P - 6c OVER

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

5 50(150)

250 x 10 PL
NO
RE OR
200 x 10 PL
TF
FE CO3c BRICKWORK OVER
MAXIMUM OPENING (mm)
TILED ROOF
5300
METAL ROOF
6200
200 x 10 PL
5 50(150)

6c BRICKWORK OVER 4900 5500

300 END BEARING


RE NS 200 x 10 PL
MAXIMUM OPENING (mm)
TILED ROOF METAL ROOF
3c BRICKWORK OVER 4700 5400
NC TR 6c BRICKWORK OVER 4400 4900

250 END BEARING


E O UC
5 50(150)
150 x 10 PL
NL TIO
200 x 10 PL
MAXIMUM OPENING (mm)
Y N 3c BRICKWORK OVER
TILED ROOF
3700
METAL ROOF
4200
6c BRICKWORK OVER 3500 3800

150 END BEARING

T - LINTELS

NOTES :
1. T-LINTELS SUITABLE FOR OPENINGS WITH UP TO 6 COURSES OF DOUBLE
LEAF BRICKWORK OVER AND SUPPORTING UP TO 3m OF TILED ROOF OR
METAL DECK AND CEILING.
2. PLACE 2L6 GALVANIZED HARD DRAWN WIRES IN THE FIRST TWO BED
JOINTS OF EACH LEAF FOR LINTELS OVER 4.8m LONG. LAP 500mm AND
ENSURE 20mm OF SIDE COVER.
3. ALL WELDING TO AS 4100 - STEEL STRUCTURES CODE.
4. REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE FOLLOWING STANDARDS;
L INDICATES PLAIN OR DEFORMED WIRE R500L OR D500L TO AS/NZS 4671.
ALL STEELWORK TO BE TREATED IN ACCORDANCE WITH CLAUSE 3.4.4.4 "CORROSION
PROTECTION" OF THE BUILDING CODE OF AUSTRALIA.
5. BOTTOM FLANGE TO BE 180 x 10PL AT 190 BRICKWORK LOCATIONS. DATE MODIFIED: 23/12/14
PROJECT :
P
FOR
XX REFERENCE ONLY
CLIENT :
FOR
XX REFERENCE ONLY
Zemla Pty. Ltd. (ABN: 71 349 772 837) ATF the Young Purich and Higham
Unit Trust trading as Structerre Consulting Engineers
SCALE 1:20 APPROVED
1 ERINDALE ROAD, BALCATTA W.A. 6021
TEL (08) 9205 4500 FAX (08) 9205 4541 EMAIL: perth@structerre.com.au DATE N/A
DD/MM/YY
© COPYRIGHT STRUCTERRE CONSULTING GROUP - DEC'05