Sub Structure Ananya

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

500

TIE BEAM

300
550
250 250
== ==
250 3 NOS. 16 T 3 NOS. 16 T
==
2 NOS. 12 T ALTH. ALTH. 500
ALTH. PEDESTAL -P1
2L-8T@ 150 C/C 2L-8T@ 150 C/C

450
8T-LINKS @ 150 C/C 600x400

500
2L-8T@ 150 C/C

300

850
75 75 75 75
75 75 [ 4 NOS. PER SET +
1 NO LINKS ] 8T-LINKS @ 150 C/C

1500
650
[ 4 NOS. PER SET ] 10T@ 150 C/C
18 NOS. 12 T
2 NOS. 12 T

50
3 NOS. 16 T 14 NOS. 12T
375 ALTH. 3 NOS. 16 T
375 ALTH.
== == 375 ALTH.
== TYPICAL DETAIL OF PEDESTAL

500
TYP.
300

450
TYP. DETAIL OF TB2 (250x300) TYP. DETAIL OF TB1 (250x450) TYP. DETAIL OF TB3 (250x500) MARKED P1 (550x850) TYPICAL DETAIL OF PEDESTAL TYP.

300
MARKED P2 (500x650)

TYP.
300
16T@ 150 C/C 16T@ 150 C/C
80 MICRON POLYTHENE SHEET
COMPACTED WITH RUBBISH
& SILVER SAND MIX
2500
==
TYPICAL DETAIL OF ISOLATED FOOTING
MARKED F2 (2500x3000)

8T@ 150 C/C

1500
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

300
TYP.
F2 300 TYP.

300
200
A
C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1
C2 P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) C2
P-2(300X500) P-2(300X500)
10T@ 150 C/C
F2
80 MICRON POLYTHENE SHEET
COMPACTED WITH RUBBISH
& SILVER SAND MIX
TB-3

750

TYPICAL DETAIL OF ISOLATED FOOTING


MARKED F1 (750x750)

B C2 C2
P-2(300X500) P-2(300X500)
F2 F2

1. ALL DIMENSIONS ARE IN MM. UNLESS OTHERWISE


MENTIONED.
C2 2. SUPER STRUCTURE : SUPER STRUCTURE SHALL BE
P-2(300X500)
OF AUTOCLAVED AERATED CONCRETE (A.A.C.) BLOCK.
F2 F2
3. GRADE OF CONC. M-25, OTHERWISE MENTIONED
C C2 4. ALL MATERIALS SHALL CONFORM TO RELEVANT I.S CODES.
P-2(300X500)
5. FOR STEEL GRADE Fe 500 AS PER I.S 1786-1979.
6. LAPS, SPLICES & BOND LENGTH SHOULD BE 50 D
WHERE `D' IS THE SMALLEST BAR DIA.
7. FOUNDATION & PLINTH : BRICKWORK IN FOUNDATION
AND PLINTH SHALL BE OF 1ST CLASSBRICK IN
C2 1:6 CEMENT MORTAR.
P-2(300X500)
8. ALL DISTRIBUTION BARS ARE 8 TOR @ 200 C/C AND TO BE
F2 F2
PROVIDED WHEREVER REQUIRED
C2 9. ALL SPACER BARS ARE 25 TOR @ 300 C/C AND TO BE
D
P-2(300X500)
PROVIDED WHEREVER REQUIRED
10. MINIMUM CLEAR COVER TO MAIN REINFORCEMENT IS
AS FOLLOWS:
MEMBER TOP BOTTOM SIDE
a. FOUNDATION 50 50 50
b. COLUMN & R.C.C. WALL -- -- 40
F2 F2 c. TIE BEAM 50 50 50
d. BEAM 30 30 30
E C2 C2
P-2(300X500) P-2(300X500) e. SLAB & WAIST SLAB 25 25 25

REV ZONE DESCRIPTION APPD DATE


STRUCTURAL ENGINEER :
POSEIDON ENGINEERING SERVICES
F2 58F, HINDUSTAN PARK, GARIAHAT
KOLKATA - 700029
E-Mail : poseidon.engineering2014@gmail.com
P-2(300X500)
F C2
C2 C1 C1 TB-1
C1 C1 C1 C1 C1 TB-1 C1 C1 C1 C1 C1 C1 C1 C1 GLOSTER LIMITED
TB-2
TB-2

TB-2

P-2(300X500) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400) P-1(600X400)
TB-1 TB-1 F2 ANANYA
G
F1
F1 F1
S.C.-1(250X250) S.C.-1(250X250) NEW WAREHOUSE AREA LAYOUT
UP TO TIE BEAM LVL. S.C.-1(250X250)
UP TO TIE BEAM LVL.
UP TO TIE BEAM LVL. FOUNDATION & BASE PLATE LAYOUT DRG. NO.
SCALE 1:100 2022/17/GLOSTER/NEW WAREHOUSE AREA/ST-01 0 01 OF 03

STATUS TENDER APPROVAL IFC

You might also like