Manual Baumer+Series+OF10 V2 EN
Manual Baumer+Series+OF10 V2 EN
2.
LIGHT SOURCE
OBJECT
Features
www.baumer.com 1
Programming
The response time, AUTOSET function, output configuration, and other features can be tailored to
your unique application. Follow the programming procedure contained in this section.
(Status Screen)
Tap MODE ( ) again to access first parameter. Continue tapping to select desired parameter. Use
the threshold/value ADJUST ROCKER ( ) to select or adjust a specific parameter.
AUTOSET Modes
The sensor’s automatic threshold adjustment is controlled by the AUTOSET mode. Each AUTOSET mode
sets the threshold differently. Select the mode that works best for your specific application. See details at
the left.
AUTOSET Mode: Light-State (LS): Sets threshold below received light beam intensity.
Light State LS
AUTOSET Mode: Dark-State (DS): Sets threshold above received light beam intensity.
Dark State DS
Select AUTOSET Mode: Midpoint (MP): Sets threshold at received light beam intensity.
Midpoint MP
AUTOSET Mode: Two-point (2P): Sets threshold between received light beam intensity two point.
Two-Point 2P
AUTOSET Mode: Dynamic (DY): Sets threshold between received light beam high and low
Dynamic DY intensity.
AUTOSET Mode: Window (WN): Sets two thresholds equally spaced above and below received
Window WN light beam intensity. Received light beam intensity within the window is a valid
detect. Outside the window is not a valid detect.
AUTOSET Percent
For Light State (LS), Dark State (DS), and Window AUTOSET Modes (WN), the offset percentage is
adjustable. AUTOSET Percent determines threshold placement during AUTOSET. Placement is a percentage
of received light beam intensity.
2 www.baumer.com
Using AUTOSET Light State (Default)
Place object to be detected in the worst-case light-state
Figure 1
The thres hold is set auto- condition and press the AUTOSET button. The threshold will
matically bypressing the be set 10%(default) below the received light-beam intensity. Sensing Object Position
The threshold can be altered by tapping up or down on the ON Distance @Autoset
AUTOSET button. There
are six threshold adjust rocker (see Figure 1).
different ways the sensor 10%
Threshold
determines the threshold.
The user first must OFF
determine which
type of setup mode is Background
appropriate for the
application. The simplest Dark State Figure 2
and most common mode Place object to be detected in the worst-case dark-state
we recommend is Light State (LS) setup. It is condition and press the AUTOSET button. The threshold will
used in both beam make and beam break ON Sensing
be set 10%(default) above the received light-beam intensity. Distance Object Position
sensing. When using this mode, the sensor The threshold can be altered by tapping up or down on the @Autoset
will provide the best sensitivity to fine threshold adjust rocker (see Figure 2). 10%
changes in light level or contrast. Threshold
After a performed AUTOSET, the threshold
can be manually altered by tapping up or OFF
down on the threshold adjust rocker.
Note: OLED display will provide intuitive
visual feedback during autosetting. Background
Midpoint Figure 3
Threshold
OFF
Background
Two-Point Figure 4
Background
Dynamic Figure 5
OFF
Background
Window Figure 6
www.baumer.com 3
Detect Mode SENSOR
Sensor output activates or deactivated when received light intensity is over the threshold. Not available
when input function is set to Remote Dark On. LIGHT ON
Detect Mode: Light On (LO): Output activates when received light intensity is over OBJECTS
Select Light On LO the threshold. Note: In window mode (WN) output activates when
received light intensity is inside the window thresholds. SENSOR
DARK ON
Detect Mode: Dark On (DO): Output deactivates when received light intensity is over
Dark On DO the threshold. Note: In window mode (WN) output activates when OBJECTS
received light intensity is outside the window thresholds.
Response Time: High-Speed (HS): Fast response time with higher sensitivity (125us).
High-Speed Not available in Asynchronous Anti-Crosstalk Mode.
Select Response Time: Standard (STD): Good balance of response time and range for general
Standard purpose sensing (250us).
Response Time: Long-Range (LR): General purpose sensing with improved range
Long-Range (4ms).
Best
Ultra-Long-Range (ULR): Special purpose sensing with maximum
Response Time:
sensitivity and range (16ms).
Resolution
Ultra-Long-Range
Hysteresis
To avoid false triggers for example due to object vibration. Adjusts the span between the operate point
and the release point of the sensor output. Low hysteresis increases sensitivity and high hysteresis
Most Sensitve Most Stable
increases sensing stability.
Hysteresis: Low (H0): Reduced hysteresis for increased sensitivity.
Low H0
Select Standard (H1): Automatic adjustment depending on signal level.
Sensing Sensing Sensing
Hysteresis: Distance Distance Distance
Standard H1 ON Hysteresis ON ON
Distance
OFF Hysteresis
Hysteresis: High (H2): Increased hysteresis for increased stability. Distance
Hysteresis
High H2 OFF
Distance
OFF
}
A
Channel A xA Assign one sensor to channel A and the
Async Crosstalk: other to channel B.
Channel B xB B A B
4 www.baumer.com
PRESS Timer/Counter Function #: Timer Duration Counter
Choose from 19 pre-configured timer/counter control functions. ADJUST On Delay: ADJUST Count:
Each one represents a function such as on-delay, off-delay, 10ms 0005
etc. Once a function is selected, adjustable parameters of that
function appear such as delay time.
0.1 - 9.9, 10 - 9999ms 0001-9999
Hold up or down to scroll. Hold up or down to scroll.
00 10 ON
Input OFF
Timer Func: 00 Timer not used. Timer Func: 10 Events
Bypass Off, Latch Output Reset Required
"OFF" Latched
“OFF” Delay then Latch Delay
01 ON
Input OFF
11 Input OFF
ON
ON
02 Input OFF 12 ON
Input OFF
Events
Timer Func: 02 Timer Func: 12 Events
Off-Delay Output Delayed One-Shot Output
"OFF" "OFF" "OFF"
One- One- One-
“OFF” Delay Pulse Stretcher Delay Delay Delay One-Shot Delay, then One-Shot Delay Shot Delay Shot Delay Shot
03 ON
Input OFF 13 Input
ON
OFF
Timer Func: 03 Events Timer Func: 13 Events
One-Shot Output Delayed Latch Output Reset Required
One- One- One- Delay Latched
One-Shot Shot Shot Shot One-Shot Delay, then Latch
Select
04 ON
Input OFF
14 Input
ON
OFF
Timer Func: 04 Events Timer Func: 14 Events
Motion Stop, One-Shot
Output Output
One Shot One Shot Retriggerable One-
Motion Detection Triggered Retriggered Triggered Stop Motion, then One-Shot One-Shot Shot
05 15
ON ON
Input OFF
Input OFF Events
Timer Func: 05 Events Timer Func: 15
Latch Reset Required
Stop, Latch Output Requires Reset
Output Retriggerable
Latched
Latching, Edge Triggered Latched Stop Motion, then Latch One-Shot
ON
06 Input
ON
OFF
16 Input OFF
Events
Timer Func: 06 Events Timer Func: 16
On, Off-Delay Output
Latch, On-Delay Output
Reset Required
ON
07 ON
Input OFF
17 Input OFF
Events
Timer Func: 07 Events Timer Func: 17
On, One-Shot Output Latch, One-Shot Output
One- Note:
"ON" One-Shot Shot Output will not occur again
“ON” Delay, then One-Shot Delay Latch, then One-Shot until Reset applied to Latch
1 2 3 4 0 1 2
08 ON
Input OFF 18 Input
Timer Func: 08 Events Timer Func: 18 Events
On, Latch Output
Reset Required Count, One-Shot Output One-Shot
"ON" Latched One-Shot output occurs on the Nth
“ON” Delay then Latch Delay Count, One-Shot detection. For this example N = 5.
09 ON
Input OFF
19 1 2 3 4 5 6 7
Input
Timer Func: 09 Events Timer Func: 00 Events
Off, One-Shot Count, Latch Output Reset Required
Output
"OFF" One- Latch occurs on Nth detection. Latched
“OFF” Delay then One-Shot Delay Shot Count, Latch For this example N = 5.
www.baumer.com 5
Input Functions
Select input to be performed:
Input Function: Disabled: To ignore unwanted signals.
Disabled
Input Function: Remote set: An AUTOSET function is performed when input wire is transitioned from idle to
Remote Set active and returned. Note: input wire can be used in addition to the AUTOSET button.
Select Input Function: Remote command: Sensor parameters can be adjusted via defined pulses. See chart on
Remote Command page 7.
Input Function: Interrogate: Sensor output is latched when input wire is transitioned from idle to active.
Interrogate
Input Function: Gate: Sensing is gated. Detection is enabled when input is active.
Gate
Input Function: Remote Dark On: Detect Mode is determined by input state. Dark On mode is used when
Remote Dark On input is active.
Input Function: Remote Lockout: Remote lock of the AUTOSET, up and down adjust and most mode
Remote Lockout functions.
Display Mode Selects between numeric and percentage modes and flips orientation.
FIBER CABLE
Select
Display Mode:
Numeric 04095 00016
04095 00016
FIBER CABLE
Display Mode:
Percentage 99.9% 01.0% 99.0% 01.0%
CABLE FIBER
Display Mode:
Percentage 01.0% 99.9% 01.0% 99.0%
AUTOSET MODE Light-State Other options: Dark-State, Midpoint Two-point, Dynamic, Window
RESPONSE TIME Standard Other options: Ultra-High-Speed, High-Speed, High-Resolution, Long-Range, Ultra-Long-Range
INPUT FUNCTIONS Disabled Other options: Remote Set, Remote Command, Interrogate, Gate, Remote Dark On, Remote Lockout
DISPLAY MODE Numeric Other options: Percentage, Numeric Flipped, Percentage Flipped
Factory Reset
Hold down MODE ( ) on power up, then tap up or down ( ).
Sensor will return to all settings to factory default (see chart above).
6 www.baumer.com
Remote Command Setting Option Icon Pulse Notes
Sequence
Programming A single pulse initiates AUTOSET.
AUTOSET 1
An additional pulse command is
In Remote Command Mode a limited set of options required to complete AUTOSET for
two-point and dynamic modes.
can be configured via the input wire. This is
accomplished by sending a simple sequence of pulses AUTOSET Mode Light-State LS 2 - 1 - 1
on Q2 (white wire). For example, sending a sequence
of two pulses followed by three pulse followed by two Dark-State DS 2 - 1 - 2
pulses selects dark on mode. Midpoint MP 2 - 1 - 3
Example of 2 - 3 - 3 pulse command Two-Point 2P 2 - 1 - 4
Active
Dynamic Set DY 2 - 1 - 5
P P
Window WN 2 - 1 - 6
Idle D D
Delay Delay AUTOSET Percent 1% 01% 2 - 2 - 1 Percentage will affect the
Pulse width (P) is 40ms - 400ms. next Light, Dark AUTOSET.
2% 02% 2 - 2 - 2
The delay between sets of pulses (D) is 0.75 - 5 seconds.
5% 05% 2 - 2 - 3 Immediate effect on
Pulses are displayed while being received. Valid Window Size
10% 10% 2 - 2 - 4
commands are executed immediately. Holding the
input active will cancel a partial command. 20% 20% 2 - 2 - 5
50% 50% 2 - 2 - 6
AUTOSET Detect Mode Light On LO 2 - 3 - 1
www.baumer.com 7
Specifications
dimension drawing
mm
mechanical data
width / diameter 10 mm
height / length 27,8 mm
depth 93,1
type rectangular
housing material polycarbonate
connection type connector M8 4 pin or cable 2m
ambient conditions
operating temperature +5…+55°C
protection class IP 50
8 www.baumer.com