RELEVANT SWITCHES ARE

150 mm BELOW MOUNTED ON THE SLAB BY 150 mm BELOW


CEILING LEVEL FLOOR BOX CEILING LEVEL
(COORDINATE WITH (COORDINATE WITH
THE AC SUPPLIER) THE AC SUPPLIER)
eq eq 500 500 FFMDB AC Y1 500 500 RSDB AC R4 600
FFMDB AC R1 FFMDB AC B1 RSDB AC Y4

FFMDB AC Y2 FFMDB AC B2 RSDB S B4


NET

1350
RSDB S B4
FFMDB S R2 FFMDB S R4 FFMDB S R5

2025

2025

2025
FFMDB S R1 FFMDB S R4
RSDB S B4

eq
PJ

T
NET
RSDB S Y5 RSDB S Y5 RSDB S Y5
FFMDB S R1

NET

NET
NET

NET
PJ
PJ RSDB S B1 RSDB AC R3
RSDB S Y5
NET NET NET

eq
TO BE RSDB S Y5 RSDB S Y5 RSDB S Y5
FFMDB S R2 FFMDB S R5 T
DISCUSSED FFMDB S R4 FFMDB S R4 eq eq 500 RSDB AC B2 RSDB S B4
AT SITE 2571
3571 RSDB S B2
4571 600
DB

RSDB S B1
RSDB S B2
300 eq eq
1350

300
RSDB S B2
FFMDB S R1 RSDB S B5
RSDB AC Y2

RSDB S Y2
300 300

NET
NET RSDB AC Y3
FFMDB AC R2 NET
RSDB S B5

eq eq RSDB S Y2 RSDB S Y2 RSDB AC B1


RSDB S B2

NET

NET

NET
NET

NET

NET
NET

FFMDB S Y2 FFMDB S Y2 FFMDB S Y2 150 mm BELOW


FFMDB S Y2 FFMDB S Y2 CEILING LEVEL
FFMDB S R1 FFMDB S Y2
(COORDINATE WITH
600

RSDB AC Y1 RSDB S B2 THE AC SUPPLIER)

NET
5450
2200 RSDB S Y2 300

600
RSDB S R1

600
NET

NET

NET
NET

NET

NET
FFMDB S B1 FFMDB S B1 RSDB S Y2 4200

750
FFMDB S Y4
FFMDB S Y4 FFMDB S Y5 FFMDB S Y5 2200

NET
FFMDB S Y4 FFMDB S Y4 FFMDB S Y5 FFMDB S Y5

NET
NET

NET

NET
RSDB S R5
NET

NET

NET
FFMDB S B1 FFMDB S B1 RSDB AC R2 NET NET
RSDB S R4 RSDB S R4

NET

NET
5190
2115
RSDB S R5 RSDB S R5 3837
1837 300 RSDB S R1

NET

NET
RSDB S R2 RSDB S R2

5590

1500
RSDB AC B3
5375

5375
NET

NET

NET

NET

5330
NET

NET

NET

NET
NET NET
FFMDB S B5 FFMDB S B5 FFMDB S B4 FFMDB S B4 300

4800
FFMDB S Y1

NET

NET
FFMDB S Y1 RSDB S R1
FFMDB S B2 FFMDB S B2
RSDB S R4 RSDB S R4
RSDB S R2

3900
RSDB S Y1 RSDB S Y1
FFMDB S Y1 FFMDB S B5 FFMDB S B2 FFMDB S B2
FFMDB S Y1 NET NET

NET

NET
FFMDB S B4 RSDB AC R1
NET

NET

NET

NET
NET

NET

NET

NET
FFMDB S B5 FFMDB S B4 RSDB S R2

2200
2200
2200

2700
RSDB S Y1 RSDB S Y1
TO BE

2280

2280
2200

NET

NET
RSDB S R4 RSDB S R4 DISCUSSED

1500

1500
AT SITE
2 x 16 A 2P Isolator 2 x 16 A 2P Isolator
2 x 16 A 2P Isolator
FFMDB AC R2 FFMDB AC 2 RSDB AC 1
FFMDB AC 4 RSDB AC 2

DB
FFMDB AC 1 FFMDB AC 3

Xref ..\01. FLOOR PLAN\Floor Plan.dwg

150 mm BELOW RELEVANT SWITCHES ARE 150 mm BELOW 150 mm BELOW RELEVANT SWITCHES ARE 150 mm BELOW
FIRST FLOOR CEILING LEVEL MOUNTED ON THE SLAB BY CEILING LEVEL CEILING LEVEL MOUNTED ON THE SLAB BY CEILING LEVEL
(COORDINATE WITH FLOOR BOX (COORDINATE WITH (COORDINATE WITH FLOOR BOX (COORDINATE WITH
THE AC SUPPLIER) THE AC SUPPLIER) THE AC SUPPLIER) THE AC SUPPLIER)

ALL DIMENSIONS ARE IN MILLIMETERS


ALL DIMENSIONS TO BE CHECKED AT SITE
NO DIMENSIONS TO BE SCALED OFF FROM DRAWINGS ONLY WRITTEN DIMENSIONS TO BE FOLLOWED
IN THE EVENT OF ANY DISCREPANCIES OR DIFFERENCE BETWEEN ANY ARCHITECTURAL DRAWINGS AND STRUCTURAL
DRAWINGS OR OTHER ENGINEERING DRAWINGS OR SITE CONDITIONS OR OTHERWISE IMMEDIATE REFERENCE IS TO
BE MADE TO THE CONSULTANT ARCHITECT FOR CLARIFICATION PRIOR TO EXECUTION OF WORK AT SITE
FOR SIZES, DEPTHS, WIDTHS, REINFORCEMENT DETAILS, CONCRETE GRADE OR ANY OTHER INFORMATION PERTAINING
TO FOUNDATIONS, COLUMNS, BEAMS, SLABS OR ANY OTHER STRUCTURAL COMPONENT, THE PROJECT ENGINEER'S
STRUCTURAL DETAILS AND OTHER INSTRUCTIONS SHOULD BE FOLLOWED WITH THE WRITTEN APPROVAL OF THE
CONSULTANT ARCHITECT AS TO ITS CO-RELATIONSHIP WITH THE ARCHITECTURAL DRAWINGS, WHENEVER A DISPUTE
OR DISCREPANCY MAY ARISE OR COULD EVENTUALLY ARISE.

DRG TYPE - ELECTRICAL


REVISION HISTORY ISSUED FOR APPROVAL
MINUSHI AND CHANDANA WEERARATNE ASSOCIATES CONTRACTOR : PROJECT :
C H A R T E R E D A R C H I T E C T S , I N T E R I O R D E S I G N E R S REV DATE DESCRIPTION DESIGN BY DRAWN BY SCALE
L A N D S C A P E D E S I G N E R S & C O N S U L T I N G E N G I N E E R S ANSELL FINANCE , SUPPLY DRG TITLE; N.T.S.

3 1 1 / 1 0 , N E W K A N D Y R O A D , M A L A B E
AND HR OFFICE - SEEDUWA ELECTRICAL POWER OUTLET LAYOUT CHECKED BY DRG NO DATE
TEL : +94112413446 / +94718175652 / +94785434353 E mail : macwa.architects@gmail.com
SUB TITLE; APPROVED BY JOB NO SHEET SIZE & NO
THIS DRAWING IS THE PROPERTY OF THE AUTHORS AND SHOULD NOT BE USED OR REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF THE ARCHITECT /STRUCTURAL ENGINEER
FIRST FLOOR