT DATE
518
ANSI TYPE ’B’ 1/22/2021 1:06:19 PM
W20
DATE: 01/22/21
SCALE: As indicated
DRAWN: Author
N CHCKD: Checker
BELLEVUE, WA 98004
A608
1 / A218 1 / A218 4. DOORS AND CASED OPENINGS
INDICATED ADJACENT TO WALL
MATCH LINE MATCH LINE INTERSECTIONS SHALL BE
M2 M2
6' - 2 1/2"
LOCATED WITH THE EDGE OF
W26 W20 FINISHED OPENING SIX INCHES
W26 W20
R11 FROM THE ADJACENT WALL AT
11' - 3"
G008 3 THE EXTERIOR AND FOUR INCHES
2' - 8 1/4"
FROM THE ADJACENT WALL AT
29' - 0"
W26
INTERIOR LOCATIONS.
W20
UNIT C4
3' - 3 3/4"
11' - 10 1/2"
G2 5. SEE SHEETS A222 - A225 FOR
528
24' - 3"
M2
W26 W20 CONCRETE DIMENSIONAL
ANSI TYPE ’B’
REGISTERED
STATE OF WASHINGTON
ARCHITECT
CONTROL PLANS.
TRAVIS McDANOLD
5' - 10 1/4"
W26 6. SEE ENLARGED PLANS WHERE
H UNIT B2 H
50' - 5 1/2"
5' - 0"
REFERENCED FOR ADDITIONAL
12' - 0"
A602 518 A602 DIMENSIONS AND CALLOUTS.
ANSI TYPE ’B’ N
R11
5 1/2"
7. SEE A400 SHEETS FOR REFLECTED
5 1/2"
10635
CEILING PLANS.
11' - 3 1/2"
J J
8' - 6 3/4"
35' - 0"
35' - 0"
23' - 0"
M2
W20
12' - 0"
UNIT B2 N
5' - 0"
# DESCRIPTION DATE
519
5' - 10 1/4"
ANSI TYPE ’B’
W20
CORR.
514
35' - 8"
24' - 3"
29' - 0"
6' - 0"
4' - 0"
G2
14' - 4"
6' - 2 1/2"
W26
24' - 3 1/8"
R12
5' - 0 5/8"
W26 W26 W20
UNIT C4
PARTIAL PLAN − S
527
5 1/2"
M2
FIFTH FLOOR
ANSI TYPE ’B’
F2
5 1/2"
W26
K K
13' - 5 1/2"
10' - 5"
16' - 10"
W23 UNIT B1
23' - 5 3/8"
5' - 0 5/8"
520
ANSI TYPE ’B’
J M2 J
5 1/2"
W26 N
A603 A603
6' - 10 1/4"
9' - 6"
29' - 0"
49' - 0"
9' - 8"
R11
A501 2 M2 3 A502
5' - 0 5/8"
36' - 11 3/4"
UNIT B1 N
521
16' - 10"
5' - 0"
W20 ANSI TYPE ’B’
11' - 7"
8' - 9 3/4"
5 1/2"
W23
L UNIT C11 L
F2 526
ANSI TYPE ’B’
M2
CENTER
24' - 2 5/8"
W26
6' - 2 1/2"
W26
93' - 6"
5 1/2"
R12
14' - 3"
W26
6' - 0"
18' - 6 3/4"
G2
24' - 3"
2 W20
K2
A612
UNIT B2
17' - 3 1/2"
DN
5' - 7"
STAIR 3 522 W20
ST503 ANSI TYPE ’B’
11' - 3 1/2"
5' - 0"
N
14' - 8"
5' - 8 1/2"
ST503
M M
5 1/2"
R11
6' - 5 7/8"
4' - 11 3/4"
3' - 5 5/8"
F2 J2
W26 W20
42' - 7 1/4"
5' - 1 3/8"
W23 W26
UNIT C5 6' - 8"
525
11' - 3"
ACCESSIBLE UNIT B6
5' - 0 1/8"
K N K
523
30' - 4"
F2
32' - 3 1/2"
33' - 2 1/2"
33' - 2 1/2"
UNIT B7 J2
W20 524
12' - 1 1/2"
ANSI TYPE ’B’
10' - 0"
W26
R12 W26 W20
JOB NO.:
N N 21802.1
7' - 7 1/2"
L L P J2 W26
W20 W20 PLOT DATE
1/22/2021 1:06:24 PM
M2 M2
W20 DATE: 01/22/21
7' - 0" 12' - 0" 8' - 6" 5' - 6" 10' - 3" 1' - 3" 6' - 6" 12' - 0" 6' - 6"
SCALE: As indicated
45' - 6" 25' - 0"
DRAWN: Author
20' - 0" 26' - 0" 22' - 0"
1 N CHCKD: Checker
1
A219
5TH FLOOR - SOUTH
1/8" = 1'-0"
A A219
t: 425-453-0606
www.wattenbarger.com
1 2 3 4 5 6 7
E D
A602 A601
1/4" / 1'-0"
B B
1/4" / 1'-0"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
2' - 0"
TRAVIS McDANOLD
R14
C C
3" / 12"
5" / 12"
5" / 12"
3/8" / 1'-0"
R4
12' - 0 1/8"
3' - 0"
10635
CRICKET
R7
KEF2 KEF1
1/4" / 1'-0"
CRICKET Revision Schedule
3" / 12"
R8
1' - 6"
5" / 12"
R4 R4 # DESCRIPTION DATE
1/4" / 1'-0"
1' - 0"
R8
1/4" / 1'-0"
D D
F
36' - 0"
A602
R8 20' - 0 1/2" 3' - 0"
1/4" / 1'-0"
16' - 2"
1/4" / 1'-0"
3/8" / 1'-0" 1/4" / 1'-0" 3" / 12"
1/4" / 1'-0"
3" / 12"
R4
1/4" / 1'-0"
NORTH
1/4" / 1'-0"
3" / 12"
1/4" / 1'-0" 1/4" / 1'-0" R4
R7
1/4" / 1'-0"
CRICKET
1/4" / 1'-0"
5" / 12"
5" / 12"
R10 R10
E E
R4
5" / 12"
CRICKET
3" / 12"
R4
3" / 12"
13' - 9 1/2"
R7 R5
3" / 12"
R4 R4
2' - 0"
2' - 0"
2' - 0"
2' - 0"
1/4" / 1'-0"
1' - 6"
3 1' - 6" 1' - 6" 1' - 6" 1' - 6"
CENTER
A606
R7
1/4" / 1'-0"
R7 8' - 0"
1/4" / 1'-0"
B
1' - 4 1/2"
A601
G 1/4" / 1'-0"
G 5 6 7
5" / 12"
R6
R4
ATTIC
ACCESS
HATCH.
SEE DETAIL AREA: 507.1 ft² AREA: 142.5 ft²
VOL: 396.3 ft³ VOL: 66.7 ft³
5" / 12"
R4
1 / A221 1 / A221 AREA: 84.5 ft²
VOL: 33.5 ft³ AREA: 3.1 ft² AREA: 25.5 ft² PLOT DATE
R4
AVG. THICK.: 3.51 in VOL: 0.8 ft³ VOL: 20.3 ft³ 1/22/2021 1:06:28 PM
AVG. THICK.: 2.00 in AVG. THICK.: 8.30 in
5" / 12"
R4
3" / 12"
5" / 12"
DATE: 01/22/21
2 TAPERED ROOF INSULATION AVG. DEPTH SCALE: As indicated
A220 1" = 20'-0" DRAWN: Author
N
CHCKD: Checker
1
A220
ROOF PLAN
1/8" = 1'-0"
A A220
t: 425-453-0606
www.wattenbarger.com
1 2 3 4
R4
5" / 12"
BELLEVUE, WA 98004
A608
1 / A220 1 / A220
5" / 12"
MATCH LINE MATCH LINE
3" / 12"
R4
R6
5" / 12"
4' - 0" 8' - 0"
R4
D.S.
5" / 12"
3' - 0" D.S.
6' - 0"
3' - 0"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
H
A602
D.S.
R4
10635
J J
35' - 0"
23' - 0"
3" / 12"
3" / 12"
R4
Revision Schedule
# DESCRIPTION DATE
3' - 0"
D.S.
1/4" / 1'-0"
6' - 0"
5" / 12"
3' - 0"
D.S.
1' - 0"
5" / 12"
4' - 0"
8' - 0"
5" / 12"
5" / 12"
K K
SOUTH
R6 R4
35' - 3"
3" / 12"
3" / 12"
J
A603
ATTIC ACCESS
R4
D.S. HATCH. SEE DETAIL
5" / 12"
5" / 12"
R4
13' - 9"
5" / 12"
R4
CENTER
5" / 12"
93' - 6"
R4
RTU2 8' - 0"
6' - 0"
ATTIC ACCESS
HATCH. SEE DETAIL
R4
1/4" / 1'-0" 11
1/4" / 1'-0"
A912 3' - 0"
TYP
11' - 3 1/2"
36" x 48" ROOF
5" / 12"
R6
ACCESS HATCH R4
D.S.
M 5' - 0" 3' - 0"
M
1/4" / 12"
5" / 12"
D.S.
5" / 12"
5" / 12"
3" / 12"
5" / 12"
5" / 12"
K
A603
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
5" / 12"
3" / 12"
33' - 2 1/2"
5" / 12"
R4
R4
5" / 12"
JOB NO.:
N N 21802.1
2' - 0"
D.S.
DATE: 01/22/21
1' - 6" 25' - 0" 1' - 6" SCALE: 1/8" = 1’−0"
DRAWN: Author
N
CHCKD: Checker
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
32' - 0 1/2"
10635
9' - 2"
6 6 Revision Schedule
10' - 11 3/4"
# DESCRIPTION DATE
W2-12
12' - 0"
37' - 0"
29' - 0"
29' - 9 1/2"
5 5
BASEMENT
W2-12
11' - 6"
W2-10 W02
16' - 3 3/8" 7 7/8" W2-12 W2-12
G H J K L M N
30' - 8 1/2"
179' - 9"
9' - 5" W1-12 W1-12
87' - 9" 8' - 0" 28' - 0" 8' - 0" 46' - 0" 6' - 1"
23' - 3"
1' - 0"
9' - 5" 1' - 9"
W2-10
W1-12 W1-12
W2-12
32' - 0"
UP W2-12
1' - 8 1/2"
W1-12
4 W2-12 W2-12
4
7' - 9"
W2-12 W1-12 W1-12 W1-8
5' - 0"
6' - 8"
W2-12
W1-8 W1-8
7' - 8" 12' - 0"
20' - 6" 9' - 4"
CENTER
6' - 0 7/8"
6"
15' - 7 3/4"
W1-12
W1-8
W2-12
3 3
48' - 0"
W1-12
24' - 9"
26' - 0"
W1-12
W1-12
W1-12
38' - 0"
53' - 7"
W1-8
2' - 3"
1' - 3"
1' - 0"
1' - 0"
2 2
W2-10 W2-12
W2-12
14' - 2"
W2-12
20' - 4"
20' - 4"
19' - 4"
20' - 0"
20' - 0"
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
1 1
6' - 3"
5' - 7"
W1-10 W1-8
JOB NO.:
3' - 6" 8' - 6" 57' - 0" 52' - 2"
29' - 10"
12' - 0" 21802.1
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4"
260' - 9" PLOT DATE
1/22/2021 1:06:34 PM
A B C D E F G H J K L M N DATE: 01/22/21
SCALE: 3/32" = 1’−0"
DRAWN: DH
CHCKD: TM
1
A222
BASEMENT FLOOR SLAB EDGE PLAN
3/32" = 1'-0"
A A222
t: 425-453-0606
www.wattenbarger.com
C D E F
W1-12
W2-12 W2-12
2' - 8 1/2"
7 7
REGISTERED
STATE OF WASHINGTON
ARCHITECT
TRAVIS McDANOLD
W1-12
W1-12
W2-8
32' - 0 1/2"
10635
10' - 7 1/2" W1-8
29' - 4"
14' - 3 3/8"
Revision Schedule
# DESCRIPTION DATE
6 6
70' - 1 1/4"
16' - 0 1/4"
W2-8
12' - 0" 4' - 0 1/4"
29' - 0"
W2-12
21' - 0" 1' - 0"
W2-12
5 5
11' - 9 1/4"
W2-12 W2-12 G H J K L M N
A B
30' - 8 1/2"
W1-12
W1-12 W2-8
4 W2-12
4
W2-12 W1-8
7' - 9"
5' - 3"
87' - 9" 15' - 8"
W2-12
CENTER
20' - 0" 9' - 4"
22' - 0"
6' - 8"
W2-8 W1-8
W2-8
9' - 8 1/2"
W2-12
W2-8
30' - 9 7/8"
26' - 0"
1' - 0"
1' - 0"
2 DN 2
W2-10 W2-12
W2-12
14' - 2"
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
W2-12
20' - 0"
19' - 0"
19' - 0"
20' - 0"
PLOT DATE
W2-12
1/22/2021 1:06:37 PM
DATE: 01/22/21
5' - 3" 11' - 3" 20' - 6" 29' - 0" 13' - 0" 20' - 3" 33' - 0" 29' - 0" 29' - 0" 29' - 0" 24' - 2" 30' - 4" SCALE: 3/32" = 1’−0"
1
A223
1ST FLOOR SLAB EDGE PLAN
3/32" = 1'-0"
A A223
t: 425-453-0606
www.wattenbarger.com
C D E F
2' - 8 1/2"
7 7
15' - 10 3/8"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
W2-12
TRAVIS McDANOLD
32' - 0 1/2"
10635
Revision Schedule
6 6 # DESCRIPTION DATE
15' - 11 5/8"
W2-12
SECOND FLOOR
20' - 0"
W2-12
5 5
W2-12
W2-12 W2-12
A B H J K L M N
30' - 8 1/2"
9' - 5"
23' - 3"
9' - 5"
G
W2-12 W2-12
4 W2-12 4
W2-12
CENTER
6' - 0 7/8"
3 3
W2-12 W2-12
7' - 8"
26' - 0"
1' - 0"
1' - 0"
2 2
20' - 0"
20' - 0"
19' - 0"
19' - 0"
19' - 0"
20' - 0"
1 1
57' - 0" 52' - 2" 28' - 10"
PLOT DATE
1/22/2021 1:06:40 PM
DATE: 01/22/21
SCALE: 3/32" = 1’−0"
DRAWN: Author
CHCKD: Checker
1
A225
1
2
3
4
5
6
7
20' - 0" 26' - 0" 22' - 0" 30' - 8 1/2" 29' - 0" 32' - 0 1/2"
3/32" = 1'-0"
48' - 0"
2' - 0" 18' - 0" 4' - 0"
A
A
B
B
9"
48' - 5 1/2"
8' - 6 1/2" 9' - 5 1/2" 8' - 3 1/2" 51' - 0 1/2" 1' - 8 1/2"
11' - 3"
C
C
28' - 6"
20' - 6"
20' - 9 1/2"
2' - 6"
D
D
29' - 0"
42' - 2 1/2"
E
E
13' - 0"
F
F
20' - 3"
5
6
7
G
G
21' - 6"
15
'-
6"
33' - 0"
48' - 6"
9' - 0"
2' - 6"
H
H
273' - 9"
13' - 0"
29' - 0"
J
J
63' - 0"
29' - 0"
10' - 0"
K
K
2' - 6"
29' - 0"
24' - 0"
49' - 0"
2' - 6"
L
L
10' - 0"
24' - 2"
M
M
3' - 1 1/2"
30' - 4"
27' - 2 1/2"
9"
N
N
6' - 0"
9" 20' - 9" 26' - 0" 3' - 6" 18' - 6" 6' - 6"
50' - 3"
10635
BROWNS POINT TOWN
BLDG.
DATE:
REGISTERED
SCALE:
CHCKD:
DRAWN:
ARCHITECT
JOB NO.:
STATE OF WASHINGTON
1008 TOWN CENTER NE, TACOMA, WA 11000 N.E. 33RD PL., SUITE #102 t: 425-453-0606
DATE
1/22/2021 1:06:44 PM
21802.1
Checker
Author
A A225
01/22/21
3/32" = 1’−0"
SHEET NO.:
1' - 0"
DF-1 ELKAY LZWS-EDFP2 Drinking Fountain
17K
1' - 0"
DR-1 MFR MODEL Electric residential top load
clothes dryer, long vent
DR-2 MFR MODEL Electric Commercial top load
clothes dryer, long vent
3' - 9 1/2"
3' - 9 1/2"
BELLEVUE, WA 98004
Swivel
FAU-1 MFR MODEL Pull Out Kitchen Faucet
2' - 3 5/8" 2' - 3 5/8" FAU-2 MFR MODEL Two Handle Centerset
Lavatory Faucet
SLEEPING AREA SLEEPING AREA
14' - 3"
14' - 3"
SLEEPING AREA SLEEPING AREA
14' - 3"
14' - 3"
FAU-3 MFR MODEL Gooseneck wetbar faucet,
ANSI A117.1 / ADA
UNIT UNIT MC2 UNIT compliant faucet handle
UNIT MC1 MC1−b
ANSI TYPE ’B’ MC2−b FAU-4 MFR MODEL Faucet
382 SF ANSI TYPE ’B’ FAU-5 MFR MODEL pulldown kitchen faucet,
ANSI TYPE ’B’ ANSI TYPE ’B’ W13
386 SF 386 SF ANSI A117.1 / ADA
386 SF
W13 compliant faucet handle
4' - 8 3/8" 1' - 2 1/4" 3' - 10" 3' - 11 7/8" 6' - 9 1/2" 6' - 11 1/2"
FAU-6 MFR MODEL Gooseneck Utility Faucet
REGISTERED
STATE OF WASHINGTON
ARCHITECT
1' - 0 3/4" 1' - 0 3/4"
TRAVIS McDANOLD
FAU-7 MFR MODEL Wall mount Mop Sink Faucet
1' - 2 1/4"
3' - 10" 3' - 11 7/8" 3' - 11 7/8" 3' - 10"
W15 FEC-1 MFR MODEL Fire Extinguisher Cabinet,
W2-12 W13
W15 W18 semi-recessed
FEC-2 MFR MODEL Fire Extinguisher Cabinet,
29' - 11"
29' - 11"
U8 U8 U8 U8
2' - 4 7/8"
W14 Surface Mount
W14 CLOSET CLOSET
2' - 5"
2' - 5"
1' - 2 5/8"
W14 CLOSET CLOSET FEC- MFR MODEL Fire Extinguisher Cabinet,
10635
W15 W15 W15 K semi-recessed, Class K
(Kitchen)
W15 FS MIFAB FS1734 12 x 12 x 8 DEEP FLOOR
W18 W18 WC-2 WC-2 SINK
4' - 4 7/8"
W18 W18 LAV-2 5 ENTRY
BATH #1 7' - 8" GB-1 BOBRICK 580616 18" Vertical Grab Bar
5' - 0 1/4"
FAU-2 GB-2 BATH #2 Revision Schedule
GB-2 GB-2 GB-2 BOBRICK 580616 24" Grab Bar
7' - 5 1/8"
6 A702 7 8 W19 GB-3 BOBRICK 580616 36" Grab Bar
ENTRY GB-2 TP-2 # DESCRIPTION DATE
TP-2 WC-2 WC-2 TP-2
U11
GB-4 BOBRICK 580616 42" Grab Bar
10' - 0"
10' - 0"
1 TP-2 RK-1 9 A702 11 LAV-1 MFR MODEL 20 inch x 17 inch Oval
4' - 8 3/8" TB-1
Lavatory
1' - 10 3/8"
ENTRY ENTRY 9 5/8" 2' - 0 1/4" LAV-2
2 A702 4
5' - 7 1/4"
U11
BATH #2 BATH #1 10
RK-1 RK-1 W15 W13 LAV-3
1' - 7 1/4"
OPP. AT W15 W15
U11
U11
U11
BATH 2 LIN-1 ClosetMaid ExpressShelf Linen Pantry
U11
3
U11
U11
SHOWER Shelving
TB-1 SHOWER TB-1
W18 W18 TB-1 LIN-2 ClosetMaid ExpressShelf Linen Pantry
Shelving
U1
5' - 10"
U1 U1 U1 LAV-2 FAU-2
LIN. LIN. LINEN MW-1 PANASONI NN-CD87KS Microwave Oven +
EL EN
S
SHELVES
VE
SHELVES SHELVES W18 C NN-TK81KCS Trim Kit
8"
SH LIN
7/
3' - 3"
3' - 3"
3' - 3"
2' - 1 3/4"
6 1/2" SH-3 MW-2 countertop microwave oven
1
SH-3
-1
8 "
UNIT RM.
1/
MW-3 MFR MODEL Microwave Oven
4'
4
NAME NO. PTD-1 BOBRICK B-4262 Paper Towel Dispenser
UNIT PLANS
"8
UNIT MC1 139 PTW- BOBRICK B-38032 Semi-Recessed Combination
2' - 1 3/4"
7/
1 Towel and Waste Unit
-4
UNIT MC1-b 140 W18 W18
PER SHWR MFR. W13
2'
UNIT RM. REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
UNIT MC1 141 PER SHWR MFR. refrigerator
UNIT MC1-b 142 2' - 2 7/8" 6' - 7 3/4" 2' - 2 5/8" NAME NO. 11 5/8"
2' - 6 3/8" 6' - 4" 3' - 7 1/4" 2' - 2 3/4" REF-2 MFR MODEL Side by Side Refrigerator
UNIT MC1 143 5' - 8 1/4" 3' - 3" 11' - 1 3/8" 3' - 3" 5' - 8 1/2" UNIT MC2 109
REF-3 U-LINE ADA24RGL Under Counter refrigerator,
UNIT MC1-b 144 UNIT MC2-b 110 5' - 6 1/2" 3' - 3" 14' - 8 3/8" 5' - 6 1/8"
29' - 0" 32" height
UNIT MC1 145 UNIT MC2 113 29' - 0" RH-1 MFR MODEL 30" range hood
UNIT MC1-b 146 UNIT MC2-b 114 RK-1 MFR MODEL Robe Hook
8 4 RNG- MFR MODEL 30" residential slide-in range
1
1 UNIT MC1 - SUITE 2 UNIT MC2 - SUITE RNG- MFR MODEL 30" residential drop-in range
A301 1/4" = 1'-0" A301 1/4" = 1'-0" 2
SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
& FIRE Horizontal Curtain
30' - 6" 29' - 4"
SCD- BOBRICK B-301 Recessed Seat Cover
12' - 7 3/8" 8' - 11 1/2" 7' - 0 1/2" 1 Dispenser
1' - 0"
14' - 0" 8' - 3" 7' - 3" 3" 5 5/8" SD-1 Bobrick B-2111 ClassicSeries®
Surface-Mounted Soap
1' - 0"
LAV-2 Drain, Beveled Threshold
SH-2 BEST BATH 4LBS24836F 4-Piece 36x48 Fiberglass
3' - 0"
CENTER
3 5/8"
5 5/8"
W15 W18 1FTB Shower Enclosure w/ Trench
U8 Drain, Beveled Threshold
W17 SH-3
W15 SK-1 MFR MODEL Undermount 17x22 S.S.
6' - 3 1/4"
7' - 0 1/2"
W15 Single Bowl Sink
TP-2 SK-2 MFR MODEL Undermount 17x22 S.S.
1 Single Bowl Sink, roll-under
SLEEPING AREA GB-4 RK-1 SHOWER depth
U11
SLEEPING AREA SLEEPING AREA SK-3 MFR MODEL Drop-in 33x22 S.S. Double
2 A703 3
RK-1 Bowl Sink
13' - 5 5/8"
12' - 8"
8' - 11 1/2"
23' - 9 3/8"
6" W15 SK-8 MFR MODEL 24"x 24" Floor Mop Sink
2' - 6" 5' - 0 3/8" 5' - 6" 4' - 3" 6' - 2" 5' - 1" W17
W15 A990 SN-1 BOBRICK B-254 Surface Mounted Sanitary
BATH
Napkin Disposal
WC-2 U2
W18 W14 2 SST-1 BEST BATH - ADA SHOWER SEAT
"
-9
26' - 7"
30' - 3"
TP-2 TB-1 MFR MODEL 24" Towel Bar
3'
W14 29' - 3" GB-3
GB-4 TP-1 BOBRICK B-27313 Surface Mounted Toilet
GB-2 WC-2
2' - 6"
"
W18
2
5' - 6" U8
2' - 1 5/8"
W15
1/
W15 TP-2 MFR Toilet Paper Holder
-4
SHELVES
W15
3'
T
LAV-2
SE
spud high efficiency small
3' - 1 1/4"
W19 W15
LO
FAU-2 BATH #2 2' urinal.
GB-2 -6
C
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
9' - 10 3/8"
16 W13 " 6' - 1 1/4" WA-1 MFR MODEL residential top load washing
ENTRY BATH #1 W15 TP-2 machine
W15
"
TP-2
6' - 10 7/8"
-0
W15
6' - 1 1/4"
CLOSET
T
U11
17 19
7'
SE
W18 ENTRY machine
LO
W18
U11
U11
SLEEPING AREA
C
12 WA-3 UNIMAC As Specified Commercial
U8
4' - 1"
12' - 6 3/8"
18 Washer/Extractor
7' - 0 1/8"
RK-1 U8
U11
3' - 6"
1' - 3"
U1 U1 U1
TB-1 LIN UNIT WD-1 WHIRLPOO
UNIT PLAN WETLV27HW
GENERAL NOTES: 27" Long Vent Laundry
14 SHVS L Center
MC4−b JOB NO.:
3' - 3"
3' - 3"
5' - 8"
21802.1
2. PLAN DIMENSIONS ARE TO FACE OF STUD, FACE
5' - 2"
W18 388 SF
OF CONCRETE, CENTERLINE OF COLUMN, OR
U1 CENTERLINE OF ROUGH OPENINGS, UNLESS PLOT DATE
NOTED OTHERWISE. CONTACT ARCHITECT FOR
W15
3"
LAV-2 CLARIFICATIONS. 1/22/2021 1:06:54 PM
3. DOORS AND CASED OPENINGS INDICATED
1' - 2 3/8" FAU-2
ADJACENT TO WALL INTERSECTIONS SHALL BE DATE: 01/22/21
LOCATED WITH THE EDGE OF FINISH OPENING 6"
UNIT RM. 2' - 5 3/8" 5' - 1" 4' - 10 7/8" PER SHWR MFR. UNIT RM. W13 FROM THE ADJACENT WALL AT THE EXTERIOR SCALE: As indicated
NAME NO. 3" 8' - 8 3/4" 11' - 0 5/8" 3' - 3" 6' - 11 5/8" 3" NAME NO. AND 4" FROM THE ADJACENT WALL.
4. SEE A800 SERIES SHEETS FOR DOOR, WINDOW & DRAWN: ALL
UNIT MC3 131 UNIT MC4 111
30' - 6" 5' - 3" 24' - 1" WALL SCHEDULES CHCKD: TM
UNIT MC3-b 132 UNIT MC4-b 112 5. INSTALL BLOCKING FOR GRAB BARS IN ALL
UNIT MC3 133 UNIT MC4 137 29' - 4" BATHROOM WALLS SURROUNDING WATER
UNIT MC3-b 134 UNIT MC4-b 138 CLOSET, BATHTUB AND SHOWERS; REFER TO BLDG. SHEET NO.:
4 4 SHEETS A701 & A702.
3
A301
UNIT MC3 - SUITE
1/4" = 1'-0"
4
A301
UNIT MC4 - SUITE
1/4" = 1'-0"
6. FLOOR FINISH TO CONTINUE UNDER ALL
REMOVEABLE CASEWORK AND OPEN BELOW
WORK SURFACES AT ACCESSIBLE & TYPE 'A'
UNITS.
A A301
t: 425-453-0606
www.wattenbarger.com
FIXTURES, APPLIANCES & ACCESSORIES
17' - 0 3/4"
3"
14' - 2" MA BASIS OF DESIGN
7 5/8" 16' - 2 1/8" 22' - 3"
16' - 2" RK MFR MODEL DESCRIPTION
1' - 0"
10' - 5" 5' - 7" 6' - 3"
5' - 9 3/8"
5' - 9 3/8"
8' - 7 1/4"
SLEEPING AREA DW-2 MFR MODEL 24" dishwasher, 32" height
SLEEPING AREA LIVING AREA
BELLEVUE, WA 98004
EW-1 GUARDIAN G1806 Eyewash, Deck Mounted, 90º
Swivel
13' - 10 1/4"
W15 FAU-1 MFR MODEL Pull Out Kitchen Faucet
1' - 1 7/8" UNIT MC6
UNIT MC7 FAU-2 MFR MODEL Two Handle Centerset
14' - 2 1/4"
4' - 1 3/4"
4' - 1 3/4"
SLEEPING AREA ANSI TYPE ’B’
UNIT A1 Lavatory Faucet
W15
17' - 2 1/4"
391 SF ANSI TYPE ’B’
17' - 11 3/4"
468 SF FAU-3 MFR MODEL Gooseneck wetbar faucet,
A990 1 399 SF ANSI A117.1 / ADA
2' - 0"
W18 compliant faucet handle
CLOSET FAU-4 MFR MODEL Faucet
4' - 1"
W18 UNIT MC5 U3 FAU-5 MFR MODEL pulldown kitchen faucet,
3' - 10 3/4"
ANSI TYPE ’B’
4' - 1 3/4"
1 A990 3' - 6" 2' - 11" W15 ANSI A117.1 / ADA
SLEEPING AREA
430 SF compliant faucet handle
24' - 0"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
W15 FAU-6 MFR MODEL Gooseneck Utility Faucet
TRAVIS McDANOLD
26' - 8"
7 1/4" FAU-7 MFR MODEL Wall mount Mop Sink Faucet
3"
2' - 8 1/2" 4' - 3 3/4" 3' - 8 1/2" 5' - 5 3/4" U8
28' - 3"
U8 FEC-1 MFR MODEL Fire Extinguisher Cabinet,
W15 EQ EQ REF-1
CLOSET
30' - 0"
2' - 5 5/8"
2' - 5 5/8"
semi-recessed
W15 CLOSET
FEC-2 MFR MODEL Fire Extinguisher Cabinet,
W15 W15
31' - 1"
10635
EQ
2' - 10 1/4"
W18
3' - 2"
3' - 2"
A990 W18 (Kitchen)
7' - 1"
5' - 4"
MFR SK-1 SINK
U8 1 W19 A710 1 GB-1 BOBRICK 580616 18" Vertical Grab Bar
EQ
14' - 4 3/4"
Revision Schedule
16' - 9 3/4"
3' - 2 1/2"
3' - 7 1/4"
3' - 7 1/4"
3' - 4 1/4"
W15 W14 # DESCRIPTION DATE
BATH 7 10 GB-3 BOBRICK 580616 36" Grab Bar
8' - 8 1/4"
U11 FAU-2 W18 WD-1
ENTRY W18 FAU-2 W15 GB-4 BOBRICK 580616 42" Grab Bar
2' - 6 1/2"
U11
U1 SH-1
SHELVES
4' - 11 1/4"
4' - 11 1/4"
TB-1 11 LAV-3
1' - 9 1/4"
6' - 7 1/4"
3' - 5"
3' - 8"
UNIT PLANS
13' - 9 1/2" WC-1 FAU-2 LAV-1 PTD-1 BOBRICK B-4262 Paper Towel Dispenser
UNIT A1 229
UNIT A1 240 PTW- BOBRICK B-38032 Semi-Recessed Combination
7' - 11" 6' - 3" 1 Towel and Waste Unit
UNIT A1 241
PER SHWR MFR 3' - 5" 5' - 3 3/8" 3" REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
UNIT A1 246 14' - 2" refrigerator
UNIT A1 247
UNIT RM. UNIT RM. UNIT RM. REF-2 MFR MODEL Side by Side Refrigerator
UNIT A1 248
REF-3 U-LINE ADA24RGL Under Counter refrigerator,
NAME NO. NAME NO. NAME NO. UNIT A1 249 32" height
UNIT MC5 136 UNIT MC6 108 UNIT MC7 107 UNIT A1 250 RH-1 MFR MODEL 30" range hood
1 1 1 11 RK-1 MFR MODEL Robe Hook
RNG- MFR MODEL 30" residential slide-in range
1 UNIT MC5 2 UNIT MC6 3 UNIT MC7 4 UNIT A1 1
A302 1/4" = 1'-0" A302 1/4" = 1'-0" A302 1/4" = 1'-0" A302 1/4" = 1'-0" RNG- MFR MODEL 30" residential drop-in range
2
SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
UNIT RM. & FIRE Horizontal Curtain
NAME NO. SCD- BOBRICK B-301 Recessed Seat Cover
17' - 3 1/2"
UNIT B1 316 1 Dispenser
8' - 0 1/2" 3' - 3 1/2" 5' - 6" 14' - 8 1/2" 2' - 11 1/2" 2' - 7" 3' - 2 1/2" UNIT B1 317 SD-1 Bobrick B-2111 ClassicSeries®
24' - 3"
1' - 8 1/2"
UNIT B1b 327 SH-1 BEST BATH LES24038A7 1-Piece 36x36 Fiberglass
5FTT Shower Enclosure w/ Trench
UNIT B1 328 Drain, Beveled Threshold
U12
UNIT B1 331
3' - 6 1/4"
SH-2 BEST BATH 4LBS24836F 4-Piece 36x48 Fiberglass
3' - 2"
4' - 1"
UNIT B1 335
CENTER
UNIT B1 416 SH-3 BEST BATH 5LES26337A 5-Piece 60x36 Fiberglass
UNIT B1 417 1FTB Shower Enclosure w/ Trench
UNIT B1 420 2' - 3 1/2" Drain, Beveled Threshold
W28 SK-1 MFR MODEL Undermount 17x22 S.S.
14' - 2 1/2"
11' - 4"
UNIT B1 421
CLOSET Single Bowl Sink
5' - 8"
17' - 8 1/2"
UNIT B1 432 SK-3 MFR MODEL Drop-in 33x22 S.S. Double
9' - 11 1/2"
UNIT B1 435 Bowl Sink
SLEEPING AREA
UNIT B1 516 SK-4 MFR MODEL Drop-in 17x19 S.S. Single
11' - 4" 5' - 6" W28
UNIT B1 517 Bowl Bar Sink
UNIT A2 W28
W28
UNIT B1 520 SK-5 MFR MODEL Activity room Sink, TBD
ANSI TYPE ’B’ UNIT B1 521 SK-6 MFR MODEL Laundry/Utility Sink
490 SF 2' - 9 1/2" 22 SK-7 AMERICAN 9504.999 'CLINIC SERVICE SINK'
W28
29' - 8 1/2"
6' - 1"
ANSI TYPE ’B’ SN-1 BOBRICK B-254 Surface Mounted Sanitary
30' - 0"
MW-1 590 SF
633 SF Napkin Disposal
3' - 9"
SLEEPING AREA U2 SST-1 BEST BATH - ADA SHOWER SEAT
33' - 6 1/2"
W28 W28
MW-1 KITCHEN 2' - 2" 8' - 7" TB-1 MFR MODEL 24" Towel Bar
W28 W28
5' - 11 1/2"
W30 TP-1 BOBRICK B-27313 Surface Mounted Toilet
Tissue Cabinet
W28 PER SHWR FAU-1 CLOSET
12' - 2 1/2"
3' - 8"
U2 UR-1 SLOAN SU-7009-A Complete Vitreous China top
CLOSET U4 WD-1 spud high efficiency small
FAU-1 U2
11' - 10"
6' - 0"
6' - 0"
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
1 A710 W27
22' - 8"
SH-2 U2 MFR W28 W28 WA-2 MFR MODEL Commercial top load washing
SIM. U9 WA-1 REF-1 machine
REF-1
1' - 3"
U2 16 TB-1 1 U11 U11 WA-3 UNIMAC As Specified Commercial
10' - 4 1/2"
GB-4 Washer/Extractor
W27 W28
5' - 9 3/4"
REF-1 TP-2 SH-2 SH-2 KITCHEN WC-1 MFR MODEL 17" elongated bowl toilet
16' - 7"
7' - 0"
W28 RNG-1 WD-1 WHIRLPOO WETLV27HW 27" Long Vent Laundry
BATH U6 BATH JOB NO.:
12' - 2"
W28 17 3 L Center
GB-2 5
CLOSET
8' - 10 1/2"
10' - 7"
U1 W28 U2
U2
2' - 0 1/8" TB-1 TB-1 6 A704 8 PLOT DATE
U1 WC-2 GB-3 FAU-1
3' - 0" 5' - 7 1/2" 4' - 3" 10' - 7" TP-2 ENTRY 1/22/2021 1:07:09 PM
TP-2 7 SK-1
FAU-2 LAV-1 23' - 5 1/2"
GB-2 CL. U6 GB-2
3' - 7"
W28 DATE: 01/22/21
2 3/4" 2 3/4"
2' - 9 1/2" 5' - 5 1/2" 8' - 7" SCALE: 1/4" = 1’−0"
WC-1 WC-1
U1 DRAWN: Author
UNIT RM. UNIT RM. LAV-1 FAU-2 CHCKD: Checker
NAME NO. NAME NO. 8' - 1 1/4" 2' - 7 3/4" 8' - 6 1/4" 8' - 9 1/4"
UNIT A2 529 UNIT A3 508 10' - 9" BLDG. SHEET NO.:
1 1 UNIT B1b BATH
5
A302
UNIT A2
1/4" = 1'-0" A302
6 UNIT A3
1/4" = 1'-0"
7
A302
UNIT B1
1/4" = 1'-0"
A A302
t: 425-453-0606
www.wattenbarger.com
FIXTURES, APPLIANCES & ACCESSORIES
MA BASIS OF DESIGN
RK MFR MODEL DESCRIPTION
1' - 0" 2 3/4" 24' - 0" DF-1 ELKAY LZWS-EDFP2 Drinking Fountain
2 3/4" 6' - 11 1/2" 5' - 0" 11' - 3 1/2"
2 3/4" 2 3/4" 17K
10' - 3" 3' - 0 1/8" 10' - 3 3/8" 4' - 2 3/8" 23' - 0 5/8"
DR-1 MFR MODEL Electric residential top load
3" 12' - 6 5/8" 10' - 0" 3" clothes dryer, long vent
DR-2 MFR MODEL Electric Commercial top load
3' - 2 1/2"
BELLEVUE, WA 98004
EW-1 GUARDIAN G1806 Eyewash, Deck Mounted, 90º
3' - 9 1/2"
W15 Swivel
1' - 4"
FAU-1 MFR MODEL Pull Out Kitchen Faucet
W28
12' - 5"
FAU-2 MFR MODEL Two Handle Centerset
12' - 9"
LIVING ROOM BEDROOM
11' - 0"
Lavatory Faucet
11' - 7"
BEDROOM LIVING ROOM FAU-3 MFR MODEL Gooseneck wetbar faucet,
LIVING ROOM ANSI A117.1 / ADA
compliant faucet handle
11' - 4"
FAU-4 MFR MODEL Faucet
FAU-5 MFR MODEL pulldown kitchen faucet,
W28 1' - 3 3/4" W15
W28 5' - 5 1/2" 5' - 10" ANSI A117.1 / ADA
4' - 9" compliant faucet handle
REGISTERED
UNIT B3
STATE OF WASHINGTON
ARCHITECT
FAU-6 MFR MODEL Gooseneck Utility Faucet
11' - 4"
W28
TRAVIS McDANOLD
BEDROOM ANSI TYPE ’B’
UNIT B2 U3 FAU-7 MFR MODEL Wall mount Mop Sink Faucet
23' - 9"
1' - 6"
U3 626 SF
ANSI TYPE ’B’ W28 FEC-1 MFR MODEL Fire Extinguisher Cabinet,
27' - 6"
semi-recessed
29' - 0"
26' - 0"
618 SF UNIT B4 U2
FAU-1 FEC-2 MFR MODEL Fire Extinguisher Cabinet,
U2 REF-1 ACCESSIBLE
SK-1 Surface Mount
586 SF
5' - 7"
10635
4' - 6"
CLOSET CLOSET FEC- MFR MODEL Fire Extinguisher Cabinet,
U2 W15
3' - 6"
W28 W15 K semi-recessed, Class K
W27 W28
W28 (Kitchen)
FS MIFAB FS1734 12 x 12 x 8 DEEP FLOOR
12' - 2"
2 A710
U2 FAU-1 U2 SINK
12' - 2"
U2 OPP.
2' - 0"
UNIT RM. FAU-2 FAU-1 SK-1 GB-1 BOBRICK 580616 18" Vertical Grab Bar Revision Schedule
RNG-1 SK-2 W18 GB-3
WC-1 5 KITCHEN 17 TB-1 GB-2 BOBRICK 580616 24" Grab Bar
NAME NO. W28
LAV-1 W27 FAU-2 # DESCRIPTION DATE
GB-2 13 WA-1 GB-4 GB-3 BOBRICK 580616 36" Grab Bar
UNIT B2 318 KITCHEN W15
LAV-1 GB-4 BOBRICK 580616 42" Grab Bar
7' - 4"
4' - 9"
14 A704 16
9' - 0"
W28 U3 Lavatory
BATH W28
9' - 2"
UNIT B2 329 TB-1 REF-1 TB-1 BATH 19
W16 10 A704 12 W28 CLOSET DR-1 LAV-2
UNIT B2 330 MW-1
15 LAV-3
UNIT B2 333 TP-2 U2 KITCHEN
U1 W14 LIN-1 ClosetMaid ExpressShelf Linen Pantry
11
3' - 9 3/4"
CLOSET
UNIT B2 334 WD-1 SH-3 Shelving
WD-1 SH-3 W27
2' - 3"
UNIT B2 415 U6 REF-1 W18 LIN-2 ClosetMaid ExpressShelf Linen Pantry
SH-2
4' - 5"
3' - 6 1/2"
UNIT PLANS
11' - 7" 11' - 11 1/2"
UNIT B2 433 GB-2 WC-1 PER SHWR MFR UNIT B3 305 PTD-1 BOBRICK B-4262 Paper Towel Dispenser
W26a
UNIT B2 434 2 3/4" 5' - 8" 9' - 0" 6' - 1" 3' - 6" 2 3/4" UNIT B3 403 24' - 0" UNIT RM. 27' - 3" PTW- BOBRICK B-38032 Semi-Recessed Combination
UNIT B2 518 UNIT B3 404 NAME NO. 1 Towel and Waste Unit
UNIT B2 519 24' - 8 1/2" UNIT B3 405 UNIT B4 215 REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
refrigerator
UNIT B2 522 UNIT B3 505 UNIT B4 216
7 REF-2 MFR MODEL Side by Side Refrigerator
18 2
REF-3 U-LINE ADA24RGL Under Counter refrigerator,
32" height
1 UNIT B2 2 UNIT B3 3 UNIT B4 RH-1 MFR MODEL 30" range hood
A303 1/4" = 1'-0" A303 1/4" = 1'-0" A303 1/4" = 1'-0"
RK-1 MFR MODEL Robe Hook
RNG- MFR MODEL 30" residential slide-in range
1
RNG- MFR MODEL 30" residential drop-in range
2
SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
30' - 6" & FIRE Horizontal Curtain
15' - 2" 2' - 6 5/8" 12' - 9 3/8" 27' - 11" SCD- BOBRICK B-301 Recessed Seat Cover
1 Dispenser
13' - 10 1/4" 2' - 8 3/4" 11' - 1" 3" 24' - 3"
SD-1 Bobrick B-2111 ClassicSeries®
3" 8' - 11 5/8" 3' - 0 3/8" 12' - 0"
1' - 0"
SH-1 BEST BATH LES24038A7 1-Piece 36x36 Fiberglass
5FTT Shower Enclosure w/ Trench
3' - 5 5/8"
3' - 0 1/4"
3' - 0 1/4"
W28 SH-2 BEST BATH 4LBS24836F 4-Piece 36x48 Fiberglass
W18
B75FTB Shower Enclosure w/ Trench
W18 Drain, Beveled Threshold
CENTER
2' - 3" SH-3 BEST BATH 5LES26337A 5-Piece 60x36 Fiberglass
1FTB Shower Enclosure w/ Trench
W15 Drain, Beveled Threshold
15' - 5 1/4"
9' - 8"
W18
12' - 8 1/4"
W15
SK-1 MFR MODEL Undermount 17x22 S.S.
LIVING ROOM BEDROOM
13' - 1 1/2"
LIVING ROOM BEDROOM Single Bowl Sink
13' - 9 1/2"
SK-2 MFR MODEL Undermount 17x22 S.S.
Single Bowl Sink, roll-under
BEDROOM depth
SK-3 MFR MODEL Drop-in 33x22 S.S. Double
LIVING ROOM Bowl Sink
SK-4 MFR MODEL Drop-in 17x19 S.S. Single
UNIT B10 6' - 7" 2' - 5" 2' - 1" Bowl Bar Sink
U2
ANSI TYPE ’B’ W15 SK-5 MFR MODEL Activity room Sink, TBD
W28
UNIT B5
29' - 8 1/2"
1' - 11 1/2"
W15
3' - 2" ACCESSIBLE U2 SK-7 AMERICAN 9504.999 'CLINIC SERVICE SINK'
1' - 6"
1' - 0"
2' - 5"
W28 SK-1 W15
U3 645 SF SN-1 BOBRICK B-254 Surface Mounted Sanitary
30' - 0"
30' - 0"
4' - 0 3/4"
6' - 7 1/2"
U2 SST-1 BEST BATH - ADA SHOWER SEAT
W28 CLOSET
U2 TB-1 MFR MODEL 24" Towel Bar
2' - 2 1/4" 5' - 5" 2' - 7" 14
3' - 6"
CLOSET TP-1 BOBRICK B-27313 Surface Mounted Toilet
3' - 2 1/2"
SK-2 FAU-1 W19 W15 W15 W15
Tissue Cabinet
4' - 3" 4' - 0"
FAU-1 U2 A710 W15 TP-2 MFR Toilet Paper Holder
6 A710 7 PER SHWR MFR
UNDER
KITCHEN
SPACE
WORK
TB-1 MW-1
ROLL
14' - 3 1/4"
W27 SH-3
6' - 2"
15 REF-1 urinal.
KITCHEN U6 W15 WA-1 MFR MODEL residential top load washing
RNG-2 WC-1
2' - 1"
1 W18 5 machine
KITCHEN
9' - 9"
10' - 9"
RNG-1
10' - 3"
MFR Washer/Extractor
W18
CLOSET
U2 W15
U6 W28 WC-1 MFR MODEL 17" elongated bowl toilet
3' - 7"
3 2 A706 4 BATH 7
TP-2 (SIM)
BATH WD-1 WHIRLPOO WETLV27HW 27" Long Vent Laundry
U1 3 SH-2 L Center JOB NO.:
CLOSET
WD-1
3' - 6 1/2"
GB-2 U6 WO-1 MFR MODEL Wall Oven 21802.1
FAU-2 LAV-2 REF-1
GB-3 WC-2 W15
PLOT DATE
U1 U1
10 3/4" 1/22/2021 1:07:22 PM
8' - 0 3/4" 2' - 9" 11" 11' - 3 3/4" 6' - 6 3/4" FAU-2 LAV-1 WC-1 PER SHWR
W13a W13a
3" MFR DATE: 01/22/21
4' - 8 1/4" 11' - 1" 3' - 2 1/4" 5' - 4 1/2" 7' - 10 3/4"
3"
4' - 6 3/4" 7' - 8 1/4" 2' - 4 1/2" 9' - 4 1/2" 6 1/4" SCALE: 1/4" = 1’−0"
DRAWN: Author
UNIT RM.
NAME NO. UNIT RM. UNIT RM. CHCKD: Checker
4
A303
UNIT B5hc
1/4" = 1'-0"
5
A303
UNIT B10
1/4" = 1'-0"
6
A303
UNIT B11
1/4" = 1'-0"
A A303
t: 425-453-0606
www.wattenbarger.com
FIXTURES, APPLIANCES & ACCESSORIES
32' - 9"
MA BASIS OF DESIGN
16' - 7 1/4" 15' - 4 3/4"
RK MFR MODEL DESCRIPTION
BELLEVUE, WA 98004
EW-1 GUARDIAN G1806 Eyewash, Deck Mounted, 90º
11' - 9 3/4"
UNIT B6 423
W28 Swivel
UNIT B6 523 U3
12' - 9"
5' - 9 1/2"
CLOSET U2 FAU-1 MFR MODEL Pull Out Kitchen Faucet
3 LIVING ROOM
CLOSET FAU-2 MFR MODEL Two Handle Centerset
W28 W28 Lavatory Faucet
W28
14' - 6 1/2"
FAU-3 MFR MODEL Gooseneck wetbar faucet,
W28 W28
UNIT B6 ANSI A117.1 / ADA
16' - 4 1/2"
ANSI TYPE ’B’ BEDROOM #1 compliant faucet handle
W26
616 SF 10' - 8" LIVING ROOM FAU-4 MFR MODEL Faucet
WC-1 FAU-2 FAU-5 MFR MODEL pulldown kitchen faucet,
UNIT RM. W28 W27
GB-2 LAV-1 ANSI A117.1 / ADA
25' - 0"
NAME NO. 4' - 2" 4' - 5 3/4" 3' - 8" 9 compliant faucet handle
REGISTERED
STATE OF WASHINGTON
ARCHITECT
6' - 0"
UNIT B7 324 FAU-6 MFR MODEL Gooseneck Utility Faucet
TRAVIS McDANOLD
U2 10' - 6"
UNIT B7 424 5 FAU-7 MFR MODEL Wall mount Mop Sink Faucet
BAR BATH 10 A706 12
UNIT B7 524 W26 TB-1 U2 FEC-1 MFR MODEL Fire Extinguisher Cabinet,
W27 TP-2 W28
4' - 1"
W28 UNIT C1
3 U4 BATH #1 semi-recessed
6 A705 8 TB-1 ANSI TYPE ’B’ W28
29' - 2 1/2"
TP-2 FEC-2 MFR MODEL Fire Extinguisher Cabinet,
11
LAV-1 929 SF
33' - 1"
FAU-2 U2 Surface Mount
27' - 0 1/2"
W26
10635
7 FEC- MFR MODEL Fire Extinguisher Cabinet,
W26
11' - 9 3/4"
SH-2 GB-2 K semi-recessed, Class K
3' - 2"
W28 W30 SH-2
TB-1 WC-1 (Kitchen)
REF-1 W30 FS MIFAB FS1734 12 x 12 x 8 DEEP FLOOR
9 SINK
UNIT RM. U4
3' - 8"
BATH U2 U2
W26 WD-1 GB-1 BOBRICK 580616 18" Vertical Grab Bar
NAME NO. W26 BEDROOM
Revision Schedule
2' - 9"
W27 LAV-1 MFR MODEL 20 inch x 17 inch Oval
RNG-1 LAV-1
TP-2 KITCHEN W28 Lavatory
W28
GB-2 FAU-2 U2 WC-1 U3 LAV-2
W28
10' - 9"
A710 8 17 A710
UNIT RM. BEDROOM #2 LAV-3
W28 NAME NO. LIN-1 ClosetMaid ExpressShelf Linen Pantry
TB-1 RNG-1 18 Shelving
CLOSET
SK-1 UNIT C1 306 TP-2
LIN-2 ClosetMaid ExpressShelf Linen Pantry
6' - 5"
UNIT C1 307 SK-1
UNIT RM. CLOSET Shelving
SK-1 UNIT C1 406 U7
W28 GB-2 MW-1 PANASONI NN-CD87KS Microwave Oven +
NAME NO. UNIT C1 407 SH-2 W28 C NN-TK81KCS Trim Kit
8' - 2 1/2"
UNIT B9 326 KITCHEN UNIT C1 506 W30 MW-2 countertop microwave oven
UNIT B9 426 9 W28 UNIT C1 507
W28 CLOSET MW-3 MFR MODEL Microwave Oven
UNIT PLANS
2 U3 RNG-1 6 U1
3' - 11"
11' - 8 1/2" 2' - 5 1/2" PER SHWR MFR 7' - 11 1/2" 5' - 7" PTD-1 BOBRICK B-4262 Paper Towel Dispenser
10 A710 U4 WD-1 PTW- BOBRICK B-38032 Semi-Recessed Combination
34' - 11 1/2" 1 Towel and Waste Unit
U1 REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
REF-1 refrigerator
20' - 3"
REF-2 MFR MODEL Side by Side Refrigerator
W26a UNIT B7 7' - 0" REF-3 U-LINE ADA24RGL Under Counter refrigerator,
ANSI TYPE ’B’ 32" height
580 SF W28 RH-1 MFR MODEL 30" range hood
U1 W28
RK-1 MFR MODEL Robe Hook
RNG- MFR MODEL 30" residential slide-in range
W28 2 UNIT C1 1
10' - 11 3/4" A304 1/4" = 1'-0" RNG- MFR MODEL 30" residential drop-in range
2
U1 U1 U3 SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
CLOSET & FIRE Horizontal Curtain
W26 W28 33' - 3 1/2" SCD- BOBRICK B-301 Recessed Seat Cover
11' - 6" 12' - 0 1/2" 1 Dispenser
W26
14' - 6 1/2" SD-1 Bobrick B-2111 ClassicSeries®
49' - 11 1/2"
1/4" 4' - 3 1/4" 7' - 9" 2' - 7 1/4" Drain, Beveled Threshold
CENTER
SK-1 W28 W28 SH-3 BEST BATH 5LES26337A 5-Piece 60x36 Fiberglass
BEDROOM #1 LIVING ROOM
1FTB Shower Enclosure w/ Trench
12' - 10"
UNIT B8 Drain, Beveled Threshold
KITCHEN
12' - 7"
WC-1 ANSI TYPE ’B’ LIVING ROOM SK-1 MFR MODEL Undermount 17x22 S.S.
W28 SH-2 Single Bowl Sink
7' - 4 1/2"
624 SF
16' - 8 1/2"
CLOSET WD-1 W28 12 A710
SK-2 MFR MODEL Undermount 17x22 S.S.
16 W28 Single Bowl Sink, roll-under
RNG-1
SK-1 13 depth
LAV-1
17 A705 BATH KITCHEN SK-3 MFR MODEL Drop-in 33x22 S.S. Double
FAU-2 RNG-1
UNIT C2 Bowl Sink
U13
CLOSET
GB-2 U2 W28 U8
4' - 9"
7' - 5 1/2"
CLOSET
U2 W28
U3 W28 W30 WC-1 TP-2 U10 SN-1 BOBRICK B-254 Surface Mounted Sanitary
CLOSET W28 SK-1
13 Napkin Disposal
BATH
W28 W27 KITCHEN SST-1 BEST BATH - ADA SHOWER SEAT
UNIT B9
36' - 7"
FAU-2 W30 TB-1 MFR MODEL 24" Towel Bar
ANSI TYPE ’B’ 14 A705 W28 19 A710 REF-1
W28 TP-1 BOBRICK B-27313 Surface Mounted Toilet
642 SF LAV-1 TB-1
W28 Tissue Cabinet
6' - 8" 15 U3
RNG-1 TP-2 MFR Toilet Paper Holder
15' - 10 1/2"
BEDROOM
UR-1 SLOAN SU-7009-A Complete Vitreous China top
U6 W28 W28 spud high efficiency small
LIN.
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
12' - 8 7/8"
8' - 6"
14' - 6"
U6 WA-2 MFR MODEL Commercial top load washing
LAV-1
W28 W28 machine
BATH #1
WA-3 UNIMAC As Specified Commercial
W28 W28
W28 Washer/Extractor
SH-2
W28 WC-1 MFR MODEL 17" elongated bowl toilet
7' - 6"
11' - 4" 13' - 2" 18' - 9 1/2"
NAME NO.
W27
4' - 6 3/4"
UNIT C2 337 BATH #2 DATE: 01/22/21
UNIT C2 437 SCALE: 1/4" = 1’−0"
2 WC-1 SH-2
DRAWN: Author
CHCKD: Checker
9' - 5 207/256"
BLDG. SHEET NO.:
GB-2 TP-2 TB-1
3
A304
UNIT B6, B7, B8, B9
1/4" = 1'-0"
4
A304
UNIT C2
1/4" = 1'-0"
A A304
t: 425-453-0606
www.wattenbarger.com
36' - 6 1/2"
36' - 1 1/2"
FIXTURES, APPLIANCES & ACCESSORIES
11' - 2 3/16" 2' - 5 1/8" 10' - 3 11/16" 5' - 3 1/2" 6' - 0"
11' - 3 5/16" MA BASIS OF DESIGN
RK MFR MODEL DESCRIPTION
BELLEVUE, WA 98004
EW-1 GUARDIAN G1806 Eyewash, Deck Mounted, 90º
LIVING ROOM Swivel
16' - 1 1/2"
13' - 0"
FAU-2 MFR MODEL Two Handle Centerset
W30
BEDROOM #1 Lavatory Faucet
W28 LIVING ROOM FAU-3 MFR MODEL Gooseneck wetbar faucet,
ANSI A117.1 / ADA
U8 W28 compliant faucet handle
U2 BEDROOM #2 FAU-4 MFR MODEL Faucet
CLOSET FAU-5 MFR MODEL pulldown kitchen faucet,
W28
ANSI A117.1 / ADA
13' - 8 3/8"
UNIT C3 W28
W28 compliant faucet handle
REGISTERED
STATE OF WASHINGTON
ARCHITECT
ACCESSIBLE FAU-6 MFR MODEL Gooseneck Utility Faucet
14' - 5 1/2"
TRAVIS McDANOLD
W28 934 SF BEDROOM #1 FAU-7 MFR MODEL Wall mount Mop Sink Faucet
W28 U2
W28 FEC-1 MFR MODEL Fire Extinguisher Cabinet,
U2 semi-recessed
U13
W28 FEC-2 MFR MODEL Fire Extinguisher Cabinet,
U2 W28 W27 Surface Mount
DR-1 WA-1
29' - 1"
10635
REF-1 FAU-2 U8 FEC- MFR MODEL Fire Extinguisher Cabinet,
13
W27 CLOSET W28 K semi-recessed, Class K
W28 LAV-1 U2 (Kitchen)
9' - 6"
U2
1 14 A706 16 FS MIFAB FS1734 12 x 12 x 8 DEEP FLOOR
W28 SINK
CLOSET
7' - 2 1/2"
988 SF LAV-2
U2 W28 KITCHEN
SK-1 LAV-1 1 RNG-1 LAV-3
TB-1 TP-2 GB-2 WC-1 TB-1 TP-2 GB-4
BATH #1 WD-1 W27 LIN-1 ClosetMaid ExpressShelf Linen Pantry
LAV-1 Shelving
DW-2 W27 A711 2
WC-1 TB-1 FAU-2 LIN-2 ClosetMaid ExpressShelf Linen Pantry
8' - 3"
1' - 6"
W28
MIN.
W28 Shelving
CLOSET BATH #2 MW-1 PANASONI NN-CD87KS Microwave Oven +
UNIT RM.
CLOSET
C NN-TK81KCS Trim Kit
UNIT RM.
NAME NO. U2 MW-2 countertop microwave oven
NAME NO.
UNDER
SPACE
WORK
UNIT PLANS
UNIT C3 336 PTD-1 BOBRICK B-4262 Paper Towel Dispenser
UNIT C4 528
UNIT C3 436 PTW- BOBRICK B-38032 Semi-Recessed Combination
U1 2 U1
2 1 Towel and Waste Unit
7' - 9"
WC-1 GB-2 TP-2 TB-1 REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
5' - 4 1/4" 5' - 9" 9' - 0" 2' - 2" 10' - 8 1/4" refrigerator
REF-2 MFR MODEL Side by Side Refrigerator
REF-3 U-LINE ADA24RGL Under Counter refrigerator,
32" height
RH-1 MFR MODEL 30" range hood
RK-1 MFR MODEL Robe Hook
RNG- MFR MODEL 30" residential slide-in range
1 UNIT C3 2 UNIT C4 1
A305 1/4" = 1'-0" A305 1/4" = 1'-0" RNG- MFR MODEL 30" residential drop-in range
2
SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
& FIRE Horizontal Curtain
43' - 0 3/4" SCD- BOBRICK B-301 Recessed Seat Cover
1 Dispenser
SD-1 Bobrick B-2111 ClassicSeries®
CENTER
SH-3 BEST BATH 5LES26337A 5-Piece 60x36 Fiberglass
U12 W15 1FTB Shower Enclosure w/ Trench
Drain, Beveled Threshold
7' - 4 3/4"
SK-1 MFR MODEL Undermount 17x22 S.S.
REF-1 W15 Single Bowl Sink
CLOSET
4' - 1 5/8"
KITCHEN SK-2 MFR MODEL Undermount 17x22 S.S.
Single Bowl Sink, roll-under
12' - 4 3/8"
12' - 11 3/8"
W28 depth
14' - 8 3/4"
SK-3 MFR MODEL Drop-in 33x22 S.S. Double
3 4
11' - 8 3/16"
18' - 10 3/4"
SK-2 5 BEDROOM #1 W15
RNG-2
SK-5 MFR MODEL Activity room Sink, TBD
SK-6 MFR MODEL Laundry/Utility Sink
W28
W15 SK-7 AMERICAN 9504.999 'CLINIC SERVICE SINK'
DW-2 UNIT C6 STANDARD mounted on floor base
12' - 7" W15 ACCESSIBLE
6' - 9 7/8" SK-8 MFR MODEL 24"x 24" Floor Mop Sink
U2 1029 SF
3' - 0 1/8" SN-1 BOBRICK B-254 Surface Mounted Sanitary
W15 Napkin Disposal
U2 W28
29' - 6 9/16"
U2 SST-1 BEST BATH - ADA SHOWER SEAT
W28 U2
6' - 4 1/2" 5' - 7 3/4" W15 TB-1 MFR MODEL 24" Towel Bar
5' - 11 3/8"
U2
5' - 7 3/4"
U2 TP-1 BOBRICK B-27313 Surface Mounted Toilet
UNIT C5 Tissue Cabinet
ACCESSIBLE U13
TB-1 CLOSET REF-1 TP-2 MFR Toilet Paper Holder
1042 SF ROLL W14
W28 U2 UNDER W27 W28 GB-4 SH-2 UR-1 SLOAN SU-7009-A Complete Vitreous China top
WORK U2 spud high efficiency small
6' - 7"
WA-1 DR-1
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
TP-2 urinal.
BATH #1
ROLL WA-1 MFR MODEL residential top load washing
CLOSET
W28 UNDER
machine
U5 W28 U2
WORK
W15
9' - 7 11/16"
SPACE
BEDROOM #2 SH-2 WA-2 MFR MODEL Commercial top load washing
CLOSET BATH #1 W15
W15 W18 CLOSET KITCHEN machine
14' - 5"
W28 W28
FAU-2 WA-3 UNIMAC As Specified Commercial
W14 Washer/Extractor
WC-2 GB-3 BATH #2 DW-2
W30 W30 LAV-2
CLOSET
9' - 11 3/8"
3
A305
UNIT C5
1/4" = 1'-0"
4
A305
UNIT C6hc
1/4" = 1'-0"
A A305
t: 425-453-0606
www.wattenbarger.com
61' - 5 3/8"
FIXTURES, APPLIANCES & ACCESSORIES
5' - 6 7/8" 11' - 6 7/8" 12' - 1" 14' - 1" 15' - 5 3/4" MA BASIS OF DESIGN
RK MFR MODEL DESCRIPTION
3' - 2 1/8"
DR-2 MFR MODEL Electric Commercial top load
7' - 3"
16' - 5 1/8" DW-2 MFR MODEL 24" dishwasher, 32" height
BELLEVUE, WA 98004
11 3/8" EW-1 GUARDIAN G1806 Eyewash, Deck Mounted, 90º
LIVING ROOM W15 Swivel
11' - 8 3/8"
11' - 0"
BEDROOM #1 BEDROOM #1
U2 FAU-1 MFR MODEL Pull Out Kitchen Faucet
W15
FAU-2 MFR MODEL Two Handle Centerset
LIVING ROOM W15 Lavatory Faucet
17' - 11 13/16"
FAU-3 MFR MODEL Gooseneck wetbar faucet,
W15 ANSI A117.1 / ADA
UNIT C7 compliant faucet handle
LAV-1 U2 ANSI TYPE ’B’ FAU-4 MFR MODEL Faucet
W15 891 SF W15 W14 SH-2 W15 W15 FAU-5 MFR MODEL pulldown kitchen faucet,
ANSI A117.1 / ADA
compliant faucet handle
8' - 8"
REGISTERED
STATE OF WASHINGTON
ARCHITECT
U2 U2 U2 FAU-6 MFR MODEL Gooseneck Utility Faucet
TB-1
TRAVIS McDANOLD
BATH #1 REF-1 KITCHEN FAU-7 MFR MODEL Wall mount Mop Sink Faucet
WD-1 TP-2
FAU-2 BATH #1 FEC-1 MFR MODEL Fire Extinguisher Cabinet,
5' - 11 13/16"
UNIT RM. U4
28' - 7"
SH-2 W15 UNIT C8 SK-1 semi-recessed
NAME NO. WC-1 LAV-1 FAU-2
31' - 9 9/16"
WC-1 W15 ANSI TYPE ’B’ FEC-2 MFR MODEL Fire Extinguisher Cabinet,
8' - 3 5/8"
UNIT C7 252 855 SF CLOSET Surface Mount
10635
1 CLOSET W15 FEC- MFR MODEL Fire Extinguisher Cabinet,
U2 RNG-1 K semi-recessed, Class K
W15 7' - 7 1/2" (Kitchen)
W15
CLOSET
GB-2 TP-2 TB-1 KITCHEN
U6 W15 RNG-1 FS MIFAB FS1734 12 x 12 x 8 DEEP FLOOR
W15
W14 GB-2 SINK
U3
GB-1 BOBRICK 580616 18" Vertical Grab Bar Revision Schedule
U2 W14
W15 U2 GB-2 BOBRICK 580616 24" Grab Bar
BEDROOM #2 SK-1 W15 # DESCRIPTION DATE
GB-3 BOBRICK 580616 36" Grab Bar
W15
GB-4 BOBRICK 580616 42" Grab Bar
11' - 10 3/8"
LAV-1 REF-1 W15
9' - 4 5/16"
WD-1 W15
W15 W15 LAV-1 MFR MODEL 20 inch x 17 inch Oval
BEDROOM #2 Lavatory
FAU-2 U2
U1 LAV-2
13' - 1 5/16"
LAV-3
CLOSET
BATH #2
W15 W13a W13 W13a LIN-1 ClosetMaid ExpressShelf Linen Pantry
W14 W15 W15 Shelving
UNIT RM. LAV-1 SH-2
U8 LIN-2 ClosetMaid ExpressShelf Linen Pantry
NAME NO. SH-2 WC-1 FAU-2
U1 Shelving
W15
UNIT C8 251 MW-1 PANASONI NN-CD87KS Microwave Oven +
W13 BATH #2
1 C NN-TK81KCS Trim Kit
U7 U7
MW-2 countertop microwave oven
11' - 4 3/8" 2' - 0" 9' - 2 3/16" 5' - 9" 9' - 2 3/8" W15 MW-3 MFR MODEL Microwave Oven
W18 WC-1 W14
UNIT PLANS
W15
PTD-1 BOBRICK B-4262 Paper Towel Dispenser
TB-1 TP-2 GB-2 CLOSET CLOSET
29' - 6" PTW- BOBRICK B-38032 Semi-Recessed Combination
1 Towel and Waste Unit
6' - 11 1/8" 2' - 11 5/8" 5' - 2 5/16" 5' - 2 7/16"
REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
GB-2 TP-2 TB-1 22' - 6 9/16" refrigerator
W12
REF-2 MFR MODEL Side by Side Refrigerator
REF-3 U-LINE ADA24RGL Under Counter refrigerator,
32" height
RH-1 MFR MODEL 30" range hood
RK-1 MFR MODEL Robe Hook
RNG- MFR MODEL 30" residential slide-in range
2 UNIT C7, C8 1
A306 1/4" = 1'-0" RNG- MFR MODEL 30" residential drop-in range
47' - 7 3/4" 2
12' - 2 5/16" 10' - 8 7/16" 12' - 8 3/8" 10' - 7 3/4"
SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
& FIRE Horizontal Curtain
18 37' - 5 1/4" SCD- BOBRICK B-301 Recessed Seat Cover
U2 TB-1 12' - 8 3/8" 1 Dispenser
SH-2 15' - 2 3/4" 10' - 2" 11' - 0"
SD-1 Bobrick B-2111 ClassicSeries®
15 A707 17
15' - 4 3/4"
U12 Drain, Beveled Threshold
CENTER
FAU-2 3' - 0" SH-3 BEST BATH 5LES26337A 5-Piece 60x36 Fiberglass
WC-1
3' - 0 1/8"
1FTB Shower Enclosure w/ Trench
W15
W30 Drain, Beveled Threshold
W18 UNIT C9
SK-1 MFR MODEL Undermount 17x22 S.S.
ANSI TYPE ’B’
7' - 8 3/4"
12' - 8 1/2"
13' - 0"
SK-3 MFR MODEL Drop-in 33x22 S.S. Double
W15 TP-2 GB-2 U8 Bowl Sink
LIVING ROOM BEDROOM #2 BEDROOM #1
2' - 1 1/4"
15' - 3 1/2"
CLOSET SK-4 MFR MODEL Drop-in 17x19 S.S. Single
5' - 10 17/32" Bowl Bar Sink
U2 U4 WD-1
SK-5 MFR MODEL Activity room Sink, TBD
6' - 9 3/8"
1' - 6"
CLOSET
9 W28
10' - 9 3/8"
BEDROOM #2 W15 W15 SK-8 MFR MODEL 24"x 24" Floor Mop Sink
3' - 2"
41' - 6 5/8"
RNG-1
W18 UNIT C11 SST-1 BEST BATH - ADA SHOWER SEAT
10' - 10 3/8" 2' - 1 3/8" 11
29' - 6 1/2"
ANSI TYPE ’B’ 4' - 3 1/4" TB-1 MFR MODEL 24" Towel Bar
TB-1 13 W15 U2
W15 REF-1 988 SF TP-1 BOBRICK B-27313 Surface Mounted Toilet
W18 10' - 5 1/2" W28
W15 BATH #2 10' - 8" 4' - 1" W15 Tissue Cabinet
7' - 0 1/2"
13' - 1 7/8"
6' - 6"
6' - 6"
SH-2 W13 CLOSET UR-1 SLOAN SU-7009-A Complete Vitreous China top
3' - 3 1/2"
TB-1 W15 W28 W27 U2 spud high efficiency small
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
W15 urinal.
W14 BATH #2 U2 8' - 6 3/4" U2
SH-2 W28 WA-1 MFR MODEL residential top load washing
UNIT RM. 9 A707 11 BAR machine
TP-2
NAME NO.
CLOSET
GB-2 U2 WA-2 MFR MODEL Commercial top load washing
REF-1
3' - 0"
UNIT C9 243
25' - 6 5/8"
10 U6 SH-2 machine
W15 WD-1
1 U2 WA-3 UNIMAC As Specified Commercial
UNIT C10 WD-1 CLOSET LAV-1 W15 WC-1 GB-2 TP-2
SH-2 Washer/Extractor
ANSI TYPE ’B’ REF-1
WC-1 FAU-2 W30 WC-1 MFR MODEL 17" elongated bowl toilet
12' - 6"
10' - 10 5/16"
9' - 0"
W15 U2 L Center JOB NO.:
W13 RNG-1 15
BATH #1 BATH #1 21802.1
5' - 5 1/4"
A A306
7' - 1 1/4"
3 UNIT C9, C10 4 UNIT C11
A306 1/4" = 1'-0" A306 1/4" = 1'-0"
t: 425-453-0606
www.wattenbarger.com
FIXTURES, APPLIANCES & ACCESSORIES
MA BASIS OF DESIGN
4 RK MFR MODEL DESCRIPTION
BELLEVUE, WA 98004
EW-1 GUARDIAN G1806 Eyewash, Deck Mounted, 90º
W14 3 4 Swivel
2' - 11 7/64"
9' - 11 223/256"
F F SH-3
FAU-1 MFR MODEL Pull Out Kitchen Faucet
FAU-2 MFR MODEL Two Handle Centerset
W18 W14
4' - 11 5/8"
PASSAGE WOMEN A708 6 Lavatory Faucet
102 116 GB-4 GB-1 TP-1 TB-1 FAU-3 MFR MODEL Gooseneck wetbar faucet,
W18 ANSI A117.1 / ADA
W14 116 compliant faucet handle
6' - 1 245/256" FAU-4 MFR MODEL Faucet
FAU-5 MFR MODEL pulldown kitchen faucet,
GB-3 ANSI A117.1 / ADA
A708 compliant faucet handle
REGISTERED
117
STATE OF WASHINGTON
LOUNGE
ARCHITECT
W14 FAU-6 MFR MODEL Gooseneck Utility Faucet
TRAVIS McDANOLD
SCD-1
4' - 10 3/8"
4 5 W15 118 FAU-7 MFR MODEL Wall mount Mop Sink Faucet
5' - 4 1/4"
FEC-1 MFR MODEL Fire Extinguisher Cabinet,
1' WC-1 2
-4 semi-recessed
W14
M 5 FEC-2 MFR MODEL Fire Extinguisher Cabinet,
W14a WC-2 IN /8" Surface Mount
. 1 A708 3
10635
4 FEC- MFR MODEL Fire Extinguisher Cabinet,
K semi-recessed, Class K
NURSE
11' - 0 1/4"
"
56
W14 EMP. (Kitchen)
/2
SD-1 STATION A713 5
49
WC-2 BATH FS MIFAB FS1734 12 x 12 x 8 DEEP FLOOR
121
6
10' - 0 3/8"
SINK
'-
009
10
A708 W1-12
3' - 0 255/256" GB-1 BOBRICK 580616 18" Vertical Grab Bar Revision Schedule
7 A708 MEN
W17 W15 GB-2 BOBRICK 580616 24" Grab Bar
117 9
LAV-1 # DESCRIPTION DATE
GB-3 BOBRICK 580616 36" Grab Bar
5' - 10 1/4"
W14
8 GB-4 BOBRICK 580616 42" Grab Bar
SCD-1 FAU-2
6' - 2"
1' LAV-1 MFR MODEL 20 inch x 17 inch Oval
-6 W14
PTW-1 M W14 W18
IN " Lavatory
. LAV-2
W14 LAV-3
TP-1 119 LIN-1 ClosetMaid ExpressShelf Linen Pantry
SD-1 LAV-1 120A 120B Shelving
W18 GB-1 W18 H W18
H LIN-2 ClosetMaid ExpressShelf Linen Pantry
"
56
Shelving
/2
45
ENLARGED FLOOR
5'
PLANS
5' - 1 1/4" MED RM 1 Towel and Waste Unit
120 REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
refrigerator
CONSULT. REF-2 MFR MODEL Side by Side Refrigerator
119 REF-3 U-LINE ADA24RGL Under Counter refrigerator,
1 A713 2 32" height
RH-1 MFR MODEL 30" range hood
3 W14 RK-1 MFR MODEL Robe Hook
RNG- MFR MODEL 30" residential slide-in range
1
RNG- MFR MODEL 30" residential drop-in range
W13 SK-4 W13 2
SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
& FIRE Horizontal Curtain
1 ENLARGED 1ST FLOOR COMMON BATHROOMS 2 ENLARGED BASEMENT EMPLOYEE BATH SCD- BOBRICK B-301 Recessed Seat Cover
A307 3/8" = 1'-0" A307 3/8" = 1'-0" 1 Dispenser
SD-1 Bobrick B-2111 ClassicSeries®
CENTER
W13
SH-3 BEST BATH 5LES26337A 5-Piece 60x36 Fiberglass
W2-12
G 1FTB Shower Enclosure w/ Trench
Drain, Beveled Threshold
128 SK-1 MFR MODEL Undermount 17x22 S.S.
HALL
Single Bowl Sink
W14
127
W13 W18 SK-2 MFR MODEL Undermount 17x22 S.S.
W18 129
127 W19 W14 Single Bowl Sink, roll-under
W18 CORRIDOR SK-6 depth
122 SK-3 MFR MODEL Drop-in 33x22 S.S. Double
Bowl Sink
STOR. W18
J J SK-4 MFR MODEL Drop-in 17x19 S.S. Single
E 206 E Bowl Bar Sink
W18 SK-5 MFR MODEL Activity room Sink, TBD
SK-6 MFR MODEL Laundry/Utility Sink
W13 W18 W13 W19
W18 W18 SK-7 AMERICAN 9504.999 'CLINIC SERVICE SINK'
MAIL W1-12 STANDARD mounted on floor base
209 130 S. LIN.
W18 15 SK-8 MFR MODEL 24"x 24" Floor Mop Sink
RECEPTION RES. 129 W17 SN-1 BOBRICK B-254 Surface Mounted Sanitary
W13
205 W18 W18 LAUNDRY Napkin Disposal
W14 14 A712
W14 10
130 SST-1 BEST BATH - ADA SHOWER SEAT
W14 TB-1 MFR MODEL 24" Towel Bar
FEC-1 W18
13 TP-1 BOBRICK B-27313 Surface Mounted Toilet
9 A714 8
Tissue Cabinet
11 130a TP-2 MFR Toilet Paper Holder
W13 UR-1 SLOAN SU-7009-A Complete Vitreous China top
W13 spud high efficiency small
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
urinal.
W18 WA-1 MFR MODEL residential top load washing
W14 4' - 0" machine
WA-2 MFR MODEL Commercial top load washing
machine
WA-3 UNIMAC As Specified Commercial
W18 W18 WA-2 WA-2 DR-2 DR-2 Washer/Extractor
WC-1 MFR MODEL 17" elongated bowl toilet
A A307
A702.
W14
6. FLOOR FINISH TO CONTINUE UNDER ALL
4 ENLARGED 2ND FLOOR RECEPTION 5 ENLARGED 2ND FLOOR MAIL ROOM 6 ENLARGED 1ST FLOOR MC NURSE AREA REMOVEABLE CASEWORK AND OPEN BELOW WORK
A307 3/8" = 1'-0" A307 3/8" = 1'-0" A307 1/4" = 1'-0" SURFACES AT TYPE 'A' UNITS.
t: 425-453-0606
www.wattenbarger.com
3 FIXTURES, APPLIANCES & ACCESSORIES
MA BASIS OF DESIGN
RK MFR MODEL DESCRIPTION
"
11
DW-2 MFR MODEL 24" dishwasher, 32" height
BELLEVUE, WA 98004
EW-1 GUARDIAN G1806 Eyewash, Deck Mounted, 90º
8"
A714
8' - 4" Swivel
W14 FAU-1 MFR MODEL Pull Out Kitchen Faucet
"
5' - 11 121/128"
8
1/
12 FAU-2 MFR MODEL Two Handle Centerset
-1
W14 MECH.
5' - 2 7/8"
Lavatory Faucet
5'
W14 TP-1 GB-1 GB-4 208
222 FAU-3 MFR MODEL Gooseneck wetbar faucet,
5' - 3 1/4"
W19 W14
SHOWER ANSI A117.1 / ADA
211 219 compliant faucet handle
WC-2 FAU-4 MFR MODEL Faucet
FAU-5 MFR MODEL pulldown kitchen faucet,
H ANSI A117.1 / ADA
1' - 6"
MIN.
REGISTERED
STATE OF WASHINGTON
ARCHITECT
FAU-6 MFR MODEL Gooseneck Utility Faucet
TRAVIS McDANOLD
W14
W14 FAU-7 MFR MODEL Wall mount Mop Sink Faucet
SCD-1 W14 W14
FEC-1 MFR MODEL Fire Extinguisher Cabinet,
16' - 2 3/4"
5' - 11 1/2"
W14
4' - 5 1/8"
GB-3 13 A708 15 GB-1 GB-4 semi-recessed
11 W14
6' - 10"
6' - 10"
SN-1 FAU-2 FEC-2 MFR MODEL Fire Extinguisher Cabinet,
PTW-1
GB-4 SCD-1 Surface Mount
5' - 1 1/4"
14
10635
10 A708 12 MEN LAV-1 FEC- MFR MODEL Fire Extinguisher Cabinet,
6' - 2 3/4"
LAV-1 K semi-recessed, Class K
GB-1 211
1' - 6"
MIN.
(Kitchen)
FAU-2 TP-1 W14 TP-1
FS MIFAB FS1734 12 x 12 x 8 DEEP FLOOR
W14 WOMEN EQP. SINK
1
210 WC-2
W13 221 W14 WC-2 GB-1 BOBRICK 580616 18" Vertical Grab Bar
W18
2' - 6"
Revision Schedule
W14 W14 SD-1 GB-2 BOBRICK 580616 24" Grab Bar
2 A709 3 GB-3 # DESCRIPTION DATE
GB-3 BOBRICK 580616 36" Grab Bar
6' - 11"
10 1/2"
3' - 7 1/4"
TOILET LAV-2
8' - 0"
1' - 6" SCD-1 GB-3 W14 FAU-2
W14
3
220 LAV-3
MIN. LAV-1 LIN-1 ClosetMaid ExpressShelf Linen Pantry
5' - 6"
Shelving
JAN. A714 6 LIN-2 ClosetMaid ExpressShelf Linen Pantry
10 1/2" Shelving
213
7' - 5 1/2" W13 MW-1 PANASONI NN-CD87KS Microwave Oven +
SD-1 PTW-1 C NN-TK81KCS Trim Kit
ENLARGED FLOOR
8' - 4" 213 W13
MW-2 countertop microwave oven
W14
MW-3 MFR MODEL Microwave Oven
2' - 0" 6' - 9" PTD-1 BOBRICK B-4262 Paper Towel Dispenser
8' - 9" PTW- BOBRICK B-38032 Semi-Recessed Combination
PLANS
1 Towel and Waste Unit
REF-1 FRIGIDAIRE FFTR1821TS ADA Compliant top-freezer
5' - 2" 4' - 7"
refrigerator
REF-2 MFR MODEL Side by Side Refrigerator
REF-3 U-LINE ADA24RGL Under Counter refrigerator,
32" height
RH-1 MFR MODEL 30" range hood
RK-1 MFR MODEL Robe Hook
RNG- MFR MODEL 30" residential slide-in range
1
RNG- MFR MODEL 30" residential drop-in range
1 ENLARGED 2ND FLOOR WOMEN'S ROOM 2 ENLARGED 2ND FLOOR MEN'S ROOM 3 ENLARGED 2ND FLOOR POOL BATHROOM-SHOWER 2
A308 3/8" = 1'-0" A308 3/8" = 1'-0" A308 3/8" = 1'-0" SC2 US SMOKE SD240GS 3 HR Horizontal Fire Smoke
& FIRE Horizontal Curtain
SCD- BOBRICK B-301 Recessed Seat Cover
1 Dispenser
SD-1 Bobrick B-2111 ClassicSeries®
CENTER
SH-3 BEST BATH 5LES26337A 5-Piece 60x36 Fiberglass
12' - 3 1/2"
1FTB Shower Enclosure w/ Trench
9' - 9 1/2" Drain, Beveled Threshold
3' - 2 3/8" W29 SK-1 MFR MODEL Undermount 17x22 S.S.
PTW-1 SD-1
Single Bowl Sink
SK-2 MFR MODEL Undermount 17x22 S.S.
Single Bowl Sink, roll-under
12' - 5 1/2" depth
SK-3 MFR MODEL Drop-in 33x22 S.S. Double
E E 5' - 6" 6' - 6"
Bowl Sink
W27 PTW-1 SD-1 SK-4 MFR MODEL Drop-in 17x19 S.S. Single
W27 Bowl Bar Sink
MEN LAV-3
SK-5 MFR MODEL Activity room Sink, TBD
503
SK-6 MFR MODEL Laundry/Utility Sink
SK-7 AMERICAN 9504.999 'CLINIC SERVICE SINK'
6' - 10"
W27 W27
W26 STANDARD mounted on floor base
5
W26 SK-8 MFR MODEL 24"x 24" Floor Mop Sink
LAV-3
9' - 11 1/2"
SN-1 BOBRICK B-254 Surface Mounted Sanitary
4 A709 6 9' - 3 1/2" Napkin Disposal
SCD-1 GB-3 LAV-3
W27 W27 SST-1 BEST BATH - ADA SHOWER SEAT
1' - 6" TP-1
10 LAV-3 TB-1 MFR MODEL 24" Towel Bar
13' - 1 1/2"
MIN. 503 GB-4 GB-1 TP-1
4' - 0" TP-1 BOBRICK B-27313 Surface Mounted Toilet
Tissue Cabinet
11 A709 12 TP-2 MFR Toilet Paper Holder
UR-1 SLOAN SU-7009-A Complete Vitreous China top
WC-2 spud high efficiency small
UR-1
C:\Revit\21802-BP-BLDG A-CENTRAL_travism@wattenbarger.com.rvt
1' - 6"
WOMEN
MIN.
WC-2 urinal.
GB-4 TP-1 510 WA-1 MFR MODEL residential top load washing
TP-1 G WC-2 WA-2 MFR MODEL
machine
Commercial top load washing
5' - 10"
6' - 6"
8 machine
GB-1 5' - 8" A709 15 W26
WC-2 GB-3
13 WA-3 UNIMAC As Specified Commercial
7 A709 A709 16 Washer/Extractor
3' - 2"
5
A308
ENLARGED 5TH FLOOR MEN'S ROOM
3/8" = 1'-0"
6
A308
ENLARGED 5TH FLOOR WOMEN'S ROOM - PUB
3/8" = 1'-0"
REMOVEABLE CASEWORK AND OPEN BELOW WORK
SURFACES AT TYPE 'A' UNITS. A A308
t: 425-453-0606
www.wattenbarger.com
LIGHT FIXTURE SCHEDULE
BASIS OF DESIGN
1 2 3 4 5 6 7 MARK DESCRIPTION MFR. MODEL
BELLEVUE, WA 98004
F10 Extr. LED wall sconce Cooper Industries, Model
Inc.
B B F11
F12
Ceiling Fan
2x4 Troffer Direct/Indirect
F13 LED Wall Sconce
F14 Drop Pendant
SOILED
F16 Vanity Light
LIN. G1 4' Lensed LED Striplight Cooper Lighting SNLED