96M12739 Laser warning and explanation labels

    X
    X
    X
    X
    X  -
    X

    6    7
    5
   1    4
    3
    2
   1
    2
   1     E
    D
   O
    M

Related titles


    P
    S
    I
    D

All-Purpose Laser Sensor


Laser warning and
explanation label

LR-TB5000 Series
Laser emission
point

Laser warning and explanation labels


Instruction Manual
• Attached to the cable
Read this manual before using the product in order to achieve maximum performance. Class 2 (English) Class1
Keep this manual in a safe place after reading it so that it can be used at any time.

The following symbols alert you to important messages. Be sure to read these
messages carefully.

It indicates a hazardous situation which, if not avoided, could result in


WARNING
death or serious injury.
It indicates a situation which, if not avoided, could result in product
NOTICE 
damage as well as property damage.

• Included with the product


1 Introduction
Class 2 (included with the product in each language)

Safety Information for LR-TB Series

• This product is only intended to detect object(s). Do not use this


product for the purpose to protect a human body or part of a human * For a Class 2 laser product, select from the warning and explanation labels included
body. in the package the appropriate warning and explanation label according to the coun-
• This product is not intended for use as an explosion-proof product. try and region where the Class 2 laser product will be used. Then, affix the warning
WARNING
Do not use this product in a hazardous location and/or potentially and explanation label over top of the existing warning and explanation label on the
explosive atmosphere. product.
• This product uses DC power. The product may explode or burn if an
AC voltage is applied.
• Do not wire the cable along with power lines or high-tension lines, Precautions on Regulations and Standards
as the sensor may malfunction or be damaged due to noise.
• When using a commercially available switching regulator, ground CSA Certificate
NOTICE  the frame ground terminal and ground terminal.
LR-TB series complies with the following CSA and UL standards and has been certified by
• Do not use this product outdoors or in a location in which its
CSA (Class 2252 06 / Class 2252 86).
light-receiving surface will come in direct contact with stray ambient
• Applicable standard: CAN/CSA C22.2 No.61010-1
light.
UL61010-1
• Use the following power supply.
CSA/UL certified power supply that provides Class 2 output as defined in the CEC
Safety Precautions on Laser Product (Canadian Electrical Code) and NEC (National Electrical Code), or CSA/UL certified power
This product uses a semiconductor laser as its light source. supply that has been evaluated as a Limited Power Source as defined in CAN/ CSA-C22.2
No. 60950-1/UL60950-1
No. 60950 1/UL60950 1
• Use of controls or adjustments or performance of procedures other • Use this product at the altitude of 2000 m or less.
than those specified herein may result in hazardous radiation • Use this product at the level of overvoltage category I.
exposure. • Use this product at pollution degree 3.
• Follow the instructions mentioned in this manual. Otherwise, injury • Indoor use only.
to the human body (eyes and skin) may result.
• Laser emission from this product is not automatically stopped when
it is disassembled. Do not disassemble this product. CE Marking
• Precautions on Class 2 Laser Product
Related titles Keyence Corporation has confirmed that this product complies with the essential


- Do not stare into the direct or specularly reflected beam.
requirements of the applicable EC Directive, based on the following specifications.
WARNING - Do not direct the beam at people or into areas where people
Be sure to consider the following specifications when using this product in a member state
might be present.
of the European Union.
- Be careful of the path of the laser beam.
If there is a possibility that the operator may be exposed to the EMC Directive (2004/108/EC)
specular or diffuse reflections, block the beam by installing a • Applicable standard EMI : EN60947-5-2, Class A
protective enclosure. EMS : EN60947-5-2
- Install this product so that the path of the laser beam is not as the
same height as that of human eye. Low-voltage Directive (2006/95/EC)
• Precautions on Class 1 Laser Product • Applicable standard: EN61010-1, EN60825-1
- Do not stare into the direct or specularly reflected beam. • Use the power supply that has been evaluated as a Limited Power Source as defined in
IEC60950-1/EN60950-1.
• Use this product at the altitude of 2000 m or less.
Item Description • Use this product at the level of overvoltage category I.
LR-TB5000 • Use this product at pollution degree 3.
Model LR-TB5000CL • Indoor use only
LR-TB5000C
Wavelength 660 nm
Pulse width 4.3 ns Remarks: These specifications do not give any guarantee that the end-product with this
product incorporated complies with the essential requirements of the EMC
FDA(CDRH) Laser class* Class 2 laser product Class 1 laser product
Directive.
Part1040.10 Output 1.0 mW 390 μW The manufacturer of the end-product is solely responsible for the complianc e of
Laser class Class 2 laser product Class 1 laser product the end-product itself according to the EMC Directive.
JIS C 6802/ 
IEC 60825-1 Output 1.0 mW 390 μW

* The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in


accordance with the requirements of Laser Notice No.50.

1
 

Package Contents Part Functions


• M ain un it
• Instruction manual Indicator [SET] Button
Output 1 ON : Orange* The operation of this button varies
Related titles
• Laser warning and explanation labels (LR-TB5000/LR-TB5000C only)


Output 1 OFF: Green* depending on the detection mode
Error : Flashing red ( page 5).
* The indicator flashes when two conditions below Example: 2-point calibration
Specifications are met; 1. Press this button with no workpiece
• Stability output turns ON ( page 10). present.
• Output 1 turns OFF when output logic is N.O. or 2. Press this button with a workpiece
Cable LR-TB5000 - turns ON when output logic is N.C. present.
Model Cable with
LR-TB5000C LR-TB5000CL
connector M12
XX-XXXX
Detectable distance*1 60 to 5000 mm
1

Spot diameter Variable (use a spot diameter of 40 mm or less)


2 1567
1234
1 ms/10 ms/25 ms/  2 ms/20 ms/50 ms/  DISP MODE

Response time 100 ms/1000 ms 200 ms/2000 ms


selectable selectable
Type Red laser (660 nm)
[DISP/ ] Button [MODE/ ] Button
Light source Class 2 laser product Class 1 laser product  Pressed for 1 second or less:  Pressed for 1 second or less:

Laser class IEC60825-1,FDA(CDRH) IEC60825-1,FDA(CDRH) Changes the setting value ( page 7) Changes the setting value ( page 7)
Part1040.10*2 Part1040.10*2  Held for 3 seconds or more:  Held for 3 seconds or more:

Switches to the display screen ( page Switches to the setting screen ( page
Mutual interference prevention 8) 9)
4 units (when using the interference prevention function)
function
Timer OFF/OFF delay/ON delay/One-shot For a more detailed explanation, see "Switching between Display Screens" (page 8).
Power voltage 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Current consumption 50 mA or less (without load) *3
NPN open collector/PNP open collector selectable 2 Installation and Wiring
Control output 30 VDC or less, 50 mA or less,
Residual voltage: 2 V or less, N.O./N.C. selectable
Transmission OFF / Tuning /
Reference surface update selectable Installation
Short-circuit current: 1 mA or less for both NPN and PNP
External input For the applied voltage, see the wiring diagrams • Tightening torque for the mounting holes: 1.5 N·m (M4 screw)
I/O*4*5 ( page 2 in the instruction manual). • If the detecting object has a mirrored surface, install the sensor in a position where
For the input times, see the time charts specular reflection will not penetrate the optical receiver.
( page 4 in the instruction manual).
Current output / Voltage output selectable
Current output: 4 to 20 mA with a max. load resistance Wiring
Analog output of 500 Ω
You're ReadingWith
athePreview
Voltage output: 0 to 10 V with an external load resistance
LR-TB Series, you can select the functions of the I/O wires (black and white) from
the combinations shown below during the initial settings. "3 Initial Settings" (page 3)
of 5 kΩ or more
Independently isolate any I/O wires that you will not use.
Upload
Protection against reverse power your documents
connection, to download.
Protection circuit power supply surges, output overcurrent, output surge,
and reverse output connection
Load (input device)  Analog current or voltage input device
Enclosure rating IP65/IP67 (IEC60529)
OR
Amb ient li ght In cand es cent lamp /S un li gh t: 10000 0 l ux or less
Ambient
-20 to +55°C (no freezing)
  Out1+Out2
temperature
Environmental
Become a Scribd member forNPN
full access. Your PNP
eco e a Sc bd e be  oNPN
ull access. ou   PNP
resistance Ambient humidity 35 to 85%RH (no condensation)
Shock resi stance
first 30 days are free.
1000m/s 2 in X, Y, Z axis directions respectively 6 times 1, brown 1, brown
20 ... 30 V 20 ... 30 V
10 to 55 Hz Double amplitude 1.5 mm in the X, Y, Z axis
Vibration resistance 4, black 4, black
directions respectively, 2 hours
Continue for Free
Case: Zinc die cast (Nickel chrome plating), Indicator cover 2, white 2, white
and buttons: PES, Lens cover and display: PMMA
(scratch-resistant coating specifications),
Related titles
Material 3, blue 3, blue


Cable bushing: PBT, Cable: PVC, 0V 0V
M12 connector (only for the cable with connector M12 type):
TPE, PBT, Nickel-plated brass
Cable type: Approx. 200 g (Including cable)
Weight
Cable with connector M12 type: Approx. 160 g   Input+Out1
*1 The range for displayable distance is from 50 to 5200.   NPN   PNP
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in
accordance with the requirements of Laser Notice No.50. 1, brown 1, brown
20 ... 30 V 20 ... 30 V
*3 150mA or less (with load)
*4 You can select the I/O from the following combinations. 4, black 4, black
Control output × 2, control output + external input, control output + analog output,
external input + analog output 2, white 2, white
(For details on the setting method, see page 3 of the instruction manual.)
3, blue 0V 3, blue 0V
*5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported.
You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files
over the Internet, contact your nearest KEYENCE office.

2
 

  Out1+Analog 3 Initial Settings


  NPN   PNP
When you turn on the LR-TB Series for the first time after you purcha se it or when you have
1, brown 1, brown initialized the LR-TB Series, the following initial settings must be configured.
20 ... 30 V 20 ... 30 V
Related titles 4, black


4, black Display Units

2, white 2, white and Press for 3 seconds or more

3, blue 0V 3, blue 0V mm
Start Config.
inch
feet

  Input+Analog
3-1. I/O Select I/O Out1+Out2
  NPN   PNP Selection Input+Out1
Out1+Out2
( page 4) Out1+Analog
1, brown 1, brown
20 ... 30 V 20 ... 30 V Input+Analog

4, black 4, black

2, white 2, white Out1+Out2 Input+Out1 Out1+Analog or Input+Analog

3, blue 0V 3, blue 0V
3-2. External Select Input Laser Off 
Input Selection Laser Off  Tuning
( page 4) DATUM Preset

Adjusting the Spot Diameter

Use the dial on the back of the sensor


to adjust the spot diameter. 3-3. Analog Select Analog
Selection 4 - 20 mA
4 - 20 mA
WIDE
4  NARROW ( page 4) 0 - 10V
5 3

6 2

7 1
8 3-4. Analog  Analog Scaling
9999
Narrow Spot Setting Lower Limit 4 mA = 0 ...
( page 4) 0
WIDE
5
4  NARROW
3
You're Reading a Preview
6 2

7
8
1 Upload your documents to download. 3-4. Analog  Analog Scaling
9999
0 X mm Upper Limit ...
20 mA = 5000
( page 4) 0
NARROW 1 2 3
OR
X (Approx.) 500 1000 2000
Parallel Light Setting

WIDE 4 NARROW Become a Scribd member for full access. Your


Diameter of approx 6 mm
5
4
3
eco e a Sc bd
Diameter of approx. 6 mm
e be o ull access. ou
3-5. NPN/ PNP
6 2 first 30 days are free.
Selection
Select Output
NPN
NPN
7 1 ( page 4) PNP
8

Wide Spot Setting Continue for Free

WIDE
Diameter of approx. 40 mm End Config.
4  NARROW

Related titles


5 3

6 2

7 1
8

0 X mm
1

WIDE 5 6 7 8
2 1234 RUN
500
X (Approx.) 5000 3000 1500 750

• When detecting objects that have holes in them, you can perform stable detection by • After you have finished configuring the initial settings, you will not be able to reconfigure the
making the spot diameter larger. unit, I/O, analog selection, or NPN/PNP selection. To change any of these settings, you will
• Set the spot diameter so that it is 40 mm or less at the desired detecting distance. have to initialize the product . "Initialization" (page 8).

3
 

3-1. I/O Selection 3-4. Analog Lower and Upper Limits


Select from the following table the functions assigned to the I/O wires (black and white). Configure scaling settings, if necessary.

  Current output (4 to 20 mA)


Related titles
Options Black Wire White Wire


Out1 + Out2 Output 1 Output 2   Initial settings   When settings are changed
Input + Out1 External input Output 1 (example)
Out1 + Analog Output 1 Analog output
Analog 4 mA 0 Analog 4 mA 2000
Input + Analog External input* Analog output Analog 20 mA 5000 Analog 20 mA 4000
The functions assigned to output 1, output 2, and external input can be changed after you
finish configuring the initial settings. "6 Detailed Settings" (page 9).
* Would be fixed to transmission OFF. 20.5 mA 20.5 mA
20 mA 20 mA

3-2. External Input Selection


  Transmission OFF [L aser Off]
4 mA 4 mA
The laser beam transmission is stopped. 3.8 mA 3.8 mA

ON
0 50 5000 0 2000 4000
 Input
OFF
Analog 4 mA 4000
Analog 20 mA 2000
Transmission OFF Transmission

20.5 mA
20 mA
< 5 ms < 50 ms

  External Calibration [ Tuning]


When selected, this external input performs the same function as pressing the [SET]
button. 4 mA
3.8 mA

ON

 Input 0 2000 4000


OFF For details on the analog output when an error occurs, see " Output When an Error
Occurs" (page 11).

You're Reading aVoltage


Preview
> 60 ms > 60 ms
output (0 to 10V)
  Reference surface update [DATUM Preset]   Initial settings     When settings are changed
"4 Detection Mode" [page 5]) is set to Upload your documents to download.
When the detection mode ( "DATUM mode," this
(example)
external input updates the reference surface.
Analog 0V 0 Analog 0V 2000
ON Analog 10V 5000 Analog 10V 4000
 Input OR
OFF

> 5 ms Become a Scribd member for10full


V access. Your 10 V
eco e a Sc bd e be o ull access. ou
Updated reference surface first 30 days are free.

< 60 ms Continue for Free


0V 0V
Updated output

Related titles 0 50 5000 0 2000 4000


Response
time Analog 0V 4000
Analog 10V 2000

3-3. Analog Selection


10 V
Select from the following values.
• Current output: 4 to 20 mA
• Voltage output: 0 to 10 V

0V

0 2000 4000

For details on the analog output when an error occurs, see " Output When an Error
Occurs" (page 11).

3-5. NPN/PNP Selection


You can select between NPN outputs or PNP outputs. For details, see "Wiring" (page
2).

4
Related titles


Related titles


You're reading a preview 

Unlock full access (pages 6-11) by


uploading documents or with a
30 day free trial
Continue for Free

Related titles


Related titles


Related titles


Reward Your Curiosity
Everything you want to read.
Anytime. Anywhere. Any device.

Read free for 30 days

No Commitment.
Related titles Cancel anytime.


Share this document
    
You might also like

Document 4 pages

tmp_8479-LR-ZB250AN_AP_IM_96M12305_GB_WW_1014-1b-796519325
Isra Mar
No ratings yet

Document 16 pages

il_065
Eduardo Martinez
No ratings yet

Document 16 pages

il_im_ku
tomasz_nowak9498
No ratings yet
Document 2 pages

PRD-DC_16434
Sarlo11
No ratings yet
Related titles


Document 16 pages

X-LRGB1W_ILDA_V2.pdf
Felipe Lima
No ratings yet

Document 8 pages

datasheetIRM8601S
W Percy Huallpa Calizaya
No ratings yet

Document 6 pages

3005-PR CT Clamp
Khaled Aboul-ELa
No ratings yet

Document 375 pages

sm8100c
MarioFerre
No ratings yet

Related titles


Document 8 pages

Phase Sequence Relays]


sabrahima
No ratings yet

Document 185 pages

ZX Operation Manual (Draft Version) Z157-E1-1


Kritsada Nakthewan
No ratings yet

Document 24 pages

ODW-730-F1+manual+ENG
waynewsh
No ratings yet

Document 8 pages

2126
Pétrus Hoang
No ratings yet
Related titles


Document 7 pages

NHA39411
Eynar Camilo David
No ratings yet

Document 8 pages

ML8511_3-8-13.pdf
Juan Perez
No ratings yet

Document 19 pages

39408,CP25QXVT80 wengler level sensor


Vigneshkumar Jagannathan
No ratings yet

Document 6 pages

377636a_5.pdf
adnene gharssallah
No ratings yet
Related titles


Document 17 pages

Brother Dcp 8080dn 8085dn Mfc 8480dn 8880dn 8890dw Service Manual Free
Clodoaldo Schmitt
No ratings yet

Document 12 pages

PRGE_EM_I-PRGE-12
Nam Phan
No ratings yet

Document 62 pages

Pm100usb Manual
babshuag
No ratings yet

Document 4 pages

pna4601m
Meltem Varol
No ratings yet
Related titles


Document 2 pages

Preventa_Safety_detection_XCSDMP7002_document
AkmalIshak
No ratings yet

Document 5 pages

9e8d88d9c2c114b0
Julio César Elías Rivera
No ratings yet

Document 58 pages

Is 2000 Esa ñ Olman Ul System


Mariano Ariel Rodriguez
No ratings yet

Document 2 pages

iPRD_A9L16563.pdf
cesar1023
No ratings yet
Related titles


Document 6 pages

Tlp
Franz Wagner
No ratings yet

Document 129 pages

Manual Service
mihaimiit
No ratings yet

Document 20 pages

westermo_ug_6643-2213_lynx_lx10-f2g_revn
Cinco Predrag
No ratings yet

Document 2 pages

iPF_A9L15593
peeramohamed
No ratings yet
Related titles


Document 89 pages

Samsung Lcd Ltm295wx


paris68
No ratings yet

Document 35 pages

LaserDoppler Manual
fasantos11
No ratings yet

Document 194 pages

tboxlt2_uk_1.05
Ardeleanu-Simion Stefan
No ratings yet

Document 20 pages

DDW-100+manual+ENG
Robi
No ratings yet
Related titles


Document 38 pages

SRX800_UsersGuide_061515
Christian Velasco
No ratings yet

Document 17 pages

DM50_Quick_Reference
KarthikMeenakshiSundaram
No ratings yet

Document 24 pages

ODW 621 631+Manual+ENG


joaasl
No ratings yet

Document 81 pages

Cognex In-Sight is2000 manual 2017


Cristin Irwin
No ratings yet
Related titles


Document 75 pages

ThorLabs PM100D Manual


picassaa
No ratings yet

Document 9 pages

NDL7910P
Edgar Ernesto Alonso Guadalupe
No ratings yet

Document 18 pages

Sony mvs8000 operation manual


Ivan Petrof
No ratings yet

Document 4 pages

2370957.pdf
hamda
No ratings yet
Related titles


Document 49 pages

EL Series Service Manual (Including EL302Tv)


dav_ob
50% (2)

Document 2 pages

SPD
Andy Neoh
No ratings yet

Document 24 pages

JYF-10B(NEW)-User-Manual
stel stel
No ratings yet

Document 161 pages

xdspd1000
Ricardo Vittorino
No ratings yet
Related titles


Document 35 pages

MultiCubex50 Installation Guide V12 (1)


Norman
No ratings yet

Document 232 pages

LNS4051DX_XAA_SVM
etrsserhjhlj
No ratings yet

Document 48 pages

01 AMT2500 Operating Manual 03212012


Phan Quan
No ratings yet

Document 128 pages

UTD4000 Four-channel English User Manual V1.01


i_aordaz
No ratings yet
Related titles


Document 5 pages

DTCFM5000W_Rev5.0.pdf
Tato Yudayana
No ratings yet

Document 282 pages

P140 OG
Gaurang Patel
No ratings yet

Document 22 pages

COGNEX DM360 Quick Reference


TanCheeSiong
No ratings yet

Document 29 pages

Power Meter E51C2


atereñone
No ratings yet
Related titles


Document 8 pages

N161
Nguyễn Thanh Quang
No ratings yet

Document 4 pages

difuso_AllenBradley
y0o0o0
No ratings yet

Document 19 pages

Two Colours System f


Riccardo Suzzi
No ratings yet

Document 5 pages

DIG out
Rusdian Hasbi Ridho
No ratings yet
Related titles


Document 6 pages

Osisense Xm Xmlk010b2c21
Luis Angel Tasayco Barrios
No ratings yet

Document 38 pages

D550_manual_05-0304_rev5_eng
Cairo Oil Refining Co.
No ratings yet

Ebook 104 pages

Analog Dialogue Volume 46, Number 1


Analog Dialogue
No ratings yet

Ebook 389 pages

Newnes TV and Video Engineer's Pocket Book


Eugene Trundle
No ratings yet
Related titles


About Support Legal Social

About Scribd Help / FAQ Terms Instagram

Press Accessibility Privacy Twitter

Our blog Purchase help Copyright Facebook

Join our team! AdChoices Cookie Preferences Pinterest

Contact us Publishers Do not sell or share my


personal information
Invite friends

Gifts

Scribd for enterprise

Get our free apps

Audiobooks • Books • Documents • Magazines • Podcasts • Sheet music • Snapshots

Language: English

Copyright © 2023 Scribd Inc.

You might also like