Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

KB-500

Radiography X-ray machine

Features
1. 125kV、500mA、Single-phase full-wave voltage rectifier bridge
2. It has X-ray tube capacity protection, rotating anode start protection, photography timing
circuit thyristor controlled and X-ray tube overheat protection, to ensure the long-term
safe operation of X-ray tube.
3. Multifunction radiography table, no earth-track double rope fall protection safety column,
attractive appearance, bed vertical and horizontal movement can be flexible, X-rays of
each component can be moved and transported lightly and flexibly, electromagnetic
brake, and can withstand various loading Specifications radiography cassette.
4. Radiography currents is bigger, offer more options to users
5. Grid Ratio is of 10:1, the bigger, the better image quality

1
Technical Specifications

PARAMETER SPECIFICATION
Power Supply Voltage 380V±10%
capacity ≥30KVA
power ≤0.3Ω
resistance
Generator
Frequency 50Hz±1 Hz
Tube Electricity 100-500mA, adjustable
Radiography Tube Voltage 40-125KV, adjustable
Exposure Time 0.02-5S,23grades,adjustable
X-ray Tube Model XD51.30-50/125kV
Focus 1×1mm/2×2mm

Capacity 140KHU

The anode rated speed 2800r/min

Optional: Electrical: Circuit Three-phase full-wave rectified or DC Operating


X-ray Tube (Center-grounded)
TOSHIBA E7843X Tube Voltage: Radiographic 40 ~ 150 kV Max.
Focal Spot Large Focus 1.2 mm
(IEC60336) Small Focus 0.6 mm
Input Energy Large Focus 46 kW ~ 50 kW
(at 0.1s) Small Focus 20 kW ~ 22 kW
Collimator Manual leafy type rectangular radiation field. Manual, adjustable, has
1-minute timer

Deluxe CDG Size 5"×7",8"×10",10"×12",11"×14",12"×15",


Radiography Table 14"×14",14"×17"
Rate:10:1
Grid density:40L/cm,
Grid
Focusing distance:100cm
Mobile range:≥640mm
Table movement vertical:1280mm,cross:215mm
Around the cross arm:±180°,Around longitudinal
Tube movement
axis rotation±90°,Vertical stroke≥1130mm
The break of the Electromagnetic locking
table
Self rotate :≥180°;Every 90 °
Column movement
positioning;vertical:1500mm

2
Lifting range 1480mm
Radiography 8"×10"~14"×17"
Vertical Bucky Stand Specifications
Fixed grids Convergence distance: 180cm
Grid ratio: 10:1, Grid density: 40L/cm

Standard Configuration
1 set of 5G High voltage transformer components,
1 set of SC3F X-ray tube,
1 KB-500 controller,
1 set of CDG radiography table,
1 YS11S manual collimator,
2 sets of high-voltage cable and other accessories.
1 set of advanced vertical chest stand.

You might also like