Professional Documents
Culture Documents
Test Report 06-03-19
Test Report 06-03-19
2018
DEPARTMENT OF CIVIL ENGINEERING
CONCRETE CUBE TEST
Compressive
Size of the
Sl. No Identification Load in (N) strength Remarks
sample in mm
N/mm2
1 150X150X150 NIL 575700 25.59 28 days
2 150X150X150 NIL 562500 25.00 -do-
3 150X150X150 NIL 576800 25.64 -do-
Average 25.41N/mm 2
PRINCIPAL
26.11.2018
DEPARTMENT OF CIVIL ENGINEERING
CONCRETE CUBE TEST
Compressive
Size of the
Sl. No Identification Load in (N) strength Remarks
sample in mm
N/mm2
1 150X150X150 NIL 343400 15.26 7 days
2 150X150X150 NIL 342300 15.21 -do-
3 150X150X150 NIL 355400 15.79 -do-
Average 15.42 N/mm2
PRINCIPAL
14.11.2018
14.11.2018
14.11.2018
PRINCIPAL
14.11.2018
TEST RESULT
Cumulative Cumulative
Percentage of
IS sieve size BIS limits Weight percentage of percentage of
Weight
retained Weight Weight
Retained
retained passing
10 mm 100 - - - 100
4.75 mm 90-100 200 5.0 5.0 95.0
2.36 mm 60-95 1500 29.0 34.0 66.0
1.18 mm 30-70 1600 31.0 65.0 35.0
600 µ 15-34 850 18.0 83.0 17.0
300 µ 5-20 600 11.0 94.0 6.0
150 µ 0-10 250 6.0 100 0
PRINCIPAL
14.11.2018
DEPARTMENT OF CIVIL ENGINEERING
SIEVE ANALYSIS OF COARSE AGGREGATES
TEST RESULT
Cumulative
Percentage of Cumulative
IS sieve size BIS limits Weight percentage of
Weight percentage of
retained Weight
Retained Weight passing
retained
40 mm 100 - - - 100
20 mm 95-100 1150 4.60 4.60 95.4
10 mm 30-70 10700 42.80 47.60 52.6
4.75 mm 10-35 12650 50.6 98.00 20.0
2.36 mm 0-5 500 2.00 100 0
RESULTS:
PRINCIPAL
14.11.2018
DEPARTMENT OF CIVIL ENGINEERING
PHYSICAL TEST ON CEMENT
Normal Consistency : 35 %
PRINCIPAL
14.11.2018
DEPARTMENT OF CIVIL ENGINEERING
SIEVE ANALYSIS OF COARSE AGGREGATES
PRINCIPAL
20.09.2018
PRINCIPAL
22.10.2018
Mix : M20Grade
PRINCIPAL
19.07.2018
TEST ON WATER
PRINCIPAL
19.07.2018
BRICKS TEST
PRINCIPAL
19.07.2018
PRINCIPAL
19.07.2018
TEST RESULT
Cumulative Cumulative
Percentage of
IS sieve size BIS limits Weight percentage of percentage of
Weight
retained Weight Weight
Retained
retained passing
10 mm 100 - - - 100
4.75 mm 90-100 200 5.0 5.0 95.0
2.36 mm 60-95 1500 29.0 34.0 66.0
1.18 mm 30-70 1600 31.0 65.0 35.0
600 µ 15-34 850 18.0 83.0 17.0
300 µ 5-20 600 11.0 94.0 6.0
150 µ 0-10 250 6.0 100 0
PRINCIPAL
19.07.2018
TEST RESULT
Cumulative Cumulative
Percentage of
IS sieve size BIS limits Weight percentage of percentage of
Weight
retained Weight Weight
Retained
retained passing
40 mm 100 - - - 100
20 mm 95-100 1150 4.60 4.60 95.4
10 mm 30-70 10700 42.80 47.60 52.6
4.75 mm 10-35 12650 50.6 98.00 20.0
2.36 mm 0-5 500 2.00 100 0
RESULTS:
PRINCIPAL
19.07.2018
Specimen
Proof stress in Yield stress % of
Sl.No Specimen size in mm weight in Kg
Kg/mm2 in Kg/mm2 Elongation
for 1m
1. 8 mm 1. 468 585 21.1 0.398
2. 470 588 21.2 0.396
3. 467 586 21.5 0.397
2. 10 mm 1. 458 584 22.7 0.606
2. 462 580 21.5 0.611
3. 464 586 22.0 0.620
3. 12 mm 1. 454 559 23.0 0.884
2. 460 565 23.2 0.890
3. 470 575 23.3 0.895
4. 16 mm 1. 455 568 22.7 1.980
2. 460 555 22.1 1.990
3. 465 560 21.7 1.940
5. 20 mm 1. 453 542 23.4 2.400
2. 458 545 23.0 2.460
3. 460 548 23.2 2.480
6. 25 mm 1. 441 584 21.6 3.842
2. 450 588 21.8 3.860
3. 455 592 22.0 3.820
PRINCIPAL