 Software Architecture Overview
 Fundamentals
 Mimics
 Device Windows
 Events and Alarms
 System Notes
 Trending
 Macros
 Server Software
 CMS
 ULPC
 Software Upgrades
 Reference Material

135405(1) SED Proprietary 3


135405(1) SED Proprietary 4
 Software consists of:
◦ Server software
 Runs as a Windows Service.
 Polls equipment for status, performs measurement requests,
provides remote interfaces to INMS and SCC
 Single server computer, setup to allow for redundancy
 MySQL database is used for persistent data storage
◦ GUI client software
 Runs on the server computers or on a separate client PC

135405(1) SED Proprietary 5


135405(1) SED Proprietary 6
Main Menu
Tool bar
Server
Management

Device
Browser

Mimic
Browser

Current
Alarms

Recent
Events

Status Bar

135405(1) SED Proprietary 7


 Device and mimic browsers have the following features:
◦ Have a selection bar across the top
◦ Allow multiple tabs to be displayed
◦ Display the summary health on each tab
 The selection bar allows you to:
◦ Select the Server
◦ For the selected Server, select a device (for device browsers)
or a mimic (for mimic browsers)
◦ Enter a filter that reduces the number of choices available
◦ Open a tab for the selected mimic or device by clicking on
◦ Close the currently selected tab by clicking on

135405(1) SED Proprietary 8


 You must log in to access most capabilities
 Capabilities are made available based on your role
 Available Roles:
◦ Operator
◦ Administrator
 Events are generated when you log in and out
 Who is currently logged in is shown on the status bar

135405(1) SED Proprietary 9


135405(1) SED Proprietary 10
Switch
Overall health of all positions
devices shown

Highlights online
signal paths

Click to open Key device


device window Device overall
health attribute values
135405(1) SED Proprietary 11
135405(1) SED Proprietary 12
Close Stretch
Overall health of
device Open Resize

Standard
attributes

Standard tabs

Summary health of
attributes in tab

135405(1) SED Proprietary 13


 Overall Health
◦ For an entity, the worst health of any of its attributes
 Comm Status – Failed / Established
◦ When communication status is failed, the health for all other
attributes for a device changes to unknown. The last known
value is displayed
 Summary Alarm – Fault / No fault
 Control Mode – Local / Remote
◦ When in local, most devices can only be controlled from their
front panel
 Maintenance Mode – In / Out
◦ When in maintenance, the health of all other attributes is not
computed and no communication with the device
 Test Mode – In / Out
◦ When in test, the health of all other attributes is not computed
135405(1) SED Proprietary 14
 No comms to device

 No connection to server

135405(1) SED Proprietary 15


Greyed out – not logged in or not authorized

In sync Last Commanded


Current

135405(1) SED Proprietary 16


Edit value. New value is colored yellow to show it
has been changed

Press Execute Undo edit. Not undo


previous commands

Command in progress

135405(1) SED Proprietary 17


Commanded unsuccessful. Out of sync

This could happen if a device is in local control mode for example,


and does not process the command from the M&C system.

135405(1) SED Proprietary 18


Commanded successful. In sync

Resulting events

135405(1) SED Proprietary 19


Delete Row Edit Row Table sorted on
this column
Add Row

Edit the values

Click execute

135405(1) SED Proprietary 20


 Used to compute health of an attribute
 Current value of the attribute is checked against all the
criteria
 Violation of a criterion results in a change in the attribute
health
 Device Type level and instance level

135405(1) SED Proprietary 21


If not 0, ignore violation until this
Resulting health if many milliseconds have gone by
criterion is violated

You can disable a criterion

Criterion is violated if this


expression is true

Use other attributes to


indicate cause

135405(1) SED Proprietary 22


 There can be 0 or more criteria
 Attribute’s health is none if there are no criteria
 Attribute’s health is good if none of the criteria are violated
 If multiple criteria are violated, the attribute’s health is the
worst severity

135405(1) SED Proprietary 23


 To view/edit the health criteria for an attribute:
◦ Select the attribute

 In the drop down list

 Or using the
Change to attribute selection mode

Click on the attribute


135405(1) SED Proprietary 24
◦ View the health criteria in the health criteria tab

◦ To edit double click a criterion or select and click open

135405(1) SED Proprietary 25


◦ Edit the criteria Set how long the criteria has to be
violated before the health changes

Change the resulting health

Enable or disable the criterion

This string will be written in


the associated event

Change the expression


used to check for violation

Edit cause relationships

135405(1) SED Proprietary 26


◦ Fault comparison
 Involves the current value of the attribute
 “this” means the value of the attribute. You can also use the attribute Id,
e.g. CommStatus
 Numeric comparison
 this <= -5.0
 Comparison with a fixed number of values, e.g. Communication Status
 this == "CS_CONN_OPENED“
 Compare with
 == equals
 != not equals
 < less than, <= less than or equal to
 > greater than, >= greater than or equal to
 The comparison can have && (and) and || (or)
 (this <= -5.0) || (this >= 50)

135405(1) SED Proprietary 27


◦ Fault comparison editor

135405(1) SED Proprietary 28


◦ Edit the value in the editable text box

Invalid value highlighted in red

Tool tip explains error

135405(1) SED Proprietary 29


◦ To change a fixed value, you can use the “value” part of the
“Create Expression for Comparison”
Starting expression

Select the new value

Add to the comparison

Fix the comparison


135405(1) SED Proprietary 30
◦ Cause
 A change in health in one attribute can be caused by the change in
health in another
 If the M&C can’t communicate with an LNA controller, the comm
status of the LNAs will also be failed

135405(1) SED Proprietary 31


 The Command Status information is displayed in the
Additional Information section on the Command Status tab
 Displays status messages with the most recent message at
the top
 When the user executes a command, the software displays
a message indicating whether the command completed
successfully or failed

135405(1) SED Proprietary 32


 The Attribute Information is displayed in the Attribute Info
tab
 Select an attribute using the drop down list or the pointer
( )
Health Status Reason for health status
Value
Name
Last update time

135405(1) SED Proprietary 33


 The System Notes for the selected device are displayed in
the System Notes tab
 Displays information on device being monitored and
controlled
 Describe a problem with a device or class of devices

135405(1) SED Proprietary 34


 The Properties tab lists the device configuration
parameters such as IP address

135405(1) SED Proprietary 35


 The I/O Monitor tab displays the exchange with the device
 This tab is not available for indirect devices
 \x2f means the unprintable character with hex value 2f was
sent or received

135405(1) SED Proprietary 36


135405(1) SED Proprietary 37
 An event is raised to indicate that something of note has
occurred, e.g. attribute health change
 Event contents
◦ Severity
 A "Normal" information event
 A "Warning" information event
 An event that clears a previous fault or warning event
 An event indicating a Warning condition
 An event indicating a Minor Failure condition
 An event indicating a Major Failure condition
 An event indicating a Critical Failure condition
◦ Date and time the event occurred
◦ Source that identifies the origin, e.g. “BUC 1"
◦ Text describing the event

135405(1) SED Proprietary 38


 Two types of Event Windows:
◦ Recent Events
 Displays new events as they occur
 From the main menu, choose View | Current Events
◦ Historical Events
 Allows you to query the database for old event data
 From the menu on the Recent Events window, Choose View |
Historical Events

135405(1) SED Proprietary 39


 Both types of event windows can be filtered
 Can sort on any column. Filters are above the column titles
 Double clicking on an event will open the event detail
window

135405(1) SED Proprietary 40


135405(1) SED Proprietary 41
 An alarm is a condition triggered by an event of severity
greater than “information”
 Subsequent events from the same source may upgrade or
downgrade the severity of the alarm, but are considered to
be part of the same alarm until all three of the following
have occurred:
◦ A clear event is received
◦ The alarm is acknowledged by an operator
◦ The user has removed the alarm from view
 The user may only remove an alarm from view when the
alarm has been cleared and acknowledged

135405(1) SED Proprietary 42


 Alarm contents:
◦ Alarm acknowledgement state:
 Unacknowledged
 Acknowledged
◦ Current severity of the alarm (indicated by the icon)
◦ Maximum severity of the alarm (indicated by the icon)
◦ An indication of whether this alarm caused other alarms or
was caused by another alarm
◦ Date and time of the original triggering event
◦ Date and time that the last event that changed the severity
◦ Source of the event that triggered the alarm
◦ Text description from the most recent event associated with
the alarm

135405(1) SED Proprietary 43


 Two types of Alarm Windows:
◦ Current Alarms
 Displays alarms that have not been removed
 From the main menu, choose View | CurrentAlarms
◦ Historical Alarms
 Allows you to query the database for alarms that have been
removed from the current alarm window
 From the menu on the Current Alarms window, Choose View |
Historical Alarms

135405(1) SED Proprietary 44


Total of each severity Filters
Filters

Sound on

Acked

Unacked

Cleared

In minor failure

Remove alarm from Force current severity to


window if acked and cleared – used rarely
cleared Open alarm details Open device window
window
135405(1) SED Proprietary 45
 Double click on an alarm to open the alarm detail window
◦ Same info as shown in alarm window
◦ Also shows who acked the alarm and when
◦ Also shows all the associated events

135405(1) SED Proprietary 46


135405(1) SED Proprietary 47
 System Notes tab on each device window allows a user to
enter a note to be viewed by other users
 System Notes is also available from the main menu View >
System Notes or the toolbar

135405(1) SED Proprietary 48


 Click the button to add a new system note or select
a cell and click the button to modify an existing
System Note

135405(1) SED Proprietary 49


 In the search section, select field to compare, type of
comparison to perform and value to compare to. Click the
button to perform the search

 The table displays all system notes that match the search
criteria

135405(1) SED Proprietary 50


135405(1) SED Proprietary 51
 Attributes visible in the device windows are logged to the
database on change
 View the historical data through the Trending Window
(under View | Trending)

135405(1) SED Proprietary 52


 First select the devices and their attributes

Filter shown devices


if desired

Click to select devices.


Check Select all of same
type to multiselect
devices of the same type

Click to select attributes.


Shift click or Ctrl click to
multiselect

ClickAdd
135405(1) SED Proprietary 53
 Set the time period

Set an absolute time or


relative
135405(1) SED Proprietary 54
 Query for the data

Click Query
135405(1) SED Proprietary 55
 View the data in a plot or a table
Table

List of queried
attributes

1 dimension plot of
values (dot for each
change)

Plot
135405(1) SED Proprietary 56
Choose the number of plots
and lines/plot
Filter the list of
queried attributes

Choose which
attributes are
displayed

135405(1) SED Proprietary 57


 Press the left mouse button and move the mouse to scroll
the plot
 Press the right mouse button, drag it (a drag box will be
shown) and release. The plot will zoom in to the drag box

 Press the Ctrl key and click the left mouse button to zoom
in
 Press the Ctrl key and click the right mouse button to zoom
out
135405(1) SED Proprietary 58
 Right click on the table to
◦ Copy selected or all rows to the clipboard
◦ Save selected or all rows to a file
◦ Print selected or all rows

135405(1) SED Proprietary 59


135405(1) SED Proprietary 60
 A macro is a series of steps that:
◦ Command devices
◦ Get attributes values
◦ Declare variables and assign them values. Variables can be
used in a device command
◦ Wait
◦ Control execution including If statements and While loops
 You edit a macro in the Macro Editor
 You transfer the macro from the GUI to the server using the
Macro Transfer Window
 You schedule the macro to run using the Macro Scheduler
Window

135405(1) SED Proprietary 61


 Select View | Macro | Editor
 File | New to create a new macro

135405(1) SED Proprietary 62


 Click on the step’s Name column to set the type of step

135405(1) SED Proprietary 63


 For command single device step, pick the device name

 And the command name

135405(1) SED Proprietary 64


 And set the inputs to the command

Click here

And then here

135405(1) SED Proprietary 65


Select a value

Click set

135405(1) SED Proprietary 66


Click OK

135405(1) SED Proprietary 67


135405(1) SED Proprietary 68
 Use the toolbar buttons to:
◦ Delete steps

◦ Add a step above

◦ Add a step below

135405(1) SED Proprietary 69


 You can use variables to get a value for an attribute,
change it and use it in a command
 Use a Command Attribute variable so the type of the
variable will be correct for the command

Set the variable name

Select the device

Select the command

Select the attribute

135405(1) SED Proprietary 70


 Use the Get Single Device Value to get the current value
for the attribute

Select the device

Select the attribute

Select the variable

135405(1) SED Proprietary 71


 Modify the value with an Assignment statement

Select the variable

135405(1) SED Proprietary 72


Edit the expression. The right
hand side of the assignment
statement

Enter the expression. In this case,


increase the attenuation by 2

Click OK

135405(1) SED Proprietary 73


 Use the Command Single Device to set the attribute to the
new value

Select the device name

Select the command name

Edit the attributes


135405(1) SED Proprietary 74
Edit the attribute value

Click Add to add the variable to the expression

135405(1) SED Proprietary 75


Click OK

Click OK
135405(1) SED Proprietary 76
 IF statements allow conditional execution

135405(1) SED Proprietary 77


 Upload the macro to the server

Select Upload

135405(1) SED Proprietary 78


 Schedule the macro

Select Schedule

Click OK

135405(1) SED Proprietary 79


Execution status

Resulting events

135405(1) SED Proprietary 80


135405(1) SED Proprietary 81
 Software runs as a Windows Service (SED System Task
Starter) that starts automatically after boot up.
 Software runs on a pair of redundant servers
 They exchange heartbeat messages over a TCP/IP socket
 Standby goes online if:
◦ Commanded to go online by a user
◦ The online server fails and commands it to go online
◦ No message from the online server and it can ping one of the
Ethernet switches

135405(1) SED Proprietary 82


 Shows the state of the server
software. Only one server for
this system.
 Allows you to:
◦ Shutdown the server software
◦ Start the server software (if it was
shut down from the GUI)

135405(1) SED Proprietary 83


135405(1) SED Proprietary 84
 The Carrier Measurement Subsystem (CMS) is used to
remotely measure uplink and downlink signals.
 Measurements are performed through the GUI or through
the socket interface

135405(1) SED Proprietary 85


135405(1) SED Proprietary 86
 Execution Mode:
◦ Manual
◦ Manual (Remote I/F Enabled)
◦ Auto
 Measurement interval is the period between individual
measurements in automatic mode

135405(1) SED Proprietary 87


 Add/Edit measurement entries on the schedule tab
 Measure flag must be set to yes to measure in auto mode
 In auto mode, measurements are performed in order based
on the index column
 In manual mode, select a row and click execute
measurement
 Setup alarm limits for the EIRP and frequency

135405(1) SED Proprietary 88


 Enter the desired measurement
parameters

135405(1) SED Proprietary 89


 Results for the last measured carrier are displayed on the
schedule tab (auto or manual measurement)

135405(1) SED Proprietary 90


 Results tab shows the last result for each entry in the
measurement parameters table
 Results history tab shows the last 10 measurements

135405(1) SED Proprietary 91


 Similar measurement functionality as the Uplink EIRP
measurements, but there are no alarms raised
◦ Measurement parameters are added to the table in the same
way
◦ Results and results history tab display similar data
 Intended to be used for testing and troubleshooting
 Downlink measurements only

135405(1) SED Proprietary 92


 The frequency
determines the
measurement point
(Band 1 or 2)

135405(1) SED Proprietary 93


 The frequency band to be used for CMS measurements is
determined by these settings.
◦ i.e. For uplink RF measurements, the system will measure the
low band if the frequency is <= the ‘Tx BDC Low Band
Frequency Upper Limit’, and high band otherwise.
135405(1) SED Proprietary 94
 The RF measurement frequency is entered in the CMS
measurement windows, and the Decimator measures the
signal at IF. The translation frequencies for each band are
configured on this screen.

135405(1) SED Proprietary 95


135405(1) SED Proprietary 96
 Each HPA has a ULPC tab
 Nominal attenuation should be set to the normal operating
attenuation level at clear sky conditions
 Maximum output power level will not be exceeded by
automatic ULPC adjustments
 Automatic ULPC adjustments are only made if ULPC
adjustments are active

135405(1) SED Proprietary 97


 Configure the mode to auto during ULPC operation
 Measured signal level value feeds back to the ULPC
controller
 Measured signal level comes from the ACU beacon signal
level.

135405(1) SED Proprietary 98


 Configure the mode
and operational
parameters for ULPC
 Perform a clear sky
calibration
 View the current
status for the open
loop solution
 View the current HPA
status

135405(1) SED Proprietary 99


 Displays the current readings, clear sky signal level, and
the delta from clear sky
 Higher averaging factor will smooth out the receive signal
level. The higher the number, the longer it will take for
ULPC to respond to rain fade.

135405(1) SED Proprietary 100


 Allows you to manually change the clear sky signal level
being used as the reference point for adjustments. This
value is normally updated during a clear sky calibration.

135405(1) SED Proprietary 101


135405(1) SED Proprietary 102
 Installers for software upgrades will be made available on
the SED external file share
(https://cs.sedsystems.ca/pydio)
 GUI Upgrade Installer:
◦ Update_SED_MNC_GUI_3_29_X.exe
◦ Shutdown the GUI; Run the update GUI installer; Restart the
GUI.
 Server Upgrade Installer:
◦ Update_SED_MNC_Server_3_29_X.exe
◦ On the standby server computer: Shutdown the SED Systems
Task Starter service and the GUI if it is running on the server;
Run the update server installer; Restart the SED Systems
Task Starter service and wait for the software to go standby;
Switch the upgraded server online through the GUI.
◦ Repeat these steps on the other server computer.

135405(1) SED Proprietary 103


135405(1) SED Proprietary 104
 Online help is available through the help menu on the GUI
◦ ‘Help contents’ provides general Mon-A-Co information
◦ ‘System specific help contents’ provides details on the India
GXI5 system (i.e. CMS, Uplink Power Control)
 System Administrator’s manuals:
◦ Provide details on activities such as:
 Installing software upgrades
 Re-installing the software on a server computer in the event that a
server computer fails
◦ SED Mon-A-Co System Administrator’s Manual (125097)
◦ Inmarsat India GXI5 Administrator’s Manual (135402)