Certificate of Calibration Mm Certificate Number: A107803 Issued By: SEAS ieee ae ee Instrumentation & onntsitmentation & —_P.0,Box 127352, Abu Dhabi, United Arab Emirates Pegeaat Customer: China Petroleum Engg & Construction Corporation P.0.Box 127345, : ‘Abu Dhabi-United Arab Emirates Purchase Order Number: Desrpten PHT Tansormer Datarype: ——_FoUNDLEFT Manufacturer; Jiangs Gyan Electric Recelved Date: 22WK-60T-0506 Calibration Date: 13-Jun-2021, 2104032 Due bate: 32-Jun-2022 Identification No: NA Calibrated By: Narayenaswamy Gopalan Work Order No: (2930-1 Temperature: 23.00°C tumidity 45 % RH s are within specifications Calibration Remarks : Instrument Read ‘The calibration was performed with measuring instruments/standards whose values are traceable, directly or indirectly by lerivation with admitted calibration procedures, to standards maintained by the National Physical Laboratory-UK / National Institute of Standards and Technology-USA, or to ather recognized international standard bodies for the realization of physical Unit in line with the International System of Units (SI. The calibrated item has been marked with a calibration label, The user Is Cbliged to have the object recalibrated at appropriate intervals, This report applies only to the item identified and shall not be reproduced, except in full, unless permission for the publication of an approved abstract is obtained in writing from the Calibration organization issuing this report. ‘Standard Used: Description Manufacturer / Model Serial Number Due Date ‘Traceability Precision Calibrator Fluke 726 1092189 28-Jul-24 nist Atlanta Instrumentation & Oilfield Services Co.L.L.C. P.,0.Box : 127352, Abu Dhabi, United Arab Emirates, ‘Tel: + 971 25553301, Fax: + 971 2 5553309 Certificate Number: 107803 D ata Report Page 2072 ‘Test Descriotion Nominal Value Lowerlimit Test Result oper Deviation ‘TEMPERATURE MEASUREMENT Range :0-1000°C CHANNEL 200 °C 199 200 201 000 °c 400 °C 398 400 402 00 °c 600 °c 597 600 603 000 5 1000 °c 995 999" 1005-004." CHANNEL2 200 °C 199 200 201 00 °c 400°C 398 400 402 000 °C | 600 597 600 603 000 * 1000 995 999 1005-001 °C CHANNEL3 , ' 200 199 199 201-001 400°C 398, 399 402 01° 600 597 599 603 001 1000 995 1000 1005 00 °c CHANNELS 200 °C 199 199 201-001 °C 400°C 398, 400 402 000 °C 600 °C 597 600 603 000 °c 3000 °C 995 998 1005 002 °C ‘CHANINELS 200 °C 199 200 201 00 °c 400 398 399 402-001 °C 600 °c 597 599 603 01 °C 1000 °C 995 998 100s -002 °C Ailanta Instrumentation & Oilfield Services Co.LL.C. P.,0.Box : 127352, Abu Dhabi, United Arab Emirates, Tel: + 971 25553301, Fax: + 971 2 5553309 "Roce Cate Certificate Number: 8107803 Data Report es Test Result Uppertimit Deviation ‘Test Description Nominal Value CHANNEL 6 200 199 200 201 400 °c 398, 400 402 600 °c 597 601 603 1000 °C 995 1000 1005 6 CHANNEL CHART RECORDER FUNCTION Checked Checked L ‘TEMPERATURE CONTROL FUNCTION. *** End of Certificate ***** ‘SO cara Cleon at Alianta Instrumentation & Oilfield Services Co.L.L.C. .0.Box : 127352, Abu Dhabi, United Arab Emirates, ‘Tel: + 971 25553301, Fax: + 971 25553309

You might also like