Specification: STAR8000H

SHENZHEN COMEN MEDICAL INSTRUMENT CO.,LTD


Floor7,Block5, 4th Industrial Park of Nanyou, Nanshan District,
Shenzhen City 518052, China
Tel: +86-755-26408879
Fax:+86-755-26431232
Email: info@szcomen.com
Web: www.szcomen.com
Patient Monitor
STAR8000H

Standard configuration: Performance Specifications


ECG, RESP, Dual-Temperature, COMEN SPO2, NIBP, Display: 8.4” color TFT touch screen
Reserved-EtCO2 interface Resolution: 800x600
Optional: Trace: 4 waveforms(MAX)
EtCO2, Nellcor/masimo SpO2, Dual-IBP,Thermal Recorder Indicator: Dual alarm indicator lights
Safety Standards Power indicator light
ISO 13485:2003 approved, CE marking according to Battery indicator light
MDD93/42/EEC QRS beep and alarm sound
Physical Characteristics Operating key sound
Product Size: 242mm×218mm×121mm Interface: Parameter cable interface
Net Weight: 2.8kg AC power input socket
Operation Environment Software upgrade through
working Temperature: 0-40℃ networking port or USB port
Humidity: 15-85% USB port
Power Supply AC100-250V, 50/60Hz RJ45 port
External Power Supply Alarm: User-adjustable High and Low
Rechargeable plug & play battery 3-level Limits ;
Battery Type:
Lithium-ion Prioritized audible and visual alarm
Battery Capacity: 4000mA Network: Connected to Central Monitoring
Battery Recharging Maximum 6.5 hours for charging; System by hardwire/wireless
Time: Recorder: Built-in; thermal array
Battery working time: 3~4 hours for continuous working 2 waveforms
Speed:25mm/s,50mm/s Method Automatic oscillometric
Record width:50mm Work mode: Manual / Automatic/Continuous
Data: Power-off storage Auto measure time: Adjustable(1-480min)
Alarm Event Recall: 500 groups(120hours) Measurement Unit: mmHg / Kpa selectable
Wave Recall: 30 mins Measurement types: Systolic, Diastolic, Mean
NIBP Recall: 2000 groups Range of systolic Adult Mode:40-270mmHg
Trend Graph: 120 hours pressure:
Trend Table: 120 hours Pediatric Mode:40-200mmHg
Respiration Neonate Mode 40-135mmHg
Method: impedance method Range of diastolic Adult Mode:10-215mmHg
RR measurement Adult: 0-120bpm pressure:
range: Pediatric Mode:10-150mmHg
Pediatric/Neonate: 0 -150bpm Neonate Mode 10-100mmHg
Resolution: ±1 rpm Range of mean Adult Mode:20-235mmHg
RESP Apnea Alarm: 10s-40s pressure:
Alarm: Audible and visual alarm; alarm Pediatric Mode:20-165mmHg
events recallable Neonate Mode 20-110mmHg
Sweep Speed: 6.25, 12.5, 25mm/s Over-pressure both Hardware and software over
Gain Selection: X0.25, X0.5, X1, X2, X4 protection: pressure protection
ECG Accuracy: Less than ±5mmHg
Lead Type: CardioTecTM ECG Analysis, 5 Lead Resolution 1mmHg
and 3 leadselectable Alarm Systolic, Diastolic, Mean
5-lead cable: RA; LA; RL; LL; V or R; L; N; F; C PR from NIBP: 40-240bpm
3-lead cable: RA; LA; LL or R; L; F Temperature (Dual Channel)
Lead selection: 12-Lead I; II; III; aVR; aVL;aVF; Measurement range: 0-50°C
V1-V6. TEMP sensor: Standard configuration- skin TEMP
5-lead: I; II; III; aVR; aVL sensor,
3-lead: I; II; III Resolution: 0.1°C
Gain Selection: X0.25,X0.25, X0.5, X1, X2,X4, auto Accuracy: ±0.1°C (exclusive of error of sensor)
Sweep Speed: 6.25,12.5, 25, 50mm/s Channel: T1, T2, TD (Temperature
Heart Rate Range: Adult: 15-300bpm Difference)
Pediatric/Neonate:15-350bpm Nellcor SPO2
Resolution: 1 bpm Measurement & alarm 0~100%
Protection: Withstand 4000VAC/50Hz voltage range:
in isolation; Resolution: 1%
Against electrosurgical interference Accuracy: ±2% (70-100%, MAX-A, MAX-AL,
and defibrillation; MAX-N, MAX-P, MAX-I and
Accuracy: ±1% or ±2bpm (whichever is MAX-FAST sensors);
greater) ±3% (70-100%, D-YS, DS-100A,
Bandwidth : MON Mode:0.5 Hz~40 Hz OXI-A/N and OXI-P/I sensors);
DIA Mode: 0.05Hz~130 Hz 0-69% unspecified
OPE Mode:1 Hz~20 Hz
ST Mode:0.2Hz~40Hz PR Measurement 20~300bpm
STSEGMENT detection: -2.0mV - +2.0Mv (Automatic) Range:
Arrhythmia analysis : Yes Resolution: 1bpm
pacemaker detection: detectable Accuracy: ±3bpm
NIBP Alarm range: 20-250bpm
Masimo SPO2 Resolution 1mmHg
Measurement & alarm 1~100% PR from NIBP: 40-240bpm
range Temperature (Dual Channel)
Resolution: 1% Measurement range: 0-50°C (32 to 122F)
Accuracy: ±2% (70~100%,Ped, non-motion+ Resolution: 0.1°C
±3% (70-100%, Neo, non-motion); Accuracy: ±0.1°C (without probe)
0-69% unspecified Channel: 2 channels, T1, T2, TD
Alarm range 0~100% (Temperature Difference)
Pulse rate: Range: 25~240bpm IBP
Resolution:1bpm Channel 4 channels
Accuracy: ±3bpm(non-motion) Measured Pressure AVP, CVP, PAR, LAP, RAP, ICP
±5bpm(motion) Measurement -10mmHg~300mmHg
Alarm range:25~240bpm Range:
Comen SPO2 Alarm Range: -50mmHg~300mmHg
Measurement & alarm 1~100% Accuracy: ±2% or ±1mmHg, whichever is
range greater
Resolution: 1% EtCO2(Sidestream)
Accuracy: ±2% (70~100%,Ped, non-motion+ CO2 Measurement 0 -150 mm Hg, 0 to 79%, 0 to 20kPa
±3% (70-100%, Neo, non-motion); Range: (at 760mmHg)
0-69% unspecified Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
Alarm range 0~100% ± 5% of reading (41 – 70 mm Hg)
Pulse rate: Range: 20~300bpm ± 8% of reading (71 –100 mm Hg)
Resolution:1bpm ± 10% of reading (101 –150 mm
Accuracy: ±3bpm(non-motion) Hg)
±5bpm(motion) awRR range 0-150rpm
Alarm range:20~250bpm RR accuracy: ±2rpm (0-70rpm)
NIBP ±5rpm (>70rpm)
Method Automatic oscillometric Response time: <240msec (10% to 90%)
Work mode: Manual / Automatic/Continuous Delay time: <2s
Measurement Unit: mmHg / Kpa selectable EtCO2(mainstream)
Measurement types: Systolic, Diastolic, Mean CO2 Measurement 0 -150 mm Hg, 0 to 79%, 0 to 20kPa
Range of systolic Adult Mode:40-270mmHg Range: (at 760mmHg)
pressure: Pediatric Mode:40-200mmHg Accuracy: ± 2 mm Hg (0 – 40 mm Hg)
Neonate Mode 40-135mmHg ± 5% of reading (41 – 70 mm Hg)
Range of diastolic Adult Mode:10-215mmHg ± 8% of reading (71 –100 mm Hg)
pressure: Pediatric Mode:10-150mmHg ± 10% of reading (101 –150 mm
Neonate Mode 10-100mmHg Hg)
Range of mean Adult Mode:20-235mmHg awRR range 0-150rpm
pressure: Pediatric Mode:20-165mmHg awRR precision ±2rpm (0-70rpm)
Neonate Mode 20-110mmHg ±5rpm (>70rpm)
Over-pressure both Hardware and software over Delay time: <2s
protection: pressure protection *Notice: Specifications subject to changes without prior
Accuracy: Less than ±5mmHg notice. All rights reserved by Comen