Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

2ND FLOOR BEAM SCHEDULE

TYPE TYPE
SIZE SIZE
NUMBERS LEFT MIDSPAN RIGHT NUMBERS LEFT MIDSPAN RIGHT

200 200 200 300 300 300


2-16MMØ 2-16MMØ 2-16MMØ 5-16MMØ 3-16MMØ 5-16MMØ
B2-1 200X400 B2-7 300X500

400

350

350

500

500

500
2-16MMØ 2-16MMØ 2-16MMØ
2-16MMØ 2-16MMØ 2-16MMØ
3-16MMØ 5-16MMØ 3-16MMØ

TIES: 10MMØ 2 @ 50MM, 10 @ 100MM, REST @ 160 UP TO MIDSPAN TIES: 10MMØ 2 @ 50MM, 10 @ 100MM, REST @ 160 UP TO MIDSPAN

200 200 200


4-16MMØ 2-16MMØ 4-16MMØ
B2-2 200X400
400

350

350
2-16MMØ 4-16MMØ 2-16MMØ
15.00

2.80 1.50 1.50 1.95 1.05 3.00 0.95 2.25


TIES: 10MMØ 2 @ 50MM, 10 @ 100MM, REST @ 160 UP TO MIDSPAN

250 250 250 B2-3 B2-3 B2-3 B2-3 B2-3

3-16MMØ 3-16MMØ 3-16MMØ


B2-3 250X450
450

450

450

2.90

B2-6

B2-6

B2-6

B2-4
STAIRCASE

4.00
3-16MMØ 3-16MMØ 3-16MMØ

B2-3

B2-3
S2 S2 S2 S2

B2-1
TIES: 10MMØ 2 @ 50MM, 10 @ 90MM, REST @ 160 UP TO MIDSPAN

0.95
S1

8.00

8.00
300 300 300 B2-7 B2-4 B2-5 B2-7

1.70
5-16MMØ 3-16MMØ 5-16MMØ S2 S2
B2-4 300X500
500

500

500

B2-1 B2-1

B2-3

B2-4

B2-3
B2-2

4.00
S2

B2-6
S2 S2

B2-4
3-16MMØ 3-16MMØ 3-16MMØ

2.45
S2 S2

TIES: 10MMØ 2 @ 50MM, 10 @ 100MM, REST @ 160 UP TO MIDSPAN

300 300 300 B2-3 B2-3 B2-3 B2-3 B2-3

5-16MMØ 3-16MMØ 5-16MMØ


B2-5 300X500
500

500

500

2-16MMØ 2-16MMØ 2-16MMØ 2.80 3.00 2.00 1.00 4.20 2.00


3-16MMØ 3-16MMØ 3-16MMØ

15.00
TIES: 10MMØ 2 @ 50MM, 10 @ 100MM, REST @ 160 UP TO MIDSPAN

300 300 300


SECOND FLOOR BEAM PLAN
SCALE: 1 : 1 0 0
5-16MMØ 3-16MMØ 5-16MMØ
B2-6 300X500
500

500

500

3-16MMØ 5-16MMØ 3-16MMØ

TIES: 10MMØ 2 @ 50MM, 10 @ 100MM, REST @ 160 UP TO MIDSPAN

RA 544, ARTICLE 5, SECTION 33


PREPARED BY: SEAL: MISCELLANEOUS PROVISIONS, SPECIFICATION AND OTHER CONTRACT PROJECT TITLE: SHEET CONTENT: CONFORME:
DOCUMENTS.

MAC Structural Designs IT SHALL BE UNLAWFUL FOR ANY PERSON TO ORDER


OR OTHERWISE CAUSE THE CONSTRUCTION, AS SHOWN
and Engineering Services
RECONSTRUCTION, OR ALTERATION OF ANY BUILDING
OR STRUCTURE INTENDED FOR PUBLIC GATHERING OR
ASSEMBLY SUCH AS THEATERS, CINEMATOGRAPHS,
PROPOSED CONSTRUCTION OF
STADIA, CHURCHES OR STRUCTURES OF LIKE NATURE,

ENGR. MARK HEINTJE A. CUANAN


AND ANY OTHER ENGINEERING STRUCTURES
MENTIONED IN SECTION TWO OF THIS ACT UNLESS THE
DESIGNS, PLANS, AND SPECIFICATIONS OF SAME HAVE
TWO-STOREY RESIDENTIAL MRS. WARDA PANONDI
OWNER
BEEN PREPARED UNDER THE RESPONSIBLE CHARGE
Services Offered: Building Designs, CAD Drafting,
Structural Designs and other Engineering Services
CIVIL ENGINEER/STRUCTURAL DESIGNER
OF, AND SIGNED AND SEALED BY A REGISTERED CIVIL
ENGINEER, AND UNLESS THE CONSTRUCTION,
RECONSTRUCTION AND/OR ALTERATION THEREOF ARE
BUILDING SHEET NO. 10
Address: B11, L24, Summerville Subdivision, Lumbia, Cagayan de Oro City PRC: VALIDITY: EXECUTED UNDER THE RESPONSIBLE CHARGE AND
DIRECT SUPERVISION OF A CIVIL ENGINEER. PLANS AND
Mobile No: 09482110174/09352839502
PTR: PLACE: CDOC DESIGNS OF STRUCTURES MUST BE APPROVED AS
LOCATION: BAGUA II, COTABATO CITY, MAGUINDANO
Email: markcuanan@gmail.com
DATE: 11/20/2021 TIN:
PROVIDED BY LAW OR ORDINANCE OF A CITY OR
PROVINCE OR MUNICIPALITY WHERE THE SAID
STRUCTURE IS TO BE CONSTRUCTED. OWNER: MRS. WARDA PANONDI
DRAWING NO. S5