Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 7

Inquiry Specification of Doc No.

: J20B0083E
Ver.: E
PASSENGER LIFT Page:1/7

Contract No. Equipment No.

Seller: SJEC CORPORATION


Buyer:
Quotation No:
Contract No:
User:
Name of project:
Installation country/city:
Delivery ex works:
Quantity:
Design Reference Standard: EN81-1 EN81-1+A3 EN81-20/EN81-50

Note: Contact SJEC aboutvalidity of certificates, or if there is another standard used in local.
The consulted result must be added to the contract.
Lift Type
Machine Room Less M300 S810 S810-M S820 * Only one type could
be selected on each
Machine Room Above M670 S830 E500 E550 C300 Inquiry form
IBasic specification:
1 Capacity (kg) 630 800 1000 1150 1600 2000
2 Speed (m/s) 1.00 1.50 1.75
3 Drive VVVF Closed Loop
380V(3PH)/220V(1PH) 400V(3PH)/230V(1PH)
4 Power/Lighting voltage:
220V(3PH)/127V(1PH)
5 Frequency: 50HZ 60HZ
Simplex
A A
6 Car Group B B
Group
C C
D D
7 Car Entrances One Two
8 Floors/Stops/Opening / /
9 Serving floors
II Shaft:
1 Shaft construction Concrete Brick with Concrete beams Steel
2 Clear dimensions W mm * D mm
3 Travel mm
4 Pit depth mm
5 Overhead mm
6 Floor to floor distance ≥2700 mm
III Car:
Car Dimensions
1 W *D
(mm*mm)
2 Car clear height (mm) 2200 2300

Author Approve Date 2022-12-27


Inquiry Specification of Doc No.: J20B0083E
Ver.: E
PASSENGER LIFT Page:2/7

Contract No. Equipment No.

One car entrance: Two car entrances:


Center Opening Center Opening
Side Opening ( Left right) Side Opening ( Left Right)
3 Door type
In case of landing door through
opening
Door controlled independently
Door controlled synchronously
4 Dimensions (mm*mm) 800*2100 900*2100 W *H
IV Car Decoration:
1 Car Ceiling Type:
2 Lighting LED
3 Car Flooring Provide ( Type: ) No provide(recess mm)
Provide ( Type: )
4 Handrail No provide Select sides of car (multiple choice)
Left Right Rear
5 Mirror No provide Provide ( Type: )
6 Emergency exit No provide Provide
Paint steel ( Color: )
3-sides walls
Hairline stainless steel
(when single opening)
Mirror stainless steel
2-sides walls Etched stainless steel
(when through opening) (Picture: )
7 Car wall finishing Other Description:
Paint steel ( Color: )
Hairline stainless steel
Mirror stainless steel
Front return
Etched stainless steel
(Picture: )
Other Description:
V Car Door:
1 Door safety *Describe in VIII Functions No.85
Paint steel ( Color: )
2 Door finishing Hairline stainless steel Mirror stainless steel
Etched stainless steel(Picture: )
VI Car Operate Panel:
1 COP quantity One Two
Full height COP ( Hairline ST; Mirror ST)
COB310 ( Hairline ST; Mirror ST)
2 COP face plate
COB650 (Plastic head + Hairline ST)
Option:
Black-white segment LED Blue-white segment LCD
Red Dot-matrix LED 7 inch TFT LCD*
3 Position direction indicator White Dot-matrix LED 10 inch TFT LCD*
*: TFT is available for full-height COP
VII Landing Fixtures:
FOB340 ( Hairline ST; Mirror ST) * Wall mounting type
1 HI&HB face plate FOB310 ( Hairline ST; Mirror ST) Flat inserting type
FOB650 (Plastic head + Hairline ST) Flat inserting type

Author Approve Date 2022-12-27


Inquiry Specification of Doc No.: J20B0083E
Ver.: E
PASSENGER LIFT Page:3/7

Contract No. Equipment No.

FOB700 ( Hairline ST; Mirror ST) Wall mounting type


Other Option:
Black-white segment LED White Dot-matrix LED
Red Dot-matrix LED Blue-white segment LCD
2 Position direction indicator No floor indicator 4.3 inch TFT LCD
*: FOB340 is only available to use Black-white segment LED or
Red Dot-matrix LED
With hall button Above hall doors *
3 Indicator position No floor indicator
*: Above hall doors is available to FOB310 and HOP
4 HB&HI Group control type Single type One for two liftsin group control
5 Hall lantern No provide DZD-1 DZD-2 DZD-3
VIII Control Cabinet: *Only for control cabinet of MRL type. No need to choose for MRA.
Type A Faceplate: Hairline Stainless steel 430
(Faceplate type) * Box: Galvanized steel box
*: Faceplate type Control cabinet shall be inserted into shaft wall.
Faceplate is larger than cabinet by 30mm at each side.
Cabinet Material The thickness of shaft wall shall be at least 240 mm. Both sides
1
(for MRL type) of cabinet shall be enclosed by wall or local decorations.
Full enclosure material:
Type B Paint steel RAL7036
(Full enclosure type) Hairline Stainless steel 430
Hairline Stainless steel 304
IXLanding Door:
Paint steel ( Color: )
1 Panels at main floor Hairline stainless steel Mirror stainless steel
Etched stainless steel(Picture: )
Paint steel ( Color: )
2 Panels at other floors Hairline stainless steel Mirror stainless steel
Etched stainless steel(Picture: )
Standard type Other option
3 Jamb at main floor Paint steel ( Color: )
Hairline stainless steel Mirror stainless steel
Standard type Other option
4 Jamb at other floors Paint steel ( Color: )
Hairline stainless steel Mirror stainless steel

XFunctions:
No Function Std Opt No Function Std Opt
Automatic generation of
1 Direct travel leveling 2
optimum curve
3 Motor auto-tuning 4 Shaft learning
Re-running automatically when
5 6 Floor position auto-correction
elevator is re-powered
Car location adjusted Automatic startup torque
7 8
automatically compensation
9 Running times recording 10 Running hours recording

Author Approve Date 2022-12-27


Inquiry Specification of Doc No.: J20B0083E
Ver.: E
PASSENGER LIFT Page:4/7

Contract No. Equipment No.

11 Over voltage protection 12 Phase trip protection


13 Over current protection 14 Motor over heat protection
15 Encoder trip protection 16 Contactorstuck protection
17 Bidirectional over speed 18 Running direction reversal
protection protection
19 Travel over time protection 20 Final terminal protection
21 Car overload protection 22 Door lock bypassed detection
23 Opposite direction car call 24 Full-load non-stop running
cancelled automatically
Low-speed re-level in case of
25 26 Next floor if open door faults
some fault
27 Warning if stop out of door zone 28 Emergency illumination in car
29 Fault data recording 30 Emergency alarm
31 Automatic car fan 32 Automatic car lighting
33 Fire return feedback 34 Floor number display settable
35 Automatic parking 36 Car fan manually control
Parking floor
nly
37 Attendant Operation choice 38
O
n
Independent running
39 o e 40
Door open holding button in
41 attendant window 42 Car call anti-nuisance
Car call cancelable Automatic by-pass jammed hall
43 44
button
Settable door open time Check door lock bridge before
45 46
Landing doorlock double circuits exit inspection
checked Peak service
47 Landing service upon time 48 Landings
Landings Time
time Security floor
49 50
VIP service Landing
51 Landings: 52 Shaft lighting
Arrival gong on car (proposed) Shaft Plastic
53 54 cable Metal (select in case of
Arrival gong on landing trunk
(customized) steel shaft)
Parking key switch,
55 56
located on Landing:
Remote shutdown interface Fire return by building fire
57 58
Fire return switch (Phase I), system
located on Main landing: Automatic after fire
return
Fireman
59 60 service Key switch in COP
Earthquakedetector (phase II) Key switch on
nominated
floor
Video / Co-axial cable
61 62 other CAT5E network
Audio cable in traveling cable cables in cable
(twisted-pair cable)

Author Approve Date 2022-12-27


Inquiry Specification of Doc No.: J20B0083E
Ver.: E
PASSENGER LIFT Page:5/7

Contract No. Equipment No.

traveling CAT6 network


cable cable
Keypad for 1 set/project Circuit breaker 1 set/project
63 64
commissioning 1 set/lift lock(for MRL lift) 1 set/lift

65 Power saving device


(regenerative driver)
66 UCMP (Unintended car For EN81-1, Travelling height >20m, “Automatic
movement protection) re-leveling” is recommended.
67 Automatic re-leveling For EN81-1+A3 or EN81-20/50, “UCMP” and
68 “Automatic re-leveling” must be selected.
Door pre-opening

No Function Std Opt No Function Std Opt


Rescue for Machine Room Less lift Rescue for Machine Room Above lift
Remote manual brake release Machine room manual brake
70 70
(mechanical) release (mechanical)
ARD, capable of
ARD, capable of
71 71 Only-open-brake mode
Only-open-brake mode
*not available to C300
ARD, capable of Machine-drive ARD, capable of Machine-drive
72 72
mode mode
Provide fan in MRL control panel
73 73 Machine room power box
(N/A for S810-M)
Machine room Plastic
*ARD: Automatic Rescue Device upon power off 74
cable trunk Metal

No Function Remark Opt


EN81-70 package
In Only pr vide installation in erface.
terface for EN81-28 auto-dial system (by local)
Dialing osystem by local. t
onlywith Braille, relief
onlywith Braille, relief, audible signal
Button for disability
with Braille, relief, audible signal, contrast symbol,fully comply
with EN81-70
COP at right side when CO door (when
Disability COP CD-400 (auxiliary) entering car), at closing side when SO
(choose either one) Main COP for disability door, at both right & left sides of car
when CW>1600
English
Voice announcer Other
81
Indicator above hall
doors
Shall
e bc p om liant t wi h Indicator
Hall sons
butto Indicators &
+ll ltern Indicator with hall
position of VII Landing Fixturesand
n butt Ha an No.55 of XFunctions
(recommended arrow type
DZD-2)
Shall be compliant with Handrail of IV
Car Decoration
n u a o tt i
Handrail HC-104
Co tact s bout locati n and quan i y n
compliance with EN81-70.
Mirror (half height) on rear wall Shall be compliant with Mirror of IV Car
(recommended mirror st.st car door and front Decoration
Author Approve Date 2022-12-27
Inquiry Specification of Doc No.: J20B0083E
Ver.: E
PASSENGER LIFT Page:6/7

Contract No. Equipment No.

wall in case of through opening car)

No Function Selective Standard Optional


82 collective Full collective Down collective
Car call controlled synchronously
(swipe card and push button), except
main floor or other exception floor:

Access control Car call controlled independently


83
(Security control) (only swipecard to register floor
without push button), except main
floor or other exception floor:
*if card used for other access
devices, please contact us.
5-terminal interphone

If use center management phone


in monitoring room, please
choose wiring method:
Parallel wiring Series 3-terminal interphone
Interphone wiring (machine room, car, main
floor)
If 2 or more monitoring rooms on Provide by others
a project, please fill lift number of
each monitoring room
84 Room 1:
Room 2:
Room 3:
5-terminal: monitoring room, machine room, car top, car and pit
3-terminal: machine room, car and main floor
If 4 or more lifts share one monitoring room, center management phone will be used in monitoring
room.
In case of 4 to 22 lifts, it will be parallel wiring and each lift should have a cable from control panel
to monitoring room. In case of 23 to 254 lifts, it will be series wiring and all lifts control panel
interphones should be connected into BUS system and then to monitoring room.
Cable from control panel interphone to monitoring room is by others.
Please consult factory regarding cable specification.
85 2D light curtain with safety edges
Door safety device 2D light curtain 3D light curtain
3D light curtain with safety edges
4 dry contact interface*
Remote monitoring RS485 interface*
Remote monitoring system*
4 relays in control panel, can monitor:
4 dry contact interface 1)Elevator status “normal”, “inspection”, “fire return”, “trip”
86 SJEC provide an interface device with 4 relays.
1 RS485 port in control panel, can monitor:
1) Elevator travel direction, current landing,
2) Door status “open”, “close”,
RS485 interface 3) Elevator status “normal”, “inspection”, “fire return” , “trip”, “Attendant”,
“over load”, “full load”, “fire return”, “service off”, “door lock”, “safe loop”
4)Fault code
SJEC provide a RS485 port and protocol document.

Author Approve Date 2022-12-27


Inquiry Specification of Doc No.: J20B0083E
Ver.: E
PASSENGER LIFT Page:7/7

Contract No. Equipment No.

Monitoring system based on RS485 interface. Same monitor information


Remote monitoring as RS485 interface.
system SJEC provide monitoring hardware and monitoring software in PC.
Cables between elevator and monitoring room and PC by customer.

XIOther features:
1 Pit ladder No provide (by other) Provide
2 Car bottom balance weight No provide Provide

3 Installation and Soft copy Hard copy


maintenance manual Please help us to protect the environment.

XIIAdditional item:

Note: If the other functions, please contact us.

Author Approve Date 2022-12-27

You might also like