Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Unveiling the Future

We’ve set the bar 2018


for complete control
and now we’re raising it.
FW Murphy Production Controls creates
the next generation of control with the
Production
CENTURION C5 TM 2009
Centurion PLUS
With this groundbreaking release, you are in control. with customizable
options released
• Diagnostics that reduce troubleshooting
• Significant product enhancements
• World-class certifications and harmonized international standards
• Future-proof and backward compatible
• All non-incendive inputs

CENTURION C5
Will change the way you look at asset management.

2004
Centurion
Introduced

w w w. f w m u r p h y. c o m
C5-1 MAIN I/O MODULE MV-5-C M-VIEW TM DISPLAY MODULE WITH GRAPHICAL LCD
Operating Temperature: • -40° to 185° F (-40° to 85° C) Operating Temperature: • -40° to 185° F (-40° to 85° C)

Standard offers a user-configurable experience. Screen: • 320x240 pixels, LCD display with backlight.
Centurion PLUS option offers highly customized applications.
Application Firmware: Integrate with Rockwell Automation Processors as • 12-key user interface keypad set point entry, alarm
User Interface:
I/O module to write IEC 61131-3 logic (Ladder Logic, acknowledgment, start, stop, reset.
Structured Text, Function Block Diagram.) All I/O options
• Serial: RS232-1/RS485-1.
individually software selectable. No jumpers required.
· Protocol: MODBUS RTU (master).
• Serial: RS485-2.
12 Analog Inputs∆: • 0-24 mA or 0-5 VDC, 15-bit hardware.
· Protocol: MODBUS RTU (slave).
• 4 resistive potentiometer measurement. Communications:
• 1 USB slave type B (firmware updates).
• Optically isolated DC digital inputs, (active high/ • 1 USB host type A (reserved).
active low) with LED Indicators. • CAN x 2.
• Polarity sense / wire fault detection on · 1 Proprietary for FW Murphy Hardware.
32 Digital Inputs∆:
normally closed systems. · 1 Reserved for J1939 Engine ECU.
• Approved for use with general purpose switches in
hazardous areas. • Line by line.
Customizable Process Screens: • Gauge.
• J or K Type Thermocouples, 3-wire • Control loop.
100Ω Pt RTD temperature inputs. • Generic register.
8 Temperature inputs∆:
• Open, Short DC-, Short DC+ wire fault detection.
• Digital Input Status and Polarity.
• Cold junction compensation.
• Digital Output Status.
• Temperature Input Status/Fault.
1 Magnetic Pickup Input/AC Run Signal: • 30 Hz to 10 kHz, 4.5 VAC rms min, 120 VAC rms max. Built In Screens:
• Fault Snapshot (mirror of line by line).
• LED indicators. • Alarm Log.
• 4 relay outputs, form C, dry contacts. • Event Log.
10 Digital Outputs:
• 4 FET outputs (source).
• 2 FET outputs (sink).
M-VIEW TM TOUCH DISPLAY
4 Analog Outputs: • 4-20 mA, 16 bit hardware.
Operating Temperature: • -4° to 140° F (-20° to 60° C)
• Serial: RS232 x 2.
Power Input: • 10-30VDC
· Protocol: MODBUS RTU (slave).
• Serial: RS485 x 2. • M-View Touch 7-7” Widescreen 800x480 pixels.
· Protocol: MODBUS RTU (slave).
Screen (sunlight readable): • M-View Touch 10-10.4” 640x480 pixels.
• 1 USB slave type B (firmware updates).
• 1 USB host type A (data log access, firmware updates). • M-View Touch 12-12” Widescreen1280x800 pixels.
Up to 11 Communication Ports:
• CAN x 2. Release date TBD.
· 1 Proprietary for FW Murphy Hardware.
· 1 Reserved for J1939 Engine ECU. User Interface: • Resistive Analog Touchscreen.
• Ethernet x 2 10/100 (DLR).
• 2x RS232
· Protocol: Modbus TCP/IP (slave).
• 1x RS485
· EtherNet/IP (CIP).
Communication Interfaces: • 2x USB host type A (file transfer, datalogging, USB device)
• WIFI x 1 (optional).
• 1x USB slave (program/firmware updates)
• 2 Ethernet 10/100Base TX (RJ45)

EXPANSION I/O MODULES • EtherNet/IP (CIP).


Communication Protocols: • Modbus TCP/IP.
Operating Temperature (All MX Models): • -40° to 185° F (-40° to 85° C)
• Modbus RTU standard.
• 300+ available, Web server.
• 24*∆Digital Inputs: optically isolated DC digital inputs,
(active high/active low) non-incendive with polarity
• Class I, Division 2
sense/wire fault detection on normally closed systems.
• ATEX Zone 2.
• 8 std. config./ 10*∆ analog inputs: 0-24 mA or 3rd Party Approvals:
• IECEx Zone 2, IP66 (face).
MX5-R2 Expansion I/O Module: 0-5 VDC, 15 bit hardware. • Type 4X (face).
• 6 std. config./ 16*∆ digital outputs: open collector • Outdoor (face).
transistor, 150 mA (sink).
• 4 analog outputs: 4-20 mA, 16 bit hardware.
• 1 magnetic pickup input∆ /AC Run Signal: 4.5 VAC - * Applies only to CenturionTM Plus and Rockwell Automation® Processor configurations.
∆ Non-incendive.
120 VAC, 30 Hz to 10 kHz.

• 18∆ J or K Type Thermocouples/9, 3-wire 100Ω Pt


RTD temperature inputs.
• Open, Short DC-, Short DC+ wire fault detection.
• Cold junction compensation.
MX4-R2 Expansion I/O Module:
• 1 magnetic pickup input /AC Run Signal: 4.5 VAC -
120 VAC, 30 Hz to 10 kHz.
1715044 03-18 Printed in the USA

FW MURPHY PRODUCTION CONTROLS DOMESTIC SALES & SUPPORT INTERNATIONAL SALES & SUPPORT
SALES, SERVICES & ACCOUNTING FW MURPHY PRODUCTS CHINA
5417 S. 122ND E. AVE. PHONE: 918 317 4100 PHONE: +86 571 8788 6060
TULSA, OK 74146 EMAIL: INFO@FWMURPHY.COM EMAIL: APSALES@FWMURPHY.COM
WWW.FWMURPHY.COM
CONTROL SYSTEMS & SERVICES LATIN AMERICA & CARIBBEAN
105 RANDON DYER ROAD FW MURPHY CONTROL SYSTEMS & SERVICES PHONE: +1 918 317 2500
ROSENBERG, TX 77471 PHONE: 281 633 4500 EMAIL: LASALES@FWMURPHY.COM
EMAIL: CSS–SOLUTIONS@FWMURPHY.COM SOUTH KOREA
MANUFACTURING
5757 FARINON DRIVE PHONE: +82 70 7951 4100
EMAIL: SKOREASALES@FWMURPHY.COM
SAN ANTONIO, TX 78249

You might also like