Perkins Engine ATP2000 DIESEL GENSET
Made in UK ISO 9001 : 2015
Dimensions Length (mm) Width (mm) Height (mm) Weight (KG) ATP Gen set is equipped with DSE control-
Close Type 12350 2550 3800 14403 ler, one of the world’s top manufacturers
Open Type 6750 2206 3432 10503 in UK, having over 40 years of excellence,
the most advanced and user friendly con-
ENGINE SPECIFICATIONS LUBRICATION SYSTEM troller.
Engine Make Model PERKINS 4016TAG2A
Oil Filter Type Spin-On Full Flow Low fuel consumption, saving on fuel
No. of Cylinders 16 60º Vee
Total Oil Capacity 237 L spend
form Cycle 4 Stroke
Aspiration Turbocharged
Oil Type API-CH-4 or ACEA E5 Compact and rugged design, saving on
Cooling Method Water cooled AIR SYSTEM transport and storage cost
Governing Type Electronic Cylindrical paper
Air Filter Type pleat Designed to occupy less space considering
Governing Class G2 - ISO 8528 Part 1
Combustion Air Flow critical applications and cities where space
Compression Ratio 13.6:1 132 m3/min is at a premium.
(PRP)
Displacement 61.123 litres
Combustion Air Flow
Bore/Stroke 160 x 190 mm 145 m3/min Low noise and vibration, considering criti-
(ESP)
cal applications where noise level matters
Dynamic Charging Alter- 55 AMP, 24V
Max Air Filter Intake 3.7 kPA
nator
Restriction Easy maintenance and long service inter-
COOLING SYSTEM vals , saving on maintenance cost
Exhaust System
Total Coolant Capacity (L) 316 L
3 Muffler Type Industrial Grade Subject to rigorous tests including load
Cooling Fan Air Flow 2430 m / min acceptance, cooling, vibration and noise
Max. Back Pressure 3.0 kPa
Radiator Fan Load 51 Kw level prior shipment to customer.
0
Exhaust Gas Flow (PRP/ESP) 387 m3/ min
Cooling system design 50 C
Exhaust Gas Tempera- < 439 0C Simple to operate and environment friend-
Heat Radiation to Room (PRP) 109 kW
ture ly in worst ambient conditions
Comply with Standards
Equipped with built-in fuel tank sufficient
ISO 3046, BS 5514, DIN 6271, NEMA-MGI, DIN EN, BS 5000, IEC 60034,IEC 60947-2
for 8 to 10 hours of operations.