Professional Documents
Culture Documents
VRF York
VRF York
The YORK® line of VRF Air Conditioning System includes a wide range of sizes to meet most
any customer’s needs. Each model is designed to provide comfort and efficiency, in an easy-to-
operate unit and flexible installation makes them an easy fit for a variety of applications. Models
meet the highest energy efficiency ratings, so less energy is consumed without sacrificing comfort
and performance. Each unit is engineered for quiet operation. And, wired or wireless remote
controllers make changing comfort control settings easy with the touch of a button.
2
FEATURES AND BENEFITS
3
ROBUST & RELIABLE DESIGN
Performance Tested
• Capability
• Safety
• 500 hours salt spray
• 6 hours rain
• 130% over match
• 1000m pipe length & 110m drop
• EMC
Reliability Tested
• Tests during fabrication include:
Parts, Leakage, Operation and Safety
• Tests before packing include:
Visual, Function, Capacity, Acoustic test and Accessories
• Backup operation
If one outdoor unit malfunctions, other units continue to operate without stopping the whole system.
• Balance operation
Outdoor units start in turn to balance operation time.
1 2 3 3 1 2 3
2 1
4
FLEXIBLE SYSTEM SOLUTION
Capacity kBtu/h 5.1 7.5 9.5 12.3 15.3 17.0 19.1 24.2 27.3 30.7 38.2 47.7 55 77.1 95.5 Free mix of versatile indoor units
Product Family
Capacity kW 1.5 2.2 2.8 3.6 4.5 5.0 5.6 7.1 8.0 9.0 11.2 14.0 16 22.6 28.0
Over 100 models to complement many
Slim Low Static Pressure
different room designs.
X X X X X X
Duct 185mm (0/30Pa)
X X X X X X X X X X X X
High Static Pressure Duct
(100/196Pa)
X X
Mini Cassette X X X X X X
High Wall X X X X X X X X
Console X X X X X X
Floor Ceiling X X X X X X X X X
X
Fresh Air Unit
X X
TR 7.2 8.2 9.9 11.8 13.3 14.6 16.4 18.1 20 21.7 23.6 24.9 26.5 27.8 29.6 31.1 32.8
Capacity
Cooling kW 25.4 28.9 34.8 41.5 46.4 51.5 57.8 63.7 70.4 76.3 83 87.9 93 97.9 104.2 109.3 115.6
Heating kW 28.1 32.4 37.9 45.8 51.1 57.2 63.7 70.1 73.9 83.7 91.6 96.9 103.0 108.3 114.8 120.9 127.4
Appearance
HP 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72
TR 34.5 36.4 39.8 40 41.1 42.8 44.28 46 47.5 49.3 50.9 52.8 54.5 56.4 58.1 60
Capacity
Cooling kW 121.5 128.2 140 140.8 144.5 150.6 155.7 162 167.1 173.4 179.3 186 191.9 198.6 204.5 211.2
Heating kW 133.8 137.6 153.8 147.8 160.2 165.9 172 178.5 184.6 191.1 197.5 201.3 207.7 211.5 217.9 221.7
Appearance
5
FLEXIBLE SYSTEM & EASY INSTALLATION
Easy Transportation
The outdoor unit occupies a space of 0.97m2. It can be
placed on elevators, saving installation cost and time. It
also eliminates the need for an external crane.
720
mm 0.97㎡
1350mm
Easy Placement
• Total 1000m liquid refrigerant piping length
• Max 190m refrigerant piping length for single pipe
• Recommended 50m height drop when outdoor unit is above indoor unit
• Recommended 40m height drop when outdoor unit is below indoor unit
• Max 110m height drop when outdoor unit is above indoor unit
• Max 90m height drop when outdoor unit is below indoor unit
• Max 30m height drop between indoor units under same outdoor unit
• *If you wish to install VRF system in the place with level difference exceeding recommended values, please contact
local sales office for piping design recommended values.
Flexible Combinations
• Up to 64 indoor units can be connected to
a single refrigerant cycle
• Total indoor unit capacity can be 50-130% 110м
of outdoor units
Space saving
6
AHU CONNECTION KIT
Features
• 0-10V signal from DDC controller(Field supplied)
• Supply (from DDC) or Return air temperature control
• Connect up to 3 integration AHU kits per system for larger capacity AHU
• Mode can also be changed with dry contact input (cool, heat)
• Fan speed can be selected by dry contact input(Max. 3 fans speeds :Low/
Medium/High)
• Defrost signal output
Specification
Pipe connection method Flare connection and welding Flare connection and welding Flare connection and welding
7
FLEXIBLE CONTROL MEETS ANY TYPE OF APPLICATION
7
8
DESIGN TO A BETTER WORLD
Temp Comfort
VRF
Inverter System
Setting
Temp
Too cool
Precise Temper
Use of the inve
temperature w
Begin
Cooling Running Timer
9
SPECIFICATION - MINI-VRF OUTDOOR UNIT
Features
• Dual Frequency 50/60Hz
• Side discharge
• Smaller footprint
HP 4 5
Capacity
TR 3.6 4.0
Apperance
Capacity kW 10.5 12
HSPF BTU/(W.h) / /
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
10
SPECIFICATION - MINI-VRF OUTDOOR UNIT
Features
• Side discharge
• Smaller footprint
Capacity HP 3 5 7
Apperance
Nominal Capacity
Electrical Parameter
Performance
Containerization
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
11
SPECIFICATION - MINI-VRF OUTDOOR UNIT
Features
• Dual Frequency 50/60Hz
• Side discharge
• Smaller footprint
HP 8 10 12
Capacity
TR 6.4 8.0 9.5
Apperance
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
12
SPECIFICATION - MODULAR VRF OUTDOOR UNIT 380V
Features
• High performance - EER up to 4.29
• Frequency 50/60Hz
• Top discharge
• Smaller footprint
• Match with versatile indoor units
• Flexible and quick installation
• Quiet operation
• 9 Basic Modular units: 8HP, 10HP, 12HP, 14HP,
16HP,18HP,20HP,22HP,24HP
• Connection of up to 64 indoor units per refrigeration circuit consisting
of 3 outdoor units
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
13
SPECIFICATION - MODULAR VRF OUTDOOR UNIT 380V
Features
• High performance - EER up to 4.29
• Frequency 50/60Hz
• Top discharge
• Smaller footprint
• Match with versatile indoor units
• Flexible and quick installation
• Quiet operation
• 9 Basic Modular units: 8HP, 10HP, 12HP, 14HP,
16HP,18HP,20HP,22HP,24HP
• Connection of up to 64 indoor units per refrigeration circuit
consisting of 3 outdoor units
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
14
CONSOLE
Features
• Compact Design & Small Space Occupation
• Quite Operation
• Air Discharge through Top(Cooling) or Bottom(Heating)
• 6 Models Ranging from 1.5KW to 5.0KW
• Standard wireless controller, Optional wired controller
• 2-way air outlet
• Emergency operation • Flexible
• Quiet operation • Easy installation
• High efficiency filter • Compact unit , space saving
Specification
Performance
Indoor Noise Level dB(A) 45/42/39/35/32 45/42/39/35/32 45/42/39/35/32 47/44/41/38/34 48/45/42/39/35 48/45/42/39/35
External Static Pressure Pa 0 0 0 0 0 0
Indoor Air Flow m3/h 540/460/390/310/270 540/460/390/310/270 540/460/390/310/270 580/500/420/350/270 620/540/460/390/270 620/540/460/390/270
Piping Size Liquid/Gas mm ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7
Containerization
Dimension (WxHxD) mm 700/600/210 700/600/210 700/600/210 700/600/210 700/600/210 700/600/210
Indoor unit Packing (WxHxD) mm 783/695/303 783/695/303 783/695/303 783/695/303 783/695/303 783/695/303
Net/Gross weight kg 15.2/18.7 15.2/18.7 15.2/18.7 15.2/18.7 15.2/18.7 15.2/18.7
Qty per 20’/40’/40’HQ Pieces 174/350/350 174/350/350 174/350/350 174/350/350 174/350/350 174/350/350
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
15
MINI CASSETTE
Features
• Compact design: installation restriction is reduced to enable high flexibility
• Body size 570*570mm, panel size 620*620mm, suitable for standard ceiling
tiles and small rooms
• DC fan motor, low sound level and high efficiency
• Automatic display of faults
• Built-in drain pump and EEV
• Innovative 4 independent air flow control
• Standard wired controller, Optional wireless controller
Specification
Performance
Indoor Noise Level (H/M/L) dB(A) 32/30/29 32/30/29 32/30/29 33/30/29 33/30/29 34/32/30
External Static Pressure Pa 0 0 0 0 0 0
Indoor Air Flow m3/h 650/540/430 700/590/480 700/590/480 700/590/480 700/590/480 700/590/480
Piping Size Liquid/Gas mm ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7 ø6.35 /ø12.7
Containerization
570/260/570 570/260/570 570/260/570 570/260/570 570/260/570 570/260/570
Dimension (WxHxD) mm
620/60/620 620/60/620 620/60/620 620/60/620 620/60/620 620/60/620
Indoor unit 718/380/680 718/380/680 718/380/680 718/380/680 718/380/680 718/380/680
Packing (WxHxD) mm
666/108/681 666/108/681 666/108/681 666/108/681 666/108/681 666/108/681
Net/Gross weight kg 2.8/4.5 2.8/4.5 2.8/4.5 2.8/4.5 2.8/4.5 2.8/4.5
Qty per 20’/40’/40’HQ Pieces 60/130/130 60/130/130 60/130/130 60/130/130 60/130/130 60/130/130
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
16
ONE-WAY CASSETTE
Features
• Hanging-style installation to save space;
• DC fan motor, low sound level and high efficiency;
• Automatic display of faults;
• Built-in drain pump;
• The air conditioner is provided with the function of
compensation for power supply. During operation, when the
power supply fails emergently and resumes again, the air
conditioner returns to the working condition before power
failure, if provided with compensation function. • No need to reserve service port in addition. Remove
• Standard wired controller, optional wireless controller, the return air panel can maintain the units . More
Function of central control (optional); convenient and beautiful;
• The operating methods and functions are same although the • Slim design with the height is only 185mm
shapes of indoor units are different;
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
17
TWO-WAY CASSETTE
Features
• Stylish design
- Seamless integration with any interior decoration
• 280mm height main body
• Quiet operation
• Easy installation
• Built-in water pump with max. 750mm head
• Easy cleaning and maintenance
- Flat type suction grille for easy cleaning
• Wired controller as standard offer, wireless controller optional
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
18
FOUR-WAY CASSETTE
Features
• Compact design
- The height of unit from 240 / 295mm (old) to 183/208/246/288mm,
more slim and more light.
• Reserve fresh air inlet
- Reserve fresh air inlet on the side panel, if necessary, knock off the
fresh air inlet to inlet fresh air.
• Distribute the air flow evenly four way
-High air volume can meet higher lifting requirements, integrated with
the room decoration
• Build in drain pump and EEV
Specification
19
FOUR-WAY CASSETTE
Washable Filter
Washable filter allows for convenient service and
maintenance.
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
20
ROUND WAY CASSETTE
Features
• Automatic display of faults;
• Built-in drain pump;
• The air conditioner is provided with the function of
compensation for power supply. During operation, when
the power supply fails emergently and resumes again, the
air conditioner returns to the working condition before
power failure, if provided with compensation function.
• Standard wired controller, optional wireless controller, • Innovative 4 independent air flow control .
Function of central control (optional); • 6 adjustable louver position, 1296 air flow combination.
• The operating methods and functions are same although • Move eye intelligent system, intelligent all around
the shapes of indoor units are different; (optional).
• Unique round-way air outlet , no blind spot .
Specification
Indoor unit Packing (WxDxH) mm 983/983/268 983/983/268 983/983/268 983/983/268 983/983/268 983/983/290
21
ROUND WAY CASSETTE
Auto restart
Unit is automatically returned to previous operating
conditions after a power outage, for simplified
operation.
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
22
HIGH WALL
Features
• LED display
• Built-in EEV
• Stylish design
• Super quiet operation 2.2-7.1kW
• 3D air flow
• Intelligent air direction control, cooling air goes up and heating
air goes down
• Vitamin C and ESF Filter Optional
• Wireless controller as standard offer, wired controller is
optional
• Without built-in high head drain pump, not available for
external drain pump
8-9kW
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
23
HIGH WALL
ESF Filter
Electrostatic filter with an active carbon layer
traps harmful dust and removes unpleasant
odors, improving air quality and creating a fresh,
comfortable environment. (Optional)
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
24
FLOOR CEILING
Features
• Appearance without screw, easy care
• DC fan motor
• Flexible installation ,on the floor or on the ceiling
• Turbo mode 4.2m(14KW) which is flexible for installation choice
• Left and right swing controlled simultaneously
• Intelligent eye(optional)
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
25
FLOOR CEILING
Washable Filter
Washable filter allows for convenient service and
maintenance.
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
26
SLIM LOW STATIC PRESSURE DUCT
Features
• Ultra thin design saving installation space
- Only 185mm height x 500mm depth
• 0 or 30Pa selectable external static pressure
• Knock down drain pan
- Easy disassembly
- Two side drainage available by changing drain pan direction
• Built-in high head 600mm drain pump
• Concealed installation perfectly matching with indoor room decoration
• Multi-mode installation
- With or without air return duct
- Bottom or rear air return
• Wired controller as standard offer, wireless controller optional
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
27
SLIM LOW STATIC PRESSURE DUCT
50/60 Hz
4 Fan Settings
50Hz and 60Hz, 220-230V power supply supports
Smaller dimensions for easy installation and
regions with unstable voltage, avoids power supply
transportation, and reduces cost.
demand, and saves inventory and transport costs.
Washable Filter
Washable filter allows for convenient service and
maintenance.
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
28
MEDIUM STATIC PRESSURE DUCT
Features
• External drain pump optional for 9.0~14kW
• Free setting of air discharge duct
- Free selection of air flow outlets and installation position
• Wired controller as standard offer, wireless controller optional
Specification (Optional)
Nominal Capacity
Capacity kW 9 11.2 14
Cooling Input W 490 490 490
Current A 2.2 2.2 2.2
Capacity kW 10 12.5 16
Heating Input W 490 490 490
Current A 2.2 2.2 2.2
Motor
Performance
Containerization
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
29
MEDIUM STATIC PRESSURE DUCT
Features
• Slim design, hidden installation, The thinnest shape design, more elegant
• The standard draining pump. The pump is standard , the maximum lift is 700 mm
• Reserve fresh air inlet, more healthy. Fresh air holes are left on the side of the unit
• T-shaped lifting eye, Width and length direction can be adjusted, more convenience
• Automatic display of faults
• Heat retaining pipe liner, made by the EPS material, better sealing
• Same height (248mm) for whole series, save height for the room
• Easy installation
Specification
Model Name YVEVXH015WAR--GY YVEVXH022WAR--GY YVEVXH028WAR--GY YVEVXH036WAR--GY YVEVXH045WAR--GY YVEVXH056WAR--GY
Nominal Capacity
Motor
Performance
Indoor Noise Level dB(A) 39/37/35 39/37/35 39/37/35 39/37/35 39/37/35 40/38/36
External Static Pressure Pa 50~100 50~100 50~100 50~100 50~100 50~100
Indoor Air Flow m /h
3
630/510/424 630/510/424 630/510/424 630/510/424 740/550/442 980/840/760
Piping Size Liquid/Gas mm ø6.35/ø9.52 ø6.35/ø9.52 ø6.35/ø9.52 ø6.35/ø12.7 ø6.35/ø12.7 ø6.35/ø12.7
Containerization
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
30
Washable Filter 4 Fan Settings
Washable filter allows for convenient service and Smaller dimensions for easy installation and
maintenance. transportation, and reduces cost.
Specification (Optional)
Performance
Indoor Noise Level dB(A) 44/41/38 46/42/38 46/42/38 46/43/39 47/44/39
External Static Pressure Pa 50~100 50~100 50~100 50~100 50~100
Indoor Air Flow (H/M/L) m3/h 1174/1080/960 1174/1080/960 1500 1700 2000
Piping Size Liquid/Gas mm ø9.52/ø15.88 ø9.52/ø15.88 ø9.52/ø15.88 ø9.52/ø15.88 ø9.52/ø15.88
Containerization
Dimension (WxDxH) mm 1100/700/248 1100/700/248 1100/700/248 1500/700/248 1500/700/248
Indoor unit Packing (WxDxH) mm 1332/835/280 1332/835/280 1332/835/280 1698/857/305 1698/857/305
Net/Gross weight kg 37/43.6 37/43.6 39.4/45.4 48.3/56.5 51.3/59.5
Qty per 20’/40’/40’HQ Pieces 80/160/160 80/160/160 80/160/160 60/120/120 60/120/120
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
31
HIGH STATIC PRESSURE DUCT
Features
• 5 airflow speed. Meet different needs
• The height is only 248mm, can be hidden installed inside the
ceiling. The form of air supply outlet can be chosen according to
customer’s need.
• Standard DC fan motor, low noise and more efficiency.
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
32
• Standard DC fan motor, the ESP can reach 200Pa (1.5~8kw), flexible air duct design
to meet different room types. The ESP value can be set by a wired controller, more
convenient.
• Standard DC drain pump, the pump head up to 1200mm.
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
33
50/60 Hz
50Hz and 60Hz, 220-230V power supply supports Washable Filter
regions with unstable voltage, avoids power supply Washable filter allows for convenient service and
demand, and saves inventory and transport costs. maintenance.
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
34
FRESH AIR UNIT
Features
• Install with other indoor units together
- Installed capacity must less than 30% of outdoor capacity
• Wired controller as standard offer, wireless controller not optional
• 100Pa static pressure
• Operation ambient temperature -5~43°C
Specification
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
35
BUILD IN FLOOR STANDING
Features
• Automatic display of faults;
• The air conditioner is provided with the function of compensation
for power supply. During operation, when the power supply fails
emergently and resumes again, the air conditioner returns to the
working condition before power failure, if provided with compensation
function.
• Standard wired controller, optional wireless controller, Function of
central control (optional);
• Require very little installation space: only 0.26 m2 .
• Good solution for installation beneath a Window.
• Standard high efficiency filter
Specification
36
50/60 Hz 4 Fan Settings
50Hz and 60Hz, 220-230V power supply supports Smaller dimensions for easy installation and
regions with unstable voltage, avoids power supply transportation, and reduces cost.
demand, and saves inventory and transport costs.
Auto restart
Unit is automatically returned to previous operating
conditions after a power outage, for simplified
operation.
Rating Conditions(AHRI1230):
Outdoor Temperature Indoor Temperature
Cooling: 35oDB/23.9oWB 26.7oDB/19.4oWB
Heating: 8.3oDB/6.1oWB 21.1oDB /15.6oWB
37
HEAT RECOVERY VENTILATOR
Features
• Efficient heat recovery air processing
- Exchange the heat between supplied air and exhausted air,
equalizing the outdoor air to indoor temperature
- Decrease the interior heat load to save energy
• Replaceable heat exchange media
Specification
38
SELECTION SOFTWARE
Function
• Select Outdoors and Indoors based on the
required capacity as well as according to project
specifications
• Provides System Ratings considering Outdoor
design conditions
Indoor Selection
Piping
Final Report
Outputs List
• Material List (Including Indoor And Outdoor Units, Total Pipe
And Wire Length, Total Accessories)
• Room List
• Indoor/Outdoor Matching Table
• Indoor Units And Outdoor Units Details
• Piping And Wiring Diagrams
• Pipe Length & Drop Limitation
• Refrigerant Charging Guide
• Prices for each of the components
39
For more information about VRF Air Conditioning System,
please contact your local Johnson Controls representative.
© 2022 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA GH2VYHASM-220117