Ammonit Wind Farm Monitoring Systems (SCADA)

SCADA wind farm monitoring with Ammonit Meteo-40 data loggers


Once the wind farm is set up and running, its best performance has to be ensured. To do so, it is essential to monitor
and check its operation. Meteo-40 can easily be integrated in SCADA (Supervisory Control and Data Acquisition) sys-
tems to provide reliable comparative meteorological data. Considering the measurement data recorded by Meteo-40,
for example, predictions about the annual energy production of the wind farm can be verified. Meteo-40 records
measurement data, which is used by wind farm operators and investors, as well as for forecasting reasons.

With its configurable Modbus Register Map Meteo-40 is designed for operation in most existing SCADA systems. The
necessary parameters are configured via the user-friendly Meteo-40 web interface.

Advanced technology for convenient operation.

SCADA Server Operation Center

OR

Your advantages of using Ammonit Meteo-40 data loggers for SCADA applications

Ammonit Meteo-40 data loggers are compatible with High accuracy according to industry standard IEEE
most existing SCADA systems. 754 floating-point values.

Communication via Ethernet Configurable Modbus Register


(TCP/IP) or RS485. Map for data retrieval.

Powerful LinuxTM computer for Configurable Modbus Endian-


data interpretation. OR
ness for SCADA server.

Restricted data access for defined IP Intuitive web interface Data transmission via standard proto-
address by Modbus TCP security. for configuration. cols Modbus TCP/IP and Modbus RTU.

measuring wind and solar power www.ammonit.com


Ammonit Wind Farm Monitoring Systems (SCADA)

Convenient implementation of Meteo-40 in your SCADA system


In order to install the data logger in a SCADA system, it has to be connected via RS485 or Ethernet (TCP/IP) to the
wind farm network. Meteo-40 uses the standard protocols Modbus TCP/IP and Modbus RTU for data transmission.
The measurement data can conveniently be retrieved via the Modbus Register Map.
File Edit View Go Bookmarks Tabs Help

Back https://d130080.local/communication/scada/

You can easily enter SCADA details via the Me- Help Logout
(Admin on D130080)

teo-40 web interface. After having selected the Recording: On Switch off SCADA
SCADA protocol and entering the required pa- Configuration:

Connection:
Saved

Ethernet,Tunnel
Save

rameters, the Modbus Register Map has to be Remaining:


Date/time:

2013-08-06 09:52:33 UTC+01:00

configured. System
Activate SCADA server

Information SCADA protocol


Administration
Modbus RTU
Upgrade

Live data of all active channels and switches Display


Web Camera
TCP port
502

as well as statistical data can be accessed. By


Switches
Logbook
Allowed client IP address
Measurement

editing the Modbus register map, you can con- Sensors


Channels Modbus unit id
Evaluation
veniently assign register numbers to each value.
1
Data
RS-485 slave speed
Live

All entries are checked for plausibility. For the Statistics


Source
9600 bps

RS-485 slave data format

SCADA client, only the values with assigned reg- Communication


Schedule
E-Mail
8N1

ister number are available. Online


FTP/SCP
Statistic interval
10 min
SCADA
LAN Save
WLAN
Modem Edit Modbus register map

Edit METEO-32 stream map

中文(简) Englis h Es pañol Português Français Deuts ch Türkçe © 2011-2013 Ammonit Meas urement GmbH
www.ammonit.com

Meteo-40 and Modbus


Measurement values are represented as single precision IEEE 754 floating-point numbers, which are stored in two
subsequent 16-bit Modbus registers. Date/time values, i.e. year, month, day, hour, minute, and second, are repre-
sented as decimal values, which are stored in one 16-bit Modbus register each.

With regard to the editable Modbus register map, live data of all active channels and switches as well as statistical
data can be collected. The following statistics are available:
File Edit View Go Bookmarks Tabs Help

• Average (scalar or vectorial) Back https://d110017.local/helper/modbus

Two Registers (32-bit) Live Avr. StdDev Min. Max. Sum Median
• Minimum System
Information Top level main horizontal anemometer, Wind Speed (m/s) 1 71 281 211 141

• Maximum
Administration
Top level main vane, Wind Direction (°) 17 87 297 227 157
Upgrade
Display Main temperature sensor / hygrometer, Humidity (%) 37 107 317 247 177
• Standard deviation Web Camera
Switches Main temperature sensor / hygrometer, Temperature (°C) 29 99 309 239 169

• Median System Log

Measurement
Main atm. pressure sensor, Air Pressure (mbar)

Main rain gauge, Precipitation (mm)


33 103 313 243 173

111
• Count
Sensors
Channels A7 (V)
Evaluation
A8 (V)
Data
Live A11 (V)

Modbus Endianness for SCADA server Statistics


Source
C1 (I)

You can conveniently configure the Meteo-40 endianness


Communication
Schedule
C9 (I)

D1

via its user-friendly web interface.


E-Mail
Online Int. Voltage (V) 57 127
FTP/SCP
Int. Current (mA)
SCADA
LAN Int. Temperature (°C) 59 129

Modbus register address interpretation


WLAN
Modem One Register (16-bit) Year Month Day Hour Minute Second
Live Date/Time 45 46 47 48 49 50
In order to configure the Meteo-40 register tables, you Statistics Date/Time 115 116 117 118 119 120

only have to define unique register addresses to the se- Switches

lected data.
Modbus byte endianness
Big (most significant first)

Modbus word endianness


Big (most significant first)

Save

User-friendly and to the point for more efficiency. Back to SCADA

© Copyright Ammonit 2013